1. Quick Installation optional These connections are optional Your UPS will function properly without these connections El Tel DSL Surge Suppression select models Using telephone cords connect your wall jack to the UPS jack marked LINE or IN and your equipment to the UPS jack marked EQUIP or QUT This will protect your equipment from surges over a telephone line but you should make sure that your equipment is also protected against surges on the AC line A USB Communications Use any USB cable to connect the USB port of your computer to the USB port of your UPS Download the PowerAlert UPS monitoring software program appropriate for your operating system from www tripplite com and install it on your computer Basic Operation Use the ON OFF button to do three things O Switch your UPS s Operating Mode While your UPS is plugged into a live AC outlet press the ON OFF button and hold it until you hear a beep about 2 seconds to toggle between the following operating modes Choose your UPS s operating mode based on the regional guidelines in Step 3 of the Quick Installation section e UPS Mode ENABLES battery backup UPS Conditions The UPS charges its battery and supplies power at its receptacles when it is receiving utility line power If utility power fails the UPS provi
2. 1 800 SAV LEAD ou 1 800 8 BATTERY 1 800 8 228 8379 ou visiter www rbrc com pour toutes informations sur le recyclage Ne pas jeter les batteries dans un feu e N essayez pas d ajouter de batteries externes au syst me UPS Installation rapide HU Branchez votre syst me UPS dans une prise de secteur Une fois branch le syst me UPS effectue un autotest Consultez la section Exploitation de base pour comprendre les r sultats de l autotest B Brancher votre ordinateur le moniteur et autres quipements au syst me d alimentation continue sans coupure Votre syst me d alimentation sans coupure est con u pour supporter seulement des quipements informatiques Vous surchargerez votre syst me d alimentation continue sans coupure si vous con nectez des quipements haute consommation lectrique tels que des appareils domestiques ou imprimantes laser des sorties assurant un secours de batterie d alimentation continue sans coupure Les mod les de s lection comportent des sorties sp ciales clairement indiqu es sur le panneau arri re qui assurent uniquement une protection contre les surtensions non avec batterie de secours pr vue pour les imprimantes laser et autres appareils haute consommation lectrique El Choix du mode d exploitation du syst me UPS Appuyez sur le commutateur ON OFF marche arr t pour faire basculer
3. Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB at 1MHz AC Protection Modes H to N H to G N to G N 0 M FCC RADIO TV INTERFERENCE NOTICE C US Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC UL1778 Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this x s equipment does cause harmful interference to radio or television reception which can be determined by turning the device off and on Im portantes I nstrucciones de segu ridad 10 the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not express
4. NOTIFICACI N DEL COMIT FEDERAL DE COMUNICACIONES FCC SOBRE INTERFERENCIAS DE RADIO Y TELEVISI N Nota Este equipo se ha probado y cumple con los l mites para dispositivos digitales de Clase B en conformidad con la Parte 15 de las reglas de la FCC Estos limites est n dise ados para brindar protecci n razonable en contra de interferencia da ina cuan S EE do el equipo se opera en una instalaci n dom stica Este equipo genera utiliza y puede radiar energ a de radiofrecuencia y de Im portantes consig nes de secu rite no ser instalado y usado de acuerdo con las instrucciones suministradas en el manual de operaci n puede causar interferen cias en las comunicaciones de radio No obstante no existe garant a alguna de que estas interferencias no vayan a ocurrir en una instalaci n particular Si este equipo causara interferencias peligrosas en la recepci n de se ales de radio o televisi n lo cual puede determinarse encendiendo y apagando el equipo se aconseja que el usuario intente corregir la situaci n tomando una o m s de lassiguientes medidas reorientar o trasladar la antena receptora incrementar la distancia entre el equipo y el recep 1 1 tor conectar el equipo a una toma el ctrica o circuito diferente al que est conectado el receptor solicitar la asistencia del dis nstal lation rapide tribuidor o de un t cnico de radio y televisi n El usuario debe utilizar en este producto cables y conectores blindados Cualquier camb
5. Si votre protecteur de modem t l copieur prouve des difficult s veuillez communiquer avec le Service la client le de Tripp Lite 1111 W 35th Street Chicago Illinois 60609 composez le 1 773 869 1234 pour toute information relative aux r pa rations et la garantie La compagnie de t l phone peut vous demander de d connecter ce mat riel du r seau t l phonique jusqu ce que le probl me soit corrig ou que vous vous soyez assur que l quipement n est pas d fectueux 5 Ce mat riel ne peut pas tre utilis avec une ligne d appareil payant fournie par la compagnie de t l phone Les connexions aux lignes partag es sont assujetties des tarifs d tat Communiquez avec votre commission d tat ou votre entreprise de services publics pour plus d information LIMITATION DU MAT RIEL POUR LES MOD LES POSS DANT LE LABEL D INDUSTRIE CANADA AU CANADA SEULEMENT Avis Le label d Industrie Canada identifie le mat riel homologu Cette homologation signifie que le mat riel est conforme aux exigences de protection d utilisation et de s curit des r seaux de t l communications prescrites dans les documents d exi gences techniques de mat riel terminal Le minist re ne garantit pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel les utilisateurs devraient s assurer qu il est permis de le brancher au r seau de la compagnie de t l communications locale Le mat riel d
6. a durante fallas del servicio el ctrico y bajas de voltaje a su equipo conectado Tambi n protegen su equipo contra sobretensiones perjudiciales y ruido en la l nea Los modelos exclusivos tienen salidas Surge only S lo para sobretensiones identificadas en la parte posterior del UPS que proporcionan protecci n contra sobetensiones a los perif ricos sin comprometer valiosa energ a de bater a para alimentarlos durante las fallas del servicio el ctrico Puerto USB a a El puerto USB conecta el sistema UPS a cualquier estaci n de trabajo o servidor USB Al utilizar este puerto el UPS puede comunicar a la computadora el estado de falla de l nea y de nivel bajo de bater a Utilice el software Tripp Lite y el cable USB para guardar autom ticamente sus archivos abiertos y cerrar su sistema durante unainterrupci n en el suministro de la energ a el ctrica Para obtener m s informaci n p ngase en contacto con el departamento de asistencia al cliente de Tripp Lite o consulte el manual del software para la protecci n del suministro de energ a E El Conectores Tel DSL Modelos exclusivos Estos conectores protegen sus equipos contra sobretensiones a trav s de una l nea telef nica La conexi n de su equipo a estos conectores es opcional Su UPS funcionar correctamente a n sin esta conexi n Operaci n b sica continuaci n Sensibilidad de energ a ajuste de voltaje bajo Modelos
