1. AS NZS 3548 Class A VCCI Class A EN 55024 EN300 386 EN 50082 1 EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 NEBS Compliant Safety Compliance e UL 60950 1 1st Edition e CAN CSA C22 2 No 60950 1 1st Edition EN 60950 1 1st Edition e IEC 60950 1 1st Edition LED Indicators e AC OK Input power to the power supply is OK e PS OK Output power from the power supply is OK 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 8 of 11 Data Sheet a Table 6 lists the safety and compliance information for the Cisco Catalyst 2350 Series Switches Table 6 Safety and Compliance Feature Specification Safety Certifications e UL60950 1 e C UL to CAN CSA 22 2 No 60950 1 TUV GS to EN 60950 1 e CB to IEC 60950 1 with all country deviations e CE Marking e CCC for PS FRU Electromagnetic Emissions e FCC Part 15 Class A Certifications e EN 55022 Class A CISPR22 Class A CNS13438 Class A applicable only to FRU power supplies AS NZS CISPR22 Class A e EN55024 e GR 1089 CORE Class A EN 300 368 e MIC e CE Marking e China applicable only to FRU power supplies NEBS e GR 63 CORE GR 1089 CORE Level 3 Type 2 4 and Wall Mount e AT amp T TP76200 Checklist e TCG NEBS Checklist ETSI EN 300 019 Storage Class 1 2 Transportation Class 2 3 In Use Class 3 2 Environmental Reduction of Hazardous Substances ROHS 5 No
2. duplex mode and 10BASE T 100BASE TX and 1000BASE T indication as well as switch level status LEDs for system and bandwidth utilization e Jumbo frames 9216 bytes are available for advanced data and video applications requiring very large frames 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 4 of 11 Data Sheet oT Network Management Tools The Cisco Catalyst 2350 Series Switches offer both a command line interface CLI for detailed configuration and Cisco Network Assistant a PC based tool for quick centralized view of the network through an easy to use GUI In addition CiscoWorks LAN Management Solution LMS supports the 2350 Series for network wide management Cisco Network Assistant A PC based network management application designed for small and medium sized business SMB networks with up to 250 users Cisco Network Assistant offers centralized network management and configuration capabilities Cisco Network Assistant features an intuitive GUI where users can easily apply common services across Cisco switches routers and access points Cisco Network Assistant is a tool for e Configuration management e Troubleshooting advice e Inventory reports e Event notification e Network security settings e Password synchronization e Drag and drop Cisco IOS Software upgrades e Secure wireless For detailed information about Cisco Network Assistant visit http www cisco
3. reserved This document is Cisco Public Information Page 5 of 11 Data Sheet ee E Figure 3 Product Specifications Cisco Catalyst 3560 SFP Interconnect Cable Table 2 lists product specifications for the Cisco Catalyst 2350 Series Switches Table 2 Specifications for the Cisco Catalyst 2350 Series Switches Description Specification Performance Switching Fabric 128 Gbps DRAM 128 MB FLASH 64 MB VLANs 128 VLAN IDs 4000 Jumbo Frames 9216B Forwarding rate 101 2 Mpps MAC security and QoS scalability numbers depend on the type of template used in the switch Default Access VLAN Default Template Template Template Template MAC address 4K 12K 6K Connectors and Cabling 1000BASE T SFP based ports RJ 45 connectors 2 pair Cat 5 UTP cabling 1000BASE SX SFP based ports LC fiber connectors multimode fiber 10GBASE SR CX4 LRM X2 based ports SC fiber connectors single mode or multimode fiber Ethernet management port RJ 45 connectors 2 pair Cat 5 UTP cabling Management console port RJ 45 to DB9 cable for PC connections Power Connectors Internal power supply connector The internal power supply is an autoranging unit The internal power supply supports input voltages between 100 and 240VAC Use the supplied AC power cord to connect the AC power connector to an AC power outlet Indicators Per port status LEDs link integrity disa
