Home
Triax TSI 003
Contents
1. T 490733 TDH 733 DVB C QAM NIT 120 306 MHz 104 122826 TDS 88 Bulk Ral 7035 100 pcs pll 82 302172 TD 372 226 490742 TDH 742 Master DVB S mono module CI 101 122847 TDS 88 Bulk Ral 8012 100 pcs pll 82 303172 TD 372 226 490743 TDH 743 Master DVB S stereo module Cl 101 122868 TDS 88 Bulk w single Ral 7016 100 pcs pll 82 D ERO 490744 TDH 744 Slave DVB S T mono 103 122823 TDS 88 Bulk w single Ral 7030 100 pes pll SO Bee Se Se E Ee 490745 TDH 745 Slave DVB S T stereo 103 122867 TDS 88 Bulk w single Ral 7035 100 pcs pll SO arg Gene EEAO e Geo 490746 TDH 746 Master DVB S mono module FTA 101 122869 TDS 88 Bulk w single Ral 8012 100 pcs pl 82 Barea block SINE Ge Ge eg swite 7 490747 TDH 747 Master DVB S stereo module FTA 101 12186
2. TYPE TMS 5x4 TMS 5x6 TMS 5x8 TMS 5x12 TMS 5x16 Part No 300314 300316 300318 300312 300317 Number of inputs 4SAT 1 TER 4SAT 1 TER 4SAT 1 TER 4SAT 1TER 4SAT 1TER Subscriber outputs 4 6 8 12 16 Connectors F con female female female female female Frequency range SAT MHz 950 2150 950 2150 950 2150 950 2150 950 2150 Frequency range TER MHz 47 862 47 862 47 862 47 862 47 862 Gain SAT dB 6 5 5 0 D Gain TER dB 4 3 3 4 2 Isolation TER to SAT dB 22 25 25 22 22 Isolation SAT to TER dB 22 28 28 22 22 Isolation cross polarisation H V dB 25 28 28 25 25 Isolation out out TER dB 30 28 28 28 28 Isolation out out SAT dB 30 35 35 35 35 Return loss SAT inputs dB 12 11 11 11 10 Return loss SAT outputs dB 7 9 9 8 8 Return loss TER inputs dB 11 11 11 11 10 Return loss TER outputs dB 7 9 9 8 8 Output level SAT IMD3 35 dB GEUN 100 101 101 100 100 Output level TER IMD3 60 dB GEUN 88 85 85 85 85 Impedance input output Ohm 75 75 75 75 75 Switching VDC 13 V 18V 13 V 22 kHz 18 V 22 kHz Supply voltage VDC 15 0 5 15 0 5 15 0 5 15 0 5 15 0 5 Power supply External power External power External power External power External power adaptor adaptor adaptor adaptor adaptor LNB power supply max mA 600 600 600 600 600 Colourcoding of IF and TER Inputs Yes Yes Yes Yes Yes Temperature range OE 0 55 0 55 0 55 0 55 0 55 Dimensions H x D x W mm 1
3. O ge pO ELIS ELIO 6 U9 9 19 GIS v OUT Technical data on TA multichannel amplifiers with saddle and clamp connectors TA 65 3R TA 65 3R TA 65 3R TA 65 3R TA 65 3R TA 65 3R D E DK DE 1 DK SE 3 DK SE 4 DK 330601 330603 330604 330605 330606 330610 Input 1 Channel Band 23 60 58 30 46 33 43 50 31 53 XX YY Gain dB 8 28 0 20 28 28 28 6 26 Noise figure dB lt 3 0 lt 7 0 lt 4 0 lt 4 5 lt 3 5 lt 3 0 Input 2 Channel Band 33 43 50 52 Rest UHF Rest UHF Rest UHF WW XX YY Gain dB 8 28 0 20 0 20 0 20 0 20 6 26 Noise figure dB lt 3 0 lt 7 0 lt 4 5 lt 55 lt 5 5 lt 3 0 Input 3 Channel Band Rest UHF Rest UHF 9 BIII BIII Rest UHF Gain dB 0 20 5 25 25 0 20 0 20 0 20 Noise figure dB lt 5 0 lt 4 0 lt 4 0 lt 4 0 lt 4 0 lt 5 0 Input 4 Channel Band BI BIll 6 Rest BIll BII FM BII FM BI BIll Gain dB 0 20 5 25 0 20 10 4 10 10 4 10 0 20 Noise figure dB lt 4 0 lt 4 0 lt 6 5 lt 4 0 lt 4 0 lt 4 0 Input 5 Channel Band BII FM BII BII BII FM Gain dB 10 10 5 15 5 15 10 10 Noise figure dB lt 4 0 lt 4 0 lt 4 0 lt 4 0 Max output voltage 60 dB IMA GEUN 110 110 110 110 110 110 Numbers of in output 5 1 5 1 5 1 4 1 4 1 5 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 65 65 65 65 65 65 DC throughpower Switschable Switschable Switschable Switschable Swit
4. TYPE SCT 100 Part No 364100 Numbers of inputs 10 Input requency range MHz 950 2150 Input level dBuV 52 75 Frequency steps MHz 1 LNB feeding voltage V mA 12 250 per input max 500 mA total Spurious emission dBm 63 Intermediate frequency MHz 480 Line output MHz 950 2150 Line output attenuation dB max 3 0 Connections dB F con Impedance Ohm 15 Output basic unit Output frequency range MHz 1000 2150 Frequency steps MHz 1 MHz Oscillator suppression dB gt 20 Spurious emission dB 26 Variable attenuator dB 20 Output level typ dBuV 85 General data Power consumption W max 40 Operation voltage V AC 190 260 Operation temperature range oC O to 50 Weight kg 3 0 Dimensions H x D x W mm 195 x 80 x 280 122 Triax TCC 19 compact cabinet 19 swing rack cabinet providing easy access and excellent overview If more basic units are built together they can conveniently be inserted in Triax s 19 swing rack providing an excellent overview and easy access to all connections and programming units Technical data TCC 19 compact cabinet TYPE TCC 19 cabinet TCC 19 cabinet with glass door with steel door Part No 251493 251494 Colour Grey Ral 7030 Grey Ral 7030 Height outer mm 1100 1100 Width outer mm 650 650 Depth outer mm 450 450 Backboard dimension H x W x D mm 940 x 550 x 16
5. TYPE TMS 2x4C TMS 2x8C Part No 300274 300278 Number of inputs 2 SAT 1 TER 2 SAT 1 TER Subscriber outputs 4 8 Connectors F con female female Frequency range SAT MHz 950 2150 950 2150 Frequency range TER MHz 5 862 5 862 Gain SAT dB 2 2 Noise figure dB 6 6 Insertion loss trunkline SAT dB 3 5 4 0 Isolation trunk to trunk dB 40 40 Isolation LNB to LNB dB 30 30 Isolation cross polarisation H V dB 30 30 Return loss SAT inputs dB 12 12 Return loss SAT outputs dB 12 12 Return loss TAP outputs dB 10 10 Output level IMD3 35 dB GEUN 100 100 Input level IMD3 35 dB GEUN 40 90 40 90 Impedance input output Ohm 75 75 Supply voltage from receiver via subscriber ports V 10 18 10 18 Max current 13 V 18 V mA lt 80 lt 80 Max current to each H V LNB mA lt 500 lt 500 Temperature range oC 20 60 20 60 Dimensions H x D x W mm 136 TMS 55 xx tap Technical data TMS taps and splitter TYPE Part No Expand the TMS 5x series into a cascadable system Triax TMS IF taps and splitters Using TMS 55 taps makes it possible to construct large cascadable systems Different tap values allow fine tuning of available signal levels By using splitters you can balance your distribution system the best possible way TMS 55 12 tap 300313 TMS 55 15 tap 300333 tap 300343 TMS 510 splitter TMS 55 20 TMS 55 24 tap 300353
6. 333227 SCA 2027 amp ch 27 47 153580 Screw 8x 100 mm bag with 50 pcs 73 333500 IA 13 W 1 W 40 333228 SCA 2028 amp ch 28 47 314021 SCS F7000 21 mast filter ch 21 58 333417 TA ZI W 3 way 43 333229 SCA 2029 amp ch 29 47 314022 SCS F7000 22 mast filter ch 22 58 333450 TA 24 BB cascade 43 333230 SCA 2030 amp ch 30 47 314023 SCS F7000 23 mast filter ch 23 58 333466 TA 24 W 24 W 43 333231 SCA 2031 amp ch 31 47 314024 SCS F7000 24 mast filter ch 24 58 333431 TA25A 41 333232 SCA 2032 amp ch 32 47 314025 SCS F7000 25 mast filter ch 25 58 333434 TA 25B 41 333233 SCA 2033 amp ch 33 47 314026 SCS F7000 26 mast filter ch 26 58 333437 TA 25 C D 41 333234 SCA 2034 amp ch 34 47 314027 SCS F7000 27 mast filter ch 27 58 333401 TA25W 41 333235 SCA 2035 amp ch 35 47 314028 SCS F7000 28 mast filter ch 28 58 333501 TA 25 W 1 W 43 333236 SCA 2036 amp ch 36 47 314029 SCS F7000 29 mast filter ch 29 58 333501 TA 25 W 1W 41 333237 SCA 2037 amp ch 37 47 314030 SCS F7000 30 mast filter ch 30 58 333451 TA 30 BB cascade 2 way 43 333238 SCA 2038 amp ch 38 47 314031 SCS F7000 31 mast filter ch 31 58 333432 TA34A 42 333239 SCA 2039 amp ch 39 47 314032 SCS F7000 32 mast filter ch 32 58 333435 TA34B 42 333240 SCA 2040 amp ch 40 47 314033 SCS F7000 33 mast filter ch 33 58 333438 TA 34 C D 42 333241 SCA 2041 amp ch 41 47 314034 SCS F7000 34 mast filter ch 34 58 333402 TA34W 42 333242 SCA 2042 amp ch 42 47 314035 SCS F7000 3
7. 11 Triax band Ill wideband aerial VHF Band Ill aerials are wideband channel or channel group types for horizontal or vertical mounting The aerials are provided with brackets for masts up to O60 mm or with window brackets Channel 5 12 4 elem window Technical data Channel 5 12 10 elem Channel 5 12 6 elem Channel Channel Channel Channel Channel Channel Channel 5 12 5 12 5 12 5 12 5 12 5 12 5 11 104663 106663 103861 103862 104665 104579 100582 Channel 5 12 5 12 5 12 5 12 5 12 5 12 5 11 Band BIII BIII BIII BIII BIII BIII BIII Elements pcs 4 4 4 6 6 10 13 Gain dBi 5 0 5 0 5 0 7 5 15 9 5 11 5 Front to back ratio dB 14 14 14 16 16 22 25 Beamwidth hor deg 34 34 34 26 26 23 18 Windload N 34 34 34 48 48 78 120 Weight kg 0 7 0 7 0 7 0 9 0 9 1 3 3 0 Material Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 852 852 852 1410 1410 1735 3580 width mm 800 800 800 800 800 880 810 Connector SC type SC type F con F con SC type SC type SC type Type MTH MTHV MTHV MTH MTH MTHD MTD Remarks Split beam BIll 6 elem Gain Ch 5 12 eee B a a S E a 11 a A a a BAA EE Ch 5 12 6 elem 12 Ch 5 12 10 elem Ch 5 12 13 elem Triax band I group channel aerial VHF Channel 9 11 5 el
8. TP 3851 TP 3852 601 60B 602 60B P601 100 P602 100 651 350 332303 332304 336106 336121 336362 336363 336350 Band VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Frequency range MHz 47 860 47 860 47 860 47 860 47 860 47 860 47 860 Inputs pcs 1 1 1 1 1 1 1 Outputs pcs 1 2 1 2 1 2 1 Through loss dB 0 5 4 0 1 0 4 0 1 0 4 0 1 0 1 5 Voltage V DC 12 24 24 24 24 24 24 Max power mA DC 85 85 60 60 100 60 350 Main voltage V AC 230 230 230 230 230 230 230 Power W 2 6 2 6 4 0 4 0 8 0 8 0 15 0 Connectors S amp C S amp C F con F con F con F con F con Certification Ce CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 75 Weight kg 0 2 0 2 0 25 0 25 0 25 0 25 Dimensions h x d x w mm 69x55x94 69x55x94 90x48x115 9 90x48x115 90x48x115 90x48x115 Remarks 199 Triax KOKA cable for indoor use KOKA 100 is a HiQ universal coaxial cable for TV broadcast in house cabling The low attenuation the optimised shielding and the high return loss predestine the cable for use of both SAT IF SMATV and CATV with returnpath applications Transfer impedance less than 5 mQ m 5 30 MHz Technical data on KOKA 100 HiQ and 80 indoor cable KOKA 100 KOKA 80 Double shielded Double shielded White Grey White Grey PVC ESYA g PVC L EZK Part No Coil 100 m 150180 150160 Reel 100 m 1
9. TDD 110 Tap TDR 200 Splitter 364060 364050 Number of inputs 4 x SAT 4 x SAT Number of outputs 4 x SAT 2 pcs 4 x SAT Number of taps 4x SAT Connectors F con female female Frequency range Pass through MHz 470 2200 Tap MHz 950 2200 950 2200 Through loss dB 2 0 1 Tap loss dB 10 0 1 6 0 1 Isolation dB gt 20 gt 16 Isolation tap dB gt 35 gt 35 Impedance Ohm 75 75 Return loss dB gt 6 dB min 10 dB typ gt 6 dB min 10 dB typ Return loss trunk dB On Off switch for DC pass Yes Yes Power supply voltage VDC 15 1 15 1 Power supply current mA lt 19 lt 15 Power connector mm 2x 1 3 2x 1 3 Temperature range C 0 50 0 50 Max current mA 500 500 Dimensions H x D x W mm 145 x 138 x 36 145 x 138 x 36 146 Triax Districom 4000 multiswitches TDA 4x5 amplifier Module for amplification of satellite signals 22 dB gain and variable attenuation Options include select able return path modules for 5 30 5 55 or 5 65 MHz TDA 122 amplifier Module for amplification of terrestrial signals 22 dB gain and variable attenuation Options include select able return path modules for 5 30 5 55 or 5 65 MHz TDA 415 TDA 425 TDA 122 Ter amplifier Technical data Districom IF amplifiers and terrestrial amplifier TDA 415 364415 TDA 425 364425 TDA 122 364122 Number of inpu
10. Multi block Duo block Duo block Flexi block 300729 300724 300722 300723 Colour Grey Black Black Black LNB angle degrees 3 20 3 6 3 10 LNB size mm O40 O40 O40 O40 Packing type Remarks O25 adaptor O25 adaptor O25 adaptor O25 adaptor optional extra optional extra optional extra optional extra Multi block brackets for the DAP series and spareparts for dishes MFD 850 DAP TD plastic TD plastic TD plastic Flexi block Spareparts Spareparts Spareparts 126309 129420 129421 129422 Colour White black Plastic Ral 7030 Plastic black Plastic Ral 7035 LNB angle degrees 3 10 LNB size mm O40 Packing type Single pcs Single pcs Single pcs Remarks O25 adaptor All plastic spare parts All plastic spare parts All plastic spare parts optional extra fits TD 54 64 78 fits TD 54 64 78 fits TD 54 64 78 and 88 dish and 88 dish and 88 dish 88 Triax LNB units the best choice Complete range of LNB units adopting the latest cutting edge RF technology Full KU band coverage for both analogue and digital reception Excellent noise figure and low phase noise High gain and excellent cross pole isolation High output and low power consumption Qualified for harsh environments Waterproof x Single packed in gift box B Technical data do eei TSI 005 TSI 003 TSI 004 Single universal Single universal Single universal 300429 300430 300432 Colour ligh
11. TYPE Single IEC Single IEC Single F Cover plate female male female Part No white insert 304250 304252 304254 304256 Part No black insert 304251 304253 304255 304257 Outputs TV radio TV radio TV radio Frequency range 5 862 5 862 5 2300 TV MHz Radio MHz SAT Il MHz Return MHz Tap loss lt 0 3 lt 0 3 lt 1 6 TV dB Radio dB SAT Il dB Return dB Connectors IEC female lIEC male F female TV Radio SAT Return DC through In SAT V mA Yes Yes Yes Fits 15 mm patress Yes Yes Yes Yes Impedance Ohm 75 75 75 Weight kg Dimensions w x h x d mm 25 x 50 25 x 50 25 x 50 25 x 50 Remarks 230 Triax GRID style outlets A flexible combine yourself range for domestic and system applications e Grid versions in polycarbonate brushed polished stainless and flat styles e White or black polycarbonate moulding Technical data on GRID style in outlets TYPE GRID GRID GRID GRID Diplexed Diplexed Triplexed Quad Part No white insert 304258 304260 304262 304264 Part No black insert 304259 304261 304263 304265 Outputs TV radio TV SAT TV radio TV radio SAT SAT Frequency range TV MHz 47 68 254 862 47 68 254 862 47 68 254 862 47 68 254 862 Radio MHz 87 5 230 87 5 230 87 5 230 SAT I SAT II MHz 950 2150 950 2150 2 x 950 2150 Return MHz Tap loss TV dB lt 1 5 lt 2 0 lt 2 0 lt 2 5 lt 2 0 lt 2 0 lt 2 5 lt 2 5 Radio dB lt 2 0 l
12. Channel Channel Channel Channel Channel Channel Channel Channel 8 8 8 8 9 9 9 9 100355 100357 100379 100382 100405 100407 100429 100432 Channel 8 8 8 8 9 9 9 9 Band BIII BIII BIII BIII BIII BIII BIII BIII Elements pcs 6 8 10 13 6 8 10 13 Gain dBi 8 5 9 5 11 0 13 5 8 5 9 5 11 0 13 5 Front to back ratio dB 19 21 24 26 19 21 24 26 Beamwidth hor deg 23 21 18 17 23 21 18 17 Windload N 48 56 84 98 48 56 84 98 Weight kg 1 2 1 7 2 8 3 2 1 1 1 6 2 1 3 1 Material Alu Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 1607 2424 2662 3675 1556 2358 2553 3675 width mm T15 790 780 810 750 7 0 760 185 Connector SC type SC type SC type SC type SC type SC type SC type SC type Type MT MT MTD MTD MT MT MTD MTD Remarks Split Split Split Split beam beam beam beam Technical data Channel Channel Channel Channel Channel Channel 10 10 10 10 11 11 100455 100457 100479 100482 100529 100532 Channel 10 10 10 10 11 11 Band Bill BIII BIII BIII BIII BIII Elements pcs 6 8 10 13 10 13 Gain dBi 8 5 9 5 11 0 13 5 11 0 13 0 Front to back ratio dB 19 21 24 26 24 26 Beamwidth hor deg 23 21 18 17 18 17 Windload N 48 56 82 88 64 80 Weight kg 1 1 1 6 2 7 3 0 2 1 3 0 Material Alu Alu Alu Alu Alu Alu Dimensions length mm 1505 2280 2543 3675 852 1410 width mm 725 740 740 765 800 800 Connector SC type SC type SC type SC type SC type SC type Type MT MT MTD MTD MTD MTD Remarks Split
13. Triax NMT and GSM aerial TRIAX Yagi aerials for NMT and GSM reception have been designed for reception of the 2 mobile phone band featuring high gain and band selectivity With their high gain and excellent front to back ratios these aerials ensure superior reception where there is a weak signal from the mobile transmitters GSM aerial 50 Ohm Technical data NMT GSM 900 GSM 900 NMT GSM 900 415 480 872 960 872 960 415 480 872 960 109808 109807 109812 109814 109815 Channel MHz 415 480 872 960 872 960 415 480 872 960 Band NMT GSM GSM NMT GSM Elements pcs 6 6 6 6 6 Gain dBi 9 0 9 0 9 0 9 0 9 0 Front to back ratio dB 15 15 15 15 15 Beamwidth hor deg 25 25 25 25 25 Windload N 14 14 14 14 14 Weight kg 0 50 0 50 0 50 0 50 0 50 Material Alu Alu Alu Alu Alu Dimensions length mm 710 710 710 710 710 width mm 260 260 260 260 260 Connector SC type SC type SC type SC type SC type Type Mast Window As 109808 As 109807 bracket bracket w cable w cable Packing size 1 1 1 1 1 29 Triax indoor aerial DVB T VHF UHF Small and very elegant passive and active indoor antenna some especially designed for reception of DVB T signals The DVB T 300 antenna comes in an elegant blister pack and the indoor FM TV aerial in a giftbox ready for display in the shop Technical data we FM indoor aerial Indoor
14. Frequency range MHz 5 1000 5 1000 5 1000 5 1000 Outputs pcs 3 3 3 3 Insertion loss in out 5 40 MHz dB lt 2 lt 2 ad lt 0 9 40 470 MHz dB lt 2 9 lt 2 9 lt 1 7 lt 0 9 470 860 MHz dB lt 3 9 lt 3 9 lt 2 2 lt 1 2 Tap loss in tap 5 40 MHz dB 10 0 1 5 12 5 41 0 16 0 1 0 20 0 1 0 40 470 MHz dB 10 0 1 5 12 0 41 5 16 0 41 5 20 0 1 5 470 860 MHz dB 10 0 1 5 12 0 41 5 16 0 41 5 20 0 1 5 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 Isolation out tap 5 40 MHz dB gt 25 0 gt 25 0 gt 32 0 gt 32 0 40 470 MHz dB gt 25 0 gt 25 0 gt 30 0 gt 30 0 470 860 MHz dB gt 22 0 gt 22 0 gt 28 0 gt 28 0 Return loss in out 5 40 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 40 470 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 470 860 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 Return loss tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No Connectors F connector F connector F connector F connector Certification CE CE CE CE Impedance Ohm 75 75 75 75 Weight kg 0 069 0 06
15. 85 Triax Unique multi reception dish Advantage of TRIAX Unique multi reception dish The Unique multi reception dish is the result of research into semi parabolic shapes and the influence on available gain in both main and side directions Through a special shaping we have stretched the focal point into a focal line and still letting each LNB uti lize all of the dish s surface thus succesfully combining efficient area utilization of side mounting with the broad and uniform azimuth beam coverage of the torus antenna Uniquely shaped dish giving high and constant gain within a 30 deg range Only one dish for reception of 2 4 satellites Simple and fast installation quick and easy to mount Simple and easy adjustment Individual setting of each LNB High mechanical strength and resistance to corrosion mechanical tests Technical data for Unique multi reception dish TD Unique TD Unique single pack 100 pcs bulk 100 x 111 cm 100 x 111 cm Part No grey Ral 7030 126390 126391 Frequency range GHz 10 7 12 75 10 7 12 75 Gain 10 70 GHz dBi 37 1 37 1 G T LNB 0 7 dB dB K X polarisation dB gt 20 gt 20 Offset angle degrees 26 0 26 0 Elevation range degrees 5 50 5 50 Reflector type F D 0 6 Offset Offset Beam width degrees 2 6 2 6 Windload 42 m s N 1230 1230 Material Steel Steel Finish Polyester powder Polyester powder coat coat LNB holder mm O40 O25
16. Technical data TMF 512 mounting frame TYPE TMF 512 1 1 19 frame 1 2 19 frame 19 basic frame with fittings with fittings Part No 251512 251513 251514 Colour Galv steel Galv steel Galv steel Height outer mm 1020 1020 510 Width outer mm 510 510 510 Depth outer mm 500 500 500 Units in mountring frame pcs 21 21 10 Remarks Wheels as option Fittings Fittings included included Accessories TYPE Set of screws Brackets for 4 Wheels 19 Shelf CM 04 unit with lock Part No 737040 737029 737030 251496 Dimension H x W x D mm 75x42x24 ZI 74 on wheels 81 x 44 45 x 270 Outer pack pcs 1 1 1 1 Remarks 10 nut bushings 4 in a set 19 shelf for satellite receiver for 10 M6x8 screws use together with e g the TCM 08 10 plastic washers or TCH modulator modules 124 Triax indoor multi distribution cabinets i Indoor wall cabinets with steel backboard e Cable entries in top and bottom e 2 EMKA locks e Steel mounting backboard with pop up brackets for taps splitters and pouyet connectors e Wooden backboard also available MDU 8 lock box Technical data MDU lock box TYPE Part No locking system lock protection 2 X single cam 2 x teardrop 2 x single cam 2 x teardrop Colour Grey Ral 7035 Grey Ral 7035 Grey Ral 7035 Height outer mm 370 490 660 Width outer m
17. Multi block brackets for the TDE series TDE 88 110 TDE 88 110 TDE 78 TDE 78 2 LNB multi block 3 LNB multi block 2 LNB multi block 3 LNB multi block 300734 300735 300736 300737 Colour Steel alu Steel alu Steel alu Steel alu LNB angle degrees 6 20 6 20 6 20 6 20 LNB size mm O40 O40 O40 O40 Weight kg Packing type Remarks O25 adaptor O25 adaptor O25 adaptor O25 adaptor optional extra optional extra optional extra optional extra TD 3 TD 6 TD 6 TD 3 10 Duo block Duo block Duo block Flexi block 300716 300715 300717 300719 Colour Black Black Grey Black LNB angle degrees 3 6 6 3 10 LNB size mm O40 O40 O40 O40 Weight kg Packing type Remarks O25 adaptor O25 adaptor O25 adaptor O25 adaptor optional extra optional extra optional extra optional extra 87 LNB brackets multi satellite reception Multi block brackets for the TD series TD 3 LNB TD LNE TD 2 LNB TD 4 LNB Multi block Multi block Multi block set Multi block set 300728 300727 300730 300725 Colour Black alu Black alu Black alu Black alu LNB angle degrees 3 20 3 20 3 20 3 20 LNB size mm O40 O40 O40 O40 Packing type Remarks O25 adaptor O25 adaptor incl 2 LNB and incl 4 LNB and optional extra optional extra MFD 21 DiSEqC switch MFD 41 DiSEqC switch Duo and flexi block brackets for the Basic series Basic 4LNB Basic 3 Basic 6 Basic 3 10
18. TRIAX Main Catalogue 2007 elmore more simply The wide variety of products pre sented in this catalogue reflects one of the benefits offered to you by Triax Easy access to any product you may need to do your job in delivering efficient direct to home and SMATV solutions Focus on customer needs has led Triax to a position of leading European supplier of products for distribution of satellite cable and terrestrial signals Our objective is to save time and trouble for installers operators and distributors in any market we serve Our market scope today includes Asia and the Middle East as well as Europe Simplicity is our keyword Advanced and complex technology is needed to give users access to the growing variety of programs and services offered today by TV broadcasters Triax offers more than the products needed We offer simplicity in system design installation and future expansion of TV systems Our products are designed to simplify the use of complex technology and our technical service is there to be used and save you time and trouble more simply Instant access to Triax workflow illustrates the all the way technical service you partnership and can expect from Triax Right from initial design customer support proposals through installation to after sales support our engineers are only a phone call away and looking forward to getting your call TRIAX Work
19. 16 N xX 3 6 m 57 6 Nm The bending moment caused by an antenna is calculated a56 N X 2 8 m 156 8 Nm by the following formula 996 N X 2 0 m 192 0 Nm 619 N X 1m 619 0 Nm Wind load N x distance m bending moment Nm Total bending moment of the antennas 1025 4 Nm The total bending moment for the antenna at 1025 4 Nm is less than the usable bending moment for the antenna to be mounted of 1250 Nm Therefore the intended configuration is permitted TEM Omni e 2 VHF ch 8 8 elem A D Damea ad ea a 4 LA 3 6 m 9 UNIX 52 TZA 2 8 m Mast 042 mm 4 Triax TDE 88 20m 0 9m Inaccordance with DIN EN 50083 1 the clamped length of the mast must EOS gd be at least 1 6 of the mast length 60 Mounting accessories Mechanical accessories 62 63 64 66 Window and wall brackets Wires and accessories Chimney brackets Cable guards and duct 67 68 69 70 11 12 13 74 Screw bolts clips and strips Mast for mounting on brackets roof beams Triax range of masts and brackets for perfect installations Triax has a wide range of mounting brackets for aerials all for your needs Please read the section with mast calculation in accordance with the EN 50083 1 norm with a restriction of 1650 Nm as maximum on a normal building 38 mm hot galvanized masts 42 mm masts for composition Technical data on hot galvani
20. 54 Triax single channel mast filters TRIAX SCF range of filters combiners are based on state of the art technology Attractive blue mast housing High out of band rejection Excellent isolation Switchable through power Mast or wall mounting Releasable maststrap CE approved SCF Single Channel Filter OTRAS FILTER TYPE J yi XX Rest VHF UHF OUT mAs SS Of OS e 118 616 CINIS TMC combiner a a SCF XX 15 filter Technical data on single channel mast filters with saddle and clamp connectors SCFXX 15 SCFXX 15 750XBI 750X BU 7508BIIl TMC69 TC 1221 A2 A4 Channel 8 SAT 317403 317405 311301 311303 311304 333383 333582 Input 1 Band UHF UHF BI BIIII BIIH SAT UHF Channel 1 ch X 1 ch X 1 ch X 1 ch X ch 8 IF 21 69 Through loss dB 3 0 3 0 1 5 2 0 2 0 3 0 1 0 Input 2 Band rest rest rest rest rest VHF UHF VHF Channel VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF 2 12 Through loss dB 1 0 1 0 1 0 2 0 0 5 0 5 2 0 1 0 Input 3 Band Channel Through loss dB Input 4 Band Channel Through loss dB Stop band attenuation Channel XX dB gt 20 gt 20 gt 15 gt 20 gt 20 VHF rest UHF dB gt 20 gt 20 gt 15 gt 20 gt 20 gt 15 gt 20 SAT dB gt 35 Numbers of in output 2 1 2 1 2 1 2 1 2 1 2 1 2 1 DC throughpower Ch XX Ch XX rest
21. 5 470 MHz dB gt 28 0 gt 28 0 470 862 MHz dB gt 25 0 gt 25 0 862 2400 MHz dB gt 20 0 gt 20 0 Approval EN 50117 CEl 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes 201 Triax QX cable for indoor use Triax QX universal coaxial cable for TV broadcast in house cabling The good attenuation shielding and return loss predestine the cable for use of both SAT IF and SMATV applications Technical data on QX double shielded indoor cable QX 4S QX 5S Double shielded Double shielded White Grey Black PVC PVC PVC White Grey Black PVC PVC PVC Part No Cardboard roll 100 m 150008 150007 Cardboard roll 200 m 150022 150021 Plastic reel 100 m 150053 150052 150054 150056 150055 Plastic reel 250 m Plastic reel 500 m Center conductor mm 0 8 1 1 Center conductor material Cu blank Cu blank Isolation mm 3 7 4 7 Dielectric PEE foamed PE foamed Screen AL PET AL AL PET um Braid material CuSn CuSn construction mm coverage 56 0 45 Screening attenuation dB Anti migration foil um Outer sheath PVC PVC Minimum bending radius mm 35 70 50 Diameter mm 5 3 6 7 Application Indoor Indoor ELECTRICAL DATA Impedance Ohm 75 75 Capacitance pF m 55 55 Velocity ratio 84 80 Center conductor dc resistance Ohm km 38 22 Outer conductor dc resistance Ohm km 40 28 Attenuation at 20
22. MFA 513 340513 MFA 507 MFA 511 340507 340511 Set consists of amplifiers MFA 307 MFA 311 MFA 313 MFA 314 power supply IFP 503 IFP 503 IFP 503 IFP 503 See specification on page amplifiers 36 37 37 37 power supply 200 200 200 200 Weight kg 0 645 0 645 0 645 0 645 Dimensions Height mm 170 170 170 170 Depth mm 78 78 78 78 Width mm 242 242 242 242 Remarks 24 V 24 V 24 V 24 V 38 Triax TA mast amplifier series TRIAX s TA 4000 amplifier The series of masthead amplifiers includes a wide range of amplifiers to substitute and supplement many of the well known types included in our product range so far e Saddle and clamp cable connection on all in and outputs e Releasable mast strap e Wide range e Low noise figures e Unique power stabilizer e RF shielded and CE marked EN 50083 e Easy wall mounting Technical data on TA mast amplifiers with saddle and clamp connectors TA 4013 TA 4013 TA 4213 TA 4312 TA 4312 322R 30R 3R 3R 2R 330487 330502 330521 330541 330542 Input 1 Band UHF UHF UHF UHF UHF Gain dB 20 30 24 34 22 32 22 32 13 23 Input 2 Band VHF VHF FM Bill Bill Gain dB 10 20 1 0 10 14 24 13 23 Input 3 Band BI BIll BI FM BI FM Gain dB 14 24 14 24 13 23 Noise figure UHF dB 2 5 1 8 2 5 2 5 3 5 VHF dB 2 5 2 5 2 5 3 5 Max output voltage 60 dB IMA GEUN 105 105 105 105 105 Numbers of in output 2 1 2 1
23. input IEC female Temperature range E 0 40 Dimensions H x D x W mm ROOM 2 ROOM 1 Triax digital EZA link sensor Receiver Triax digital link inserter 240 Technical appendix Terrestrial antennas Basic technical requirements Technical data in the catalogue Planning and installation Earthing and equipotential Frequency range of waves TV standards Channels and frequencies Colour and broadcasting Signal level mV to dBuV Frequency for radio TV channels 242 243 244 245 246 24 24 24 248 249 290 251 251 241 Terrestrial antennas Introduction Radio antennas Stereo signals can be received using any FM antenna e Average of 1 and 2 i l Because however a higher signal level and greater freedom l l l l AAN Main lobe from reflection are needed for clear stereo reception than for mono reception it is usually necessary to use a directional antenna Television antennas for DVB T DVB T reception is possible with any antenna that is suitable for the related frequency band and polarization In the catalogue all antennas suitable for the reception of DVB T signals in VHF III and UHF IV V bands are marked with the DVB logo Angle of acceptance Uy Omnidirectional reception Radiation pattern The omnidirectional radio antenna has approximately e the same sensitivity for all directions and can only be The most Important terms r
24. 1 0 16 0 1 5 40 470 MHz dB 12 0 1 0 16 0 1 0 20 0 1 0 12 0 1 0 16 0 1 5 470 750 MHz dB 12 0 1 2 16 0 1 2 20 0 1 0 12 0 1 2 16 0 1 5 750 860 MHz dB 12 0 1 5 16 0 1 5 20 0 1 2 12 0 1 5 16 0 1 5 860 1000 MHz dB 12 0 2 0 16 0 2 0 20 0 1 5 12 0 2 0 16 0 2 0 Isolation tap tap 5 40 MHz dB gt 26 0 gt 26 0 gt 26 0 gt 26 0 gt 26 0 40 470 MHz dB gt 26 0 gt 26 0 gt 26 0 gt 26 0 gt 26 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 860 MHz dB gt 24 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 860 1000 MHz dB gt 23 0 gt 23 0 gt 23 0 gt 23 0 gt 23 0 Isolation out tap 5 40 MHz dB gt 28 0 gt 30 0 gt 32 0 gt 28 0 gt 36 0 40 470 MHz dB gt 28 0 gt 30 0 gt 32 0 gt 28 0 gt 30 0 470 750 MHz dB gt 26 0 gt 28 0 gt 30 0 gt 26 0 gt 25 0 750 860 MHz dB gt 25 0 gt 26 0 gt 28 0 gt 25 0 gt 24 0 860 1000 MHz dB gt 23 0 gt 25 0 gt 27 0 gt 23 0 gt 24 0 Return loss in out 5 40 MHz dB gt 22 0 gt 20 0 gt 22 0 gt 22 0 gt 21 0 40 470 MHz dB gt 20 0 gt 20 0 gt 22 0 gt 20 0 gt 20 0 470 750 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 18 0 gt 18 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 17 0 860 1000 MHz dB gt 17 0 gt 18 0 gt 18 0 gt 17 0 gt 16 0 Return loss tap 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0
25. 258 The seller is never responsible for delays unless such delays are owing to gross negligence on his part The seller is never responsible for operational losses loss of profit loss on goods kept in stock loss caused by delayed building activities or other contract work or any other direct or indirect loss or direct or indirect costs caused by delayed deliveries If delays should occur and if at the buyer s request the seller cannot state a delivery period the buyer has the right to cancel the order and demand reimbursement of potential pre payment provided that the products have not been made especially to the customer s specifications Above statement defines the seller s maximum responsibility in relation to delays 7 PAYMENT RETENTION OF OWNERSHIP UNTIL PAYMENT IS MADE The seller reserves for himself the right of ownership until the agreed price has been paid In that case it is the buyer s duty to take out an insurance on the goods against any damage from the date of the passing of the risk until the agreed price has been paid The insurance should cover full and new value of the goods in question Until close to the date of delivery the seller has a right to demand and the customer is bound to give a banker s guarantee payable on demand in an acknowledged bank for the total purchase sum including costs and outlays As far as mounting and servicing is concerned the seller is justified to
26. 35 dB GEUN 120 General DC power for preamplifier V mA 12 50 12 or 24 60 12 or 24 60 12 or 24 60 LNB supply kHz 0 13 18 22 Power supply V AC 230 50 Hz 185 265 50 Hz 185 265 50 Hz 185 265 50 Hz Power consumption W 8 0 Connectors F con F con F con F con Impedance Ohm 75 75 75 75 Temperature operation uG 0 55 0 55 0 55 0 55 Dimensions L x H x D mm 230 x 130 x 50 354 x 215 x 50 354 x 215 x 50 354 x 215 x 50 118 ASV modules AS single channel analogue headend Triax AS series single channel amplifier for high quality reception and distribution of terrestrial TV signals High gain High selectivity 15 VDC supply voltage Fast On connector Input and output loop through single channel active filters Technical data on AS modules ASV 137 ASV 237 ASV 337 ASU 040 ASU 050 324590 324591 324592 324593 324594 Frequency band BI FM BIII Channel X Channel X E2 E4 87 5 108 MHz E5 E12 21 69 21 69 Channel band width MHz 7 7 8 8 Gain dB 37 37 37 40 50 Selectivity dB 36at 16 MHz 36at 16 MHz 36at 16 MHz 36at 16 MHz 36 at 16 MHz Attenuation dB 0 18 0 18 0 18 0 18 0 18 Output level EON 117 112 117 117 125 Output level dBuV 105 105 105 105 113 Power consumption mA 35 35 35 60 110 Connector IEC Female Female Female Female Female Temperature range C 0 50 0 50 0 50 0 50 0 50 Dimensions H x D x W mm 160 x 45 x 20 160 x 45 x 20 160 x 45 x 20 160 x 45 x 20
27. 50 Material Galv steel Galvanized Weight kg Packing QTY pcs 1 1 Remarks Bracket with Roll with 10 m 2x5msteel band steel band 70 Roof covers for pitched roof Roof cover red Technical data on roof covers Roof cover black Roof cover Roof cover Red ral 8012 Black 132202 132203 Size mm 450 x 400 450 x 400 Mast diameter mm 38 60 38 60 Material Alu with Alu with polyester polyester Weight kg Packing QTY pcs 1 1 Remarks Weatherproof Weatherproof glue leadfree glue leadfree roof cover roof cover Technical data on clips and index Clips Index R79 Index R76 Index Index ETES small big red black 133011 132211 132210 132212 132213 Diameter mm 40 60 38 50 38 50 38 60 38 60 Material Steel Rubber Rubber Rubber Rubber Weight kg Packing QTY pcs 1 1 1 1 1 Remarks delivered delivered delivered delivered with clips with clips with clips with clips 71 Cable guards en eea Cable duct 25 x 16 mm bie za N EEEko E a oS Cable d t 16x16mm Technical data on cable guards Cable guards aluminium Type Cable guards Cable guards Cable guards Cable guards Cable guards Galv steel Galv steel Galv steel Alu Alu Part No rool 0 0 010 550001 rote 0 0 0722 133053 133054 Size Width mm 16 19 23 1
28. 60 TDH Channel filter 110 325808 8100 3 BIII 32 346004 ATS 4 168 301377 Ch 6 7 TDH Channel filter 110 325804 81065 UHF amp with limiter 33 346006 ATS6 BB 301361 Ch 61 62 TDH Channel filter 110 325824 81065K amp Ch 21 46 with limiter 33 346008 ATS 8 168 301363 Ch 63 64 TDH Channel filter 110 325825 81065K amp Ch 47 68 with limiter 33 346112 ATT 1 12 169 301365 Ch 65 66 TDH Channel filter 110 315122 821 UHF 59 346116 ATT 1 16 169 301367 Ch 67 68 TDH Channel filter 110 315123 841 UHF 59 301378 Ch 8 9 TDH Channel filter 110 346120 ATT 1 20 169 A 346124 ATT 1 24 169 130000 Chimney bracket set 2 parts 70 326850 A 334350 2360 A 45 346130 ATT 1 30 169 aa enimney arac sei sel Seoc mm 5 lous Uhimney bracket set double i 2208 8 AAE ee S46106 ATT 1 6 169 130002 Chimney bracket set single 70 oo ea o SEE 169 130006 Get bracket set TE m mast 70 326861 A 5053 7 A1 45 346210 ATT 2 10 170 130107 Clam 68 326905 A XX A1 ch 5 6 BIII 48 346212 ATT 2 12 170 133100 GEO wath boll 68 Ee a8 346216 AUZ d Der Cips gall pack with 1000 pcs 74 326909 A XX A1 ch 9 11 DII 48 346220 ATT 2 20 170 Ee Sa de A p pes b eee SE egia IZ pi Ge rz pack with 1000 pes 74 326980 AXXYY A2 multichannel 48 346208 ATT 2 8 170 p pes Weed a SS Kd FC ppp o 300109 CM 01 Combi FM UHF AU NZ 117 326840 A XXYY 00 A1 45 346310 ATT 3 10 171 300104 CM 01 Combi FM UHF PAL G 117 S262 ANZ Al Sea HZ 300107 CM 01 Combi VHF AU NZ 117 326976 _A881
29. AU NZ BG Video audio cable for Nicam Output frequency range MHz 175 342 470 862 ezteko Picture carrier stability kHz lt 70 lt 70 3 phono connector 100 cm Part No 300738 Spurious ref picture carrier dB gt 60 gt 60 Output level max dBuV 95 2 5 95 2 5 Output impedance Ohm 75 75 Return loss dB gt 10 gt 10 Differentiel gain lt 8 lt 8 Differentiel phase Deg lt 8 lt 8 Crominance luminance delay nS lt 80 lt 80 Video audio cable k Modulator cable with scart and Luminance non linearity lt 8 lt 8 3 phone connectors 150 cm Video S N ratio dB gt 55 gt 52 PA Sound sub carrier MHz 5197 6 07 6 5 5 5 6 0 6 5 Sound sub carrier stability kHz lt 5 lt 5 Audio distortion 1 KHz lt 1 lt 1 Audio S N ratio dB gt 55 gt 55 Video Input level Vpp 0 8 1 3 0 8 1 3 i Spare RF connection cable Input impedance Ohm 19 19 Length 20cm Part No 452090 Audio _ Input level Vrms 0 5 1 0 0 5 1 0 0 2 pen EO ede Input impedance kOhm 10 10 gt 10 Power supply Voltage DC mA 12 117 12 110 12 135 Power consumption W 1 4 1 5 Connectors RF output OUT 1xF 1xF Audio Video input 3 x RCA 3 x RCA 4 x RCA Power supply via RF utg ng via RF utg ng 1xF Other types of connection Weight kg 0 1 0 1 0 1 111 in this catalogue Dimensions L x B x H mm 96 x 25 x 67 96 x 25 x 67 96 x 25 x 67 116 Triax stand alone modulator CM 01 single channel stand alone
30. CLASS GRADE 1 ATS 2 ATS 3 ATS 4 ATS 6 ATS 8 346002 346003 346004 346006 346008 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 2 3 4 6 8 3 Out 1 Out 2 3 Insertion loss in out 5 40 MHz dB lt 3 6 lt 5 4 lt 7 2 lt 9 4 lt 10 2 lt 3 3 lt 6 8 40 470 MHz dB lt 3 8 lt 5 8 lt 7 4 lt 9 8 lt 10 2 lt 3 5 lt 7 0 470 750 MHz dB lt 3 9 lt 6 2 lt 7 6 lt 10 2 lt 10 7 lt 3 6 lt 7 2 750 860 MHz dB lt 4 0 lt 6 5 lt 7 8 lt 10 5 lt 10 7 lt 3 9 lt 7 6 860 1000 MHz dB lt 4 2 lt 6 8 lt 8 2 lt 10 8 lt 11 0 lt 3 9 lt 7 6 Isolation 5 40 MHz dB gt 28 0 gt 23 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 26 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 750 MHz dB gt 26 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 860 MHz dB gt 25 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 gt 25 0 gt 25 0 860 1000 MHz dB gt 25 0 gt 24 0 gt 24 0 gt 22 0 gt 22 0 gt 24 0 gt 24 0 Return loss in 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 470 750 MHz dB gt 19 0 gt 22 0 gt 19 0 gt 18 0 gt 18 0 gt 20 0 gt 20 0 750 860 MHz dB gt 19 0 gt 19 0 gt 19 0 gt 17 0 gt 17 0 gt 20 0 gt
31. EN 50083 10 System performance for return paths The system and equipment requirements are matched to each other in such a way that the minimum requirements for signal quality at the subscriber s outlet can be met with a minimum of technical effort In addition requirements that result from use of both analogue and digital signal transmission have also been taken into account The EN 50083 standards provide the network operator planner and installer with concrete guidelines for network design and selection of appropriate network components Hirschmann network components are developed to these standards and are marked in the catalogue by the relevant EN standard The equipment standards EN 50083 Parts 3 6 include fulfillment of the safety and EMC requirements EN 50083 Parts 1 2 The legally required CE marking for antenna and telecommunication products refers to adherence to electromagnetic compatibility EMC limits and from 1 Jan 1997 to adherence to the low voltage directive The CE marking does thus not imply fulfilment of the product and system requirements according to EN 50083 3 10 For this reason Triax indicates compliance with these basic requirements on equipment EN 50083 3 6 by explicitly noting the corresponding EN standard in the catalogue and in the operating instructions 1 1 Marking of components for TV cable networks With the CE marking Triax confirms the compliance of its products with the applic
32. Types and Part No of Yagi 18 single pack channelized aerials appear from the below table Yagi 18 types Part No Ch 21 23 w support boom 108269 Ch 24 26 w support boom 108268 Ch 27 30 w support boom 108265 Ch 31 34 w support boom 108266 Ch 35 38 w support boom 108257 Ch 39 43 w support boom 108264 Ch 44 49 w support boom 108262 Ch 50 55 w support boom 108267 Ch 56 62 w support boom 108263 Ch 63 69 w support boom 108259 Technical data Yagi 18 Yagi 18 Triax Yagi band IV V aerial UHF All of the YAGI aerials are provided with the newly developed snap lock dipole house made from blue UV resistant plastic which protects the new and improved balun with capacitive signal transfer against corrosion The aerials are provided with adjustable elevation mast brackets designed for masts up to 60 mm Yagi 18 w support beam Yagi 18 Yagi18 Yagi 18 Ch 21 23 Ch 21 23 Ch 35 38 Ch 50 55 107269 107368 108269 108257 108267 Channel 21 23 21 69 21 23 35 38 50 55 Band BIV V BIV V BIV V BIV V BIV V Elements pcs 18 18 18 18 18 Gain dBi 15 5 14 5 15 6 15 5 15 5 Front to back ratio dB 25 25 25 25 25 Beamwidth hor deg 17 18 17 17 17 Windload N 64 59 64 64 64 Weight kg 0 95 1 05 0 95 0 95 0 95 Material Alu Alu Alu Alu Alu Dimensions length mm 1800 1446 1800 1800 1800 width mm 350 420 350 350 350 Connector F con F con SC type SC typ
33. terminator terminator terminator terminator Part No 10 pcs 153054 364025 Part No 5 pcs 342503 342504 Remarks Remarks TD outlets TOU outlets amp K NA amp 211 Triax ground isolators and coublings Ground isolator TYPE Ground Ground Isolator SAT Isolator RF Part No 1 pcs 153571 153572 Insertion loss 5 470 MHz dB 1 0 1 0 Insertion loss 470 1000 MHz dB 1 5 1 5 Insertion loss 1000 1750 MHz dB 2 9 Insertion loss 1750 2400 MHz dB 3 5 IEC coax gather TYPE Coax coupling Coax coupling Grey White TZA or Part No 1 pcs 153051 153055 Cable Con cable assembly kit CC SP 01 CC SP02 CC SP04 cable cable cable assembly kit assembly kit assembly kit Part No 1 pcs 153540 153542 153544 Cable diameter mm 7 10 15 Remarks Complete set Complete set Complete set with coupling with coupling with coupling and crimp flex and crimp flex and crimp flex ey Cable assembly kit Triatan 18 05 Triatan 18 10 cable cable assembly kit assembly kit Part No 1 pcs 590205 153542 Cable diameter mm 7 10 Remarks Complete kit Complete kit for coupling with for coupling with mould and form mould and form 212 Power cable and electricity articles Loudspeaker and power cable 2x0 5U grey 2x0 5 white 2x0 75 grey 2x 0 75 white loudspeaker loudspeaker PKLF PKLF cable power cable power cable Part No Plast drum 100 m 152015
34. 1 0 passive 1 0 active 17 0 active 17 0 active 17 0 Linearity dB 1 0 1 0 1 0 Return loss input 1 5 dB octave dB gt 14 5 MHz gt 14 5 MHz gt 14 5 MHz to 65 MHz to 65 MHz to 65 MHz Return loss output 1 5 dB octave dB gt 14 5 MHz gt 14 5 MHz gt 14 5 MHz to 65 MHz to 65 MHz to 65 MHz General Power supply type Mains powered Mains powered Mains powered Power supply V AC 230 10 230 10 230 10 Power consumption W 7 9 7 9 7 9 Shielding efficiency VHF dB 100 100 100 Shielding efficiency UHF dB 90 90 90 Housing protection class IP65 IP65 IP65 Connectors F connectors F connectors F connectors Certification CE CE CE Impedance Ohm 75 75 75 Operation temperature range C 0 55 0 55 0 55 Weight kg 1 325 1 325 1 325 Dimensions h x d x w mm 145 x 70x 170 145 x 70x 170 145 x 70x 170 1 DIN EN 50083 Part 3 CTBA Composite triple beat ratio 60 dB IMD CENELEC raster 42 channels 157 Triax Accessories for HFA amplifiers 5MHz 30 47 55 65 73 87 862 MHz No diplexfitr Forward MD 3047 T Return path Z Forward MD5573 T Returnpath E Forward y O MD6587 T Retumpah DAZZA Fowad O MD diplex filter modules amp E e MD diplex modules TYPE MD 3047 ND 3047T MD 5573 MD 5573T ND 60587 MD 6587T Part No 324681 324682 324685 324686 324683 324684 Frequency range return path MHz 5 30 5 30 5 55 5 55 5 65 5 65 Frequency range forward path MHz 47 862 47
35. 104622 Aerial 3el ch 7 8 13 140030 38mm x 1 5 m Mast 62 153013 Cable clips Natural 2x4mm pack with 100 pcs 73 104642 Aerial 3el ch 9 11 13 140111 38mm x 2 m Mast 62 104603 Aerial 4el ch 5 6 13 153001 Cable clips Natural 3x5mm pack with 100 pcs 73 140031 38mmx3m Mast 62 104623 Aerial Jel sh 78 13 153003 Cable clips Natural 5 20 pack with 100 pcs 73 140113 38mmx3m Mast 62 EEA 153080 Cable clpis black FC 7 9 pack with 100 pcs 73 104643 Aerial 4el ch 9 11 13 140112 38mm x 4 m Mast 62 100604 Aerial 5el ch 5 6 13 153090 Cable duct 16x16 white 72 140110 38 mm x 6 m Mast 62 100624 Aerial EG GE 7 8 13 153092 Cable duct 25x16 white 72 338130 407 4 Splitter 195 E Oda 153057 Cable grommet black 74 a 100644 Aerial 5el ch 9 11 13 338131 407 DC1 4 splitter 195 760056 Cable grommet grey 74 Se 100305 Aerial Gel ch 7 14 140025 42 mm x 2 m Mast for composition 62 550000 Cable guards 16 mm f2 100255 Aerial Gel ch 6 14 140115 42 mm x3 m Mast 62 400405 Aerial Gel ch 9 45 550001 Cable guards 19 mm 72 140114 42mm x 6 m Mast 62 100355 Aerial Gel ch l 8 15 550002 Cable guards 23 mm 72 140028 50mm x 2 m Mast for composition 62 100455 Aenal Gel ch 10 15 133053 Cable guards 10 12 mm 72 140029 50mmx3m Mast for composition 62 So eG 133054 Cable guards 10 12 mm 72 100205 Aerial 6el ch 5 14 140126 50 mm x 3 m Mast 62 100307 Aerial 8el ch 7 14 150110 Cable Stand 207 140121 50 mm x 3 m Mast 63 EEE 153601 Cable stri
36. 15 cm 150 cm in out 150 cm 150 cm 200 cm 300748 300745 300749 300743 300746 Lenght cm 15 150 150 150 200 Packing QTY pcs 1 1 1 1 1 Remarks 15 cm cable 150 cm cable 150 cm cable fitted IGO cm cable 200 cm cable fitted with fitted with with 15 pol D sub fitted with 3 x fitted with 3 x 15 pol D sub and 15 pol D sub and and 3 x phone phone male and phone male and 3 x phone male 3 x phone male mele 3 x phone Scart connector Scart connector connector connector female connector Decoder cable TCM 08 Nicam USB RS 232 cable RS 232 cable Technical data on TDH connection cable Decoder cable Video audio USB RS 232 RS 232 cable 150 cm for Nicam cable 180 cm 300742 300738 300769 300769 Lenght cm 150 100 40 180 Packing QTY pcs 1 1 1 1 Remarks 150 cm cable fitted Modulatorcable 40 cm cable 180 cm cable with 15 pol D sub with scart and 3 between TDH PC between TDH PC to Scart connector phono connector or or for TCM08 TDH N port box TDH N port box 111 TCH 600 headend for analogue TV FM Triax TCH 600 compact headend TCH 600 is an analogue compact headend with a high level of flexibility The basic unit holds up to 8 analogue modulators each carrying one VHF i UHF or FM channel Several basic units can be cascaded in order to reach ma the number of channels required E a E e Flexible configuration can be changed according to changing needs v e Quick
37. 20 0 860 1000 MHz dB gt 19 0 gt 19 0 gt 18 0 gt 17 0 gt 17 0 gt 18 0 gt 18 0 Return loss out 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0 gt 20 0 gt 20 0 gt 22 0 gt 22 0 40 470 MHz dB gt 22 0 gt 20 0 gt 20 0 gt 18 0 gt 18 0 gt 22 0 gt 22 0 470 750 MHz dB gt 20 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 20 0 gt 20 0 750 860 MHz dB gt 20 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 20 0 gt 20 0 860 1000 MHz dB gt 19 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No Connectors F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE CE Impedance Ohm 75 75 75 75 15 75 Weight kg 0 070 0 085 0 106 0 138 0 135 0 085 Dimensions h x d x w mm 38x 16x 74 38 x 16 x 96 38 x 16 x 118 38 x 16 x 161 36 x 28x 115 38 x 16 x 96 168 CLASS GRADE 1 Triax taps ATT series 5 1000 MHz ATT 1 6 ATT 1 8 ATT 1 12 ATT 1 16 ATT 1 20 ATT 1 24 ATT 1 30 346106 346108 346112 346116 346120 346124 346130 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 1 1 1 1 1 1 1 Insertion loss in out 5 40 MHz dB lt 2 4 lt 2 1 lt 0 9 lt 0 8 lt 0 7 lt 0 7 lt 0 7 40 470 MHz dB lt 2 17 lt 2 2 lt 1 1 lt 0 9 lt 0 8 l
38. 26 0 gt 26 0 860 1000 MHz dB gt 20 0 gt 24 0 gt 25 0 gt 25 0 gt 26 0 gt 26 0 Return loss in out 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 470 750 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 17 0 gt 17 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Return loss tap 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 470 750 MHz dB gt 17 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 750 860 MHz dB gt 17 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 17 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No Connectors F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg 0 085 0 085 0 085 0 085 0 085 0 085 Dimensions h x d x w mm 38x16x96 38x16x96 38x16x96 38x16x96 38x16x96 38x16x96 170 CLASS GRADE 1 Triax taps ATT series 5 1000 MHz ATT 3 10 ATT 3 12 ATT 3 16 ATT 3 20 346310 346312 3463
39. 35 0 40 470 MHz dB gt 32 0 gt 30 0 gt 30 0 gt 35 0 gt 35 0 470 750 MHz dB gt 32 0 gt 30 0 gt 30 0 gt 35 0 gt 35 0 750 862 MHz dB gt 32 0 gt 30 0 gt 30 0 gt 35 0 gt 35 0 Isolation tap tap 5 40 MHz dB gt 29 0 gt 29 0 gt 29 0 gt 30 0 gt 30 0 40 470 MHz dB gt 29 0 gt 29 0 gt 29 0 gt 30 0 gt 30 0 470 750 MHz dB gt 29 0 gt 29 0 gt 29 0 gt 30 0 gt 30 0 750 862 MHz dB gt 29 0 gt 29 0 gt 29 0 gt 30 0 gt 30 0 Return loss out 5 40 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 40 470 MHz dB gt 20 0 gt 20 0 gt 22 0 gt 22 0 gt 22 0 470 750 MHz dB gt 20 0 gt 20 0 gt 22 0 gt 22 0 gt 22 0 750 862 MHz dB gt 20 0 gt 20 0 gt 22 0 gt 22 0 gt 22 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10A dB gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In Out In Out In Out In Out In Out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector Certification CE CE Ce CE CE Impedance Ohm 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 193 Triax splitters TFS Indoor splitters with F connectors in a shielded housing with white plastic cover and only for indoor use TFS 220 and TFS 221 are splitters in a plas
40. 5 12 12 252 Contents from A to Z 150120 Coax KOKA6 201 317237 E 334350 00 A3 54 H 150121 KOKA 50 Coax KOKA 6 201 317233 F 334350 2360 A1 54 322039 HDA 3038 LAI Line powered 152 150122 Coax KOKA 6 201 317240 F XXYY 00 A1 53 322045 HDA 3038 LAZ Line powered 152 150131 Coax KOKA 6 201 317241 F XXYY 00 A2 53 322027 HDA 3038 LP1 Li d 152 150144 Coax KOKA 6 CCS 201 317242 F XXYY 00 A3 53 ae one pow o 150149 Coax KOKA 6 CCS black 204 153596 E Con Male Male bag with 5 pcs 211 Eine powered 322042 HDA 3038 MA1 Mains powered 152 150160 Coax KOKA 80 200 708020 Fan 230V 123 322048 HDA 3038 MA2 Mains powered 152 150161 Coax KOKA 80 200 153592 F angle connector bag with 5 pcs 211 322030 HDA 3038 MP1 Mains powered 152 150162 Coax KOKA 80 200 153220 F Compression CX3 4 9 210 322036 HDA 3038 MP2 Mai d 152 150173 Coax
41. Connector SC type SC type SC type SC type Remarks 20 19 18 17 FEE E 15 14 BB Grid 4 stacking 1 l Gain dB oOo a KM GA b GS dS d Ga UR A A KN B I e 4 stack m 2 stack amp single BB Grid Ch 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 Gain for single and stacked BB Grid aerial 23 Triax Log periodic aerial VHF UHF UHF A log periodic aerial is especially suitable for poor reception conditions with reflection shadows but where the signal level is OK Log periodic VHF UHF Log periodic UHF 108680 Log periodic UHF 108678 Technical data Log periodic Log periodic Log periodic VHF UHF UHF UHF 108679 108678 108680 Channel 5 12 21 69 21 69 21 69 Band BIII BIV V BIV V BIV V Elements pcs 32 28 30 Gain dBi 8 0 9 0 8 0 10 0 Front to back ratio dB gt 25 gt 22 gt 30 Beamwidth hor deg 25 28 25 ver deg 20 Windload N 39 25 30 Weight kg 0 70 0 54 0 60 Material Alu Alu Alu Dimensions length mm 1230 770 1210 width mm 850 320 320 Connector SC type F con F con Remarks Log 32 elem ch 5 12 Ch 21 69 Log 30 elem Ch 21 69 Gain 12 Gain 12 10 8 6 4 2 Ch 02 04 05 12 Ch 21 31 41 51 61 69 Ch 21 31 41 51 61 69 Log periodic
42. Depth mm 62 62 62 62 62 62 Width mm 118 118 118 118 118 118 Remarks Wideband Groupband Groupband Groupband Groupband Multiband 40 Triax TA mast amplifier series TRIAX s TA masthead amplifier Masthead amplifiers with saddle and clamp connections Weatherproff housing Fully screened enclosure Unique mounting system Flexible 12 24 volt powering High output capability with low noise TA 25 amplifier Technical data on TA mast amplifiers with saddle and clamp connectors TA 25W TA 25A TA 25B TA 25C D TA 25W 1W band A band B band C D 333401 333431 333434 333437 333501 Input 1 Channel Band 21 69 21 37 35 53 48 69 21 69 Gain dB 25 25 25 25 25 Noise figure dB lt 1 8 lt 1 8 lt 1 8 lt 1 8 lt 1 8 Input 2 Channel Band BI BII BIII Gain dB 1 0 Noise figure dB Max output voltage 60 dB IMA dBuyuV 105 105 105 105 105 Numbers of in output 1 1 1 1 1 1 1 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 Power mA 30 30 30 30 30 DC throughpower No No No No Switchable Connector S amp C S amp C S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 0 175 0 175 Dimensions Height mm 19 79 79 79 79 Depth mm 62 62 62 62 62 Width mm 118 118 118 118 118 Remarks Wideband Groupband Groupband Groupband Multiband 41 Triax TA mast amplifier series TRIAX s TA mast amplifier Weatherproof housing Fully screened enclosure Unique mounting system Flexible
43. F f port Provides uninterrupted power and RF service when the faceplate is removed Technical data TLT series of 5 1000 MHz outdoor 2 taps TLT 204 TLT 208 TLT 211 TLT 214 TLT 217 TLT 220 80261 80243 80228 80234 80229 80230 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 1 Outputs pcs 2 2 2 2 2 2 Insertion loss 5 40 MHz dB lt 3 2 lt 2 4 lt 1 4 lt 1 2 lt 0 8 40 470 MHz dB lt 4 0 lt 2 5 lt 1 8 lt 1 6 lt 1 3 470 750 MHz dB lt 5 0 lt 3 5 lt 2 3 lt 2 1 lt 1 8 750 862 MHz dB lt 5 0 lt 4 0 lt 3 0 lt 2 4 lt 2 2 Tap loss output 5 40 MHz dB 4 0 1 0 8 0 1 0 11 0 1 0 14 0 1 0 17 0 1 0 20 0 1 0 40 470 MHz dB 4 0 1 0 8 0 1 2 11 0 1 0 14 0 1 0 17 0 1 0 20 0 1 0 470 750 MHz dB 4 0 1 0 8 0 1 5 11 0 1 5 14 0 1 5 17 0 1 5 20 0 1 5 750 862 MHz dB 4 0 1 0 8 0 1 5 11 0 1 5 14 0 1 5 17 0 1 5 20 0 1 5 Isolation out tap 5 40 MHz dB gt 16 0 gt 15 0 gt 20 0 gt 25 0 gt 26 0 gt 26 0 40 470 MHz dB gt 24 0 gt 22 0 gt 24 0 gt 24 0 gt 28 0 gt 28 0 470 750 MHz dB gt 24 0 gt 20 0 gt 20 0 gt 25 0 gt 25 0 gt 25 0 750 862 MHz dB gt 23 0 gt 18 0 gt 18 0 gt 25 0 gt 23 0 gt 23 0 Isolation tap tap 5 40 MHz dB gt 16 0 gt 20 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 24 0 gt 25
44. Mitra Cross section Condition Example Copper 4 mm 2 3mm bare or insulated Koka Frequency ranges of radio waves Frequency Int abb Abb Modulation Channel Channels Frequency Wave range Picture width length sound Long wave LF L AM 9 kHz 2 4 150 285 kHz 2000 1050 m V Medium wave MF M AM 9 kHz 510 1605 kHz 590 187 m V Short wave HF K AM 9 kHz 3 95 26 1 MHz 76 11 5 m V Band VHF F AM FM 7 MHz 2 4 47 68 MHz 6 35 4 4 m H V Band II radio VHF UKW FM 300 kHz 2 70 87 5 108 MHz 3 4 2 8 m H S channels VHF USB AM FM 7 MHz s2 s10 111 174 MHz 2 1 m 1 Band Ill VHF F Ill AM FM 7 MHz 5 12 174 230 MHz 1 77 1 3m H V S channels VHF OSB AM FM 7 MHz s11 s20 230 300 MHz 1 3 1 0m 1 S channels UHF ESB AM FM 8 MHz s21 s38 302 446 MHz 99 68 cm 1 Band IV UHF FIV AM FM 8 MHz 21 39 470 622 MHz 64 68 cm H V Band V UHF FV AM FM 8 MHz 40 60 622 790 MHz 48 38cm H V _1 in wideband installation 5 TV standards Standard No of lines Channel width Video band Video audio Vestigial side Video Audio MH2 width seperation band modulation modulation MHz MHz MHz B CCIR 625 7 5 5 5 5 742 0 75 negative FM FM D OIRT 625 8 6 6 5 0 75 negative FM G CCIR 625 8 5 5 5 45 742 0 75 negative FM FM H B 625 8 5 5 5 1 25 negative FM GB 625 8 5 9 6 0 1 25 negative FM K OIRT 625 8 6 6 5 0 75 negative FM K1 CCIR 625 8 6 6 5