7. a trav s de la l nea de servicio Si la energ a de la l nea de servicio falla el sistema UPS proporciona corriente desde sus bater as La luz del indicador v est encendida Ventajas de esta posici n Suministra respaldo de bater a durante apagones 0 bajas de voltaje Modo CHARGE ONLY carga solamente DESHABILITA el respaldo de bater as Condiciones del sistema UPS El sistema UPS carga su bater a y suministra corriente a sus recept culos cuando recibe energ a a trav s de la l nea de servicio La luz del indicador v parpadea Ventajas de esta posici n Contin a el proceso de recargar la bater a cuando est presente la corriente a la vez que se apaga el inversor para prevenir el agotamiento de la bater a durante las sobrecargas y cuando el equipo no se encuentra en uso Operaci n b sica continuaci n Arrancar en fr o el sistema UPS Se puede arrancar en fr o la unidad UPS y utilizarla como fuente aut noma de energ a cuando la energ a el ctrica no est disponible pero nicamente si se encuentra cargada la bater a del sistema UPS Para arrancar en fr o el UPS oprima el bot n ON OFF encendido apagado hasta que oiga un sonido aproximadamente 2 segundos cuando oiga el sonido suelte el bot n La luz del indicador se ilu minar y se proporcionar a sus recept culos el suministro de CA invertida de la energ a acumulada en las bater as Apagar el sistema UPS Opr
8. ces mises en garde annule la garantie Mises en garde relatives l emplacement du syst me UPS e Installez votre syst me UPS l int rieur loin de l humidit de la chaleur excessive des impuret s conductrices de la poussi re et de la lumi re directe du soleil e Pour un meilleur fonctionnement maintenez la temp rature ambiante entre 0 C et 40 C 32 F et 104 F s Laissez suffisamment d espace tout autour du syst me UPS pour maintenir une bonne ventilation Mises en garde relatives au raccord du syst me UPS s Branchez directement votre syst me UPS une prise de courant alternatif munie d un contact de mise la terre Ne branchez pas votre syst me UPS sur lui m me car ceci l endommagera e Ne modifiez pas la prise du syst me UPS et n utilisez pas un adaptateur qui rendrait la connexion de mise la terre du syst me inop rante N utilisez pas de rallonges lectriques lors du branchement du syst me UPS une prise c a Votre garantie sera annul e si le branchement s effectue l aide de suppresseurs de surtension autres que ceux fabriqu s par Tripp Lite e Si votre syst me UPS est aliment par une g n ratrice de courant alternatif celle ci devra fournir un courant filtr et sans parasites convenant au mat riel informatique Mises en garde relatives au raccord de l quipement e Ne raccordez pas les syst mes UPS Tripp Lite des appareils de soutien vital si leur dysfonction ou leur d
9. claramente rotuladas en el panel posterior que s lo proporcionan protecci n contra sobretensiones no brindan respaldo de bater a dise adas para impresoras l ser y otros dispositivos de alto consumo El Selecci n del modo de operaci n del UPS Oprima el bot n ON OFF encendido y apagado para alternar el sistema entre los modos UPS LED Y encendido y CHARGE ONLY sola mente recarga LED v parpadeando Elija el modo de operaci n seg n su ubicaci n EE UU Canad y Europa Occidental e Deje el sistema siempre en el modo UPS El resto de los pa ses Ponga el sistema en el modo CHARGE ONLY 0 carga de bater a solamente cuando no est utilizando los equipos conec tados al mismo ADVERTENCIA Cuando el interruptor est en la posici n CHARGE ONLY carga de bater a solamente el sistema UPS no suministrar energ a de bater a durante un apag n o baja de voltaje e Ponga el sistema en el modo UPS cuando est utilizando los equipos conectados al mismo V ase la secci n Operaci n b sica para obtener una expli caci n m s completa de cada modo Instalaci n r pida optativa Estas conexiones son optativas El sistema UPS funcionar correctamente sin estas conexiones ii Supresi n de sobretensiones en l neas telef nicas DSL modelos exclusivos Utilizando cables de tel fono conecte el enchufe de pared a la conexi n
10. equipment with AC line power during normal operation and battery power during blackouts and brownouts They also protect your equipment against damaging surges and line noise Select models feature Surge only receptacles identified on the back of the UPS which provide peripherals with surge protection without committing precious battery power to support them during blackouts Tel DSL Jacks Select Models These jacks protect your equipment against surges over a telephone line Connecting your equipment to these jacks is optional Your UPS will still work properly without this connection USB Port The USB port connects your UPS to any USB workstation or server Using this port your UPS can communicate line fail and low battery status to your computer Use with Tripp Lite software and any USB cable to automatically save open files and shut down equipment during a blackout Contact Tripp Lite Customer Support or consult your power protection software manual for more information Power Sensitivity Lowline Adjustment Select Models This dial is normally set fully counterclockwise which enables the UPS to protect against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to providing PWM sinewave power from its battery reserves for as long as the distortion is present In some areas with poor utility power or where the UPS s input power comes from a backup generator frequent brownouts and or
11. faillance pourrait causer une panne ou pourrait modifier de mani re significative l ex cution de ces dispositifs e Ne connectez pas de suppresseurs de surtension ou de rallonges lectriques la prise de votre syst me UPS De tels branchements peuvent endommager le syst me UPS et entra ner une annulation de sa garantie tout comme celle couvrant le suppresseur de surtension Mises en garde relatives la batterie e Votre syst me UPS n exige pas d entretien courant Ne l ouvrez pas quelqu en soit la rai son sauf pour remplacer la batterie Il n y a pas de pi ces l int rieur que l utilisateur peut r parer par lui m me Le remplacement de la batterie doit tre confi du personnel de service qualifi Parce que les batteries posent un risque d lectrocution et de br lure caus par une intensit en court circuit lev e veuillez observer les pr cautions appropri es D branchez et mettez le syst me UPS hors circuit avant d effectuer le remplacement des batteries Remplacez les par un nombre identique de batteries du m me type batteries au plomb bac herm tique en utilisant des outils munis de poign es isolantes N ouvrez pas les batteries Veillez ce qu aucun objet ne court circuite les bornes des batteries e LeS batteries du syst me d alimentation continue sans coupure sont recyclables Se r f rer aux r glementations locales pour les conditions de mise au rebut ou aux Etats Unis seulement appeler le