4. 4 10GBASE CX4 X2 Module X2 10GB LRM 10GBASE LRM X2 Module Spare Power Cords for the Cisco Catalyst 2350 Series Switches CAB AC Power Cord 110V CAB 16AWG AC AC Power cord 16AWG CAB ACA Plug Power Cord Australian 10A CAB ACE Power Cord Europe CAB ACI Power Cord ltalian CAB ACR Power Cord Argentina CAB ACS Power Cord for Switzerland CAB ACU Power Cord UK CAB JPN Power Cord Japan CAB L620P C13 US Power Cord 250VAC 15A NEMA L6 20 to C13 US CAB L620P C13 JPN Power Cord 250VAC 15A NEMA L6 20 to C13 JAPAN CAB IND Power Cord India CAB SFP 50CM SFP Interconnect Cable 50 cm Spare Rack Mount Kits for the Cisco Catalyst 2350 Series Switches RCKMNT E 1RU Rack Mount Kit 1 RU for Catalyst 3750 E RCKMNT E MISC RekMnt 1RU 23in 24in ETSI WallMnt for Cat 3750 E and 3560 E For More Information For more information about the Cisco Catalyst 2350 Series Switches visit http www cisco com en US products hw switches index html or contact your local account representative 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 10 of 11 Data Sheet Americas Headquarters Asia Pacific Headquarters Europe Headquarters C l S C re Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV i San Jose CA Singapore Amsterdam The Netherlands Cisco has more than 200 offices worldw
5. Afeafe CISCO Data Sheet Cisco Catalyst 2350 Series Switches The Cisco Catalyst 2350 Series Switches Figure 1 are a line of standalone top of rack server aggregation switches for the data center This series offers 48 10 100 1000 downlink ports with two 10 Gigabit Ethernet uplinks and an AC or DC power supply The Cisco Catalyst 2350 Series Switches offer a line rate nonblocking solution in a one rack unit 1 RU form factor Figure 1 Cisco Catalyst 2350 Series Switches Features e 48 10 100 1000 downlink ports with two 10 Gigabit Ethernet X2 uplink ports e Cisco TwinGig Converter Module for migrating uplinks from Gigabit Ethernet to 10 Gigabit Ethernet e Modular fan and modular AC or DC power supply e Out of band Ethernet management port along with RS 232 console port Switch Configurations Table 1 shows the configurations for the Cisco Catalyst 2350 Series Switch Table 1 Cisco Catalyst 2350 Series Switch Configurations Product Name Description Cisco Catalyst 2350 48TD S 48 Ethernet 10 100 1000 ports and 2 X2 10 Gigabit Ethernet uplinks 265W AC power supply Cisco Catalyst 2350 48TD SD 48 Ethernet 10 100 1000 ports and 2 X2 10 Gigabit Ethernet uplinks 265W DC power supply Cisco Catalyst 2350 Series Software The 2350 Series switches are available with basic quality of service QoS access control lists ACLs and security 2009 Cisco Systems Inc All rights reserved This d
6. CONFIG MIB e CISCO MEMORY POOL MIB e CISCO PAGP MIB e CISCO PING MIB CISCO PROCESS MIB e CISCO RTTMON MIB e CISCO STP EXTENSIONS MIB e CISCO SYSLOG MIB e CISCO TCP MIB e CISCO VLAN IFTABLE RELATIONSHIP MIB e CISCO VLAN MEMBERSHIP MIB e CISCO VTP MIB ENTITY MIB ETHERLIKE MIB e IF MIB IGMP MIB IPMROUTE MIB OLD CISCO CHASSIS MIB e OLD CISCO FLASH MIB e OLD CISCO INTERFACES MIB e OLD CISCO IP MIB e OLD CISCO SYS MIB e OLD CISCO TCP MIB OLD CISCO TS MIB PIM MIB RFC1213 MIB RFC1253 MIB RMON MIB RMON2 MIB SNMP FRAMEWORK MIB e SNMP MPD MIB e SNMP NOTIFICATION MIB e SNMP TARGET MIB e IEEE 802 3x full duplex on 10BASE T 100BASE TX and 1000BASE T ports IEEE 802 1D Spanning Tree Protocol IEEE 802 1p CoS Prioritization IEEE 802 1Q VLAN IEEE 802 3 10BASE T specification IEEE 802 3u 100BASE TX specification IEEE 802 3ab 1000BASE T specification IEEE 802 3z 1000BASE X specification 1000BASE T 1000BASE SX e SNMPv2 MIB e TCP MIB e UDP MIB Standards e EEE 802 1s e 10GBASE SR e EEE 802 1w e 10GBase CX4 e EEE 802 3ad e 10GBase LRM RMON and II standards e SNMPv1 SNMPv2c and SNMPv3 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 7 of 11 Data Sheet oT Table 4 lists the power supply compatibility matrix for all different models of Cisco Catalyst 2350 Series Switches Table 4 Power Specifications