45. TV MHz 47 68 125 862 47 68 174 862 47 68 125 862 47 68 125 450 47 68 125 450 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 87 5 108 DAB MHz 111 125 111 125 111 125 111 125 111 125 SAT MHz 950 2150 950 2150 950 2150 950 2150 950 2150 Tap loss Return dB 3 0 13 0 TV dB 3 0 0 8 0 5 10 0 10 0 2 5 1 8 3 0 2 0 1 5 Radio dB 8 0 1 5 10 0 1 8 1 5 DAB dB 3 0 0 5 10 0 1 8 1 5 SAT dB 4 0 0 5 11 0 3 0 2 0 Connectors TV lIEC male IEC male lIEC male IEC male IEC male Radio lIEC female IEC female lIEC female IEC female lIEC female SAT F female F female F female F female F female DC through Standards CE Impedance Ohm 75 75 75 75 75 Weight kg Dimensions mechanical mm O60 60 O60 60 O60 Remarks Please refer to page 234 for cover frame and terminators 228 Triax GAD series of tv radio outlets GAD outlet housing Technical data on GAD outlets TYPE GAD 252 GAD 253 GAD 254 GAD 255 Part No loop through loop through loop through loop through excl cover and frame 1 pcs 023252 023253 023254 023255 Outputs TV radio DAB TV radio DAB TV radio DAB TV radio DAB Return SAT Return SAT Return SAT Return SAT Frequency range Return MHz 4 30 4 30 4 30 4 30 TV MHz 47 68 125 862 47 68 125 862 47 68 125 862 47 68 125 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 DAB MHz 111 125 111 125 111 125 111 125 SAT MHz 950 2150 950 2150 950 2150 950 2150 Through loss Return dB 5 0 2 0 1 5 1 0 TV dB 4
46. Tap 5 6 5 40 MHz dB 14 5 41 2 14 5 1 2 40 470 MHz dB 14 5 41 2 14 5 1 2 470 750 MHz dB 14 5 41 5 14 5 1 5 750 860 MHz dB 14 5 42 0 14 5 2 0 860 1000 MHz dB 14 5 42 5 14 5 2 0 Tap loss In Tap 7 8 5 40 MHz dB 15 5 1 5 40 470 MHz dB 15 5 1 5 470 750 MHz dB 15 5 2 0 750 860 MHz dB 15 5 2 5 860 1000 MHz dB 15 5 2 5 Isolation Tap Tap 5 40 MHz dB gt 32 0 gt 32 0 gt 32 0 40 470 MHz dB gt 30 0 gt 30 0 gt 30 0 470 750 MHz dB gt 28 0 gt 28 0 gt 28 0 750 860 MHz dB gt 28 0 gt 28 0 gt 28 0 860 1000 MHz dB gt 28 0 gt 28 0 gt 28 0 Return loss In Tap 5 40 MHz dB gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 20 0 gt 20 0 gt 20 0 470 750 MHz dB gt 18 0 gt 18 0 gt 18 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB 110 0 110 0 110 0 Power pass No No No Connectors F connector F connector F connector Certification CE CE CE Impedance Ohm 75 fo 75 Weight kg 0 138 0 138 0 135 Dimensions h x d x w mm 38x16x 161 38x16x 161 36x 28x 115 173 Triax splitter HTS series 5 1000 MHz TYPE HTS 2 HTS 3 HTS 4 HTS 6 HTS 8 HTS 12 HTS 16 Part No 347002 347003 347004 347006 347008 347912 347916 Part No with DC pass 347012 347013 347014 347016 347018 Frequency range MHz 5 1000 5 1000 5 10
47. Through loss TV dB Radio dB Data dB Tap loss TV dB 4 5 2 5 2 0 Radio dB 4 5 2 5 2 0 Data dB 4 0 8 0 10 0 Isolation Data Radio 5 65 65 862 dB gt 50 2 25 gt 50 2 25 gt 50 25 Data TV 5 65 65 862 dB gt 60 gt 22 gt 60 gt 22 gt 60 gt 22 Data out dB Radio TV dB gt 20 gt 20 gt 20 TV out dB Radio out dB Return loss TV EN 50083 4 dB Cat C Cat C Cat C Radio EN 50083 4 dB Cat D Cat D Cat D Data EN 50083 4 dB Cat B Cat B Cat B Shielding factor VHF dB gt 85 gt 85 gt 85 UHF dB gt 75 gt 75 gt 15 Connectors TV IEC male IEC male IEC male Radio lIEC female lIEC female IEC female Data F female F female F female DC through No No No Standards CE EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 Weight kg 0 165 0 165 0 165 Dimensions mechanical mm 60 O60 O60 Remarks Please refer to page 232 for cover frame and terminators According to CENELEC B 5 40 MHz gt 18 dB 40 862 MHz min 18 dB 1 5 oct C 5 40 MHz gt 14 dB 40 862 MHz min 14 dB 1 5 oct D 5 862 MHz gt 10 dB 219 Triax TOU satellite tv amp radio outlets Triax TOU loop through satellite tv radio high quality outlets The Triax TOU series of outlets is made of diecast aluminium the coax IEC connectors fulfil the DIN 45325 and IEC 169 standards The outlets can be built into a 60 mm round wall box or surface mounted by means of a TOU frame Technical data on SAT outlets 5
48. e Full band high quality modulator e Mono sound A2 stereo Nicam available TDH slave module Technical data TDH Slave modules VSB VHF UHF TDH slave TDH slave DVB S T DVB S T Mono A2 stereo Nicam Part No B G 490744 490745 590745 D K 490704 490705 Norm L 490704 Pal 490704 Modulator type VSB VSB Output frequency range Ch 2 69 2 69 MHz 47 862 47 862 Output level attenuator dB 10 10 Video S N ratio dB gt 54 gt 54 Differential phase deg lt 8 lt 8 Picture carrier stability kHz lt diz 70 lt 70 Spurious signals ref pict carrier C N dB gt 60 gt 60 Sound mode Mono A2 stereo Nicam Audio distortion 1 kHz lt 1 lt 1 Audio S N ratio dB gt 50 gt 50 Sound sub carrier stability kHz lt biz D lt die D Teletext type Reinserted in VBI Reinserted in VBI Demultiplexer data rate Mbps lt 65 lt 65 Video data rate Mbps lt 15 lt 15 Viterbi rates Mpps 1 380 SCPC MCPC 1 30 GCPC MCPC Impedance Ohm 75 75 Operation temperature range C 10 50 10 50 Weight standard module kg 0 30 0 30 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 Remarks 103 TDH digital QAM QPSK to QAM TDH QPSK to QAM module receives a QPSK channel TV program package located in the sat IF band and remodulates it in QAM format on a 5 9 MHz channel located within the RF frequency band Outp
49. gt 25 0 gt 25 0 gt 25 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No Connectors F connector F connector F connector F connector Certification CE CE CE CE Impedance Ohm 75 75 75 75 Weight kg 0 092 0 092 0 092 0 092 Dimensions h x d x w mm 60x16x70 60x16x70 60x16x70 60x16x70 178 Triax taps HTT series 5 1000 MHz E KLASSE CLASS HTT 6 16 HITT 6 20 HIT 6 24 HTT 8 16 HTT 8 20 HITT 8 24 347616 347620 347624 347816 347820 347824 Frequency range MHz 5 862 5 862 5 862 5 1000 5 1000 5 1000 Outputs pcs 6 6 6 8 8 8 Insertion loss in out 5 40 MHz dB lt 2 0 lt 1 2 lt 1 2 lt 2 5 lt 1 2 lt 1 2 40 470 MHz dB 22 5 lt 1 2 lt 1 2 lt 2 5 lt 1 2 lt 1 2 470 860 MHz dB lt 2 9 lt 2 2 lt 2 2 lt 2 9 lt 1 9 lt 1 9 Tap loss lin tap 5 40 MHz dB 16 0 1 0 20 0 1 0 24 0 1 0 16 0 1 5 20 0 41 0 24 0 1 0 40 470 MHz dB 16 0 1 5 20 0 1 5 24 0 1 5 16 0 1 5 20 0 41 0 24 0 1 0 470 860 MHz dB 16 0 1 5 20 0 1 5 24 0 1 5 16 0 2 0 20 0 1 8 24 0 1 8 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 Isolation Oout tap 5 40 MHz dB g
50. gt 30 0 1000 1750 MHz dB gt 20 0 gt 22 0 gt 22 0 gt 25 0 gt 25 0 gt 25 0 1750 2150 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 22 0 gt 25 0 gt 25 0 2150 2400 MHz dB gt 18 0 gt 18 0 gt 20 0 gt 22 0 gt 25 0 gt 25 0 Return loss in out 5 40 MHz dB gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 40 1000 MHz dB gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 1000 1750 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 1750 2150 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 2150 2400 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 Return loss tap 5 40 MHz dB gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 40 1000 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 16 0 1000 1750 MHz dB gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 1750 2150 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 2150 2400 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass In Out In Out In Out In Out In Out In Out Connectors F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg 0 046 0 046 0 046 0 046 0 046 0 046 Dimensions h x d x w mm 50x16x52 50x16x52 50x16x52 50x16x52 50x16x5
51. mono MHz 27 32 114 331437 SCF 37 15A3 comb K37 57 140034 Steel band 70 302450 TD 200 224 331438 SCF 38 15A3 comb K38 57 133007 Steel wire galvanized 3 69 303450 TD 200 224 331439 SCF 39 15A3 comb K39 57 133105 Steel wire galvanized 5 69 302455 ID GOIE 224 331440 SCF 40 15A3 comb K40 57 133020 Steel wire galvanized 5 69 303455 TD201R 224 331441 SCF 41 15A3 comb KAI 57 133002 Steel wire galvanized 5 69 302456 TD 201T 224 331442 SCF 42 15A3 comb K42 57 133005 Steel wire PVC covered 1 2 2 3 69 303456 TD 201T 224 331443 SCF 43 15A3 comb K43 57 348002 STS2 181 302412 TD212B 221 331444 SCF 44 15A3 comb K44 57 348003 STS3 181 303412 1TD212B 221 331445 SCF 45 15A3 comb K45 57 348004 STS4 181 302415 TD 250 SAT 222 331446 SCF 46 15A3 comb K46 57 348006 STS6 181 303415 TD 250 SAT 222 331447 SCF 47 15A3 comb K47 57 348008 STS8 181 302465 TD 250 SAT 222 331448 SCF 48 15A3 comb K48 57 348110 STT 1 10 182 303465 TD 250 SAT 222 331449 SCF 49 15A3 comb K49 57 348112 STT 1 12 182 302416 TD 252 SAT 222 331450 SCF 50 15A3 comb K50 57 348116 STT 1 16 182 303416 TD 252 SAT 222 331451 SCF 51 15A3 comb K51 57 348120 STT 1 20 182 302466 TD 252 SAT 222 331452 SCF 52 15A3 comb K52 57 348124 STT 1 24 182 303466 TD 252 SAT 222 331453 SCF 53 15A3 comb K53 57 348108 STT 1 8 182 302510 TD260D 221 331454 SCF 54 15A3 comb KOA 57 348210 STT 2 10 183 303510 TD 260D 221 331455 SCF 55 15A3 comb K55 57 348212 STT 2 12 183 302460 TD 260D 22
52. 0 1 5 6 0 1 5 8 0 1 5 Terminal Terminal 470 860 MHz dB 4 0 1 5 6 0 1 5 8 0 1 5 Tap loss in tap 1 5 1 5 1 5 1 5 1 5 5 860 MHz Tap 1 4 dB 13 0 13 5 14 5 15 5 13 0 13 5 15 5 14 5 13 0 14 0 15 0 16 0 13 0 13 5 15 0 15 5 13 0 13 5 15 0 15 5 5 860 MHz Tap 5 8 dB 16 5 17 5 17 0 18 0 19 0 20 0 16 0 16 5 18 0 19 0 16 0 16 5 18 0 19 0 5 860 MHz Tap 9 12 dB 19 5 20 0 21 5 22 0 19 5 20 0 21 5 22 0 5 860 MHz Tap 13 16 dB 23 5 24 0 25 0 25 5 Isolation tap tap 5 40 MHz dB gt 32 0 gt 32 0 gt 30 0 gt 30 0 gt 30 0 40 470 MHz dB gt 32 0 gt 32 0 gt 30 0 gt 30 0 gt 30 0 470 860 MHz dB gt 30 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 Isolation out tap 5 40 MHz dB gt 26 0 gt 26 0 gt 20 0 40 470 MHz dB gt 26 0 gt 26 0 gt 20 0 Terminal Terminal 470 860 MHz dB gt 22 0 gt 22 0 gt 20 0 Return loss tap 5 40 MHz dB gt 32 0 gt 32 0 gt 30 0 gt 30 0 gt 30 0 40 470 MHz dB gt 32 0 gt 32 0 gt 30 0 gt 30 0 gt 30 0 470 860 MHz dB gt 30 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 Shielding efficiency VHF UHF dB gt 75 0 gt 75 0 gt 75 0 gt 75 0 gt 75 0 Power pass Yes Yes Yes No No Connectors F connector F connector F connector F connector F connector Certification CE CE CE CE CE Impedance Ohm 75 75 75 75 75 Weight kg 0 183 0 183 0 205 0 595 0 615 Dimensions h x d x w mm 54 x 42 x 84 54 x 42 x 84 54 x 42 x 107 78 x 44 x 242 78 x 44 x 24
53. 0 455 0 455 Dimensions H x D x W mm 152 x 51 x 355 152 x 51 x 253 105 x 43 x 196 138 iy MK A A SAT line amplifier Technical data Triax TMS 8 4 2 1 launch amplifiers Get a good head start With a TMS launch amplifier you can ensure you will get as much as possible out through of your cables TMS 8 AMPP IF amplifiers External power supply TYPE Part No TMS 8 AMPP 300425 TMS 44 AMP 300305 TMS 2 AMP TMS 2 AMP 300275 Sat line amplifier 300401 Number of inputs 8 SAT 4 SAT 2 SAT 1 SAT Number of outputs 8 SAT 4 SAT 2 SAT 1 SAT Connectors F con female female female female Frequency range SAT MHz 950 2200 950 2150 950 2150 950 2300 Frequency range TER MHz Return path switchable MHz Return path TER MHz Gain SAT 950 2150 MHz dB 32 36 38 30 16 20 4 dB slope Gain TER forward dB Noise figur SAT dB lt 16 0 lt 10 0 lt 5 0 Noise figur TER dB Adjustable attenuator SAT dB 0 20 0 20 0 10 Adjustable attenuator TER dB Equalizer SAT dB 0 10 0 12 0 8 Equalizer TER dB Isolation SAT to SAT dB gt 25 35 Isolation TER to SAT dB Max output level SAT IMD3 35 dB EUN 120 118 115 100 Max output level TER IMD3 60 dB dByV Return loss dB 10 10 10 10 Impedance input output Ohm 75 75 75 75 Supply voltage VDC 1
54. 0 5 0 2 0 3 0 1 5 1 5 1 0 2 0 Radio dB 4 0 2 0 1 5 1 0 DAB dB 4 0 2 0 1 5 1 0 SAT dB 5 0 4 0 3 0 4 0 Tap loss Return dB 10 0 11 0 15 0 20 0 TV dB 9 0 8 0 12 0 12 0 15 0 15 0 20 0 20 0 Radio dB 12 0 12 0 15 0 20 0 DAB dB 12 0 12 0 15 0 20 0 SAT dB 8 0 12 0 16 0 20 0 Return loss Return dB gt 22 0 gt 42 0 gt 50 0 gt 44 0 TV dB gt 33 0 gt 35 0 gt 40 0 gt 36 0 gt 40 0 gt 31 0 gt 38 0 gt 30 0 Radio dB gt 33 0 gt 40 0 gt 40 0 gt 38 0 DAB dB gt 33 0 gt 40 0 gt 40 0 gt 38 0 SAT dB gt 35 0 gt 30 0 gt 24 gt 20 0 Connectors TV lIEC male lIEC male lIEC male lIEC male Radio IEC female lIEC female IEC female lIEC female SAT F female F female F female F female DC through Standards CE Impedance Ohm 1D 75 75 75 Weight kg Dimensions mechanical mm O60 O60 O60 O60 Remarks Please refer to page 234 for cover frame and terminators 229 Triax GRID style outlets A flexible combine yourself range for domestic and system applications Single outlets for full frequency range with IEC or F connector Diplex TV radio outlets with IEC connector Triplexed TV radio SAT outlets with IEC and F connector Quad TV radio SAT 1 SAT 2 outlets with IEC and F connector The system also includes CAT 5E RJ 11 twin RCA and twin loudspeaker units please ask our sales department for more information GRID style outlet housing Technical data on GRID style in outlets
55. 0 8 lt 0 8 lt 0 8 40 470 MHz dB lt 1 3 lt 1 3 lt 1 3 lt 1 3 lt 1 3 470 750 MHz dB lt 1 8 lt 1 8 lt 1 8 lt 1 8 lt 1 8 750 862 MHz dB lt 2 2 lt 2 2 lt 2 2 lt 2 2 lt 2 2 Tap loss output 5 40 MHz dB 23 0 1 0 26 0 1 0 29 0 1 0 32 0 1 0 35 0 1 0 40 470 MHz dB 23 0 1 0 26 0 1 0 29 0 1 0 32 0 1 0 35 0 1 0 470 750 MHz dB 23 0 1 5 26 0 1 5 29 0 1 5 32 0 1 5 35 0 41 5 750 862 MHz dB 23 0 1 5 26 0 1 5 29 0 1 5 32 0 1 5 35 0 1 5 Isolation out tap 5 40 MHz dB gt 26 0 gt 26 0 gt 26 0 gt 26 0 gt 26 0 40 470 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 gt 28 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 862 MHz dB gt 23 0 gt 23 0 gt 23 0 gt 23 0 gt 23 0 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 862 MHz dB gt 24 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 Return loss out 5 40 MHz dB gt 17 0 gt 17 0 gt 17 0 gt 17 0 gt 17 0 40 470 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 470 750 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 750 862 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100
56. 1 2 10 0 1 5 12 0 1 5 16 0 1 5 20 0 1 5 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 Isolation out tap 5 40 MHz dB gt 30 0 gt 25 0 gt 28 0 gt 32 0 gt 40 0 40 470 MHz dB gt 27 0 gt 25 0 gt 26 0 gt 30 0 gt 35 0 470 860 MHz dB gt 25 0 gt 22 0 gt 25 0 gt 25 0 gt 30 0 Return loss in out 5 40 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 40 470 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 470 860 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 Return loss tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 26 0 gt 26 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 23 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No Connectors F connector F connector F connector F connector F connector Certification CE CE CE Ce CE Impedance Ohm 75 75 75 75 75 Weight kg 0 063 0 063 0 063 0 063 0 063 Dimensions h x d x w mm 50x16x74 50x16x74 50x16x74 50x16x74 50x16x74 176 Triax taps HTT series 5 1000 MHz E KLASSE CLASS HTT 3 10 HTT 3 12 HIT 3 16 HTT 3 20 347310 347312 347316 347320
57. 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 34 2 35 8 37 1 38 8 40 2 G T LNB 0 7 dB dB K 14 2 16 0 17 3 19 2 20 6 X polarisation dB gt 2 gt 2 gt 2 gt 27 gt 27 Offset angle degrees 26 26 26 26 26 Elevation range degrees 10 50 10 50 10 60 10 60 10 60 45 80 45 80 Reflector type F D 0 6 Offset Offset Offset Offset Offset Beam width degrees 3 7 3 1 2 6 2 0 1 8 Windload 42 m s N 323 445 619 902 1222 Material Aluminium Aluminium Aluminium Aluminium Aluminium Finish Polyester powder Polyester powder Polyester powder Polyester powder Polyester powder coat coat coat coat coat Aluminium LNB holder mm O40 O25 O40 O25 O40 O40 O40 Mast dimension mm O32 60 O32 60 O40 95 O40 95 O40 95 Wall bracket optional extra optional extra optional extra optional extra e optional extra Remarks some types available without Triax logo please contact our sales department A wide range of different mounting brackets for the TD series dishes is also available see more detailed information on page 99 under mounting accessories Wall bracket J bracket S bracket 81 Triax TD bulk packed dishes Triax bulk solution Bulk solutions reduce costs and contribute considerably to the protection of the environment due to the heavy reduction of packaging costs Mini bulk with 3 5 dishes Three or five complete satellite dishes packed in one carton box Bulk with 50 100 or
58. 10x80 mm 73 153599 Grounding Block F F HiQ 210 Eee conn SEa galego bea 140370 Expansion bolts 8x100 mm 73 109812 GSM 900 Gel 890 960mHz mast bracket 29 e ge 153720 EC conn 3dB attenuator 196 E 109807 GSM 900 6el 890 960MHz mast win bracket 29 153721 IEC conn 6dB attenuator 196 109815 GSM 900 Gel 890 960mHz mast win bracket 29 317229 F 3153 00 A2 54 153722 EC conn 9dB attenuator 196 317228 E 3153 00 A3 54 153031 IEC Crimp Female 210 317236 F 334350 00 A2 54 153030 IEC Crimp Male 210 253 Contents from A to Z 339212 IFA 212 163 324684 MD 6587T Filter and testpoint 2 pcs box 158 336154 NT 130 241 198 339213 IFA 213 163 322250 MDA 3047 156 336150 NT
59. 12 24 volt powering High output capability with low noise Masthead amplifiers with saddle and clamp connections TA 34 amplifier Technical data on TA mast amplifiers with saddle and clamp connectors TA 34W TA 34C D band C D 333402 333438 Input 1 Channel Band 21 69 21 37 35 53 48 69 Gain dB 24 34 24 34 24 34 24 34 Noise figure dB lt 1 8 lt 1 8 lt 1 8 lt 1 8 Input 2 Channel Band Gain dB Noise figure dB Max output voltage 60 dB IMA dBuV 105 105 105 105 Numbers of in output 1 1 1 1 1 1 1 1 Voltage VDC 12 24 12 24 12 24 12 24 Power mA 40 40 40 40 DC throughpower No No No No Connector S amp C S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 0 175 Dimensions Height mm 79 19 79 79 Depth mm 62 62 62 62 Width mm 118 118 118 118 Remarks Wideband Groupband Groupband Groupband 42 TRIAX s TA masthead amplifier Masthead amplifiers with saddle and clamp connections Weatherproof housing Fully screened enclosure Unique mounting system Flexible 12 24 volt powering High output capability with low noise TA amplifier Triax TA masthead amplifier series Technical data on TA mast amplifiers with saddle and clamp connectors TA 9W TA 21W TA 24W 24W TA 25W 1W TA 24BB TA 30BB 3 way 3 way var cascade cas 2 way 333417 333466 333501 333451 Input 1 Channel Band 21 69 21 69 21 69 21 69 VHF UHF VHF UHF
60. 150149 Center conductor mm 1 13 1 02 1 02 Center conductor material Cu blank Cu blank Cu clad steel Isolation mm 4 8 4 8 4 8 Dielectric PE foamed PE foamed PE foamed Screen AL PET AL P AL AL P AL Copolymer um 25 12 25 9 12 9 9 12 9 Braid material 24x7x0 11 16x4x0 11 16x4x0 12 construction mm CuSn 5 4 CuSn 5 4 AL 5 4 coverage 80 1 gt 38 gt 40 Screening attenuation dB 90 105 75 90 75 90 Anti migration foil um 12 12 12 Outer sheath PE PE PE Minimum bending radius mm 35 70 35 70 35 70 Diameter mm 6 8 6 8 6 8 Application Outdoor Outdoor Outdoor ELECTRICAL DATA Impedance Ohm 75 75 75 Capacitance pF m 52 52 52 Velocity ratio 84 84 84 Center conductor dc resistance Ohm km 17 5 Outer conductor dc resistance Ohm km 11 5 Attenuation at 20 C 5 MHz dB 100m 1 4 1 5 1 5 50 MHz dB 100m 4 0 4 6 4 6 100 MHz dB 100m 5 8 200 MHz dB 100m 8 2 9 0 9 0 400 MHz dB 100m 11 7 800 MHz dB 100m 16 8 18 8 18 8 862 MHz dB 100m 17 7 1000 MHz dB 100m 19 0 21 1 21 1 1600 MHz dB 100m 24 5 2150 MHz dB 100m 29 0 30 8 30 8 2400 MHz dB 100m 30 7 32 8 32 8 Structural Return Loss SRL 5 470 MHz dB gt 35 0 gt 33 0 gt 28 0 470 862 MHz dB gt 28 0 gt 26 0 gt 25 0 862 2400 MHz dB gt 24 0 gt 22 0 gt 20 0 Approval EN 50117 CEI 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes Yes Yes Yes Burial Yes 204 Triax RG 11 Bedea cable for outdoor use Durable and effectively shielded quality c
61. 152010 152003 152004 Remarks with marking with marking with marking with marking Power plug Male power plug Female power plug Power coupling Type 12 grey Type 22 grey C4012 12 pcs Part No 1 pcs 153300 153310 153616 Remarks with pull relief with pull relief Power outlet point 2 way point 3 way point 4 way point Type 43 grey Type 74 grey Type 71 grey Part No 1 pcs 153320 153322 153340 Remarks for 3 round plug for 4 round plug with pull relief with pull relief 213 Triax outlet Attenuation in outlets Throughpass Connection Internal coupling EN coupling attenuation attenuation attenuation attenuation Attenuation between trunk Attenuation between trunk Attenuation between plug 2 outlet method input and trunk output input and plug or socket output and socket output Attenuation between the output outputs of two antenna sockets Trunk input Trunk input Trunk input Trunk input Plug Socket EA KO Plug Socket bie Plug Socket Trunk output Plug Socket Trunk output Aruk Quipu Trunk output Socket types Double antenna outlet Triple antenna outlet Triple antenna outlet Quadro antenna outlet sockets sockets sat sockets multimedia sockets Universal sockets suitable For individual satellite and For individual multimedia For use in some multiswitch for satellite terrestrial and SMATV installations and SMATV installations installations broadband cable CA
62. 160 x 45 x 20 Remember to order the specific channel IMA 3 52 dB DIN norm D45004 Technical data AS power supply TYPE ASA 02 Part No 324596 Mains input voltage V AC 230 10 Output DC V 15 Max output current mA 2200 Temperature range C 0 50 AS power supply Dimensions H x D x W mm 128 x 57 x 85 Accessories Description ASC 011 ASR 075 ASL 030 324587 324598 324599 Mounting frame 75 Ohm Rigid coaxial for 10 modules termination plug interconnection power supply cable d 119 ARM multiband amplifiers ARM multiband amplifiers ARM are a series of multiband amplifiers with up to 5 separate adjustable inputs one for each band ARM 404 ARM 455 Technical data ARM multiband amplifiers TYPE Part No ARM 423 324124 ARM 404 324121 ARM 486 ARM 455 324122 ARM 486 324123 Numbers of inputs 3 4 5 6 Input 1 Frequency range MHz 87 5 108 47 68 87 5 108 47 68 87 5 108 87 5 108 Input 1 Gain dB 4 24 17 32 14 34 16 36 Input 1 Noise figure dB 8 0 5 0 5 0 8 0 Input 2 Frequency range MHz 174 230 174 230 174 230 47 68 470 862 Input 2 Gain dB 14 34 17 32 14 34 16 36 Input 2 Noise figure dB 5 0 5 0 5 0 8 0 Input 3 Frequency range MHz 470 862 470 862 470 862 174 230 Inpu
63. 20 21 TDH Channel filter 110 140041 Mast bracket 38 mm straight 68 140011 Mounting pipes single angle long 67 301386 S 22 23 TDH Channel filter 110 132102 Mast bracket 42 mm universal 66 140005 Mounting pipes single straight 67 301387 S 24 25 TDH Channel filter 110 132008 Mast bracket 50 mm left 66 140118 Mounting pipes SR 2530 2B 67 301388 S 26 27 TDH Channel filter 110 132007 _Mast bracket 50 mm right 66 153633 Mounting tool for F Con 209 301389 S 28 29 TDH Channel filter 110 132006 Mast bracket 50 mm straight 66 322293 MRT 300 E2000 154 301390 S30 31 TDH Channel filter 110 133224 Mast bracket 25 38 28 322292 MRT 300 SC APC 154 301391 S32 33 TDH Channel filter 110 133223 Mast bracket 38 60 28 322291 MRT 300L E2000 154 301392 S34 35 TDH Channel filter 110 140051 Mast bracket for TD 110 96 322290 MRT 300L SC APC 154 301393 S 36 37 TDH Channel filter 110 140050 Mast bracket for Unique 96 322295 MRT 400 E2000 154 301394 S38 39 TDH Channel filter 110 140041 Mast clamp 68 322294 MRT 400 SC APC 154 301373 S 4 5 TDH Channel filter 110 140210 Mast top 28 mm 63 322297 MRT 50X E2000 154 301395 S 40 41 TDH Channel filter 110 140213 Mast top 38 mm 63 322296 MRT 50X SC APC 154 301374 S6 7TDH Channel filter 110 140214 Mast top 42 mm 63 322270 MS 100 out A B 0 no Pass 156 338300 E 7200 2 splitter 195 140215 Mast top 50 mm 63 322271 MS 101 out A B No Pass 0 156 301375 S8 9TDH Channel filter 110 322240 MCA 100 423 M
64. 200 dishes Complete satellite dishes packed on a pallet with all the accessories packed i separate carton boxes or in scantainers with backbracket and arm mastbrackets LNB brackets and screw sets in small bags TD bulk with single packed accessories TMB mini bulk dishes excl logo TD dishes incl Triax logo TMB dishes Part No TDS steel dishes Part No TMB steel dishes 122567 TDS 54 Bulk w single Ral 7035 200 pcs pll 122627 TMB 64 Ral 7035 5 pcs Carton box 122568 TDS 54 Bulk w single Ral 7016 200 pcs pll 122674 TMB 64 Ral 7016 5 pcs Carton box 122569 TDS 54 Bulk w single Ral 8012 200 pcs pll 122236 TMB 78 Ral 7016 5 pcs Carton box 122667 TDS 64 Bulk w single Ral 7035 100 pcs pll 122733 TMB 78 Ral 7035 5 pcs Carton box 122668 TDS 64 Bulk w single Ral 7016 100 pcs pll 122831 TMB 88 Ral 7035 3 pcs Carton box 122669 TDS 64 Bulk w single Ral 8012 100 pcs pll 122832 TMB 88 Ral 7016 3 pcs Carton box 122672 TDS 64 Bulk w single Ral 7030 100 pcs pll Part No TMB aluminium dishes 122749 TDS 78 Bulk w single Ral 7035 100 pcs pll 123731 TMB 78 Ral 7035 5 pcs Carton box 122754 TDS 78 Bulk w single Ral 7016 100 pcs pll 123732 TMB 78 Ral 7016 5 pcs Carton box 122764 TDS 78 Bulk w single Ral 8012 100 pcs pll 123831 TMB 88 Ral 7035 3 pcs Carton box 122737 TDS 78 Bulk w single Ral 7030 100 pcs pll 123832 TMB 88 Ral 7016 3 pcs Carton box 122867 TD
65. 24 V Releasable mast strap for secure fixing RF shielded and CE marked EN 50083 On each side of the chosen channel there will be 2 barred neighbouring channels in rest VHF UHF input SCA amplifier Technical data on SCA single channel amplifier with saddle and clamp connectors SCA SCA 2021 1 SCA 2032 1 SCA 2045 1 SCA 2056 1 SCA 2069 1 439 443 333220 333221 333232 333245 333256 333269 Input 1 Channel S38 21 32 45 56 69 Gain dB 28 28 28 28 28 28 Noise figure dB 4 0 4 0 4 0 4 0 4 0 4 0 Input 2 Channel Band Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Gain dB 1 1 1 1 1 1 Noise figure dB Max output voltage 60 dB IMA GEUN 116 116 116 116 116 116 Numbers of in output 2 1 2 1 2 1 2 1 2 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 30 30 30 30 30 30 DC throughpower Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Rest VHF UHF Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 0 175 0 175 0 175 Dimensions Height mm 19 79 79 79 79 79 Depth mm 62 62 62 62 62 62 Width mm 118 118 118 118 118 118 SCA 2024 1 SCA 2025 1 SCA 2026 1 SCA 2027 1 SCA 2028 1 SCA 2029 1 SCA 2030 1 Part No Type Part No Type Part No Type Part No Type Part No 333221 SCA 2031 1 333231 SCA 2041 1 333241 SCA 2051 1 333251 SCA 2063 1 333263 333222 SCA 2032 1 333232 SCA 2042 1 333
66. 3 and on the other hand for full adjacent channel load of TV bands Maintaining the latter control limits allows for any channel load with analogue and digital TV signals worst case complete channel load with analogue and digital TV channels Assigning only digital TV channels in the frequency range lt 606 MHz makes it possible to raise the output level of the house connection amplifier by up to 2 dB Simply Qp more simply Technical appendix 3 Planning and installation instructions 3 1 Permissible output level for house connection amplifiers multiple band amplifiers and postamplifiers It is always recommended to carry out these calculations on a Windows PC using e Triax Hirschmann Turboplaner III Order No 499 999 003 e AND by CDS Germany www cdsgmbh de e CACAO by PTE software www ptesoftware dk The following explanations can be an additional help for solving problems and for understanding the underlying relationships The permissible output level is dependent on e The required signal to noise ratio CTB CSO e The number of TV channels to be transmitted e The frequency distribution of the channels The signals of the FM radio band can be treated as a single TV channel if their levels are 6 8 dB below the level of the TV channels The 1st selection criterion is the number of TV channels to be transmitted 3 1 1 Maximum number of TV channels 10 MATV systems e Determine the permissible
67. 3 1 3 1 3 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 Power mA 40 40 40 40 30 DC throughpower No Switchable Switchable Switchable Switchable Connector S amp C S amp C S amp C S amp C S amp C Weight kg 0 230 0 230 0 230 0 230 0 230 Dimensions Height mm 108 108 108 108 108 Depth mm 50 50 50 50 50 Width mm 120 120 120 120 120 Remarks 39 Triax TA mast amplifier series TRIAX s TA masthead amplifier Masthead amplifiers with saddle and clamp connections Weatherproff housing Fully screened enclosure Unique mounting system Flexible 12 24 volt powering High output capability with low noise TA 13 amplifier Technical data on TA mast amplifiers with saddle and clamp connectors TA 13W TA 13A TA 13B TA 13C D TA 13E TA 13W 1W band A band B band C D band E 333400 333430 333433 333436 333439 333500 Input 1 Channel Band 21 69 21 37 35 53 48 69 35 69 21 69 Gain dB 13 13 13 13 13 13 Noise figure dB lt 1 9 lt 1 9 lt 1 9 lt 1 9 lt 1 9 lt 1 9 Input 2 Channel Band BI BII BIII Gain dB 1 0 Noise figure dB Max output voltage 60 dB IMA dBuV 105 105 105 105 105 105 Numbers of in output 1 1 1 1 1 1 1 1 1 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 15 15 15 15 15 15 DC throughpower No No No No No Switchable Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 0 175 0 175 0 175 Dimensions Height mm 19 79 79 79 79 19
68. 302456 Part No grey in box 303450 303455 303456 Inputs 2 x TV radio Outputs 2 x TV radio 1 x Radio 1xTV Frequency range TV MHz 47 862 87 5 108 47 862 Radio MHz SAT MHz Through loss TV dB Radio dB SAT dB Tap loss TV VHF dB 0 2 0 2 0 2 TV UHF dB 0 5 0 5 0 5 Radio dB Liniarity TV radio SAT dB Isolation SAT radio 5 65 65 862 dB SAT TV 5 65 65 862 dB SAT out dB Radio TV dB TV out dB Radio out dB Return loss TV EN 50083 4 dB Radio EN 50083 4 dB SAT EN 50083 4 dB Shielding factor VHF UHF dB SAT dB Connectors TV IlEC male IEC female IEC male Radio IEC female SAT DC through mA Yes Yes Yes Standards CE Impedance Ohm 75 75 75 Weight kg 0 165 0 125 0 125 Dimensions w x h x d mm 50x77x26 50 x 50 x 26 50 x 50 x 26 Remarks Please refer to page 233 for cover frame and terminators 224 HT 02 HT 01 Triax special outlets TRIAX special outlets TRIAX has a range of special outlets for e g loudspeaker and F connectors HT 03 Technical data on TD special outlets TYPE Part No white in bag Part No grey in bag Part No white in box Part No grey in box 303491 303492 303493 303481 303482 303491 303492 303493 303481 303482 Outputs Loudspeakers Loudspeakers Loudspeakers F connector F connector 1x2 pol 2 x2 pol 2 X 2 pol connectors connectors connectors Connectors TV F angle F angle Radio loudspeakers Din Din Din c
69. 323016 IFE 834 C 323037 Frequency range selected VHF I on RP off MHz 40 862 selected VHF I off RP on MHz 5 65 85 862 5 65 85 862 5 65 87 862 Gain forward Gain 862 MHz dB 21 30 34 Attenuator at input 2 dB steps dB 0 20 0 20 0 16 Attenuator elements interstage dB Gain return path Gain 60 MHz dB 1 5 18 1 5 25 26 Attenuator elements at input dB 0 3 6 9 50 Attenuator elements at output dB 0 10 Amplitude response forward 40 862 MHz VHF I on dB 1 9 1 5 1 5 Fix slope dB 1 qB 1 qB 1 qB Line equalizer at input dB 0 16 0 18 Line equalizer 2 3 dB steps dB 0 16 Slope interstage dB 0 7 Amplitude response return path 5 60 MHz dB 1 5 1 5 1 5 Equalizer element interstage dB Random noise Forward VHF I on dB 5 5 5 5 6 0 Return path VHF OE dB 6 0 6 0 6 0 Return loss 40 MHz 1 5 dB octave dB gt 14 gt 14 gt 14 Output level forward IMR2 IMR3 60 dB dBuv 100 113 105 115 112 118 CSO CTB 60 dB 42 ch flat dBuvV 97 100 101 100 104 103 CSO CTB gt 60 dB 42 ch Slope 0 7 dB dBuyV 99 101 103 102 106 105 Output level return path IMR2 IMR3 60 dB dBuV 102 113 102 113 102 113 RF connectors 75 Ohm Input F female F female F female Output F female F female F female Test point input bi directional dB Test point output directional dB Operating conditions Max RF level EMC dBuvV 110 110 110 Supply voltage V 230 10 230
70. 340121 MFC 121 DAB K12 13 TV FM 50 150099 RG11 LZW Double shielded 500 m roll 205 322222 JXP OT222 155 340151 MFC 151 SAT VHF UHF 50 133015 Rigging screw 1 4 69 322223 JXP OT223 155 340103 MFC103 i 49 364026 RMF 75 Quick connector 148 322224 JXP OT224 155 340104 MFC104 49 132203 Roof cover black 71 322225 JXP OT225 155 340105 MFC105 49 132202 Roof cover red ral 8012 71 322226 JXP OT226 155 340106 MFC106 49 364025 RTF 75 DC terminator for districom 148 848616 Key for TCC Cabinet door 123 150000 Mini cable Double shielded 100 m Plastic roll 203 364025 RTF75 DC Terminator 211 GE 68_ 322232 MLO1 Link Module Interstage 156 E MN 322234 MLO2 Link Module Retur 156 301371 S1 2 TDH Channel filter 110 324617 MA 617 Return path amplifier 158 300743 Modulator cable 1 5m w scart 111 301376 S 10 Ch 5 TDH Channel filter 110 322248 MA6510 156 300748 Modulator cable 15 cm 111 301381 12 13 TDH Channel filter 110 133262 Mast bracket 15x15 60 69 140116 Mounting pipes 30 50 mm 67 301382 S 14 15 TDH Channel filter 110 133252 Mast bracket 18x18 G60 69 140012 Mounting pipes double angle 67 301383 S 16 17 TDH Channel filter 110 132005 Mast bracket 38 mm left 66 140009 Mounting pipes double straight 67 301384 S 18 19 TDH Channel filter 110 132004 Mast bracket 38 mm right 66 140117 Mounting pipes MF 38 30 50 mm 67 301372 S2 3TDH Channel filter 110 132003 Mast bracket 38 mm straight 66 140010 Mounting pipes single angle 67 301385 S
71. 37 and band IV V ch 21 69 versions featuring high gain and channel selectivity With their excellent gain and excellent front to back ratios these aerials ensure superior TV reception The Yagi 6 aerial is only available in channel 21 69 versions The aerials are made of an aluminium magnesium and manganese alloy which is extremely resistant to sea fog and acid rain Yagi 6W Technical data Yagi6 Yagi10 Yagi10 Yagi 15 Yagii5 Yagi15 Yagi15 107205 107310 107317 107347 107348 107349 107350 Channel 21 69 21 37 21 69 21 47 28 56 36 69 21 69 Band BIV V BIV BIV V BIV V BIV V BIV V BIV V Elements pcs 6 10 10 15 15 15 15 Gain dBi 8 5 12 5 12 5 13 5 13 5 13 5 13 5 Front to back ratio dB 17 21 21 25 25 25 25 Beamwidth hor deg 25 23 23 21 21 21 21 Windload N 14 26 22 58 54 54 54 Weight kg 0 45 0 70 0 65 0 80 0 77 0 77 0 77 Material Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 718 1182 975 width mm 260 350 350 Connector F con F con F con F con F con F con F con Remarks 18 Yagil 6 Gain ag Yagi 6 6 elem wideband Yagi 10 10 elem The Yagi 18 channelized aerial is designed for the highest gain and F B ratio within a narrow frequency range Yagi 18 channelized covers 3 to 7 chan nels It simultaneously enhances the wanted and rejects the unwanted signals giving superior reception quality
72. 470 750 MHz dB gt 14 0 gt 20 0 gt 20 0 gt 20 0 750 862 MHz dB gt 14 0 gt 20 0 gt 20 0 gt 20 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10A dB gt 66 gt 66 gt 66 gt 66 Power pass connection In Out In Out In Out In Out DC throughpass A VAC 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector Certification CE CE Ce Ce Impedance Ohm 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 192 Triax taps TLT series outdoor TLT 823 TLT 826 TLT 829 TLT 832 TLT 835 80256 80257 80258 80259 80260 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 Outputs pcs 8 8 8 8 8 Insertion loss 5 40 MHz dB lt 1 5 lt 1 2 lt 1 2 lt 1 2 lt 1 2 40 470 MHz dB lt 1 5 lt 1 3 lt 1 3 lt 1 3 lt 1 3 470 750 MHz dB lt 2 2 lt 2 0 lt 2 0 lt 2 0 lt 2 0 750 862 MHz dB lt 2 5 lt 2 2 lt 2 2 lt 2 2 lt 2 2 Tap loss output 1 2 3 5 40 MHz dB 23 0 41 2 26 0 41 2 29 0 41 2 32 0 1 2 35 0 41 2 40 470 MHz dB 23 0 1 2 26 0 41 2 29 0 41 2 32 0 1 2 35 0 41 2 470 750 MHz dB 23 0 1 5 26 0 41 5 29 0 41 5 32 0 1 5 35 0 1 5 750 862 MHz dB 23 0 1 5 26 0 41 5 29 0 41 5 32 0 1 5 35 0 1 5 Isolation out tap 5 40 MHz dB gt 32 0 gt 30 0 gt 30 0 gt 35 0 gt
73. 470 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 470 860 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 Return loss tap 5 40 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 40 470 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 470 860 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No Connectors F connector F connector F connector F connector F connector F connector Certification CE CE EE CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg 0 046 0 046 0 046 0 046 0 046 0 046 Dimensions h x d x w mm 50x16x52 50x16x52 50x16x52 50x16x52 50x16x52 50x16x52 175 Triax taps HTT series 5 1000 MHz HTT 2 8 HTT 2 10 HTT 2 12 HTT 2 16 HTT 2 20 347208 347210 347212 347216 347220 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 2 2 2 2 2 Insertion loss in out 5 40 MHz dB lt 3 3 lt 2 5 lt 1 7 lt 0 9 lt 0 7 40 470 MHz dB lt 3 5 lt 2 5 lt 1 7 lt 0 9 lt 0 7 470 860 MHz dB lt 4 2 lt 3 2 lt 2 2 lt 1 2 lt 0 9 Tap loss in tap 5 40 MHz dB 8 0 1 0 10 0 1 0 12 5 1 0 16 0 1 0 20 0 1 0 40 470 MHz dB 8 0 1 0 10 0 1 0 12 0 1 0 16 0 1 0 20 0 1 5 470 860 MHz dB 8 0
74. 48 48 48 48 Width mm 115 115 115 115 115 115 Remarks 48 Triax MFC multi band mast combiners MFC range of mast combiners with F connector Improved attractive housing Releasable mast strap Mast or wall mounting F connector Wide range with 2 or 3 inputs and 1 output Switchable DC through power RF shielded and CE marked EN 50083 The series includes a range of filters developed to replace some of the earlier types in our product range supplied in blue mast box MFC Mast F connector Combiner Easy installation of MFC combiner filter MFC combiner filter housing Technical data on MFC mast combiners with F connectors MFC 101 MFC 102 MFC 103 MFC 104 MFC 105 MFC 106 340101 340102 340103 340104 340105 340106 Input 1 Band SAT SAT UHF UHF UHF VHF VHF UHF Channel IF IF IF IF 21 69 2 69 Through loss dB 3 0 3 0 2 0 2 0 4 0 1 0 Input 2 Band VHF UHF UHF VHF BIII UHF VHF FM Channel 2 12 21 69 2 12 5 12 21 69 Through loss dB 2 0 2 0 1 0 1 5 4 0 1 0 Input 3 Band VHF AM BI FM Channel 2 12 Through loss dB Ee 1 0 Input 4 Band Channel Through loss dB Stop band attenuation VHF BI dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 FM dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 BIII dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 UHF dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 SAT dB gt 50 gt 50 Numbers of in output 2 1 2 1 2 1 3
75. 490725 490726 Norm L 490725 590726 Pal 490725 591626 Modulator type VSB VSB Input level dBuV 15 25 15 25 Audio mode Mono A2 stereo Nicam Output channel K 2 69 K 2 69 frequency range MHz 47 862 47 862 Output level max dBuV 105 105 Output level attennuator dB 10 10 Spurious signals ref pict carrier C N dB gt 60 gt 60 Video input CVBS niveau Vpp 0 7 1 3 0 7 1 3 Audio input level V RMS 0 5 V RMS 0 5 V RMS Video S N ratio dB gt 54 gt 54 Audio input output 15 pol SUB D 15 pol SUB D Temperature operation GE 10 50 10 50 Weight standard module kg 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 Remarks Video audio cable 15 cm Part No 300748 Part No 300748 more connection Phone Sub D 150 cm Part No 300745 Part No 300745 cables on page 111 108 Controlling Triax TDH 700 headend E 5 ways to control your TDH 700 headend and free software for controlling available on www triax com Unique simple operation via On Screen Display OSD Programming via PC On location via OSD Controll and install software via NBOX and TDH Manager Internet Controll and install software via GSM modem and TDH Manager Controll and install software via telephone modem and TDH Manager please see the user manual to make the correct connection of the units and you can also read more on our website about the different solutions Programming via PC de N por
76. 5 40 MHz dB gt 28 0 gt 27 0 gt 29 0 gt 30 0 gt 30 0 40 470 MHz dB gt 28 0 gt 27 0 gt 29 0 gt 30 0 gt 30 0 470 750 MHz dB gt 28 0 gt 27 0 gt 29 0 gt 30 0 gt 30 0 750 862 MHz dB gt 28 0 gt 27 0 gt 29 0 gt 30 0 gt 30 0 Return loss out 5 40 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 40 470 MHz dB gt 19 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 470 750 MHz dB gt 19 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 750 862 MHz dB gt 19 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10 A dB gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In out In out In out In out In out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector Certification CE ce CE CE CE Impedance Ohm 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 191 Triax taps TLT series outdoor Outdoor trunk taps with frequency ranges from 5 to 1000 MHz All ports impedance 75 Ohm In out current passing 10 A 60 VAC The 100 dB RFI integrity is maintained by the use of tongue and groove design and with a stainless steel mesh RFI gasket Continual power through between input and output Aluminum alloy housing is finished with a baked acrylic pain
77. 5 30 0 1 5 1750 2150 MHz dB 13 0 2 0 15 0 42 0 20 5 2 0 24 0 2 0 30 0 2 0 2150 2400 MHz dB 14 0 2 5 16 0 42 0 21 0 42 0 24 0 2 0 30 0 2 0 Isolation 5 40 MHz dB gt 21 0 gt 21 0 gt 21 0 gt 21 0 gt 21 0 40 1000 MHz dB gt 21 0 gt 21 0 gt 21 0 gt 21 0 gt 21 0 1000 1750 MHz dB gt 21 0 gt 21 0 gt 21 0 gt 21 0 gt 21 0 1750 2150 MHz dB gt 21 0 gt 21 0 gt 21 0 gt 21 0 gt 21 0 2150 2400 MHz dB gt 21 0 gt 21 0 gt 21 0 gt 21 0 gt 21 0 Return loss in out 5 40 MHz dB gt 20 0 gt 30 0 gt 35 0 gt 30 0 gt 35 0 40 1000 MHz dB gt 23 0 gt 23 0 gt 25 0 gt 23 0 gt 25 0 1000 1750 MHz dB gt 20 0 gt 22 0 gt 20 0 gt 22 0 gt 20 0 1750 2150 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 2150 2400 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 Return loss tap 5 40 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 40 1000 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1000 1750 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1750 2150 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 2150 2400 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass In Out In Out In Out In Out In Out Connectors F connector F connector F connector F connector F connector Certification CE CE CE CE CE Impedan
78. 53 ch 55 69 51 490722 TDH 722 Master DVB S mono module FTA 101 fo a ees Sare be 121760 TDS 78 Single EUROLINE Ral 7035 80 333383 TMC 69 SAT 55 ie eee 121762 TDS 78 Single EUROLINE Ral 8012 80 370004 TMS 12 way bar 148 490725 TDH 725 AV VSB modulator mono PAL I Secam 108 122712 TDS 78 Single packed Ral 7016 78 370005 TMS 16 way bar 148 490726 TDH 726 AV VSB modulator stereo PAL Secam 108 490730 TDH 730 DVB C QAM TDT 306 858 MH 104 122710 TDS 78 Single packed Ral 7030 78 301501 TMS 17 AMP 138 sa ee ee 122718 TDS 78 Single packed Ral 7035 78 301504 TMS 17 PSU incl Mounting bracket 140 490731 TDH 731 DVB C QAM TDT 120 306 MHz 104 EAEE bea 122825 TDS 88 Bulk Ral 7016 100 pcs pll 82 301512 TMS 17x12C 130 z 122824 TDS 88 Bulk Ral 7030 100 pcs pll 82 301612 TMS 17x12T 131 256 Contents from A to Z 301516 TMS 17x16C 130 303683 TOU Cover plate 3 hole Off White 80x80mm 232 131020 Wall bracket 2 Legs 15 cm 65 301616 TMS 17x16T 131 303682 TOU Cover plate 3 hole White 80x80 mm 232 131030 Wall bracket 2 Legs 25 cm 65 301506 TM
79. 55 0 55 Dimensions H x D x W mm 124x51x253 124x51x253 152x51x253 210x511x257 210x51 x257 132 Triax TMS 9xP multiswitches TMS 9xC and 9XP multiswitches offer a flexible and cost efficient system for providing two position satellite distribution in small and medium sized networks The system s uniqueness in design and performance makes community networks attractive even in buildings with only 2 or 3 households TMS 9X8P TMS 9X16P POT EE EEE iL Gh amp EA amp b bo ba bo ZG iat Je d Bie m TZ l A bn E Ga EO e TMS 9X4P a EE EET Technical data Terminated multi switches with 8 polarities 1 terr input With power supply TYPE TMS 9x4P TMS 9x6P TMS 9x8P TMS 9x12P TMS 9x16P Part No EU plug 300344 300346 300348 300342 300347 Part No UK plug 300354 300356 300358 300352 300357 Number of inputs 8 SAT 1 TER 8SAT 1 TER 8SAT 1TER 8SAT 1TER 8SAT 1 TER Subscriber outputs 4 6 8 12 16 Connectors F con female female female female female Frequency range SAT MHz 950 2150 950 2150 950 2150 950 2150 950 2150 Frequency range TER MHz 47 862 47 862 47 862 47 862 47 862 Gain SAT dB 2 2 2 D 0 Gain TER dB 2 2 2 4 2 Isolation LNB to LNB dB Isolation TER to SAT dB 28 28 28 30 30 Isolation SAT to TER dB 30 30 30 30 28 Isolation cross polarisation H V dB 28 28 28 25 25
80. 68 Combi 57 IZ 5 12 Ch 21 68 Gai Gain i i Combi 20 Combi 57 26 UFO Marine digital Triax UFO aerial VHF UHF digital UFO Marine digital The antenna has been surface treated to resist corrosion from salt water for many years Available with special bracketry for easy mounting on sailing boats and power boats UFO Home digital A small and discreet antenna which can be placed almost everywhere on the house roof or balcony Can be placed horizontally or vertically Technical data UFO Home digital UFO Marine UFO Marine Digital 109683 Digital 109680 Frequency range FM MHz 87 5 108 87 5 108 VHF MHz 174 230 174 230 174 230 UHF MHz 470 862 470 862 470 862 470 862 470 862 Channels FM 5 12 21 69 FM 5 12 21 69 21 69 21 69 5 12 21 69 Elements pcs 1 1 1 1 1 Opening angle _ ver hor deg 90 360 90 360 90 360 90 360 90 360 Windload N 5 5 5 5 5 5 55 5 5 Gain dB 28 28 16 16 28 Noise figure dB 2 0 2 0 2 0 2 0 2 0 Max output voltage GEUN 108 108 100 108 100 Supply voltage V 12 24 12 24 12 5 5 Power consumption mA 50 50 20 20 20 Dimensions length mm 325 325 325 325 325 width mm 255 255 255 255 255 height mm 65 65 65 65 65 Connector F connectors F connectors F connectors F connectors F connectors Power supply IFP 529 battery IFP 529 battery 230V Packing size 1 1 1 1 1 Bracketry Universal Centre mount Mast bracke
81. 8 8 Return loss TER outputs dB 8 8 8 8 Output level SAT IMD 35 dB EON 100 100 100 100 Impedance input output Ohm 75 75 75 75 Switching VDC 13 V 18 V 13 V 22 kHz 13 V 18 V 13 V 22 kHz 18 V 22 kHz DiSEqC 2 0 18 V 22 kHz DiSEqC 2 0 Toneburst Toneburst Supply voltage VDC 15 0 5 15 0 5 15 0 5 15 0 5 Power supply External power External power External power External power adaptor adaptor adaptor adaptor LNB power supply max A 1 3 1 3 1 3 1 3 Power link for amplifiers in the line Yes Yes Yes Yes Control LEDs Green for power Green for power Green for power Green for power Yellow for power link Yellow for power link Yellow for power link Yellow for power link Colourcoding of IF and TER inputs Yes Yes Yes Yes Temperature range AE 0 455 0 455 0 455 0 55 Dimensions H x D x W mm 125 x 55 x 355 125 x 55 x 355 215 x 55 x 355 215 x 55 x 355 130 e T T Triax TMS 17xT multiswitches Technical data ERTA Aa JEA Ad TMS17xC and 17XT multiswitches E Gezi E are rational solutions for building 4 satellite position systems for many subscribers AURRA d using relatively few components These cascadable systems can easily be extended eari ue E GA with more subscribers EEE Ei e rez ezi baa edi Zer TSE A e d aA zeu Med EE ed Sd ZO EZ T anit KA I dakak rri at era STEE 3s el S i TZ B Be d TMS 17X16T d TMS 17X8T Terminated multiswitche
82. 862 73 862 73 862 87 862 87 862 Test point dB 20 20 20 Packing size pcs 2 2 2 2 2 2 MA 617 return path amplifier TYPE MA 617 Part No 324617 Frequency range MHz 5 65 Gain MHz 17 Attenuation dB 20 Packing size pcs 1 Line power supply TYPE TRP Part No 416014 Power supply input V AC 230 10 Power supply output V AC 48 Max current A 1 25 Dimensions height x diameter mm 60 x 100 Power inserter with F con TYPE TPI 01 Part No 347001 Frequency range MHz 5 2400 Through loss 5 862 MHz dB gt 0 5 1000 2150 MHz dB gt 1 5 Max current A 2 5 Power V AC 65 Adaptor for Hxx amplifiers TYPE PG11 Ff 5 Part No 153580 A B Dimension mm HEX 20 x 72 5 TA Weight kg 0 046 158 7 E beree ufe ae b SEN i i HEF amplifier housing Triax distribution amplifiers HEF amplifiers Reliable flexible and cost efficient for big multi dwelling houses e ROB Return Path on Board without any external modules or pads means more flexibility and lower efforts in installation and logistics e Jumper matrixes to switch the fix elements for attenuation equalization and to select return path or VHF operation increase the reliability and reduce the logistics e High gain at the return path meets also special requirements in multimedia networks e Excellent electrical performance for lo
83. All TRIAX band aerials are provided with a light alloy metal boom made of 18 x 18 mm square tubes The dipole and the elements are made of 012 mm tube provided with strings to dampen vibrations and to prevent element resonance All band aerials are provided with brackets for aerial masts up to 60 mm Technical data Channel 2 2 elem Channel 3 3 elem Channel Channel Channel Channel Channel Channel 2 2 4 2 4 3 3 3 100022 100013 100014 100012 100033 100032 Channel 2 2 4 2 4 3 3 3 Band BI BI BI BI BI BI Elements pcs 2 3 3 2 3 2 Gain dBi 3 5 4 5 4 5 3 5 4 5 3 5 Front to back ratio dB 10 16 16 10 16 10 Beamwidth hor deg 36 34 34 36 34 36 Windload N 78 88 88 72 96 72 Weight kg 2 0 1 9 1 9 1 7 2 2 1 7 Material Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Dimensions length mm 1360 2180 2180 1260 1980 1260 width mm 3175 3180 3180 2730 2730 2730 Connector SC type SC type SC type SC type SC type SC type Type MT MT MT MT MT MT Remarks 2 part 1 2 part 1 1 2 part reflector reflector reflector Channel 2 2 elem Ch 3 Channel 3 2 elem Channel 4 b 4 elem Technical data Triax band I aerial VHF Channel 4 3 elem Channel Channel Channel 4 4 4 100016 100015 100044 Channel 4 4 4 Band
84. BI BI BI Elements DCs 2 3 4 Gain dBi 3 5 4 5 6 0 Front to back ratio dB 10 16 18 Beamwidth hor deg 36 34 32 Windload N 64 88 104 Weight kg 1 4 1 9 2 6 Material Aluminium Aluminium Aluminium Dimensions length mm 1160 1860 2650 width mm 2410 2410 2410 Connector SC type SC type SC type Type MT MT MT Remarks Ch 4 Channel 4 3 elem Triax band II aerial FM TRIAX band Il aerials are wide band aerials covering the entire frequency range from 87 to 108 MHz Band Il aerials are provided with a light alloy metal boom made of 18 x 18 mm square tubes The dipole and the elements are made of 012 mm tube provided with strings to damp vibrations and to prevent element resonance All aerials are provided with brackets for aerial masts up to 60 mm The MT D types feature dual reflectors FM 2 2 elem Technical data SS FM 8S 8 elem FM 4 4 elem FM 1 FM 2 FM 3 FM 4 FM 5 FM 5 100160 100161 100162 100163 100164 100184 Channel Band BII BII BII BII BII BII Elements pcs 1 2 3 4 5 5 Gain dBi 2 1 4 0 6 0 7 0 8 0 8 0 Front to back ratio dB D 10 16 18 20 20 Beamwidth hor deg 90 37 35 32 27 27 Windload N 28 40 56 64 80 80 Weight kg 0 3 1 1 1 3 1 5 1 7 1 7 Material Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Dimensions length mm 100 820 1188 1572 1932 1932 width mm 1500 157
85. C 5 MHz dB 100m 2 1 1 3 50 MHz dB 100m 6 0 4 2 200 MHz dB 100m 11 0 8 4 470 MHz dB 100m 17 5 12 8 600 MHz dB 100m 20 5 14 5 800 MHz dB 100m 23 1 17 5 1000 MHz dB 100m 26 2 20 3 1350 MHz dB 100m 31 9 23 6 1750 MHz dB 100m 35 8 27 3 2050 MHz dB 100m 38 7 29 5 2400 MHz dB 100m 41 9 32 0 Structural Return Loss SRL 5 470 MHz dB gt 30 0 gt 30 0 470 862 MHz dB gt 25 0 gt 25 0 862 2400 MHz dB gt 18 0 gt 20 0 Approval EN 50117 CEI 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes 202 Triax mini and multi cable for indoor use Technical data on indoor mini cable and 18 multi 5 cable Mini cable Double shielded White Grey PVC PVC 18 multi 5 cable Triple shielded White Grey Black PVC PVC PVC Part No Cardboard roll 100 m 150000 Cardboard roll 200 m 150075 Plastic reel 100 m on Plastic reel 250 m wood Plastic reel 500 m reel Center conductor mm 0 41 1 02 Center conductor material Cu blank Cu blank Isolation mm 1 9 4 8 Dielectric PEE foamed PEE foamed Screen AL PET AL PET AL um Braid material CuSn CuSn construction mm coverage 58 0 40 Screening attenuation dB Anti migration foil um Outer sheath PVC PVC Minimum bending radius mm 20 100 Diameter mm 3 6 i 20 5 Application Indoor Indoor ELECTRICAL DATA Impedance Ohm 7
86. Ch 50 53 Ch 31 53 Ch XX Gain dB 28 28 28 3 3 Noise figure dB lt 2 0 lt 2 0 lt 2 0 Input 2 Channel Band 23 60 Rest UHF Rest UHF Rest UHF Rest UHF Rest UHF Gain dB 28 10 4 10 10 4 10 24 24 Noise figure dB lt 2 0 lt 4 5 lt 4 5 lt 2 5 lt 25 Input 3 Channel Band Rest UHF BIA BI BIA BI VHF VHF VHF Gain dB 10 10 10 4 10 10 4 10 0 5 0 5 Noise figure dB lt 4 5 lt 4 0 lt 4 0 Input 4 Channel Band VHF Bill Ch X Gain dB 10 10 10 4 10 10 4 10 Noise figure dB lt 4 0 lt 4 0 lt 4 0 Input 5 Channel Band Rest BIII Gain dB 10 10 Noise figure dB lt 4 0 Max output voltage 60 dB IMA dBuvV 113 113 113 106 106 106 Numbers of in output 4 1 4 1 5 1 3 1 3 1 3 1 Voltage VDC 24 24 24 24 24 24 Power mA 80 75 75 35 35 35 DC throughpower Switschable Switschable Switschable Rest UHF Rest UHF Rest UHF on all inputs onallinputs on all inputs Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 5 0 5 0 5 0 5 0 5 0 5 Dimensions Height mm 122 122 122 122 122 122 Depth mm 55 55 55 55 55 55 Width mm 168 168 168 168 168 168 Remarks Multichannel Multichannel Multichannel Multichannel Multichannel Multichannel 45 Triax TMA mast amplifier series TRIAX s TMA mast amplifier Weatherproof housing Technical data on TMA mast amplifiers with saddle and clamp connectors Unique mounting system Flexible 12 24 volt powering High output capability with low noise Screened wit
87. Dimensions Height mm 90 90 90 69 69 69 Depth mm 48 48 48 55 55 55 Width mm 115 115 115 94 94 94 Remarks 56 Triax single channel mast filters TRIAX SCF range of filters combiners are based on state of the art technology Attractive blue mast housing High out of band rejection Excellent isolation Switchable through power Mast or wall mounting Releasable maststrap CE approved SCF single channel filter SCF 21 15 SCF 38 15 SCF 59 15 A3 A3 A3 331421 331438 331459 Input 1 Band UHF UHF UHF Channel 21 38 59 Through loss dB 3 0 3 0 3 0 Input 2 Band VHF rest UHF VHF rest UHF VHF rest UHF Channel Through loss dB 1 0 1 0 1 0 Stop band attenuation VHF rest UHF dB gt 20 gt 20 gt 20 Numbers of in output 2 1 2 1 2 1 DC throughpower Switchable Switchable Switchable VHF rest UHF VHF rest UHF VHF rest UHF Connector S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 Dimensions Height mm 117 117 117 Depth mm 50 50 50 Width mm 120 120 120 All SCF XX715 A3 single channel combiners Type Part No Type Part No Type Part No Type Part No SCF 21 15A3 331421 SCF 33 15A3 331433 SCF 45 15A3 331445 SCF 57 15A3 331457 SCF 22 15A3 331422 SCF 34 15A3 331434 SCF 46 15A3 331446 SCF 58 15A3 331458 SCF 23 15A3 331423 SCF 35 15A3 331435 SCF 47 15A3 331447 SCF 59 15A3 331459 SCF 24 15A3 331424 SCF 36 15A3 331436 SCF 48 15A3 331448 SCF 60 15A3 331460 SCF 25 15A3 331425 SCF 37 15A3 3
88. Grey Part No 153060 153061 760056 153057 Size Width mm 10 18 Lenght mm Material Plastic Rubber Rubber Rubber Weight kg Packing QTY per box DCs 1 1 1 1 Remarks Cartons of Single for ALPS Universal for 10 rolls pack LNB units F con Technical data on stitcher and clips Type Arrow T25 Clips 9 16 Clips 9 16 Stitcher Galv White Part No 153070 153071 153069 Size Width mm for T25 for T25 Lenght mm stitcher stitcher Material Steel Steel Weight Packing QTY per box 1000 1000 Remarks Cartons of Cartons of 10 boxes 10 boxes 74 Satellite reception Dishes TDE series TD series Basic series DAP series Elliptical perforated Unique LNB brackets and spare parts Universal LNB units Single twin quad quattro DiSEqC switches Polarmount and LNB covers Mounting accessories Tf 78 82 83 84 85 86 87 88 89 92 93 94 95 96 97 Well proven solutions for customers needs Not two customers are equal and therefore Triax is very flexible to find a solution that suits you as our customer When choosing a satellite dish we can offer different solutions when it comes to size material colour packing and accessories Aluminium or steel Our TD dishes are made of either alumin ium or steel Steel is the most preferred material to our customers Colours All dishes are available in different colours Naturally oth