12. la batterie lors des pannes de secteur ou des baisses de tension e Mode CHARGE ONLY D SACTIVE l alimentation lectrique de la batterie tat du syst me UPS Le syst me UPS charge ses batteries et alimente ses prises lorsqu il re oit l alimentation lectrique du secteur Le voyant lumineux V clignote Avantages de ce mode Continuer charger la batterie pendant la mise sous tension tout en d sactivant l on duleur pour emp cher que la batterie ne se d charge durant les pannes secteur lorsque l quipement n est pas utilis Ex cution d un autotest de syst me UPS Votre syst me UPS effectue un autotest lors de son branchement initial Pour qu un nouvel autotest soit ex cut un autre moment laissez le mat riel sous tension Le syst me tant branch et en mode UPS appuyez sur ce bouton et maintenez le enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes puis rel chez le R sultats d un autotest Tous les voyants s allument et le syst me UPS met plusieurs courts signaux pendant qu il passe momentan ment en mode d alimenta tion de secours pour v rifier la charge de la batterie Ce test ne dure pas plus de 10 secondes Si la charge de l onduleur est trop importante le syst me UPS continue mettre un timbre apr s le test Si cela se produit diminuez un peu la charge et ex cutez de nouveau l autotest Si les batteries semblent faibles le voyant lumineux 7 reste all
13. le syst me entre les modes UPS V voyant lumineux allum et CHARGE ONLY rechargement seulement V voyant lumineux clignotant Choisissez le mode d exploitation du syst me en fonction de votre r gion U Canada et Europe de l Ouest e Laissez toujours le syst me UPS en mode UPS Pour tous les autres pays s Laissez le syst me UPS en mode CHARGE ONLY lorsque vous n utilisez pas votre mat riel ATTENTION Lorsque positionn sur CHARGE ONLY le syst me UPS ne fournira pas d alimentation lectrique de la batterie en cas de panne de secteur ou de baisse de tension e Laissez le syst me UPS en mode UPS lorsque vous utilisez votre mat riel Consultez la section Exploitation de base pour obtenir de l in formation d taill e sur chaque mode Installation rapide facultative Ces connexions sont facultatives Votre syst me UPS fonctionnera correctement sans ces connexions U Suppression de surtension T l DSL mod les de s lection l aide de cordons t l phoniques reliez la prise murale au connecteur marqu LINE ou IN entr e du syst me UPS et votre quipement au con necteur UPS marqu EQUIP ou OUT sortie Votre quipement sera prot g contre la surtension manant de la ligne t l phonique mais il faudra vous assurer que votre mat riel branch est galement prot g contre la surtension sur la ligne
14. me UPS est faible Si ce voyant est toujours allum apr s les 12 heures de recharge et l ex cution d un second autotest consul tez le service la client le de Tripp Lite DETECTION DE TENSION D ENTREE BASSE HAUTE MODE LES DE SELECTION Ce voyant vert s allumera si le syst me d ali mentation continue sans coupure d tecte que la tension de ligne d arriv e a chut ou s est lev e au del des niveaux nominaux Un faible son de cliquetis peut tre entendu durant l op ration de d tection Le voyant peut s allumer de mani re intermittente ou rester allum pendant des p riodes de temps prolong es suivant la condition de la tension d arriv e Le voyant est pr vu comme signal uniquement et vous n avez aucune op ration effectuer SURCHARGE MODELES DE SELECTION Ce voyant rouge s al lumera si la capacit du syst me d alimentation continue sans coupure a t d pass e durant son fonctionnement avec l alimentation de la batterie pen dant un autotest ou une coupure de courant Eliminer imm diatement la surcharge des sorties support es par la batterie Autres fonctions Prises CA Alimentation continue sans coupure Surtension sont utilis es pour assurer vos quipements connect s une alimentation lectrique CA durant un fonctionnement normal et une alimentation par batterie pendant O des coupures de courant et des baisses de tension Elles prot gent aussi vos quipements contre des surten
15. syst me une prise de secteur pendant 4 ou 6 heures Si vous laissez les batteries de votre syst me UPS d charg es pendant une p riode de temps extr mement longue elles souffriront d une perte permanente de capacit Entretien Si vous rapportez votre syst me UPS pour un entretien communiquez avec votre concession naire ou votre distributeur Tripp Lite local Celui ci vous r f rera un centre de service Veuillez emballer le syst me UPS en utilisant le MAT RIEL D EMBALLAGE ORIGINAL livr avec l unit Joignez y une lettre d crivant les sympt mes du probl me Si votre syst me UPS est couvert par la garantie joignez y une copie de votre facture Sp cifications La politique de Tripp Lite est de poursuivre l am lioration de ses produits Les sp cifications ci jointes peuvent tre modifi es sans pr avis Mod le BCPRO600 BCPRO850 BCPRO1050 BCPRO1400 S rie AGOM1000USBKSR6 AGOM1050PJR61 AGOM1050PJR61 AGOM1400PSR61 Tension d entr e Fr quence 120V 60 Hz 120V 60 Hz 120V 60 Hz 120V 60 Hz Capacit de sortie VA Watts 600 345 850 600 1050 705 1400 940 Temps de fonctionnement de batterie Charge moiti Pleine charge Minutes 19 7 21 6 23 7 24 8 Temps de recharge de batterie 24H 2 4H 2 4 H 2 4 H Agr ments UL cUL NOM UL cUL NOM UL cUL NOM UL cUL NOM TOUS LES APPAREILS Mode ligne en forme d onde de sortie onde sinusoidale filtr e mode batterie en forme d onde de sortie onde sinus
16. 3 869 1234 para obtener infor maci n acerca de la reparaci n o garant a La compa a de tel fonos puede solicitarle que desconecte este equipo de la red hasta que se haya corregido el problema o se asegure de que el equipo no est funcionando mal 5 Este equipo no podr utilizarse en los servicios telef nicos con monedas La conexi n a l neas telef nicas estar sujeta a las tarifas estatales correspondientes P ngase en contacto con la comisi n de servicios p blicos estatales o con la enti dad proveedora para obtener m s informaci n E ng is h 1 ANEXO DE LIMITACIONES DEL EQUIPO MODELOS CON LA ETIQUETA INDUSTRIAL DE CANAD NICAMENTE EN CANADA Notificaci n La etiqueta industrial de Canad identifica al equipo certificado Esta certificaci n significa que el equipo cumple con los requerimientos de operaci n seguridad y protecci n de las redes de telecomunicaciones tal como se se ala en los doc umentos apropiados sobre los requerimientos t cnicos del equipo terminal El Departamento no garantiza que el equipo oper ara a entera satisfacci n del cliente Antes de instalar este equipo los usuarios se deben asegurar de que se permite conectarse Espa ol 9 a las instalaciones de la compa a local de telecomunicaciones Adem s este equipo debe instalarse utilizando un m todo de conexi n aceptable El cliente debe estar enterado de que el cumplimiento de las condiciones anteriores no podr a prevenir la degrad
17. Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down con nected equipment Run a Self Test Your UPS performs a self test whenever it is first plugged in To have it run a self test at another time leave your connected equipment on With your UPS plugged in and in the UPS mode press and hold this but ton until you hear a beep about 2 seconds then release it Results of a Self Test All the LEDs will be lit and the UPS will emit several short beeps as it momentarily switches to battery to test its charge and load capacity The test will last at most 10 seconds If the inverter is overloaded the UPS will continue to beep after the test if this happens remove some of the load and run the self test again If the batteries seem weak the 1 LED will stay lit and the UPS will continue to beep after the test if this happens let UPS charge its batteries for 12 hours and repeat the test If the condition persists contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Depending on the condition of incoming voltage the LOW HIGH INPUT VOLTAGE DETEC TION LED may or may not be lit Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on LINE POWER This green light wi
18. Owner s Manual BC Pro 120V Input Output Standby UPS Systems A US NOM UL1778 L important Saetynstuctions gt 1 RTS gt L Basic Opera on RR ET Espa ol 9 Fran ais 17 AA ee TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2003 Tripp Lite All rights reserved BC Pro is a registered trademark of Tripp Lite Important Safety Instructions AN SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings e Install your UPS indoors away from excess moisture or heat conductive contaminants dust or direct sunlight For best performance keep the indoor temperature between between 32 F and 104 F 0 C and 40 C Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection Do not use extension cords to connect the UPS to an AC outlet Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to con
19. a Esta luz roja se encender EA continuamente despu s de que el sistema UPS ejecute una autoprueba para indicar que la bater a est casi desgastada Si la luz permaneciera encendida despu s de haber permitido cargarse el UPS durante doce horas y ste haya ejecutado una segunda autoprueba p ngase en contacto con Tripp Lite para solicitar servicio t cnico LOW HIGH INPUT VOLTAGE DETECTION Detecci n de Voltaje de Entrada Bajo Alto Modelos Exclusivos Esta luz verde se encender cuando el UPS detecte que el voltaje entrante de l nea ha ca do por debajo o se ha elevado por encima de los valores nominales Puede escucharse un suave clic durante el proceso de detecci n La luz puede encenderse en forma intermitente o permanecer encendida por per odos m s prolongados dependiendo de la condici n del voltaje entrante La luz s lo tiene fines informativos y no requiere que usted tome ninguna acci n OVERLOAD SOBRECARGA MODELOS EXCLUSIVOS Esta luz roja se encender cuando se haya excedido la capacidad del UPS durante su operaci n con energ a de bater as durante una auto prueba o una falla del servicio el ctrico Desconecte inmediatamente la sobrecarga de las salidas alimentadas por bater a Otras caracter sticas del sistema UPS Tomas AC iil jil Las tomas UPS Surge UPS Sobretensiones se emplean para propor cionar energ a de la l nea de corriene alterna durante la operaci n normal y energ a de bater
20. aci n del servicio en algunas situaciones Las reparaciones del equipo certificado deben ser coordinadas por un representante designado por el proveedor Cualquier reparaci n o alteraci n realizada por el usuario a este equipo o el mal funcionamiento del mismo puede dar origen a que la compa a de telecomunicaciones solicite al usuario que desconecte el equipo Los usuarios deben asegurarse por su propia protecci n de que las conexiones el ctricas a tierra del servicio de suministro 0 las l neas telef nicas y el sistema met lico de tuber as de agua si los hay se conecten de manera conjunta Esta precauci n es particularmente importante en las reas rurales Precauci n Los usuarios no deben tratar de efectuar las conexiones por s POWER PROTECTION mismos deben ponerse en contacto con la autoridad de inspecci n el ctrica correspondiente o con un electricista seg n sea m s apropiado Exploitation de base Sp cifications 1111 W 35th Street Chicago IL 60609 USA Service la client le 773 869 1234 www tripplite com O Tripp Lite 2003 Tous droits r serv s BC Pro est une marque d pos e de Tripp Lite Importantes consignes de s curit AN GARDEZ CES INSTRUCTIONS EN UN LIEU SUR Le pr sent guide contient des instructions et des mises en garde qui doivent tre suivies pendant l installation l exploitation et l entreposage de tous les syst mes UPS Tripp Lite Ne pas tenir compte de
21. ate it Your UPS is now ready for storage If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service Tf returning your UPS for service contact your local Tripp Lite dealer or distributor They will refer you to a service center Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the warranty period enclose a copy of your sales receipt Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Manual del usuario Model BCPRO600 BCPRO850 BCPRO1050 BCPRO1400 Series AGOM1000USBKSR6 AGOM1050PJR61 AGOM1050PJR61 AGOM1400PSR61 Input Voltage Frequency 120V 60 Hz 120V 60 Hz 120V 60 Hz 120V 60 Hz O Output Capacity VA Watts 600 345 850 600 1050 705 1400 940 TO Battery Runtime Half Load Full Load Minutes 19 7 21 6 23 7 24 8 Sistemas de energia ininterrumpible de 120V de entrada salida Battery Recharge Time 2 4 hrs 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL NOM UL cUL NOM UL cUL NOM UL cUL NOM ALL UNITS Output Waveform Line Mode filtered sinewave Output Waveform Battery
22. chronic waveform distortion could cause the UPS to switch to battery too often draining its battery reserves You may be able to reduce how often your UPS switches to battery due to waveform distortion or brownouts by experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform and reduces the voltage point at which it switches to battery NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion and the lower the input voltage the UPS will allow to pass to connected equipment When experimenting with different settings for this dial operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations The experiment should last long enough to assure that all expected line conditions are encountered Basic Operation continued Battery Replacement Door Under normal conditions the original battery in your UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 Storage 8 Service Storage All connected equipment should be turned off then disconnected from the UPS to avoid battery drain Unplug your UPS from its AC receptacle then press and hold its ON OFF button to deactiv