7. P automates the creation of Cisco Fast EtherChannel groups or Gigabit EtherChannel groups to link to another switch router or server e Automatic media dependent interface crossover MDIX automatically adjusts transmit and receive pairs if an incorrect cable type crossover or straight through is installed 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 2 of 11 Data Sheet e Unidirectional Link Detection Protocol UDLD and Aggressive UDLD allow unidirectional links caused by incorrect fiber optic wiring or port faults to be detected and disabled on fiber optic interfaces Availability and Scalability The Cisco Catalyst 2350 Series Switches are equipped with a robust set of features that allow for network scalability and higher availability This is achieved through a complete suite of Spanning Tree Protocol enhancements that aim to maximize availability in a Layer 2 network Enhancements to the standard Spanning Tree Protocol such as Per VLAN Spanning Tree Plus PVST Uplink Fast and Port Fast maximize network uptime e IEEE 802 1s w Rapid Spanning Tree Protocol RSTP and Multiple Spanning Tree Protocol MSTP provide rapid spanning tree convergence independent of spanning tree timers and also offer the benefit of Layer 2 load balancing and distributed processing e Rapid Per VLAN Spanning Tree RPVST allows rapid spanning tree reconvergence ona per VLAN spanning tree basis
8. between Cisco and any other company 0812R Printed in USA C78 521169 00 02 09 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 11 of 11
9. bled activity speed and full duplex indications System status LEDs system and bandwidth utilization indications Dimensions Inches Centimeters H x Wx D Catalyst 2350 48TD 1 75 x 17 5x 18 1 4 4 x 44 5 x 46 Weight Pounds Kilograms Catalyst 2350 48TD 18 8 8 6 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 6 of 11 Data Sheet oT Environmental Ranges e Operating temperature 32 to 113 F 0 to 45 C e Storage temperature 13 to 158 F 25 to 70 C Relative humidity operating 0 to 95 noncondensing Relative humidity nonoperating 10 to 85 noncondensing e Operating altitude up to 10 000 ft 3049 m e Storage altitude up to 15 000 ft 4573 m Acoustic Noise International Organization for Standardization ISO 7779 bystander position operating to an ambient temperature of 30 C Catalyst 2350 48TD 45 dB Mean Time Between Failure MTBF Catalyst 2350 48TD 166 907 hours Table 3 lists the management and standards support for the Cisco Catalyst 2350 Series Switches Table 3 Management and Standards Support for Cisco Catalyst 2350 Series Switches Management BRIDGE MIB e CISCO CDP MIB e CISCO CLUSTER MIB e CISCO CONFIG MAN MIB CISCO ENTITY FRU CONTROL MIB e CISCO ENVMON MIB e CISCO FLASH MIB e CISCO FTP CLIENT MIB e CISCO IGMP FILTER MIB e CISCO IMAGE MIB e CISCO IP STAT MIB e CISCO L2L3 INTERFACE
10. com go cna CiscoWorks LAN Management Solution LMS CiscoWorks LMS is a suite of powerful management tools that simplify the configuration administration monitoring and troubleshooting of Cisco networks CiscoWorks LMS integrates these capabilities into a world class solution for improving the accuracy and efficiency of your operations staff while increasing the overall availability of your network LMS supports over 400 different device types including the Cisco Catalyst 2350 Series Switches LMS provides e Network discovery topology views end station tracking and VLAN management e Real time network fault analysis with easy to deploy device specific best practice templates e Hardware and software inventory management centralized configuration tools and Syslog monitoring e Network response time and availability monitoring and tracking e Real time device link and port traffic management analysis and reporting For detailed information about CiscoWorks LMS visit http www cisco com en US products sw cscowork ps2425 index html Cisco Catalyst 3560 SFP Interconnect Cable The Cisco Catalyst 3560 SFP Interconnect Cable see Figure 3 provides for a low cost point to point Gigabit Ethernet connection between 2350 Series switches The 50 cm cable is an alternative to using SFP transceivers when interconnecting 2350 Series switches through their SFP ports over a short distance 2009 Cisco Systems Inc All rights