89. M 102 MM F 2 splitter 2 splitter 3 splitter 3 splitter 338300 338106 338125 338130 338365 338366 Input 1 VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Channel Band 2 69 FM 2 69 FM 2 69 FM 2 69 FM 2 69 FM 2 69 FM Frequency range MHz 47 862 47 862 47 862 47 862 47 862 47 862 Splitter type Through loss VHF dB 4 0 3 4 6 0 8 0 3 5 3 5 UHF dB 4 0 3 8 6 0 9 0 3 5 3 5 Isolation dB gt 20 gt 20 gt 20 gt 20 TV FM dB DAB dB Number of outputs pcs 2 2 3 4 2 2 TV FM DAB DC throughpower Output 1 Switchable DC pass can No DC DC DC Output 2 Switchable be removed by No DC DC DC Output 3 cutting PCB No DC Output 4 DC Connector S amp C S amp C S amp C S amp C IEC IEC Weight kg Dimensions Height mm Depth mm Width mm Remarks Outdoor for Indoor Indoor Indoor IEC female IEC male mastmounting 195 Triax attenuators Variable attenuators 20 dB TRIAX variable attenuators are available in types for indoor as well as outdoor mounting DB 0 20 is provided with a small metal housing with IEC plug for direct connection to video or TV a a D7020 A1 DB 0 20R Triax 5020 Technical data on Triax attenuators D7020 A1 ZURA DB 0 20R1 753343 VA 20 F var 342000 342101 342250 316110 153600 Input 1 VHF UHF VHF UHF VHF UHF UHF VHF UHF Channel Band 2 69 FM 2 69 FM 2 69 FM Ch 21 33 43 60 2 69 FM Frequency range MHz 47 862 47 862 47 862 4
90. O40 O25 Mast dimension mm O32 60 O32 60 Wall bracket optional extra optional extra Remarks Double U bracket Double U bracket TRIAX Unique multi reception dish Ref val dB 37 00 Scale div dB 1 00 es es A 2 ao b wow N e D 86 TRIAX Unique multi reception dish gain It is quite obvious how the TRIAX Unique multi reception dish design retains gain even at large changes of azimuth beam angles where it really matters for multi satellite reception All TRIAX dishes have been wind tunnel tested according to ETSI standard ETS 300784 Satellite Earth Stations TVRO LNB brackets multi satellite reception Triax s range of LNB brackets and accessories for perfect installations Well designed LNB bracket in UV resistent plast and aluminium ensures stable and easy mounting e g TDE multi blocks 2 different heavy duty multifeed brackets for 2 up to 4 pcs of 840 mm LNBs is also available for the TDE series of dishes Duo blocks You can get 3 and 6 duo block for 40 mm LNBs is an elegant solution for reception from two satellite positions e g Eutelsat Hotbird and ASTRA Available in black and grey for the TDE TD and Basic series Flexi blocks Also a 3 to 10 Flexi blocks for two 40 mm LNBs is available for all 3 series Multi blocks A 3 to 20 Multi block for four 040 mm LNBs with min 4 degrees between the satellite positions is available for the TD and Basic series
91. Plastic Plastic Electro galv Electro galv Weight kg Packing QTY per box pcs 100 100 100 100 100 50 50 Remarks Cartons of Cartonsof Cartonsof Cartonsof Cartons of also available also available 10 boxes 10 boxes 10 boxes 10 boxes 10 boxes by the piece by the piece Technical data on screws Screw Screw Screw Screw Screw Screw Screw 140340 140350 140351 153580 140360 140380 140361 Size Diameter mm 6 8 8 8 10 10 10 Lenght mm 50 50 80 100 50 80 80 Material Surface treatment Electro galv Electro galv Electro galv Electro galv Electro galv Electro galv Electro galv Weight kg Packing QTY per box pcs 200 200 200 50 100 50 100 Remarks also available also available also available also available also available also available also available by the piece by the piece by the piece by the piece by the piece by the piece by the piece ATA 73 Cable strips tape clips and stitcher Technical data on cable strips Type SST 21 PLT 2S PLT 2S PLT 4S PLT 3H PLT 3H Black Black Black Black Black Black Part No 153065 712290 153067 153066 712296 153068 Size Diameter mm 80 48 48 102 76 76 Lenght mm 290 188 188 368 290 290 Height mm 3 6 4 8 4 8 4 8 7 6 7 6 Material SMO SMO SMO SMO SMO Weight kg Packing QTY per box pcs 100 1 100 100 1 100 Remarks Technical data on tape Type Tape Black self Cable grom Grey vulcanized met
92. Steel 5 x 35 steel 5 x 35 steel 5 x 35 steel Surface tratment mm Galv Electrogalv Electrogalv Electrogalv Weight kg Dimension box mm 360 x 130 x 40 360 x 210 x 40 360 x 150 x 40 Packing QTY pcs 1 1 1 1 64 Wall brackets Technical data on hot galvanized wall brackets 2 legs Wall bracket Wall bracket Wall bracket Wall bracket Wall bracket 2 leg 5 cm 2leg 15cm 2leg 25cm 2leg 35cm 2 leg 45 cm 131010 131020 131030 131040 131050 Mast diameter mm 30 50 30 50 30 50 30 50 30 50 Clearance from wall mm 50 150 250 350 450 Material Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 Technical data on hot galvanized wall brackets 3 legs Wall bracket Wall bracket Wall bracket Wall bracket Wall bracket 3leg 15cm S3leg 25cm S3leg 35cm S3leg 45cm 3leg 55 cm 131021 131031 131041 131051 131061 Mast diameter mm 30 50 30 50 30 50 30 50 30 50 Clearance from wall mm 150 250 350 450 550 Material Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 DIN IN IN Technical data on hot galvanized wall brackets 3 legs Wall bracket Wall bracket 3 leg 65cm 3leg 75 cm 131071 131081 Mast diameter mm 30 50 30 50 Clearance from wall mm 650 750 Material Galv steel Galv steel Weight kg Packing QTY pcs 1 1 NAN 65 Wall bracket set Triax s range of brackets f
93. TMS 9 AMP cascadable amplifier eee BIZ penne de GE H i A gw 8 BA gt ZOA LAN Technical data TMS 17 AMP cascadable amplifier IF amplifiers External power supply TYPE TMS 17 Amp TMS 9 Amp TMS 55 Amp Part No EU plug 301501 300365 300315 Part No UK plug 300335 Number of inputs 16 SAT 1 TER 8 SAT 1 TER 4 SAT 1 TER Power link Number of outputs 16 SAT 1 TER 8 SAT 1 TER 4 SAT 1 TER Power link Connectors F con female female female Frequency range SAT MHz 950 2150 950 2150 950 2150 Frequency range TER MHz 5 862 47 862 47 862 Return path switchable MHz 5 30 or 5 65 Return path TER MHz 5 65 passive Gain SAT 950 2150 MHz dB 18 24 14 20 25 2 2 2 Gain TER forward dB 17 17 2 17 2 Noise figur SAT dB lt 8 Noise figur TER dB lt Adjustable attenuator SAT dB 0 10 0 20 0 15 Adjustable attenuator TER dB 0 10 0 20 0 17 Equalizer SAT dB D or 6 switchable 5 fixed 5 fixed Equalizer TER dB 0 15 adjustable 2 15 adjustable 7 12 adjustable Isolation SAT to SAT dB 30 Isolation TER to SAT dB 22 Max output level SAT IMD3 35 dB EUN 110 110 110 Max output level TER IMD3 60 dB dByV 105 105 105 Return loss dB 10 10 10 Impedance input output Ohm 75 75 75 Supply voltage VDC 18 via power link 18 via DC plug or trunk Power supply External External External power adaptor power adaptor power adaptor Colourcoding of IF and TER inputs Yes Yes Yes Temperature range GE 0 455
94. TV system PAL G PAL AN 1 A V WL 2 Modulator type DSB UHF DSB UHF NA NA UHF output channel 21 69 4 21 69 4 NA NA UHF output level dBuV 85 5 85 5 NA NA Output power dBm NA NA NA 10 Modulation NA NA NA FM Receiver sensitivity dBm NA NA NA 80 Receiver noise figure dB NA NA NA 3 5 Output frequency range MHz 470 862 470 862 NA NA Transmission frequency GHz NA NA NA 2 4 2 483 4 ch Operational range free field m NA NA NA 80 100 Audio carrier MHz 5 5 6 5 NA NA Integrated mic Yes Yes Yes Yes S N ratio dB gt 48 gt 48 gt 48 gt 48 Image sensor 1 3 inch CMOS 1 3 inch CMOS 1 3 inch CMOS 1 3 inch CMOS Lens E 1 8 6 0 mm 64 F 1 8 6 0 mm 64 F 1 8 6 0 mm 64 F 1 8 6 0 mm 64 Wide angle Wide angle Wide angle Wide angle Resolution lines 380 380 380 380 Number of pixels pixels 628 x 582 628 x 582 628 x 582 628 x 582 Min illumination LUX 3 3 3 3 Built in light NA NA NA NA Auto iris electronics sec 1 60 1 5000 1 60 1 5000 1 60 1 5000 1 60 1 5000 Operation conditions Weatherproof outdoor aluminium housing Power consumption mA 120 120 120 300 Operating voltage VDC 12 12 12 12 Power inserter supply incl Yes Yes Yes Yes Power inserter Insertion loss VHF UHF in out dB 4 4 NA NA VHF UHF in out dB 20 20 NA NA In out dB 0 1 0 1 NA NA Max current A 0 8 0 8 NA NA Dimensions camera only mm 105 x 50 x 115 105 x 50 x 115 105 x 50x 115 155 x 60 x 52 1 AN Audio video via RCA phono cable included 2 A V WL Audio video from r
95. VHF Ill ID 174 182 175 25 181 25 IE 182 190 183 25 189 25 IF 190 198 191 25 197 25 IG 198 206 199 25 205 25 H 206 214 207 25 213 25 lJ 214 222 215 25 221 25 VHF 41 00 49 00 47 75 41 25 e 49 00 57 00 55 75 49 25 C 57 00 65 00 63 75 57 25 C1 53 75 61 75 60 50 54 00 VHF Ill 5 174 75 182 75 176 00 182 50 6 182 75 190 75 184 00 190 50 7 190 75 198 75 192 00 198 50 8 198 75 206 75 200 00 206 50 9 206 75 214 75 208 00 214 50 10 214 75 222 75 216 00 222 50 VHF III 174 182 175 25 181 75 182 190 183 25 189 75 6 190 198 191 25 197 75 T 198 206 199 25 205 75 8 206 214 207 25 213 75 9 214 222 215 25 221 75 249 Technical appendix 7 Colour and broadcasting systems by country Colour Stereo Subtitles Colour Stereo Subtitles system system Albania B G PAL Netherlands B G PAL FM FM Teletext Argentina N PAL N New Zealand B G PAL Nicam Teletext Australia B G PAL FM FM Teletext North Korea D K SECAM Austria B G PAL FM FM Teletext Norway B G PAL Nicam Azores Portugal B PAL Pakistan B PAL Bahamas M NTSC Paraguay N PAL Bahrain B PAL Peru M NTSC Barbados M NTSC Philipines M NTSC Belgium B G PAL Nicam Teletext Poland D K PAL Teletext Bermuda M NTSC Portugal B G PAL Nicam Teletext Brazil M PAL M MTS Romania G PAL Bulgaria D SECAM Russia D K SECAM Canada M NTSC MTS CC Saudi Arabia B SECAM Canar
96. VHF UHF Log periodic UHF 24 Combi 2 10 Triax Combi aerial VHF UHF The combined aerials are designed for VHF UHF reception and ensure perfect reception of the signals All types are made of high quality material and are extremely resistant to sea fog and hostile weather conditions The aerials are provided with mast brackets designed for masts up to 60 mm g b E Combi 12 Window Combi 13 Technical data Combi 1 6 108681 Combi 12 Window 108937 Combi 12 Mast 108936 Combi 13 108692 Combi 2 10 108682 Channel 2 4 21 69 2 12 21 69 2 21 60 3 4 21 60 5 12 21 60 5 12 21 60 Band BIII BIV V VHF BIV V BI BIV V BI BIV V BIII BIV V BIII BIV V Elements pcs 1 6 1 4 8 2 10 2 10 4 8 4 8 Gain VHF dBi 0 0 0 0 4 0 2 0 2 0 4 0 4 0 UHF dBi 8 5 8 5 8 0 12 0 8 0 12 0 4 0 9 0 4 0 9 0 Front to back ratio hor dB 0 0 0 0 12 0 9 0 9 0 12 0 12 0 ver dB 15 0 15 0 12 0 12 0 15 0 15 0 Beamwidth hor deg 40 35 35 35 32 32 ver deg 25 15 23 23 15 15 Windload N 43 50 80 80 34 34 Weight kg 1 70 1 20 2 50 2 50 0 75 0 75 Material Alu Alu Alu Alu Alu Alu Dimensions length mm 805 966 2117 2117 866 866 width mm 1240 1950 2730 2730 855 855 Connector SC type SC type SC type SC type SC type SC type Type MTH MTH MTH MTH MTH MTH Remarks Combi 1 6 Ch 2 4 5 12 Ch 21 69 ES muna Ez
97. XX single channel notch stop filters Type Part No Type Part No Type Part No Type Part No SCS 7000 21 314021 SCS 7000 33 314033 SCS 7000 45 314045 SCS 7000 57 314057 SCS 7000 22 314022 SCS 7000 34 314034 SCS 7000 46 314046 SCS 7000 58 314058 SCS 7000 23 314023 SCS 7000 35 314035 SCS 7000 47 314047 SCS 7000 59 314059 SCS 7000 24 314024 SCS 7000 36 314036 SCS 7000 48 314048 SCS 7000 60 314060 SCS 7000 25 314025 SCS 7000 37 314037 SCS 7000 49 314049 SCS 7000 62 314062 SCS 7000 26 314026 SCS 7000 38 314038 SCS 7000 50 314050 SCS 7000 63 314063 SCS 7000 27 314027 SCS 7000 39 314039 SCS 7000 51 314051 SCS 7000 64 314054 SCS 7000 28 314028 SCS 7000 40 314040 SCS 7000 52 314052 SCS 7000 65 314065 SCS 7000 29 314029 SCS 7000 41 314041 SCS 7000 53 314053 SCS 7000 66 314066 SCS 7000 30 314030 SCS 7000 42 314042 SCS 7000 54 314054 SCS 7000 67 314067 SCS 7000 31 314031 SCS 7000 43 314043 SCS 7000 55 314055 SCS 7000 68 314068 SCS 7000 32 314032 SCS 7000 44 314044 SCS 7000 56 314056 SCS 7000 69 314069 58 TRIAX range 80000 stacking combiner TRIAX has HF tight stacking filters for combining 2 or 4 UHF aerials ch 21 69 The filters are mounted close to the aerial on the mast mounting delivered with the combiner The filters are available in a HF tight diecast aluminium housing with splashproof design IP55 and cable entry takes place by means of PG11 connections Series 800 stacking combiner TRIAX Series 700
98. Zei Technical data on TDS Euroline steel dishes TDS 54 TDS 64 TDS 78 TDS 88 TDS 110 50 x 56 cm 60 x 65 cm 70 x 78 cm 85 x 95 cm 100 x 105 cm Part No Light grey Ral 7035 121560 1221660 121760 121860 121960 Grey Ral 7030 Anthracite Ral 7016 121661 121761 121861 121961 Red Ral 8012 121662 121762 121862 121962 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 34 2 35 8 37 1 38 8 40 2 G T LNB 0 7 dB dB K 14 2 16 0 17 3 19 2 20 6 X polarisation dB gt 2 gt 2 gt 2 gt 27 gt 2 Offset angle degrees 26 26 26 26 26 Elevation range degrees 10 50 10 50 10 60 10 60 10 60 45 80 45 80 Reflector type F D 0 6 Offset Offset Offset Offset Offset Beam width degrees 3 3 1 2 6 2 0 1 8 Windload 42 m s N 323 445 619 902 1222 Material Galv steel Galv steel Galv steel Galv steel Galv steel Finish Polyester powder Polyester powder Polyester powder Polyester powder Polyester powder coat coat coat coat coat Aluminium LNB holder mm O40 O25 O40 O25 O40 O40 O40 Mast dimension mm O32 60 O32 60 O40 95 O40 95 O40 95 Wall bracket optional extra optional extra optional extra optional extra e optional extra Remarks some types available without Triax logo please contact our sales department TD duo block 80 TD flexi block We can supply a wide range of different LNB brackets for
99. active 950 2150 active Frequency range TER MHz 5 862 active 5 862 active 5 862 active 5 862 active 5 862 active Return path TER MHz 5 605 passive 5 65 passive 5 65 passive 5 65 passive 5 65 passive Gain SAT with 5 dB slope dB 3to2 1 0 3to2 1 0 3to2 1 0 3 3 Gain TER dB 9 9 9 9 9 Insertion loss trunkline SAT dB 2 2 0 3 2 0 4 2 0 4 2 0 4 2 0 Insertion loss trunkline TER dB 4 1 0 4 1 0 5 1 0 5 1 0 5 1 0 Isolation LNB to LNB dB 35 35 35 35 35 Isolation TER to SAT dB 23 23 23 23 23 Isolation SAT to TER dB 28 28 28 28 28 Isolation cross polarisation H V dB 28 28 28 28 28 Isolation out out TER dB 28 28 28 28 28 Isolation out out SAT dB 30 30 30 30 30 Return loss SAT inputs dB 13 13 13 13 13 Return loss SAT outputs dB 8 8 8 8 8 Return loss TER inputs dB 11 11 11 11 11 Return loss TER outputs dB 8 8 8 8 8 Output level SAT IMD3 35 dB GEUN 100 100 100 100 100 Output level TER IMD3 60 dB GEUN 88 88 88 88 88 Impedance input output Ohm 75 75 75 75 75 Switching VDC 14V 18V 14 V 22 kHz 18 V 22 kHz DiSEqC 2 0 Supply voltage VDC 15 1 0 15 1 0 15 1 0 15 1 0 15 1 0 Power supply External power External power External power External power External power adaptor adaptor adaptor adaptor adaptor Max current pass per F connector mA 500 500 500 500 500 Colourcoding of IF and TER inputs Yes Yes Yes Yes Yes Temperature range C 0 55 0 55 0 55 0
100. can be used with plug in optimised elliptical feed LNBs for maximum performance or with standard universal LNBs using a 40 mm feed clamp Available in perforated or solid zinc coated steel both dishes come with the following features e Tilt movement skew adjustment e Integrated spirit level on region 1 for correct alignment first time e Polyester powder coated reflector and bracketry Pole or pole wall mounting e Packed in 1 pcs single pack Elliptical reg 2 solid 72 x 58 cm Part No Anthracite Ral 7016 124225 124351 124352 124353 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 10 70 GHz dBi 32 3 32 3 35 2 35 2 12 75 GHz dBi 33 7 33 7 36 7 36 7 G T LNB 0 7 dB dB K X polarisation dB Offset angle degrees 22 6 22 6 23 9 23 9 Elevation range degrees 0 60 0 60 10 70 10 70 Reflector type F D 0 6 Offset Offset Offset Offset Beam width degrees Windload 42 m s N Material Steel Steel Steel Steel Finish Polyester Polyester Polyester Polyester powder coat powder coat powder coat powder coat LNB holder mm O40 or O40 or O40 or O40 or Plug in LNB Plug in LNB Plug in LNB Plug in LNB Mast dimension mm O30 50 O30 50 M30 40 O30 40 Wall bracket optional extra optional extra optional extra optional extra Remarks Single U bracket Single U bracket Double U bracket Double U bracket
101. changed whenever needed Terminated multiswitches with 16 polarities 1 terr input External power TDM 504 364504 TDM 506 364506 TDM 508 364508 Number of inputs 4x SAT 1x TER 4x SAT 1x TER 4x SAT 1x TER Number of outputs 4x SAT 1x TER 4x SAT 1x TER 4x SAT 1x TER Subscriber outputs 4 6 8 Connectors F con female female female Frequency range MHz 950 2200 950 2200 950 2200 Through loss TER dB 2 90 1 2 0 1 29 cascade SAT dB 3 0 1 45 1 45 1 Tap loss TER passive dB 16to 18 5 1 tap 1 to 4 22 to 24 2 tap 1 to6 22 to 24 2 tap 1 to 8 SAT active dB 3 to 5 2 1 to 5 2 1 to 5 2 Isolation dB gt 20 dB min gt 20 dB min gt 20 dB min gt 30 dB typ gt 30 dB typ gt 30 GB typ Isolation subscriber output dB gt 25 dB min gt 25 dB min gt 25 dB min gt 30 dB typ gt 30 dB typ gt 30 GB typ Impedance Ohm 75 75 75 Return loss SAT TER dB gt 10 2 12 gt 10 gt 12 gt 10 2 12 Max input level dBuv 100 100 100 Output level SAT dBuvV 100 100 100 Noise figure dB lt 7 lt 7 lt 7 Power consumption from receiver mA lt 90 lt 90 lt 90 Power supply voltage VDC 15 1 15 1 15 1 Power supply current mA lt 15 lt 15 lt 15 Power connector mm ZKIA ZKIA ZKIA Control V 11 5 to 14 V H 16 19 V V 11 5t014V H 16 19V V 11 5 to 14 V H 16 19 V Hi 22 kHz 0 6 2 H
102. dB 2 0 3 0 3 0 3 0 1 0 Input 3 Band UHF UHF rest UHF rest UHF Channel 21 69 1ch Y Through loss dB 2 0 3 0 2 0 2 0 Input 4 Band UHF Channel 1 ch YY Through loss dB 3 0 Stop band attenuation VHF BI dB gt 22 gt 22 gt 20 FM dB Bill dB gt 20 UHF dB gt 10 gt 15 gt 15 gt 20 SAT dB Numbers of in output 2 1 4 1 3 1 3 1 2 1 DC throughpower 1 of the rest inputs VHF UHF Connector S amp C S amp C S amp C S amp C S amp C Weight kg 0 2 0 2 0 2 0 2 0 2 Dimensions Height mm 90 90 90 90 90 Depth mm 48 48 48 48 48 Width mm 115 115 115 115 115 Remarks UHF channel UHF channel UHF channel please see combiner combiner combiner next page 52 TRIAx FILTER TYPE y UHF CH XX Rest VHF UHF OUT Of SE OF OF Eile Ero at Triax multi channel mast combiners TRIAX DCF range of filters combiners When you are using the DCF UHF series with the XX and YY channels you must remember that there must be 2 unused channels between your specified XX and YY UHF channels DCF Double Channel Filter Se zi DCF double channel filter housing GZ ZE Za UE ek e dd D e 2 P E F XXYY 00A1 Technical data on DCF multi channel mast combiners with saddle and clamp connectors DCF XXYY DCF XXYY DCF XXYY F XXYY F XXYY F XXYY 15A2 15A3 15A4 00A1 OOA2 00A3 317400
103. deviations the following rules of thumb can help to obtain a rough approximation for the adjustment 1 Select the catalog values corresponding to the highest channel frequency 2 Fora channel pattern with twice the number of channels specified in the catalog reduce the output level by about 3 dB This software is only available in deutsch 245 Technical appendix 3 Planning and installation instructions continued from last page If the frequency band contains only one half of the number of channels with constant channel spacing it is possible to raise the output level by 3 dB If the configuration lies somewhere in between these extremes it is possible to make a rough interpolation c Maximum output level for frequency pre compensation line equalizer A frequency pre compensation value for example of 10 dB using a line equalizer permits driving the amplifier approximately 2 dB higher This value can also be treated as output reserve It should be noted however that the signal to interference ratio at low frequencies will deteriorate by the amount of the compensation attenuation For extreme cases optimization by a planning specialist is therefore required d Permissible output level when cascading amplifiers For cascades reduce the output level by 3 dB each time you double the number of cascaded amplifiers 3 2 Radiated interference power and max operating level The radiated interference pow
104. ei 82 590726 TDH AV VSB modulator Nicam 108 334203 TFS 715 3 194 123647 TDA 64 Bulk Ral 8012 100 pes pl __82 590767 TDHAV VSB modulator Nicam 108 334204 TFS 715 4 194 123666 TDA 64 Bulk w single Ral 7035 100 pcs pll 82 r aA e a a aiG 490738 TDH DVB S FM Modulator Cl 105 133009 Thimble 3 mm 69 singe na 490737 TDH DVB S EM Modulator FTA 105 133008 Thimble 5 mm 69 123660 TDA 64 Single EUROLINE Ral 7035 81 490739 TDH DVB Slave FM Modulator 105 80225 TLS 102 187 123662 TDA 64 Single EUROLINE Ral 8012 81 e E ea iek ea 490772 TDH FM Amplifier 107 80226 TLS 103 187 a ga T ae a Ga ba Ga 490736 TDH FM Modulator 105 80263 TLS 103S 187 ce mre nae re B da bee 590703 TDH Master DVB S Nicam module Cl 101 80236 TLS 108 187 single packed a 590743 TDH Master DVB S Nicam module Cl 101 80237 TLS 112 187 123748 TDA 78 Bulk Ral 7035 100 pcs pll 82 123747 TDA 78 Bulk Ral8012 100 Toll 82 590747 TDH Master DVB S Nicam module FTA 101 80238 TLS 116 187 o gra Se e b d ge z ko al Sa 590723 TDH Master DVB S Nicam module FTA 101 80261 TUT 204 188 bed Gr F w Sien de See be pes do 7 590713 TDH Master DVB T Nicam module Cl 102 80243 TLT 208 188 er EO a Onc ENE SO d 6 pes pi a 590763 TDH Master DVB T Nicam module CI 102 80228 TLT 211 188 EE ZA r9 onge E zk 590715 TDH Master DVB T Nicam module FTA 102 80234 TLT 214 188 123760 TDA 78 Single EUROLINE Ral 7035 81 123762 TDA 78 Sinole EUROLINE Ral 8012 81 590765 TDH Master DVB T Nicam module F
105. for terminal equipment Protection class 2 according to IEC 60417 5172 for components with power connection 230 V 243 Technical appendix 2 Technical data in the catalogue 2 1 Characteristic impedance Unless otherwise expressly mentioned all technical data in the catalogue refer to a 75Q impedance for the RF connections 2 2 Operating temperature All passive units in the catalogue can be used within an operating temperature range of 20 C to 60 C The mains operated units meet the requirements of the EN 60065 standard within the temperature range from 20 C to 50 C Operability of these units is nevertheless also maintained fully in the temperature range from 20 C to 60 C Individual units that deviate with regard to the above operating temperature range are specifically mentioned 2 3 Mains voltage All mains operated units in the catalogue already meet the requirements of the IEC 60038 standard with a rated voltage of 230 V 6 10 2 4 Wind load For antenna locations safety regulations according to EN 50083 1 differentiate between two heights above ground up to 20 m and above 20 m They specify different dynamic pressure values for each height q 800 N m and q 1100 N m respectively The wind load values horizontal and vertical specified in this catalogue were determined using a dynamic pressure of q 800 N m2 If a value for q 1100 N m2 is needed the v
106. gt 20 gt 20 SAT dB gt 35 Numbers of in output 2 1 2 1 2 1 2 1 DC throughpower FM TV FM TV SAT and 5V Ter Connector F con F con F con F con Weight kg 0 175 0 175 0 200 Dimensions Height mm 117 117 117 Depth mm 50 50 50 Width mm 120 120 120 Remarks 5 V DC Diecast throughpower housing from sat receiver 50 Triax multi band mast combiners Triax TMC range includes a wide range of combiners in blue plastic housing for mast mounting Attractive design in a blue housing Saddle and clamp cable mounting Easy mast or wall mounting O J O e Releasable mast strap for secure fixing TMC Triax Mast Combiner STP Switchable Through Power TMC combiner filter Technical data on TMC multi band mast combiners with saddle and clamp connectors TMC 2831 TMC 4648 TMC 5355 TMC multi band combiners STP STP STP STP 311167 311154 311155 Part No Type Input 1 Band VHF UHF VHF UHF VHF UHF 311153 TMC 3739 group combiner Channel 2 28 2 46 2 53 ch 2 37 ch 39 69 Through loss dB EA ZA d 311154 TMC 4648 group combiner Input 2 Band UHF UHF UHF ch 2 46 ch 48 69 Channel 31 69 48 69 03 69 311155 TMC 5355 group combiner Through loss dB 1 0 1 0 1 0 ch 2 53 ch 55 69 Input 3 Band 311157 TMC 5153 group combiner Channel ch 2 51 ch 53 69 paren asg E 311162 TMC 3537 group combiner Input 4 Band ch 2 35 ch 37 69 Gete ZG dB 311164 TMC 3335 group combiner 9 ch
107. gt 20 db 40 Mhz gt 20 db 40 Mhz gt 15 TV SAT data 5 65 139 862 dB 1 5dB octave 1 5dB octave gt 55 gt 20 Radio out dB gt 12 S12 Radio SAT data dB gt 55 gt 30 Return loss TV EN 50083 4 dB Radio EN 50083 4 dB SAT EN 50083 4 dB Shielding factor VHF UHF dB gt 85 gt 80 gt 85 gt 80 gt 85 gt 80 gt 85 gt 80 gt 85 gt 80 SAT data dB gt 75 gt 75 Connectors TV lIEC male IEC male IEC male IEC male IEC male Radio lIEC female IEC female lIEC female IEC female lIEC female SAT F female F female DC through mA on TV on TV on TV Max 250 100 Max outlets per string 1 3 Impedance Ohm 75 75 75 75 75 Weight kg 0 225 0 225 0 225 0 225 0 225 Dimensions w x h x d mm 66x25x 66 66 x 25 x 66 66 x 25 x 66 66 x 25 x 66 66 x 25 x 66 Remarks Please refer to page 233 for cover frame and terminators 226 ba E dd e BA x UK style outlet housing Triax UK style in SAT TV radio outlets Triax comprehensive series for domestic and system applications r Fully screened Die cast housing DAB compatible Output for SAT and return path DDU outlet designed for installations using Domestic Distribution Unit Technical data on UK style in outlets TYPE Part No incl cover White Outputs TOU Diplexed 2 way 304101 TV Radio TOU DC Diplexed 2 way 304118 TV Radio TOU Triplexed 3 way 304102 TV Radio SAT TOU Quad 4 way 304102 TV Rad
108. link specification dBuV 90 106 CTB 42 ch CENELEC 110 dBuV flat 0 dBm 4 5 OMI dB 68 transmitter spec CSO 42 ch CENELEC 110 dBuV flat 0 dBm 4 5 OMI dB 65 transmitter spec Return loss 40 MHz dB 18 1 5 oct 18 1 5 oct Return path Return path bandwidth depending on diplexer modules MHz 5 65 5 65 Other specifications will depend on the selected transmitter module General Line power voltage VAC 24 65 24 65 Line power current mA 1080 450 800 350 Mains power voltage VAC 175 260 175 260 Power consumption incl return path W 19 0 15 0 Water and dust protection IP 65 65 Internally used optical connector SC APC SC APC Coaxial outputs PG 11 PG 11 Dimensions WxHxD mm 200 x 180 x 82 200 x 180 x 82 Weight kg 2 2 150 Block diagram HTA series of trunk and distribution end amplifiers Line powered or mains powered Medium distribution High output level 108 5 111 dBpV 8 dB tilt Technical data on HTA series Large distribution Very high output level 110 5 113 dBuV 8 cB tilt Standard attenuator pads for gain and tilt adjustment d as well as interstage attenuation and tilt functions HTA 3038 LP1 MP1 amp LA1 MA1 Triax distribution amplifiers HTA 3038 LP2 MP2 amp LA2 MA2 Type Part No HTA 3038 LP1 line powered 322051 HTA 3038 MP1 mains power
109. lt 4 1 lt 3 0 lt 1 8 lt 1 5 470 750 MHz dB lt 52 lt 4 5 lt 3 0 lt 2 3 750 862 MHz dB lt 5 4 lt 4 5 lt 3 0 lt 23 Tap loss output 5 40 MHz dB 8 0 1 0 11 0 1 2 14 0 41 2 17 0 1 2 20 0 1 2 40 470 MHz dB 8 0 1 0 11 0 1 2 14 0 41 2 17 0 1 2 20 0 1 2 470 750 MHz dB 8 0 1 0 11 0 1 5 14 0 1 5 17 0 1 5 20 0 1 5 750 862 MHz dB 8 0 1 0 11 0 1 5 14 0 1 5 17 0 1 5 20 0 1 5 Isolation out tap 5 40 MHz dB gt 19 0 gt 25 0 gt 25 0 gt 30 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 30 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 30 0 750 862 MHz dB gt 25 0 gt 24 0 gt 25 0 gt 30 0 Isolation tap tap 5 40 MHz dB gt 25 0 gt 20 0 gt 25 0 gt 25 0 gt 27 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 27 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 27 0 750 862 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 27 0 Return loss out 5 40 MHz dB gt 19 0 gt 20 0 gt 20 0 gt 18 0 gt 18 0 40 470 MHz dB gt 19 0 gt 20 0 gt 20 0 gt 18 0 gt 20 0 470 750 MHz dB gt 19 0 gt 18 0 gt 18 0 gt 18 0 gt 20 0 750 862 MHz dB gt 19 0 gt 20 0 gt 20 0 gt 16 0 gt 20 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10 A dB gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In
110. module kg 0 45 0 45 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 Remarks Digital measuring DCP Mounted in stand alone cabinet 101 TDH digital terrestrial COFDM to PAL TDH DVB T modules convert a digtal terrestrial coded or uncoded signal to a modulated signal for distribution in a community cable system e Full band high quality modulator e Conditional access via common interface Cl or free to air FTA e Advanced watchdog function Fully DVB T compatible Multi language menu Technical data TDH DVB T modules VSB VHF UHF MPEG transport stream available for slave modules Mono sound A2 stereo Nicam available DVB T master DVB T master TDH DVB T FTA DVB T master DVB T master with Cl with Cl Free to air Free to air A2stereo Nicam A2stereo Nicam Part No B G 490762 490763 590763 490764 490765 590765 D K 490712 490713 490714 490715 Norm L 490712 490714 590715 Pal 490712 490714 Input frequency range MHz 177 5 858 0 177 5 858 0 177 5 858 0 177 5 858 0 Input level EON 44 84 d BA 44 84 d BA Output frequency range Ch 2 69 2 69 2 69 2 69 MHz 47 862 47 862 47 862 47 862 Output level SA modules GEUN 103 103 103 103 Output level attenuator dB 10 10 10 10 Video S N ratio dB gt 54 g
111. outlets is made of dicast aluminium the coax IEC connectors fulfil the DIN 45325 and IEC 169 standards The outlets can be built into a 60 mm round wall box or surface mounted by means of a TOU frame TOU outlet Multimedia Technical data on loop through multimedia outlets Data 5 1000 MHz TYPE TOU 8DL TOU 10M TOU 13M TOU 17M Part No incl cover and frame 1 pcs 302636 302637 302638 302639 excl cover and frame 5 pcs 302686 302687 302688 302689 Outputs TV Radio TV Radio TV Radio TV Radio Data Data Data Data Frequency range TV MHz 125 862 125 862 125 862 125 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 Data MHz 5 1000 5 1000 5 1000 5 1000 Through loss TV dB 3 8 3 0 2 0 1 5 Radio dB 3 8 3 0 2 0 1 5 Data dB 3 8 3 0 2 0 1 5 Tap loss TV dB 8 5 11 5 13 5 17 5 Radio dB 9 5 11 5 14 5 18 0 Data dB 8 5 10 5 13 5 17 5 Isolation Data Radio 5 65 65 862 dB gt 60 gt 25 gt 60 gt 25 gt 60 gt 25 gt 60 gt 25 Data TV 5 65 65 862 dB gt 60 gt 25 gt 60 gt 25 gt 60 gt 25 gt 60 gt 25 Data out dB gt 22 gt 22 gt 22 gt 22 Radio TV dB gt 20 gt 20 gt 20 gt 20 TV out dB gt 25 gt 25 gt 25 gt 25 Radio out dB gt 25 gt 25 gt 25 225 Return loss TV EN 50083 4 dB Cat C Cat C Cat C Cat C Radio EN 50083 4 dB Cat D Cat D Cat D Cat D Data EN 50083 4 dB Cat B Cat B Cat B Cat B Shielding facto
112. output level from the technical data for IMD2 60dB 2nd order intermodulation products acc to EN 50083 5 for IMR3 60dB 3rd order intermodulation products acc to EN 50083 5 e Reduce the IMR3 value according to the number of channels Number of Correction to the channel loads catalog value in dB 2 0 Table1 3 Ze Level reduction as a 4 _3 function of the number 5 SEO of channels loaded 6 5 7 5 5 8 6 10 7 The smaller of the two output levels with respect to IMD2 IMR3 is the permissible output level dB uV for a signal to interference ratio of IMD 60 dB 3 1 2 More than 10 TV channels broadband cable MATV CATV In order to obtain optimal gain from amplifiers with many chan nels loaded it is necessary to use the permissible output levels specifically defined for each such case for a CSO and CTB ratio of 60 dB and a channel raster as close as possible to a defined one 3 1 3 Approximate calculation for the permissible output level a Permissible output level dependent on required CSO and CTB values that are different from catalogue values CSO Question How high is the permissible output level for a CSO value A a dB above the catalogue value CSO 60 dB D output level in dB uV for CSO 60 dB catalogue value N Output level in dB uV for CSO 60 A a dB Nao I Aa i e on an increase in the CSO requirement by A a dB the permissible output level is reduced by A a dB CTB Quest
113. stacking combiners TRIAX has also stacking filters in plast box for combining 2 BIII aerials 2 UHF or 4 UHF aerials ch 21 69 Series 700 stacking combiner Technical data on stacking combiners with PG11 and saddle and clamp connectors Triax stacking combiners 821 UHF 841 UHF 720 Bill 721 UHF 741 UHF 315122 315123 315103 315114 315115 Input 1 Band 2 x UHF 4 x UHF 2 x Bill 2 x UHF 4 x UHF Channel 21 69 21 69 5 12 21 69 21 69 Through loss dB 0 2 0 2 0 3 0 2 0 3 Attenuation 3 0 3 0 6 0 Stacking gain dB 3 0 6 0 2 7 2 8 5 7 Shielding factor dB gt 75 gt 75 gt gt gt Numbers of in output 2 1 4 1 2 1 2 1 2 1 DC throughpower Yes Yes Yes Yes Yes Connector PG11 PG11 S amp C S amp C S amp C Weight kg 1 1 1 1 0 2 0 2 0 2 Dimensions Height mm 146 146 90 90 90 Depth mm 80 80 48 48 48 Width mm 194 194 115 115 115 Remarks PG11 adaptor for connection of 7 mm cable Part No 342601 59 Mast calculation The conditions detailed in the EN 50083 1 must be ob served when mounting antennas on a mast The sum of the moments resulting from the intrinsic mo The distance and bending moment refer to the top clamping point Bending moments in excess of 1650 Nm require proof of structural stability ment of the mast and the bending moments caused by the mounted antennas must not exceed the maximum Wind load x distance bending moment permitted bending moments of the mast itself
114. the TD series dishes more detailed information on page 91 under LNB brackets TD multi block Ral 7016 Ral 7030 d AO Triax TDA Euroline series aluminium dishes A dish for any job TD dishes are available in sizes materials and colours for any job ranging from single to multiple use applications and any type of environment e 5 sizes ranging from 50 x 55 cm 34 2 dBi gain to 100 x 105 cm 40 2 dBi gain e Delivered in aluminium or galvanized steel e Available in a number of standard colours and any other colour and own label branding can be supplied against a minimum quantity e Available in DeLuxe version with anti corrosive coating also on the feedarm and the elevation and mast bracket e Delivered in individual packaging but also available in bulk packs minimizing costs of transportation and handling TD dishes are of course manufactured according to Triax s quality standards with precision tools and robots ensuring absolute uniform and optimum geometry for perfect signal reception Technical data on TDA Euroline aluminium dishes TDA 54 TDA 64 TDA 78 TDA 88 TDA 110 50 x 56 cm 60 x 65 cm 70 x 78cm 85 x 95 cm 100 x 105 cm Part No Light grey Ral 7035 123560 123660 123760 123860 123960 Grey Ral 7030 Anthracite Ral 7016 123661 123761 123861 123961 Red Ral 8012 123662 123762 123862 123962 Frequency range GHz 10 7 12 75 10 7 12 75
115. x 190 x 45 120 x 190 x 45120 x 190 x 45 113 TCH TCSA analogue satellite modules Plug in analogue satellite modules for TCH 600 headend DSB UHF DSB VHF Technical data TCSA analogue satellite modules DSB VHF S and UHF TYPE TCSA 611 TCSA 613 TCSA621 TCSA612 TCSA 614 TCSA 622 analogue analogue analogue analogue analogue analogue Part No 490611 490613 490648 490612 490614 490649 Modulator type DSB DSB DSB DSB DSB DSB Band VHF S VHF S VHF S UHF UHF UHF TV standard system B G L D K B G I L D K B G Il L D K B G I L D K B G l L D K B G L D K Input frequency range MHz 920 2150 920 2150 920 2150 920 2150 920 2150 920 2150 Input level dBm 65 25 65 25 65 25 65 25 65 25 65 25 IF bandwidth programmable MHz 18 27 18 27 27 32 18 27 18 27 27 32 Output frequency range Ch E5 E12 E5 E12 E5 E12 21 69 21 69 21 69 11 S25 11 525 11 525 Output level dBuvV 90 100 90 100 90 100 90 100 90 100 90 100 Output level attenuator dB 0 10 0 10 0 10 0 10 0 10 0 10 Video S N ratio dB gt 54 gt 54 gt 54 gt 48 gt 48 gt 48 Spurious signals ref dB gt 60 gt 60 gt 60 gt 60 gt 60 gt 60 picture carrier Sound mode Mono A2 stereo Mono Mono A2 stereo Mono Audio frequencies MHz 5 50 9 77 5 50 9 77 5 50 9 77 5 50 9 77 5 50 9 77 5 50 9 77 LNB control Volt 14 18 1
116. 0 1750 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 12 0 gt 12 0 1750 2150 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 12 0 gt 12 0 2150 2400 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 12 0 gt 12 0 Return loss in 5 40 MHz dB gt 25 0 gt 30 0 gt 30 0 gt 40 0 gt 25 0 gt 30 0 40 1000 MHz dB gt 22 0 gt 20 0 gt 20 0 gt 20 0 gt 22 0 gt 20 0 1000 1750 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1750 2150 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 2150 2400 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 Return loss out 5 40 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 40 1000 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1000 1750 MHz dB gt 17 0 gt 17 0 gt 17 0 gt 17 0 gt 17 0 gt 17 0 1750 2150 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 2150 2400 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 gt 15 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass In Out In Out In Out In Out In Out In Out Connectors F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg 0 137 0 137 0 137 0 137 0 137 0 137 Dimensions h x d x w mm 60x16x117 60x16x117 60x16x117 60x16x117 60x16x117 60x 16x 1
117. 0 Hum modulation 10 A dB gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In out In out In out In out In out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector Certification CE CE CE CE CE Impedance Ohm 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 e Fix TLD bracket for wall mounting of splitters Part No 80262 189 Triax taps TLT series outdoor Outdoor trunk taps with frequency ranges from 5 to 1000 MHz All ports impedance 75 Ohm In out current passing 10 A 60 VAC The 100 dB RFI integrity is maintained by the use of tongue and groove design and with a stainless steel mesh RFI gasket Continual power through between input and output Aluminum alloy housing is finished with a baked acrylic paint to protect from elements Neoprene sealed and nickel plated brass for all 5 8 port entry and taps F f port Provides uninterrupted power and RF service when the faceplate is removed Technical data TLT series of 5 1000 MHz outdoor 4 taps TLT 408 TLT 411 TLT 414 TLT 417 TLT 420 80249 80231 80235 80232 80233 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 Outputs pcs 4 4 4 4 4 Insertion loss 5 40 MHz dB lt 3 5 lt 2 5 lt 1 2 lt 1 0 40 470 MHz dB
118. 0 Weight kg 0 220 0 220 0 220 0 220 Remarks Hi end DiSEqC Hi end DiSEqC Hi end DiSEqC Hi end DiSEqC switch switch switch switch e e Si ESE SEE GEA eari HN 93 DiSEqC switches multi satellite reception DiSEqC switch A DiSEqC switch is applied when using 2 universal LNBs In principle a DiSEqC switch works as a tone switch but if you connect a universal LNB 22 kHz tone is used for switching between 9 75 and 10 6 MHz Priority switch This switch connects two satellite receivers with one or more LNBs It may be a system with an analog and a digital receiver or a Pal and a Mac receiver The switch has two i outputs the A output having priority If the receiver connected to the output having DiSEqC 2x1 Pos 300502 priority is switched off the other receiver will control the LNBs Both receivers can use the same LNB at the same time provided that the channels transmit with the same polarisation and in the same band NB The receiver having priority is in control MATRIX switch The MATRIX switch is working according to the same principle as a DiSEqC switch The MATRIX switch has 4 inputs which makes it possible to control up to 4 universal LNBs via a single coaxial cable Technical data on DiSEqC switches DiSEqC 502 Priority 503 DiSEqC 504 Priority 506 Hi Iso 2x1 1x2 4x1 2x1 300502 300503 300504 300506 Number of inputs 2 1 4 2 outputs 1
119. 0 gt 24 0 gt 25 0 gt 25 0 470 750 MHz dB gt 24 0 gt 24 0 gt 25 0 gt 25 0 gt 25 0 750 862 MHz dB gt 23 0 gt 23 0 gt 25 0 gt 24 0 gt 24 0 Return loss out 5 40 MHz dB gt 15 0 gt 15 0 gt 16 0 gt 18 0 gt 17 0 gt 17 0 40 470 MHz dB gt 17 0 gt 17 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 470 750 MHz dB gt 17 0 gt 17 0 gt 18 0 gt 16 0 gt 18 0 gt 18 0 750 862 MHz dB gt 17 0 gt 17 0 gt 17 0 gt 16 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10 A dB gt 66 gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In out In out In out In out In out In out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector F connector Certification CE CE Ce CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 188 e Fix TLD bracket for wall mounting of splitters Part No 80262 d 1 Let 17B Triax taps TLT series outdoor TLT 223 TLT 226 TLT 229 TLT 232 TLT 235 80244 80245 80246 80247 80248 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 Outputs pcs 2 2 2 2 2 Insertion loss 5 40 MHz dB lt 0 8 lt 0 8 lt
120. 0 0 gt 20 0 gt 20 0 gt 20 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Return loss tap 5 40 MHz dB gt 18 0 gt 18 0 gt 19 0 gt 22 0 gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 22 0 gt 22 0 gt 22 0 470 750 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 20 0 gt 20 0 gt 20 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No No Connectors F connector F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE Ce CE Impedance Ohm 75 75 75 75 75 75 75 Weight kg 0 070 0 070 0 070 0 070 0 070 0 070 0 070 Dimensions h x d x w mm 38x16x74 38x16x74 38x16x74 38x16x74 38x16x74 38x16x74 38x16x74 169 Triax taps ATT series 5 1000 MHz CLASS GRADE 1 ATT 2 8 ATT 2 10 ATT 2 12 ATT 2 16 ATT 2 20 ATT 2 24 346208 346210 346212 346216 346220 346224 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 2 2 2 2 2 2 Insertion loss in out 5 40 MHz dB lt 3 6
121. 0 1510 30 50 70 20 20 3 3 Output power mW 0 5 1 0 2 0 2 0 RIN dB Hz 125 130 145 140 IM2 Measured at 10 OMI dBc 40 40 44 45 IM3 Measured at 10 OMI dBc 50 50 57 55 ay OMI 5 db loss W 600 kHz dBc 35 38 52 52 CNR 10 OMI 5 db loss BW 2 MHz dBc 42 45 59 59 Input level for 10 OMI dBuvV 74 72 74 77 Flatness dB 0 5 0 5 0 5 0 5 Attenuation by pads on motherboard dB 0 18 0 18 0 18 0 18 General Power consumption W 0 2 max 0 5 0 2 max 0 5 0 2 max 0 5 0 2 max 0 5 Temperature range for the node C 20 to 55 20 to 55 20 to 55 20 to 55 Internally used connector SC APC SC APC SC APC SC APC Technical data on MCA automatic gain control modules TYPE MCA 100 MCA 100 MCA 100 423 MHz 519 MHz 639 MHz Part No 322240 322242 322244 Return path AGC attenuation range dB 4 4 4 AGC accuracy dB 0 5 0 5 0 5 Pilot frequency factory adjusted MHz 400 to 750 400 to 750 400 to 750 Nominal output level range GEUN 100 110 100 110 100 110 Power consumption W 1 5 1 5 1 5 Dimensions WxHxD mm 112 x 70 x 38 112 x 70 x 38 112 x 70 x 38 154 Triax Accessories for amplifiers Pads Part No Attenuation Tilt Supplied in bags OEI OEI of 10 pcs JXP OT200 322200 0 0 Tall orange JXP OT201 322201 1 1 Tall orange JXP OT202 322202 2 2 Tall orange JXP OT203 3
122. 0 18 amp 22 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Linearity dB 1 3rd order DIN 45004 B GEUN 124 127 2nd order DIN 45004 A1 dBuV 122 124 CTB 42 ch CENELEC flat 8 dB tilt GEUN 108 5 111 110 5 113 CTB 42 ch CENELEC by 6 GB interstage att flat 8 dB tilt dBuV 108 110 110 112 CSO 42 ch CENELEC GEUN 112 114 Noise figure 47 862 MHz dB 5 6 5 5 6 5 5 6 5 5 6 5 Noise figure by 6 dB interstage attenuation 47 862 MHz dB 6 8 5 7 6 8 5 7 Return loss 40 MHz dB 18 1 5 oct 18 1 5 oct Return path Return path bandwidth depending on diplexer modules MHz 5 65 5 65 Gain dB 23 23 Attenuation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 8 0 8 Linearity dB 1 1 3rd order DIN 45004B dBuV 119 119 2nd order DIN 45004A1 dBuV 104 104 Noise figure dB 6 6 General Line power voltage VAC 24 65 24 65 Line power current mA 750 330 870 380 Mains power voltage VAC 175 260 175 260 Power consumption incl return path W 13 5 16 0 Dimensions WxHxD mm 200 x 180 x 82 200 x 180 x 82 Weight kg 2 2 152 Type Part No e Large distribution HEA series of distribution end amplifiers e Line powered or mains powered e Medium distribution High output level 108 5 111 dBuv 8 dB tilt Very high output level 110 5 113 dBu
123. 0 377 0 377 0 377 Dimensions H x D x W mm 120 x 190 x 45 120 x 190 x 45 120 x 190 x 45 112 TCH TCMA modulator modules Plug in modulator modules for TCH 600 headend VSB modulator A 2 ra Technical data TCMA modulator modules VSB VHF UHF TYPE TCMA 615 TCMA 617 TCMA 616 TCMA 618 TCMA 673 TCMA 674 modulator modulator modulator modulator modulator modulator Part No 490615 490617 490616 490618 490673 490674 Modulator type DSB DSB DSB DSB VSB VSB Band VHF S VHF S UHF UHF VHF UHF VHF UHF TV standard system B G I L D K B G I L D K B G I L D K B G I L D K B G I L D K B G I L D K Output channel E5 E12 E5 E12 21 69 21 69 2 69 2 69 511 925 11 525 Output level dBuvV 90 100 90 100 90 100 90 100 90 100 90 100 Output level attenuator dB 0 10 0 10 0 10 0 10 0 10 0 10 Video S N ratio dB gt 54 gt 54 gt 54 gt 54 gt 54 gt 54 Sound mode Mono A2 stereo Mono A2 stereo Mono A2 stereo Video input CVBS level Vpp 0 7 1 3 0 7 1 3 0 7 1 3 0 7 1 3 0 7 1 3 0 7 1 3 Audio input level V RMS 0 5 0 5 0 5 0 5 0 5 0 5 Input connector 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D Impedance Ohm 75 75 75 75 75 75 Operation temperature range C 0 50 0 50 0 50 0 50 0 50 0 50 Weight kg 0 232 0 232 0 232 0 232 0 350 0 350 Dimensions H x D x W mm 75x190 x45 75x190 x45 75x190 x45 75
124. 0 700 1000 Height mm 210 210 210 210 210 Weight kg Packing QTY pcs 1 1 1 1 1 Remarks for 2 x BB grid Technical data on mounting pipes Pipe Pipe Pipe MF 38 SR 2530 2B 140116 140117 140118 Mast diameter mm 30 50 30 50 30 50 Diameter on bracket mm Material Galv steel Galv steel Galv steel Length mm Height mm Weight kg Packing QTY pcs 1 1 1 Remarks for mounting aerials vertical 67 Mounting clamps Technical data on accessories Type Clamp Clamp U clamp Mast clamp Double mast with bolts clamp Part No 133107 133100 140035 140041 133245 Mast diameter mm 30 50 30 50 30 50 Material Steel Steel Steel Surface tratment mm Galv Galv Electro galv Electro galv Galv Weight kg Packing QTY pcs 1 1 2 1 Remarks Fits all types of Galv U clamps mounting brackets for wall mounts Technical data on accessories Type Mast brac Jaw bracket Kip bracket Phone mast straight Universal 34 cm bracket Part No 140041 130010 132020 130020 Mast diameter mm 38 30 50 30 50 38 50 Material Galv steel Steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 Remarks with 2 Tilt mast bracket screws aerials beam Ke Technical data on accessories Type G bolt G bolt G bolt G bolt 1 2 Disc 1 2 Nuts 1 2 1 2 1 2 1 2 for G bolt for G bolt Part No 133090 133100 133101 133102 133086 850035 Diameter mm 12 12 1
125. 0 O 12 10 0 12 Lenght mm 1000 1000 1000 2375 5500 Material Galvanized Galvanized Galvanized Aluminium Aluminium steel steel steel Weight kg Packing QTY pcs 25 25 25 5 5 Remarks Cable guard for Cable guard for 7 mm cable 7 mm cable Technical data on cable duct Type Cable duct Cable duct White plast White plast Part No 153090 153092 Size Width mm 16 25 Height mm 16 16 Material White White plastic plastic Weight kg Packing QTY m roll 15 15 Remarks 72 Clips screws and expansion bolts Technical data on cable clips natural Cable clips Cable clips Cable clips Cable clips Cable clips Cable clips Natural Natural Natural Natural Natural Natural 153013 153001 153003 153004 153008 153010 Size Diameter mm 2x4 3x5 5 20 6 25 7 25 7 35 Lenght mm 20 20 20 25 25 35 Material Plastic Plastic Plastic Plastic Plastic Plastic Weight kg Packing QTY per box pcs 100 100 100 100 100 100 Remarks Cartons of Cartonsof Cartonsof Cartonsof Cartonsof Cartons of 10 boxes 10 boxes 10 boxes 10 boxes 10 boxes 10 boxes AGZ EZ Technical data on cable clips black and expansion bolts Cable clips Cable clips Cable clips Cable clips Cable clips Expansion Expansion Black Black Black Black Black bolts bolts 153080 153081 153082 153083 153084 140380 140370 Size Diameter mm FC 7 9 FC 9 11 FC 11 13 FC 13 15 FC 15 17 10 8 Lenght mm 20 25 25 30 35 80 100 Material Plastic Plastic Plastic
126. 0 pcs pll 32 123846 TDA 88 Bulk Ral 7016 100 pcs pll TRIAX Basic dishes Complete range in Basic dishes carefully designed to give the best value in price and quality The mechanical parts of the Basic dishes have been created with careful attention to detail and recommendations from installers The dishes are manufactured using a fine anti corrosive treatment e Improved maintenance free reception e Polyester powder coated e Computer aided design for high performance e Easy to install e 50 cm 60 cm 75 cm and 85 cm size options e Pole mount e Easy adjust elevation scale e 100 pcs bulk pack Ral 7035 Technical data on Basic dishes Basic 60 Basic 60 Basic 75 Basic 85 w south bracket 60 x 65 cm 60 x 65 cm 70 x 78 cm 85 x 95 cm Part No light grey Ral 7035 128601 128602 128701 128801 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 35 8 35 8 37 1 38 8 G T LNB 0 7 dB dB K 16 0 16 0 17 3 19 2 X polarisation dB gt 2 gt 2 gt 2 gt 27 Offset angle degrees 26 26 26 26 Elevation range degrees 10 50 10 50 10 60 10 60 45 80 45 80 Reflector type F D 0 6 Offset Offset Offset Offset Beam width degrees 3 1 3 1 2 6 2 0 Windload 42 m s N 445 445 619 902 Material Galv steel Galv steel Galv steel Galv steel Finish Polyester powder Polyester powder P
127. 00 5 1000 5 1000 5 1000 5 1000 Outputs pcs 2 3 4 6 8 12 16 Insertion loss in out 5 40 MHz dB lt 3 2 lt 5 7 lt 6 7 lt 9 7 lt 10 2 12 0 13 2 40 470 MHz dB lt 3 5 lt 5 8 lt 6 7 lt 10 2 lt 10 2 13 0 13 2 470 860 MHz dB lt 3 7 lt 6 2 lt 7 9 lt 10 7 lt 12 2 13 5 14 2 Isolation 5 40 MHz dB gt 28 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 30 gt 30 40 470 MHz dB gt 28 0 gt 25 0 gt 28 0 gt 25 0 gt 25 0 gt 30 gt 30 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 30 gt 30 Return loss in 5 40 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 40 470 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 470 860 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 Return loss out 5 40 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 40 470 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 470 860 MHz dB gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 12 0 gt 18 gt 18 Shielding efficiency VHF UHF dB 2110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No No Connectors F connector F connector F connector F connector F connector F F Certification CE CE CE CE CE W CE Impedance Ohm 75 75 75 75 75 75 75 Weight kg 0 046 0 063 0 069 0 130 0 137 6 595 0 615 Dimensions h x d x w mm 50x16x52 50x16x74 50x16x74 60x 16x1
128. 03x51x145 103x51x255 103x51x255 103x51x355 103x51 x455 a q de EEE GO a dd m TMS 5x8 Ln 134 TMS 5X16 Triax TMS 5xP multiswitches Fulfilling subscriber needs the most efficient way The TMS 5x series of our multiswitch systems offers unique subscriber benefits in terms of performance and individual freedom Advanced technology is used to provide these benefits but is applied in a logical modular way helping the peer d b professional installer save time pan el 2 a tl Sa zer d da y eee e Ge wT d da agen aa d i SE E TMS 5x4p ai bei ear GE i z a a tt vi A y wu TMS 5x6p TMS 5X8p Technical data Single multiswitches with 4 polarities 1 terr input With power supply TYPE TMS 5x4P TMS 5x6P TMS 5x8P TMS 5x12P TMS 5x16P Part No EU plug 300324 300326 300328 300322 300327 Part No UK plug 300334 300336 300338 300332 300337 Number of inputs 4 SAT 1 TER 4SAT 1 TER 4SAT 1 TER 4SAT 1TER 4SAT 1TER Subscriber outputs 4 6 8 12 16 Connectors F con female female female female female Frequency range SAT MHz 950 2150 950 2150 950 2150 950 2150 950 2150 Frequency range TER MHz 47 862 47 862 47 862 47 862 47 862 Gain SAT dB 6 5 5 5 3 Gain TER dB 4 3 3 0 4 Isolation TER to SAT dB 22 25 25 22 22 Isolation SAT to TER dB
129. 08 108 108 Depth mm 50 50 50 50 50 50 Width mm 120 120 120 120 120 120 Remarks FM notch FM notch FM notch TV 2 input with BI BII UHF 2 attenuators 35 Triax MFA mast amplifier series High performance range of mast amplifiers with F connector Low noise figures FM notch version High output level F connectors on all in and outputs Simple and easy installation Releasable mast strap Attractive design in a 4 terminal waterproof masthousing Wide range with 1 2 or 3 inputs and 1 output High gain and output voltage Fixed or adjustable gain RF shielded and CE compliant EN 50083 MFA Mast F connector Amplifiers Unique power stabiliser enables use of any power unit from 12 V to 24 V Technical data on MFA mast amplifiers with F connectors MFA 322 MFA 323 MFA 324 MFA 325 MFA 327 MFA 331 340322 340323 340324 340325 340327 340331 Input 1 Ch 36 69 Channel Band UHF UHF UHF UHF VHF UHF BI Gain dB 15 12 25 25 25 12 22 Input 2 Channel Band FM Gain dB 12 22 Input 3 Channel Band BIII Gain dB 12 22 Input 4 Channel Band UHF Gain dB 12 22 Noise figure UHF dB 1 8 1 8 1 8 2 2 1 8 3 5 VHF dB 2 2 4 0 Max output voltage 60 dB IMA dBuV 4x85 105 105 105 105 105 Numbers of in output 1 4 1 1 1 1 1 1 1 1 4 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 30 30 30 25 40 25 DC throughpower Connector F con F con F con F con F con F con Weight kg 0 230 0
130. 08 A1 FM See 171 300102 _CM01 Type UHF 117 324280 ACB 280 Sat IF amplifier 128 346320 ATT 3 20 171 yp 300116 CM 01 Type UHF amplifier 117 322230 Accessory Box 155 346412 ATT 4 12 172 300101 CM 01 Type VHF 117 251513 Additional frame for TMF 512 124 GES ATT 4 16 102 oe OF ere be 251514 Additional frame for TMF 512 1 2 size 124 346420 ATT 4 20 172 490898 CMO02V VHF Modulator 116 104579 Aerial 10el ch 5 12 12 346512 ATT 5 12 172 123051 Cox coUodd EEE 100582 Aerial 13el ch 5 11 12 346616 ATT 6 16 172 ping grey 153055 Coax coupling white 212 100016 Aerial 2el ch 4 9 B 100022 Aerial 2el_ch_2 foldable reflect 3 153043 Coax Female angle 211 Se rel E e Eor 300724 Basic 3dg DuoBlock Black 88 153022 Coax Female Angle diecast housing 211 100032 Aerial 2el ch 3 foldable reflector 8 400015 Aerial3el chA E Ee 300722 Basic 6dg DuoBlock Black 88 153035 Coax Female angle Grey 211 bezeria SO Cara ar ee e 300723 Basic FlexiBlock Black 88 150180 Coax KOKA 100 200 ines AGA Re Ze EE 75 128601 Basic 60 Bulk Ral 7035 83 _ 150181 Coax KOKA 100 200 103861 Aerial 4 h AA rer 19 128602 Basic 60 Bulk Ral 7035 with south bracket 83 150182 Coax KOKA 100 200 tea a geio de 128701 Basic 75 Bulk Ral 7035 83 _ 150193 Coax KOKA 100 200 bagez Ga GG b i erica e 128801 Basic 85 Bulk Ral 7035 83 150186 Coax KOKA 100 black 204 ena 8 6 300729 Basic multiblock for 4xLNB without LNB amp switch 88 150187 Coax KOKA 100 black 204 104665 Aerial Gel ch
131. 0m 18 6 28 4 2050 MHz dB 100m 20 5 30 7 2400 MHz dB 100m 22 1 33 2 Structural Return Loss SRL 5 470 MHz dB gt 30 0 gt 30 0 470 862 MHz dB gt 25 0 gt 25 0 862 2400 MHz dB gt 20 0 gt 20 0 Approval EN 50117 CEl 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes Burial Yes black Yes 205 Triax multi cable for outdoor use Multi cables for networks Triple shielded RG 6 multi cables where individual cable colours can be used through the whole system to facilitate proper connection Technical data on triple shielded outdoor multi cable 18 multi 4 cable 18 multi 9 cable Triple shielded Triple shielded Black White PE PVC Part No Wood drum 50 m 150078 Wood drum 100 m 150074 150079 Wood drum 250 m Wood drum 500 m Center conductor mm 1 02 1 02 Center conductor material Cu blank Cu blank Isolation mm 4 6 4 6 Dielectric PEE foamed PEE foamed Screen Al PET AI Al PET AI um Braid material CuSn CuSn construction Omm coverage 40 0 40 0 Screening attenuation dB Anti migration foil um Outer sheath PE PE Minimum bending radius mm 100 100 Diameter mm 19 0 25 0 Application Outdoor Outdoor ELECTRICAL DATA Impedance Ohm 75 75 Capacitance pF m 52 52 Velocity ratio 84 84 Center conductor dc resistance Ohm km 22 22 Outer conductor dc resistance Ohm km 26 26