23. cte el sistema UPS a s mismo ya que esto lo da ar e No modifique los conectores del UPS y no utilice un adaptador que pueda eliminar la conexi n a tierra del sistema e No utilice cables de extensi n para conectar el UPS a la toma de CA Si se utiliza otro tipo de supresor de sobretensi n que no sea Tripp Lite para conectar el UPS a la toma de corriente se anular la garant a del sistema e Si el sistema UPS recibe energ a el ctrica por medio de un generador motorizado de CA ste deber proporcionar una salida de corriente limpia y filtrada del tipo utilizado para las computadoras Advertencias sobre la conexi n del equipo e No utilice los sistemas UPS de Tripp Lite en aplicaciones para el sost n de la vida humana donde un fallo pudiera causar anomal as o alterar significativamente el rendimiento del dispositivo del sost n de vida e No conecte supresores de sobretensi n o cables de extensi n a la salida del sistema UPS Esto podr a da arlo as como al supresor de picos e invalidar sus garant as Advertencias sobre las bater as e El sistema UPS no requiere mantenimiento rutinario alguno No abra el UPS por ning n motivo excepto para el reemplazo de las bater as Esta unidad no contiene partes interl ores que puedan ser reparadas por el usuario e S lo debe cambiar las bater as personal t cnico debidamente capacitado Debido a los riesgos de choques el ctricos y quemaduras por la elevada corriente de
24. de Tripp Lite De ese modo se le podr indicar el centro de ser vicio m s cercano Por favor empaque el sistema UPS cuidadosamente utilizando el MATER IAL ORIGINAL DE EMPAQUE incluido con la unidad Adjunte una carta describiendo los s n tomas del problema experimentado Si el sistema UPS se encuentra dentro del per odo de garan t a adjunte una copia de su factura de compra Ficha t cnica de de l utilisateur La pol tica de Tripp Lite es de una mejora continua Estas especificaciones est n sujetas a cambios sin previo aviso Modelo BCPRO600 BCPRO850 BCPRO1050 BCPRO1400 Serie AGOM1000USBKSR6 AGOM1050PJR61 AGOM1050PJR61 AGOM1400PSR61 Voltaje Frecuencia de entrada 120V 60 Hz 120V 60 Hz 120V 60 Hz 120V 60 Hz Capacidad de salida VA Vatios 600 345 850 600 1050 705 1400 940 B C D r Tiempo de respaldo de bater a O NAAA o 119 7 21G S a Syst mes UPS de secours entr e et sortie de 120 V Tiempo de recarga de bateria 2 4 horas 2 4 horas 2 4 horas 2 4 horas Aprobado por UL cUL NOM UL cUL NOM UL cUL NOM UL cUL NOM TODAS LAS UNIDADES Modo de la forma de onda de salida de la linea onda sinusoidal filtrada modo de la forma de onda de salida de la bateria onda 0 sinusoidal PWM supresi n de sobrecarga de CA excede las normas IEEE Cat 587 A y B Atenuaci n de ruidos de CA gt 40 dB C US Menee a 1MHz Modos de Protecci n de CA positivo a neutro positivo a tierra y neutro a tierra U 11 778
25. de secteur c a A Communications USB Utilisez n importe quel c ble USB pour connecter le port USB de votre ordinateur 3 celui de votre syst me UPS T l chargez le logiciel de contr le de syst me UPS PowerAlert adapt votre syst me d exploitation directement du site www tripplite com et installez le dans votre ordinateur Exploitation de base suite D marrage froid de votre syst me UPS Si vos batteries sont charg es vous pouvez d marrer votre syst me UPS froid et l utiliser en tant que source d ali mentation autonome lorsque l alimentation du secteur n est pas disponible Pour effectuer un d marrage froid appuyez sur le commutateur ON OFF et maintenez le enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes puis rel chez le Le voyant lumineux s allume et les prises seront aliment es en tension c a par l nergie emmagasin e dans la batterie de secours Arr t de votre syst me UPS Pour d sactiver le syst me appuyez et maintenez enfonc le commutateur ON OFF quand aucune alimentation du secteur ne passe par ex durant une panne secteur ou lorsque le syst me UPS est d branch Le bouton MUTE TEST sourdine test a deux usages Arr t de l alarme de la batterie du syst me UPS Appuyez sur le bouton et maintenez le enfonc pour mettre l alarme de la batterie du
26. del UPS se alada como LINE l nea o IN l nea de entrada y su equipo con el enchufe del UPS se alado como EQUIP equipo o OUT l nea de salida Lo anterior proteger a su equipo contra sobretensiones en la l nea telef nica Sin embargo deber asegurarse de que su equipo tambi n est protegido contra sobretensiones en la l nea de CA A Comunicaciones USB Utilice cualquier cable USB para conectar el puerto USB de la computadora al puerto USB del UPS Descargue la versi n del programa PowerAlert de con trol del UPS apropiada para su sistema operativo en la direcci n de Internet www tripplite com e inst lelo en la computadora Operaci n b sica Botones Use el bot n ON OFF encendido y apagado para hacer lo siguiente O Cambiar el modo de operaci n del sistema UPS Mientras el UPS est enchufado a una toma de CA accionada oprima el bot n ON OFF encendido y apagado hasta que se oiga un sonido aproximadamente 2 segundos para alternar entre los siguientes modos de operaci n Elija el modo de operaci n del sistema UPS seg n las instrucciones regionales en el paso 3 de la secci n Instalaci n r pida e Modo de UPS HABILITA el respaldo de bater a Condiciones del sistema UPS El sistema UPS carga su bater a y suministra corriente a sus recep t culos cuando recibe energ a
27. des power from its batteries The v indicator light is lit Setting Advantages Provides battery backup during blackouts or brownouts CHARGE ONLY Mode DISABLES battery backup UPS Conditions The UPS charges its battery and supplies power at its receptacles when it is receiving utility line power The v indicator light is flashing Setting Advantages Continues to charge the battery when power is present while turning OFF the inverter to prevent battery depletion during power outages when equipment is not in use Basic Operation continued Cold Start Your UPS You may cold start your UPS and use it as a stand alone power source when utility power is not present providing that the UPS battery is charged To cold start your UPS press and hold the ON OFF button until you hear a beep about 2 seconds then release it The 4 indicator light will illuminate and AC power inverted from stored battery power will be provided at its receptacles Shut Down Your UPS Press and hold the ON OFF button when AC line power is absent i e during a blackout or when the UPS is unplugged to deactivate your UPS Use the MUTE TEST button to do two things Silence the UPS On Battery Alarm Press and hold this button to silence the UPS On Battery alarm a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery Note When the battery is nearly depleted the