11. for Cisco Catalyst 2350 Series Switches Description C3K PWR 265WAC C3K PWR 265WDC Max Output Power 265W 265W Input Voltage Range and Frequency 100 240 VAC 50 60 Hz 36 VDC to 72 VDC Input Current 5 2 5A lt 5A 72 VDC lt 10A 36 VDC Output Ratings 12V 22A 12V 22A Output Holdup Time 20 ms minimum gt 2ms 48 VDC Power Supply Input Receptacles IEC 320 C13 N A IEC60320 C14 Power Cord Rating 15A 12A 100 VDC Table 5 lists the specifications of all the power supplies supported by the Cisco Catalyst 2350 Series Switches Table 5 Power Supply Specifications for the Cisco Catalyst 2350 Series Switches Product Specifications Power Supply C3K PWR 265WAC C3K PWR 265WDC Physical Specifications H x W x D 1 65 x 6 0 x 11 4 in H x W x D 1 65 x 6 0 x 11 4 in Weight 3 3 Ib 1 5 kg Weight 3 5 Ib 1 6 kg Total Output BTU 907 BTU hr 265W 907 BTU hr 265W Note 1000 BTU hr 290W Operating Temperature 23 to 113F 5 to 45T Storage Temperature 40 to 158F 40 to 70T Relative Humidity Operating 10 to 85 noncondensing Relative Humidity Nonoperating 0 to 95 noncondensing Altitude 10 000 ft 3000 meters up to 45 MTBF Calculated MTBF must be greater than 300 000 hrs using Telcordia SR 332 Method 1 Case 3 Demonstrated MTBF is 500 000 hrs with 90 confidence level EMI and EMC Compliance FCC Part 15 CFR 47 Class A ICES 003 Class A EN 55022 Class A CISPR 22 Class A
12. ide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices CCDE CCENT Cisco Eos Cisco HealthPresence the Cisco logo Cisco Lumin Cisco Nexus Cisco StadiumVision Cisco TelePresence Cisco WebEx DCE and Welcome to the Human Network are trademarks Changing the Way We Work Live Play and Learn and Cisco Store are service marks and Access Registrar Aironet AsyncOS Bringing the Meeting To You Catalyst CCDA CCDP CCIE CCIP CCNA CCNP CCSP CCVP Cisco the Cisco Certified Internetwork Expert logo Cisco IOS Cisco Press Cisco Systems Cisco Systems Capital the Cisco Systems logo Cisco Unity Collaboration Without Limitation EtherFast EtherSwitch Event Center Fast Step Follow Me Browsing FormShare GigaDrive HomeLink Internet Quotient IOS iPhone iQuick Study IronPort the IronPort logo LightStream Linksys MediaTone MeetingPlace MeetingPlace Chime Sound MGX Networkers Networking Academy Network Registrar PCNow PIX PowerPanels ProConnect ScriptShare SenderBase SMARTnet Spectrum Expert StackWise The Fastest Way to Increase Your Internet Quotient TransPath WebEx and the WebEx logo are registered trademarks of Cisco Systems Inc and or its affiliates in the United States and certain other countries All other trademarks mentioned in this document or website are the property of their respective owners The use of the word partner does not imply a partnership relationship
13. ise Specifications Office Product Spec 48dBA at 30 refer to ISO 7779 Telco CLEI code Warranty Limited Lifetime Warranty Service and Support Cisco and its partners can help you deploy a robust dependable Cisco desktop switching solution by taking a lifecycle approach that addresses all aspects of deploying operating and optimizing a complex solution including people processes and technology Whether you are migrating your existing Cisco desktop switching solution or deploying a new solution this approach helps align business and technical goals throughout the solution lifecycle Upgrading from one Cisco IOS Software feature set IP Base or IP Services to