132. 1 331456 SCF 56 15A3 comb K56 57 348216 STT 2 16 183 303460 TD 260D 221 331457 SCF 57 15A3 comb K57 57 348220 STT 2 20 183 302511 TD 263D 221 331458 SCF 58 15A3 comb K58 57 348412 STT 4 12 184 303511 TD 263D 221 331459 SCF 59 15A3 comb K59 57 348416 STT 4 16 184 302461 TD 263D 221 331460 SCF 60 15A3 comb K60 57 348420 STT 4 20 184 303461 TD 263D 221 331462 SCF 62 15A3 comb K62 57 348424 STT 4 24 184 302422 TD272D 223 331463 SCF 63 15A3 comb K63 57 348430 STT 4 30 184 303422 TD272D 223 331464 SCF 64 15A3 comb KOA 57 348616 STT 6 16 185 302428 TD 278 D 223 331465 SCF 65 15A3 comb K65 57 348620 STT 6 20 185 303428 TD 278 D 223 331466 SCF 66 15A3 comb K66 57 348624 STT 6 24 185 302430 TD 280 DAB 221 317403 SCF XX 15 A2 55 348816 STT 8 16 185 303430 TD 280 DAB 221 317405 SCF XX 15 A4 55 348820 STT 8 20 185 302131 TD 301 226 737040 Screw set for electronics 10 pcs 124 T 303131 TD 301 226 140360 Screw 10 x50 mm bag with 100 pcs 73 333430 TA13A 40 302134 TD 304 226 140361 Screw 10x 80 mm bag with 100 pcs 73 333433 TA 13 B 40 303134 TD 304 226 140380 Screw 10x 80 mm bag with 50 pcs 73 333436 TA 13 C D 40 302132 TD 312 226 140340 Screw 6 x 50 mm bag with 200 pcs 73 333439 TA13E 40 303132 TD 312 226 140350 Screw 8 x 50 mm bag with 200 pcs 73 333400 TA 13W 40 302152 TD 352 226 140351 Screw 8 x 80 mm bag with 200 pcs 73 T 303152 TD 352 226 255 Contents from A to Z
133. 1 0 0 125 18 8 0 0 112 41 4 00 Tz 140 103 0 95 0 5 1 06 0 11 19 8 9 0 125 42 4 50 73 160 104 0 89 1 0 1 12 0 10 20 10 0 0 140 43 5 00 14 180 105 0 84 1 5 1 19 0 089 21 10 0 0 160 44 5 60 15 200 106 0 8 2 0 1 25 0 08 22 12 5 0 180 45 6 30 76 229 107 0 75 2 5 1 33 0 071 23 14 1 0 200 46 7 00 DO 250 108 0 71 3 0 1 41 0 063 24 16 0 0 225 47 8 00 18 280 109 0 67 3 5 1 5 0 056 25 17 8 0 250 48 9 00 19 315 110 0 63 4 0 1 6 0 050 26 20 0 0 280 49 10 0 80 355 111 0 60 4 5 1 67 0 045 27 22 4 0 315 50 11 2 81 400 112 0 56 5 0 1 78 0 04 28 25 0 0 355 51 12 5 82 450 113 0 53 5 5 1 88 0 035 29 28 2 0 400 52 14 0 83 900 114 0 50 6 0 2 0 0 032 30 31 6 0 450 53 16 0 84 960 115 0 47 6 5 2 12 0 028 31 35 5 0 500 54 18 0 85 630 116 0 45 7 0 2 24 0 025 32 40 0 560 55 20 0 86 700 117 0 42 7 9 2 37 0 022 33 45 0 630 56 22 9 87 800 118 0 4 8 0 2 5 0 020 34 50 0 700 57 25 0 88 900 119 0 38 8 5 2 66 0 018 35 56 0 800 58 28 0 89 1000 120 0 35 9 0 2 82 0 016 36 63 0 900 59 31 5 90 1120 121 0 33 9 5 3 00 0 014 37 71 1 00 60 35 5 91 1250 122 0 32 10 3 16 0 0125 38 80 1 12 61 40 0 92 1400 123 0 28 11 3 55 0 011 39 89 1 25 62 45 0 93 1600 124 0 25 12 4 00 0 01 40 100 1 40 63 90 0 94 1800 125 0 22 13 4 5 0 0056 45 178 1 60 64 96 0 95 2000 126 0 2 14 5 00 0 0032 50 316 1 80 65 63 0 96 2250 127 0 18 15 5 62 0 0018 55 562 2 00 66 70 0 97 2500 128 0 16 16 6 3 0 001 60 1000 225 67 80 0 98 2800 129 0 14 17 7 1 e E 2 50 68 90 0 99 2 80 69 100 100 The numbers are dB value calculate
134. 1 2 1 2 1 DC throughpower SAT SAT Switchable UHF Both inputs VHF UHF both inputs Connector F con F con F con F con F con F con Weight kg 0 175 0 175 0 175 0 175 0 175 0 175 Dimensions Height mm 117 117 117 117 117 117 Depth mm 50 50 50 50 50 50 Width mm 120 120 120 120 120 120 Remarks 49 Triax MFC multi band mast combiners Triax MFC range of mast combiners with F connector Improved attractive housing Releasable mast strap Mast or wall mounting F connector Wide range with 2 or 3 inputs and 1 output Switchable DC through power RF shielded and CE marked EN 50083 MFC Mast F connector Combiner Example MFC 151 features e 2 inputs VHF UHF and SAT e 5 V power feed for active antenna or pre amplifier DC power pass for LNB supply Fully shielded F connectors MFC combiner filter Waterproof housing Easy mounting on mast or wall Technical data on MFC mast combiners with F connectors MFC 120 MFC 121 MFC 151 TV SAT Diecast 340120 340121 340151 340110 Input 1 Band FM TV FM TV SAT SAT Channel 2 9 21 69 2 10 21 69 IF IF Through loss dB 1 5 15 2 0 Input 2 Band DAB DAB VHF UHF VHF UHF Channel 11 13 12 13 2 69 2 69 Through loss dB 1 5 1 5 1 0 1 0 Input 3 Band Channel Through loss dB Input 4 Band Channel Through loss dB Stop band attenuation VHF BI dB gt 20 gt 20 gt 20 FM dB gt 20 gt 20 gt 20 BIDAR dB gt 20 gt 20 gt 20 UHF dB gt 20
135. 1 25 negative FM L F 625 8 6 6 5 1 25 positive AM M FCC 525 6 4 2 4 5 0 75 negative FM N South America 625 6 4 2 4 5 0 75 negative FM Second audio carrier for dual or stereo operation 247 Technical appendix 6 Frequency ranges and channel allocation Channel Frequency Picture carrier ist Channel Frequency Picture carrier ist MHz wave MHz MHz sound MHz wave MHz MHz sound Return data Band 21 470 478 471 25 476 75 communication 4 to 30 F IV 22 478 486 476 25 484 75 Return TV EE 14 75 21 75 23 486 494 487 25 492 75 R2 21 75 28 75 24 494 502 495 25 500 75 Band 2 47 to 54 48 25 53 75 25 502 510 503 25 508 75 3 54 to 61 55 25 60 75 26 510 518 511 25 516 75 4 61 to 68 62 25 67 75 27 518 526 519 25 524 75 Data channel 70 to 75 28 526 534 527 25 532 75 29 534 542 535 25 540 75 eN Sa 30 542 550 543 25 548 75 Band II 2 70 87 5 108 31 550 558 551 25 556 75 Digital sound S2 111 118 39 558 566 559 25 564 75 1st channel s3 118 125 33 566 574 567 25 572 75 Lower S4 125 132 126 25 131 75 34 0 4 582 979 25 980 75 S channels S5 132 139 133 2
136. 1 TDS 88 Single EUROLINE Ral 7016 80 o dae ezke a A a 490762 TDH 762 Master DVB T mono module CI 102 121860 TDS 88 Single EUROLINE Ral 7035 80 Gadea aA Sa Sa EE Sa 490763 TDH 763 Master DVB T stereo module Cl 102 121862 TDS 88 Single EUROLINE Ral 8012 80 Eo a EAE ee E 490764 TDH 764 Master DVB T mono module FTA 102 122812 TDS 88 Single packed Ral 7016 78 Begiei Sa Gare Sg 490765 TDH 765 Master DVB T stereo module FTA 102 122810 TDS 88 Single packed Ral 7030 78 009 UOP OCX Arey 490766 TDH 766 AV VSB modulator mono PAL I Secam 108 122818 TDS 88 Single packed Ral 7035 78 123961 TDA 110 Single EUROLINE Ral 7016 81 123960 TDA 110 Sinole EUROLINE Ral 7035 81 490767 TDH 767 AV VSB modulator stereo PAL I Secam 108 302045 TD surface mount 50x50 233 a geie T Ga b 490775 TDH 775 TV Ch converter analogue 106 303045 TD surface mount 50x50 233 E Ga Gra ee Ge a 490776 TDH 776 TV Ch Converter analogue 106 302046 TD surface mount 50x77 233 A ACL ng e Ge e E a Ge E 490778 TDH 778 TV Ch Converter digital 106 303046 TD surface mount 50x77 233 ee EE ene Gida er beg 490779 TDH 779 FM Ch Converter analogue 105 708028 Termostat 123 ave eer Zerga ge bee 300765 TDH Access GSM 109 334220 TFS 220 DAB TV FM 194 EEE EE EEE E 300766 TDH Access N port box for internet 109 334221 TFS 221 DAB TV FM 194 aie dE 300764 TDH Access standard phone modem 109 334202 TFS 715 2 194 123648 TDA 64 Bulk Ral 7035 100 pcs pll 82 123647 TDA 64 Bulk Ral 8012 100
137. 10 230 10 Power consumption W 4 5 6 7 9 Operating temperature C 25 55 25 55 25 55 Protection class Il Il lI Degree of protection IP 20 20 20 Dimensions WxHxD mm 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50 Weight kg 0 64 0 64 0 68 Packing unit 1 pcs carton box 1 pcs carton box 1 pcs carton box Reference standards Product standards safety EMC ROHS 2002 95 EG compliant EN 50083 3 Class 2 EN 50083 1 EN 60065 EN 50083 2 160 IFE amplifiers for SMATV applications Triax distribution amplifiers e Excellent electrical performance for low cost and low power consumption e Simple initiation because of reduced controller elements e Q types apartment amplifiers with 4 outputs for simple home installations IFE amplifier housing Technical data on IFE series Type Part No IFE 20 323022 IFE 30 323025 IFE 12 QM 323028 IFE 16 Q 323031 Frequency range MHz 40 862 40 862 5 65 85 862 40 862 Basic unit without RP modules MHz 1000 MHz 1000 MHz 1000 MHz selected VHF on RP off MHz selected VHF off RP on MHz Gain forward Gain 862 MHz out 1 dB 21 29 12 16 Gain 862 MHz out 2 3 4 dB 10 5 17 Attenuator at input dB 0 20 0 20 0 20 0 20 Gain return path Gain 60 MHz dB 1 0 Attenuator elements at input dB Attenuator elements at output dB Amplitude response for
138. 115 115 Max input level dBuvV 100 100 100 Numbers of in output 1 1 1 1 1 1 1 1 1 1 1 1 Voltage VDC 24 24 24 24 24 24 Power mA 30 30 30 30 30 30 DC throughpower No No No No No No Connector PG 11 PG 11 PG 11 PG 11 PG 11 PG 11 Weight kg 1 322 1 322 1 322 1 322 1 322 1 322 Dimensions Height mm 146 146 146 146 146 146 Depth mm 80 80 80 80 80 80 Width mm 194 194 194 194 194 194 Remarks Low noise Low noise Low noise Low noise Low noise Low noise PG11 adaptor for connection of 7 mm cable Part No 342601 33 Triax MFA mast amplifier series High performance range of mast amplifiers with F connector F connectors on all in and outputs Simple and easy installation Releasable mast strap Attractive design in a 4 terminal waterproof masthousing Wide range with 1 2 or 3 inputs and 1 output High gain and output voltage Fixed or adjustable gain Low noise figures Unique power stabiliser enables use of any power unit from 12 V to 24 V FM notch version High output level RF shielded and CE compliant EN 50083 MFA Mast F connector Amplifiers Technical data on MFA mast amplifiers with F connectors MFA 302 MFA 304 MFA 307 MFA 308 MFA 309 MFA 310 340302 340304 340307 340308 340309 340310 Input 1 Channel Band UHF BIll UHF UHF UHF 2 UHF UHF Gain dB 20 20 30 23 33 22 28 12 22 12 22 Input 2 Channel Band VHF Bill UHF 1 Bill VHF Gain dB 12 22 13 24 12 22 12 22 12 22 Inpu
139. 12 302013 d dE Part No grey 485994 303012 303013 Part No antrazite 304012 304013 50 x 50 76 x 76 76 x 76 oe 10 pcs 10 pcs 10 pcs be TD 200 TD 26x TD 2xx bre Frames for TD outlets TYPE Frame 50 Frame 50 Frame 63 50 x 50 mm 50 x 77 mm 63 x 90 mm Part No white 302025 302026 302036 Part No grey 303025 303026 303036 Part No antrazite 304025 304026 50x5x50 76x5x76 76x5x 76 A 10 pcs 10 pcs 10 pcs i TD 200 TD 26x TD 2xx Surface mount for TD outlets TYPE Frame 50 in 50 x 77 mm d i Part No white 302046 JG Part No grey 303046 egi Part No antrazite l 50 x 25 x 50 76x25x76 10 pcs 10 pcs TD 200 TD 26x Frames for OPUS 66 outlets TYPE OPUS 66 OPUS 66 132 x 66 mm 132 x 66 mm Part No white 153147 153145 Part No grey 153146 153144 e mm 132 x 25 x 66 132 x 25 x 66 10 pcs 10 pcs horisontal mounting vertical mounting Surface mount for OPUS outlets TYPE OPUS 66 OPUS 66 66 x 66 mm 132 x 66 mm Part No white 153141 153143 za Part No grey 153140 153142 e mm 66 x 25 x 66 132 x 25 x 66 10 pcs 10 pcs single OPUS double OPUS OPUS telephone connection TYPE OPUS phone 66 x 66 mm Part No white 302780 Part No grey 303780 1 pcs 233 Accessories for GAD outlets Covers for GAD standard outlets TYPE GDZ 476 Part No 23 476 Size mm 80 x 80 Packing size 1 pcs Remar
140. 14 108010 BB minigrid ch 21 69 4 pcs per pack 23 150031 1 1 7 3 Black Double shielded 500 m drum 205 100379 Aerial 10el ch 8 15 132015 Bottom clamp 30 50 mm 69 338365 102 FF M 195 338366 102 MM E 195 100429 Aerial 10el ch 9 15 132018 Bottom clamp 60 mm 69 e 100479 Aerial 10el ch 10 15 300738 Cable 1m A V Nicam for TDH 111 251493 19 TCC cabinet with glass door 123 E 100229 Aerial 10el ch 5 14 C 251494 19 TCC cabinet with steel door 123 100529 Aerial 10el ch 11 15 251512 19 TMF 512 open rack cabinet 124 100282 Aerial 13el Se 6 14 300738 Cable 1m A V Nicam for TDH 111 152015 2 x 0 5 power cable grey 213 100482 Aerial 13el eh 10 15 300749 Cable 1 5 m A V in out for TDH 111 152010 2 x0 5 power cable white 213 100332 Aerial 13el cacy 14 300746 Cable 2 0m video monitor TDH 111 152003 2 x 0 75 power cable grey 213 100382 Aerial 13el EE 8 15 153082 Cable clips black FC 11 13 pack with 100 pcs 73 152004 2 x 0 75 power cable white 213 100432 Aerial 13el ch 9 15 153083 Cable clips black FC 13 15 pack with 100 pcs 73 338106 203B 2 Splitter 195 100532 Aerial 13el ai 15 153084 Cable clips black FC 15 17 pack with 100 pcs 73 345110 2TV 166 400232 Aerial 13el ch5 4 153081 Cable clips black FC 9 11 pack with 100 pcs 73 345111 2TV Plus 166 104602 Aerial Zel h 5 6 13 153004 Cable clips Natural 6 25 pack with 100 pcs 73 338125 309 3 Splitter 195 153008 Cable clips Natural 7 25 pack with 100 pcs 73
141. 16 346320 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 Outputs pcs 3 3 3 3 Insertion loss in out 5 40 MHz dB lt 3 9 lt 2 3 lt 1 1 lt 0 9 40 470 MHz dB lt 4 0 lt 2 4 lt 1 3 lt 1 0 470 750 MHz dB lt 4 2 lt 2 6 lt 1 5 lt 1 1 750 860 MHz dB lt 4 4 lt 2 8 lt 17 lt 1 3 860 1000 MHz dB lt 4 6 lt 3 0 lt 2 0 lt 1 5 Tap loss in tap 5 40 MHz dB 10 0 1 0 12 0 41 0 16 0 1 0 20 0 1 0 40 470 MHz dB 10 0 1 0 12 0 41 0 16 0 1 0 20 0 1 0 470 750 MHz dB IDO 1 0 12 0 41 2 16 0 1 0 20 0 1 0 750 860 MHz dB 10 0 1 2 12 0 1 5 16 0 1 2 20 0 1 2 860 1000 MHz dB 10 0 1 5 12 0 2 0 16 0 1 5 20 0 1 5 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 26 0 gt 26 0 gt 26 0 gt 26 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 860 1000 MHz dB gt 24 0 gt 24 0 gt 24 0 gt 24 0 Isolation out tap 5 40 MHz dB gt 30 0 gt 35 0 gt 30 0 gt 34 0 40 470 MHz dB gt 26 0 gt 28 0 gt 30 0 gt 32 0 470 750 MHz dB gt 25 0 gt 26 0 gt 28 0 gt 30 0 750 860 MHz dB gt 23 0 gt 25 0 gt 26 0 gt 27 0 860 1000 MHz dB gt 23 0 gt 24 0 gt 25 0 gt 26 0 Return loss in out 5 40 MHz dB gt 22 0 gt 20 0 gt 22 0 gt 22 0 40 470 MHz dB gt 18 0 gt 20 0 gt 22 0 gt 22 0 470
142. 17 185 Triax TDP delivery point for TV R and data Triax delivery point for separating TV R and data signals Mount a Triax TDP delivery point on the main connection cable to your SMATV system and get a stabile and secure separation of your signal to your tv radio and cable modem e High isolation e Low insertion loss e Class A shielding Technical data on TDP delivery points Frequency range MHz 5 1000 5 1000 Outputs pcs TV R Data TV R Data Insertion loss 5 40 MHz dB 4 0 40 1000 MHz dB 4 0 Tap loss 5 40 MHz dB 2 0 40 1000 MHz dB 7 0 Isolation 5 40 MHz dB gt 50 0 gt 50 0 40 1000 MHz dB gt 50 0 gt 50 0 Return loss 1 5 dB octav 5 40 MHz dB gt 20 0 gt 20 0 40 1000 MHz dB gt 20 0 gt 20 0 Shielding efficiency dB Class A 100 0 Class A 100 0 Power pass No No Connectors F connector F connector Certification CE CE Impedance Ohm 75 75 Weight kg 0 063 0 063 Dimensions h x d x w mm 50 x 16 x 74 50 x 16 x 74 186 Triax splitter TLS series outdoor Outdoor trunk splitter with frequency ranges from 5 to 1000 MHz e All ports impedance 75 Ohm In out current passing 10 A 60 VAC The 100 dB RFI integrity is maintained by the use of tongue and groove design and with a stainless steel mesh RFI gasket Continual power through between input and output Aluminum alloy housing is finished with a baked acryl
143. 17 60x 16x 117 78 x 44 x 242 78 x 44 x 242 174 Triax taps HTT series 5 1000 MHz E KLASSE CLASS HTT 1 8 HTT 1 12 HTT 1 16 HTT 1 20 HTT 1 24 347108 347112 347116 347120 347124 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 1 1 1 1 1 1 Insertion loss in out 5 40 MHz dB lt 2 5 lt 1 5 lt 0 9 lt 0 7 lt 0 7 lt 0 7 40 470 MHz dB lt 2 5 lt 1 7 lt 0 9 lt 0 7 lt 0 7 lt 0 7 470 860 MHz dB lt 2 7 lt 2 2 lt 1 2 lt 0 9 lt 0 9 lt 0 9 Tap loss in tap 5 40 MHz dB 6 5 1 0 8 5 1 0 12 5 1 0 16 0 1 0 20 0 1 0 24 0 1 0 40 470 MHz dB 6 0 1 0 8 5 1 0 12 0 1 0 16 0 1 0 20 0 1 0 24 0 1 0 470 860 MHz dB 6 0 1 2 8 8 1 5 12 0 1 5 16 0 1 5 20 0 41 5 24 0 1 5 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 Isolation out tap 5 40 MHz dB gt 20 0 gt 25 0 gt 30 0 gt 32 0 gt 35 0 gt 35 0 40 470 MHz dB gt 22 0 gt 25 0 gt 28 0 gt 28 0 gt 32 0 gt 32 0 470 860 MHz dB gt 20 0 gt 22 0 gt 25 0 gt 30 0 gt 30 0 gt 30 0 Return loss in out 5 40 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 40
144. 2 180 Triax splitter STS series 5 2400 MHz STS 2 STS 3 STS 4 STS 6 STS 8 348002 348003 348004 348006 348008 Frequency range MHz 5 2400 5 2400 5 2400 5 2400 5 2400 Outputs pcs 2 3 4 6 8 Insertion loss in out 5 40 MHz dB lt 4 2 lt 7 2 lt 8 2 lt 11 2 lt 11 7 40 1000 MHz dB lt 4 7 lt 7 7 lt 8 2 lt 11 7 lt 12 2 1000 1750 MHz dB lt 6 2 lt 9 7 lt 10 2 lt 11 7 lt 15 2 1750 2150 MHz dB lt 6 5 lt 10 7 lt 10 9 lt 16 7 lt 18 0 2150 2400 MHz dB lt 6 7 lt 11 2 lt 12 5 lt 16 7 lt 18 2 Return loss in 5 40 MHz dB gt 18 0 gt 14 0 gt 14 0 gt 14 0 gt 14 0 40 1000 MHz dB gt 17 0 gt 18 0 gt 18 0 gt 14 0 gt 14 0 1000 1750 MHz dB gt 15 0 gt 15 0 gt 15 0 gt 16 0 gt 16 0 1750 2150 MHz dB gt 14 0 gt 15 0 gt 16 0 gt 15 0 gt 15 0 2150 2400 MHz dB gt 15 0 gt 14 0 gt 16 0 gt 16 0 gt 15 0 Return loss out 5 40 MHz dB gt 16 0 gt 18 0 gt 18 0 gt 18 0 gt 20 0 40 1000 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1000 1750 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 1750 2150 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 2150 2400 MHz dB gt 17 0 gt 17 0 gt 17 0 gt 17 0 gt 18 0 Shielding efficiency VHF UHF dB 110 0 110 0 110 0 110 0 110 0 Power pass All All All All All Connectors F connector F connector F connector F connec
145. 2 1 1 Frequency range Sat MHz 900 2150 920 2150 900 2150 920 2150 Ter MHz Switch type DiSEqC control Through loss dB typ 1 5 8 0 4 0 typ 1 5 3 0 typ 1 5 8 0 Isolation input A B dB gt 10 gt 20 gt 10 gt 40 Return loss dB Linearity dB Function s position tone burst position position option position tone burst mini DiSEqC mini DiSEqC DC loop through mA Current consumption mA 25 20 25 25 Temperature range u 30 60 30 60 30 60 30 60 Dimensions H x D x W mm Weight kg Remarks DC feedthrough Hi lso switch 24V 250 mA a BS E DiSEqC 506 Hi Iso 300506 Priority switch 300503 94 Polarmount SatSelect and LNB covers Triax s range of accessories for perfect installations Polarmount for TD dishes Used with a motor for adjusting the elevation of the TD dish on one axis and access to all geostationary satellites along this axis SatSelect motor for TD dishes A motor for turning the TD dish on one axis and which gives you access to all geostationary satellites along this axis Para Protection will cover your LNB units Mist rain snow hoarfrost road dust and pollen that lays on the LNBs can make a reduction in quality of the TV pictures A bowed perspex sheet held to the LNB arm gives the LNBs very effective protection against bad weather and climate The result The pictur
146. 2 12 Length mm 120 200 300 400 Material Galv steel Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 1 Remarks incl disc incl disc incl disc incl disc extra extra 1 2 and nuts and nuts and nuts and nuts disc nuts GN A 68 Steel wire and accessories Technical data on accessories Botton clamp Botton clamp Mast bracket Mast bracket Stay ring 30 50 mm 60 mm 15x15 60 18x18 60 132015 132018 133262 133252 133010 Mast diameter mm 30 50 30 50 30 50 30 50 30 50 Material Galv steel Galv steel Steel Steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 Remarks Tilt mast bracket Tilt mast bracket 3 point aerials beam aerials beam Technical data on galvanized steelwire Steel wire Steel wire Steel wire Steel wire Steel wire galvanized galvanized galvanized PVC covered galvanized 133007 133105 133020 133005 133002 Diameter mm 3 5 5 1 2 2 3 5 Material Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 Remarks Roll of 55 m Length of Length as Roll of oilfree or 220 m 3 6m required 100 m Rigging Wirelock Wirelock Thimble Thimble screw 133015 133025 133021 133009 133008 Diameter mm 1 4 3 5 3 5 Material Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 Remarks Fits Fits Fits 3 mm wi
147. 2 33 ch 35 69 SDP DA AGNANO 311166 TMC 3941 group combiner VHF BI dB gt 20 gt 20 gt 20 ch 2 39 ch 41 69 FM dB gt 20 gt 20 gt 20 deko BIII dB gt 20 gt 20 gt 20 311167 TMC 2831 group combiner UHF dB gt 20 gt 20 gt 20 ch 2 28 ch 31 69 SAT dB 311168 TMC 5052 group combiner Numbers of in output 2 1 2 1 2 1 ch 2 50 ch 52 69 DC throughpower Switchable Switchable Switchable 311169 TMC 2528 group combiner both inputs both inputs both inputs ch 2 25 ch 28 69 Connector S amp C S amp C S amp C Weight kg Dimensions Height mm Depth mm Width mm Remarks 51 Triax multi channel mast combiners TRIAX range of filters combiners When you are using the UHF series with the XX and YY channels you must remember that there must be 2 unused channels between your specified XX and YY UHF chan nels 7000 mast combiner filter with clamp TRIAx FILTER TYPE UHF CH XX Rest VHF UHF OUT O6 8 OF OP Etre Erie IMIS A A T5XY 7000 FXX 70XX FYY 70XX FYY DCF 4 x UHF BIll 21 40 BIII 41 60 x Foy BAG E 312150 312250 312264 312263 317570 Input 1 Band BIII UHF BIII BIII UHF Channel 1 ch X 1 ch X 1 ch A 1 ch A CH 31 53 Through loss dB 2 0 3 0 2 0 2 0 3 0 Input 2 Band Bill UHF UHF UHF rest Channel 1ch Y 1 ch XX 1 ch XX 1 ch XX VHF UHF Through loss
148. 2 50x16x52 182 E KLASSE CLASS Triax taps STT series 5 2400 MHz STT 2 10 STT 2 12 STT 2 16 STT 2 20 348210 348212 348216 348220 Frequency range MHz 5 2400 5 2400 5 2400 5 2400 Outputs pcs 2 2 2 2 Insertion loss 5 40 MHz dB lt 4 2 lt 2 lt 2 lt 1 7 40 1000 MHz dB lt 3 2 lt 2 lt 2 lt 1 7 1000 1750 MHz dB lt 4 2 lt 3 2 lt 3 7 lt 2 7 1750 2150 MHz dB lt 4 7 lt 4 2 lt 4 2 lt 3 2 2150 2400 MHz dB lt 5 5 lt 4 7 lt 4 5 lt 4 0 Tap loss 5 40 MHz dB 11 0 2 0 12 0 42 0 15 0 42 0 20 0 2 0 40 1000 MHz dB 10 5 1 5 12 0 41 5 15 0 41 5 20 0 1 5 1000 1750 MHz dB 10 5 1 5 12 0 41 5 15 0 41 5 20 0 1 5 1750 2150 MHz dB 10 5 2 0 12 0 42 0 15 0 42 0 20 0 2 0 2150 2400 MHz dB 10 5 2 0 12 0 42 5 15 0 42 5 20 0 2 5 Isolation 5 40 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 40 1000 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 1000 1750 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 1750 2150 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 2150 2400 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 28 0 Return loss in out 5 40 MHz dB gt 18 0 gt 22 0 gt 22 0 gt 23 0 40 1000 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 22 0 1000 1750 MHz dB gt 18 0 gt 20 0 gt 20 0 gt 22 0 1750 2150 MHz dB gt 16 0 gt 18 0 gt 20 0 gt 20 0 2150 2400 MHz dB gt 16 0 gt 18 0
149. 2 female PG 3512 158 339503 IFP 503 198 340304 MFA 304 UHF 34 153580 PG11 male to Female PGF 158 339504 IFP 504 198 340407 MFA 307 IFP 502 38 130020 Phone mast bracket 68 339505 IFP 505 198 340507 MFA 307 IFP 503 24V 38 140128 Pipe holder for bottom pipe 63 339529 IFP 529 Power inserter 199 340307 MFA 307 UHF 34 129421 Plastic parts for TD dish Black 88 339529 IFP 529 power inserter 197 340308 MFA 308 UHF 34 129420 Plastic parts for TD dish Ral 7030 88 339434 IIB 434 165 340409 MFA 309 IFP 502 38 129422 Plastic parts for TD dish Ral 7035 88 339435 ID 435 165 340309 MFA 309 UHF 34 712290 PLT 2S black 74 339445 IIB 445 165 340410 MFA 310 IFP 502 38 153067 PLT 2smo 4 8x188 048 Black 74 132213 Index black 71 340310 MFA 310 UHF 34 153068 PLT 3H 7 6x290 076 74 132212 Index red 71 340411 MFA 311 IFP 502 38 712296 PLT 3H Black 74 132210 Index R79 big 71 340511 MFA 311 IFP 503 24V 38 153066 PLT 4smo 4 8x368 0102 Black 74 13211 Index R79 small 71 340311 MFA 311 UHF 35 124078 Polar Mount for satellite dishes 95 111000 Indoor Aerial 47 860 MHz 30 340312 MFA 312 35 153616 Power coupling 213 JKL 340412 MFA 312 IFP 502 38 153310 Power plug female 213 130010 Jaw bracket universal 68 sues e GR cle d Sa ak 322200 JXP OT200 155 340413 MFA 313 IFP 502 38 153320 Power point 2 way grey 213 340513 MFA 313 IFP 503 24V 38 153322 Power point 3 way grey 213 322201 JXP OT201 155 309902 JXP OT202 155 340314 MFA 314 35 153340 Pow
150. 22 28 28 22 22 Isolation cross polarisation H V dB 25 28 28 25 25 Isolation out out TER dB 30 28 28 28 28 Isolation out out SAT dB 30 35 35 35 35 Return loss SAT inputs dB 12 11 11 11 10 Return loss SAT outputs dB 7 9 9 8 8 Return loss TER inputs dB 11 11 11 11 10 Return loss TER outputs dB 7 9 9 8 8 Output level SAT IMD3 35 dB GEUN 100 101 101 100 100 Output level TER IMD3 60 dB GEUN 88 85 85 85 85 Impedance input output Ohm 75 75 75 75 75 Switching VDC 13 V 18V 13 V 18V 13 V 18V 13 V 18V 13 V 18V 13 V 22 kHz 13 V 22 kHz 13 V 22 kHz 13 V 22 kHz 13 V 22 kHz 18 V 22 kHz 18 V 22 kHz 18 V 22 kHz 18 V 22 kHz 18 V 22 kHz Supply voltage VDC 15 0 5 15 0 5 15 0 5 15 0 5 15 0 5 Power supply Included Included Included Included Included LNB power supply max mA 600 600 600 600 600 Colourcoding of IF and TER Inputs Yes Yes Yes Yes Yes Temperature range GE 0 55 0 55 0 55 0 55 0 55 Dimensions H x D x W mm 103x71x249 103x71x359 103x71x359 103x71x459 103x71 x559 g ZZ wl Zk e Zt ma po KO Se ee ERAN eee el DEE oo Ee ww TMS SNEP b TMS 5X16p T Triax TMS 2x multiswitches 1 position 2 polarity switch many users and expandability For systems with one satellite position Simple yet expandable Easy to install TMS Se TMS 2x4C Technical data Cascadable multiswitches with 2 polarities External power supply
151. 2200 MHz TOU satellite outlet housing TYPE TOU 01S TOU 10S TOU 14S Part No incl cover White 303661 303670 303674 Part No excl cover 303662 303675 Outputs TV Radio TV Radio TV Radio SAT SAT SAT Frequency range TV MHz 5 74 120 862 5 74 120 862 5 74 120 862 Radio MHz 87 5 108 87 5 108 87 5 108 SAT MHz 950 2250 950 2250 950 2250 Through loss TV dB 1 5 2 0 Radio dB 1 5 2 0 SAT dB 3 5 3 5 Tap loss TV dB 2 0 10 0 14 0 Radio dB 1 5 10 0 14 0 SAT dB 2 0 10 0 14 0 Isolation TV Radio dB gt 15 gt 20 gt 20 TV SAT dB gt 25 gt 25 Radio SAT dB gt 30 gt 30 Out Radio dB Out TV dB gt 10 gt 10 gt 10 Out SAT dB Return loss TV EN 50083 4 dB Cat C Cat C Cat C Radio EN 50083 4 dB Cat D Cat D Cat D SAT dB Shielding factor VHF dB gt 85 0 gt 85 0 gt 85 0 UHF dB gt 75 0 gt 75 0 gt 75 0 SAT dB Connectors TV lIEC male IEC male IEC male Radio lIEC female IEC female lIEC female SAT F female F female F female DC through In SAT V mA 20 500 20 500 20 500 Standards CE EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 Weight kg 0 156 0 156 0 156 Dimensions mechanical mm O60 O60 60 Remarks Please refer to page 232 for cover frame and terminators According to CENELEC C 5 40 MHz gt 14 dB 40 862 MHz min 14 dB 1 5 oct D 5 862 MHz gt 10 dB 220 Triax TD tv radio outlets Triax s FUGA TV ra
152. 22203 3 3 Tall orange JXP OT204 322204 4 4 Tall orange JXP OT205 322205 5 5 Tall orange JXP OT206 322206 6 6 Tall orange JXP OT207 322207 7 7 Tall orange JXP OT208 322208 8 8 Tall orange JXP OT209 322209 9 9 Tall orange JXP OT210 322210 10 10 Tall orange JXP OT211 322211 11 Tall orange JXP OT212 322212 12 11 5 Tall orange JXP OT213 322213 13 Tall orange JXP OT214 322214 14 13 Tall orange JXP OT215 322215 15 Tall orange JXP OT216 322216 16 14 5 Tall orange JXP OT217 322217 17 Tall orange JXP OT218 322218 18 16 Tall orange JXP OT219 322219 19 Tall orange JXP OT220 322220 20 17 Tall orange JXP OT221 322221 21 Tall orange JXP OT222 322222 22 18 5 Tall orange JXP OT223 322223 23 Tall orange JXP OT224 322224 24 20 Tall orange JXP OT225 322225 25 Tall orange JXP OT226 322226 26 Tall orange Accessory box 322230 Box with pads and other accessories Interstage modules Interstage attenuation and equalisation combined Part No Attenuation Tilt Description HIS OEI 606 MHz MEX 600 06 322260 0 3 6 Pivot point at 606 MHz MEX 602 06 322262 2 6 Pivot point at 606 MHz MEX 604 06 322264 4 6 Pivot point at 606 MHz MEX 606 06 322266 6 6 Pivot point at 606 MHz 862 MHz MEX 800 08 322280 0 3 8 Pivot point at 862 MHz MEX 802 08 322282 2 8 Pivot point at 862 MHz MEX 804 08 322284 4 8 Pivot point at 862 MHz MEX 806 08 322286 6 8 Pivot point at 862 MHz 155 Triax Accessories for am
153. 230 0 230 0 230 0 230 0 230 Dimensions Height mm 108 108 108 108 108 108 Depth mm 50 50 50 50 50 50 Width mm 120 120 120 120 120 120 Remarks Low noise Low noise Low noise Low noise Low noise 36 Triax MFA mast amplifier series High performance range of mast amplifiers with F connector F connectors on all in and outputs Simple and easy installation Releasable mast strap Attractive design in a new 6 terminal improved waterproof masthousing Wide range with 1 2 3 or 4 inputs and 1 output High gain and output voltage Fixed gain Low noise figures Unique power stabiliser enables use of any power unit from 12 V High output level RF shielded and CE compliant EN 50083 UHF wide band amplifier MFA 651 e 1 UHF input e 5V power supply from DVB T receiver via output or from LNB power via i e Triax MFC 151 combiner Technical data on MFA mast amplifiers with F connectors MFA 606 MFA 608 MFA 615 MFA 625 MFA 651 DVB T 340606 340608 340615 340625 340651 Input 1 Frequency MHz 470 862 470 862 470 862 470 862 470 862 Channel Band UHF UHF UHF UHF UHF Gain dB 6 8 15 25 12 Input 2 Channel Band Gain dB Input 3 Channel Band Gain dB Input 4 Channel Band Gain dB Noise figure UHF dB 2 5 2 5 2 5 2 5 1 8 VHF dB Max output voltage 60 dB IMA dBuyuV 4x95 103 105 105 105 Numbers of in output 1 4 1 1 1 1 1 1 1 1 Voltage VDC 12 12 12 12 5 12 Power mA 30 30 30 65 15 Switchabl
154. 242 SCA 2052 1 333252 SCA 2064 1 333264 333223 SCA 2033 1 333233 SCA 2043 1 333243 SCA 2053 1 333253 SCA 2065 1 333265 333224 SCA 2034 1 333234 SCA 2044 1 333244 SCA 2054 1 333254 SCA 2066 1 333266 333225 SCA 2035 1 333235 SCA 2045 1 333245 SCA 2055 1 333255 SCA 2067 1 333267 SCA 2068 1 333268 333226 SCA 2036 1 333236 SCA 2046 1 333246 SCA 2056 1 333256 SCA 2069 1 333269 333227 SCA 2037 1 333237 SCA 2047 1 333247 SCA 2057 1 333257 333228 SCA 2038 1 333238 SCA 2048 1 333248 SCA 2058 1 333258 333229 SCA 2039 1 333239 SCA 2049 1 333249 SCA 2059 1 333259 333230 SCA 2040 1 333240 SCA 2050 1 333250 SCA 2060 1 333260 47 Triax FM and VHF single channel amplifiers TRIAX s FM amplifier The TRIAX FM amplifier model A88108A1 is RF shielded and is in a grey waterproof box for wall or mast installation This amplifier is designed for the reception of very weak FM radio stations and it incorporates a built in combiner for band TRIAX s VHF 1 channel amplifier Triax single channel VHF amplifier model AXX A1 is RF shielded and in a grey waterproof box for wall or mast installation Due to its high selectivity and immunity to interference this amplifier is designed for long distance reception of weak TV stations in areas where there are strong signals from local stations The amplifier is available for each channel from 4 to 12 by exchanging XX with the specific TV channel num
155. 3 77 77 79 e mail sales triax co uk web www triax co uk Triax Middle East PO Box 18351 Dubai UAE Tel 971 4 887 3100 Fax 971 4 887 3101 e mail triax triax ae web www triax ae Triax Hirschmann Multimedia which is a part of the Triax Group is together with Triax one of the leading European suppliers of TV reception and distribution systems and enclosures Triax is ISO 9001 2000 certified and delivers products in accordance with all acknowledged local and international quality standards Triax is also certified in accordance with DS EN ISO 14001 Gu lanerd more simply TRIAX A S Bjornkeervej 3 DK 8783 Hornsyld Tel 45 76 82 22 00 Fax 45 75 68 79 66 e mail triax triax dk www triax com Q OO E SKO OO dE a 0 SU S Be O ebei d Q ZO SU Ke A E E d ebei A E O OO Q lt J N de GZ LO E Sa lt Triax Marketing e 2005 The Triax Group es All rights reserved Use of this material signifies your agreement to the terms of use
156. 31437 SCF 49 15A3 331449 SCF 26 15A3 331426 SCF 38 15A3 331438 SCF 50 15A3 331450 SCF 62 15A3 331462 SCF 27 15A3 331427 SCF 39 15A3 331439 SCF 51 15A3 331451 SCF 63 15A3 331463 SCF 28 15A3 331428 SCF 40 15A3 331440 SCF 52 15A3 331452 SCF 64 15A3 331464 SCF 29 15A3 331429 SCF 41 15A3 331441 SCF 53 15A3 331453 SCF 65 15A3 331465 SCF 30 15A3 331430 SCF 42 15A3 331442 SCF 54 15A3 331454 SCF 66 15A3 331466 SCF 31 15A3 331431 SCF 43 15A3 331443 SCF 55 15A3 331455 SCF 32 15A3 331432 SCF 44 15A3 331444 SCF 56 15A3 331456 57 Triax single notch stop filters SCS standard rejection notch filters are 1 channel UHF notch filters intended for rejection of the signal from a strong local transmitter e New attractive housing e Releasable mast strap e Mast or wall mounting e RF shielded SCS Single Channel Stopfilter SCS single channel notch stop filter Technical data on SCS single channel stop filter with saddle and clamp connectors SCS 7000 21 SCS 7000 39 SCS 7000 58 314021 314039 314058 Input 1 Band VHF UHF VHF UHF VHF UHF Stop channel 21 39 58 Through loss dB 0 5 1 0 0 5 1 0 0 5 1 0 Input 2 Band Stop channel Through loss dB Rejection Channel dB gt 20 gt 20 gt 20 Numbers of in output 2 1 2 1 2 1 DC throughpower VHF UHF VHF UHF VHF UHF Connector S amp C S amp C S amp C Weight kg 0 2 0 2 0 2 Dimensions Height mm 90 90 90 Depth mm 48 48 48 Width mm 115 115 115 All SCS 7000
157. 317401 317402 317240 317241 317242 Input 1 Band UHF UHF UHF UHF UHF UHF Channel Ch 21 69 Ch 21 69 Ch 21 69 Ch XXYY Ch XXYY Ch XXYY Through loss dB 3 0 3 0 3 0 4 0 4 0 4 0 Input 2 Band rest rest rest rest UHF rest UHF rest UHF Channel VHF UHF VHF UHF VHF UHF 21 60 21 60 21 60 Through loss dB 1 0 1 0 1 0 1 5 1 0 1 0 Input 3 Band BIII VHF VHF Channel 5 12 2 12 2 12 Through loss dB 1 0 1 0 1 0 Input 4 Band BI FM Channel Through loss dB 1 0 Stop band attenuation VHF BI dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 FM dB gt 20 Bill dB gt 20 UHF dB gt 20 gt 20 gt 20 gt 20 gt 20 gt 20 SAT dB Numbers of in output 2 1 2 1 2 1 4 1 3 1 3 1 DC throughpower Ch XXYY rest Ch XXYY Switchable Ch XXYY Ch XXYY VHF UHF rest VHF UHF all inputs rest UHF Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 2 0 2 0 2 0 2 0 2 0 2 Dimensions Height mm 90 90 90 90 90 90 Depth mm 48 48 48 48 48 48 Width mm 115 115 115 115 115 115 Remarks There must be 2 unused channels between your specified XX and YY UHF channels 53 Triax multi channel mast combiners TRIAX range of filters combiners When you are using e g the F 3153 00 A1 filter you must remember that on the rest UHF input there must be 2 unused channels on each side of channel 31 and channel 53 TRIAX KO T
158. 32 343916 TTM 16 180 107205 YAGI 6el ch 21 69 with F connector 18 300347 TMS 9x16p 133 140007 Tube 50mm 95 cm 96 300357 TMS 9x16p UK 133 340110 TV SAT diecast housing 50 300364 TMS 9x4C 132 345100 Type 02 166 300344 TMS 9x4p 133 U 300354 TMS 9x4p UK 133 140035 U clamp 68 300366 TMS 9x6C 132 109690 UFO 45 Digital UHF IFP501 27 300346 TMS 9x6p 133 109694 UFO Home Digital UHF 5 V Mast bracket 27 300356 TMS 9x6p UK 133 109695 UFO Home Digital VHF UHF 5 V Mast bracket 27 300368 TMS 9x8C 132 109683 UFO Marine Digital IFP529 center mount 27 300348 TMS 9x8p 133 109680 UFO Marine Digital IFP529 universal mount 27 300358 TMS 9x8p UK 133 109699 UFO Mobil Digital 12 V Centre mount 28 336195 TMS PSU 18V 600mA phone 140 109698 UFO Mobil Digital 12 V Mast bracket 28 336196 TMS PSU 18V 600mA phone UK 140 109697 UFO Mobil Digital 5 V Centre mount 28 324900 TNH 600 Power supply 115 109696 UFO Mobil Digital 5 V Mast bracket 28 324990 TNH 600 V headend 115 108680 UHF ch 21 69 24 324904 TNH data cable 115 108678 UHF ch 21 69 mini 24 153632 Torque Wrench Spanner 209 133222 Universal mount 28 303661 TOU 01S 220 300467 Universal Quad LNB ALPS 92 303662 TOU 01S 5 pcs 220 300468 Universal Quattro LNB ALPS 92 303621 TOU 1 216 300464 Universal Single LNB ALPS 92 303630 TOU 10 217 300462 Universal Twin LNB ALPS 92 302632 TOU 10DT 219 108754 UNIX 100el ch 21 40 22 302682 TOU 10DT 5 pcs 219 108755 UNIX 100e
159. 335 Ch 35 36 TDH channel filter 301337 Ch 37 38 TDH channel filter 301339 Ch 39 40 TDH channel filter 301341 Ch 41 42 TDH channel filter 301343 Ch 43 44 TDH channel filter 301345 Ch 45 46 TDH channel filter 301347 Ch 47 48 TDH channel filter 301349 Ch 49 50 TDH channel filter 301351 Ch 51 52 TDH channel filter 301353 Ch 53 54 TDH channel filter 301355 Ch 55 56 TDH channel filter 301357 Ch 57 58 TDH channel filter 301359 Ch 59 60 TDH channel filter 301361 Ch 61 62 TDH channel filter 301363 Ch 63 64 TDH channel filter 301365 Ch 65 66 TDH channel filter 301367 Ch 67 68 TDH channel filter e eri Triax connection cables i TZ USB cable 50 cm USB cable 100 cm RF cable 20 cm RF cable 35 cm Technical data on TDH connection cable USB cable USB cable RF cable RF cable A to B A to B 20 cm 35 cm 453160 453161 452090 452091 Lenght cm 50 100 20 35 Packing QTY pcs 1 1 1 1 Remarks A to B connection A to B connection Connection from Connection from for TDH 701 sub for TDH 701 sub splitter multi switch splitter multi switch to TDH modules to TDH modules Video audio 15 cm Video audio 150 cm Video audio 150 cm Modulator 150 cm Video audio 200 cm Technical data on TDH connection cable Video audio Video audio Video audio Video audio Video audio
160. 38 239 Basic technical requirements 243 Triax digital links 240 Technical data in the catalogue 244 Planning and installation 245 246 Earthing and equipotential 247 Frequency range of waves 247 TV standards 247 Channels and frequencies 248 249 Colour and broadcasting 250 Signal level mV to dBuV 251 Frequency for radio TV channels 251 General sales and delivery conditions 258 259 Construction and type overview Aerials Continuous development is taking place in the field of terrestrial aerials requiring us always to stay one step ahead Our development and design expertise enables us to develop new products quickly for changing markets TRIAX develops and produces a wide range of aerials covering the VHF and UHF frequency bands In our development work we utilise the latest technology of computer simulation and testing TRIAX aerials are manufactured with the utmost accuracy to ensure maximum gain TRIAX aerials comply with the DS EN 50083 1 standard and are fatigue tested by exposure to more than 100 000 vibrations at the physical resonant frequency and to salt mist in order to ensure long life even under the most hostile weather conditions Construction and type overview For the mechanical construction of all TRIAX aerials a strong and stable aluminium boom is used The dipole and elements are mounted with a strong bracket made of metal or plastic The dipole is mounted with a cable housing made of pol
161. 4 18 14 18 14 18 14 18 14 18 kHz 0 22 0 22 0 22 0 22 0 22 0 22 Software download 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D 15 pol SUB D Impedance Ohm 75 75 75 75 75 75 Operation temperature range C 0 50 0 50 0 50 0 50 0 50 0 50 Weight kg 0 282 0 282 0 282 0 282 0 282 0 282 Dimensions H x D x W mm 75x190x45 75x190x 45 75x 190x45 75x190x45 75x190 x45 75x 190 x 45 114 Technical data TNH 600V 6 channel complete premounted headend TNH 600 Triax modular digital headend TNH 600 is the solution when a simple cost efficient conversion from DVB T to analogue with NICAM sound is required The modular design makes it easy to adapt the system to the required number of programmes The system is designed with a powerful switch mode power supply which supplies from 1 to 6 modules from separate outputs TNH 600 V headend 324990 Tz Input frequency range MHz 177 858 i Output frequency range MHz 174 300 Output channels E5 E12 811 820 TNH 600V Output level combined EON 83 Output level adjustment dB 0 15 Modulator type DSB Antenna input IEC female male Antenna output F hun TV standard B Audio system NICAM ANT control off Power supply from mains unit IR remote control eye internal Weight kg 12 4 Dimensions per module HxDxB mm 315 x 190 x 420 Connection cables and combiner included Technical data Powe
162. 4115 UP LINK 238 Technical data Triax Domestic Distribution Unit TYPE Part No Triax Domestic Distribution Unit DDU DDU 112 333112 Inputs to downlink BI FM BIII DAB 2 x UHF SAT 1 Frequency range MHz 47 108 174 230 470 862 950 2300 Gain dB 10 10 8 8 Linearity dB 2 2 2 de Noise figure dB 4 4 8 3 5 Output voltage 60 dB IMD dBuV 93 93 93 Output voltage 35 dB IMD dBuV 100 Return loss input dB gt 10 gt 10 gt 10 gt 10 output dB gt 10 gt 10 gt 10 gt 10 Sat input to uplink out 7 amp out 8 SAT 2 SAT 3 SAT 4 Frequency range MHz 950 2300 950 2300 950 2300 Gain dB 10 8 8 Linearity dB 2 t2 t2 Noise figure dB 3 5 3 5 3 5 Output voltage 35 dB IMD dBuV 100 100 100 Return loss input dB gt 10 gt 10 gt 10 output dB gt 10 gt 10 gt 10 Uplink to outputs UHF forw LINK ret Frequency range MHz 470 862 5 30 Gain dB 6 6 Linearity dB 2 2 Noise figure dB 4 3 5 Output voltage 60 dB IMD dBuv 93 93 Return loss input dB gt 10 gt 10 output dB gt 10 gt 10 Inputs to outputs R TV1 4 BI FM BIDAR Frequency range MHz 47 108 174 230 Gain dB 6 6 Linearity dB 2 D Noise figure dB 4 4 Output voltage 60 dB IMD dBuV 93 93 Output voltage 35 dB IMD dBuV Return loss input dB gt 10 gt 10 output dB gt 10 gt 10 Inputs to outputs R TV 5 8 BI FM BIII D
163. 490722 590723 Pal 490702 590743 490722 591623 Modulator type VSB VSB VSB VSB Input frequency range MHz 920 2150 920 2150 920 2150 920 2150 Input level GEUN 44 84 44 84 44 84 d BA IF bandwidth MHz 36 36 36 36 Output channel 2 69 2 69 2 69 2 69 frequency range MHz 47 862 47 862 47 862 47 862 Output level SA modules dBuV 103 103 103 103 Output level attenuator dB 10 10 10 10 Video S N ratio dB gt 54 gt 54 gt 54 gt 54 Differential phase deg lt 8 lt 8 lt 8 lt 8 Picture carrier stability kHz lt 70 lt 70 lt 70 lt 70 Spurious signals ref pict carrier C N dB gt 60 gt 60 gt 60 gt 60 Sound mode Mono A2 stereo Nicam Mono A2 stereo Nicam Audio distortion 1 kHz lt 1 lt 1 lt 1 lt 1 Audio S N ratio dB gt 50 gt 50 gt 50 gt 50 Sound sub carrier stability kHz lt 5 lt 5 lt 5 lt 5 LNB control 13 18 volt 0 22 kHz mA 200 200 200 200 Conditional access EN 50221 50221 FTA FTA Teletext type Reinserted in VBI Reinserted in VBI Reinserted in VBI Reinserted in VBI Demultiplexer data rate Mbps lt 65 lt 65 lt 65 lt 65 Video data rate Mbps lt 15 lt 15 lt 15 lt 19 Viterbi rates Mpps 1 30 SCPC MCPC 1 30 SCPC MCPC 1 30 SCPC MCPC 1 30 GCPC MCPC Impedance Ohm 75 75 75 75 Operation temperature range GE 10 50 10 50 10 50 10 50 Power supply stand alone module VAC 190 260 190 260 190 260 190 260 Weight standard
164. 5 built in 18 via DC plug 18 15 or trunk via DC plug via trunk Power supply Internal External External power adaptor power adaptor Colourcoding of IF and TER inputs Yes Temperature range EE 0 55 0 55 0 55 0 55 Dimensions H x D x W mm 140 x 121 x 250 125 x 53 x 170 139 Triax TMS power supplies TMS power supply power inserter Triax TMS 5 PSU is an easy to install power supply power inserter to be used with the TMS 5x series products TMS 5 PSU TMS 17 PSUMB w mounting bracket Technical data TMS power supply power inserter TYPE TMS 17 PSU MB TMS 55 PSI TMS 5 PSU TMS 55 PSU Part No EU plug 301504 300308 300309 300310 Part No UK plug 300311 Number of inputs 4 SAT 1 TER Number of outputs 1 1 4 SAT 1 TER 1 Inputs 230V 1 1 PSU included 1 Connectors F con female female female female Input voltage V AC 96 to 250 96 to 250 180 to 264 96 to 250 Frequency range Hz 47 63 47 63 47 63 47 63 Frequency range SAT MHz 950 2150 Frequency range TER MHz DC to 862 Insertion loss SAT dB 1 Insertion loss TER dB 1 Impedance input output Ohm 75 Supply direction switch terr Up down both Max current A 1x 1 3 1x 1 9 1x 1 9 Output voltage VDC 15 0 5 18 3x14 18 2x18 Supply power W 26 Cable length from supply mm 1800 1800 1800 Colourcoding of IF and TER inputs Yes Temperature range SE 0 50 0 50 0 50 0 50 Dimensi
165. 5 138 75 39 082 590 983 25 988 5 S6 139 146 140 25 145 75 36 990 598 991 25 996 75 USB S7 146 153 147 25 152 75 37 098 606 999 25 604 75 S8 153 160 154 25 159 75 38 606 614 607 25 612 75 SQ 160 167 161 25 166 75 39 614 622 615 25 618 75 S10 167 174 168 25 173 75 FV 40 622 630 623 25 626 75 Band III 5 174 181 175 25 180 75 41 630 638 631 25 636 75 6 181 188 182 25 187 75 42 638 646 639 25 644 75 7 188 195 189 25 194 75 43 646 654 647 25 652 75 8 195 202 196 25 201 75 44 654 662 655 25 660 75 9 202 209 203 25 208 75 45 662 670 663 25 668 75 10 209 216 203 25 208 75 46 670 678 671 25 676 75 11 216 223 217 25 222 75 47 678 686 679 25 684 75 12 223 230 224 25 229 75 48 686 694 687 25 692 75 Upper S11 230 237 231 25 236 75 Sa 5 E bo zeda baga S channels S12 237 244 238 25 243 75 7 51 710 718 711 25 716 75 S13 244 251 245 25 250 75 50 718 726 71925 704 75 S14 251 258 252 25 257 75 5 3 726 734 727 25 732 75 S15 258 265 259 25 264 75 BA 734 742 735 95 740 75 S16 265 272 266 25 271 75 S17 272 279 273 25 278 75 d Ge Ga Ga 56 750 758 751 25 756 75 Pilot frequency 18 279 286 57 758 766 759 25 764 75 S 19 286 293 287 25 58 766 744 767 25 772 75 S 20 293 300 294 25 299 75 59 774 782 775 25 780 75 S channels S 21 302 310 303 25 308 75 60 782 790 183 25 188 75 S 22 310 318 311 25 316 75 61 790 798 791 25 796 75 S 23 318 326 319 25 324 75 62 798 806 799 25 804
166. 5 56 5 49 75 56 25 R Il 58 66 59 25 65 75 R Ill 76 84 77 25 83 75 VHF Il RIV 84 92 85 25 91 75 RV 92 100 93 25 99 75 sl 110 118 111 25 117 75 s2 118 126 119 23 125 75 s3 126 134 127 25 133 75 s4 134 142 135 25 141 75 s5 142 150 143 25 149 75 s6 150 158 151 25 157 75 s7 158 166 159 25 165 75 s8 166 174 167 25 173 75 VHF II R VI 174 182 175 25 181 75 R VII 182 190 183 25 189 75 R VIII 190 198 191 25 197 75 R IX 198 206 199 25 205 75 RX 206 214 207 25 213 75 R Xl 214 222 215 25 221 75 R XII 222 230 223 25 229 75 s9 230 238 231 25 237 75 s10 238 246 239 25 245 75 s11 246 254 247 25 253 75 s12 254 262 255 25 261 75 s13 262 270 263 25 269 75 s14 270 278 271 25 277 15 s15 278 286 279 25 285 75 s16 286 294 287 25 293 75 s17 294 302 295 25 301 75 s18 302 310 303 25 309 75 s19 310 318 311 25 317 75 s20 318 326 319 25 325 75 s21 326 334 327 25 333 75 S22 334 342 335 25 341 75 s23 342 350 343 25 349 75 s38 462 470 463 25 469 75 Technical appendix 6 Channels and frequencies Channel Channel Video Audio limits carrier carrier MH2 MH2 MH2 VHF 1 48 5 56 5 49 75 56 25 2 56 5 64 5 57 75 64 25 3 64 5 72 5 65 75 72 25 4 76 0 84 0 17 25 83 75 5 84 0 92 0 85 25 91 75 VHF Ill 6 167 175 168 25 174 75 7 175 183 176 25 182 75 8 183 191 184 25 190 75 9 191 199 192 25 198 75 10 199 207 200 25 206 75 11 207 215 208 25 214 75 12 215 223 216 25 222 15 VHF 44 5 52 5 45 75 51 75 52 5 60 5 53 75 59 75 IC 60 5 68 5 61 75 67 75
167. 5 75 Capacitance pF m 56 52 Velocity ratio 82 84 Center conductor dc resistance Ohm km 32 22 Outer conductor dc resistance Ohm km 32 26 Attenuation at 20 C 5 MHz dB 100m 1 5 1 5 50 MHz dB 100m 11 0 4 6 200 MHz dB 100m 21 0 9 0 470 MHz dB 100m 33 9 14 4 600 MHz dB 100m 37 1 16 3 800 MHz dB 100m 44 0 18 8 1000 MHz dB 100m 49 9 21 1 1350 MHz dB 100m 58 0 24 6 1750 MHz dB 100m 66 0 28 0 2050 MHz dB 100m 80 5 30 3 2400 MHz dB 100m 87 1 32 9 Structural Return Loss SRL 5 470 MHz dB gt 20 0 gt 30 0 470 862 MHz dB gt 18 0 gt 25 0 862 2400 MHz dB gt 16 0 gt 20 0 Approval EN 50117 CEl 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes 203 Triax KOKA cable for outdoor use KOKA 100 is a HiQ universal coaxial cable for TV broadcast in house cabling The low attenuation the optimised shielding and the high return loss predestine the cable for use of both SAT IF SMATV and CATV with returnpath applications Transfer impedance less than 5 mQ m 5 30 MHz Technical data on KOKA 100 HiQ 80 and 6 CCS outdoor cable KOKA 100 KOKA 80 KOKA 6 CCS Double shielded Double shielded Double shielded Black Black Black PE EIE PE Part No Coil 100 m Reel 100 m 150186 150166 Reel 250m 150187 150167 Drum 500 m Drum 1000 feet 305 m
168. 5 mast filter ch 35 58 330502 TA 4013 30R 39 333243 SCA 2043 amp ch 43 47 314036 SCS F7000 36 mast filter ch 36 58 330487 TA 4013 322R BB AMP 39 333244 SCA 2044 amp ch 44 47 314037 SCS F7000 37 mast filter ch 37 58 330550 TA 415 22 166 333245 SCA 2045 amp ch 45 47 314038 SCS F7000 38 mast filter ch 38 58 330551 TA 415 22R 166 333246 SCA 2046 amp ch 46 47 314039 SCS F7000 39 mast filter ch 39 58 330521 TA 4213 3R 39 333247 SCA 2047 amp ch 47 47 314040 SCS F7000 40 mast filter ch 40 58 330541 TA 4312 3R 39 333248 SCA 2048 amp ch 48 47 314041 SCS F7000 41 mast filter ch 41 58 330542 TA 4312 2R 39 333249 SCA 2049 amp ch 49 47 314042 SCS F7000 42 mast filter ch 42 58 330610 TA65 3R 44 333250 SCA 2050 amp ch 50 47 314043 SCS F7000 43 mast filter ch 43 58 330606 TA 65 3 R DK 1 44 333251 SCA 2051 amp ch 51 47 314044 SCS F7000 44 mast filter ch 44 58 330603 TA 65 3 R DK DE 1 44 333252 SCA 2052 amp ch 52 47 314045 SCS F7000 45 mast filter ch 45 58 330601 TA 65 3 R DK SE 1 44 333253 SCA 2053 amp ch 53 47 314047 SCS F7000 47 mast filter ch 47 58 330604 TA 65 3 R DK SE 3 44 333254 SCA 2054 amp ch 54 47 314048 SCS F7000 48 mast filter ch 48 58 330605 TA 65 3 R DK SE A 44 333255 SCA 2055 amp ch 55 47 314049 SCS F7000 49 mast filter ch 49 58 333416 TA 9 W 3 way 43 333256 SCA 2056 amp ch 56 47 314050 SCS F7000 50 mast filter ch 50 58 153060 Tape grey roll with 10 m 74 333257 SCA 2057 amp ch 57 47 314051 SCS F7000 51 m
169. 50 241 198 339218 IFA 218 162 322252 MDA 4254 156 O 339219 IFA 219 162 322254 MDA 5573 156 339220 IFA 220 162 322256 MDA 6080 156 E E 339402 IFB 402 164 322258 MDA 6587 156 153145 Opus frame 132x66 233 339403 IFB 403 164 322246 MDIB 100 156 153144 Se frame 132x66 233 339404 IFB 404 164 251000 MDU Lock Box 8 125 302780 Opus phone connection 233 339405 IFB 405 164 251005 MDU Lock Box 16 125 begie Sb d geak See 323028 IEE 12QM distribution amplifier 161 251010 MDU Lock Box 32 125 153143 Gbe sundace mount EEE 233 323031 IFE 16Q distribution amplifier 161 322260 MEX 600 06 155 153142 Opus surlace mount 132x66 233 323022 IEE 20 distribution amplifier 161 322262 MEX 602 06 155 153141 See BEE 233 323025 EE 30 distribution amplifier 161 322264 MEX 604 06 155 13140 Opus sin ce mount oOo 233 323010 IFE 820A distribution amplifier 160 322266 MEX 606 06 155 p 323016 IFE 830A distribution amplifier 160 322280 MEX 800 08 155 PQ 323037 IEE 834C distribution amplifier 160 322282 MEX 802 08 155 336362 P601 100 199 339102 IFM 102 multiband amplifier 121 322284 MEX 804 08 155 336363 P602 100 199 339103 IFM 103 multiband amplifier 121 322286 MEX 806 08 155 300708 Para Protection for LNB Fits TD and Basic 95 339104 IFM 104 multiband amplifier 121 340402 MFA 302 IFP 501 38 300707 Para Protection for LNB Fits Unique 95 339501 IFP 501 198 340302 MFA 302 UHF 34 342601 PG 11 adaptor stacking combiners 59 339502 IFP 502 198 340404 MFA 304 IFP 502 38 153581 PG11 male to 351
170. 50181 150161 Reel 250m 150182 150162 Drum 500 m 150193 150173 Drum 1000 feet 305 m Center conductor mm 1 13 l 1 02 Center conductor material Cu blank Cu blank Isolation mm 4 8 4 8 i Dielectric PE foamed PE foamed Screen AL PET AL P AL Copolymer A Le if um 25 12 25 E E 9 12 9 Braid material 24x7x0 11 CuSn f D 16x4x0 11 CuSn Pr construction mm 5 4 5 4 coverage 80 1 gt 38 Screening attenuation dB 90 105 75 85 Anti migration foil um 12 12 Outer sheath PVC LSZH PVC LSZH Minimum bending radius mm 35 70 35 70 Diameter Omm 6 8 6 8 Application Indoor Indoor ELECTRICAL DATA Impedance Ohm 75 75 Capacitance pF m 52 52 Velocity ratio 84 84 Center conductor dc resistance Ohm km 17 5 Outer conductor dc resistance Ohm km 11 5 Attenuation at 20 C 5 MHz dB 100m 1 4 1 5 50 MHz dB 100m 4 0 4 6 100 MHz dB 100m 5 8 200 MHz dB 100m 8 2 9 0 400 MHz dB 100m 11 7 800 MHz dB 100m 16 8 18 8 862 MHz dB 100m 17 7 1000 MHz dB 100m 19 0 21 1 1600 MHz dB 100m 24 5 2150 MHz dB 100m 29 0 30 8 2400 MHz dB 100m 30 7 32 8 Structural Return Loss SRL 5 470 MHz dB gt 35 0 gt 33 0 470 862 MHz dB gt 28 0 gt 26 0 862 2400 MHz dB gt 24 0 gt 22 0 Approval EN 50117 CEI 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes 200 Triax KOKA cable for indoor use KOKA 6 6 CCS is low cost universal coaxial cable for TV broadcast in house cabling The low attenuation prede
171. 6 100189 FM Omni with mast bracket 11 E lns powere o SO 108688 Combi 27 ch 5 12 UHF Mastmount 26 100192 FM Omni with window bracket 11 aS re powere o GO 108696 Combi 57 ch 5 11 21 69 26 100160 FM 1 element folded dipole 10 is power 322066 HTA 3038 MA1 Mains powered 151 153605 Crimp Tool 209 100161 FM 2 elements folded dipole 10 322072 HTA 3038 MA Mai d 154 153609 Crimp tool for RG 11 crimp connectors 209 100162 FM 3 elements folded dipole 10 ains powere l 322054 HTA 3038 MP1 Mains powered 151 153607 Crimp tool for RG 6 crimp connectors 209 100163 FM 4 elements folded dipole 10 322060 HTA 3038 MP Mai d 151 153603 Crimp tool universal RG6 RG11 209 100164 FM 5 elements folded dipole 10 Mains powered 347413 HTM 4 12T 180 100197 FM 8 elements Stereo 11 347617 HTM 6 127 180 342000 D7020 A1 attenuators 196 100170 FM 1 DAB aerial 11 347810 HTM SO OT 180 126310 DAP 600 60 cm Ral 1013 84 100171 FM 5 DAB aerial 11 347912 HTS T 174 126311 DAP 601 60 cm Ral 7016 84 100193 FM Zigma aerial 11 347916 TE G 174 126313 DAP 700 70 cm Ral 1013 84 153054 F R75 Terminator bag with 5 pcs 211 347002 Gre 174 126314 DAP 701 70 cm Ral 7016 84 153606 _ F Tool 209 347012 See DC 174 126318 DAP 800 85 cm Ral 1013 84 303481 FV01 225 347003 Gra 174 126319 DAP 801 85cm Ral 7016 84 303482 FV 02 225 347013 HTS 3 DC 174 126316 DAP 900 95 cm Ral 1013 84 G 126317 DAP 901 95 cm Ral 7016 84 sey St HE 126309 DAP 6dg FlexiBlock 88 23270 GAD
172. 7 862 47 862 Insertion loss dB 1 5 20 1 5 20 1 5 20 2 15 0 20 Through loss VHF dB UHF dB Number of outputs pcs 1 1 1 1 1 DC throughpower Yes No NO Yes Yes Connector S amp C S amp C IEC S amp C F con Remarks Outdoor Indoor Indoor Centre frequency Indoor 608 MHz Channel 33 470 574 MHz Channel 43 646 860 MHz ben oo Type F att F att F att F att 3 dB 6 dB 10 dB 20 dB Part No 153710 153711 153712 153713 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 Attenuation dB 3 6 10 20 Packing size pcs 1 1 1 1 Remarks Technical data on IEC attenuator Type IEC att EC att EC att EC att EC att EC att 3 dB 6 dB 9 dB 12 dB 18 dB 24 dB Part No 153720 153721 153722 153723 153724 153725 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Attenuation dB 3 6 9 12 18 24 Packing size pcs 1 1 1 1 1 1 Remarks 196 Triax power inserter Battery filter TRIAX battery filter is intended to power an amplifier through the coax cable from a battery IFP 529 Technical data on battery filter power inserter TYPE IFP 529 TPIO1DC APS 007 Part No 339529 347001 336182 Frequency range MHz 47 862 47 862 Inputs pcs 1 1 Outputs pcs 2 1 Insertion loss 47 852 dB 2 x 4 0 5 40 MHz dB 40 470 MHz dB 470 750 MHz dB 750 862 MHz dB Tap loss output 47 852 4 0 5 40 MHz dB 40 470 MHz dB 470 750 MH
173. 7 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 35 5 36 5 37 9 39 0 G T LNB 0 7 dB dB K 13 6 14 7 15 8 16 9 X polarisation dB gt 2 gt 2 gt 2 gt 27 Offset angle degrees 26 26 26 26 Elevation range degrees 10 50 10 50 10 50 10 50 Reflector type F D 0 6 Offset Offset Offset Offset Beam width degrees Windload 42 m s N 378 600 735 846 Material Fibre glass Fibre glass Fibre glass Fibre glass Finish Alu arm and Alu arm and Alu arm and Alu arm and brackets brackets brackets brackets Aluminium LNB holder mm O40 O40 O40 O40 Mast dimension mm O32 60 O32 60 O32 60 O32 60 Wall bracket optional extra optional extra optional extra optional extra Remarks Double U brackets on all types 84 The solid double mast bracket ensures that the fibre glass dish is fixed firmly to the mast and locked in the desired position Technical data on elliptical dishes Elliptical reg 1 perforated 52 x 42 cm Elliptical reg 1 solid 52 x 42 cm Elliptical reg 2 perforated 72 x 58 cm TRIAX elliptical dishes The Triax range of elliptical dishes has been designed specifically for reception of digital satellite signals The dishes are available in 2 sizes 44 cm and 60 cm and both have been approved by BSKYB who is the world leader in digital platforms and also used by NSAB on the Scandinavian market The dishes