28. ent is not malfunctioning 5 This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state D Z D tariffs Contact your state public utility commission or corporation for information Ficha tecn Ica 15 EQUIPMENT ATTACHMENT LIMITATIONS MODELS WITH THE INDUSTRY CANADA LABEL IN CANADA ONLY Notice The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction E ng i sh 1 Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request 1 the user to disconnect the equipment F ran cal S 17 Users should ensure for their own protection that the elect
29. es surtensions sur une ligne t l phonique La connex ion de vos quipements ces jacks est optionnelle Votre syst me d ali mentation continue sans coupure continuera fonctionner correctement sans cette connexion R glage de Sensibilit d alimentation Ligne basse Mod les de s lec tion Ce cadran est normalement positionn 3 fond dans le sens inverse des aiguilles d une montre ce qui permet au syst me d alimentation con tinue sans coupure d assurer la protection contre les distorsions de forme d onde dans son entr e CA Quand une telle distorsion se produit le sys t me d alimentation continue sans coupure passera normalement l ali mentation onde sinuso dale PWM de ses r serves de batterie aussi longtemps que la distorsion est pr sente Dans certaines zones avec une faible alimentation lectrique de service ou dans les endroits o l alimen tation d entr e du syst me d alimentation continue sans coupure provient d un g n rateur de secours des baisses de tension fr quentes et ou une distorsion de forme d onde chronique pourrait provoquer des passages trop fr quents du syst me d alimentation continue sans coupure la batterie puisant les r serves de la batterie Vous pouvez r duire le nombre de pas sages de votre syst me d alimentation continue sans coupure la batterie en raison de distorsion de forme d onde ou de baisse de tension en effec tuant diff rents r glages avec ce cadran Quand le cad
30. exclusivos KON Este dial normalmente est regulado totalmente en el sentido contrario al reloj lo que permite al UPS proteger contra distorsiones de forma de onda NORM DELAY en su entrada de corriente alterna Cuando ocurren dichas distorsiones normalmente el UPS conmutar para proporcionar una onda sinusoidal PWM de energ a de sus bater as de reserva por tanto tiempo como la distorsi n contin e En algunas reas con un suministro de energ a de la red de baja calidad o donde la energ a de entrada del UPS provenga de un generador de respaldo las frecuentes bajas de voltaje y o la cr nica distorsi n de la forma de onda pueden causar que el UPS conmute a alimentaci n por bater as con demasiada frecuencia agotando sus bater as de reserva Es posible que reduzca la frecuencia con que su UPS conmuta a bater as debido a la distorsi n de la forma de onda o a bajas de voltaje experimentando con diferentes ajustes para este dial A medida que el dial es girado en el sentido del reloj el UPS se vuelve m s tolerante a las variaciones en la forma de onda de la energ a de la corriente alterna de entrada y reduce el valor de voltaje al cual conmuta a bater as NOTA A mayor ajuste del dial en el sentido del reloj mayor ser el grado de distorsi n de la forma de onda y menor el voltaje de entrada que el UPS permitir que pasen al equipo conectado Al experimentar con diferentes ajustes para este dial opere el equipo conectado en un m
31. ies in a fire Do not attempt to add external batteries to the UPS Quick Installation H Connect your UPS to an electrical outlet Your UPS will run a self test after it is plugged in See Basic Operation to understand the results of its self test B Plug your computer monitor and other equipment into the UPS system Your UPS is designed to support only computer equipment You will overload your UPS if you connect high power draw equipment such as household appliances or laser printers to outlets providing UPS battery backup Select models fea ture special outlets clearly labeled on the rear panel which provide surge only not battery backup protection designed for laser printers and other heavy draw devices El Select UPS Operating Mode Press the ON OFF button to toggle your UPS between the UPS LED lit and the CHARGE ONLY v LED flashing modes Choose the operating mode based on your loca tion USA Canada amp Western Europe s Leave the UPS in the UPS mode at all times All other countries s Put the UPS in the CHARGE ONLY mode when you are not using connected equipment WARNING When set to CHARGE ONLY the UPS will not provide battery backup during a blackout or brownout e Put the UPS in the UPS mode when you are using connected equipment See Basic Operation section for a complete explanation of each mode
32. ima el bot n ON OFF cuando no exista energ a de l nea de CA por ej durante un apag n o cuando el sistema UPS est desenchufado hasta que se desactive Use el bot n MUTE TEST silenciar probar para realizar dos funciones Silenciar la alarma del UPS en bater a Oprima y mantenga oprimido este bot n para silenciar la alarma del UPS en bater a Se oir entonces una serie de sonidos cortos a los cuales les seguir una breve pausa que se activa cuando el UPS proporciona CA por medio de la bater a Nota Cuando la bater a est casi agotada la alarma indicadora de esta condici n emitir un sonido continuo que no puede silenciarse para advertirle de que deben apagarse de inmediato los equipos conectados Efectuar una autoprueba El sistema UPS ejecuta una autoprueba cuando se conecta por primera vez Para que ste ejecute la autoprueba en otro momento deje activado el equipo conectado al sistema Con el UPS conectado y en el modo UPS oprima este bot n hasta que oiga un sonido aproxi madamente 2 segundos Resultados de una autoprueba Todas las luces LED de indicaci n estar n encendidas y el sistema UPS emitir varios sonidos cortos al cambiar moment neamente a la bater a para hacer la prueba de capacidad de carga y reserva La prueba durar un m ximo de 10 segundos Si el inversor est sobrecargado el sonido en el sistema UPS continuar despu s de la prueba si esto sucediera elimine algo de la carga y ejecu
33. io o modificaci n a este producto no aprobado por parte del responsable del cumplimiento de las normas correspondientes podr a anular la autorizaci n o licencia del usuario para operar el equipo INFORMACI N AL CONSUMIDOR Y REQUISITOS DE LA AGENCIA FCC SOLAMENTE EN EE UU 1 Este equipo cumple con las reglas de la Parte 68 de la FCC En la parte superior o en el fondo de este equipo se encuen tra una etiqueta que contiene entre otros el n mero de registro FCC para este equipo Si se le solicita proporcione esta informaci n a la compa a telef nica 2 Si el protector del fax m dem provoca da os a la red telef nica la compa a de tel fonos podr a descontinuar temporal mente su servicio De ser posible le notificar n por adelantado Sin embargo si no es factible la notificaci n por adelanta E do sta se proporcionar lo antes posible Se le informar sobre su derecho a presentar una queja ante la FCC E ntreposage et entretien 3 La compa a telef nica podr efectuar cambios en sus instalaciones equipo operaciones y procedimientos que afecten la operaci n del equipo Si as sucede se le notificar por adelantado de tal modo que usted tenga la oportunidad de man tener un servicio sin interrupciones 4 Si se experimentan problemas con este protector de fax m dem por favor p ngase en contacto con el departamento de atenci n a clientes de Tripp Lite 1111 W 35th Street Chicago Illinois 60609 tel fono 77
