Home
DataVideo PD-1 power distribution unit PDU
Contents
1. 66 PD 1 19 Rack Mount Power Center User s Guide http www datavideo tek com Rev 230506 Warnings and Precautions Read all of these warnings and save them for later reference Follow all warnings and instructions marked on this unit Unplug this unit from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning Do not use this unit in or near water Do not place this unit on an unstable cart stand or table The unit may fall causing serious damage Slots and openings on the cabinet top back and bottom are provided for ventilation To ensure safe and reliable operation of this unit and to protect it from overheating do not block or cover these openings Do not place this unit on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit should not be placed in a built in installation unless proper ventilation is provided This product should only be operated from the type of power source indicated on the marking label of the AC adapter If you are not sure of the type of power available consult your Datavideo dealer or your local power company Do not allow anything to rest on the power cord Do not locate this unit where the power cord will be walked on rolled over or otherwise stressed an extension cord must be used with this
2. info Datavideo Technologies Co Ltd 10F 176 Jian Yi Rd Chung Ho City Taipei Hsien Taiwan 235 Tel 886 2 8227 2888 service datavideo com tw www datavideo com tw Datavideo Technologies China Co 2F D 2 Lane 777 West Guangzhong Rd Zhabei District Shanghai China Tel 86 21 5603 6599 service datavideo cn www datavideo cn Datavideo Technologies S PTE Ltd No 100 Lorong 23 Geylang 01 03 D Centennial Bldg Singapore 388398 Tel 65 6749 6866 info datavideo sg www datavideo info Datavideo Hong Kong Limited G F 26 Cross Lane Wanchai HK Tel 852 2833 1981 info datavideohk com www datavideohk com
3. unit make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension 6010 5 rating Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes Never push objects of any kind into this unit through the cabinet ventilation slots as they may touch dangerous voltage points or short out parts that could result in risk of fire or electric shock Never spill liquid of any kind onto or into this unit Except as specifically explained elsewhere in this manual do not attempt to service this product yourself Opening or removing covers that are marked Do Not Remove may expose you to dangerous voltage points or other risks and will void your warranty Refer all service issues to qualified service personnel Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions a When the power cord is damaged or frayed b When liquid has spilled into the unit c When the product has been exposed to rain or water d When the product does not operate normally under normal operating conditions Adjust only those controls that are covered by the operating instructions in this manual improper adjustment of other controls may result in damage to the unit and may often require extensive work by a qualified technician to restore the unit to normal operation e When the produc
4. 12V and 5V power outputs from an 110V 220V AC Input The PD 1 is an essential accessory for Datavideo Mobile Studio applications together with the SE 800 switcher LCD recorders the PD 1 makes the integration of a Mobile Studio become easier and more professional Built in time delay power on control to initiate each DC output terminal in sequence and installed with an auto recover fuse in every terminal to safely protect every working device Supports input power source from AC 110V or 220V different models or input from the DC 12V 30Amp input terminal What s in the Package PD 1 main unit XLR 4P male to 4P Female 1 2m cable x 2 2 1mm DC to DC Plug to 1 2m cable x 3 2 1mm DC to DC Plug to 0 8m cable x 1 2 1mm DC to DC Plug to 0 7m cable x 2 2 1mm DC to DC Plug to 0 5m cable x 1 2 1mm DC to DC Plug to 0 3m cable x 1 AC Power cord Oe OY Ol a ee a User s Guide Front Panel Select Input source Two bypass AC outputs from DC or AC Two cooling fans External DC12Volt 30A Input External AC input Note AC 110 and 220 are different models Power Switch On Off Switch Powers the PD 1 On Off when using AC Power N B From DC Power the On Off Switch is redundant AC In with built in fuse AC Inlet for connecting to suitable mains power outlet 100 120V or 220 240V according to model The socket contains a fuse holder fitted with a 10A fuse N B Please ensure that you use the correct AC Volta