another IP Services or Advanced IP Services involves the software activation process described in this document Customers must purchase a feature set specific Cisco SMARTnet Service contract to help ensure service coverage for newly activated Cisco IOS Software feature sets Cisco and its partners are specialists in Cisco desktop switching products and technologies business analysis and project management Cisco services are available through various service programs designed to help accelerate customer success throughout the network lifecycle For more information about Cisco Services see Cisco Technical Support Services or Cisco Advanced Services Ordering Information Table 7 lists ordering information for the Cisco Catalyst 2350 Series Switches To place an
14. ocument is Cisco Public Information Page 1 of 11 Data Sheet a 10 Gigabit Ethernet Uplinks and the Cisco TwinGig Small Form Factor Pluggable Converter The 2350 Series switches feature wire speed 10 Gigabit Ethernet uplink ports for high bandwidth applications relieving congestion and helping ensure smooth delivery of data The TwinGig converter see Figure 2 converts a 10 Gigabit Ethernet X2 interface into two Gigabit Ethernet Small Form Factor Pluggable SFP ports This way customers can initially use the switch with Gigabit Ethernet uplinks and later implement 10 Gigabit Ethernet uplinks as business demands change without having to upgrade the access layer Figure 2 Cisco TwinGig Adapter Converting 10 Gigabit Ethernet X2 Interface into Two Gigabit Ethernet SFP Interfaces Modular Power Supplies Cisco Catalyst 2350 Series switches have one power supply slot and support the following power supplies e C3K PWR 265WAC 265WAC power supply e C3K PWR 265WDC 265WDC power supply Primary Features and Benefits Ease of Use in Deployment Ease of use features include e Dynamic Host Configuration Protocol DHCP autoconfiguration of multiple switches through a boot server eases switch deployment e Autonegotiation on all ports automatically selects half or full duplex transmission mode to optimize bandwidth e Dynamic Trunking Protocol DTP facilitates dynamic trunk configuration across all switch ports e Port Aggregation Protocol PAg
15. order visit the Cisco ordering homepage at http www cisco com en US ordering or13 or8 order_customer help how to order listing html 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 9 of 11 Data Sheet a Table 7 Ordering Information for the Cisco Catalyst 2350 Series Switches Cisco Catalyst 2350 Series Switch Product Number Product Description Catalyst 2350 48TD S 48 10 100 1000 ports 2 X2 based 10 Gigabit Ethernet ports 128 Gpbs wire rate switch fabric Field replaceable 265WAC power supply and fan tray 1 RU fixed configuration multilayer switch Catalyst 2350 48TD SD 48 10 100 1000 ports 2 X2 based 10 Gigabit Ethernet ports e 128 Gpbs wire rate switch fabric e Field replaceable 265WDC power supply and fan tray e 1 RU fixed configuration multilayer switch Power Supplies and Fan Module for the Cisco Catalyst 2350 Series Switches C3K PWR 265WAC Catalyst 3750 E 265WAC power supply C3K PWR 265WDC Catalyst 3750 E 265WDC power supply C3K BLWR 60CFM Fan Module for the Catalyst 3750 E TwinGig Converter Module for the Cisco Catalyst 2350 Series Switches CVR X2 SFP TwinGig Converter Module SFPs for the Cisco Catalyst 2350 Series Switches GLC T 1000BASE T SFP GLC SX MM GE SFP LC connector SX transceiver 10GB X2 Module for Cisco Catalyst 2350 Series Switches X2 10GB SR 10GBASE SR X2 Module X2 10GB CX