34. ll turn ON whenever your UPS is receiving normal AC line power It will flash while the UPS is in CHARGE ONLY mode to indicate that the UPS will not provide battery backup during a blackout or brownout BATTERY POWER This yellow light will turn ON when your UPS is providing your equipment with battery power Basic Operation continued BATTERY CHARGE This red light will turn ON continuously after the UPS runs a self test to indicate that the UPS s battery is weakly charged If it remains lit after you have allowed the UPS to charge for twelve hours and run a second self test contact Tripp Lite for service LOW HIGH INPUT VOLTAGE DETECTION SELECT MODELS This green light will turn ON when the UPS detects that incoming line voltage has fallen below or risen above nominal levels A gentle clicking sound may be heard during the detection process The light may turn on intermittently or remain on for longer periods depending on the condition of incoming voltage The light is for informational purposes only and no action is required on your part OVERLOAD SELECT MODELS This red light will turn ON when the UPS s capacity has been exceeded while it is operating from battery power either during a self test or during a blackout Remove overload from battery supported outlets immediately Other UPS Features NORM DELAY AC Receptacles UPS Surge receptacles are used to provide your connected
35. los cortocircuitos que presentan las bater as el personal t cnico capacitado debe observar todas las precau ciones pertinentes Desconecte y apague el sistema UPS antes de reemplazar las bater as Utilice herramientas con asas aisladas y reemplace las bater as con el mismo n mero y tipo de bater as nuevas selladas de plomo y cido No abra las bater as No permita que ning n objeto entre en contacto con ambos bordes o terminales de las bater as e Las bater as del UPS son reciclables Consulte la reglamentaci n local para los requisitos de disposici n de desechos para los EE UU solamente llame al 1 800 SAV LEAD o al 1 800 8 BATTERY 1 800 8 228 8379 o visite www rbrc com para obtener informaci n sobre el proceso de reciclaje No deseche las bater as en un incinerador e No agregue bater as externas al sistema UPS Instalaci n r pida H Conecte el sistema UPS a una toma de corriente Al conectarse el sistema UPS ste ejecutar una autoprueba Vea la secci n Operaci n b sica para poder entender los resultados de dicha autoprueba B Conecte su computadora monitor y otros equipos en su sistema UPS Su UPS s lo est dise ado para dar soporte a equipos de c mputo Si conecta equipos de alto consumo de energ a como electrodom sticos o impresoras l ser a las salidas que proporcionan respaldo de bater a de UPS lo sobrecargar Los modelos exclusivos presentan salidas especiales
36. ly approved by the party responsible for y 7 u compliance could void the user s authority to operate the equipment l nstalaci n rapida 11 CONSUMER INFORMATION AND FCC REQUIREMENTS U S A ONLY select models 1 This equipment complies with Part 68 of the FCC rules On the top or bottom of this equipment is a label that contains among other information the FCC registration number for this equipment If requested provide this information to your telephone company ae Bee 2 If your Fax Modem Protector causes harm to the telephone network the telephone company may temporarily discontinue your Operacion basica 12 service If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC 3 Your telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of your equipment If they do you will be given advance notice so as to give you an opportunity to maintain uninterrupted service s s 8 4 If you experience trouble with this Fax Modem Protector please contact Tripp Lite Customer Support 1111 W 35th Street Almacenamiento y servicio 15 Chicago Illinois 60609 Phone 773 869 1234 for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure that the equipm
37. nect your UPS to an outlet s If the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might damage the UPS and will void the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason except battery replacement There are no user serviceable parts inside Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object The UPS batteries are recyclable Refer to local codes for disposal requirements or in the USA only call 1 800 SAV LEAD or 1 800 8 BATTERY 1 800 8 228 8379 or visit www rbrc com for recycling information Do not dispose of the batter
38. odo de prueba seguro de modo que el efecto de cualquier distorsi n de forma de onda en la salida del UPS sobre el equipo pueda evaluarse sin desestabilizar ninguna operaci n cr tica El experimento debe durar lo suficiente para asegurar que se encuentren todas las condiciones de l nea esperadas Puerta para el reemplazo de las bater as En condiciones normales las bater as originales de este sistema UPS tienen varios a os de vida til S lo deber reemplazar la bater a person al t cnico calificado V ase Advertencias sobre las bater as en la sec ci n sobre seguridad de la p gina 11 Almacenamiento y servicio Almacenamiento Todos los equipos conectados se deber n desactivar y a continuaci n desconectar del UPS para evitar el desgaste de la bater a Desenchufe el UPS del recept culo de CA y oprima el bot n ON OFF encendido y apagado hasta que se desactive Ahora ya se puede guardar el UPS Si planea guardar el sistema UPS por un per odo prolongado de tiempo se deber n recargar com pletamente las bater as del sistema UPS cada tres meses conectando el sistema UPS a una toma de corriente alterna CA y permitiendo que se recarguen durante 4 a 6 horas Si deja descargadas las bater as durante un per odo de tiempo prolongado sufrir n una p rdida permanente de capacidad Servicio Si piensa devolver este sistema UPS para efectuar reparaciones p ngase en contacto con su dis tribuidor o representante local
39. oidale MIL modulation d impulsions en largeur suppression de surtensions c a exc de les cat gories A et B de la norme IEEE 587 att nuation de bruit c a gt 40 dB 1 MHz modes de protection c a H N H G N G AVIS DE BROUILLAGE RADIO LECTRIQUE DE LA FCC Note Ce mat riel a t test et s est av r tre conforme aux limites des dispositifs num riques de Classe B conform ment la Partie 15 du r glement de la FCC Ces limites sont con ues pour fournir une installation r sidentielle une protection raisonnable contre les brouillages nuisibles Ce mat riel produit utilise et peut mettre de l nergie de fr quence radio et s il n est pas install et utilis conform ment au guide d instructions celui ci peut causer du brouillage dans les communications radio Cependant il n y a aucune garantie que du brouillage ne se produira pas dans une installation particuli re Si ce mat riel cause une interf rence nocive la r ception radio ou t l vision ce qui peut tre d termin en mettant le dispositif hors tension et puis de nouveau en marche l utilisateur est encourag essayer de corriger l interf rence en utilisant une ou plusieurs des mesures suivantes r orientez ou d placez l antenne de r ception augmentez la distance entre le mat riel et le r cepteur branchez le mat riel dans une prise de courant sur un circuit diff rent de celui sur lequel le r cepteur est branch consultez vot