174. 7 1577 1577 1577 1577 Connector SC type SC type SC type SC type SC type SC type Type MTH MT MT MT MT MTD Remarks Split beam Frequenze 88 MHz 108 MHz FM 3 elem Frequenze 88 MHz 108 MHz FM 5 elem 10 Triax band I FM and DAB aerial The FM omni directional aerial is specially designed for areas with many powerful stations transmitting from many directions FM omni directional is available with mast brackets or window brackets The Zigma aerial is a dual polarisation 1 element aerial The DAB aerial covers the frequency range 200 240 MHz VHF Ch 9 13 FM Zigma DAB 1 DAB 5 Technical data FM 8 FM Zigma DAB 1 DAB 5 100197 100193 100170 100171 Channel 9 13 9 13 Band BII BII BII BII EI BIll Elements pcs 8 1 1 1 1 5 Gain dBi 9 5 2 0 2 0 1 0 2 2 8 0 Front to back ratio dB 24 D D D gt 12 Beamwidth hor deg 21 180 180 45H 180V 180 33 43 Windload N 128 16 16 31 20 43 Weight kg 3 2 0 6 0 6 0 7 0 45 0 75 Material Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Dimensions length mm 2383 505 505 550 400 1095 width mm 1699 1140 625 705 Connector SC type SC type SC type SC type SC type SC type Type MTD MT MTHV MT MTH MTH Remarks Split beam 200 240 MHz 200 240 MHz Frequenze 88 MHz 108 MHz Frequenze 200 MHz 260 MHz FM 8S elem FM Omni directional DAB 5
175. 74 120 862 5 74 120 862 5 74 120 862 5 74 120 862 5 74 120 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 87 5 108 Through loss TV dB 2 5 1 5 1 5 1 0 1 0 Radio dB 2 5 1 5 1 5 1 0 1 0 Tap loss TV dB 7 5 10 0 14 0 20 0 23 0 Radio dB 7 5 11 0 15 0 20 0 23 0 Isolation TV radio dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 TV out dB gt 18 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 Radio out dB gt 30 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 Return loss TV EN 50083 4 dB Cat C Cat C Cat C Cat C Cat C Radio EN 50083 4 dB Cat D Cat D Cat D Cat D Cat D Shielding factor VHF dB gt 85 0 gt 85 0 gt 85 0 gt 85 0 gt 85 0 UHF dB gt 75 0 gt 75 0 gt 75 0 gt 75 0 gt 75 0 Connectors TV IEC male lIEC male IEC male lIEC male IEC male Radio lIEC female lIEC female lIEC female lIEC female IEC female DC through No No No No No Standards CE EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 75 75 Weight kg 0 146 0 146 0 146 0 146 0 146 Dimensions mechanical mm O60 O60 O60 O60 60 Remarks Please refer to page 232 for cover frame and terminators According to CENELEC B 5 40 MHz gt 18 dB 40 862 MHz min 18 dB 1 5 oct C 5 40 MHz gt 14 dB 40 862 MHz min 14 dB 1 5 oct D 5 862 MHz gt 10 dB 217 Triax TOU multimedia tv radio outlets Triax TOU loop through multimedia tv radio high quality outlets The Triax TOU series of
176. 75 S 24 326 334 327 25 332 75 63 806 814 807 25 812 75 8 MHz S25 334 342 335 25 340 75 64 814 822 815 25 820 75 S 26 342 350 343 25 348 75 65 822 830 823 25 828 75 S27 350 358 351 25 356 75 66 830 838 831 25 836 75 S 28 358 366 359 25 364 75 67 838 846 839 25 844 75 S 29 366 374 367 25 372 75 68 846 854 847 25 852 75 S 30 374 382 375 25 380 75 69 854 862 855 25 860 75 S 31 382 390 383 25 388 75 Digital TV S 32 390 398 391 25 396 75 S21 D 302 310 D 306 S 33 398 406 399 25 404 75 S channel S 22D 310 318 D314 S 34 406 414 407 25 412 75 range S23 D 318 326 D 322 S 35 414 422 415 25 420 75 EGO 306 334 D 330 S 36 422 430 423 25 428 79 Channel S 25D 334 342 D 338 S 37 430 438 431 25 436 75 widik S26 D 342 350 D 346 S 38 438 446 439 25 444 75 8 MHZ S 27 D 350 358 D 354 S 28D 358 366 D 362 S 29D 366 374 D 370 S 30D 374 382 D 378 S 31D 382 390 D 386 S 32D 390 398 D 394 S 33D 398 406 D 402 S 34D A06 414 D 410 S 35D 414 422 D 418 S 36D 422 430 D 426 S 37D 430 438 D 434 248 S 38D 438 446 D 442 Spec chanel Spec chanel Channel Channel Video Audio limits carrier carrier MH2 MH2 MH2 VHFI A 52 5 59 5 53 75 59 25 B 61 68 62 25 67 75 VHF Il C 81 88 82 25 87 75 VHF Ill D 174 181 175 25 180 75 E 182 5 189 5 183 75 189 25 F 191 198 192 25 197 75 G 200 207 201 25 206 75 H 209 216 210 25 215 75 H 1 216 223 217 25 222 15 H 2 223 230 224 25 229 75 VHFI RI 48
177. 750 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 20 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 17 0 gt 17 0 gt 17 0 gt 17 0 Return loss tap 5 40 MHz dB gt 22 0 gt 20 0 gt 22 0 gt 22 0 40 470 MHz dB gt 20 0 gt 20 0 gt 18 0 gt 18 0 470 750 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No Connectors F connector F connector F connector F connector Certification Ce CE Ce CE Impedance Ohm 15 15 15 15 Weight kg 0 106 0 106 0 106 0 106 Dimensions h x d x w mm 38x16x118 38x16x118 38x16x118 38x16x118 171 Triax taps ATT series 5 1000 MHz CLASS GRADE 1 ATT 4 12 ATT 4 16 ATT 4 20 ATT 5 12 ATT 6 16 346412 346416 346420 346512 346616 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Outputs pcs 4 4 4 5 6 Insertion loss in out 5 40 MHz dB lt 3 6 lt 2 2 lt 0 9 lt 3 6 lt 2 3 40 470 MHz dB LT 225 lt 1 0 lt 3 lt 2 5 470 750 MHz dB lt 3 8 225 lt 1 1 lt 3 8 lt 2 7 750 860 MHz dB lt 4 0 lt 2 7 lt 1 3 lt 4 0 lt 2 9 860 1000 MHz dB lt 4 2 lt 3 0 lt 1 5 lt 4 2 lt 3 0 Tap loss in tap 5 40 MHz dB 12 0 1 0 16 0 1 0 20 0 1 0 12 0
178. 8 Through loss TV dB 4 0 Radio dB 4 0 Tap loss TV dB 1 5 1 5 2 0 2 0 4 5 Radio dB 2 0 2 0 2 5 2 5 5 5 Isolation TV radio dB gt 10 0 gt 10 0 gt 15 0 gt 15 0 gt 10 0 Out TV dB gt 15 0 Out Radio dB gt 20 0 Return loss TV EN 50083 4 dB Cat C Cat C Cat C Cat C Cat C Radio EN 50083 4 dB Cat D Cat D Cat D Cat D Cat D Shielding factor VHF dB gt 85 0 gt 85 0 gt 85 0 gt 85 0 gt 85 0 UHF dB gt 75 0 gt 75 0 gt 75 0 gt 75 0 gt 75 0 Connectors TV lEC male lEC male lIEC male lEC male lIEC male Radio lEC female lEC female lEC female lEC female lEC female DC through TV No TV 22 No Standards CE EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 15 15 15 75 75 Weight kg 0 146 0 146 0 146 0 146 0 146 Dimensions mechanical mm O60 O60 O60 O60 O60 Remarks Please refer to page 232 for cover frame and terminators According to CENELEC B 5 40 MHz gt 18 dB 40 862 MHz min 18 dB 1 5 oct C 5 40 MHz gt 14 dB 40 862 MHz min 14 dB 1 5 oct D 5 862 MHz gt 10 dB 216 Triax TOU tv radio outlets Triax TOU standard tv radio high quality outlets Technical data 5 862 MHz standard outlets TYPE TOU 7 TOU 10 TOU 14 TOU 20 TOU 23 Part No incl cover and frame excl cover and frame 303627 303630 303614 303629 303323 Outputs TV Radio TV Radio TV Radio TV Radio TV Radio Frequency range TV MHz 5
179. 8 56 with F connector 18 300326 TMS 5x6p 135 300411 Triax TQT001 Universal quattro LNB 91 107349 YAGI 15el ch 36 69 with F connector 18 300336 TMS 5x6p UK 135 300438 Triax TQT002 Universal quattro LNB 90 108269 YAGI 18el ch 21 23 w support beam 19 300318 TMS 5x8 134 300404 Triax TSI001 Universal single LNB 91 107269 YAGI 18el ch 21 23 with F connector 19 300328 TMS 5x8p 135 300430 Triax TSI003 Universal single LNB 89 107368 YAGI 18el ch 21 69 with F connector 19 300338 TMS 5x8p UK 135 300432 Triax TSI004 Universal single LNB 89 108268 YAGI 18el ch 24 26 w support beam 19 370002 TMS 6 way bar 148 300429 Triax TSI005 Universal Hi gain single LNB 89 108265 YAGI 18el ch 27 30 w support beam 19 300425 TMS 8 AMPP 139 300407 Triax TTWO001 Universal twin LNB 91 108266 YAGI 18el ch 31 34 w support beam 19 153059 TMS 8 way bar 148 300435 Triax TTW002 Universal twin LNB 90 108257 YAGI 18el ch 35 38 w support beam 19 370003 TMS 8 way bar 148 126391 TRIAX Unique Bulk Ral 7030 100 pcs pll 86 108264 YAGI 18el ch 39 43 w support beam 19 300365 TMS 9 AMP 138 126390 TRIAX Unique Multi Reception Dish Ral 7030 86 108262 YAGI 18el ch 44 49 w support beam 19 300372 TMS 9x12 C 132 416014 TRP Line power supply 158 108267 YAGI 18el ch 50 55 w support beam 19 300342 TMS 9x12p 133 332323 TS 315 2DC 194 108263 YAGI 18el ch 56 62 w support beam 19 300352 TMS 9x12p UK 133 343912 TIM 12 180 108259 YAGI 18el ch 63 69 w support beam 19 300376 TMS 9x16 C 1
180. 80 10 kHz max 80 10 kHz max 80 10 kHz max 80 10 kHz max DBc Hz 100 100 kHz max 100 100 kHz max 100 100 kHz max 100 100 kHz max Conversion gain typ dB max dB 5 E i Se Noise figure Low dB 0 6 0 6 0 6 0 6 High dB 0 6 0 6 0 6 0 6 Image rejection min max dB 40 80 40 80 40 80 40 80 Cross polarization isolation dB 25 typ 25 typ 20 typ 20 typ Power requirements 0 00 DC current consumption typ mA 115 typ 160 max 150 typ 220 max 180 typ 220 max 180 typ 220 max Operating voltage Vertical VDC 11 5 14 0 11 5 14 0 11 5 14 0 11 5 19 0 Horizontal VDC 16 0 19 0 16 0 19 0 16 0 19 0 11 5 19 0 Band switching Low band Hz 0 D 0 High band KHz 22 22 22 Operating temperature range C 40 60 40 60 40 60 40 60 ETECESS a Diameter Width x Heigth x Depth mm 56 x 159 x 76 56 x 159 x 76 56 x 159 x 76 Max depth incl feedhorn mm 151 151 151 Weight kg 0 35 0 35 0 35 Packing size pcs 1 1 1 1 DiSEqC switches multi satellite reception MFD DiSEqC switches for switching between 2 or 4 LNBs DiSEqC switches are used in multi satellite installations for switching between 2 or 4 LNBs each pointing at different satellites e Available with 2 or 4 inputs for switching between 2 or 4 satellite positions e High isolation ensures problem free operation in multi user installations e Housed in fully shielded waterproo
181. 9 0 069 0 069 Dimensions h x d x w mm 50x16x74 50x16x74 50x16x74 50x 16x 74 177 Triax taps HTT series 5 1000 MHz CLASS HTT 4 12 HTT4 16 HTT4 20 HTT 4 24 347412 347416 347420 347424 Frequency range MHz 5 862 5 862 5 862 5 862 Outputs pcs 4 4 4 4 Insertion loss in out 5 40 MHz dB lt 2 9 ade Se lt 0 7 lt 0 7 40 470 MHz dB lt 3 2 ed Pe lt 0 7 lt 0 7 470 860 MHz dB lt 3 7 lt 2 1 lt 1 2 lt 1 2 Tap loss in tap 5 40 MHz dB 12 0 1 0 16 0 1 0 20 0 1 0 24 0 1 0 40 470 MHz dB 12 0 1 5 16 0 1 5 20 0 1 5 24 0 1 5 470 860 MHz dB 12 0 1 5 16 0 1 5 20 0 1 5 24 0 1 5 Isolation tap tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 Isolation out tap 5 40 MHz dB gt 25 0 gt 35 0 gt 40 0 gt 40 0 40 470 MHz dB gt 25 0 gt 30 0 gt 35 0 gt 35 0 470 860 MHz dB gt 22 0 gt 28 0 gt 30 0 gt 30 0 Return loss in out 5 40 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 40 470 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 470 860 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 Return loss tap 5 40 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 25 0
182. 940 x 550 x 16 Units in mountring frame pcs 21 21 Remarks Backboard Backboard included included The TCC 19 cabinet is delivered with backboard for switches amplifiers etc If the equipment dissipates too much heat it can be controlled by installing a fan and a thermostat The lock system prevents access by unauthorised persons to the headend Large cable entries in the bottom corners of the rack cabinet The side plate is easily removed for easy access i to the equipment GO during installation amp The TCC 19 cabinet is and service rr provided earthing facilities E TT d Louvres at the bottom of a rr peer A a the front door to ensure adequate ventilation in the cabinet The TCC 19 cabinet is provided with adjustable feet Wheels are optional Accessories TYPE Fan 230V Protection Thermostat 4 Wheels Key for grid with lock EMKA lock Part No 708020 708017 708028 737030 848616 Dimension H x W x D mm 120 x 120 x 38 115 70 x 70 x30 74 on wheels Outer pack pcs 1 1 1 1 1 Remarks 4 in a set Security lock 123 Triax mounting frame TMF 512 Use the possibilities of an open 19 mounting frame providing easy access and excellent overview With the open 19 mounting frame Triax offers you a quite new and functional mounting solution for your headend if more units are built together Complete TMF 512 pack
183. AB Frequency range MHz 47 108 174 230 Gain dB 10 10 Linearity dB 2 2 Noise figure dB 4 4 Output voltage 60 dB IMD dBuV 93 93 Output voltage 35 dB IMD dBuV Return loss input dB gt 10 gt 10 output dB gt 10 gt 10 Impedance Ohm 75 Shielding efficiency dB 60 Power consumption V mA 12 190 330 Polarity to ground Dimensions product mm 288x121 x 43 Weight gross kg 0 9 Connectors F type DC plug F type Remarks Digital link line power supply output automtically switched OFF when used as Line power input 9V D GZ GUA overload protected Automatic masthead line power facility 12 VDC 50 mA overload protected DC power bypass for LNB Yes Power On LED green Yes 239 Triax digital links The Triax digital link is compatible with many different digital satellite receivers with an output marked RF OUT 2 that provides a second TV output together with a 9 volt DC supply The Triax digital link will allow control of your digital satellite receiver whilst viewing in other rooms in the home e Silver and anthracite colour styles e Competitive pricing e Attractive design e Easy to install Technical data Triax digital links TYPE Digital link Part No silver w blue lens 339690 Part No anthracite w blue lens 339691 Input signal frequency carrier kHz 37 9 Output signal frequency carrier kHz On off keyed Line power requirment VDC mA 9 10 Sensor lead cm 100 Connectors output IEC male
184. Active DiSEqC switch 3 SAT TV 144 Ed 121961 TDS 110 Single EUROLINE Ral 7016 80 80242 TLT 811 192 364350 TDC 350 Active DiSEqC switch 3 SAT terr 145 ve 121960 TDS 110 Single EUROLINE Ral 7035 80 80239 TUT 814 192 364400 TDC 400 Active DiSEqC switch 4 SAT TV 144 aio OC dee ac ea beg 121962 TDS 110 Single EUROLINE Ral 8012 80 80240 TUS 192 See Euge EZ STE ZEI Gea 122912 TDS 110 Single packed Ral 7016 78 80241 TLT 820 192 See azie Ga bez bee 122908 TDS 110 Single packed Ral 7035 78 80256 TLT 823 193 Se KE Ga deg Se 122910 TDS 110 Single packed Ral 8012 78 80257 TLT 826 193 pane ka l baia Sa beg Se 122525 TDS 54 Bulk Ral 7016 200 pcs pll 82 80258 TU 829 193 Pereda gd bege Ee 122526 TDS 54 Bulk Ral 7035 200 pes pll 82 80259 TLT 832 193 beg EE Sa beg Se 122547 TDS 54 Bulk Ral 8012 200 pcs pll 82 80260 TLT 835 193 bage LONE a aT 122568 TDS 54 Bulk w single Ral 7016 200 pes pll SO 333326 TMA 12 2 U 46 a 122567 _TDS 54 Bulk w single Ral 7035 200 pes pll 82 333324 TMA 18 W U 46 Betea Za Sea 122569 TDS 54 Bulk w single Ral 8012 200 pcs pll 82 _ 333571 TMA 24W 20W U 46 ap 121560 TDS 54 Single EUROLINE Ral 7035 80 333570 TMA 24W 2W U 46 300736 IDE 78 multiblock 3xLNB no LNB amp switch 87 122512 TDS 54 Single packed Ral 7016 78 333325 TMA 28 W U 46 300737 TDE 78 multiblock 3xLNB no LNB amp switch 87 F Se 300734 TDE 88 110 multiblock 2xLNBnoLNB amp switch 87 122510 TDS 54 Single packed Ral 7030 78 324575 TM
185. Attenuation at 20 C 5 MHz dB 100m 1 5 1 5 50 MHz dB 100m 4 6 4 6 200 MHz dB 100m 9 0 9 0 470 MHz dB 100m 14 4 14 4 600 MHz dB 100m 16 3 16 3 800 MHz dB 100m 18 8 18 8 1000 MHz dB 100m 21 1 21 1 1350 MHz dB 100m 24 6 24 6 1750 MHz dB 100m 28 0 28 0 2050 MHz dB 100m 30 3 30 3 2400 MHz dB 100m 32 9 32 9 Structural Return Loss SRL 5 470 MHz dB gt 30 0 gt 30 0 470 862 MHz dB gt 25 0 gt 25 0 862 2400 MHz dB gt 20 0 gt 20 0 Approval EN 50117 CEl 46 1 CEI 12 15 Yes Yes Yes Yes Yes Yes 206 Double screen fly leads Fly leads for TV amp radio 75 Ohm white double screened cable with coax IEC male and female connectors The connectors are crimped to ensure screening better than 70 dB Technical data on quality double shielded fly leads TYPE male female male female male female male female male female Part No 153400 153401 153402 153403 153404 Inner conductor mm 0 8 0 8 0 8 0 8 0 8 Dielectric PE PE PE PE PE Outer sheath mm 5 8 5 8 5 8 5 8 5 8 Min bending radius mm 60 60 60 60 60 Colour sheath White White White White White Attenuation at 100 m 50 MHz dB 5 5 5 5 5 5 5 5 5 5 2150 MHz dB 42 0 42 0 42 0 42 0 42 0 Standards CE CE Ce CE CE Impedance Ohm 75 75 75 75 75 Weight kg Length cm 150 250 500 750 1000 Remarks Single pieces Single pieces Single pieces Single pieces Single pieces in plastic bag in plastic bag in plastic bag in plastic bag in plastic b
186. B 10A multiband amplifier 118 i ee Gezi barez no Ee Sd Sa 122518 TDS 54 Single packed Ral 7035 78 324576 TMB 10B multiband amplifier 118 ei a 7 a Sa Ga gd E 122625 TDS 64 Bulk Ral 7016 100 pcs pll 82 324577 TMB 10S multiband amplifier 118 O TIDE Se moun eg mo e beg 122624 TDS 64 Bulk Ral 7030 100 pcs pll 82 324571 TMB 6 multiband amplifier 118 appease A Ee 122617 TDS 64 Bulk Ral 7035 100 pcs pll 82 122674 TMB 64 Ral 7016 5 pcs Carton box pr unit 82 o ee Ga EE 122647 TDS 64 Bulk Ral 8012 100 pcs pll 82 122627 TMB 64 Ral 7035 5 pcs Carton box pr unit 82 Eate e SEa Se 122668 TDS 64 Bulk w single Ral 7016 100 pcs pll SO 122236 TMB 78 Ral 7016 5 pcs Carton box pr unit 82 E e Pe Se 122672 TDS 64 Bulk w single Ral 7030 100 pes pll SO 123732 TMB 78 Ral 7016 5 pcs Carton box pr unit 82 Sega bagia Sade Ee 122667 TDS 64 Bulk w single Ral 7035 100 pcs pll SO 122733 TMB 78 Ral 7035 5 pcs Carton box pr unit 82 ay ae Se Se 122669 TDS 64 Bulk w single Ral 8012 100 pcs pll SO 123731 TMB 78 Ral 7035 5 pcs Carton box pr unit 82 pose ae Heda bagi Se 121661 TDS 64 Single EUROLINE Ral 7016 80 122832 TMB 88 Ral 7016 3 pcs Carton box pr unit EO Eee Say a Sa be 121660 TDS 64 Single EUROLINE Ral 7035 80 123832 TMB 88 Ral 7016 3 pcs Carton box pr unit 82 ner Senay x e Se 121662 TDS 64 Single EUROLINE Ral 8012 80 122831 TMB 88 Ral 7035 3 pcs Carton box pr unit 82 aT TET ee dek SO bea 122612 TDS 64 Sin
187. Ch XX rest Ch XX rest rest Switchable Switchable VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF all inputs Connector S amp C S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 2 0 2 0 2 0 2 0 2 0 2 0 2 Dimensions Height mm 90 90 90 90 90 69 69 Depth mm 48 48 48 48 48 55 55 Width mm 115 115 115 115 115 94 94 Remarks 55 Triax single channel mast filters TRIAX range of filters When you are using the UHF series with the XX and YY channels you must remember that there must be 2 unused channels between your specified XX and YY UHF chan nels 70000 mast filter 71234 7132 G 75132 TC 335 TC 335 TC 356 DC VHF DC both DC SAT 311122 311125 311140 331381 331382 331383 Input 1 Band UHF TV UHF UHF UHF TV Channel 21 69 2 69 21 69 21 69 21 69 2 69 Through loss dB 0 5 1 0 2 0 1 0 1 0 2 0 Input 2 Band BIII FM FM VHF VHF SAT Channel 5 12 2 12 2 12 IF Through loss dB 0 5 1 0 0 5 1 0 1 0 3 0 Input 3 Band FM BI BIII Channel 2 12 Through loss dB 0 5 1 0 Input 4 Band Bl Channel 2 4 Through loss dB 0 5 Stop band attenuation VHF BI dB gt 20 FM dB gt 12 gt 20 gt 20 Bill dB gt 25 gt 20 gt 20 gt 15 UHF dB gt 30 gt 20 gt 40 SAT dB gt 35 Numbers of in output 4 1 2 1 3 1 2 1 2 1 2 1 DC throughpower Switchable 1 of the UHF VHF Switchable SAT inputs VHF UHF Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 2 0 2 0 2 0 2 0 2 0 2
188. EC male IEC male Radio lIEC female IEC female lIEC female lIEC female DAB F female DC through TV radio mA 100 100 No No Standards CE EN 50083 2 EN 50083 2 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 75 Weight kg 0 100 0 100 0 100 0 068 Dimensions w x h x d mm 50x77x26 50 x 77 x 26 50 x 77 x 26 50 x 77 x 26 Replacing TD 260C TD 263C Remarks Please refer to page 233 for cover frame and terminators 221 Triax TD satellite tv amp radio outlets Triax s FUGA TV radio outlets have improved shielding factor and are much faster to mount The newly developed design where backplate and terminals are die cast in one piece sets new standards to shielding and mechanical stability e High HF tightness e Simple and quick mounting e Solid mechanical quality e Fulfil modern day s technical multimedia requirements TDsatellite outlet housing Technical data on SAT outlets 5 2200 MHz TYPE TD 250 SAT TD 252 SAT Terminated Terminated Part No white in bag 302415 302416 Part No grey in bag 303415 303416 Part No white in box 302465 302466 Part No grey in box 303465 303466 Outputs TV Radio TV Radio SAT SAT Frequency range TV MHz 47 862 47 68 132 862 Radio MHz 87 5 108 SAT MHz 950 2150 950 2150 Through loss TV dB Radio dB SAT dB Tap loss TV dB 1 0 1 5 1 0 1 5 Radio dB SAT dB 1 0 1 0 Linearitet TV radio SAT dB 1 1 1 1 1 1 Isolation SAT Ra
189. Elements pcs 6 8 10 13 Gain dBi 8 5 9 5 11 0 13 5 Front to back ratio dB 19 21 24 26 Beamwidth hor deg 23 21 18 17 Windload N 48 56 96 104 Weight kg 1 3 1 8 2 8 3 3 Material Alu Alu Alu Alu Dimensions length mm 1790 2 50 2973 3675 width mm 870 875 880 880 Connector SC type SC type SC type SC type Type MT MT MTD MTD Remarks Split Split beam beam Ch 8 10 elem Channel Channel Channel Channel Channel Channel Channel Channel 6 6 6 6 T T T T 100255 100257 100279 100282 100305 100307 100329 100332 Channel 6 6 6 6 7 7 7 7 Band Bill BIII BIII BIII BIII BIII BIII BIII Elements pcs 6 8 10 13 6 8 10 13 Gain dBi 8 5 9 5 11 0 13 5 8 5 9 5 11 0 13 5 Front to back ratio dB 19 21 24 26 19 21 24 26 Beamwidth hor deg 23 21 18 17 23 21 18 17 Windload N 48 56 88 96 48 56 88 96 Weight kg 1 3 1 8 2 8 3 3 1 3 1 8 2 8 3 3 Material Alu Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 1730 2612 2883 3675 1689 2487 2817 3675 width mm 840 850 850 8500 810 815 810 840 Connector SC type SC type SC type SC type SC type SC type SC type SC type Type MT MT MTD MTD MT MT MTD MTD Remarks Split Split Split Split beam beam beam beam 14 BIll 6 elem Gain BIll 8 elem Gain Ch 6 6 elem Ch 7 8 elem Technical data Triax band II single channel aerial VHF
190. GDE 270 terminator 234 347014 HTS 4 DC 174 342250 DB 0 20 R1 attenuators 196 23465 GAD GDZ 465 surface 234 347006 HTS 6 174 23476 GAD GDZ 476 cover 234 347016 HTS 6 DC 174 317570 DCF 3153 15 A2 52 23215 GAD215 228 347008 HTS 8 174 317402 DCF XXYY 15A4 53 23247 GAD 247 228 347018 HTS 8 DC 174 317401 DCF XXYY 15A3 53 23252 GAD 252 229 347112 HTT 1 12 175 317400 DCF XXYY 15A2 53 333112 DDU 112 domestic distributio unit aag ede a ee HU EG 15 133220 Deck mount 27 23254 GAD 254 229 347120 HTT 1 20 175 300745 Decoder Cable Sub D to Phono fie oo a eae Ga 300742 Decoder cable Sub D to Scard 111 GEA Ap EE Sea Za 108310 Digi 10el ch 21 37 16 23269 GAD 269 228 347108 HTT 1 8 175 108311 Digi 10el ch 21 69 16 23274 GAD 274 228 347210 HTT 2 10 176 Ze 133090 G bolt 1 2 120 mm 68 347212 HTT 2 12 176 108808 Digi 10el ch 21 69 with combiner 16 5 Se 133100 G bolt 200 mm 68 347220 HTT 2 20 176 108319 Digi 10el ch 21 69 with wallmount 16 Sa 108340 Digi 14el ch 21 37 17 133101 G bolt 300 mm 68 347208 HTT 2 8 176 ge i 133102 G bolt 1 2 400 mm 68 347310 HTT 3 10 177 108341 Digi 14el ch 21 69 17 ET 108612 Digi 14el ch 21 69 with combiner i oe C kot A eh oie ui 108360 Digi 18 el ch 21 37 17 850035 G bolt nuts 68 347316 HTT 3 16 177 108361 Digi 18el ch 21 69 17 304258 _ Grid diplexed 231 347320 HTT 3 20 177 108200 Diqi Gel SO 21 69 16 304259 Grid diplexed 231 347412 HTT 4 12 178 gi De ON 304260 Grid dipl
191. Gain Out 1 dB 18 0 8 18 15 0 D 0 Out 2 dB 18 0 8 18 15 0 12 0 12 0 Noise figure UHF VHF dB 4 5 4 5 4 0 4 0 4 0 Max output voltage 60 dB IMA dBuvV 2 x 101 2 x 101 2 x 103 2 x 101 2 x 101 Max output level 10 channels dBuV 78 78 10 channels dBuV 76 76 10 channels dBuV 75 75 Numbers of in output 2 2 2 1 a b 1 a b 2 a b 2 a b Voltage V AC 230 230 230 230 230 Power consumption W 1 2 1 2 3 3 3 Connector type S amp C S amp C S amp C IEC IEC Impedance Ohm 75 75 75 75 75 Operation temperature range C 0 50 0 50 0 50 0 50 0 50 Weight kg Dimensions h x d x w mm Remarks Power adaptor included Power adaptor included Power adaptor included 166 Type 02 ZIN and 2TVplus amplifiers for mounting directly on the outlet box Triax passive components Splitters and taps A TECH 5 1000 MHz H TECH 5 1000 MHz S TECH 5 2400 MHz TDP delivery point TLS range of outdoor splitters TLT range of outdoor taps Triax indoor splitters Attenuators Power inserters Power supplies Cables and tools Indoor outdoor Multi and Fly leads Tools and connectors Adapters terminators isolators electrical articles 168 173 174 180 181 185 186 187 188 193 194 195 196 197 198 199 200 205 206 207 208 210 211 213 Triax splitters ATS series 5 1000 MHz Technical data 5 1000 MHz professional range in splitters
192. Gain dB 1x9 1x21 24 25 24 20 30 10 20 Noise figure dB lt 2 4 lt 1 8 lt 2 5 lt 1 8 lt 2 5 lt 2 5 Input 2 Channel Band 21 69 21 69 BI BII BIll BI BII BIII Gain dB 2x5 2x17 14 24 1 Noise figure dB lt 2 4 lt 1 8 lt 2 5 Max output voltage 60 dB IMA dBuV 101 2 x97 101 2 x 97 105 105 105 2 x 101 Numbers of in output 2 3 2 3 2 1 2 1 1 1 1 2 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 15 30 30 30 30 40 DC throughpower Switchable Switchable Switchable Switchable Switchable Switchable Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 175 0 175 0 175 0 175 0 175 0 175 Dimensions Height mm 19 79 79 79 79 79 Depth mm 62 62 62 62 62 62 Width mm 118 118 118 118 118 118 Remarks Wideband Wideband Multiband Multiband Wideband Wideband 43 Triax TA multichannel amplifier series TRIAX s TA multichannel amplifier TRIAX multichannel amplifiers are HF tight CE marked and available in a splashproof plastic box type HFT6 with mast mounting In one unit you can connect many different signals from e g channels from neigh bouring countries with the regional and some local TV channels BI II and BI signals can be connected through the VHF input EE ae ia I je a Wida mer d TA 65 3R amplifier OTRA 50 CH 23 60 AMPLIFIER VERSION TA 63 3R Rest UHF BI BII
193. GmbH Oberer Paspelsweg 6 8 6830 Rankweil Brederis Austria Tel 43 55 22 307 D Fax 43 55 22 307 394 e mail rankweil triax hirschmann austria at web www hirschmann austria at Triax Finland Malminkaari 23 B FIN 0O 700 Helsinki Finland Tel 358 9 34 78 470 Fax 358 9 34 78 4710 e mail triax fi triax dk web www triax fi Triax S rl France 13 rue du Chemin de Fer BP27 Lampertheim F 67451 Mundolsheim Cedex France Tel 33 38 81 80 909 Fax 33 38 81 80 900 e mail sc triax fr web www triax fr Triax Hirschmann Multimedia GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Germany Tel 49 7127 140 Fax 49 7127 14 1697 e mail info triax hirschmann de web www triax hirschmann com Triax Hirschmann Multim dia Electronics Kft Rokolya u 1 13 1131 Budapest XIII Hungary Tel 36 1 349 4199 Fax 36 1 329 8453 e mail info hirschmann multimedia hu web www hirschmann multimedia hu Triax Hirschmann Electronics S A N I F B 28257848 C Ingeniero Torres Quevodo No 20 Poligono Fin de Semana 28022 Madrid Spain Tel 34 91 74 828 36 Fax 34 91 32 961 47 e Mail hes hirschmann es web www hirschmann es Triax AB Sweden Svedengatan 9 S 582 73 Link ping Sweden Tel 46 13 14 41 14 Fax 46 13 14 41 13 e mail triax se triax dk web www triax se Triax UK Abergorki Industrial Estate Treorchy South Wales CF42 6DL UK Tel 44 14 43 77 89 08 Fax dd 14 4
194. Hz 154 322276 MS 110 Tap Module out A B 10 0 10 0 1 1 10 156 300401 SAT line amplifier 139 322242 MCA 100 519 MHz 154 322277 MS 114 Tap Module out A B 14 0 14 0 0 7 0 156 333221 SCA 2021 amp ch 21 47 322244 MCA 100 639 MHz 154 322278 MS 118 Tap Module out A B 18 0 17 8 0 4 0 IGO 333222 SCA 2022 amp ch 22 47 324681 MD 3047 Filter 2 pcs box 158 322274 MS 206 Tap Module out A B 5 6 5 8 2 2 2 4 156 333223 SCA 2023 amp ch 23 47 324682 MD 3047T Filter and testpoint 2 pcs box 158 322273 MS 404 Splitter Module out A B 3 5 3 8 3 3 3 7 156 333224 SCA 2024 amp ch 24 47 324685 MD 5573 Filter 2 pcs box 158 490884 Nicam encoder for TCM 08 116 333225 SCA 2025 amp ch 25 47 324686 MD 5573T Filter and testpoint 2 pcs box 158 109808 NMT450 Gel 415 480mHz mast window bracket___29 333226 SCA 2026 amp ch 26 47 324683 MD 6587 Filter 2 pcs box 158 109814 NMT450 Gel 415 480mHz mast window bracket 29 254 Contents from A to Z
195. Isolation out out TER dB 26 26 26 28 30 Isolation out out SAT dB 30 30 30 30 30 Return loss SAT inputs dB 14 14 14 10 10 Return loss SAT outputs dB 7 7 7 10 10 Return loss TER inputs dB 11 11 11 12 12 Return loss TER outputs dB 8 8 8 10 10 Output level SAT IMD3 35 dB GEUN 100 100 100 100 100 Output level TER IMD3 60 dB dByV 85 85 85 83 82 Impedance input output Ohm 75 75 75 75 75 Switching VDC 13 V 18V 13 V 22 kHz 18 V 22 kHz DiSEqC 2 0 Supply voltage VDC 15 0 5 15 0 5 15 0 5 15 0 5 15 0 5 Power supply Included Included Included Included Included LNB power supply max mA 1000 1000 1000 1000 1000 Colourcoding of IF and TER inputs Yes Yes Yes Yes Yes Temperature range GE 0 55 0 55 0 55 0 55 0 55 Dimensions H x D x W mm 103x71x359 103x71x359 103x71x359 103x71x459 103x71 x559 a A oe nt TMS 9X6P Za BE ih 2 ae SII ie it i EE TMS 9X12P 133 Triax TMS 5x multiswitches Standard 5x multiswitch The TMS 5x series of our multiswitch systems offers unique subscriber benefits in terms of performance and individual freedom a A ar me w a m a s e Md ca ed td e E eze SZ Tzi E n gt E D E sa b u ww pw wo d ETZE eia Eide ATO Jr TMS 5X12 O erab TMS 5x4 A ET Zr TMS 5x6 Technical data Modular multiswitches with 4 polarities 1 terr input External power supply
196. KOKA 80 200 153221 F Compression CX3 5 1 210 EAEE Sa a bee 150166 Coax KOKA 80 black 204 153222 F Compression CX3 7 5 210 ee Line pows o be 150167 Coax KOKA 80 black 204 153073 F Con 6 8 mm 100 pcs Bags 210 bine powered 322003 HEA 38 LP1 Line powered 153 153042 Coax Male angle 211 153053 F Con6 8mm 5 pcs Bags 210 322009 HEA 38 LP Li d 153 153021 Coax Male Angle diecast housing 211 153074 F Con 7 2 mm 100 pcs Bags 210 322018 HEA 38 pe be powered J 153 153032 Coax Male angle Grey 211 153052 F Con 7 2 mm 5 pcs Bags 210 ans power 322024 HEA 38 MA2 Mains powered 153 150074 Coax Multi 4 coloured cable 100 m rolls 206 153593 F con Female Female 211 322006 HEA 38 MP1 Mai d 153 150075 Coax Multi 5 coloured cable 100 m rolls 203 153072 F con 5mm 100 pcs Bags QX 4 210 ains powere Sa 322012 HEA 38 MP2 Mains powered 153 150079 Coax Multi 9 coloured cable 100 m rolls 206 153049 F con Minicable 3 6 210 323068 HEF 845 distributi if 159 150078 Coax Multi 9 coloured cable 50 m rolls 206 153048 F con 5mm 5 pcs Bags QX 4 210 323071 HEF 845C ge ei SIE Ga 159 153017 Coax plastic cover diecast housing 211 153712 F conn 10dB attenuator 196 ZUE EU ampitier 323074 HEF 845CL distribution amplifier 159 150054 Coax QX4S Black 100m 202 153713 F conn 20dB attenuator 196 See Ge 324602 HFA 602 Distribution Amplifier 22 dB 157 150052 Coax QX4S Grey 100m 202 153710 F conn 3dB attenuator 196 eee Se 324603 HFA 603 Distribution Ampl
197. LNB 0 7 dB dB K 14 2 16 0 17 3 19 2 20 6 X polarisation dB gt 2 gt 2 gt 2 gt 27 gt 2 Offset angle degrees 26 26 26 26 26 Elevation range degrees 10 50 10 50 10 60 10 60 10 60 45 80 45 80 Reflector type F D 0 6 Offset Offset Offset Offset Offset Beam width degrees 3 3 1 2 6 2 0 1 8 Windload 42 m s N 323 445 619 902 1222 Material Galv steel Galv steel Galv steel Galv steel Galv steel Finish Polyester powder Polyester powder Polyester powder Polyester powder Polyester powder coat coat coat coat coat Aluminium LNB holder mm O40 O25 O40 O25 O40 O40 O40 Mast dimension mm O32 60 O32 60 O40 95 O40 95 O40 95 Wall bracket optional extra optional extra optional extra optional extra e optional extra Remarks some types available without Triax logo please contact our sales department TD duo block 78 TD flexi block We can supply a wide range of different LNB brackets for the TD series dishes more detailed information on page 91 under LNB brackets TD multi block Triax TDA standard aluminium dishes A dish for any job TD dishes are available in sizes materials and colours for any job ranging from single to multiple user applications and any type of environment e 5 sizes ranging from 50 x 55 cm 34 2 dBi gain to 100 x 105 cm 40 2 dBi gain e Delivered in aluminium or galvanized steel e Available in a number of standard colours and any oth
198. Nm Weight kg 0 8 Packing QTY pcs 1 1 2 1 Remarks with holes for withholesfor e for extention of indoor mounting extention bracketsextention brackets bottom masts supplied with cable Technical data on mast tops Mast top ERIE Ko o Mast top Mast top 28 mm 38 mm 42mm 50 mm 140210 140213 140214 140215 Diameter mm 28 38 42 50 Colour Black Grey Grey Grey Weight kg Packing QTY pcs 1 1 1 1 Remarks 63 Wall and window brackets Triax s range of brackets for perfect installations 3 legs wall bracket p Window bracket MT Wall bracket with extra leg Technical data on wall and window brackets Window bracket MT short Type Wall bracket Wall bracket Window bracket Window bracket Type MT Type MT short Part No 140044 140045 130009 130016 Diameter mm O15 O15 18x 18 18x 18 Clearance from wall mm 600 350 600 190 Height mm 150 200 Weight kg Packing QTY pcs 1 1 1 1 Remarks with extra leg 3 legs complete with complete with SCrews SCrews Technical data on complete sets of wall brackets Type Wall bracket Wall bracket Wall bracket Wall bracket 2 legs 7 5 cm 2 legs 25 50cm 2 3 legs 25 50 cm 2 3 legs 25 50 cm Part No 140036 140037 140047 140048 Mast diameter mm 30 50 max 051 max 051 max 051 Clearance from wall mm 75 250 500 adjustable 250 500 adjustable 500 750 adjustable Material
199. S 17x6C 130 303692 TOU Cover plate 3 hole white 86x86 UK 232 131040 Wall bracket 2 Legs 35 cm 65 301606 TMS 17x6T 131 303686 TOU Cover plate MM 3 hole Offwhite 80x80 232 131050 Wall bracket 2 Legs 45 cm 65 301508 TMS 17x8C 130 303685 TOU Cover plate MM 3 hole White 80x80mm 232 131010 Wall bracket 2 Legs 5 cm 65 301608 TMS 17x8T 131 304115 TOU DDU UK 227 131021 Wall bracket 3 Legs 15 cm 65 300275 TMS 2 AMP 139 304101 TOU diplex UK 227 131031 Wall bracket 3 Legs 25 cm 65 300274 TMS 2x4C 136 304112 TOU Quad UK 227 131041 Wall bracket 3 Legs 35 cm 65 300278 TMS 2x8C 136 304102 TOU Triplexed UK 227 131051 Wall bracket 3 Legs 45 cm 65 300305 TMS 44 AMP 139 304118 TOU DC diplex UK 227 131061 Wall bracket 3 Legs 55 cm 65 153057 TMS 4 way bar 148 303699 TOU F1 Frame 80x80x22mm Off White 232 131071 Wall bracket 3 Legs 65 cm 65 300309 TMS 5 PSU 140 303698 TOU F1 Frame 80x80x22mm White 232 131081 Wall bracket 3 Legs 75 cm 65 300319 TMS 510 splitter 137 332303 TP 3851 199 140040 Wall bracket GF 110 170 wall bracket set 66 300315 TMS 55 Amplifier ext PSU 138 332304 TP 3852 199 140038 Wall bracket GF 125 wall bracket set 66 300330 TMS 55 Amplifier UK 140 347001 TPI 01 Power inserter with F Con 158 140039 Wall bracket GF 175 wall bracket set 66 300308 TMS 55 PSU 140 347001 TEI 01 DC power inserter 197 140033 Wall bracket GF 85 wall bracket set 66 300310 TMS 55 PSU 140 590205 Triatan 18 05 cable assembly 212 128050 Wall Bracket Type J 96 300313 TM
200. S 55 Tap 137 153542 Triatan 18 10 cable assembly 212 128070 Wall Bracket Type S 96 300333 TMS 55 Tap 15dB 137 127100 Triax 2561 Stand 96 128080 Wall Bracket Type U 96 300343 TMS 55 Tap 20dB 137 111010 Triax DVB T 300i active indoor antenna 30 160922 Wall cabinet 11S 10 126 300353 TMS 55 Tap 24dB 137 300053 TRIAX Satselecet DISEqC motor 95 160622 Wall cabinet 11S 6 126 300363 TMS 55 Tap 6S 137 126382 Triax TDE 110 RAL 7016 77 160822 Wall cabinet 11S 8 126 153058 TMS 5 way bar 148 126380 Triax TDE 110 RAL 7035 T7 737030 Wheels 4 pcs with lock 123 300312 TMS 5x12 134 126381 Triax TDE 110 RAL 8012 T1 130009 Window bracket type MT 64 300322 TMS 5x12p 135 123792 Triax TDE 78 RAL 7016 T7 130016 Window bracket type MT short 64 300332 TMS 5x12p UK 135 123790 Triax TDE 78 RAL 7035 77 133025 Wirelock 3mm 69 300317 TMS 5x16 134 123791 Triax TDE 78 RAL 8012 DO 133021 Wirelock 5 mm 69 300327 TMS 5x16p 135 126387 Triax TDE 88 RAL 7016 77 XYZ 300337 TMS 5x16p UK 135 126385 Triax TDE 88 RAL 7035 77 107310 YAGI 10el ch 21 37 with F connector 18 300314 TMS 5x4 134 126386 Triax TDE 88 RAL 8012 TT 107317 YAGI 10el ch 21 69 with F connector 18 300324 TMS 5x4p 135 300349 Triax TMB 002 mono block LNB 90 107347 YAGI 15el ch 21 47 with F connector 18 300334 TMS 5x4p UK 135 300415 Triax TQD001 Universal quad LNB 91 107350 YAGI 15el ch 21 69 with F connector 18 300316 TMS 5x6 134 300436 Triax TQD002 Universal quad LNB 90 107348 YAGI 15el ch 2
201. S 88 Bulk w single Ral 7035 100 pcs pll 122868 TDS 88 Bulk w single Ral 7016 100 pcs pll TD bulk dishes 122869 TDS 88 Bulk w single Ral 8012 100 pes pll 122823 TDS 88 Bulk w single Ral 7030 100 pcs pll PartNo _ TDS steel dishes 122904 TDS 110 Bulk w single Ral 7035 50 pes pll 122525 TDS 54 Bulk Ral 7016 200 pes pll 122924 TDS 110 Bulk w single Ral 7030 50 pcs pll 122526 TDS 54 Bulk Ral 7035 200 pes pll 122926 TDS 110 Bulk w single Ral 7016 50 pcs pll 122547 TDS 54 Bulk Ral 8012 200 pes pll Part No TDA amnium EEEa 122617 TDS 64 Bulk Ral 7035 100 pcs pll 123666 TDA 64 Bulk w single Ral 7035 100 pcs pll 122624 TDS 64 Bulk Ral 7030 IU pes pll 123749 TDA 78 Bulk w single Ral 7035 100 pcs pll 122625 TDS 64 Bulk Ral 7016 IU pes pll 123754 TDA 78 Bulk w single Ral 7016 100 pcs pll 122647 TDS 64 Bulk Ral 8012 100 pes pll 123867 TDA 88 Bulk w single Ral 7035 100 pes pll 122717 TDS 78 Bulk Ral 7035 100 pes pll 123868 TDA 88 Bulk w single Ral 7016 100 pcs pll 122724 TDS 78 Bulk Ral 7030 100 pes pll 123869 TDA 88 Bulk w single Ral 8012 100 pes pll 122725 TDS 78 Bulk Ral 7016 IU pes pll 122824 TDS 88 Bulk Ral 7030 100 pcs pll 122825 TDS 88 Bulk Ral 7016 100 pcs pll 122826 TDS 88 Bulk Ral 7035 100 pcs pll 122847 TDS 88 Bulk Ral 8012 100 pcs pll Part No TDA aluminium dishes 123647 TDA 64 Bulk Ral 8012 100 pcs pll 123648 TDA 64 Bulk Ral 7035 100 pcs pll 123747 TDA 78 Bulk Ral 8012 100 pcs pll 123748 TDA 78 Bulk Ral 7035 10
202. Split Split Split beam beam beam beam BIII 10 elem Gain BIll 13 elem Gain 6 d 8 9 10 11 12 Ch 11 13 elem Ch 8 10 elem Ch 10 13 elem 15 Triax Digi band IV V aerial UHF TRIAX Digi aerials have been designed for UHF reception and are available in band IV ch 21 37 and band IV V ch 21 69 versions featuring high gain and channel selectivity With their excellent gain and excellent front to back ratios these aerials ensure superior TV reception The Digi 6 aerial is only available in channel 21 69 versions The aerials are made of an aluminium magnesium and manganese alloy which is extremely resistant to sea fog and acid rain Digi 6W Technical data DIO PM Digi 6W Digi 10A Digi 10W Digi 10W Digi 10W UHF UHF UHF UHF UHF UHF 108200 108800 108310 108311 108808 108319 Channel 21 69 21 69 21 69 21 37 21 69 21 69 21 69 Band BIV V BIV V BIV V BIV BIV V BIV V BIV V Elements pcs 6 6 6 10 10 10 10 Gain dBi 8 5 8 5 8 5 12 5 12 5 12 5 12 5 Front to back ratio dB 17 17 17 21 21 21 21 Beamwidth hor deg 25 25 25 23 23 23 23 Windload N 14 14 14 26 22 22 22 Weight kg 0 45 0 45 0 45 0 70 0 65 0 65 0 65 Material Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 718 718 718 1182 975 975 975 width mm 260 260 260 350 350 350 350 Connector SC type SC t
203. TA 102 80229 TLT 217 188 ao EO Gg bezo Sa Ge 590705 TDH Slave DVB S T Nicam 103 80230 TLT 220 188 bag Ge Gia Get B Za Ga 7 590745 TDH Slave DVB S T Nicam 103 80244 TLT 223 189 ee o 301791 TDH Stand alone unit 100 80245 TUT 226 189 Zka 364021 TDL 200Power wire 148 80246 TLT 226 189 123846 TDA 88 Bulk Ral 7016 100 pcs pll 82 364404 TDM 404 142 80247 TLT 232 189 123868 TDA 88 Bulk w single Ral 7016 100 pcs pll 82 364406 TDM 406 142 80248 TLT 235 189 123867 TDA 88 Bulk w single Ral 7035 100 pcs pll 82 364408 TDM 408 142 80249 TLT 408 190 123869 TDA 88 Bulk w single Ral 8012 100 pcs pll 82 364504 TDM 504 143 80231 TLT 411 190 123861 TDA 88 Single EUROLINE Ral 7016 81 364506 TDM 506 143 80235 TLT 414 190 123860 TDA 88 Single EUROLINE Ral 7035 81 364508 TDM 508 143 80232 TLT 417 190 123862 TDA 88 Single EUROLINE Ral 8012 81 r 346094 TDP 4 delivery point 186 80233 TLT 420 190 123812 TDA 88 Single packed Ral 7016 79 r r 346097 TDP 7 delivery point 186 80251 TLT 423 191 123818 TDA 88 Single packed Ral 7035 79 a cae be 364050 TDR 200 splitter 146 80252 TU 426 191 A packed hat 122926 TDS 110 Bulk w single Ral 7016 50 pes pll SO 80253 TLT 429 191 364200 TDC 200 Active DiSEqC switch 2 SAT TV 144 364250 TDC 250 Active DISEGC switch 2 SAT 4 t 145 122924 TDS 110 Bulk w single Ral 7030 50 pcs pll 82 80254 ITZ ISI Cie ORG SWIC dE 122904 TDS 110 Bulk w single Ral 7035 50 pcs pll SO 80255 TLT 435 191 364300 TDC 300
204. TMS 55 6S splitter 300363 TMS 510 splitter 300319 Number of inputs 4 SAT 4 SAT 4 SAT 4 SAT 4 SAT 4 SAT 1 TER 1 TER 1 TER 1 TER 1 TER 1 TER Number of outputs 4 SAT 4 SAT 4 SAT 4 SAT 8 SAT 8 SAT 1 TER 1 TER 1 TER 1 TER 2 TER 2 TER Number of taps 4 SAT 4 SAT 4 SAT 4 SAT 1 TER 1 TER 1 TER 1 TER Connectors F con female female female female female female Frequency range SAT MHz 950 2150 950 2150 950 2150 950 2150 950 2150 950 2150 Frequency range MHz 47 862 47 862 47 862 47 862 47 862 Through loss SAT dB 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 4 1 Through loss TER dB 2 0 41 5 2 0 1 5 2 0 1 5 2 0 1 5 6 1 Tap loss SAT dB 12 5 15 20 24 6 0 Tap loss TER dB 12 5 15 20 24 Isolation trunkline dB gt 30 gt 30 gt 30 gt 30 gt 30 gt 30 Isolation SAT TER dB Isolation TER SAT dB Power consumption VA Temperature range GE 0 55 0 55 0 55 0 55 0 55 0 55 Dimensions height mm 145 145 145 145 145 145 width mm 119 119 119 119 119 119 depth mm 42 42 42 42 42 42 137 Triax TMS 17 9 5 IF amplifiers oc BE EAM ES ED Ne EZ oi ed GZ ed ee THS PAME TE a e Boost your signal to get more mileage ee a Using a TMS line amplifier you can compensate for the cable loss in your ae 2 2 Slam Ft distribution system ETETE T BT EE
205. TOU Cover plate 2 hole Off White 80x80mm 232 140048 Wall bracket 2 3 legs 25 50 cm 64 303680 TOU Cover plate 2 hole White 80x80mm 232 140045 Wall bracket 3 legs 64 303690 TOU Cover plate 2 hole white 86x86 UK 232 140044 Wall bracket extra leg 64 257 General sales and delivery conditions 1 APPLICATION All sales of the seller s products are made according to the following conditions which have preference to any stipulations laid down in the buyer s order acceptance including buyer s general conditions unless otherwise stated in a written agreement and in that case with an exact indication of the points from which these sales and delivery conditions are deviating 2 QUOTATION AND ORDER CONFIRMATION Quotations made by the seller are open for 30 days from the date of the offer unless otherwise specified 3 PRODUCT INFORMATION Information and Technical data on seller s products stated in catalogues leaflets and other written material are only to be considered as approxIMDte and not binding on seller unless a written agreement explicitly states otherwise _ All drawings and technical specifications handed over to buyer prior to or after entering into an agreement remain seller s property No material must be used or copied by the buyer without the seller s written permission neither must it be reproduced handed over nor brought to the knowledge of a third party for another purpose than t
206. TV star or tree structure i J GE TV Radio Multimedia Sat Sat Network structures Floor star Star network Tree network Tree and star network 214 Triax outlets TOU series standard multimedia satellite TD series standard multimedia satellite special TD outlets OPUS series standard multimedia satellite Triax UK series Triax GAD series Triax GRID series Accessories TOU covers frames terminators TD covers frames terminators GAD covers frames terminators 216 220 221 224 225 226 221 228 229 230 231 232 233 234 Triax TOU tv radio outlets Triax TOU standard tv radio high quality outlets The Triax TOU series of outlets is made of diecast aluminium the coax IEC connectors fulfil the DIN 45325 and IEC 169 standards The outlets can be built into a 60 mm round wall box or surface mounted by means of a TOU frame Technical data 5 862 MHz standard outlets TOU tv radio outlet housing TYPE TOU 1DC TOU 1 TOU E TOU 1FB TOU 4 Part No incl cover and frame excl cover and frame 303620 303621 303619 303664 303624 Outputs TV Radio TV Radio TV Radio TV Radio TV Radio Frequency range TV MHz 5 74 120 862 5 74 120 862 5 74 120 2150 5 74 120 2150 5 74 120 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 87 5 10
207. Teardrop Door type Hinged Hinged Hinged Cable entries pcs 3 in bottom 3 in bottom 3 in bottom Packing Carton box Carton box Carton box Weight kg 14 4 14 4 14 4 Remarks EMKA lock EMKA lock EMKA lock included included included 11S 8 cabinet 126 Triax terrestrial sat amplifiers ACB series 128 ACB series 128 127 Triax Sat IF distribution amplifiers Reliable in house distribution amplifiers Combined RF and sat IF distribution amplifiers for small to medium sized buildings ACB 280 amplifier ATB 2150 amplifier Technical data on Sat IF distribution amplifiers TYPE ACB 280 ATB 2150 Part No 324280 300570 Forward path Frequency range Terrestrial MHz 10 862 86 862 Satellite MHz 950 2150 950 2150 Gain Terrestrial dB 2 0 20 28 Satellite dB 21 28 20 28 Noise figure Terrestrial dB lt 5 0 Satellite dB lt 8 0 lt 10 0 Linearity dB 1 0 1 0 Attenuation Terrestrial dB 0 12 Satellite dB 0 10 0 10 Equalizer Terrestrial dB 8 0 fixed Satellite dB 8 0 fixed Inputs outputs pcs 2 1 1 1 Output level 1 DIN EN 50083 Part 3 CTBA Terrestrisk EON 116 0 Composite triple beat ratio 60 dB IMR Sat IM3 35 dBuV 116 0 116 0 CENELEC raster 42 channels Isolation SAT TV dB TV SAT dB Return loss 1 5 dB octave dB gt 14 47 MHz gt 14 86 MHz Return path Frequency
208. Triax UNIX 100 band IV V aerial UHF TRIAX UNIX aerials have been designed for UHF reception and are available in 100 element version for channel groups as well as wideband With their excellent gain and excellent front to back ratios these aerials ensure superior TV reception The aerials have been designed to ensure optimum reception even under difficult conditions Easy and uncomplicated mounting is ensured by the snap lock dipole house made of UV resistant blue plastic The newly developed balun with capacitive signal transfer from the dipole ensures matching adjustment with lower insertion loss At the same time galvanic corrosion between the different materials in contact with each other is avoided The aerials are made of salt water resistant aluminium ensuring long service life UNIX 100 is provided with a support boom and all types are provided with elevation type mast brackets O EZS we UNIX 100 Technical data UNIX 100 UNIX 100 UNIX 100 UNIX 100 UNIX 100 UNIX 100 digital digital digital 108754 108755 108756 107768 107769 107756 Channel 21 40 21 50 21 69 21 50 21 69 21 69 Band Group Group BIV V Group Group BIV V Elements pcs 100 100 100 100 100 100 Gain dBi 17 0 17 0 17 0 17 0 17 0 17 0 Front to back ratio dB 27 27 27 27 27 27 Beamwidth hor deg 11 11 11 11 11 11 Windload N 176 152 152 176 152 152 Weight kg 3 19 2 50 2 46 2 50 2 46 2 46 Materia
209. Typ 20 min 25 Typ 20 min Power requirements DC current consumption typ mA 150 110 110 Operating voltage Vertical VDC 10 5 14 5 10 5 14 5 10 5 14 5 Horizontal VDC 15 5 21 15 5 21 15 5 21 Switching Low band Hz 0 0 D High band KHz 22 4 22 4 22 4 Operating temperature range C 40 60 40 60 40 60 Dimensions Diameter mm 40 40 40 Width x Heigth x Depth mm 599 x 59x 112 59x 59x 112 59x 59x 112 Max depth incl feedhorn mm 112 112 112 Weight kg 0 130 0 025 0 130 0 025 0 130 0 025 Packing size pcs 50 50 50 89 Triax LNB units the best choice Complete range of LNB units adopting the latest cutting edge RF technology Full KU band coverage for both analogue and digital reception Excellent noise figure and low phase noise High gain and excellent cross pole isolation High output and low power consumption Qualified for harsh environments Waterproof b Single packed in gift box b Po bp be bu Technical data TTW 002 TQD 002 TQT 002 TMB 002 Twin universal Quad universal Quattro universal Mono block 300435 300436 300438 300439 Colour light grey Ral 7035 Ral 7035 Ral 7035 Ral 7035 RF input Input frequency range Low band GHz 10 7 11 7 10 7 11 7 10 7 11 7 10 7 11 7 High band GHz 11 7 12 75 11 7 12 75 11 7 12 75 11 7 12 75 Feedhorn GHz F D 0 615 11 7 F D 0 615 11 7 F D 0 615 11 7 F D 0 615 11 7 IF output Output frequenc
210. VHF 8 9 Window and wall brackets 64 66 TDE series 77 BII DAB FM 10 11 Mounting pipes 67 TD series 78 82 BIII VHF 12 15 Brackets 68 Basic series 83 BIV V UHF 16 24 Wires and accessories 69 DAP series 84 Combi 25 26 Chimney brackets 70 Elliptical perforated 85 UFO 27 28 Roof covers 71 Unique 86 NMTand GSM 29 Cable guards and duct 72 LNB brackets and spare parts 87 88 Indoor 30 Screw bolts clips and strips 73 74 Universal LNB units Terrestrial electronics single twin quad quattro 89 92 mast amplifiers 32 48 DiSEqC switches 93 94 mast combiners 49 56 Polarmount and LNB covers 95 single channel filters 57 Mounting accessories 96 97 notch filters 58 stacking combiners 59 Headends Terrestrial SAT amplifiers TMS multiswitches TDH 700 headend 100 111 ACB series 128 TMS series TCH 600 headend 112 114 ATB series 128 17C and 17T series 130 131 TNH 600 single channel 115 9C and 9P series 132 133 TCM 08 modulator 116 5 and 5P series 134 135 CM 01 modulator 117 2C series 136 TMB programmable ampl 118 IF taps splitters 137 AS single channel amplifier 119 IF amplifiers 138 139 ARM multiband amplifier 120 IF power supplies 140 141 IFM_multiband amplifier 121 Districom 4000 142 147 SCT IF IF converter 122 Accessories 148 Headend mounting accessories TCC compact cabinet 123 TMF frame system 124 MDU 11S cabinets 125 126 EIA Tabl
211. VHF S channels Part No Type oN TDH channel f ilter Channel filter UHF channels Part No Type 301371 S 1 2 TDH channel filter 301372 S 2 3 TDH channel filter 301373 S 4 5 TDH channel filter 301374 S 6 7 TDH channel filter 301375 S 8 9 TDH channel filter 301376 S 10 Ch 5 TDH channel filter 301377 Ch 6 7 TDH channel filter 301378 Ch 8 9 TDH channel filter 301379 Ch 10 11 TDH channel filter 301380 Ch 12 S 11 TDH channel filter 301381 S 12 13 TDH channel filter 301382 S 14 15 TDH channel filter 301383 S 16 17 TDH channel filter 301384 S 18 19 TDH channel filter 301385 S 20 21 TDH channel filter 301386 S 22 23 TDH channel filter 301387 S 24 25 TDH channel filter 301388 S 26 27 TDH channel filter 301389 S 28 29 TDH channel filter 301390 S 30 31 TDH channel filter 301391 S 32 33 TDH channel filter 301392 S 34 35 TDH channel filter 301393 S 36 37 TDH channel filter 301394 S 38 39 TDH channel filter 301395 S 40 41 TDH channel filter 110 301321 Ch 21 22 TDH channel filter 301323 Ch 23 24 TDH channel filter 301325 Ch 25 26 TDH channel filter 301327 Ch 27 28 TDH channel filter 301329 Ch 29 30 TDH channel filter 301331 Ch 31 32 TDH channel filter 301333 Ch 33 34 TDH channel filter 301
212. YPE FILTER VERSION F334353 2360 A1 CH 33 43 50 CH 23 60 Rest UHF BI BII BI g Ta De d ie a a ETT BEE we po 60 Bre 19 STS G19 Gi 16 G16 Gio F 3153 00Ax multi channel combiner E OUT Technical data on multi channel mast combiners with saddle and clamp connectors F 3153 00 F 3153 00 F 334350 00 F 334350 00 F 334350 A2 A3 A2 A3 2360 A1 317229 317228 317236 317237 317233 Input 1 Band UHF UHF UHF UHF UHF Channel 31 53 31 53 33 43 50 33 43 50 31 53 Through loss dB 4 0 4 0 4 0 4 0 4 0 Input 2 Band rest UHF rest UHF rest UHF rest UHF UHF Channel 23 60 Through loss dB 1 0 1 0 1 0 1 0 1 5 Input 3 Band VHF VHF VHF VHF UHF Channel 2 12 2 12 2 12 2 12 33 43 50 Through loss dB 1 0 1 0 1 0 1 0 3 0 1 5 Input 4 Band Bill Channel 5 12 Through loss dB 1 0 Input 5 Band BI FM Channel Through loss dB 1 0 Stop band attenuation VHF BI dB gt 20 gt 20 gt 20 gt 20 gt 20 FM dB gt 20 gt 20 gt 20 gt 20 gt 20 Bill dB gt 20 gt 20 gt 20 gt 20 gt 20 UHF dB gt 20 gt 20 gt 20 gt 20 gt 20 SAT dB Numbers of in output 3 1 3 1 3 1 3 1 5 1 DC throughpower Ch 31453 rest UHF Ch 33 43 50 rest UHF Switchable input input all inputs Connector S amp C S amp C S amp C S amp C S amp C Weight kg 0 5 0 5 0 5 0 5 0 5 Dimensions Height mm 122 122 122 122 122 Depth mm 55 55 55 55 55 Width mm 168 168 168 168 168 Remarks
213. able EU directives currently EMC and low voltage directives as well as with the standards EN 50083 1 EN 50083 2 and EN 60065 For receivers the standards EN 55013 EN 55020 and EN 61000 are applied The CE marking is placed on the product on the packaging and or included in the operating instructions To prevent interference between TV cable networks and radio services it is necessary to use components with sufficient shielding Due to the varying conditions in the European countries the shielding rate was defined in the European standard EN 50083 2 in two stages the high quality class A and class B with reduced shielding rate values For example the high radio density present in many parts of the world makes the usage of class A equipment necessary to prevent interactions particularly with safety relevant radio services such as air traffic control As a differentiation in the appearance of the equipment for trade and installers is not possible Triax and the other H companies in the Fachverband Empfangsantennen und Breitbandverteiltechnik A im Zentralverband Elektrotechnik und BCLASS Elektroindustrie ZVEl e V mark the products with the protected trademark symbol shown In this way the higher quality of the equipment is made clear See 3 3 Shielding rate For compliance with the legal EMC requirements for TV cable networks we expressly recommend the usage of class A components including connecting cables so marked
214. ables offering high stability in many years to come With meter marking and physical foam dielectric All cables meet European standard EN 500117 Outdoor cables must be unbroken and cables under ground must be a least 45 cm below the surface RG 11 Bedea 110 KU 1 1 7 3 Double shielded Double shielded Black White Black White PE LZW RE LZW Part No Cardboard roll 100 m Cardboard roll 200 m Plastic reel 100 m Wood 150030 Plastic reel 250 m drum 150098 Plastic reel 500 m 150062 150099 150031 Center conductor mm 1 7 1 1 Center conductor material Cu blank Cu blank Isolation mm 7 2 4 9 Dielectric PEE foamed PE foamed Screen Al PET AI Cu foil um Braid e material CuSn Cu construction mm coverage 56 0 Screening attenuation dB Anti migration foil um Outer sheath PE PE Minimum bending radius mm 100 120 70 Diameter mm 10 25 7 3 Application Outdoor Outdoor ELECTRICAL DATA Impedance Ohm 75 75 Capacitance pF m 53 55 Velocity ratio 84 81 Center conductor dc resistance Ohm km 7 8 18 Outer conductor dc resistance Ohm km 9 7 11 Attenuation at 20 C 5 MHz dB 100m 0 8 1 3 50 MHz dB 100m 2 6 4 1 200 MHz dB 100m 5 5 8 2 470 MHz dB 100m 8 9 13 9 600 MHz dB 100m 10 0 15 7 800 MHz dB 100m 11 4 18 1 1000 MHz dB 100m 13 5 20 2 1350 MHz dB 100m 15 6 24 9 1750 MHz dB 10
215. action last if signals deteriorate due to corrosion of the reflector or if the dish is damaged by a storm TD dishes minimize problems of any kind Long term corrosion is prevented by an extremely thorough anti corrosive process and polyester coating A solid construction of all parts including the non slip mast brackets ensures that the dish remains in its correct position when other dishes are torn down or twisted by a heavy storm Mounted and adjusted in two minutes Saving trouble and money is not only a long term consumer benefit TD dishes allow a substantial reduction in time used for mounting and adjusting 1 The elevation bracket is pre mounted and is easily fixed to the mast with non slip mast brackets 2 A setting scale on the elevation brackets facilitates precise adjustment to the required satellite 3 The pre mounted feedarm just needs unfolding and the LNB holder with the LNB is simply clicked on Technical data on TDS steel dishes Ral 7035 Ral 7030 TDS 54 TDS 64 TDS 78 TDS 88 TDS 110 50 x 56 cm 60 x 65 cm 70 x 78 cm 85 x 95 cm 100 x 105 cm Part No Light grey Ral 7035 122518 122618 123718 122818 122908 Grey Ral 7030 122510 122610 122710 122810 Anthracite Ral 7016 122512 122612 123712 122812 122912 Red Ral 8012 122910 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 34 2 35 8 37 1 38 8 40 2 G T