5. DAC 30 MP 6000 SE 800 SE 800AV PD 1 DC 5 1A DC 12V 2A DC 12V 4A DC 12V 5A DC 12V 7A Specification ITEM Specification VOLTAGE AC 110V 220 Separate models RANGE 100 120V AC 220 240V AC INPUT FREQ 50Hz 60Hz POWER 110V 5A 220V 4A Separate models VOLTAGE DC 12V 5 POWER 12V 300W VOLTAGE 5V 12V depends on different loading increase voltage will some decreasing OUTPUT RANGE 5V 3 12V 3 CURRENT 5V 1A 12V 2A 4A 5A 7A INDICATOR LED NOISE RATIO OVERLOAD PROTECTION YES AUTO RECOVER FUSE WORKING 5 45 C TEMPERATURE DIMENSION 440mm 214mm 44 mm 1U height 19 rack WEIGHT 3 8Kg Service and Support It is our goal to make your products ownership a satisfying experience Our Supporting staff is available to assist you in setting up and operating your system Please refer to our web site www datavideo tek com for answers to common questions support requests or contact your local office below Datavideo Corporation USA 12300 U East Washington Blvd Whittier CA 90606 USA Tel 1 562 696 2324 contactus datavideo us www datavideo us Datavideo Technologies Europe BV Californiedreef 26 3565 BL Utrecht The Netherlands Tel 31 30 261 9656 info datavideo nl www datavideo info Datavideo UK Limited Unit 2 Waterside Business Park Hadfield Glossop Derbyshire SK13 1BE UK Tel 44 1457 851000 sales datavideo co uk www datavideo
6. e Positive DC Out 12V 2A 2 12V 2A DC Output via 2 1mm In Line Sockets Centre Positive DC Out 12V 4A 4 12V 4A DC Output via 2 1mm In Line Sockets Centre Positive XLR DC12V 5A Output 2 1m DC 12V 2A Output 2 1m DC 12V 2A Output 2 1m DC12V Jack output x 2 for total 4A max rating DC 5 1A I M G s DC 12V 2A N DC 12V 2A 2 FM A DC Out 12V 7A 2 12V 7A DC Outputs 1 2 1mm In Line Sockets Centre Positive and 1 x 4 Pin XLR Socket Pin 4 Positive Pin 1 Ground DC Out 12V 5A 1 x 12V 5A Output via 4 Pin XLR Socket Pin 4 Positive Pin 1 Ground AC Outlet 1 5A 110 3A 240V AC Outlet at same voltage as AC Input 110 120 220 240V according to model N B Socket is redundant when PD 1 is powered from DC Ground Terminal When connecting this unit to any other component make sure that it is properly grounded by connecting this terminal to an appropriate point When connecting use the socket and be sure to use wire with a cross sectional area of at least 1 0 mm2 Datavideo Product Voltage Requirements This table is a guideline for Datavideo Products if you are using products from other manufacturers please check their voltage requirements carefully before connecting to the DAC 200 DAC 100 BAC 03 VP 332 DAC 15 DAC 10 DAC 6 DAC 5 TLM 70D TLM 404 TLM 700 TLM 702 TLM 350 SE 500 DVK 100 RMC 140 ITC 100 STC 100 DN 100 CP 100
7. ge for the PD 1 that you have purchased 110V and 220V are different models If you are in any doubt please contact your supplier or your local Datavideo office listed at the back of this manual Cooling Fan The PD 1 has two built in cooling fans please ensure that these are not blocked and that some airflow is available AC Outlet 110 240 5A 2 x AC Outlet at same voltage as AC Input 110 120 220 240 according to model N B Sockets are redundant when PD 1 is powered from DC DC In The PD 1 can be powered from a suitable 12V power source When working from DC the PD 1 will not regulate the power outlets Please ensure that the 12V power source that you use is regulated you intend to run the PD 1 from a car or van power outlet make sure that a suitable regulator is used on the power feed Pin 4 should be wired positive and Pin 1 should be ground N B The AC Outlets are not active when the PD 1 is powered via the DC In N B The On Off switch is redundant when the PD 1 is powered from a DC supply Input Select AC DC The Input select switch can be set to AC or DC according to the power input that you intend to use N B Do not connect AC and DC power inlets at the same time Rear Panel Bypass AC Output 2 1m DC 5V 1A Output XLR DC12V 2 1m DV12V 7A Output 2 1m DC12V Jack output x 2 for total 4A max rating DC Out 5 1A 5V 1A DC Output via 2 1mm In Line Socket Centr
8. t has been dropped or the cabinet has been damaged f When the product exhibits a distinct change in performance indicating a need for service 10 11 12 13 Warranty Datavideo warrants that the equipment it manufactures shall be free from defects in material and workmanship for a period of 12 months from the date of product purchased If equipment fails due to such defects Datavideo will at its option repair or provide a replacement for the defective part or product Equipment that fails after the warranty period has been operated or installed in a manner other than that specified by Datavideo or has been subjected to abuse or modification will be repaired for time and material charges at the Buyer s expense This warranty does not affect your statutory rights within the Country of purchase For EU Customers only WEEE Marking This symbol on the product indicates that it will not be treated as household waste It must be handed over to the applicable take back scheme for the recycling of electrical and electronic equipment For more detailed information about the recycling of this product please contact your local Datavideo Office CONTENTS INTRODUCTION WHAT S IN THE PACKAGE FRONT PANEL CONNECTIONS REAR PANEL CONNECTIONS DATAVIDEO PRODUCT VOLTAGE REQUIREMENTS SPECIFICATIONS SERVICE AND SUPPORT O ON O FP OO Introduction The PD 1 is a 19 Rack Mount Power Centre It is able to supply multiple