16. sco routers and Cisco Catalyst desktop switches e Generic On Line Diagnostics GOLD checks the health of hardware components and verifies proper operation of the system data and control plane at run time and boot time e VLAN1 minimization allows VLAN1 to be disabled on any individual VLAN trunk e Internet Group Management Protocol IGMP Snooping for IPv4 and IPv6 MLD v1 and v2 Snooping provide fast client joins and leaves of multicast streams and limit bandwidth intensive video traffic to only the requestors e Cisco VLAN Trunking Protocol VTP supports dynamic trunk configuration across all switches e Remote Switch Port Analyzer RSPAN allows administrators to remotely monitor ports in a Layer 2 switch network from any other switch in the same network e For enhanced traffic management monitoring and analysis the embedded Remote Monitoring RMON software agent supports four RMON groups history statistics alarms and events e Layer 2 Traceroute eases troubleshooting by identifying the physical path that a packet takes from source to destination e Trivial File Transfer Protocol TFTP reduces the cost of administering software upgrades by downloading from a centralized location e Network Timing Protocol NTP provides an accurate and consistent time stamp to all intranet switches e A comprehensive and convenient visual management system is provided by multifunction LEDs per port for port status half duplex and full
17. ting administrator traffic during Telnet and SNMP sessions SSH Protocol and the cryptographic version of SNMPv3 require a special cryptographic software image because of U S export restrictions 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 3 of 11 Data Sheet e Bidirectional data support on the Switched Port Analyzer SPAN port allows the Cisco intrusion detection system IDS to take action when an intruder is detected e TACACS and RADIUS authentication facilitates centralized control of the switch and restricts unauthorized users from altering the configuration e Multilevel security on console access prevents unauthorized users from altering the switch configuration e Bridge protocol data unit BPDU guard shuts down Spanning Tree Port Fast enabled interfaces when BPDUs are received to avoid accidental topology loops e Spanning Tree Root Guard STRG prevents edge devices not in the network administrator s control from becoming Spanning Tree Protocol root nodes e IGMP filtering provides multicast authentication by filtering out nonsubscribers and also limits the number of concurrent multicast streams available per port Management and Control Features The Cisco Catalyst 2350 Series Switches come with a set of management and control features These features include the following e Cisco IOS Software CLI support provides common user interface and command set with all Ci
18. without requiring the implementation of spanning tree instances Quality of Service The Cisco Catalyst 2350 Series Switches offer the following QoS features e 802 1p class of service CoS and differentiated services code point DSCP field classification is provided using marking and reclassification on a per packet basis by source and destination IP address or Layer 4 TCP UDP port number e Cisco control plane and data plane QoS ACLs on all ports help ensure proper marking on a per packet basis e Four egress queues per port help enable differentiated management of up to four traffic types across the switch e Shaped Round Robin SRR scheduling helps ensure differential prioritization of packet flows by intelligently servicing the ingress queues and egress queues e Weighted Tail Drop WTD provides congestion avoidance at the ingress and egress queues before a disruption occurs e Strict priority queuing helps ensure that the highest priority packets are serviced ahead of all other traffic e The Cisco committed information rate CIR function provides bandwidth in increments as low as 8 Kbps e Up to 64 aggregate or individual policers are available per Fast Ethernet or Gigabit Ethernet port Security The Cisco Catalyst 2350 Series Switches support a basic set of security features including the following e Secure Shell SSH Protocol and Simple Network Management Protocol Version 3 SNMPv3 provide network security by encryp