216. aerial DVB T 300i 88 108 MHz Ch 2 69 active aerial 108951 111000 111010 Channel Ch BII 2 12 5 12 Ch 21 69 21 69 Frequency range MHz 88 108 47 862 174 230 MHz 470 862 Elements Pcs 1 1 1 Gain dB 15 0 Noise figure VHF UHF dB 3 4 3 5 Max output voltage IMA3 ZEON 93 0 Front to back ratio dB gt 25 0 Beamwidth hor de 90 180 180 Windload N Weight kg 0 300 0 120 Material Aluminium Aluminium Aluminium Colour Matte black Dimensions length mm 1500 1439 145 width mm 10 420 60 depth mm 10 7 9 Connector IEC type IEC type IEC type Voltage V DC 4 5 via coax cable Remarks Also suitable Suitable for DVB T for DVB T deliveres in a 1 pcs blister pack 30 Terrestrial electronics mast amplifiers combiners single channel filters notch filters stacking combiners 32 48 49 56 57 58 59 Triax pre amplifiers series 8000 80000 TRIAX s range of series 8000 HF tight amplifiers in metal housings includes channel amplifiers for BIIl and UHF as well as band amplifiers for FM BIIl and broadband amplifiers for UHF Besides the 8003K 81065 and 81065K types are available with built in overload protection Technical data on series 8000 low noise pre amplifiers with PG11 connectors 8000 1 8000 1K 8000 2A 8000 3 8000 3K 8000 3 Band I Band Band Il Band III Band Ill Band Ill 325830 325857 325835 325838 325856 325808 Input frequency ran
217. ag Cable stand Part No 150110 207 Matching connectors for your RF cable Choosing the right connector for your cable is very important Suitable connector Type of cable KOKA QX 5 Mini RG11 Bedea 100 110 Connector part no Crimp connector 100 pcs box ex logo 153200 153200 100 pcs box 153203 153201 153203 153201 153204 153240 153211 153203 100 pcs box EPA 153202 153202 25 pcs box EPA 153230 50 pcs box 153231 Compression connector 100 pcs box 153221 153220 153221 153220 153221 153221 50 pcs box 153222 5 pcs box 1 pos Twist on connector 100 pcs box 153073 153073 153072 153073 153074 153073 5 pes box 153063 153053 153048 153053 153049 153053 153053 1 pos Suitable tooling Type of cable KOKA KOKA KOKA KOKA QX4 QX 5 Mini RG11 Bedea Multi 100 80 6 6 CCS 110 4 5 9 Tooling type Stripping tool Type K 153602 X X X X X X X Type L 153602 X Crimp tool Crimp connector A A A A A A B A A Compression connector E E E E E E E Twist on connectors 208 Part No 153607 CRP 106H crimp tool is for 324 8 2 mm and 360 9 2 mm one piece F connectors and EPA typically used with RG 6 and QX 5 cables Part No 1538603 Compression tool universal RG 6 RG 11 is used for compression type F connectors for outdoor use and ensures waterresistant connections Part No 153633 Mountin
218. ain dB 12 22 12 22 15 25 Input 3 Band BI FM BI FM Channel Gain dB 2 12 15 25 Noise figure UHF dB 5 0 4 0 4 5 VHF dB 3 0 4 0 4 0 Max output voltage 60 dB IMA dBuvV 103 105 103 Numbers of in output 2 1 3 1 3 1 Voltage V AC 230 230 230 Power consumption W 2 3 3 Connector type F F F Impedance Ohm 75 75 75 Operation temperature range C 0 50 0 50 0 50 Weight kg 0 400 0 400 0 400 Dimensions h x d x w mm 61x44x118 61x 44x 118 65 x 50x 173 Remarks Automatic DC pass to UHF input 121 Triax SCT 100 IF IF converter SCT 100 is a compact SAT IF channel converter for 10 channels which makes it practicable to convert analogue and digital channels from different satellites SCT 100 converts any required SAT IF channel from its origin position into a free choice able frequency back again in the SAT IF The SCT 10 SAT IF unit can be inserted into existing tree distribution networks if the existing cable is suitable for up to 2150 MHz Not applicable for building a new cable system Only the splitters taps and outlet of the distribution system must be changed to the SAT IF range e Programmable SAT IF channel processing system for 10 digital and analogue channels SCT 100 IF IF converter e AGC operation e LNB remote feed voltage on each input e Integrated power supply and programming unit e Output level separately adjustable for each channel SE Technical data SCT 100 IF IF converter
219. alue in the catalogue has to be multiplied by 1 37 2 5 Permissible output level for active elec tronic equipment Specification of the permissible output level is made according to EN 50083 3 Active broadband equipment for coaxial cable networks for a signal to noise ratio of e IMA 60 GB for amplifiers for AM QAM and FM signals in SMATV MATV broadband cable CATV installations e IMA 35 dB for amplifiers for FM signals only satellite IF transmission 244 Now that this measurement method is standard throughout Europe this important parameter has become transparent and comparable With the aid of this information the network planner and installer are able to determine the optimum amplifier gain refer also to the planning instructions to maintain the required minimum signal to noise ratios for a given number of channels This procedure provides considerable advantages wherever new networks with a minimum number of amplifiers cost ad vantage are planned or where overriding regulations apply for certain parts of the network For example the permissible output level for a house connection amplifier to a house connection point is explicitly specified at CTB CSO 66 dB This means that the required signal quality CTB CSO 57 dB according to EN 50083 7 can be maintained up to the sub scriber s connection Other permissible output levels are also given on the one hand for the CENELEC spacing EN 50083
220. and easy programming KE e Analogue satellite modules available in DSB Ee j e Modulator modules available in DSB and VSB we Wes E e Individual adjustment of output levels i MM ae b TS TCH 600 Technical data TCH 600 basic unit TCH 600 basic unit 490600 Number of inputs 1 Number of combined outputs 1 Number of module space 8 analogue Frequency range TV in TV out module RF in MHz 47 862 Output level 8 combined channels max 54 dB IMD EON 100 max 60 dB IMD dBuV 90 Return loss TV in TV out module RF in dB gt 10 Through loss TV in IN out dB 4 Impedance Ohm 75 Operation voltage V AC 190 260 Power consumption W 65 max TV converter Connector in out F female Operation temperature range oC 0 50 Weight kg 4 1 Dimensions H x D x W mm 200 x 130 x 440 FM converter Technical data TCCC and TCFC converters TCCC 677 TV converter TCCC 678 TV converter TCFC 679 FM converter 490677 490678 490679 TV standard system L D K B G Input frequency range MHz 47 862 47 862 87 5 108 Input level dBuvV 65 90 65 90 60 90 Output frequency range MHz 47 862 47 862 87 5 108 Output channel bandwidth MHz 8 7 Output level dBuvV 90 100 90 100 82 92 Output level attenuator dB 0 10 0 10 0 10 Impedance Ohm 75 75 75 Temperature range oC 0 50 0 50 0 50 Weight kg
221. ast filter ch 51 58 333582 TC 1221 55 333258 SCA 2058 amp ch 58 47 314052 SCS F7000 52 mast filter ch 52 58 331381 TC 335 56 333259 SCA 2059 amp ch 59 47 314053 SCS F7000 53 mast filter ch 53 58 331382 TC 335DC 56 333260 SCA 2060 amp ch 60 47 314054 SCS F7000 54 mast filter ch 54 58 331383 TC 356 56 333263 SCA 2063 amp ch 63 47 314055 SCS F7000 55 mast filter ch 55 58 364003 TCB 003 Camera BW 236 333264 SCA 2064 amp ch 64 47 314056 SCS F7000 56 mast filter ch 56 58 364007 TCB 007 Camera colour 237 333265 SCA 2065 amp ch 65 47 314057 SCS F7000 57 mast filter ch 57 58 364008 TCB 008 Camera colour 237 333266 SCA 2066 amp ch 66 47 314058 SCS F7000 58 mast filter ch 58 58 364011 TCB 011 Camera colour 237 333267 SCA 2067 amp ch 67 47 314059 SCS F7000 59 mast filter ch 59 58 364015 TCB 015 Camera BW 236 333268 SCA 2068 amp ch 68 47 314060 SCS F7000 60 mast filter ch 60 58 364017 TCB 017 Camera colour 237 333269 SCA 2069 amp ch 69 47 314061 SCS F7000 61 mast filter ch 61 58 490600 TCH 600 BASIC UNIT 112 333220 SCA 439 443 MHz amp 47 314062 SCS F7000 62 mast filter ch 62 58 490679 TCH FM converter 112 331421 SCF 21 15A3 comb K21 57 314063 SCS F7000 63 mast filter ch 63 58 490678 TCH TV channel converter 7 MHz 112 331422 SCF 22 15A3 comb K22 57 314064 SCS F7000 64 mast filter ch 64 58 490677 TCH TV Channel converter 8 MHz 112 331423 SCF 23 15A3 comb K23 57 314065 SCS F7000 65 mast filter ch 65 58 300110 TCM 08 Basic Unit
222. ation SAT dB 0 to 10 0 to 10 D to 10 Isolation dB gt 30 dB typ gt 30 dB typ gt 30 dB typ 25 dB min 25 dB min 25 dB min Isolation SAT TER dB gt 30 dB typ gt 30 dB typ gt 30 dB typ 20 dB min 20 dB min 20 dB min Impedance Ohm 75 75 75 Return loss SAT TER dB gt 10 0 gt 12 0 gt 10 0 gt 12 0 gt 10 0 gt 12 0 Output level dBuV 105 105 105 Noise figure dB lt 7 lt 7 lt 7 DiSEqC control DiSEqC DiSEqC 1 0 DiSEqC 1 0 DiSEqC 1 0 Tone frequency kHz 22 4 22 4 22 4 Tone burst option A or B Selectable via switch Selectable via switch Selectable via switch Power supply voltage VDC 11 5 19 11 5 19 11 5 19 Power supply current mA lt 65 mA lt 65 mA lt 65 mA Max current pass mA 300 300 300 Temperature range GE 0 50 0 50 0 50 Dimensions H x D x W mm 113 x 66 x 22 mm 113 x 66 x 22 mm 149 x 66 x 22 mm 144 Triax Districom 4000 multiswitches TDC DiSEqC switches The TDC 250 350 and 450 series is for extension of existing systems enabling you to reuse the existing antenna cable by looping in the new satellite signals so there is no need to pull new cables into the subscriber s flat TDC 250 TDC 350 TDC 450 Technical data TDC Sat Ter DiSEqC switches TDC 250 364250 TDC 350 364350 TDC 450 364450 Satellite inputs via TDM module 2 3 4 Terrestrial inputs via TDM module 0 0 0 Inp
223. ave mod TDH 737 FM TDH 738 FM TDH 736 TDH 739 FM Free to air with CI Part No 490737 490738 490736 490739 Modulator type QPSK FM stereo QPSK FM stereo FM stereo FM stereo Band FM FM FM FM Input frequency range kHz 20 20 000 MHz 920 2150 920 2150 Input level dBuV 45 84 45 84 Modulation FM FM FM Output level max dBuV 92 92 92 92 Output level attennuator dB 10 Input Sat F female F female Loopthrough Sat Yes F female Yes F female Output frequency range MHz 87 5 108 0 87 5 108 0 87 5 108 0 87 5 108 0 Spurious signals ref pict carrier C N dB gt 60 gt 60 gt 60 Audio S N ratio dB 60 60 60 Audio distortion 1 kHz lt 1 lt 1 lt 1 Audio input level V RMS 0 5 V RMS Audio input output 15 pol SUB D Return loss MOD OUT dB gt 10 gt 10 gt 10 Output impedance Ohm 75 75 75 Temperature operation C 10 50 10 50 10 50 10 50 Weight standard module kg 0 45 0 45 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 Remarks Video audio cable 15 cm Part No 300748 Part No 300748 Phone Sub D 150 cm Part No 300745 Part No 300745 105 TDH digital analogue TV converters TV channel converter modules in the TDH range is converting any TV channel in the VHF and UHF band to another frequency For optimized function and performance in handling analogue or digital signals two di
224. ay bar 12 way bar 16 way bar Part No 370002 370003 370004 370005 Number of connectors 6 8 12 16 Connectors F con female to female female to female female to female female to female Remarks Push on type Push on type Push on type Push on type Technical data mounting plate for Districom TYPE TDF511 TDF512 Part No 364511 364512 Number of modules 5 5 Dimensions H x D x W mm 145 x 200 x 2 231 x 200 x 2 Remarks Small mounting plate Large mounting plate for easy fixing of modules for easy fixing of modules Technical data Connection cables for multi switches TDL 200 RMF high power cable grade cable 364021 364026 Dimension H x W x D mm T Bag with pcs 2 5 Remarks Power cable with With F quick connectors connectors Qs 148 Triax Distribution amplifiers Outdoor Indoor HNA series 150 HTA series 151 HDA series 152 HEA series 153 accessories 154 156 HFA series 157 accessories 158 HEF series 159 Indoor IFE series 160 161 IFA series 162 163 IEE series 164 IIB series 165 TA Type 02 ZIN 2TV series 166 a Ma PK E aL bad AZE Triax optical fiber node amplifiers HNA D and HNA E series of optical fiber node amplifiers Compact yet highly versatile the platform covers all needs for two way transmission in hybrid fibre coax HFC networks All amplifiers are suitable for establishi
225. ber rRiax CH xx AMPLIFIER Axx A1 EIS 9S G9 Ant VHF CH t 4 Ant TO VHF Power Supply OBRAK AMPLIFIER A88108A1 M VHF OUT 24V BI ELE E TS ES A88108 A1 FM amplifier A05 A1 1 channel amplifier Technical data on Axx single channel amplifiers with saddle and clamp connectors Type A88108 A1 AXX A1 AXX A1 AXX A1 AXX A1 AXXYY A2 Ch 5 6 Ch 7 8 Ch 9 11 Ch 12 multichannel Part No 326976 326905 326907 326909 326911 326980 Input 1 Channel FM 5 or 6 OE 9 or 11 12 XXYY Frequency MHz 88 108 BIII BIII BIII BIII Gain dB 15 25 25 25 25 25 Noise figure dB lt 3 0 lt 4 5 lt 45 lt 4 5 lt 4 5 lt 4 5 Input 1 Channel Bl Rest Rest Rest Rest Rest Frequency MHz VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Gain dB SO 1 1 1 1 1 Noise figure dB Max output voltage 60 dB IMA dBuV 112 116 116 116 116 116 Numbers of in output 2 1 2 1 2 1 2 1 2 1 2 1 Voltage VDC 24 24 24 24 24 24 Power mA 35 35 35 35 35 35 DC throughpower BI Switchable Switchable Switchable Switchable Switchable VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 250 0 250 0 250 0 250 0 250 0 250 Dimensions Height mm 90 90 90 90 90 90 Depth mm 48 48
226. by the proper party to continued use or he changes or replaces the product so that it no longer gives rise to an infringement If none of these alternatives can be achieved on terms that the seller finds reasonable he can claim that the buyer refrains from using the product against an allowance from the seller corresponding to the value of the product after depreciation with equal amounts every year compared to the technical and economical life of the product The size of such an allowance is not dependent on the question whether the product is integrated into another product or a building etc and it is not influenced by the loss which it and or discontinuance of use might cause the buyer In case of resale of the product the buyer is liable to include an identical stipulation in the agreement between buyer and buyer s customer including instruct the customer to include an identical stipulation for the customer s possible resale The seller s maximum responsibilities as to any potential infringement of the patent or another incorporeal right are defined above 12 COMPLAINTS Immediately on receipt and prior to taking the products into use the buyer should inspect the goods supplied to ensure that there are no shortcomings and that the correct quantity has been supplied Complaints of defects which have been found or should have been found at a general inspection must be made at once and not later than 8 days a
227. cal requirements All equipment and components in this catalogue meet unless otherwise stated the European standards for Cable networks for television signals sound signals and interactive services from the standardization organization CENELEC which have been adopted in national versions EN 50083 1 EN 50083 1 A1 EN 50083 1 A2 EN 50083 2 Safety requirements Electromagnetic compatibility EMC of equipment The equipment conforms to the uniform European EMC directive in accordance with legal requirements For the ma jority of the product groups in this catalogue EN 50083 2 is relevant In relation to the Low voltage directive EN 60065 is the basis to which reference is made in EN 50083 1 Safety requirements The CE marking for products in relation to EMC and the low voltage directive is based on these standards In addition CENELEC committee TC 209 has ratified European standards for equipment and system requirements for Cable networks for television signals sound signals and interactive services EN 50083 3 Active broadband equipment for coaxial cable networks EN 50083 4 Passive broadband equipment for coaxial cable networks EN 50083 5 Headend equipment EN 50083 6 Optical equipment EN 50083 7 System requirements EN 50083 8 Electromagnetic compatibility of cable networks EN 50083 9 Interfaces for CATV SMATV headends and similar professional equipment for DVB MPEG 2 transport streams
228. ce Ohm 75 75 75 75 75 Weight kg 0 092 0 092 0 092 0 092 0 092 Dimensions h x d x w mm 60x16x70 60x16x70 60x16x70 60x16x70 60x16x70 184 STT 6 16 348616 STT 6 20 348620 STT 6 24 348624 STT 6 30 348630 STT 8 16 348816 Triax taps STT series 5 2400 MHz STT 8 20 348820 Frequency range MHz 5 2400 5 2400 5 2400 5 2400 5 2400 5 2400 Outputs pcs 6 6 6 6 8 8 Insertion loss in out 5 40 MHz dB lt 4 5 lt 2 5 lt 2 0 lt 2 0 lt 4 5 lt 2 5 40 1000 MHz dB lt 5 0 lt 3 0 lt 3 0 lt 3 0 lt 5 0 lt 3 0 1000 1750 MHz dB lt 6 0 lt 4 0 lt 4 0 lt 4 0 lt 6 0 lt 4 0 1750 2150 MHz dB lt 7 0 lt 5 0 lt 5 0 lt 5 0 lt 7 0 lt 5 0 2150 2400 MHz dB lt 8 0 lt 6 0 lt 6 0 lt 6 0 lt 8 0 lt 6 0 Tap loss 5 40 MHz dB 16 0 2 0 20 0 2 0 25 0 2 0 30 0 2 0 16 0 42 0 20 0 2 0 40 1000 MHz dB 16 0 2 0 20 5 2 0 25 0 2 0 30 0 2 0 16 0 42 0 20 5 2 0 1000 1750 MHz dB 18 0 2 0 21 0 3 0 25 0 3 0 30 0 3 0 18 0 2 0 21 0 3 0 1750 2150 MHz dB 19 0 3 0 21 5 4 0 25 0 4 0 30 0 4 0 19 0 3 0 21 5 4 0 2150 2400 MHz dB 19 0 3 0 21 5 4 0 25 0 4 0 30 0 4 0 19 0 3 0 21 5 4 0 Isolation 5 40 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 12 0 gt 12 0 40 1000 MHz dB gt 16 0 gt 16 0 gt 16 0 gt 16 0 gt 12 0 gt 12 0 100
229. cl 2 plastic Incl 2 plastic For mounting dish on earth plugs plugs dish on roof wall Mounting accessories for dishes Bracket for Bracket for Tube Unique TD 110 5 x 95 cm 140050 140051 140007 Material Galv steel Galv steel Galv steel Tube dimension mm 60 60 50 x 950 Weight kg Packing type Single pcs Single pcs Single pcs Remarks For mounting For mounting For mounting Unique on mast Unique on mast in wall brackets 96 Wall mounts for dishes EXA 194 wall mount EXA 192 wall mount Technical data on EXA wall mount EXA 192 EXA 194 Alu Alu 131092 131094 Diameter mm 48 48 Clearance from wall mm 250 450 Plate dimension mm 155 x 155x3 155x 155x3 Material Aluminium Aluminium Weight kg Packing QTY pcs 10 10 97 98 Headends TDH 700 100 111 TCH 600 112 114 TNH 600 115 TCM 08 modulator headend 116 CM 01 single modulator 117 TMB programmable amplifier 118 AS single channel amplifiers 119 ARM multiband amplifier 120 IFM multiband amplifier 121 SCT IF IF converter 122 Headend mounting accessories TCC compact cabinets 123 TMF frame system 124 MDU lock box 11 S cabinets 125 126 TDH 700 main and sub unit digital Triax digital headend TDH 700 TDH 700 is a modern digital compact headend Each basic unit holds up to six Ak modules each carryin
230. d amplifier has all the features needed for amplifying and distributing a high number of signals into a network High flexibility 10 highly selective and adjustable filters in the UHF frequency range secure high flexibility Each of these clusters can have 1 6 channels 48 MHz bandwidth 6 inputs FM DAB VHF UHF and 3 UHF inputs split over 10 UHF programmable clusters Automatic or manual levelling of the signal Easy programming Designed for both digital and analogue operation TMB 6 324571 TMB 10A 324575 TMB 10B 324576 TMB 10S 324577 Numbers of inputs pcs 5 5 6 8 Numbers of outputs pcs 1 1 1 2 Numbers of filters 6 6 10 10 Test point pcs Yes 30 dB Yes 30 dB Yes 30 dB Gain Input BI FM dB 24 30 30 Input BIII DAB dB 35 40 40 45 Inout VHF and UHF aux dB 30 35 35 Input UHF 1 dB 48 60 60 55 Input UHF 2 dB 42 60 60 55 Input UHF 3 dB 30 60 60 55 Input satellite 1 dB 34 40 sloped Input satellite 2 dB 34 40 sloped Attenuation dB 0 20 0 20 0 20 0 20 Selectivity dB MHz 20 10 20 10 20 10 Noise figure VHF dB 9 0 3 0 8 0 8 0 8 0 DVB T UHF dB 6 0 6 0 6 0 VHF and UHF aux dB 6 0 6 0 6 0 UHF dB 3 0 5 0 5 0 6 0 6 0 6 0 Satellite dB 9 0 Output level IMD3 60 dB 3rd order Bl dBuvV 103 120 120 116 Bill dBuvV 108 120 120 118 VHF UHF aux GEUN 120 120 UHF dBuvV 112 115 112 124 124 120 SAT
231. d to times 3 15 70 112 101 Signal level is often stated in GEUN which is to be understood as the number of dB the signal exceeds IUN 9 Frequencies for radio and TV channels Frequencies of a TV signal Norm B G Pal 8 MHz channel raster 7 MHz channel raster 7 MHz raster Fl USB F Ill OSB 8 MHz raster ESB F IV F V 6 992 6 75 5 68 1 25 MHz Picture Color 2 Sound 1 Sound 251 Contents from A to Z 00 103862 Aerial 6el ch 5 12 with F connector 12 108011 BB grid ch 21 69 23 P 7 i 5 5 i ES 5 150030 1 1 7 3 Black Double shielded 100 m Plastic roll 205 0022 Aerial E Ed _1080113_B grid ch 21 68 2 pes perpack ___ 23 100329 Aerial 10el ch 7
232. d will not be refunded in case of a possible returning Multi way packing will be charged and credited to the customer in case of prompt and safe return Carriage paid The buyer shall reimburse the seller for any costs or charges for which the seller becomes legally liable in respect of the removal and disposal of packaging materials 9 TOOLS Applied tools which have been debited to the buyer wholly or in part according to agreement remain in the seller s warehouse but are not delivered The seller takes care of the proper maintenance of these tools If such tools are not used for 3 years the seller is no longer bound to keep and maintain them No liability rests with the seller for tools lent by the buyer if they have not been used for 2 years and not been demanded by then 10 PROPERTY INCORPOREAL RIGHTS The buyer does not acquire property and or inventor s rights other incorporeal rights to any computer programmes used for the product nor any drawings design technical solutions etc whether individually made for the buyer on his account or not since the buyer is only entitled to use such material in relation to the agreed application of the product 11 RESPONSIBILITY FOR VIOLATION OF PATENT AND OTHER INCORPOREAL RIGHTS If there should be a risk or if it is asserted that the product infringes a patent or another incorporeal right the buyer accepts that at his own option the seller is either allowed
233. demand at any time and the buyer is liable to give a banker s guarantee payable on demand in an acknowledged bank for the agreed payment or partial payment including costs and outlays if any For delivery of products that should form part of another product the seller is entitled to demand at any time and the buyer is liable to give a banker s guarantee payable on demand in an acknowledged bank for an amount corresponding to the purchase sum for the parts entered at the time in question but not yet paid If the buyer does not give such a banker s guarantee on request the seller is entitled to consider the agreement s non fulfilled wholly or partly and the seller is entitled to claim delivery of products that have not been used and not paid The buyer is thus unable to work with or otherwise use such products Payment has to be made at the time stated in the quotation or the order confirmation If the buyer does not pay in due time the seller reserves for himself the right to charge 2 interest on late payments for each new month The same interest is charged if a respite has been granted The buyer is not entitled to keep back payments or to set off against asserted claims that have not been accepted by the seller If the buyer does not want to receive the lot at the time agreed he is obliged to pay as if delivery had been made according to the agreement 8 PACKING Disposable packing has been included in the price an
234. dio 5 65 65 862 dB SAT TV 5 65 65 862 dB gt 12 gt 12 SAT out dB Radio TV dB gt 12 TV out dB Radio out dB Return loss TV EN 50083 4 dB Radio EN 50083 4 dB SAT EN 50083 4 dB Shielding factor VHF UHF dB SAT dB Connectors E lIEC male IEC male Radio lIEC female IEC female SAT F female F female DC through mA Max 250 Max 250 Standards CE Impedance Ohm 75 75 Weight kg 0 165 0 165 Dimensions w x h x d mm 50x77x26 50x77x26 Remarks Please refer to page 233 for cover frame and terminators 222 Triax TD multimedia tv amp radio outlets Triax s FUGA multimedia TV radio outlets have improved shielding factor and are much faster to mount The newly developed design where backplate and terminals are die cast in one piece sets new standards to shielding and mechanical stability e High HF tightness e Simple and quick mounting e Solid mechanical quality e Fulfil modern day s technical multimedia requirements TD multimedia outlet housing Technical data on multimedia outlets Data 5 65 or 5 42 MHz TYPE TD 272D TD 278 Terminated Loop through Part No white in bag 302422 302428 Part No grey in bag 303422 303428 Part No white in box Part No grey in box Outputs TV Radio TV Radio Data Data Frequency range TV MHz 139 862 47 862 Radio FM MHz 87 5 108 87 5 108 Data MHz 5 862 132 862 Returnpath MHz 5 65 5 65 Through loss 4 0 TV dB 4 0 Radi
235. dio outlets have improved shielding factor and are much faster to mount The newly developed design where backplate and terminals are die cast in one piece sets new standards to shielding and mechanical stability e High HF tightness e Simple and quick mounting e Solid mechanical quality e Fulfil modern day s technical multimedia requirements TD outlet housing Technical data on TD outlets 5 862 MHz TYPE TD 260D TD 263D TD 212B TD 280 Terminated Loop through Loop through DAB Part No White in bag 302510 302511 302412 10 2510 Part No Grey in bag 303510 303511 303412 303430 Part No White in box 302460 302461 Part No Grey in box 303460 303461 Outputs TV Radio TV Radio TV Radio TV Radio DAB Frequency range TV MHz 5 68 139 862 47 68 139 862 47 68 132 862 47 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 DAB MHz 175 862 Through loss TV dB 4 5 0 8 Radio dB 4 5 1 0 DAB dB Tap loss TV dB 1 0 4 5 13 0 4 5 Radio dB 1 5 4 5 13 0 5 0 DAB dB 4 5 Linearity TV radio dB 1 1 1 1 Isolation TV radio dB gt 12 gt 12 gt 18 gt 10 TV out dB gt 20 db 40 Mhz Radio out dB 1 5dB octave TV DAB DAB radio dB gt 20 Return loss TV EN 50083 4 dB gt 18 40 MHz Radio EN 50083 4 dB gt 18 40 MHz Shielding factor VHF 5 300 300 470 dB gt 85 gt 80 gt 85 gt 80 gt 75 UHF 470 862 dB gt 75 gt 75 gt 65 Connectors TV IEC male lIEC male I
236. ds LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 Linearity dB di 3rd order DIN 45004B dBuV 118 118 2nd order DIN 45004A1 dBuV 104 104 Noise Figure dB 6 6 General Line power voltage VAC 24 65 24 65 Line power current mA 750 330 870 380 Mains power voltage VAC 175 260 175 260 Power consumption incl return path W 13 5 16 0 Dimensions WxHxD mm 200 x 180 x 82 200 x 180 x 82 Weight kg 2 2 153 Triax Accessories for amplifiers MRT e optical return path transmitter modules features test point pilot tone option AO 801V1 only SC APC or E2000 optical connectors MCA 100 e automatic gain control features requires only one pilot frequency any tone or signal can be used as pilot very easy alignment procedure allows for compensation for seasonal temperatures prior to adjustment Automatic shift to manual function Technical data on MRT optical return path transmitter modules TYPE MRT 300L MRT 300 MRT 400 MRT 50X Type Part No MRT X00 SC APC 322290 322292 322294 322296 MRT X00 E2000 Return path 322291 322293 322295 322297 Type of laser Fabry Perot Fabry Perot DFB uncooled DFB uncooled CWDM Bandwidth MHz 5 65 5 65 5 65 5 65 Wavelength nm 1310 1310 131
237. e Hz 50 60 50 60 50 60 Max current A 1x 1 25 1x 1 25 1x 3 0 Output voltage VDC 15 0 5 15 0 5 15 0 5 Power VA lt 65 lt 65 lt 65 Cable length from supply mm 300 250 250 Colourcoding of IF and TER inputs Temperature range C 0 50 0 50 0 50 Dimensions H x D x W mm 145 x 138 x 36 95 x 60 x 20 95 x 60 x 20 Remarks Power adaptor unit Power adaptor unit Power adaptor unit 141 Triax Districom 4000 multiswitches Districom multiswitches are the ideal system for providing freedom of choice to the individual subscriber The modularity of the system makes it a competitive choice in both single and multi satellite systems in small as well as in large community networks The extensive modularity of this system makes it fully expandable in terms of both satellite positions and subscriber outputs Technical data TDM 404 TDM 406 TDM 408 Cascadable multiswitches with 16 polarities 1 terr input External power supply TDM 404 364404 TDM 406 364406 TDM 408 364408 Number of inputs 4 x SAT 4 x SAT 4 x SAT Number of outputs 4 x SAT 4 x SAT 4 x SAT Subscriber outputs 4 6 8 Connectors F con female female female Frequency range MHz 950 2200 950 2200 950 2200 Through loss cascade dB 3 0 1 4 5 1 4 5 1 Tap loss dB 2 to 4 2 1 to 5 2 1 to 5 2 Isolation dB gt 35 gt 35 ZOO Iso
238. e SC type Remarks Yagi 18 Elm Gain Ch 21 37 Ch 21 69 Yagi 18 elem 19 Triax UNIX 32 band IV V aerial UHF TRIAX UNIX aerials have been designed for UHF reception With their excellent gain and excellent front to back ratios these aerials ensure superior TV reception The aerials have been designed to ensure optimum reception even under difficult conditions Easy and uncomplicated mounting is ensured by the snap lock dipole house made of UV resistant blue plastic The balun with capacitive signal transfer from the dipole ensures matching adjustment with lower insertion loss At the same time galvanic corrosion between the different materials in contact with each other is avoided The aerials are made of salt water resistant aluminium ensuring long service life Technical data UNIX 32 UNIX 32 UNIX 32 digital digital 108750 107750 Channel 21 69 21 69 Band BIV V BIV V Elements pcs 32 32 Gain dBi 12 5 12 5 Front to back ratio dB 24 24 Beamwidth hor deg 20 20 Windload N 58 58 Weight kg 1 45 1 45 Material Alu Alu Dimensions length mm 791 791 width mm 500 500 Connector SC type F con Remarks 20 Unix 32 Elm Gain UNIX 32 elem Technical data Triax UNIX 52 band IV V aerial UHF TRIAX UNIX aerials have been designed for UHF reception and are available in a 52 element version
239. e diode DC pass Yes Yes Yes Yes Connector F con F con F con F con F con Weight kg 0 230 0 230 Dimensions Height mm 124 124 124 124 108 Depth mm 55 55 OO 55 50 Width mm 138 138 138 138 120 Remarks 37 Triax MFA kit amplifiers power supply High performance range of MFA mast amplifiers combined with the excellent IFP power supply in a attractive modern housing design both equipped with F connector qg ut Available complete kit on MFA amplifiers incl power supply MFA 402 MFA 411 340411 MFA 409 340409 MFA 410 340410 MFA 404 340404 MFA 407 340402 340407 Set consists of amplifiers MFA 302 MFA 304 MFA 307 MFA 309 MFA 310 MFA 311 power supply IFP 501 IFP 502 IFP 502 IFP 502 IFP 502 IFP 502 See specification on page amplifiers 36 36 36 36 36 37 power supply 200 200 200 200 200 200 Weight kg 0 645 0 645 0 645 0 645 0 645 0 645 Dimensions Height mm 170 170 170 170 170 170 Depth mm 78 78 78 78 78 78 Width mm 242 242 242 242 242 242 MFA 414 340414 MFA 420 340420 MFA 412 MFA 413 340412 340413 Set consists of amplifiers MFA 312 MFA 313 MFA 314 MFA 320 power supply IFP 502 IFP 502 IFP 502 IFP 502 See specification on page amplifiers 3 7 37 37 37 power supply 200 200 200 200 Weight kg 0 645 0 645 0 645 0 645 Dimensions Height mm 170 170 170 170 Depth mm 78 78 78 78 Width mm 242 242 242 242 MFA 514 340514
240. e of contents Outdoor Indoor Splitters taps TOU series HNA series 150 A TECH 5 1000 MHz 168 173 standard multimedia sat 216 220 HTA series 151 H TECH 5 1000 MHz 174 180 TD series HDA series 152 S TECH 5 2400 MHz 181 185 standard multimedia sat 221 224 HEA series 153 TDP delivery points 186 HT loudspeaker FV f con 225 accessories 154 156 TLS range of outdoor splitters 187 OPUS series HFA series 157 TLT range of outdoor taps 188 193 standard multimedia sat 226 accessories 158 Triax indoor splitters 194 195 Triax UK series 227 HEF series 159 Attenuators 196 Triax GAD series 228 229 Indoor Power inserters 197 Triax GRID series 230 231 IFE series 160 161 Power supplies 198 199 Accessories IFA series 162 163 Cables Indoor outdoor 200 205 TOU covers frames terminators 232 IFB series 164 Multi and fly leads 206 207 TD covers frames terminators 233 IE series 165 Tools and connectors 208 210 GAD covers frames terminators 234 TA Type 02 Adaptors terminators 2TV 2TV 166 isolators electrical articles 211 213 Home accessories Technical appendix Contents from A to Z Camera systems 236 237 Terrestrial antennas 242 Contents 252 257 DDU series 2
241. e quality becomes considerably increased TD Polarmount Triax SatSelect 124078 300053 DiSEqC level 1 2 Rotation angle degrees 30 60 Rotation speed degrees 1 per sec Power Stand by 50 mA Operat 200 mA Peak 350 mA Voltage VDC 13 18 Mast dimension mm 032 50 032 50 Weight kg Packing type Single pcs Single pcs Remarks F con connection Para Protection to cover LNB units on dishes Para Protection Para Protection TD and Basic Unique dish 300708 300707 Material and finish Perspex sheet and Perspex sheet and painted metal holder painted metal holder Arm dimension W x H max mm 76x45 Packing type Single pcs Single pcs Remarks Fits on all Triax TD Fits on all Triax and Basic dishes Unique dishes 95 Mounting accessories for dishes TRIAX s brackets for all your needs TRIAX has all kind of mounting brackets for dishes You will also find a complete range of different accessories everything for making a perfect mounting Triax 2561 stand Mounting accessories for dishes Triax 2561 Type J Type S Type U Universal roof Stand 50 wall bracket 127100 128050 128070 128080 300709 Material Galv steel Galv steel Galv steel Galv steel Galv steel Tube dimension mm O50 O25 O25 O25 O45 Weight kg Packing type Single pcs Single pcs Single pcs Single pcs Single pcs Remarks For mounting In
242. eceiver via SCART cable included Camera is wireless 3 Set comprising of 1 transmitting camera and 1 receiver 4 Modulator UHF channel settable via 2 digit rotary switch channels 21 thru 69 NOTE When applying additional cameras to the TCC011WL set it is important that all cameras are mounted in accordance with mounting instructions The operational range is highly dependent upon the technical environment the physical building structures at hand and other wireless equipment in use 237 Triax Domestic Distribution Unit DDU You can build home distribution systems or you can save time and material costs The DDU is an amplifier unit for the distribution of radio m satellite and terrestrial television signals around a a domestic property The unit is usually located remotely from the main area of receiving equipment The unit will receive BIII DAB BI FM UHF x2 and four IF satellite feeds from a Quad LNB The unit then distributes the above to the main TV in the lounge and 8 outlets within the property All 8 outlets carry the services from the digibox as well as radio and UHF signals and output 7 and 8 have satellite IF straight from the Quad LNB There is another IF feed which supports the second input into the Sky receiver via the uplink path The Sky receiver can be controlled by the Digital Link return path on output 1 to 6 DDU 112 unit DOWN LINK DDU Outlet Part No 30
243. ecommended for well supplied reception areas Gai ain Ratio of an antenna s reception power in its main receiving direction to receive power of a A 2 dipole at the same installation site logarithmic measure expressed in dB Angle of acceptance Angular aperture of the major lobe between the points where the gain is lower by 3 dB than its maximum value Major lobe Section of the radiation pattern in the direction of the maximum gain Side lobe Directional reception Lateral and rearward lobe shaped sections of the radiation pat The directional antenna receives signals from one main direc tern that have a lower gain than in the main receiving direction tion better than omnidirectional antennas but has poorer reception of signals from other directions Front to back ratio A directional antenna is absolutely necessary for areas Ratio of the voltage Uv in the main receiving direction to where signals are weak or in areas where a particular weak an average Ur generated on the basis of the voltages of transmitter is to be received the side lobe 2 in the back direction 180 and of the larger side lobe 1 in the rear sector 90 270 logarithmic measure expressed in dB Corresponding to a definition by the Technical Commission of the Receiving Antennas association in ZVEI 3 Antennas are suitable for ed Na the reception of digital Be terrestrial signals DVB T 242 Technical appendix 1 Basic techni
244. ed 322054 HTA 3038 LA1 line powered 322063 HTA 3038 MA1 mains powered 322066 HTA 3038 LP2 line powered 322057 HTA 3038 MP2 mains powered 322060 HTA 3038 LAZ line powered 322069 HTA 3038 MA2 mains powered 322072 Forward path Forward path bandwidth depending on diplexer modules MHz 47 862 47 862 Gain 8 dB gain switch 47 862 MHz dB 30 30 or 38 38 30 30 or 38 38 Attenuation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 amp 22 0 18 amp 22 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Linearity dB 3rd order DIN 45004 B dBuv 124 127 2nd order DIN 45004 A1 dBuV 122 124 CTB 42 ch CENELEC flat 8 dB tilt dBuV 108 5 111 110 5 113 CTB 42 ch CENELEC by 6 dB interstage att flat 8 dB tilt dBuV 108 110 110 112 CSO 42 ch CENELEC dBuV 112 114 Noise figure 47 862 MHz dB 5 6 5 5 6 5 5 6 5 5 6 5 Noise figure by 6 dB interstage attenuation 47 862 MHz dB 6 8 5 7 6 8 5 7 Return loss 40 MHz dB 18 1 5 oct 18 1 5 oct Return path Return path bandwidth depending on diplexer modules MHz 5 65 5 65 Gain dB 23 23 Attenuation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 8 0 8 Linearity dB 1 3rd order DIN 45004B dBuV 119 119 2nd order DIN 45004A1 dBuV 104 104 Noise figure dB 6 6 Gen
245. em Channel 5 6 4 elem Channel 7 8 3 elem Technical data Channel Channel Channel Channel Channel Channel Channel Channel Channel 5 6 5 6 5 6 7 8 7 8 7 8 9 11 9 11 9 11 104602 104603 100604 104622 104623 100624 104642 104643 100644 Channel 5 6 5 6 5 6 7 8 7 8 7 8 9 11 9 11 9 11 Band BIll BIII BIII BIII BIII BIII BIII BIII BIII Elements pcs 3 4 5 3 4 5 3 4 5 Gain dBi 4 5 6 0 8 0 4 5 6 0 8 0 4 5 6 0 8 0 Front to back ratio dB 16 13 15 16 13 15 16 13 15 Beamwidth hor deg 35 32 28 35 32 28 35 32 28 Windload N 29 34 38 29 34 38 29 34 38 Weight kg 0 65 0 75 0 85 0 65 0 75 0 85 0 65 0 75 0 85 Material Alu Alu Alu Alu Alu Alu Alu Alu Alu Dimensions length mm BIO 852 988 610 852 988 610 852 988 width mm 845 845 845 845 845 845 845 845 845 Connector SC type SC type SC type SC type SC type SC type SC type SC type SC type Type MTH MTH MT MTH MTH MT MTH MTH MT Remarks BIll 3 elem Ch 5 6 Gain b EEE EE Ee 11 O Ch 5 6 3 elem Ch 7 8 4 elem Ch 9 11 5 elem 13 Triax band Ili single channel aerial VHF Technical data Ch 6 8 elem Technical data Channel Channel Channel Channel 5 5 5 5 100205 100207 100229 100232 Channel 5 5 5 5 Band BIII BIII BIII BIII
246. eplaced parts if any Unless otherwise agreed the buyer will pay such additional costs that may arise if the product is situated at another place than the destination stated in the agreement or failing such information the place of delivery If the product has been changed or someone else than the seller or a repair man appointed by the seller has tried to repair the product or if the product has been subject to damages or used for unfit purposes or if installation operation and maintenance are not in compliance with the seller s stipulations the seller can refuse to remedy the deficiency free of charge Deficiencies caused by conditions for which the buyer or someone else is responsible or which are not announced until after expiration of the remedying period are not the seller s business General sales and delivery conditions The seller s responsibility does not include deficiencies arisen in materials provided by the customer or by a co producer supplier appointed by the customer or in constructions ordered or specified by him If the seller does not meet his obligations within a reasonable time the buyer can claim a proportional reduction of the purchase sum but not more than 15 of the agreed purchase sum In case of a vital deficiency the buyer can cancel the agreement by a written notice to the seller at the same time demanding compensation for his loss i e max 15 of the agreed purchase sum Above cond
247. er colour and own label branding can be supplied against a minimum quantity Te e Available in DeLuxe version with anti corrosive coating also on the feedarm and the elevation and mast bracket e Delivered in individual packaging but also available in bulk packs minimizing costs of transportation and handling TD dishes are of course manufactured according to Triax s quality standards with precision tools and robots ensuring absolute uniform and optimum geometry for perfect signal reception On TDS and TDA dishes the mast bracket and back structures are unpainted Technical data on TDA aluminium dishes TDA 54 TDA 64 TDA 78 TDA 88 TDA 110 50 x 56 cm 60 x 65 cm 70 x 78 cm 85 x 95 cm 100 x 105 cm Part No Light grey Ral 7035 123618 123718 123818 123908 Grey Ral 7030 Anthracite Ral 7016 123612 123712 123812 Red Ral 8012 123614 123714 123814 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 34 2 35 8 37 1 38 8 40 2 G T LNB 0 7 dB dB K 14 2 16 0 17 3 19 2 20 6 X polarisation dB gt 2 gt 2 gt 2 gt 27 gt 27 Offset angle degrees 26 26 26 26 26 Elevation range degrees 10 50 10 50 10 60 10 60 10 60 45 80 45 80 Reflector type F D 0 6 Offset Offset Offset Offset Offset Beam width degrees 3 7 3 1 2 6 2 0 1 8 Windload 42 m s N 323 445 619 902 1222 Material Aluminium Aluminium Aluminium Aluminium Aluminium Finish Polyest
248. er colours can be chosen depending on order size Packing methods All Triax products can be ordered packed and delivered in different ways optimizing your handling and distribution We can deliver either in single pack mini bulk or bulk packed exactly in the way that best enables you to save costs and achieve your desired results We can deliver satellite dishes as complete systems including set top boxes and LNBs and in consumer packaging And we can deliver dishes in bulk to your stock or packaging line with brackets and other components packed in bulk or as individual sets Single carton optional e Plastic plate e Colour e Wall bracket e LNB holder e LNB e Receiver Should you have other demands please ask your Triax sales contact and we will try to meet your requests 76 Technical data on TDE aluminium dishes TDE 78 Type Size 70 x 78 cm Triax TDE series of high quality dishes Heavy duty TDE 78 88 110 satellite dish especially designed for SMATV systems Easy to install Mounted in just 2 minutes Arm and bracketry made in one piece resulting in a safe and stable positioning of the LNB in relation to the reflector Secure positioning of satellite dish Newly designed LNB bracket in die cast aluminium Possibility of up to 4 LNBs with 2 different multifeed brackets Easy to read scale facilitates quick and simple adjustment of elevation angle Stable n
249. er of an antenna system according to EN 50083 2 may not exceed e 20 dB pW 39 dB uV at 75Q in the frequency range 30 950 MHz e 43 dB pW 62 dB uV at 75Q in the frequency range 950 2500 MHz Thus in conjunction with the shielding rate specified for the equipment the maximum operating level is as follows Maximum operating level e Shielding rate 39 dB uV in the 30 950 MHz frequency range e Shielding rate 62 dB uV in the 950 2500 MHz frequency range 3 3 Shielding rate The passive Triax components in this catalog meet as a minimum the shielding rates required by EN 50083 2 class B e 5 470 MHz 75 dB min e 470 950 MHz 65 dB min e 950 3000 MHz 50 dB min Class A components meet the increased requirements of EN 50083 2 e 5 300 MHz 85 dB min e 300 470 MHz 80 dB min e 470 950 MHz 75 dB min e 950 3000 MHz 55 dB min For active units the class A marking also documents compliance with EN 50083 2 A B CLASS 246 3 4 Signal to noise ratio noise factor The signal to noise ratio is the ratio of the used signal power to the noise power expressed in decibels The noise factor defines by how much the signal to noise ratio at the output of an active unit e g amplifier is less than the signal to noise ratio at the input The thermal noise level on a 75 Q resistor amounts for a bandwidth of 5 MHz TV channel and for a temperature of 293 K to approximately 2 dB uV The signal to noise rat
250. er point 4 way grey 213 322203 JXP 0T203 155 340414 MFA 314 IFP 502 38 708017 Protection grid for fan 123 322204 JXP O1204 J5 340514 MEA 314 IFP 503 24V 38 150007 QX5S Grey Double shielded 100 m Cardboard roll 202 340320 MFA 320 35 150008 QX5S White Double shielded 100 m Cardboard roll 202 322205 JXP OT205 155 322206 JXP OT206 155 340420 MFA 320 x IFP 502 38 R 340321 MFA 321 35 322207 JXP OT207 155 340322 MFA 322 36 342504 R1000 75 Ohm terminator 211 322208 JXP OT208 155 340323 MFA 323 36 342503 R75 75 Ohm terminator 211 322209 JXP OT209 155 340324 MFA 324 36 133221 Railing mount 27 322210 JXP OT210 155 340325 MFA 325 36 124225 Region 1 perf single packed 85 322211 JXP OT211 155 340327 MFA 327 36 124351 Region 1 solid single packed 85 322212 JXP OT212 155 340331 MFA 331 36 124352 Region 2 perf single packed 85 322213 JXP OT213 155 340606 MEA 606 37 124353 Region 2 solid single packed 85 322214 JXP OT214 155 340608 MFA 608 37 153400 RF 1 5 fly leads 207 322215 JXP OT215 155 340615 MFA615 7 153404 RF 10 0 fly leads 207 322216 JXP OT216 155 340625 MFA 625 37 153401 RF 2 5 fly leads 207 322217 JXP OT217 155 340651 MFA 651 37 153402 RF 5 0 fly leads 207 322218 JXP OT218 155 340101 MFC 101 49 153403 RF 7 5 fly leads 207 322219 JXP OT219 155 340102 MFC 102 49 150098 RG11LZW Double shielded 250 m roll 205 322220 JXP OT220 155 340120 MFC 120 DAB K11 12 13 TV FM 50 150062 RG11LZW Double shielded 500 m drum 205 322221 JXP OT221 155
251. er powder Polyester powder Polyester powder Polyester powder Polyester powder coat coat coat coat coat Aluminium LNB holder mm O40 O25 O40 O25 O40 O40 O40 Mast dimension mm O32 60 O32 60 O40 95 O40 95 O40 95 Wall bracket optional extra optional extra optional extra optional extra e optional extra Remarks some types available without Triax logo please contact our salesdepartment A wide range of different mounting brackets for the TD series dishes is also available see more detailed information on page 99 under mounting accessories E Wall bracket J bracket S bracket 79 Triax TDS Euroline series steel dishes TDS and TDA Euroline dishes All Euroline dishes will be delivered with painted mast bracket and back structure with pre mounted feedarm They also have a de luxe version of wingnuts Mounted and adjusted in two minutes Saving trouble and money is not only a long term consumer benefit TD dishes allow a substantial reduction in time used for mounting and adjusting 1 The elevation bracket is pre mounted and is easily fixed to the z mast with non slip mast brackets 2 A setting scale on the elevation brackets facilitates precise adjustment to the required satellite 3 The pre mounted feedarm just needs unfolding and the LNB holder with the LNB is simply clicked on Ral 8012 Ral 7035
252. eral Line power voltage VAC 24 65 24 65 Line power current mA 79820 3460 900 390 Mains power voltage VAC 175 260 175 260 Power consumption incl return path W 14 5 16 5 Dimensions WxHxD mm 200 x 180 x 82 200 x 180 x 82 Weight kg 2 2 151 Triax distribution amplifiers HDA series of mini trunk and distribution end amplifiers e Adjustable attenuators for gain amp tilt adjustment The interstage attenuation and tilt function is combined in one compact MEX module e Upgradeable with a DIBTM Dynamic ingress blocking module a solution for ingress blocking return path management and secured longer return path channel up time HTA and HDA series only Technical data on HDA series HDA 3038 HDA 3038 Type Part No LP1 MP1 amp LA1 MA1 LP2 MP2 amp LA2 MA2 HDA 3038 LP1 line powered 322027 HDA 3038 MP1 mains powered 322030 HDA 3038 LA1 line powered 322039 HDA 3038 MA1 mains powered 322042 HDA 3038 LP2 line powered 322033 HDA 3038 MP2 mains powered 322036 HDA 3038 LAZ line powered 322045 HDA 3038 MA2 mains powered 322048 Forward path Forward path bandwidth depending on diplexer modules MHz 47 862 47 862 Gain 8 dB gain switch 47 862 MHz dB 30 30 or 38 38 30 30 or 38 38 Attenuation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 amp 22
253. exed 231 347416 HTT 4 16 178 108800 Digi 6el ch 21 69 with combiner 16 Se lt 304261 Grid diplexed 231 347420 HTT 4 20 178 108201 Digi 6el ch 21 69 with wallmount 16 EEEa 304264 Grid quad 231 347424 HTT 4 24 178 339691 Digital link anthracite 240 eee 304265 Grid quad 231 347616 HTT 6 16 179 339690 Digital link silver 240 eee ga ge 304254 Grid single F female 230 347620 HTT 6 20 179 300506 DiSEqC 2x1 position hi iso 94 EEE Se 304255 Grid single F female 230 347624 HITT 6 24 179 300503 DiSEqC 2x1 priority 94 304256 Grid single F male 230 347816 HTT 8 16 179 300510 DiSEqC 2x1 diode high end DiSEqC 93 eee 304257 Grid single F male 230 347820 HTT 8 20 179 300511 DiSEqC 2x1 diode MFD 21DT DiSEqC 93 eee Ee 304250 Grid single IEC female 230 347824 HTT 8 24 179 300502 DiSEqC 2x1 position 94 ae 304251 Grid single IEC female 230 347216 HTT2 16 176 300508 DiSEqC 2x1 relais high end DiSEqC 93 eee 304252 Grid single IEC male 230 300504 DiSEqC 4x1 matrix 94 304253 Grid sinale IEC mal 230 300509 DiSEqC 4x1 diode high end DiSEqC EE da a e Se e e mae Ee 153611 IEC Female 211 133245 Double mast clamp 68 ac tnp exe 153614 IEC Female 211 304263 Grid triplexed 231 153613 IEC Mal EE E 153572 Ground isolator 5 1000MHz 212 See nae So 131092 EKA 192 wall mount alu 97 153571 Ground isolator 5 2400MHz 212 cera ae E dre Se 131094 EXA 194 wall mount alu 97 _ 153597 Grounding Block EE 210 Gea IEC cca Hades ae be 140380 Expansion bolts
254. f mast box for outdoor installation Housing is compact and has snap lock lid e Easy installation using F connectors for cable mounting and a releasable strap for mast mounting e Instructions enclosed in the housing e Can be used with single e LED indicators for TEZ easy control of installation dual and quad LNBs pi MFD 41D switch Technical data on MFD high end DiSEqC switches Type Part No MFD 21R DIGEO Zoi 300508 MFD 21D DiSEqC 2x1 300510 MFD 41D DINIZ Om 300509 DIN Z 0c 300511 MFD 21D Ter Number of inputs 2 2 4 3 No of positions Frequency range SAT MHz 950 2200 950 2200 950 2200 950 2200 Ter MHz 47 862 Switch type Relay Diodes Diodes Diodes DiSEqC control DiSEqC 1 0 and DiSEqC 1 0 and DiSEqC 1 0 DiSEqC 1 0 and tone burst tone burst tone burst Through loss dB 1 1 5 2 5 3 0 1 0 Isolation input A B dB gt 25 gt 40 gt 30 gt 35 Return loss dB gt 10 gt 10 gt 8 gt 10 gt 10 Linearity dB 1 Function s Position option band Position option band Position option Position option Control LEDs pcs 2 2 4 2 DC loop through mA 500 max 500 max 500 max 500 max Current consumption mA lt 30 lt 30 lt 30 lt 30 Temperature range EO 30 60 30 60 30 60 30 60 Dimensions H x D x W mm 106 x 43 x 120 106 x 43 x 120 106 x 43 x 120 106 x 43 x 12
255. fferent versions are available Wide range automatic gain control AGC secures right level into the distribution net High modulation error rate MER valued by means of SAW filter technology secures best possible signal quality Full range conversion DC supply for preamplifier Technical data TDH TV converter modules TV converter TV converter TV converter TDH 776 TDH 775 TDH 778 Analogue Analogue Digital Part No B G 490775 490778 D K 490776 490778 Norm L 490776 490778 Pal 490776 490778 Modulator type l L D K B G Input frequency range MHz 45 862 45 862 50 5 858 Input level GEUN 60 90 60 90 45 90 Optimum input level dBuV 55 80 55 80 55 80 Output frequency range MHz K 2 69 K 2 69 K 2 69 Output level max dBuV 105 105 95 Output level attennuator dB 0 10 0 10 0 10 Return loss MOF in output dB gt 10 gt 10 gt 10 MER MER input signal gt 36 dB dB gt 30 TV carrier wave stability kHz lt 25 lt 25 lt 4 25 Spurious signals ref pict carrier C N dB gt 60 gt 60 gt 60 Antenna input IEC female IEC female IEC female Antenna output IEC male IEC male IEC male Temperature operation C 10 50 10 50 10 50 Weight standard module kg 0 45 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 Remarks 106 TDH FM amplifier module Plug in converter modulat
256. flow TRIAX Consulting Planning Analysing Process Projecting Calculation Accept a Commis TRIAX Inst Installing After Process Your professional partner Fast delivery from our local or international warehouse Triax is of course ISO 9001 2000 certified and our products comply with all acknowledged local and This catalogue includes data international standards on all Triax TV system products also some products that are not in stock or regularly applied in your country Please ask your local dealer fora For in depth information on pricelist on the Triax products products and applications please they keep in stock contact your local dealer or visit Other products can of course www triax com where you can also be made available to you find useful information on all the One stop from our international warehouses products and applications shopping and within a short time a COE SSE Welteme to He Troan warid Tem beg rS b s y sioning ruction sales service Support Table of contents Terrestrial reception Mounting accessories Satellite reception Aerials 6 7 Masts 62 63 Dishes BI
257. for channel groups as well as wideband With their excellent gain and excellent front to back ratios these aerials ensure superior TV reception The aerials have been designed to ensure optimum reception even under difficult conditions Easy and uncomplicated mounting is ensured by the snap lock dipole house made of UV resistant blue plastic The balun with capacitive signal transfer from the dipole ensures matching adjustment with lower insertion loss At the same time galvanic corrosion between the different materials in contact with each other is avoided The aerials are made of salt water resistant aluminium ensuring long service life UNIX 52 UNIX 52 UNIX 52 UNIX 52 UNIX 52 UNIX 52 UNIX 52 UNIX 52 digital digital digital 108751 108752 108753 107770 107766 107767 107776 Channel 21 40 21 50 21 69 21 40 21 50 21 69 21 69 Band Group Group BIV V Group Group BIV V BIV V Elements pcs 52 52 52 52 52 52 52 Gain dBi 14 5 14 5 14 5 14 5 14 5 14 5 14 5 Front to back ratio dB 20 20 20 20 20 20 20 Beamwidth hor deg 15 15 15 15 15 15 15 Windload N 96 96 96 96 96 96 96 Weight kg 1 72 1 68 1 63 1 72 1 68 1 63 1 63 Material Alu Alu Alu Alu Alu Alu Alu Dimensions length mm 1512 1410 1297 1512 1410 1297 1297 width mm 500 500 500 500 500 500 500 Connector SC type SC type SC type F con F con F con F con Remarks Unix 52 Elm Gain UNIX 52 elem 21
258. fter receipt of the products If the complaint is not made within the time limit stated the buyer loses his right to put forward a claim Complaints of discrepancies in quantity and damages to the product should be made immediately to the carrier if any and to the seller Otherwise the buyer loses his right to complain of such faults 13 RESPONSIBILITY FOR SHORTCOMINGS Provided that the agreed terms of payment are kept and that complaints are made in due time the seller will remedy any shortcomings that turn up during a period from 12 months from the delivery date The responsibility does not comprise deficiencies caused by factors arisen after the risk has passed over to the buyer Remedy is only made by adjustment repair or replacement of parts of the product or its com ponents according to the seller s option Wages paid for dismounting and mounting will not be refunded If dismounting and mounting should af fect more than the product such work and costs are irrelevant to the seller as well The buyer has to send the seller a written complaint with details of the deficiency without undue delay The complaint should be made immediately if there is reason to believe that damages might be involved If the buyer does not advise the seller of a deficiency within the time limit stated the buyer will lose his right to make a Claim Return of repaired parts or return of the product is paid by the seller who takes over r
259. ful reliable and easy to install HFA distribution amplifiers Triax distribution amplifiers With the HFA series of broadband distribution amplifiers both the installer and the network operator obtain all the benefits of a quality product Reliability and a long lifetime quick installation effective shielding and the option to use the network for all conceivable interactive services Technical data on HFA distribution amplifier mains powered HFA 602 324602 HFA 603 324603 b HFA 604 324604 Forward path Frequency range MHz 47 73 87 862 47 73 87 862 47 73 87 862 depending on module Gain adjustable dB 22 30 40 Attenuation dB 0 20 0 20 0 20 Noise figure dB lt 8 5 typical 7 5 lt 7 5 typical 6 5 lt 7 0 typical 6 0 Linearity dB 1 0 1 0 1 0 Equalization dB 0 18 0 18 0 18 Output level 60 dB 3 order DIN 45004B dBuvV 118 118 118 60 dB 2 order DIN 45004A1 dBuvV 112 112 112 60 dB CTB dBuV 101 101 101 60 dB CSO dBuV 101 101 101 Return loss input 1 5 dB octave dB gt 14 40 MHz gt 14 40 MHz gt 14 40 MHz min 10 min 10 min 10 Return loss output 1 5 dB octave dB gt 14 40 MHz gt 14 40 MHz gt 14 40 MHz min 10 min 10 min 10 Return path Frequency range MHz 5 30 5 55 5 30 5 55 5 30 5 55 depending on module or 5 65 or 5 65 or 5 65 Gain adjustable dB passive 1 0 passive
260. g a satellite cable or terrestrial channel A complete system is simply built with the main sub unit system where 1 basic AA unit and 4 sub units can be coupled in cascade and operate as one integrated headend with 30 channels All communication between modules and the basic units is done via a high speed data bus and by means of this modern communication structure important features like operating the system software updates and remote access have become extremely simple For maximum flexibility a one module basic TDH SA unit is also avaiable Technical data TDH 700 main unit TDH 700 TDH 701 TDH 791 TDH 700 Main unit Sub unit SA cabinet SA controller 490790 490791 301791 301700 Number of channels Pcs 6 6 1 Output frequency range MHz 47 862 47 862 depending on module Max output level 6 combined ch max 60 dB IMD dBuvV 105 105 Output level stability dB lt 1 lt 1 Adjustment dB 10 10 depending on module Test point dB 30 30 Return loss output Tv in tv out module RF in dB gt 10 gt 10 depending on module Impedance Ohm 75 75 Remote control Yes PC interface functions Yes via controler Software download 9 pin RS 232 female via controler RS 232 female Modem connector 9 pin RS 232 male via controler RS 232 male Main sub unit connector USB A B cable USB A B cable USB A B cable USB A B cable Wall rack bracke
261. g tool for F connectors The plastic handle gives you a good grip of the connector and is more convenient to work with than the metal types of mounting tools Especially for one piece and compression type of F connectors Part No 153632 Torque wrench spanner The spanner ensures a proper installation in accordance with SCTE standards minimizing the risk of heavy screening leakage When using F connectors outdoors SCTE recommends a torque of 3 4 5 6 Nm Tools for professional cable mounting Tools for stripping crimping and mounting The most efficient and stable connection between cable and connector is obtained when crimping is done in one swift operation no re crimping and with a tool in the exact right size Triax s range of F connector tools is easy to use and reduces stripping crimping and mounting to a few quick and precise operations Part No 153605 Crimp tool universal is for two piece F connectors Part No 153609 CRP 106F crimp tool is for 324 8 2 mm and 475 11 9 mm one piece F connectors typically used with RG 11 cables RG 11 cables RG 6 cables K Part No 153602 Part No 153601 Stripping tools With rotary cable strippers preparation of cable is reduced to a single operation resulting in precise stripping in the dimensions matching exactly with the connector The non expensive stripping tools are pre adjusted for RG 6 and RG 11 cables respective
262. ge MHz 47 68 1 channel in BI 87 5 108 174 230 1 channel in 174 230 47 68 BIII 174 230 with limiter Gain dB 20 20 19 5 25 25 25 Noise figure VHF dB 1 6 3 0 1 8 1 5 3 0 1 5 Output level 60 dB IMD ZEON 122 115 122 110 115 110 Max input level dBuV 100 Numbers of in output 1 1 1 1 1 1 1 1 1 1 1 1 Voltage VDC 24 24 24 24 24 24 Power mA 100 40 100 30 40 30 DC throughpower No No No No No No Connector PG 11 PG 11 PG 11 PG 11 PG 11 PG 11 Weight kg 1 322 1 322 1 322 1 322 1 322 1 322 Dimensions Height mm 146 146 146 146 146 146 Depth mm 80 80 80 80 80 80 Width mm 194 194 194 194 194 194 Remarks Low noise Low noise Low noise Low noise Low noise Low noise 32 Triax pre amplifiers series 8000 80000 Series 8000 is available in HF tight painted aluminium housing in splash proof design with cable entry by means of RG11 connectors The series 8000 amplifiers feature low noise figures high gain and high output voltage Technical data on series 8000 low noise pre amplifiers with PG11 connectors 80065 81065 81065K 81065K 80065K 80065K UHF UHF Ch 21 46 Ch 47 68 Ch 21 46 Ch 47 68 325800 325804 325824 325825 325820 325821 Input frequency range MHz 470 862 470 862 1 UHF channel 1 UHF channel 1 UHF channel 1 UHF channel with limiter with limiter with limiter Gain dB 24 24 24 24 24 24 Noise figure VHF dB 1 8 1 4 1 8 1 4 1 8 1 4 1 8 1 4 1 8 1 4 1 8 Output level 60 dB IMD ZEON 109 109 115 115
263. gle packed Ral 7016 78 123831 TMB 88 Ral 7035 3 pcs Carton box pr unit 82 Ge ge E Se conirorer 706 122610 TDS 64 Single packed Ral 7030 78 311169 TMC 2528 group combiner ch 2 25 ch 28 69 e a Se Seko TE be 122618 TDS 64 Single packed Ral 7035 78 311167 TMC 2831 group combiner ch 2 28 ch 31 69 51 awe ee Fe waster eee mono Mowe __ _ 429725 TDS 78 Bulk Ral 7016 100 pcs pll 82 311164 TMC 3335 group combiner ch 2 33 ch 35 69 51 490703 TDH 703 Master DVB S stereo module Cl 101 r 490704 TDH 704 SI DVB S T 103 122724 TDS 78 Bulk Ral 7030 100 pcs pll 82 311162 TMC 3537 group combiner ch 2 35 ch 37 69 51 ave mene 122717 TDS 78 Bulk Ral 7035 100 pes pll 82 _ 311153 TMC 3739 group combiner ch 2 37 ch 39 69 51 490705 TDH 705 Slave DVB S T stereo 103 490712 TDH 712 Master DVB T dule Cl 102 122754 TDS 78 Bulk w single Ral 7016 100 pcs pll 82 311166 TMC 3941 group combiner ch 2 39 ch 41 69 51 eea ea SEE Gere mo i a bea 122737 TDS 78 Bulk w single Ral 7030 100 pcs pll 82 311154 TMC 4648 group combiner ch 2 46 ch 48 69 51 Ere 122749 TDS 78 Bulk w single Ral 7035 100 pcs pl 82 _ 311168 TMC 5052 group combiner ch 2 50 ch 52 69 E 490714 TDH 714 Master DVB T mono module FTA 102 l 490715 TDH 715 Master DVB T st dule FTA 102 122764 TDS 78 Bulk w single Ral 8012 100 pcs pll 82 311157 TMC 5153 group combiner ch 2 51 ch 53 69 51 aster ve Stereo IE E 121761 TDS 78 Single EUROLINE Ral 7016 80 311155 TMC 5355 group combiner ch 2
264. gt 20 0 gt 20 0 Return loss tap 5 40 MHz dB gt 30 0 gt 35 0 gt 35 0 gt 40 0 40 1000 MHz dB gt 25 0 gt 25 0 gt 30 0 gt 32 0 1000 1750 MHz dB gt 25 0 gt 25 0 gt 30 0 gt 30 0 1750 2150 MHz dB gt 20 0 gt 22 0 gt 25 0 gt 25 0 2150 2400 MHz dB gt 18 0 gt 20 0 gt 22 0 gt 22 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass In Out In Out In Out In Out Connectors F connector F connector F connector F connector Certification CE CE CE CE Impedance Ohm 75 75 75 75 Weight kg 0 063 0 063 0 063 0 063 Dimensions h x d x w mm 50x16x74 50x16x74 50x16x74 50x16x74 183 Triax taps STT series 5 2400 MHz STT 4 12 348412 STT 4 16 348416 STT 4 20 348420 STT 4 24 348424 STT 4 30 348430 Frequency range MHz 5 2400 5 2400 5 2400 5 2400 5 2400 Outputs pcs 4 4 4 4 4 Insertion loss in out 5 40 MHz dB lt 4 7 LAT lt 1 2 lt 2 1 lt 1 2 40 1000 MHz dB lt 4 7 lt 3 2 lt 1 7 lt 3 2 lt 1 7 1000 1750 MHz dB aie lt 4 2 lt 2 2 lt 4 2 lt 2 2 1750 2150 MHz dB lt 6 2 lt 5 2 lt 3 2 lt 5 2 lt 3 2 2150 2400 MHz dB lt 7 0 lt 6 0 lt 4 0 lt 6 0 lt 4 0 Tap loss 5 40 MHz dB 12 0 2 0 15 0 41 5 20 0 41 5 24 0 1 5 30 0 1 5 40 1000 MHz dB 12 0 1 5 15 0 41 5 20 0 41 5 24 0 1 5 30 0 1 5 1000 1750 MHz dB 12 0 1 5 15 0 41 5 20 0 41 5 24 0 1
265. gt 22 0 gt 19 0 40 470 MHz dB gt 22 0 gt 20 0 gt 22 0 gt 22 0 gt 20 0 470 750 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 20 0 750 860 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 18 0 860 1000 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 18 0 gt 17 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No Connectors F connector F connector F connector F connector F connector Certification CE CE CE CE CE Impedance Ohm 75 75 75 75 75 Weight kg 0 138 0 138 0 138 0 138 0 131 Dimensions h x d x w mm 38x 16x161 38x 16x161 38x 16 x 161 38 x 16 x 161 36 x28 x 115 172 CLASS GRADE 1 Triax taps ATM series 5 1000 MHz ATM 4 12T ATM6 12T ATM 8 12T 346413 346617 346812 Frequency range MHz 5 1000 5 1000 5 1000 Outputs pcs 4 6 8 Tap loss In Tap 1 2 5 40 MHz dB 12 5 1 0 12 5 41 0 12 5 1 0 40 470 MHz dB 12 5 1 0 12 5 41 0 12 5 1 0 470 750 MHz dB 12 5 41 2 12 5 41 2 12 5 1 2 750 860 MHz dB 12 5 1 5 12 5 41 5 12 5 1 5 860 1000 MHz dB 12 5 1 5 12 5 41 5 12 5 1 5 Tap loss In Tap 3 4 5 40 MHz dB 12 0 1 0 13 5 41 2 13 5 4 1 2 40 470 MHz dB 12 0 1 0 13 5 41 2 13 5 41 2 470 750 MHz dB 12 0 1 2 13 5 41 5 13 5 4 1 2 750 860 MHz dB 12 0 1 5 13 5 42 0 13 5 1 5 860 1000 MHz dB 12 0 2 0 13 5 42 0 13 5 1 5 Tap loss In
266. h 31 32 TDH Channel filter 110 324587 ASC 011 Chassis for 10 modules 119 312150 75 XY 52 301333 Ch 33 34 TDH Channel filter 110 324599 ASL 030 HF bridges 75 Ohm IEC 119 311304 7508 BIII ch 8 55 ee 301335 Ch 35 36 TDH Channel filter 110 324598 ASR 075 75 Ohm IEC termination 119 311301 750X BI 55 301337 Ch 37 38 TDH Channel filter 110 324593 ASU 040 ch21 69 att 0 18dB 40dB gain 119 311303 750x DII 55 301339 Ch 39 40 TDH Channel filter 110 324594 ASU 050 ch21 69 att0 18dB 50dB gain 119 311140 75132 Combiner 56 301341 Ch 41 42 TDH Channel filter 110 324590 ASV 137 E2 E4 att 0 18dB 37dB gain 119 316110 753343 attenuators 196 301343 Ch 43 44 TDH Channel filter 110 324591 ASV 237 87 5 108 MHz att 0 18dB 37dbgain 119 325830 8000 1 BI amp 32 324592 ASV 337 E5 E12 att0 18dB 37dB aain 119 301345 Ch 45 46 TDH Channel filter 110 325857 8000 1K BI channel 32 300570 ATB 2150 Sari EEE g 128 301347 Ch 47 48 TDH Channel filter 110 325835 8000 2A BII 32 346413 ATM 4 12T p 173 301349 Ch 49 50 TDH Channel filter 110 325838 8000 3 BIll 32 346617 ATM 6 12T 173 301351 Ch 51 52 TDH Channel filter 110 325856 8000 3K BIII channel 32 346812 ATM 8 12T 173 301353 Ch 53 54 TDH Channel filter 110 325800 80065 UHF amp 33 346002 ATS 2 168 301355 Ch 55 56 TDH Channel filter 110 325820 80065K amp Ch 21 46 33 346003 ATS 3 168 301357 Ch 57 58 TDH Channel filter 110 325821 80065K amp Ch 47 68 33 346010 ATS 33 168 301359 Ch 59
267. h saddle and clamp connections Mast amplifiers with saddle and clamp connections TMA UHF wideband amplifier TMA 18W U TMA 28W U TMA 12 2 U TMA 24W TMA 24W 2W U 20W U 333324 333325 333326 333570 333571 Input 1 Channel 21 69 21 69 21 69 21 69 21 69 Gain dB 18 28 2x12 25 14 24 Noise figure dB lt 3 0 lt 3 0 lt 4 5 lt 3 0 lt 4 0 Input 2 Channel BI BII BIII BI BII BIII Gain dB 2 0 10 20 Noise figure dB lt 3 0 Input 3 Channel Gain dB Noise figure dB Max output voltage 60 dB IMA dBuvV 105 105 2x98 105 105 Numbers of in output 1 1 1 2 1 2 2 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 Power mA 20 30 25 30 30 DC throughpower No No No No No No No Connector S amp C S amp C S amp C S amp C S amp C Weight kg 0 125 0 125 0 125 0 125 0 125 Dimensions Height mm 69 69 69 69 69 Depth mm 55 55 55 55 55 Width mm 94 94 94 94 94 Remarks Wideband Wideband Wideband Multiband Multiband 46 Triax UHF single channel amplifiers TRIAX s SCA masthead amplifier TRIAX s UHF single channel amplifier series includes a range of amplifiers with 1 input on 20 dB gain 1 passive rest VHF UHF input and 1 output e New attractive design in blue amplifier housing e Snap lock closure system and rubber grommets ensure a high degree of waterproofing Input channel selectivity Single channel with 20 dB gain Rest VHF UHF input with 1 dB Switchable DC on rest UHF 12
268. he performance of the agreement made Failing an agreement all documentation handed over should be returned to seller and also in that case no copying or general use of the material can be made nor must it be brought to the knowledge of a third party The seller is not responsible for the buyer s selection of the product including compatibility of the product its use and results unless the contract explicitly refers to these The seller undertakes no responsibility for the buyer s selection of potential supplementary equipment and service requested for use with the product as well as application and results of same The seller reserves the right to modify his products without notice as far as such modifications do not cause major restrictions of the applications 4 PRICE ALTERATIONS The seller reserves the right to alter prices in case of major changes of rates of exchange increased prices for raw materials political events or other conditions which the seller cannot control unless a written agreement states that the seller is not entitled to make such reservation 5 PASSING THE RISK The risk for the product is passed upon delivery unless otherwise agreed in writing Such agreements are made in accordance with Incoterms 90 terminology 6 TIME OF DELIVERY DELAYS The agreed time of delivery is only approx imdte and subject to full approval of the contents of the agreement for instance accepted drawings
269. i 22 kHz 0 6 2 Hi 22 kHz 0 6 2 Control LEDs for service purpose Yes Yes Yes Colourcoding of IF and TER inputs Yes Yes Yes Temperature range oC 0 50 0 50 0 50 Max current mA 500 500 500 Dimensions H x D x W mm 145 x 138 x 36 234 x 138 x 36 234 x 138 x 36 143 Triax Districom 4000 multiswitches TDC DiSEqC switches DiSEqC switches are used for switching between 2 3 or 4 satellite positions In the Districom 4000 system it is extremely easy to plug in the switches and later change the configuration when the needs of a subscriber change The product range includes DiSEqC switches with 2 3 and 4 inputs to allow subscribers differentiated access based on the number of available satellites One series TDC 200 300 or 400 is for use in completely new systems combining satellite signals and terrestrial signals in one cable Technical data TDC Sat DiSEqC switches TDC 200 TDC 300 TDC 400 TDC 200 TDC 300 TDC 400 364200 364300 364400 Satellite inputs via TDM module 2 3 4 Terrestrial inputs via TDM module via SATA via SATA via SATA Input connectors F quick F con male male male Output connector F con female female female Frequency range SAT MHz 950 2200 950 2200 950 2200 Frequency range TER MHz 5 862 5 862 5 862 Pass through SAT Loss dB O 2 D 2 D 2 Pass through TER Loss dB 3 1 3 1 3 1 Attenu
270. i m a A o a EEE MEE Li BEE A B KK A i BIO Ch 02 04 05 Combi 13 Ch 5 12 Ch 21 69 Gai Ch 21 60 Ch 2 4 5 12 G Combi 12 Ch 02 04 05 12 Combi 1 6 Combi 13 Combi 12 25 Triax Combi aerial VHF UHF The combined aerials are different from previous aerials in many respects such as e Improved UHF VHF gain e Increased number of elements to provide the aerials with even more gain e New balun which ensures improved matching e Easy to install e Elevation type mast brackets included Combi 57 Combi 20 Combi 27 Window Technical data Combi 20 Combi 27 Combi 27 Combi 57 Window Mast 108694 108687 108688 108696 Channel 5 12 21 69 5 12 21 69 5 12 21 69 5 12 21 69 Band BIII BIV V BIII BIV V BIII BIV V BIII BIV V Elements pcs 5 15 4 23 4 23 5 52 Gain VHF dBi 6 0 7 0 7 0 8 0 UHF dBi 11 5 13 0 13 0 14 5 Front to back ratio hor dB 12 0 17 0 17 0 17 0 ver dB 17 0 25 0 25 0 25 0 Beamwidth hor deg 35 31 31 31 ver deg 25 22 22 15 Windload N 56 72 72 146 Weight kg 1 00 1 80 1 80 2 90 Material Alu Alu Alu Alu Dimensions length mm 815 490 490 1725 width mm 760 880 880 880 Connector SC type SC type SC type SC type Packing size 1 1 1 1 Type MTH MTH MTH MTH Combi 20 Ch 5 12 Ch 21
271. ic paint to protect from elements Neoprene sealed and nickel plated brass for all 5 8 port entry and taps F f port Provides uninterrupted power and RF service when the faceplate is removed TLS 102 TLS 103 TLS 103 S TLT 108 TLT 112 TLT 116 80225 80226 80263 80236 80237 80238 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 1 Outputs pcs 2 3 3 2 2 2 Insertion loss 5 40 MHz dB lt 2 4 lt 1 4 lt 1 4 40 470 MHz dB lt 2 7 lt 1 6 lt 1 6 470 750 MHz dB lt 3 3 lt 1 8 lt 1 8 750 862 MHz dB lt 3 8 lt 2 1 lt 2 1 Tap loss output 1 2 3 5 40 MHz dB lt 3 9 lt 3 9 lt 7 2 lt 5 7 lt 5 7 8 0 1 0 12 0 41 0 16 0 1 0 40 470 MHz dB lt 4 1 lt 4 2 lt 7 5 lt 6 1 lt 6 1 8 0 1 0 12 0 1 0 16 0 1 0 470 750 MHz dB lt 4 5 lt 4 5 lt 8 0 lt 66 lt 6 6 8 0 1 0 12 0 1 0 16 0 1 0 750 862 MHz dB lt 4 8 lt 4 6 lt 8 5 lt 7 5 lt 7 5 8 0 1 5 12 0 41 5 16 0 1 0 Isolation out tap 5 40 MHz dB gt 22 0 gt 22 0 gt 25 0 gt 22 0 gt 24 0 gt 25 0 40 470 MHz dB gt 27 0 gt 27 0 gt 27 0 gt 24 0 gt 24 0 gt 24 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 22 0 gt 23 0 gt 25 0 750 862 MHz dB gt 25 0 gt 23 0 gt 22 0 gt 22 0 gt 23 0 gt 25 0 Isolation tap tap 5 40 MHz dB 40 470 MHz dB 470 750 MHz dB 750 862 MHz dB Return loss o
272. iers IFA distribution amplifiers with 5 30 and 5 65 MHz return path e compact indoor distribution amplifier in a modern white shielded plastic housing for indoor use only e Recommended for low channel density MATV D IFA amplifier housing Technical data on IFA distribution amplifiers TYPE IFA 212 IFA 213 Part No 339212 339213 Forward path Frequency range MHz 47 862 87 862 Gain 47 or 87 MHz 862 MHz dB 0 20 0 20 Noise figure dB lt 6 0 lt 6 0 typical 4 5 typical 5 5 Linearity dB 1 5 15 Slope dB Equalizer dB 0 18 0 18 Outputs pcs 1 1 Output level 60 dB 3 order DIN 450048 dBuvV 112 0 112 0 60 dB 2 order DIN 45004A1 dBuvV 104 0 104 0 60 dB CTB 1 dBuV 96 0 96 0 60 dB CSO 1 dBuV 96 0 96 0 Return loss 1 5 dB octave dB gt 14 47 MHz gt 12 3 87 MHz Return path Frequency range MHz 5 30 5 65 Through loss dB 1 0 1 0 Linearity dB 1 0 1 0 General Power supply VDC 230 10 230 10 Power consumption W 3 0 3 0 Shielding efficiency VHF dB 15 15 Shielding efficiency UHF dB 65 65 Connectors F connector F connector Certification CE CE Impedance Ohm 75 75 Operation temperature range C 0 50 0 50 Weight kg 0 400 0 475 Dimensions h x d x w mm 61x44x118 61x44x118 1 DIN EN 50083 Part 3 CTBA Composite triple beat ratio 60 dB IMR CENELEC raster 42 channels 163 Triax indoor bo
273. ifier 30 dB 157 150021 Coax QX4S Grey 200 m rolls 202 153711 F conn 6dB attenuator 196 324604 HFA 604 Distribution Amplifier 40 dB 157 150053 Coax QX4S White 100m 202 153608 F connector Wrench Hexagonal 209 Se 322109 HNA D LPE Line powered E2000 150 150022 Coax QX4S White 200 m rolls 202 153204 F Crimp 3 7 6 4 210 322103 HNA D LPS Line powered SC APC 150 150055 Coax QX5 Grey 100m 202 153201 F Crimp 4 9 8 4 210 399112 HNA D MPE Mai d E2000 150 150056 Coax QX5 White 100m 202 153203 F Crimp 5 1 8 4 210 MFE Maing powered 7 322106 HNA D MPS Mains powered SC APC 150 153038 Coax RZ20 Female 211 153211 F Crimp 5 1 8 8 210 322121 HNA E LPE Mains powered E2000 150 153033 Coax RZ20 Male 211 153240 F Crimp 5 3 8 4 210 322115 HNA E LPS Line powered SC APC 150 108681 Combi 1 6 ch 2 4 UHF 25 153231 F crimp 7 6 11 7 210 322124 HNA E MPE Mai d E2000 150 108936 Combi 12 BIII UHF 25 153230 F Crimp for RG 11 25 pcs 210 GE da Mains GEO Zuz bea 108937 Combi 12 BIll UHF 25 153200 F Crimp For RG 6 100 pcs 210 pada ne Mains powered r 108692 Combi 13 ch 2 12 21 69 25 153202 F Crimp with rubber gasket for RG 6 100 210 303492 HT 02 225 108684 Combi 2 10 ch 3 4 UHF 25 153612 F Female 211 303493 HT 03 225 108682 Combi 2 10 ch 2 UHF 25 100184 FM 5 el stereo 10 322063 HTA 3038 LAT Li d 151 108694 Combi 20 ch 5 11 21 69 26 108951 FM indoor Aerial 30 u ee T powere o 108687 Combi 27 ch 5 12 UHF Windowmount 2
274. igh band GHz 10 6 10 6 10 6 10 6 Frequency stability MHz 3 0 1 40 60 C 2 5 1 40 60 C 2 5 1 40 60 C 2 5 1 40 60 C Phase noise room temperature DBc Hz 60 1 kHz max 60 1 kHz max 60 1 kHz max 50 1 kHz max DBc Hz 80 10 kHz max 80 10 kHz max 80 10 kHz max 75 10 kHz max DBc Hz 100 100 kHz max 100 100 kHz max 100 100 kHz max 95 100 kHz max Conversion performance room temp Conversion gain typ dB 56 56 56 56 max dB 62 62 62 62 Gain variation over operating band dB 5 p p typ 5 p p typ 5 p p typ 5 p p typ Gain flatness across 26 MHz segm dB 1 0 typ 1 0 typ 1 0 typ 1 0 typ Spurious level dBm 60 max 60 max 60 max 60 max Noise figure typ dB 0 3 0 3 0 3 0 3 max dB 0 6 0 6 0 6 0 6 Image rejection dB 40 min 40 min 40 min 40 min Cross polarization isolation dB 25 typ 20 min 25 typ 20 min 25 typ 20 min 25 typ 20 min Return loss at output dB 10 0 typ 10 0 typ 10 0 typ 10 0 typ Power requirements DC current consumption typ mA BO typ 110 max 150 typ 180 max 150 typ 200 max 190 typ Operating voltage Vertical VDC 10 5 14 5 10 5 14 5 10 5 14 5 10 5 14 5 Horizontal VDC 15 5 21 15 5 21 15 5 21 15 5 21 Band switching Low band Hz D 0 D High band KHz 22 4 22 4 22 4 Operating temperature range C 40 60 40 60 40 60 40 60 Dimen
275. io SAT Return TOU DDU 4 way 304115 TV Radio SAT Return Frequency range TV MHz 47 68 254 862 47 68 254 862 47 68 254 862 47 68 254 862 47 68 254 862 Radio MHz 87 5 230 87 5 230 87 5 230 87 5 230 87 5 230 SAT Il MHz 950 2150 950 2150 950 2150 950 2150 Return MHz DC 2150 DC 862 Tap loss TV dB lt 1 5 lt 1 5 lt 1 5 lt 1 5 dd Radio dB lt 2 5 lt 2 5 lt 2 5 lt 2 5 lt 3 0 SAT Il dB lt 3 0 lt 3 0 lt 3 5 lt 4 0 Return dB lt 2 0 lt 4 0 Connectors TV lIEC male lIEC male lIEC male lIEC male lIEC male Radio lIEC female lIEC female lIEC female lEC female lIEC female SAT F female F female 2 x F female Return F female lIEC female DC through In SAT V mA on TV Standards CE EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 75 75 Weight kg 0 250 0 250 0 250 0 250 0 250 Dimensions w x h x d mm 86x31 x 86 86 x 31 x 86 86 x 31 x 86 86 x 31 x 86 146 x 37 x 86 Remarks 227 Triax GAD series of tv radio outlets GAD outlet housing Technical data on GAD outlets TYPE GAD 215 GAD 247 GAD 256 GAD 269 GAD 274 Part No terminated loop through terminated terminated terminated excl cover and frame 1 pcs 023215 023247 023256 023269 023274 Outputs TV radio DAB TV radio DAB TV radio DAB TV radio DAB _ TV radio DAB Return SAT SAT Return SAT SAT 2 x SAT Frequency range Return MHz 4 30 4 30
276. io of the received signal is the decisive factor for the video quality of a TV set See below The signal to noise ratio at the output of an individual ampli fier for ideal i e noise free input signal can be determined as follows Operating level at the output gain noise factor noise level Example An amplifier with the following output parameters 94 dB uV operating level 21 dB gain and 7 dB noise factor The signal to noise ratio at the output of an individual amplifier would then be 94 dBuV 21 dB 7 dB 2 dBuVv 64 dB 3 5 Signal to noise ratio noise picture quality Signal to noise Noise Picture quality ratio gt 46 dB invisible very good 37 dB visible good but not interfering 30 dB clearly visible unsatisfactory interfering lt 26 dB dominant compared unusable to required signal Technical appendix 4 Earthing and equipotential bonding cables EN 50083 1 specifies the following earthing and equipential bonding cables for antenna systems Earthing cables Miera Cross section Condition Example Copper gt 16 mm gt 4 6 mm bare or insulated Koka Aluminium gt 25 mm gt 5 7 mm bare indoors only or insulated Aluminium gt 50 mm gt 8 0 mm wrought alloy Steel wire 8 0 mm galvanized Steel strip 2 5 xX 20mm galvanized Cable types single conductor or multi conductor but no fine wires Equipotential bonding cables
277. ion How high is the permissible output level for a CTB value A a dB above the catalogue value CTB 60 dB D e output level in dB uV for CTB 60 dB catalogue value a3 n e output level in dB uV for CTB 60 A dB a4 n Ni a 2 i e on an increase in the CTB requirement by d a dB the permissible output level is reduced by A a 2 dB Example figures for HEF 845 with the CENELEC spacing D output level in dB uV for CSO 60 dB 110 dB uV N Output level in dB uV for CSO 69 dB 101 dB uV N Output level in dB uV for CTB 60 dB 110 dB uV D Output level in dB uV for CTB 72 db 104 dB uV In total for CSO 69 dB and CTB 72 dB a permissible output level of 101 dB uV is to be observed b Permissible output level for channel loads deviating from catalogue specifications The individual Triax operating instructions list the maximum permissible output level for a signal to interference ratio of 60 dB for three different channel spacings up to 450 MHz 36 TV 24 FM channels up to 606 MHz 29 TV channels CENELEC raster up to 862 MHz 42 TV channels CENELEC raster Refer to Channel spacing table These conditions are very critical with respect to the develop ment of non linear distortion CTB CSO For small deviations of the actual channel spacing from the standard ones it is not necessary to reduce the output level shown in the operating instructions For larger
278. itions are the sellers maximum obligations concerning shortcomings So the seller is neither responsible for direct nor indirect losses including operational losses loss of profit as well as costs or damages etc 14 LIABILITY FOR CAUSING DAMAGES PRODUCT LIABILITY The seller is responsible for personal injuries according to the legislation concerning product liability The seller is not responsible for damages to real and personal property which occurs while the product is in the buyer s possession Nor is the seller responsible for damages to products made by the buyer or products comprising such parts Furthermore the seller is only responsible for damages to real and personal property if it can be proved that the damage is caused by mistakes or negligence made by the seller or others whom the seller is responsible for The seller is not responsible for operational losses loss of profit or other indirect losses If a product liability towards a third party has been imposed on the seller the buyer is committed to indemnify the seller to the same degree as the seller s responsibility stated in the three previous paragraphs These limitations of the seller s responsibility are not valid if the seller has shown gross negli gence If the third party claims compensation from one of the parties in accordance with this point he should advise the other party immediately The buyer is bound to let the court or arbitra
279. ixels pixels 352 x 288 352 x 288 Min illumination LUX 0 5 0 5 Built in light 11 IR Leds 11 IR Leds Auto iris electronics Sec 1 60 1 6000 1 60 1 6000 Operation conditions Weatherproof outdoor aluminium housing Power consumption mA 250 250 Operating voltage VDC 12 12 Power inserter supply incl Yes Yes Power inserter Insertion loss VHF UHF in out dB 4 4 VHF UHF in out dB 20 20 In out dB 0 1 0 1 Max current A 0 8 0 8 Dimensions camera only mm 105 x 50 x 115 105 x 50 x 115 1 AN Audio video via RCA phono cable included 4 Modulator UHF channel settable via 2 digit rotary switch channels 21 thru 69 NOTE When applying additional cameras to the TCC011WL set it is important that all cameras are mounted in accordance with mounting instructions The operational range is highly dependent upon the technical environment the physical building structures at hand and other wireless equipment in use 236 2 4 GHz wireless colour camera and camera in b w and colour with modulator e Easy and simple surveillance of buildings entrances shops garages and stables etc e For indoor or outdoor use in b w or colour e Wireless or via coax cable Wireless camera system housing Technical specifications on colour cameras TCB 007 TCB 008 TCB 017 TCC 011WL 364007 364008 364017 364011 Type Colour Colour Colour Colour
280. ks 2 holes Surface mount for all GAD outlets TYPE GDZ 465 Part No 23 465 Size mm 80 x 80 Packing size 1 pcs RF terminator for all GAD outlets TYPE GDE 270 Part No 23 270 Size mm 80 x 80 Remarks 1 pcs 234 Triax home accessories Camera systems 236 237 DDU system 238 239 Triax digital links 240 235 Triax camera systems black white Features e Solid aluminium housing e Weather resistant camera for indoor or outdoor use e Camera has built in microphone for audio monitoring e Easy plug and play installation takes only minutes e Modulator cameras available in PAL and PAL G Technical specifications on black white cameras Camera system housing TYPE TCB 003 TCB 015 Part No 364003 364015 Type B W B W TV system PAL PAL G Modulator type DSB UHF DSB UHF UHF output channel Ch 21 69 4 21 69 4 UHF output level dBuV 85 5 85 5 Output power dBm NA NA Modulation NA NA Receiver sensitivity dBm NA NA Receiver noise figure dB NA NA Output frequency range MHz 470 862 470 862 Transmission frequency GHz NA NA Operational range free field m NA NA Audio carrier MHz 6 5 5 5 Integrated mic Yes Yes S N ratio dB gt 48 gt 48 Image sensor 1 4 inch CMOS 1 4 inch CMOS Lens F 2 0 3 6 mm 90 F 2 0 3 6 mm 90 Wide angle Wide angle Resolution lines 260 260 Number of p
281. l ch 21 50 22 302637 TOU 10M 218 107768 UNIX 100el ch 21 50 with F connector 22 302687 TOU 10M 5 pcs 218 107756 UNIX 100el ch 21 60 69 with F connector 22 303670 TOU 10S 220 108756 UNIX 100el ch 21 69 22 302638 TOU 13M 218 107769 UNIX 100el ch 21 69 with F connector 22 302688 TOU 13M 5 pcs 218 107750 UNIX 32el ch 21 60 69 with F connector 20 303614 TOU 14 217 107765 UNIX 32el ch 21 69 with F connector 20 303674 TOU 14S 220 108750 UNIX 32el ch 21 69 20 300675 TOU 14S 5 pcs 220 108751 UNIX 52el ch 21 40 21 302639 TOU 17M 218 107770 UNIX 52el ch 21 40 with F connector 21 302689 TOU 17M 5 pcs 218 108752 UNIX 52el ch 21 50 21 303320 TOU IDO 216 107766 UNIX 52el ch 21 50 with F connector 21 303664 TOU 1FB 216 107753 UNIX 52el ch 21 60 69 with F connector 21 303619 TOU IE 216 108753 UNIX 52el ch 21 69 21 303629 TOU 20 217 107767 UNIX 52el ch 21 69 with F connector 21 303323 TOU 23 217 107776 UNIX 52el ch 21 69 with F connector 21 303624 TOU 4 216 453160 USB cable for TDH 0 5 m 111 302630 TOU 4DT 219 453161 USB cable for TDH 1 0 m 111 302680 TOU 4DT 5 pcs 219 VW 303627 TOU 7 217 153600 VA 20F attenuators 196 302636 TOU 8DL 218 108679 VHF UHF ch 5 12 21 69 24 302686 TOU 8DL 5 pcs 218 140037 Wall bracket 2 legs 25 50 cm 64 302631 TOU 8DT 219 140036 Wall bracket 2 legs 7 5 cm 64 302681 TOU 8DT 5 pcs 219 140047 Wall bracket 2 3 legs 25 50 cm 64 303681
282. l 13 18 volt 0 22 kHz mA 200 200 200 200 Symbol rate Mbaud lt 7 0 lt 7 0 lt 7 0 lt 7 0 Roll off factor 15 15 15 15 FEC block code RS 204 188 RS 204 188 RS 204 188 RS 204 188 Scrambling DVB ETS 300429 DVB ETS 300429 DVB ETS 300429 DVB ETS 300429 Interleaving DVB ETS 300429 DVB ETS 300429 DVB ETS 300429 DVB ETS 300429 Carrier suppression dB gt 40 gt 40 gt 40 gt 40 C N dB gt 38 gt 38 gt 38 gt 38 MER dB gt 35 gt 35 gt 35 gt 35 IQ imbalance Dgr lt 1 lt i lt 1 lt 1 Output impedance Ohm 75 15 75 75 Return loss MOD OUT dB gt 10 gt 10 gt 10 gt 10 Temperature operation C 10 50 10 50 10 50 10 50 Weight standard module kg 0 45 0 45 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 Remarks Digital measuring DCP With stuffing With stuffing 104 TDH digital QPSK FM module TDH QPSK FM module includes a receiver demodulator high quality FM stereo modulator and the built in amplifier secures the right level for directly supplying the SMATV network with high quality FM programs QPSK to FM stereo Available for FTA reception or with CI option Built in LNB supply Master slave system option for easy installation Parameter setting via TDH controller or remote High output level Can be mixed with other modules in the TDH range Technical data TDH QPSK FM module DVB S FM master DVB S FM master FM modulator DVB sl
283. l Alu Alu Alu Alu Alu Alu Dimensions length mm 2887 2332 2257 2332 2257 2257 width mm 500 500 500 500 500 500 Connector SC type SC type SC type F con F con F con Remarks UNIX 100 elem 22 UHF BB Mini Grid Accessories for stacking BB Grid Technical data Triax BB Grid band IV V aerial UHF With high gain and an excellent front to back ratio this aerial ensures perfect TV reception The reflector grid is galvanised ensuring long service life The aerial has a very even gain curve and is suitable for stacking e g on a special tube for 2 or a double tube for 4 aerials The UHF grid aerials are packed in cartons of two Ze Ter Pete Dz ag gd Ore ezz eli Ge Za I Gre EG gae Hi arie OO EE a ze Ete a UHF BB Grid 2 stacking l Ge dete E dE ESE BOR e BB BB Grid 2x 4x Mini Grid digital BB Grid BB Grid 108010 108011 108013 2 x 108013 Channel 21 69 21 69 21 69 21 69 Band BIV V BIV V BIV V BIV V Elements pcs 8 16 2x16 2x16 Gain dBi 6 0 12 0 15 0 17 5 Front to back ratio dB 28 20 25 28 Beamwidth hor deg 34 34 17 17 ver deg 20 20 20 10 Windload N 38 71 196 392 Weight kg 1 25 2 20 7 60 15 2 Material Alu Alu Alu Alu Dimensions length mm 480 840 840 1690 width mm 480 480 970 970
284. lation subscriber output dB gt 25 dB min gt 25 dB min gt 25 dB min gt 30 dB typ gt 30 GB typ gt 30 GB typ Impedance Ohm 75 75 75 Return loss dB gt 10 dB min typical gt 10 dB min typical gt 10 dB min typical Max input level dBuv 100 100 100 Output level dBuvV 100 100 100 Noise figure dB lt 8 lt 8 lt 8 Power consumption from receiver mA lt 90 lt 90 lt 90 Power supply voltage VDC 15 1 151 15 1 Power supply current mA lt 15 lt 15 lt 15 Power connector mm 2x 1 3 2x 1 3 2x 1 3 Control V 11 5 to 14 V H 16 19 V V 11 5 to 14 V H 16 19 V V 11 5 to 14V H 16 19 V Hi 22 kHz 0 6 2 Hi 22 kHz 0 6 2 Hi 22 kHz 0 6 2 Control LEDs for service purpose Yes Yes Yes Colourcoding of IF and TER inputs Yes Yes Yes Temperature range oC 0 50 0 50 0 50 Max current mA 500 500 500 Dimensions H x D x W mm 145 x 138 x 36 234 x 138 x 36 234 x 138 x 36 142 TDM 504 TDM 506 TDM 508 Technical data Triax Districom 4000 multiswitches Features of both TDM 400 and TDM 500 include e Modules with 4 6 or 8 subscriber outputs e Cascadable system with numerous configuration possibilities e DC available on all satellite distribution lines for power supply to LNBs amplifiers and other system units e Where active DiSEqC switches are needed the TDC DiSEqC switches are extremely easy to plug in and the configuration is equally easily
285. les RG 6 triple RG 11 cables use together shielded use together with tooling no e use together with 153603 with tooling no tooling no 153603 153603 Twist on connectors F con mini cable Part No 5 pcs 153049 153048 153053 153052 100 pcs 153072 153073 153074 Outer cable diametre mm 3 6 5 2 6 8 7 2 Remarks for mini cables for QX4 for QX5 for 110 KU IEC crimp connectors F grounding block TYPE IEC crimp IEC crimp TYPE F female F female Male Female block HQ block Part No 100 pcs 153030 153031 Part No 1 pcs 153597 153599 Remarks for RG 6 cables for RG 6 cables i Crimp tooling Crimp tooling no 153607 no 153607 210 Triax adaptors IEC coax connectors RZ 20 male RZ 20 female Coax male Coax female Coax male Coax female White White Angle grey Angle grey Angle white Angle white Part No 1 pcs 153033 153038 153032 153035 153042 153043 10 pcs w Se ge d IEC coax connectors high shielded TYPE Coax male Coax female Plastic cover Angle Angle White Part No 1 pcs 10 pcs 153021 153022 153017 IEC adaptors IEC male to IEC female to F female to F male to F type male F type male IEC male IEC female Part No 1 pcs 153610 153611 153613 153614 F adaptors F female F angle F female snap adaptor adaptor female Part No 5 pcs 153612 153592 153596 153593 F terminator RF terminator F R75 RTF 75 DC R75 75 R1000 PRO
286. ller save time i b ere i M a F panut KG TRAE esk pega pa i KO E T i b E i ZEZ pun nunt aes a OO hi b b B edi 3 TERE SLES EO Peri 301515 Ore asi eri dura SOIT HM ii j b era ETT errar TMS 17X8C Technical data TMS 17X16C Cascadable multiswitches with 16 polarities 1 terr input External power supply TMS 17x6C TMS 17x8C TMS 17x12C TMS 17x16C 301506 301508 301512 301516 Number of inputs 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER Number of outputs 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER Subscriber outputs 6 8 12 16 Connectors F con female female female female Frequency range SAT MHz 950 2150 active 950 2150 active 950 2150 active 950 2150 active Frequency range TER MHz 5 862 passive 5 862 passive 5 862 passive 5 862 passive Gain SAT dB 0 0 2 2 Gain TER dB 24 24 27 27 Insertion loss trunkline SAT dB 3 3 4 4 Insertion loss trunkline TER dB 4 4 4 4 Isolation LNB to LNB dB 35 30 35 35 Isolation TER to SAT dB 20 20 20 20 Isolation SAT to TER dB 30 30 30 30 Isolation cross polarisation H V dB 28 28 28 28 Isolation out out TER dB 25 25 25 25 Isolation out out SAT dB 30 30 30 30 Return loss SAT inputs dB 12 12 12 12 Return loss SAT outputs dB 12 12 12 12 Return loss TER inputs dB 8 8
287. lt 2 5 lt 2 2 D lt 0 7 lt 0 7 40 470 MHz dB lt 3 lt 2 8 lt 2 5 lt 1 2 lt 0 8 lt 0 8 470 750 MHz dB lt 3 9 lt 3 0 lt 2 8 lt 1 3 lt 0 9 lt 0 9 750 860 MHz dB lt 4 1 lt 32 lt 3 0 lt 1 5 lt 1 1 lt 1 1 860 1000 MHz dB lt 4 3 lt 35 lt 3 2 1 8 lt 1 5 lt 1 5 Tap loss in tap 5 40 MHz dB 8 0 1 0 10 0 1 0 12 0 1 0 16 0 41 0 20 0 1 0 24 0 1 0 40 470 MHz dB 8 0 1 0 10 0 1 0 12 0 1 0 16 0 41 0 20 0 1 0 24 0 1 0 470 750 MHz dB 8 0 1 2 10 0 1 2 12 0 1 0 16 0 41 0 20 0 1 0 24 0 1 0 750 860 MHz dB 8 0 1 2 10 0 1 5 12 0 1 5 16 0 41 2 20 0 1 2 24 0 1 2 860 1000 MHz dB 8 0 1 5 10 0 2 0 12 0 1 5 16 0 41 5 20 0 1 5 24 0 1 5 Isolation tap tap 5 40 MHz dB gt 22 0 gt 22 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 40 470 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 gt 25 0 750 860 MHz dB gt 24 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 gt 24 0 860 1000 MHz dB gt 23 0 gt 23 0 gt 23 0 gt 23 0 gt 23 0 gt 23 0 Isolation out tap 5 40 MHz dB gt 26 0 gt 30 0 gt 30 0 gt 28 0 gt 32 0 gt 32 0 40 470 MHz dB gt 25 0 gt 27 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 470 750 MHz dB gt 22 0 gt 25 0 gt 28 0 gt 28 0 gt 28 0 gt 28 0 750 860 MHz dB gt 21 0 gt 25 0 gt 25 0 gt 25 0 gt
288. ly Part No 153606 Mounting T tool With female thread Efficient for two piece and twist on types of F connectors Part No 153634 Cable support tool While mounting the connector this unique rubber tool gives you a good grip of the cable and with no risk of damaging the cable Support cables with dimensions 3 12 mm Part No 153608 TRIAX F key Indispensable to anyone working with F connectors 209 F connectors for drop cables One piece crimp connectors Reduces installation time as the connectors have no loose parts Designed for a very high degree of pull strength F crimp F crimp 4 9 8 4 4 9 8 1 EPA Part No 100 pcs 153200 153201 153202 153203 Remarks Without logo Rubber sealing For triple for RG 6 for RG 6 for RG 6 shielded F crimp F crimp 5 3 8 4 3 7 6 4 Part No 100 pcs 153211 153240 153204 Remarks for 110 KU for QX 5 for QX 4 1 1 7 3 TYPE RG11 RG11 EPA 7 6 11 7 7 6 11 5 Part No 25 pcs 153230 50 pcs 153231 Remarks for RG 11 Rubber sealing for RG 11 Water resistant compression types for outdoor use The tight interface effectively seals the cable and prevents corrosion from damaging the RF shielding abilities O rings inside prevent moisture ingress through the interface part of the connector F compression F compression F compression CX3 4 9 CX3 5 1 CX3 7 5 153220 153221 153222 Part No 100 pcs Remarks RG 6 cab
289. m Input F female F female F female Output F female F female F female Test point input bi directional dB 20 20 Test point output directional dB 20 bi dir 20 20 Operating conditions Max RF level EMC dBuv 113 113 113 Supply voltage V 180 253 180 253 25 65 Power consumption W 6 5 9 9 Operating temperature C 25 55 25 55 25 55 Protection class ll Protective Il Protective Il Protective Housing protection degree IP 65 65 65 Dimensions WxHxD mm 190 x 110 x 80 190 x 110 x 80 190 x 110 x 80 Weight kg 2 2 2 Packing unit 1 pcs carton box 1 pcs carton box 1 pcs carton box Reference standards Product standards safety EMC RoHS 2002 95 EG compliant EN 50083 3 Class 2 EN 50083 1 EN 60065 EN 50083 2 Yes 159 Triax distribution amplifiers Reliable flexible and cost efficient for small and middle sized buildings e ROB Return Path on Board without any external modules or pads means more flexibility and lower efforts in installation and logistics e High gain at the return path meets also special requirements in multimedia networks e C Type with jumper matrixes to switch the fix elements for attenuation equalization and to select return path or VHF operation increase the reliability and reduce the logistics e Excellent electrical performance for low cost and low power consumption Technical data on IFE series IFE 820A 323010 IFE 830 A
290. m 270 320 440 Depth outer mm 180 180 180 Mounting volume height mm 325 445 615 width mm 250 300 420 depth mm 160 160 160 Locking system lock type 2 x EMKA 1000 2 x EMKA 1000 2 x EMKA 1000 2 X single cam 2 x teardrop Door type Cabinet cover Cabinet cover Cabinet cover Cable entries pcs 2 top 2 bottom 2 top 2 bottom 3 top 3 bottom Packing Carton box Carton box Carton box kg 7 2 10 0 15 6 Remarks Backboard Backboard Backboard included included included MDU 16 lock box MDU 32 lock box 125 Triax outdoor wall cabinets 11S series of outdoor wall cabinets with 3 point security locking system and backboard Keyhole slot in each corner for easy wall mounting 3 point security locking system Safety lock protected by teardrop Stay hook on door Cable entries at the base with cover plates 11S cabinet open Technical data 11S outdoor wall cabinets TYPE 11S 6 11S 8 11S 10 Part No 160622 160822 160922 Colour Grey Ral 7030 Grey Ral 7030 Grey Ral 7030 Height outer mm 600 800 940 Width outer mm 396 516 790 Depth outer mm 240 240 325 Mounting volume height mm 447 660 800 width mm 330 450 700 depth mm 220 220 305 Locking system lock type 1 x EMKA 1000 1 x EMKA 1000 1 x EMKA 1000 locking system 3 point security 3 point security 3 point security lock protection Teardrop Teardrop
291. modulator units Technical data 1 channel modulator d A CM DIU amp CM 01V CM 01 combi type VHF type FM UHF Part No Pal 300101 300102 300116 300104 AU NZ 300107 300108 Number of inputs Pcs 1 1 1 1 Number of outputs Pcs 1 1 2 2 Number of channels Pcs 1 1 1 1FM 1 IN Modulator Type DSB Double side DSB Double side DSB Double side DSB Double side band band band band Frequency range TV MHz 175 335 470 860 470 860 88 89 2 FM MHz 470 860 TV standard Pal B Pal G Pal G Pal G Input level EON max 70 max 70 Gain from RF in to RF out 1 dB 2 RF out 2 dB 10 Output level out 1 dBuV max 80 max 80 72 77 out 2 dBuV 82 Tf Output attenuation dB 0 10 0 10 0 10 0 10 Through loss MHz 4 0 4 0 4 0 Video Input CVBS level Vpp 1 1 0 8 1 0 1 Audio input level V RMS 0 5 0 5 0 5 1 0 0 5 Power consumption W 3 3 3 Connectors F female F female F female F female Impedance Ohm 75 75 75 75 Operation voltage V AC 230 230 230 230 Operation temperature range SE O to 50 O to 50 O to 50 O to 50 Dimensions h x d x w mm 75 xX 54 x 174 75 xX 54 x 174 75 xX 54x 174 75 Xx 54 x 174 Remarks Use Scart cable Use Scart cable Use Scart cable Use Scart cable 300743 300743 300743 300743 CM 01 cable Part No 300743 Modulator cable with scart 1 5 m connector and 3 phone connectors 1 video 2 audio 117 Triax TMB programmable multi ban
292. ng new networks or upgrading an existing network and enable the step by step design and configuration of networks All share common plug in accessories to lower your cost of spare parts result ing in convenient mainteinance and reduction of operational costs Technical data on HNA D and HNA E series Block diagram TYPE HNA D series HNA E series LP amp MP LP amp MP Type Part No HNA D LPS line powered SC APC 322103 HNA D MPS mains powered SC APC 322106 HNA D LPE line powered E2000 322109 HNA D MPE mains powered E2000 322112 HNA E LPS line powered SC APC 322115 HNA E MPS mains powered SC APC 322118 HNA E LPE line powered E2000 322121 HNA E MPE mains powered E2000 322124 Forward path optical part Optical wavelength nm 1290 1600 1290 1600 Optical input power level dBm 6to 2 6to 2 Equivalent current noise 47 862 MHz pA VHz 8 6 8 6 Forward path coaxial part giak MHz 47 862 47 862 Gain switch high low dB 0 10 Interstage attenuation depending of pads dB 0 8 0 12 Interstage tilt depending of pads dB 0 8 0 8 Linearity dB 1 Output level high gain optical link specification dBuV 102 112 100 110 CTB 42 ch CENELEC 110 dBuV flat 0 dBm 4 5 OMI dB 62 62 CSO 42 ch CENELEC 110 dBuV flat 0 dBm 4 5 OMI dB 65 65 Output level low gain optical
293. o FM dB 4 0 Data dB 4 0 Tap loss TV dB 4 5 8 5 Radio FM dB 5 6 10 0 Data dB 4 5 8 5 Return path dB 1 0 4 5 Liniaritet TV radio dB 1 1 1 1 1 1 Isolation TV radio dB gt 12 gt 12 TV out dB TV data 5 65 139 862 dB gt 55 gt 20 gt 55 gt 18 Radio out dB Radio data 5 65 139 862 dB gt 55 gt 30 gt 55 gt 18 Shielding factor VHF 5 300 300 470 dB gt 85 gt 85 UHF 470 862 dB gt 80 gt 80 Data 5 65 dB gt 75 gt 75 Connectors TV IEC male IEC male Radio FM lIEC female lIEC female Data F female F female DC through TV radio data mA 100 100 CE standard EN 50083 2 EN 50083 2 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 Weight kg 0 100 0 100 Dimensions w x h x d mm 50x77x26 50 x 77 x26 Replaces type TD 272C Remarks Please refer to page 233 for cover frame and terminators 223 Triax TD200 tv amp radio outlets TRIAX TD 200 Fuga The TV radio outlets in series TD 200 have been made in FUGA design and fit into their standard range of baseplates and terminal boxes for wall flush mounting The outlets have built in radio TV filter are HF tight and have IEC specified plug outlets A TD 200 outlet TD 201R TD 201T Technical data on TD 200 special outlets TYPE TD 200 TD 201R TD 201T Terminated Terminated Terminated Part No white in bag Part No grey in bag Part No white in box 302450 302455
294. olyester powder Polyester powder coat coat coat coat Aluminium LNB holder mm O40 O25 O40 O25 O40 O40 Mast dimension mm O28 60 O28 60 O32 60 O32 60 Wall bracket optional extra optional extra optional extra e optional extra Remarks We can supply a wide range of different LNB brackets for the Basic series dishes more detailed information on page 91 under LNB brackets Basic duo block Basic multi block Basic flexi block 83 Triax DAP fibre glass dishes Fibre glass dishes are the preferred choice in some markets The most durable long term solutions in difficult environments for example in coastal areas or mountain regions Triax fulfils the demand with a series of dishes combining the resistance of glass fibre with the optimum geometry that characterises all Triax dishes whilst ensuring perfect reception quality e Available in 60 70 80 and 90 cm sizes with gains from 35 5 dB to 39 0 dB e Light grey and anthracite colour The mast bracket and the LNB holder are both easy to mount and absolutely stable with strength and stability tested in wind tunnels and through mechanical tests Technical data for DAP dishes DAP 600 DAP 800 DAP 900 DAP 901 87 x 100 cm DAP 700 DAP 701 65 x 72 cm DAP 601 58 x 61 cm 80 x 90 cm Part No DAP X00 Grey Ral 1013 126310 126313 126318 126316 DAP X01 Anthracite Ral 7016 126311 126314 126319 12631
295. on slip bracketry with 2 U brackets which ensure that the dish is kept in the right position Heavy duty wing nuts on the azimuth and elevation brackets ensure that mounting and adjustment can be done without using tools TDE 88 TDE 110 85 x 95 cm 100 x 105 cm Part No Light grey Ral 7035 123790 126385 126380 Grey Ral 7016 123792 126387 126382 Anthracite Ral 8012 123791 126386 126381 Ral 7035 Ral 7016 Frequency range GHz 10 7 12 75 10 7 12 75 10 7 12 75 Gain 11 7 GHz dBi 37 1 38 8 40 2 G T LNB 0 7 dB dB K 17 3 19 2 20 6 X polarisation dB gt 2 gt 2 gt 2 Offset angle degrees 26 26 26 Elevation range degrees 10 60 10 60 10 60 Reflector type F D 0 6 Offset Offset Offset Beam width degrees 2 6 2 0 1 8 Windload 42 m s N 619 902 1222 Material Aluminium Aluminium Aluminium Finish Polyester powder Polyester powder Polyester powder coat coat coat Aluminium LNB holder mm O40 O40 O40 Mast dimension mm O40 95 O40 95 O40 95 Wall bracket optional extra optional extra e optional extra Remarks Well designed heavy duty LNB bracket in die cast aluminium ensures stable and easy mounting more detailed information on page 90 under LNB brackets bd d Triax TDS series of standard steel dishes TD dishes Almost any dish can provide the signals needed to get a clear TV picture But will consumer satisf
296. onnector connector SAT Outlet connection Screw Screw Screw Weight kg 0 125 0 125 0 125 0 125 0 125 Dimensions w x h x d mm 50x50x26 50 x 50 x 26 50 x 77 x 26 50 x 50 x 26 50 x 77 x 26 Remarks Please refer to page 233 for cover frame and terminators FV 01 outlet les FV 02 outlet 225 Triax OPUS tv radio outlets Triax s range of OPUS TV radio outlets have improved shielding factor and are much faster to mount The newly developed design where backplate and terminals are die cast in one piece sets new standards to shielding and mechanical stability ek OPUS outlet housing Technical data on OPUS outlets 5 862 MHz TYPE TD 301 TD 304 TD 312 TD 352 TD 372 Terminated Loop through Loop through SAT Multimedia Part No white in bag 302131 302134 302132 302152 302172 Part No grey in bag 303131 303134 303132 303152 303172 Outputs TV radio TV radio TV radio TV radio TV radio SAT data Frequency range TV MHz 5 68 132 862 5 68 132 862 5 68 132 862 5 68 132 862 139 862 Radio MHz 87 5 108 87 5 108 87 5 108 87 5 108 87 5 108 SAT data MHz 950 2150 5 862 Return path MHz 5 65 Through loss TV dB 4 5 0 8 Radio dB 4 5 0 8 SAT dB Tap loss TV dB 1 0 4 5 12 0 1 0 4 5 Radio dB 1 5 4 5 12 0 1 0 5 0 SAT dB 1 0 4 5 Data dB 1 0 Liniarity TV radio SAT dB 1 1 1 1 1 1 1 1 1 1 1 1 Isolation TV radio dB gt 12 gt 12 gt 12 TV out dB
297. ons H x D x W mm 64x 111x35 64x 111x35 64x 111x35 Remarks Incl power cable Power inserter Power supply Incl power cable mounting bracket unit unit integrated mounting bracket and 1800 mm power and 1800 mm power cable with F male cable with F male 140 Triax TMS power supplies TDP 201 203 TMS 2 PSU TDP 200 Technical data TMS power supply power inserter TYPE TMS PSU TMS 2 SM PSU TMS 2 PSU Part No EU plug 336195 300277 300273 Part No UK plug 336196 Number of outputs 1 1 1 Inputs 230 V 1 1 1 Connectors F con female female female Input voltage V AC 96 to 250 96 to 250 96 to 250 Frequency range Hz 47 63 47 63 47 63 Max current A 1x 0 6 1 x 0 6 1x 1 2 Output voltage VDC 15 0 5 18 0 5 18 0 5 Supply power W 12 12 12 Cable length from supply mm Colourcoding of IF and TER inputs Temperature range oC 0 50 0 50 0 50 Dimensions H x D x W mm Remarks Power adaptor unit Power adaptor unit Power adaptor unit Districom power supply power inserter pane TDL 200 power cable lo Technical data with connectors E TYPE TDP 200 TDP 201 TDP 203 Part No EU plug 364020 364023 364024 Part No UK plug Number of outputs 2 1 2 Inputs 230 V 2 1 2 Connectors TDL 200 TDL 200 TDL 200 power cable power cable power cable Input voltage V AC 180 to 240 180 to 240 180 to 240 Frequency rang
298. or and amplifier module The TDH 772 is e g a FM amplifier module for the TDH headend With this module it is possible to obtain the right professional insertion and amplification of the terrestrial FM signal in the distribution network Dire TDH 772 Amplifier Technical data TDH FM converter modulator and amplifier modules TYPE TDH 772 FM FM amplifier Se Part No 490772 Modulator type FM Stereo Input frequency range MHz 87 5 108 0 Gain dB 9 44 Attenuation switchable in section dB 10 Attenuation adjustable dB 10 Notches adjustable X 6 dB 10 Noise figur dB lt 6 Linearity dB 1 Output frequency range MHz 87 5 108 0 Output level max dBuV gt 100 Return loss MOF in output dB gt 10 Temperature operation oC 10 50 Weight standard module kg 0 45 Dimensions H x D x W mm 150 x 230 x 50 Remarks 6 individual filters 107 TDH AV modules TDH modulator modules convert an audio video signal to a TV channel in the VHF UHF band for distribution in a community cable system Full band high quality modulator Adjacent channel operation Multi standard Multi language menu Mono sound A2 stereo Nicam available Technical data TDH AV modulator TDH 725 TYPE AV master AV master VSB module VSB module Mono AZ stereo Nicam Part No B G 490766 490767 590767 D K
299. or perfect installations SO a D Complete GF wall bracket set Technical data on wall brackets Type GF 85 GF 110 170 GE 40 EIS Wo bracket set bracket set bracket set bracket set Part No 140033 140040 140038 140039 Diameter mm 30 50 30 50 30 50 30 50 Clearance from wall mm 15 15 15 15 Length mm 850 1100 1750 1250 1750 Height mm Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 Technical data on mast brackets Type Mast brac Mast brac Mast brac Mast brac Mast brac Mast brac Mast brac straight right left Universal straight right left Part No 132003 132004 132005 132102 132006 132007 132008 Diameter mm 38 38 38 42 50 50 50 Material Galv steel Galv steel Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 66 Mounting pipes Single straight pipe Single angle pipe long Double straight pipe Single angle pipe short Double angle pipe Technical data on mounting pipes Single straight Single angle Single angle Double straight Double angle pipe pipe short pipe long pipe pipe 140005 140010 140011 140009 140012 Mast diameter mm 30 50 30 50 30 50 30 50 30 50 Diameter on bracket mm 32 32 32 32 32 Material Galv steel Galv steel Galv steel Galv steel Galv steel Length mm 500 500 90
300. oster amplifiers IFB indoor amplifiers with F connectors Booster amplifier for MATV F connector Wide range with 2 outputs Seperate adjustable gain on VHF and UHF Click on wall mounting Technical data on IFB booster amplifiers A IFB booster amplifier housing IFB 402 IFB 403 IFB 404 IFB 405 339402 339403 339404 339405 Input 1 Channel Band UHF VHF UHF VHF UHF VHF UHF VHF Gain dB 6 16 0 10 6 16 6 16 7 17 15 25 15 25 Noise figure UHF dB lt 5 0 lt 5 0 lt 5 0 lt 5 0 lt 5 0 VHF dB lt 4 0 lt 4 0 lt 4 0 lt 4 0 lt 4 0 Max output voltage 60 dB IMA GEUN 2 x 107 2 x 107 2 x 107 2 x 105 Numbers of in output 1 2 1 2 1 2 1 2 Voltage V AC 230 230 230 230 Power consumption W 3 3 3 3 Connector F connector F connector F connector F connector Impedance Ohm 75 75 75 75 Operation temperature range C 0 50 0 50 0 50 0 50 Weight kg 0 400 0 400 0 400 0 400 Dimensions h x d x w mm 61x44x118 61x 44x118 61 x 44x 118 61x 44x 118 Remarks 2 separat 2 separat 1 2 separat UHF and VHF UHF and VHF attenuator UHF and VHF attenuator attenuator attenuator 164 Triax indoor booster amplifiers IIB indoor amplifiers with IEC connectors e Booster amplifier for MATV F connector Wide range with 2 outputs Seperate adjustable gain on VHF and UHF e o O e Click on wall mounting IIB amplifier housing Technical data on IIB booster amplifier
301. out In out In out In out In out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector Certification CE CE CE Ce Ce Impedance Ohm 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 190 Triax taps TLT series outdoor TLT 423 TLT 426 TLT 429 TLT 432 TLT 435 80251 80252 80253 80254 80255 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 1 Outputs pcs 4 4 4 4 4 Insertion loss 5 40 MHz dB lt 0 8 lt 0 8 lt 0 8 lt 0 8 lt 0 8 40 470 MHz dB lt 1 3 lt 1 3 lt 1 3 lt 1 3 lt 1 3 470 750 MHz dB lt 2 0 lt 2 0 lt 2 0 lt 2 0 lt 2 0 750 862 MHz dB lt 2 0 lt 2 0 lt 2 0 lt 2 0 lt 2 0 Tap loss output 5 40 MHz dB 23 0 41 2 26 0 41 2 29 0 41 2 32 0 1 2 35 0 41 2 40 470 MHz dB 23 0 1 2 26 0 41 2 29 0 41 2 32 0 1 2 35 0 41 2 470 750 MHz dB 23 0 1 5 26 0 41 5 29 0 41 5 32 0 1 5 35 0 1 5 750 862 MHz dB 23 0 1 5 26 0 41 5 29 0 41 5 32 0 1 5 35 0 1 5 Isolation out tap 5 40 MHz dB gt 27 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 40 470 MHz dB gt 27 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 470 750 MHz dB gt 27 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 750 862 MHz dB gt 27 0 gt 30 0 gt 30 0 gt 30 0 gt 30 0 Isolation tap tap
302. plifiers Diplex filter modules TYPE Part No Description MDA 3047 322250 Low loss high precision diplex filter for 5 30 MHz return path MDA 4254 322252 Low loss high precision diplex filter for 5 42 MHz return path MDA 5573 322254 Low loss high precision diplex filter for 5 55 MHz return path MDA 6080 322256 Low loss high precision diplex filter for 5 60 MHz return path MDA 6587 322258 Low loss high precision diplex filter for 5 65 MHz return path Splitter taps modules Part No TYPE Description MS 100 322270 MS 100 module out A B 0 no pass MS 101 322271 MS 101 module out A B No pass 0 MS 404 322273 MS 404 splitter module out A B 3 5 3 8 3 3 3 7 dB MS 207 322274 MS 206 tap module out A B 5 6 5 8 32 2 2 4 dB MS 110 322276 MS 110 tap module out A B 10 0 10 0 1 1 1 0 dB MS 114 322277 MS 114 tap module out A B 14 0 14 0 0 7 0 0 dB MS 118 322278 MS 118 tap module out A B 18 0 17 8 0 4 0 0 dB MA 6510 return path amplifier TYPE Part No MA 6510 322248 Frequency range 5 65 Gain 10 Packing size 1 Dynamic ingress blocker module TYPE Part No Description MDIB 100 322246 Dynamic ingress blocker module Link module Part No TYPE Description ML 01 322232 Link module interstage ML 02 322234 Link module return path HFA 60x amplifier Power
303. pper for RG 11 cable 209 100257 Aerial 8el ch 6 14 140008 50mm x 4 m Mast 62 153602 Cable stripper for RG 6 cable 209 100357 Aerial 8el ch 8 15 140120 50mm x 6 m Mast 62 153634 Cable support tool 209 er gt ann P SP u uue O 100407 Aerial 8el ch 9 15 140122 50 mm x 6 m Mast 63 100457 Aerial Bel ch 10 15 140135 Camping mast indoor 63 342101 5020 attenuators 196 100207 Aare Bel ar 5 14 153540 CC SP 01 cable assembly kit 212 336106 601 60 B 199 400014 Aerial Del a 3 a 153542 CC SP 02 cable assembly kit 212 336121 602 60 B 199 ee ZE 153544 CC SP 04 cable assembly kit 212 100012 Aerial 3el ch 2 4 8 336350 651 350 199 400013 Aerial 3el ch 2 4 foldable reflektor 8 133225 Centre mount 27 312250 7000 FXX 4 x UHF 52 346182 APS 007 EE EEE 197 301379 Ch 10 11 TDH Channel filter 110 312264 70XX FYY BIIl 21 40 52 324121 ARM EEE EE EE 120 301380 Ch 12 S 11 TDH Channel filter 110 312263 70XX FYY BIll 41 60 52 pai 301321 Ch 21 22 TDH Channel filter 110 324124 ARM 423 multiband amp 3in1out 120 311122 71234 B Combiner 56 301323 Ch 23 24 TDH Channel filter 110 324122 ARM 455 multiband amp 5in1out 120 311125 7132 G Combiner 56 301325 Ch 25 26 TDH Channel filter 110 324123 ARM 486 multiband amp 6in1out 120 315103 720 Bill 59 153070 Arrow T25 Stitcher 74 301327 Ch 27 28 TDH Channel filter 110 315114 721 UHF 59 301329 Ch 29 30 TDH Channel filter 110 aoa 324585 ASA 015 PSU 230VAC 15V 1 5ADC 119 TTF 315115 741 UHF 59 301331 C
304. r VHF dB gt 85 gt 85 gt 85 gt 85 UHF dB gt 75 gt 75 gt 75 gt 715 Connectors TV IEC male lIEC male lIEC male IEC male Radio IEC female lIEC female IEC female lIEC female Data F female F female F female F female DC through No No No No Standards CE EN 50083 4 EN 50083 4 EN 50083 4 EN 50083 4 Impedance Ohm 75 75 75 75 Weight kg 0 165 0 165 0 165 0 165 Dimensions mechanical mm O60 O60 O60 60 Remarks Please refer to page 232 for cover frame and terminators According to CENELEC B 5 40 MHz gt 18 dB 40 862 MHz min 18 dB 1 5 oct C 5 40 MHz gt 14 dB 40 862 MHz min 14 dB 1 5 oct D 5 862 MHz gt 10 dB 218 TOU multimedia outlet housing Triax TOU multimedia tv radio outlets Triax TOU loop through multimedia tv radio high quality outlets The Triax TOU series of outlets is made of di cast aluminium the coax IEC connectors fulfil the DIN 45325 and IEC 169 standards The outlets can be built into a 60 mm round wall box or surface mounted by means of a TOU frame Technical data on terminated multimedia outlets Data 5 1000 MHz TYPE TOU 4DT TOU 8DT TOU 10DT Part No incl cover and frame 302630 302631 302632 excl cover and frame 302680 302681 302682 Outputs TV Radio TV Radio TV Radio Data Data Data Frequency range TV MHz 125 862 125 862 125 862 Radio MHz 87 5 108 87 5 108 87 5 108 Data MHz 5 1000 5 1000 5 1000
305. r LNB power supply max A 1 3 1 3 1 3 1 3 Power link for amplifiers in the line Yes Yes Yes Yes Control LEDs Green for power Green for power Green for power Green for power Yellow for power link Yellow for power link Yellow for power link Yellow for power link Colourcoding of IF and TER inputs Yes Yes Yes Yes Temperature range oC 0 55 0 55 0 55 0 55 Dimensions H x D x W mm 125 x 55 x 355 125 x 55 x 355 215 x 55 x 355 215 x 55 x 355 131 Triax TMS 9xC multiswitches Fulfilling subscriber needs the most efficient way The TMS 9x series of our multiswitch systems offers unique subscriber benefits in terms of performance and individual freedom Advanced technology is used to provide these benefits but is applied in a logical modular way helping the professional installer save time TMS 9X12C Technical data Cascadable multiswitches with 8 polarities 1 terr input External power supply TMS 9x4C TMS 9x6C TMS 9x8C TMS 9x12C TMS 9x16C 300364 300366 300368 300372 300376 Number of inputs 8 SAT 1 TER 8SAT 1 TER 8SAT 1TER 8SAT 1 TER 8SAT 1 TER Number of outputs 8 SAT 1 TER 8SAT 1 TER 8SAT 1TER 8SAT 1TER 8SAT 1 TER Subscriber outputs 4 6 8 12 16 Connectors F con female female female female female Frequency range SAT MHz 950 2150 active 950 2150 active 950 2150 active 950 2150
306. r supply TYPE TNH 006 Power supply Part No 324900 Input voltage V AC 90 264 50 60 Hz Output voltage V DC 30 V DC 15 V DC 5 V DC 3 3 i rE Weight kg 5 0 TNH 006 power supply Dimensions per module H x D x B mm 231 x 148 x 70 EO A V data cable for programming TNH via PC Part No 324904 115 Triax TCM 08 modulator headend TCM 08 8 modulator unit The modular design makes it easy to adapt the system to the required number of programmes t Technical data TCM 08 modulator cabinets ea 1 TYPE TCM 08 TCM 08A basic unit basicuit gt Part No 300110 300111 a TCM 08 Output frequency range MHz 47 862 47 862 Attenuation dB 10 Output level max IMD 60 dB dBuV 80 8 ch 105 8 ch Return loss output dB gt 14 47 MHz min 10 gt 14 47 MHz min 10 Output impedance Ohm 75 75 Input voltage V ac 190 260 190 260 Power consumption 8 modulator W 17 20 RF output OUT 1 x F type 1 x F type Temperatur operation C 0 50 0 50 Weight kg 4 4 4 6 Dimensions H x D x W mm 180 x 440 x 130 180 x 440 x 130 Modules for TCM 08 Technical data CM 02 modulator modules for TCM 08 TYPE CM 02V CM 02U Nicam VHF mod UHF mod encoder Part No 490898 490899 490884 TV system B D I L AU NZ G K I L
307. range MHz 4 65 Through loss dB bd General Power supply V AC 230 10 230 10 V DC 12 24 Power consumption mA 250 v 15V Connectors F female F female Certification CE CE Impedance Ohm 75 75 Operation temperature range GE 0 50 0 50 Weight kg 1 4 1 4 Dimensions H x D x W mm 100 x 62 x 185 100 x 68 x 187 128 TMS series Triax TMS multiswitches TMS 17C and 17T series TMS 9C and 9P series TMS 5 and 5P series TMS 2C series TMS taps splitters TMS amplifiers TMS power supplies Districom 4000 Accessories a TMS 17x466 Part no 301516 Err hs TERR Ze ZA lt j vical spec nz 5862 C Technica 7 ange forward MHZ Ed GO 45 EZ Frequency fa ath MHz Apala F i e retun D 7aBri 208 d Erequency fang k 9748 adp l 208 SEA i Ze loss TUN gu d outs insertion iner output AOB 47 ZG ingertion On Subscriber deri Ht Za m Output level Gide err j z b Pi area is 2 er g 4 1 e UI A T oe A im wa E AT Ee I d 130 131 132 133 134 135 136 137 138 139 140 141 142 147 148 CE 129 Triax TMS 17xC multiswitches Fulfilling subscriber needs the most efficient way Each of our multiswitch systems offers unique subscriber benefits in terms of per formance and individual freedom Advanced technology is used to provide these benefits but is applied in a logical modular way helping the professional insta
308. rating voltage Vertical VDC 10 5 14 5 10 5 14 5 10 5 21 10 5 14 5 Horizontal VDC 15 5 21 15 5 21 10 5 21 15 5 21 Switching Low band Hz D 0 0 High band KHz 22 4 22 4 22 4 Position none none none DiSEqC 2 0 Operating temperature range C 40 60 40 60 40 60 40 60 Dimensions Diameter mm 40 40 40 40 Width x Heigth x Depth mm 59 x 137 x 97 59 x 137 x 97 59 x 137 x 97 59 x 137 x 97 Max depth incl feedhorn mm 145 145 135 145 Weight kg 0 355 0 365 0 365 0 375 Packing size pcs 30 30 30 30 90 Technical data Triax LNB units the best choice TSI 001 TTW 001 TQD 001 TQT 001 Single universal Twin universal Quad universal Quattro universal 300404 300407 300415 300411 Colour light grey Ral 7035 Ral 7035 Ral 7035 Ral 7035 RF input Input frequency range Low band GHz 10 7 11 7 10 7 11 7 10 7 11 7 10 7 11 7 High band GHz 11 7 12 75 11 7 12 75 11 7 12 75 11 7 12 75 Feedhorn GHz F D 0 615 11 7 F D 0 615 11 7 F D 0 615 11 7 F D 0 615 11 7 IF output Output frequency range Low band MHz 950 1950 950 1950 950 1950 950 1950 High band MHz 1100 2150 1100 2150 1100 2150 1100 2150 Output connector type 75Q female 75Q female 75Q female 75Q female Output VSWR room temp 2 0 1 typ 2 0 1 max 2 0 1 max 2 1 1 max Local oscillator Frequency Low band GHz 9 75 9 75 9 75 9 75 H
309. re Fits 5 mm wire 1 8 wire 3 16 wire 1 8 wire 3 16 wire d 69 Chimney bracket sets Technical data on accessories cS E We Single chimney bracket set w mast bad TO Double chimney bracket set Single wireset a d ci Single chimney bracket set 2 parts chimney bracket set Technical data on accessories Type Single wireset Single chimney Double chimney 2 parts chimney 2m mast with spare parts bracket set bracket set bracket set chimney bracket Part No 130001 130002 130004 130000 130006 Mast diameter mm 38 50 38 50 38 50 38 Material Galv steel Galv steel Galv steel Galv steel Galv steel Weight kg Packing QTY pcs 1 1 1 1 1 Sets consist of 1 x Wire 5 mm 1 Chimney bracket 1 Chimney bracket 2 Chimney bracket 1x2 m mast with lenght 3 6 m 1 x Wire 5 mm 2 x Wire 5 mm 2 x Wire 5 mm chimney bracket 4 x Corner brackets lenght 3 6 m lenght 3 6 m lenght 3 6 m 1 x Wire 5 mm 2 x J bolts 3 x Corner brackets 6 x Corner brackets 6 x Corner brackets lenght 3 6 m 2 x Wirelock 2 x J bolts 4 x J bolts 4 x J bolts 3 x Corner brackets 2 x Wirelock 4 x Wirelock 4 x Wirelock 2 x J bolts 2 x Clamps with 2 x Clamps with 2 x Clamps with 2 x Wirelock bolts bolts bolts Technical data on accessories Type Chimney Steel band bracket Part No 140032 140034 Mast diameter mm 38
310. rs without return path GE e compact indoor distribution amplifier in a modern white shielded plastic N housing for indoor use only AN e Recommended for low channel density MATV E ed a IFA amplifier housing Technical data on IFA distribution amplifiers TYPE IFA 218 IFA 219 IFA 220 Part No 339218 339219 339220 Forward path Frequency range MHz 47 862 47 862 47 862 Gain 47 862 MHz dB 11 0 20 0 17 Noise figure dB lt 5 5 lt 6 0 lt 6 0 Linearity dB 1 0 41 5 dido Slope dB Equalizer dB 0 18 0 18 Outputs pcs 1 1 2 Output level 60 dB 3 order DIN 45004B GEUN 114 0 112 0 108 0 60 dB 2 order DIN 45004A1 GEUN 104 0 104 0 100 0 60 dB CTB 1 dBuV 96 0 96 0 92 0 60 dB CSO 1 dBuV 96 0 96 0 92 0 Return loss 47 MHz 1 5 dB octave dB gt 14 gt 14 gt 14 Return path Frequency range MHz Through loss dB General Power supply VDC 230 10 230 10 230 10 Power consumption W 3 0 3 0 3 0 Shielding efficiency VHF dB 15 15 15 Shielding efficiency UHF dB 65 65 65 Connectors F connector F connector F connector Certification CE CE CE Impedance Ohm 75 75 75 Operation temperature range C 0 50 0 50 0 50 Weight kg 0 400 0 400 0 400 Dimensions h x d x w mm 61x44x118 61x44x118 61x44x118 1 DIN EN 50083 Part 3 CTBA Composite triple beat ratio 60 dB IMR CENELEC raster 42 channels 162 Triax indoor distribution amplif
311. s IIB 434 IIB 435 IIB 445 339434 339435 339445 Input 1 Band UHF VHF UHF VHF UHF VHF Channel 2 12 21 69 2 12 21 69 2 12 21 69 Gain dB 6 16 10 20 15 25 15 25 Noise figure UHF dB lt 5 0 lt 5 0 lt 5 0 VHF dB lt 5 0 lt 5 0 lt 5 0 Max output voltage 60 dB IMA dBuvV 2x 105 108 2x 105 Numbers of in output 1 2 1 1 1 2 Voltage V AC 230 230 230 Power consumption W 3 3 3 Connector type IEC IEC IEC Impedance Ohm 75 75 75 Operation temperature range C 0 50 0 50 0 50 Weight kg 0 400 0 400 0 400 Dimensions h x d x w mm 61x44x118 61 x 44x 118 61x 44x 118 Remarks IEC connectors IEC connectors IEC connectors 1 female 2 male 1 female 2 male 1 female 2 male 1 Attenuator 1 Attenuator 1 Attenuator 165 Triax indoor amplifiers Indoor amplifiers with saddle and clamp or IEC connectors TRIAX TA distribution amplifiers are with saddle and clamp cable mounting designed for indoor mounting and have built in power supply They are used primarily when signals are too weak for distribution to several outlets Distribution amplifiers are available with 1 or 2 outputs Technical data on indoor amplifiers TA 415 22 Type TA 415 22 TA 415 22R Type 02 2TV 2TV plus Part No 330550 330551 345100 345110 345111 Input 1 Band UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF Channel 1 in ch 30 40 Frequency MHz 47 862 47 862 47 862 47 862 47 862
312. s with 16 polarities 1 terr input External power TMS 17x6T TMS 17x8T TMS 17x12T TMS 17x16T 301606 301608 301612 301616 Number of inputs 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER Number of outputs 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER 16 SAT 1 TER Subscriber outputs 6 8 12 16 Connectors F con female female female female Frequency range SAT MHz 950 2150 active 950 2150 active 950 2150 active 950 2150 active Frequency range TER MHz 5 862 passive 5 862 passive 5 862 passive 5 862 passive Gain SAT dB 2 0 2 D Gain TER dB 21 22 24 24 Noise figur SAT dB Isolation LNB to LNB dB 35 35 35 35 Isolation TER to SAT dB 20 20 20 20 Isolation SAT to TER dB 30 30 30 30 Isolation cross polarisation H V dB 28 28 28 28 Isolation out out TER dB 20 20 20 20 Isolation out out SAT dB 30 30 30 30 Return loss SAT inputs dB 12 12 12 12 Return loss SAT outputs dB 12 12 12 12 Return loss TER inputs dB 8 8 8 8 Return loss TER outputs dB 8 8 8 8 Output level SAT IMD3 35 dB GEUN 100 100 100 100 Impedance input output Ohm 75 75 75 75 Switching VDC 13 V 18 V 13 V 22 kHz 13 V 18 V 13 V 22 kHz 18 V 22 kHz DiSEqC 2 0 18 V 22 kHz DiSEqC 2 0 Toneburst Toneburst Supply voltage VDC 15 0 5 15 0 5 15 0 5 15 0 5 Power supply External power External power External power External power adaptor adaptor adaptor adapto
313. schable Switschable on all inputs onallinputs onallinputs onallinouts onallinputs on all inputs Connector S amp C S amp C S amp C S amp C S amp C S amp C Weight kg 0 5 0 5 0 5 0 5 0 5 0 5 Dimensions Height mm 122 122 122 122 122 122 Depth mm 55 55 55 55 55 55 Width mm 168 168 168 168 168 168 Remarks Multichannel Multichannel Multichannel Multichannel Multichannel Multichannel 44 OISIN E CH 33 43 50 CH 23 60 Rest UHF BI BII Je ye C AMPLIFIER VERSION A334353 2360 A1 D DO V DO O d AN GS e e Triax TA multichannel amplifier series TRIAX s TA multichannel amplifier Besides the standard types multichannel amplifiers are available on request in versions with special XX and YY channels where XX is the first UHF channel and YY the second UHF channel within the channel range 21 60 and in a type with a Z channel within VHF BIII in the channel range 5 12 326858 Type AXX Z A13 326859 Type AXXYY Z A1 gt Note There will always be 2 locked channels on each side of the selected channels A334350 AXXYY AXXYY A5053 7 A1 A45 3153 A45 XX 2360 A1 00 A1 Z A1 326850 326840 326859 326861 326878 326880 Input 1 Channel Band 33 43 50 XX YY XX YY
314. sions Diameter mm 40 40 40 40 Width x Heigth x Depth mm 599 x 59 x 112 59 x 137 x 97 59 x 137 x 97 59 x 137 x 97 Max depth incl feedhorn mm 112 145 145 135 Weight kg 0 130 0 025 0 355 0 365 0 365 Packing size pcs 50 30 30 30 91 Universal LNB units Alps supplies a full range of quality LNBs Availbale as single dual and quad for 1 2 or 4 set top boxes Also available in quattro version for community aerial systems Full Ku band coverage for both analogue and digital reception Low noise figures 0 6 dB High cross polar isolation typically gt 25 dB Technical data ALPS ALPS Twin ALPS Quad ALPS Quattro Single universal universal V H universal universal 300464 300462 300467 300468 Colour light grey Ral 7035 Ral 7035 Ral 7035 Ral 7035 Input frequency range Low band GHz 10 7 11 7 10 7 11 7 10 7 11 7 10 7 11 7 High band GHz 11 7 12 75 11 7 12 75 11 7 12 75 11 7 12 75 Feedhorn GHz Output frequency range Low band MHz 950 1950 950 1950 950 1950 950 1950 High band MHz 1100 2150 1100 2150 1100 2150 1100 2150 Output connector type 75Q female 75Q female 75Q female 75Q female Output VSWR room temp Frequency Low band GHz 9 75 9 75 9 75 9 75 High band GHz 10 6 10 6 10 6 10 6 Frequency stability MHz 3 max 3 max 3 max 3 max Phase noise room temperature DBc Hz 55 1 kHz max 55 1 kHz max 55 1 kHz max 55 1 kHz max DBc Hz
315. stine the cable for use of SAT IF especially and SMATV applications without any return path services as well Technical data on KOKA 6 and 6 CCS indoor cable KOKA 6 KOKA 6 CCS Double shielded Double shielded White Grey White Grey PVC PVC PVC Part No Coil 100 m 150120 Reel 100 m 150121 150131 Reel 250 m 150122 Drum 500 m Drum 1000 feet 305 m 150144 Center conductor mm 1 02 1 02 Center conductor material Cu blank Cu clad steel Isolation mm 4 8 4 8 Dielectric PE foamed PE foamed Screen AL P AL AL P AL um 9 12 9 9 12 9 Braid material 16x4x0 12 bai i 16x4x0 12 bal construction mm AL 5 4 AL 5 4 coverage gt 43 gt 40 Screening attenuation dB 75 85 75 85 Anti migration foil um 12 12 Outer sheath PVC PVC Minimum bending radius mm 35 70 35 70 Diameter mm 6 8 6 8 Application Indoor Indoor ELECTRICAL DATA Impedance Ohm 75 75 Capacitance pF m 52 52 Velocity ratio 84 84 Center conductor dc resistance Ohm km 18 Outer conductor dc resistance Ohm km 21 Attenuation at 20 C 5 MHz dB 100m 15 1 5 50 MHz dB 100m 4 6 4 6 100 MHz dB 100m 200 MHz dB 100m 9 0 9 0 400 MHz dB 100m 800 MHz dB 100m 18 8 18 8 862 MHz dB 100m 1000 MHz dB 100m 21 1 21 1 1600 MHz dB 100m 2150 MHz dB 100m 30 8 30 8 2400 MHz dB 100m 32 8 32 8 Structural Return Loss SRL
316. t 0 8 lt 0 8 470 750 MHz dB lt 3 0 lt 2 4 lt 1 2 lt 1 0 lt 1 0 lt 1 0 lt 1 0 750 860 MHz dB lt 3 2 lt 2 5 lt 1 3 lt 1 1 lt 1 1 lt 1 1 lt 1 1 860 1000 MHz dB lt 3 4 lt 2 lt 1 5 lt 1 2 lt 1 2 lt 1 2 lt 1 2 Tap loss in tap 5 40 MHz dB 6 0 1 5 8 0 1 0 12 0 1 0 16 0 1 0 20 0 1 0 24 0 1 0 30 0 1 0 40 470 MHz dB 6 0 1 5 8 0 1 0 12 0 1 0 16 0 1 0 20 0 1 0 24 0 1 0 30 0 1 0 470 750 MHz dB 6 0 1 5 8 0 1 0 12 0 1 0 16 0 1 0 20 0 1 0 24 0 1 0 30 0 1 0 750 860 MHz dB 6 0 1 5 8 0 1 2 12 0 1 2 16 0 1 2 20 0 1 2 24 0 1 2 30 0 4 1 2 860 1000 MHz dB 6 0 2 0 8 0 1 5 12 0 1 5 16 0 1 5 20 0 1 5 24 0 1 5 30 0 1 5 Isolation out tap 5 40 MHz dB gt 25 0 gt 24 0 gt 24 0 gt 28 0 gt 32 0 gt 36 0 gt 36 0 40 470 MHz dB gt 28 0 gt 28 0 gt 28 0 gt 30 0 gt 32 0 gt 34 0 gt 34 0 470 750 MHz dB gt 25 0 gt 25 0 gt 25 0 gt 28 0 gt 30 0 gt 33 0 gt 33 0 750 860 MHz dB gt 24 0 gt 25 0 gt 26 0 gt 28 0 gt 30 0 gt 32 0 gt 32 0 860 1000 MHz dB gt 23 0 gt 24 0 gt 25 0 gt 27 0 gt 29 0 gt 31 0 gt 31 0 Return loss in out 5 40 MHz dB gt 21 0 gt 19 0 gt 21 0 gt 21 0 gt 22 0 gt 22 0 gt 22 0 40 470 MHz dB gt 20 0 gt 20 0 gt 20 0 gt 20 0 gt 22 0 gt 22 0 gt 22 0 470 750 MHz dB gt 19 0 gt 20 0 gt 20 0 gt 2
317. t 25 0 gt 30 0 gt 30 0 gt 27 0 gt 30 0 gt 30 0 40 470 MHz dB gt 25 0 gt 30 0 gt 30 0 gt 25 0 gt 30 0 gt 30 0 470 860 MHz dB gt 25 0 gt 28 0 gt 28 0 gt 28 0 gt 25 0 gt 25 0 Return loss in out 5 40 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 40 470 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 470 860 MHz dB gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 gt 10 0 Return loss tap 5 40 MHz dB gt 23 0 gt 23 0 gt 23 0 gt 24 0 gt 24 0 gt 24 0 40 470 MHz dB gt 24 0 gt 24 0 gt 24 0 gt 25 0 gt 25 0 gt 25 0 470 860 MHz dB gt 20 0 gt 21 0 gt 21 0 gt 22 0 gt 22 0 gt 22 0 Shielding efficiency VHF UHF dB gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 gt 110 0 Power pass No No No No No No Connectors F connector F connector F connector F connector F connector F connector Certification CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 Weight kg 0 134 0 134 0 134 0 137 0 137 0 137 Dimensions h x d x w mm 60x16x11 7 60x16x117 60x16x117 60x16x117 60x16x117 60x16x117 179 Triax multitaps HTT series 5 1000 MHz CLASS HTM 4 12T HTM 6 12T HTM 8 12T TTM 12 347413 347617 343912 Frequency range MHz 5 862 5 862 5 862 5 862 5 862 Outputs pcs 4 6 8 12 16 Insertion loss in out 5 40 MHz dB 4 0 1 5 6 0 1 5 8 0 1 5 40 470 MHz dB 4
318. t 3 0 lt 3 0 SAT SAT II dB lt 3 0 lt 3 0 lt 3 0 lt 1 5 Return dB Connectors TV lIEC male lEC male lIEC male lIEC male Radio lIEC female lIEC female lIEC female lEC female SAT F female F female Return F female DC through in SAT V mA Yes TV Yes SAT Yes SAT Yes SAT 1 SAT 2 Fits 15 mm patress Yes Yes Yes Yes Impedance Ohm 75 75 75 75 Weight kg Dimensions w x h x d mm 50 x 50 50 x 50 50 x 50 50 x 50 Remarks 231 Accessories for TOU outlets Covers for TOU standard outlets 2 holes TYPE Cover white Cover off white Part No 303680 303681 Cover UK white 303690 Size mm 76x76 86 x 86 Packing size 10 pcs 10 pcs zadi eio design TYPE Cover white Cover off white Part No 303685 303686 Size mm 76 x 76 76x76 Packing size 10 pcs 10 pcs Na Covers for TOU satellite outlets 3 holes Cover UK white TYPE Cover white Cover off white Part No 303682 303683 Size mm 76 x 76 76x76 Packing size 10 pcs 10 pcs 303692 gt UK design Frame white Frame off white 303698 303699 Size mm 76x76 Packing size 10 pcs RF terminator R75 75Q R1000 75Q terminator terminator Part No 5 pcs 342503 342504 Remarks TD outlets TOU outlets ts GY yp 232 Covers for TD outlets TYPE 0 holes cover 2 holes cover 3 holes cover 50 x 50 mm 50 x 77 mm GUK I TI Part No white 485968 3020
319. t 54 gt 54 gt 54 Differential phase deg lt 8 lt 8 lt 8 lt 8 Picture carrier stability kHz lt 70 lt 70 lt 70 lt 70 Spurious signals ref pict carrier C N dB gt 60 gt 60 gt 60 gt 60 Sound mode Mono A2 stereo Nicam Mono A2 stereo Nicam Audio distortion 1 kHz lt 1 lt 1 lt 1 lt 1 Audio S N ratio dB gt 50 gt 50 gt 50 gt 50 Sound sub carrier stability kHz lt 5 lt 5 lt 5 lt 5 LNB control 13 18 volt 0 22 kHz mA 200 200 200 200 Conditional access EN 50221 50221 FTA FTA Teletext type Reinserted in VBI Reinserted in VBI Reinserted in VBI Reinserted in VBI Demultiplexer data rate Mbps lt 65 lt 65 lt 65 lt 65 Video data rate Mbps lt 15 lt 15 lt 15 lt 15 Viterbi rates Mpps 1 30 SCPC MCPC 1 30 SCPC MCPC 1 30 SCPC MCPC 1 30 SCPC MCPC FFT mode Mpps 2K 8K 2K 8K 2K 8K 2K 8K Constellations QPSK 16QAM 64QAM QPSK 16QAM 64QAM Guard interval 1 4 1 8 1 16 1 32 1 4 1 8 1 16 1 32 Viterbi decoder 1 2 2 3 3 4 5 6 7 8 1 2 2 3 3 4 5 6 7 8 Reed Solomon decoder 204 188 t 8 204 188 t 8 Impedance Ohm 75 75 75 75 Operation temperature range oC 10 50 10 50 10 50 10 50 Weight standard module kg 0 45 0 45 0 45 0 45 Dimensions H x D x W mm 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 150 x 230 x 50 Remarks Digital measuring DCP Mounted in stand alone cabinet 102 Slave modules for DVB S or DVB T master modules
320. t 3 Channel Band VHF BI FM Gain dB 10 20 2 12 Noise figure INI IN2 UHF dB 3 0 3 0 2 5 5 0 14 0 4 0 4 0 VHF dB 3 0 5 0 3 0 3 0 4 0 4 0 Max output voltage 60 dB IMA GEUN 103 103 105 110 105 103 Numbers of in output 1 1 2 1 2 1 3 1 3 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 30 45 45 45 45 45 DC throughpower UHF UHF Connector F con F con F con F con F con F con Weight kg 0 230 0 230 0 230 0 230 0 230 0 230 Dimensions Height mm 108 108 108 108 108 108 Depth mm 50 50 50 50 50 50 Width mm 120 120 120 120 120 120 Remarks 34 Triax MFA mast amplifier series Technical data on MFA mast amplifiers with F connectors MFA 311 MFA 312 MFA 313 MFA 314 MFA 320 MFA 321 340311 340312 340313 340314 340320 340321 Input 1 Channel Band UHF UHF BI Ill UHF 1 UHF UHF TV Gain dB 12 22 25 35 15 25 20 30 22 33 25 35 22 32 Input 2 Channel Band VHF UHF 2 BI BIll Bill FM Gain dB 2 20 30 15 25 15 25 10 20 Input 3 Channel Band BI BIII BI FM Gain dB 15 25 15 25 Noise figure IN1 IN2 UHF dB 3 0 4 5 8 8 8 5 7 0 7 0 4 5 4 0 3 5 VHF dB 4 0 4 0 4 0 5 0 Max output voltage 60 dB IMA dBuyuV 103 103 103 103 103 103 Numbers of in output 2 1 1 1 3 1 2 1 3 1 2 1 Voltage VDC 12 24 12 24 12 24 12 24 12 24 12 24 Power mA 30 30 30 30 25 25 DC throughpower Connector F con F con F con F con F con F con Weight kg 0 230 0 230 0 230 0 230 0 230 0 230 Dimensions Height mm 108 108 108 1
321. t 3 Gain dB 27 42 25 40 27 47 16 36 Input 3 Noise figure dB 5 0 8 0 5 0 7 0 Input 4 Frequency range MHz 470 862 470 862 470 862 Input 4 Gain dB 25 40 20 40 24 44 Input 4 Noise figure dB 8 0 9 0 5 0 Input 5 Frequency range MHz 470 862 470 862 Input 5 Gain dB 20 40 24 44 Input 5 Noise figure dB 9 0 9 0 Input 6 Frequency range MHz 470 862 Input 6 Gain dB 27 47 Input 6 Noise figure dB 9 0 Output level 3 order VHF dBuV 117 0 117 0 117 0 121 0 60 dB IMD UHF GEUN 117 0 117 0 117 0 121 0 Connectors F F F F Impedance Ohm 75 75 75 75 Power consumption W T T 7 5 11 3 Remote supply V mA 12 100 12 100 12 100 12 60 Operation voltage V AC 185 265 185 265 185 265 185 265 Operation temperature range oc 0 50 0 50 0 50 0 50 Weight kg 1 250 1 250 1 250 1 250 Dimensions H x D x W mm 85 x 50 x 188 122 x 70 x 210 122 x 70 x 210 122 x 70 x 210 120 Triax multiband amplifiers IFM indoor multiband amplifier with F connectors e Attractive housing design Built in power supply e F connectors l e Separate adjustable gain on VHF and UHF e New click on wall mounting IFM amplifier housing Technical data on IFM multiband amplifiers Type IFM 102 IFM 103 IFM 104 Part No 339102 339103 339104 Input 1 Band UHF UHF UHF Channel 21 69 21 69 21 69 Gain dB 20 30 12 22 25 35 Input 2 Band VHF BIII BIII Channel 2 12 5 12 5 12 G
322. t Mast bracket Mast bracket 038 60 038 60 038 60 Plastic base Plastic base Plastic base Centre mount Part No 133225 Railing mount Part No 133221 27 Triax UFO aerial VHF UHF digital UFO Mobile digital Available with bracketry which can sustain the heavy wind loads to which the antenna is exposed during travel Can be mounted on mast or directly on the caravan with a small discreet bracket UFO Mobile digital Technical data UFO Mobile UFO Mobile UFO Mobile UFO Mobile Digital Digital Digital Digital 109696 109697 109698 109699 Frequency range FM MHz VHF MHz UHF MHz 470 862 470 862 470 862 470 862 Channels 21 69 21 69 21 69 21 69 Elements pcs 1 1 1 1 Opening angle _ ver hor deg 90 360 90 ver 860 hor 90 ver 360 hor 90 ver 360 hor Windload N 5 5 5 5 5 5 5 5 Gain dB 16 16 16 16 Noise figure dB 2 0 2 5 2 0 2 5 Max output voltage dBuvV 108 108 100 100 Supply voltage V 5 5 12 12 Power consumption mA 20 20 20 20 Dimensions length mm 325 325 325 325 width mm 255 255 255 255 height mm 65 65 65 65 Connector F connectors F connectors F connectors F connectors Power supply IFP 529 battery IFP 529 battery Packing size 1 1 1 1 Bracketry Mast bracket Centre mount Mast bracket Centre mount 025 38 025 38 Plastic base Universal mount Mast bracket Part No 133220 Part No 133222 25 38 Part No 1383224 38 60 Part No 133223 28
323. t Yes Yes Yes Yes Operation voltage V AC 190 260 190 260 190 260 from SA cabinet Power consumption W 120 max 110 max 25 max 8 Connector in out F female F female F female F female Operation temperature range SE 10 50 10 50 10 50 10 50 Weight kg 5 8 5 8 1 8 2 2 Dimensions H x D x W mm 223 x 160 x 440 223 x 160 x 440 198 x 220 x 76 198 x 141 x 44 Remarks bu aS z AD eg dd LINK d AA erta As yE LINK ii i ENS E TDH 700 E TDH 701 SS 5 SA controller sub unit p e TDH 791 LINK r SA cabinet LINK d RF out for 1 00 distribution net TDH digital satellite modules QPSK PAL TDH DVB S modules convert a coded or uncoded digital signal from a satellite to a modulated PAL SECAM signal for distribution in a community cable system Full band high quality modulator Conditional access via Cl or Free To Air Advanced watchdog function Fully DVB S compatible Multi language menu MPEG transport stream available for slave modules Mono sound A2 stereo Nicam available TDH FTA Technical data TDH DVB S master modules VSB VHF UHF DVB S master DVB S master DVB S master DVB S master with Cl with Cl Free to air Free to air Mono A2 stereo Nicam Mono A2 stereo Nicam Part No B G 490742 490743 590743 490746 490747 590747 D K 490702 490703 490722 490723 Norm L 490702 590703
324. t connection Controlling accessories for TDH headend N port for Internet B E GSM connection GSM modem for mobile phone Telephone modem Telephone modem for access 300766 Packing QTY pcs 1 300765 1 300764 1 What you can do and TDH manager e Type in the IP address e Select one of the virtual ports e Start controlling the TDH Get access via Internet e Install software for NBOX Get access via GSM e Install software for TDH manager e Dial up via built in modem or external standard telephone modem e Insert SIM data card in the GSM modem e Connect the GSM modem to TDH 700 modem port Get access via phone modem e Install software for TDH manager e Type in the telephone number e Dial up via built in modem or external standard telephone modem e Connect the standard telephone modem to TDH 700 modem port Remarks see page 111 for connection cable Power supply included Power supply not included see page 111 for connection cable Power supply included see page 111 for connection cable access anywhere anytime 109 Triax TDH channel filters Channel filter option For all TDH modules with a modulator it is possible to improve the C N in networks with high number of TV channels This is done by means of adding a channel filter on each module Technical data on TDH channel filters Channel filter
325. t grey Ral 7035 Ral 7035 Ral 7035 RF input Input frequency range Low band GHz 10 7 11 7 10 7 11 7 10 7 11 7 High band GHz 11 7 12 75 11 7 12 75 11 7 12 75 Feedhorn GHz F D 0 615 11 7 F D 0 615 11 7 F D 0 615 11 7 IF output Output frequency range Low band MHz 950 1950 950 1950 950 1950 High band MHz 1100 2150 1100 2150 1100 2150 Output connector type 75Q female 75Q female 75Q female Output VSWR room temp 2 5 1 typ 2 5 1 typ 2 5 1 typ Local oscillator Frequency Low band GHz 9 75 9 75 9 75 High band GHz 10 6 10 6 10 6 Frequency stability MHz 2 5 1 40 60 C 2 5 1 40 60 C 2 5 1 40 60 C Phase noise room temperature DBc Hz 50 1 kHz max 50 1 kHz max 50 1 kHz max DBc Hz 80 10 kHz max 80 10 kHz max 80 10 kHz max DBc Hz 100 100 kHz max 100 100 kHz max 100 100 kHz max Conversion performance room temp Conversion gain Typ dB 60 56 56 Max dB 65 62 62 Gain variation over operating band dB 5 p p typ 5 p p typ 5 p p typ Gain flatness across 26 MHz segm dB 0 5 typ 0 5 typ 0 5 typ Output power 1 dB gain comp dBm 5 typ 5 typ 5 typ Spurious level dBm 65 max 65 max 65 max Noise figure typ dB 0 3 0 3 0 3 max dB 0 6 0 6 0 6 Image rejection dB 45 min 45 min 45 min Cross polarization isolation dB 25 Typ 20 min 25
326. t to protect from elements Neoprene sealed and nickel plated brass for all 5 8 port entry and taps F f port Provides uninterrupted power and RF service when the faceplate is removed Technical data TLT series of 5 1000 MHz outdoor 8 taps TLT 811 TLT 814 TLT 817 TLT 820 80242 80239 80240 80241 Frequency range MHz 5 1000 5 1000 5 1000 5 1000 Inputs pcs 1 1 1 1 Outputs pcs 8 8 8 8 Insertion loss 5 40 MHz dB lt 3 4 lt 1 8 lt 1 2 40 470 MHz dB lt 3 4 lt 1 8 lt 12 470 750 MHz dB lt 4 5 lt 2 5 lt 2 5 750 862 MHz dB lt 45 lt 30 lt 2 5 Tap loss output 5 40 MHz dB 11 0 1 0 14 0 41 2 17 0 41 2 20 0 1 2 40 470 MHz dB 11 0 1 0 14 0 41 2 17 0 41 2 20 0 1 2 470 750 MHz dB 11 0 1 0 14 0 41 5 17 0 41 5 20 0 1 5 750 862 MHz dB 11 0 1 0 14 0 41 5 14 0 41 5 20 0 1 5 Isolation out tap 5 40 MHz dB gt 23 0 gt 25 0 gt 27 0 40 470 MHz dB gt 25 0 gt 25 0 gt 27 0 470 750 MHz dB gt 25 0 gt 25 0 gt 27 0 750 862 MHz dB gt 25 0 gt 25 0 gt 27 0 Isolation tap tap 5 40 MHz dB gt 20 0 gt 25 0 gt 25 0 gt 28 0 40 470 MHz dB gt 20 0 gt 25 0 gt 25 0 gt 28 0 470 750 MHz dB gt 20 0 gt 25 0 gt 25 0 gt 28 0 750 862 MHz dB gt 20 0 gt 25 0 gt 25 0 gt 28 0 Return loss out 5 40 MHz dB gt 16 0 gt 18 0 gt 18 0 gt 18 0 40 470 MHz dB gt 16 0 gt 20 0 gt 20 0 gt 20 0
327. tic housing for indoor mounting The splitters are with one broadband input and one output for DAB and one for TV FM The products are shielded and supplied with F connectors DC Through power to TV FM output The TFS 715 are normal indoor TV FM splitters to be mounted on a wall Technical data on Triax splitters TS 315 2 TFS 220 TFS 221 TFS 715 2 TFS 715 3 TFS 715 4 DC DAB TV FM DAB TV FM 332323 334220 334221 334202 334203 334204 Input 1 VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Channel Band 2 69 FM 2 69 FM 2 69 FM 2 69 FM 2 69 FM 2 69 FM Frequency range MHz 47 862 47 862 47 862 47 862 47 862 47 862 Splitter type Inductive Through loss VHF dB 4 0 DAB 1 5 DAB 1 5 4 0 6 0 8 0 UHF dB 4 0 TV FM 1 5 TV FM 1 5 4 0 6 0 8 0 Isolation dB 18 18 18 18 TV FM dB gt 20 gt 20 DAB dB gt 10 gt 10 Number of outputs pcs 2 2 3 4 TV FM 1 1 DAB 1 1 DC throughpower TV FM TV FM Output 1 Switchable DC DC DC Output 2 Switchable DC DC DC Output 3 DC DC Output 4 DC Connector S amp C F con F con F con F con F con Weight kg 0 150 0 150 Dimensions Height mm 15 15 Depth mm 36 36 Width mm 15 15 Remarks DAB ch DAB ch DC pass can DC pass can DC pass can 11 13 12 13 be removed by be removed by be removed by 216 240 MHz 223 251 MHz cutting PCB cutting PCB cutting PCB 194 Technical data on Triax splitters Triax splitters E 4010 203 B 309 407 102 FF
328. tion tribunal bring an action against him which deals with claims made against the seller for damages assertedly caused by the product 15 FORCE MAJEURE The seller s obligations are suspended and can be dropped when missing fulfilment is owing to conditions beyond the seller s control 16 CONSUMERS PURCHASES IN DENMARK For consumers purchases in Denmark the stipulations laid down in the Sale of Goods Act take precedence over these sales and delivery terms 17 VENUE AND LAW Any dispute arising out of the contract shall be settled before a Danish court The venue is S og Handelsretten in Copenhagen However the seller is entitled to demand arbitration according to the general rules of the Danish court The Court of Arbitration is set up in Copenhagen Settlement through arbitration does not exclude the possibility of an injunction or that other preliminary remedies can be carried through at the relevant revenue The information contained in this catalogue was to the best of the knowledge of Triax correct at the time of publication Triax reserves the right without prior notice to discontinue products or to make design changes as part of its continuous programme of product improvement Triax will not accept responsability for damage injury loss or expense resulting from any error or omissions Simply Qp more simply 259 Offices Triax Hirschmann Austria Empfangstechnik
329. tor F connector Certification CE CE CE Ce CE Impedance Ohm 75 75 75 75 75 Weight kg 0 046 0 063 0 069 0 130 0 137 Dimensions h x d x w mm 50x16x52 50x16x74 50x16x74 60x16x117 60x16x117 181 Triax taps STT series 5 2400 MHz CLASS STT 1 8 STT 1 10 STT 1 12 STT 1 16 STT 1 20 STT 1 24 348108 348110 348112 348116 348120 348124 Frequency range MHz 5 2400 5 2400 5 2400 5 2400 5 2400 5 2400 Outputs pcs 1 1 1 1 1 1 Insertion loss 5 40 MHz dB lt 2 2 lt 1 7 lt 1 5 lt 1 2 lt 1 2 lt 1 2 40 1000 MHz dB lt 2 2 lt 1 9 lt 1 7 lt 1 2 lt 1 2 lt 1 2 1000 1750 MHz dB lt 3 2 lt 2 2 lt 2 2 lt 1 9 lt 1 9 lt 1 9 1750 2150 MHz dB lt 4 7 lt 3 2 lt 2 17 lt 2 2 lt 2 2 lt 2 2 2150 2400 MHz dB lt 5 0 lt 3 5 lt 3 2 lt 2 5 lt 29 lt 2 5 Tap loss 5 40 MHz dB 8 5 2 0 11 0 2 0 12 0 2 0 15 0 2 0 20 0 42 0 24 0 2 0 40 1000 MHz dB BD ID 10 0 1 5 12 0 1 5 15 0 41 5 20 0 41 5 24 0 1 5 1000 1750 MHz dB 8 0 1 5 10 0 1 5 12 0 1 5 15 0 41 5 20 0 41 5 24 0 1 5 1750 2150 MHz dB 8 0 2 0 10 0 2 0 12 0 2 0 15 0 2 0 20 0 2 0 24 0 2 0 2150 2400 MHz dB 8 5 2 0 10 5 2 0 12 0 2 0 15 0 2 0 20 0 42 0 24 0 2 0 Isolation 5 40 MHz dB gt 18 0 gt 25 0 gt 28 0 gt 28 0 gt 32 0 gt 32 0 40 1000 MHz dB gt 20 0 gt 22 0 gt 25 0 gt 25 0 gt 30 0
330. ts 4 x SAT 4 x SAT 1 x Ter Number of outputs 4 x SAT 4 x SAT 1 x Ter Input frequency standard MHz 950 2200 950 2200 47 862 Input frequency with return path MHz 87 862 Gain dB 15 2 19 950 2 22 adjustable on each polarity dB 25 2000 2 Noise figure dB 6 dB typ 6 dB typ lt 85 7 dB max 7 dB max Connectors F con female female female Attenuation adjustment dB 0 10 0 10 0 20 2 dB Tilt fixed dB 5 6 Equalizer dB 0 18 Isolation between amplifiers dB gt 35 235 Return loss dB gt 10 gt 10 Impedance Ohm 15 75 Max output level 3 order according to DIN45004B dBuV 118 2 order according to DIN45004A1 dBuV 112 CTO CSO 42 channels GEUN 101 Output level IMA 35 dB dBuV 110 110 DC through pass Yes Yes Return path Frequency range dBuv 5 30 5 55 5 65 Gain dB active or passive Attenuation adjustment dB 0 20 2 dB Overall DC through pass Yes Yes Main voltage VDC 15 1 151 15 2 dB Power current mA lt 270 lt 270 Max current per connector mA 500 500 300 Temperature range C 0 50 0 50 0 50 Dimensions H x D x W mm 145 x 138 x 36 145 x 138 x 36 234 x 138 x 36 147 Triax multiswitches Technical data Earth bonding bars for TMS switches 4 way bar 5 way bar 8 way bar 153057 153058 153059 Number of connectors 4 5 8 Connectors F con female to female female to female female to female Remarks Technical data Earth bonding bars with push on connectors TYPE 6 way bar 8 w
331. ut 5 40 MHz dB gt 16 0 gt 18 0 gt 18 0 gt 16 0 gt 16 0 gt 18 0 40 470 MHz dB gt 18 0 gt 18 0 gt 18 0 gt 16 0 gt 16 0 gt 18 0 470 750 MHz dB gt 17 0 gt 18 0 gt 17 0 gt 16 0 gt 16 0 gt 16 0 750 862 MHz dB gt 17 0 gt 18 0 gt 17 0 gt 16 0 gt 16 0 gt 16 0 Shielding efficiency VHF UHF dB gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 gt 100 0 Hum modulation 10 A dB gt 66 gt 66 gt 66 gt 66 gt 66 gt 66 Power pass connection In out In out In out In out In out In out DC throughpass A VAC 10 60 10 60 10 60 10 60 10 60 10 60 Connectors F connector F connector F connector F connector F connector F connector Certification CE Ce Ce CE CE Ce Impedance Ohm 75 75 75 75 75 75 Weight kg Dimensions h x d x w mm 125x 75x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 e Fix TLD bracket for wall mounting of splitters Part No 80262 187 Triax taps TLT series outdoor Outdoor trunk taps with frequency ranges from 5 to 1000 MHz All ports impedance 75 Ohm In out current passing 10 A 60 VAC The 100 dB RFI integrity is maintained by the use of tongue and groove design and with a stainless steel mesh RFI gasket Continual power through between input and output Aluminum alloy housing is finished with a baked acrylic paint to protect from elements Neoprene sealed and nickel plated brass for all 5 8 port entry and taps
332. ut connectors F quick F con male male male Output connector F con female female female Frequency range SAT MHz 950 2200 950 2200 950 2200 Frequency range TER MHz 5 862 5 862 5 862 Pass through SAT Loss dB D 2 D 2 D 2 Pass through TER Loss dB T2 12 122 Attenuation SAT dB 0 to 10 O to 10 D to 10 Isolation dB gt 30 dB typ gt 30 dB typ gt 30 dB typ 25 dB min 25 dB min 25 dB min Isolation SAT TER dB gt 30 dB typ gt 30 dB typ gt 30 dB typ 20 dB min 20 dB min 20 dB min Impedance Ohm 75 75 75 Return loss SAT TER dB gt 10 0 gt 12 0 gt 10 0 gt 12 0 gt 10 0 gt 12 0 Output level dBuV 105 105 105 Noise figure dB lt 7 lt 7 lt 7 DiSEqC control DiSEqC DiSEqC 1 0 DiSEqC 1 0 DiSEqC 1 0 Tone frequency kHz 2244 22 4 22 4 Tone burst option A or B Selectable via switch Selectable via switch Selectable via switch Power supply voltage VDC 11 5 19 11 5 19 11 5 19 Power supply current mA lt 65 mA lt 65 mA lt 65 mA Max current pass mA 300 300 300 Temperature range oC 0 50 0 50 0 50 Dimensions H x D x W mm 113 x 66 x 22 mm 113 x 66 x 22 mm 149 x 66 x 22 mm 145 Triax Districom 4000 multiswitches Districom taps and splitters Taps and splitters allow you to easily support any distribution type with a minimum of units cables and connectors TDR 200 Splitter TDD 110 Tap Technical data Districom tap and splitter
333. ut frequency ranges 120 306 or 306 858 MHz Input frequency range 950 2150 MHz Programmable LNB control on each module Modulation 16 32 64 128 256 QAM Adjustable symbol rate TDH 732 amp TDH 733 Multi language menu TDH QAM module Technical data TDH QPSK QAM modules DVB C master DVB C master DVB C master DVB C master TDH 730C TDH 731C TDH 732C TDH 733C adj symbol rate adj symbol rate Part No 490730 490731 490732 490733 Modulator type QAM QAM QAM QAM Input frequency range MHz 920 2150 920 2150 920 2150 920 2150 Input level EON 45 84 45 84 45 84 45 84 Return loss dB gt 10 gt 10 gt 10 gt 10 Aerial input SAT F F F F Aerial loop through SAT Yes F Yes F Yes F Yes F Demolator Type QPSK QPSK QPSK QPSK Symbol rate Mbps 2 40 SCPC MCPC 2 40 SCPC MCPC Adjustable Adjustable Viterbi decoder 1 2 2 8 3 4 5 6 7 8 1 2 2 3 3 4 5 6 7 8 1 2 2 3 3 4 5 6 7 8 1 2 2 3 3 4 5 6 7 8 Reed Solomon decoder 204 188 t 8 204 188 t 8 204 188 t 8 204 188 t 8 Modulator Output mode QAM 16 32 64 QAM 16 32 64 QAM 16 32 64 QAM 16 32 64 128 256 128 256 128 256 128 256 Output control Normal inverted Normal inverted Normal inverted Normal inverted random random random random Output frequency range MHz 306 858 120 306 306 858 120 306 Output level dBuV 97 97 97 97 LNB contro
334. vV 8 cB tilt e Standard attenuator pads for gain and tilt adjustment as well as interstage attenuation and tilt functions HEA 38 LP1 MP1 amp LA1 MA 1 Triax distribution amplifiers HEA 38 LP2 MP2 amp LA2 MA2 HEA 38 LP1 line powered 322003 HEA 38 MP1 mains powered 322006 HEA 38 LA1 line powered 322015 HEA 38 MA1 mains powered 322018 HEA 38 LP2 line powered 322009 HEA 38 MP2 mains powered 322012 HEA 38 LAZ line powered 322021 HEA 38 MA2 mains powered 322024 Forward path Forward path bandwidth depending on diplexer modules MHz 47 862 47 862 Gain 47 862 MHz dB 38 38 38 38 Attenuation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Equalisation by pads LP1 MP1 amp LP2 MP2 or adjustable att LA1 MA1 amp LA2 MA2 dB 0 18 0 18 Linearity dB ed 3rd order DIN 45004 B dBuvV 124 127 2nd order DIN 45004 A1 dBuV 122 124 CTB 42 ch CENELEC flat 8 dB tilt dBuvV 108 5 111 110 5 113 CTB 42 ch CENELEC by 6 GB interstage att flat 8 dB tilt dBuyuV 108 110 110 112 CSO 42 ch CENELEC dBuvV 112 114 Noise figure 47 862 MHz dB 5 6 5 5 6 5 Noise figure by 6 GB interstage attenuation 47 862 MHz dB 6 7 6 7 Return loss 40 MHz dB 18 1 5 oct 18 1 5 oct Return path Return path bandwidth depending on diplexer modules MHz 5 65 5 65 Gain dB 23 23 Attenuation by pa
335. w cost and low power consumption e For SMATV HEF 845 without return path and with spin potentiometers instead of jumper matrixes Technical data on HEF series HEF 845 HEF 845C 323071 HEF 845 CL 323074 323068 Frequency range selected VHF I on RP off MHz 40 862 40 862 40 862 selected VHF I off RP on MHz 5 65 85 862 5 65 85 862 Gain forward Gain 862 MHz dB 36 36 36 Attenuator at input 2 dB steps dB 0 20 pot 0 16 0 16 Attenuator elements interstage dB 0 6 0 6 0 6 Gain return path Gain 60 MHz dB 1 5 27 1 5 27 Attenuator elements at input dB 0 2 4 6 50 0 2 4 6 50 Attenuator elements at output dB 0 3 6 9 0 3 6 9 Amplitude response forward 40 862 MHz VHF I on dB 1 5 1 5 Line equalizer at input dB 0 18 pot Line equalizer 2 3 dB steps dB 0 16 0 16 Slope interstage dB 0 7 0 7 0 7 Amplitude response return path 5 60 MHz dB 1 5 1 5 Equalizer element interstage dB 0 3 6 0 3 6 Random noise Forward VHF I on dB 5 0 5 5 5 5 Return path VHF I off dB 6 0 6 0 Return loss 40 MHz 1 5 dB octave dB gt 14 gt 14 gt 14 Output level forward IMR2 IMR3 gt 60 dB dBuV 114 123 114 123 114 123 CSO gt 60 dB 42 ch Slope D dB dBpuV 109 111 109 111 109 108 CTB gt 60 dB 42 ch Slope 0 7 dB dBuyV 108 110 108 110 111 110 Output level return path IMR2 IMR3 gt 60 dB dBuvV 104 115 104 115 RF connectors 75 Oh
336. ward 40 862 MHz VHF I on dB 1 5 1 5 1 5 1 5 Fix slope dB 1 1 1 1 Line equalizer at input dB Line equalizer 2 3 dB steps dB Slope interstage dB Amplitude response return path 5 60 MHz dB 1 0 Equalizer element interstage dB Random noise Noise figure dB 4 5 4 5 6 0 4 5 Forward VHF I on dB Return loss 40 MHz 1 5 dB octave dB gt 14 gt 14 gt 14 gt 14 Output level forward IMR2 IMR3 60 dB dBuv 100 113 105 113 90 103 92 103 CSO CTB 60 dB 42 ch flat dBuV 95 98 100 100 86 89 90 90 Output level return path IMR2 IMR3 60 dB dBuvV RF connectors 75 Ohm Input F female F female F female F female Output F female F female F female F female Test point input bi directional dB Test point output directional dB Operating conditions Max RF level EMC dBuvV 105 105 105 105 Supply voltage V 230 10 230 10 230 10 230 10 Power consumption W 3 5 3 5 Operating temperature C 25 55 25 55 25 55 25 55 Protection class II Il Il Il Degree of protection IP 20 20 20 20 Dimensions WxHxD mm 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50 Weight kg 0 65 0 65 0 65 0 65 Packing unit 1 pcs carton box 1 pcs carton box 1 pcs carton box 1 pcs carton box Reference standards Product standards safety EMC RoHS 2002 95 EG compliant EN 50083 3 Class 2 EN 50083 1 EN 60065 EN 50083 2 161 Triax indoor distribution amplifiers N IFA distribution amplifie
337. without booster 116 331424 SCF 24 15A3 comb K24 57 314066 SCS F7000 66 mast filter ch 66 58 300111 TCM 08A Basic Unit with booster 116 331425 SCF 25 15A3 comb K25 57 314067 SCS F7000 67 mast filter ch 67 58 490615 TCMA 615 DSB VHF mono 113 331426 SCF 26 15A3 comb K26 57 314068 SCS F7000 68 mast filter ch 68 58 490616 TCMA 616 DSB UHF mono 113 331427 SCF 27 15A3 comb K27 57 314069 SCS F7000 69 mast filter ch 69 58 490617 TCMA 617 DSB VHF stereo 113 331428 SCF 28 15A3 comb K28 57 364100 SCT 100 IF IF converter 122 490618 TCMA 618 DSB UHF stereo 113 331429 SCF 29 15A3 comb K29 57 153061 Self amalgamating tape black roll with 10m 74 490673 TCMA 673 VSB mono ch 2 69 S N gt 54db 113 331430 SCF 30 15A3 comb KOD 57 737036 Shelving for 19 TCC cabinet not painted 124 490674 TCMA 674 VSB stereo ch 2 69 S N gt 54db 113 331431 SCF 31 15A3 comb K31 57 251496 Shelving for TCMO08 TMF512 cabinet 124 490611 TCSA 611 DSB VHF mono 114 331482 SCF 32 15A3 comb K32 57 130001 Single wireset spare parts 70 490612 TCSA 612 DSB UHF mono 114 331433 SCF 33 15A3 comb K33 57 452090 Spare RF connection cable 20 cm 111 490613 TCSA 613 DSB VHF stereo 114 331434 SCF 34 15A3 comb K34 57 452091 Spare RF connection cable 35 cm 111 490614 TCSA 614 DSB UHF stereo 114 331435 SCF 35 15A3 comb K35 57 153065 SST 21 Black 74 490648 TCSA 621 DSB VHF mono MHz 27 32 114 331436 SCF 36 15A3 comb K36 57 133010 Stay ring 30 50 mm 69 490649 TCSA 622 DSB UHF
338. y Is B PAL Seychelles PAL China D PAL Singapore B PAL Colombia M NTSC South Africa l PAL Cyprus B PAL South Korea M NTSC Czechsolvakia D K SECAM PAL Spain B G PAL Nicam Teletext Denmark B PAL Nicam Teletext Sri Lanka B G PAL Egypt B SECAM Sweden B G PAL Nicam Teletext Faroe Islands DK B PAL Switzerland B G PAL FM FM Teletext Finland B G PAL Nicam Teletext Tahiti KI SECAM France E L SECAM Teletext Taiwan M NTSC Gambia l PAL Thailand B PAL Germany B G PAL FM FM Teletext Trinidad M NTSC Germany prev East B G SECAM PAL Tunisia B SECAM Gibraltar B PAL Turkey B PAL Teletext Greece B G PAL United Arab Emirates B G PAL Hong Kong l PAL Nicam United Kingdom l PAL Nicam Teletext Hungary B G amp D K PAL Nicam Uruguay N PAL MTS Budapest USA M NTSC MTS CC Iceland B PAL Venezuela M NTSC India B PAL Yugoslavia B H PAL Indonesia B PAL Zimbabwe B PAL Iran H SECAM Ireland l PAL Nicam Teletext Israel B G PAL Nicam Teletext Italy B G PAL FM FM Teletext Jamaica N SECAM Japan M NTSC Matrix Jordan B PAL Kenya B PAL Korea M NTSC Luxembourg B G PAL NICAM Teletext S Madeira B PAL S Mm D ly more Madagascar B SECAM E Malaysia B PAL ly Malta B G PAL m O re S l m p Mauritius B SECAM Mexico M NTSC MTS CC Monaco L G SECAM PAL Morocco B SECAM 250 Technical appendix 8 Signal level mV to dBuV 0 100 40 3 55 11 125 102 1 0 0 0
339. y range Low band MHz 950 1950 950 1950 950 1950 950 1950 High band MHz 1100 2150 1100 2150 1100 2150 1100 2150 Output connector type 75Q female 75Q female 75Q female 75Q female Output VSWR room temp 2 0 1 max 2 0 1 max 2 1 1 max 2 0 1 max Local oscillator Frequency Low band GHz 9 75 9 75 9 75 9 75 High band GHz 10 6 10 6 10 6 10 6 Frequency stability MHz 2 5 1 40 60 C 2 5 1 40 60 C 2 5 1 40 60 C 2 5 1 40 60 C Phase noise room temperature DBc Hz 60 1 kHz max 60 1 kHz max 50 1 kHz max 60 1 kHz max DBc Hz 80 10 kHz max 80 10 kHz max 75 10 kHz max 80 10 kHz max DBc Hz 100 100 kHz max 100 100 kHz max 95 100 kHz max 100 100 kHz max Conversion performance room temp Conversion gain typ dB 50 50 50 50 max dB 62 62 62 62 Gain variation over operating band dB 5 p p typ 5 p p typ 5 p p typ 5 p p typ Gain flatness across 26 MHz segm dB 1 0 typ 1 0 typ 1 0 typ 1 0 typ Spurious level dBm 60 max 60 max 60 max 60 max Noise figure Typ dB 0 3 0 3 0 3 0 3 Max dB 0 6 0 6 0 6 0 6 Image rejection dB 40 min 40 min AO min 40 min Cross polarization isolation dB 25 typ 20 min 25 typ 20 min 25 typ 20 min 25 typ 20 min Power requirements DC current consumption typ mA 140 160 140 110 Ope
340. yehtylene which is resistant to thermal fluctuations and sunlight UV radiation The cable housing contains an impedance transformer 300 75 Ohm Furthermore the boom is provided with a strong mast bracket to enable mounting on the mast without using any tools Application Triax standard range of aerials covers the following VHF and UHF frequency bands Frequency Range Band Frequency MHz VHF BI 47 68 VHF BII 87 108 VHF BIII 174 230 UHF BIV 470 622 UHF BV 622 862 more information in Technical Appendix page 250 Types of Aerials Triax range of BIII aerials is manufactured in many different types as the following MT MTD MTL MTH MTHD MTHV MTHV Standard horizontal mounting mast bracket Standard with dual reflector horizontal mounting mast bracket Standard vertical mounting mast bracket Lightweight horizontal or vertical mounting mast bracket Lightweight with dual reflector horizontal mounting mast bracket 3 and 4 elements lightweight window bracket horizontal or vertical mounting 5 elements or FM omni lightweight window bracket horizontal mounting Reception Channel TV 2 4 Radio FM TV TV TV 9 12 21 39 40 69 Terrestrial reception Aerials BI VHF 8 9 BII DAB FM 10 11 BIII VHF 12 15 BIV V UHF 16 24 Combi 25 26 UFO 21 28 NMT and GSM 29 Indoor 30 Triax band I aerial VHF
341. ype SC type SC type SC type SC type SC type Remarks w filter window w filter window bracket bracket Digi 6 6 elem wideband Digi 10 10 elem 16 Technical data Digi 14A Digi 14W Digi 14W Triax Digi band IV V aerial UHF All of the Digi aerials are provided with the snap lock dipole house made from blue UV resistant plastic which protects the balun with capacitive signal transfer against corrosion The aerials are provided with adjustable elevation mast brackets designed for masts up to 60 mm Digi 18 w support boom Digi 18A Digi 18W UHF UHF UHF UHF UHF 108340 108341 108612 108360 108361 Channel 21 37 21 69 21 69 21 37 21 69 Band BIV BIV V BIV V BIV BIV V Elements pcs 14 14 14 18 18 Gain dBi 13 5 13 5 13 5 14 5 14 5 Front to back ratio dB 20 20 29 25 25 Beamwidth hor deg 21 21 21 18 18 Windload N 58 54 54 65 59 Weight kg 0 80 0 77 0 77 1 05 1 05 Material Alu Alu Alu Alu Alu Dimensions length mm 1182 967 967 1836 1446 width mm 420 420 420 420 420 Connector SC type SC type SC type SC type SC type Remarks w filter w support boom Digi 14 SA ESS ESE mE MO O O S S l O Digi 14 elem Digi 18 elem 17 Triax Yagi band IV V aerial UHF TRIAX Yagi aerials have been designed for UHF reception and are available in band IV ch 21
342. z dB 750 862 MHz dB Shielding efficiency VHF UHF dB Hum modulation 10 A dB Power pass connection 5 8 Supply voltage V 12 24 65 Fuse Automatic DC throughpass ANA 2 5A mA max 100 Connectors F con F con Certification CE CE Impedance Ohm 75 75 Weight kg Dimensions h x d x w mm Remarks Power inserter Power inserter incl 1 2m cable for cameras with jackplug 197 Triax power supplies IFP 50x housing Technical data on Triax power supplies NT 50 241 NT 130 241 IFP 501 IFP 502 IFP 503 IFP 504 IFP 505 336150 336154 339501 339502 339503 339504 339505 Band VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF VHF UHF Frequency range MHz 47 862 47 862 47 862 47 862 47 862 47 862 47 862 Inputs pcs 1 1 1 1 1 1 1 Outputs pcs 1 1 1 2 1 2 1 Through loss dB 1 0 1 0 1 0 4 0 1 0 4 0 1 0 Voltage V DC 24 24 12 12 24 24 5 Max power mA DC 50 130 85 85 45 45 45 Main voltage V AC 230 230 230 230 230 230 230 Power W 2 6 3 3 3 3 2 Connectors IEC IEC F con F con F con F con F con Certification CE CE CE CE CE CE CE Impedance Ohm 75 75 75 75 75 75 75 Weight kg 0 4 0 4 0 4 0 4 0 4 Dimensions h x d x w mm 61x44x118 61x44x118 61x44x118 61x44x118 61x44x118 Remarks 198 a TP 3851 602 60 Technical data on Triax power supplies Triax power supplies e ma ton EE GO 651 350
343. zed 38 and 42 mm steel masts 50 mm hot galvanized masts Type Mast Mast Mast Mast Mast Mast Mast 38 mm 38 mm 38 mm 38 mm 38 mm 38 mm 42 mm Part No 140030 140113 140031 140112 140110 140111 140025 Diameter mm 38 38 38 38 38 38 42 Length m 1 5 3 0 3 0 4 0 6 0 2 0 2 0 Thickness mm 10 1 5 1 5 1 5 1 5 1 5 1 5 Max bending moment Nm 540 540 540 540 540 540 Weight kg Packing QTY pcs 10 1 10 1 1 10 1 Remarks DIN 2394 DIN 2394 for composition Technical data on hot galvanized 42 and 50 mm steel masts Type Mast Mast Mast Mast Mast Mast Mast 42 mm 42 mm 50 mm 50 mm 50 mm 50 mm 50 mm Part No 140115 140114 140028 140029 140008 140120 140126 Diameter mm 42 42 50 50 50 50 50 Length m 3 0 6 0 2 0 3 0 4 0 6 0 3 0 Thickness mm 2 0 2 0 2 0 2 0 2 0 2 0 2 0 Max bending moment Nm 1250 1250 1540 1540 1540 1540 Weight kg Packing QTY pcs 1 1 10 1 1 1 1 Remarks DIN 2394 DIN 2394 for for DIN 2394 DIN 2394 composition composition 62 Mast for mounting on brackets roof beams 50 mm masts for extention brackets Pipe holders for bottom pipe Camping mast for indoor roof mounting Technical data on 50 mm bottom steel masts and camping masts Mast Mast Pipe holders Camping mast 50 mm 50 mm f bottom pipe indoor 140121 140122 140128 140135 Diameter mm 50 50 52 16 20 Length m 3 0 6 0 1 6 Thickness mm 2 0 2 0 0 5 Max bending moment
Download Pdf Manuals