40. oit galement tre install selon une m thode de connexion acceptable Le consomma teur est averti que la conformit aux conditions ci dessus n emp chera pas la d gradation du service dans certains cas La r paration du mat riel homologu doit tre coordonn e par un repr sentant d sign par le fournisseur La compag nie de t l communications peut demander l utilisateur de d connecter son mat riel la suite de d fauts de fonction nement de ce dernier ou la suite de r parations ou de modifications apport es par l utilisateur Dans l int r t de leur propre s curit les utilisateurs devraient s assurer que la prise de terre du secteur des lignes t l phoniques et du r seau de canalisation d eau si pr sents sont connect s ensemble Cette pr caution peut tre particuli rement importante dans les zones rurales Attention Les utilisateurs ne devraient pas essayer de faire les connexions eux m mes mais devraient plut t communiquer avec un responsable de l inspection lectrique ou un lectricien comp tent 93 2140 200304142
41. ran est tourn dans le sens des aiguilles d une montre le syst me d alimentation continue sans coupure supporte mieux les variations de la forme d onde CA d entr e et r duit le point de tension auquel il passe la batterie REMARQUE Plus le cadran est positionn dans le sens des aiguilles d une montre plus le degr de distorsion de forme d onde sera lev et plus sera basse la tension d entr e que le sys t me d alimentation continue sans coupure laissera passer aux quipements connect s Lors d exp rimentation avec diff rents r glages pour ce cadran utiliser les quipements connect s en mode test de s curit afin que l effet sur les quipements de toutes distorsions de forme d onde dans la sortie du syst me d alimentation continue sans coupure puisse tre valu sans perturber des op rations cruciales L exp rimentation doit durer assez longtemps pour s assur er que toutes les conditions de ligne pr vues sont pr sentes Entreposage et entretien Entreposage Tout le mat riel branch doit tre teint puis d connect du syst me UPS pour viter d puiser la batterie D branchez le syst me UPS de sa prise c a puis pour le d sactiver appuyez et maintenez enfonc le commutateur ON OFF Votre syst me UPS est maintenant pr t tre entrepos Si vous envisagez d entreposer votre syst me UPS pour une p riode prolong e rechargez compl tement les batteries tous les trois mois en branchant le
42. re concession naire ou un technicien exp riment en radiot l vision L utilisateur doit faire usage de c bles et de connecteurs blind s avec ce produit Tous changements ou modifications apport s ce produit qui ne sont pas express ment accept s par la partie respon sable de la conformit aux normes peuvent annuler le droit de l utilisateur d exploiter cet quipement INFORMATION AU CONSOMMATEUR ET EXIGENCES DE LA FCC U SEULEMENT 1 Ce mat riel est conforme la partie 68 du r glement de la FCC Une tiquette situ e sur le dessus ou le dessous de l ap pareil contient entre autres son num ro d enregistrement de la FCC Si on vous le demande veuillez fournir cette informa tion votre compagnie de t l phone 2 Si votre protecteur de modem ou de t l copieur endommage le r seau t l phonique votre compagnie de t l phone peut d cider d interrompre temporairement votre service de ligne Lorsque c est possible ils vous informeront l avance Mais si un pr avis n est pas r alisable vous en serez inform dans les meilleurs d lais Vous serez avis de votre droit de d poser une plainte la FCC 3 Votre compagnie de t l phone peut effectuer des modifications ses installations son quipement ses exploitations ou ses proc dures qui peuvent affecter le fonctionnement de votre mat riel Si cette situation survient vous serez avis l avance pour vous permettre de maintenir un service ininterrompu 4
43. rical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 EE UU Atenci n al cliente 1 773 869 1234 www tripplite com 2003 Tripp Lite Todos los derechos reservados BC Pro es una marca registrada de Tripp Lite Importantes instrucciones de seguridad VAN GUARDE ESTAS INSTRUCCIONES Este manual contiene advertencias e instrucciones importantes que deben seguirse durante la instalaci n operaci n y almacenamiento de todos los sistemas UPS de Tripp Lite De no cumplirse estas advertencias la garant a ser anulada Advertencias sobre la colocaci n del UPS e Instale el sistema UPS bajo techo alejado del calor o la humedad excesivos de los cont aminantes conductivos del polvo o de la luz solar directa e Para lograr el mejor rendimiento mantenga la temperatura interior entre 0 C y 40 C 32 F y 104 E e Mantenga suficiente espacio alrededor del sistema UPS para permitir una ventilaci n adecuada Advertencias sobre la conexi n del UPS e Conecte su sistema UPS directamente a una toma de energ a de CA con conexi n ade cuada a tierra No cone
44. sions et des bruits de ligne nuisibles Les mod les de s lection comportent des prises Surtension seulement indiqu es l arri re du syst me d alimentation continue sans coupure qui assurent aux p riph riques une protection contre les surtensions sans sol liciter la pr cieuse alimentation de la batterie pour les supporter durant les coupures de courant Port USB Le port USB de votre syst me UPS se connecte tout poste de travail ou serveur muni d un port USB En utilisant ce port votre syst me UPS peut transmettre les tats de panne de secteur et de baisse de charge de la bat terie votre ordinateur Utilisez le logiciel et le c blage USB fournis par Tripp Lite pour sauvegarder automatiquement vos fichiers ouverts et tein dre votre mat riel lors d une panne de secteur Communiquez avec le serv ice la client le de Tripp Lite ou consultez le guide de votre logiciel de protection de l alimentation lectrique pour plus de d tails Hf B a Porte de remplacement de la batterie Dans des conditions normales la batterie initiale de votre syst me UPS durera plusieurs ann es Le remplacement de la batterie ne doit tre r al is que par du personnel de service qualifi R f rez vous la rubrique Mises en garde relatives la batterie la section S curit de la page 18 Exploitation de base suite Jacks T l DSL Mod les de s lection Ces jacks prot gent vos quipements contre l
45. syst me UPS en sour dine celle ci met une s rie de courts signaux suivis d une br ve pause lorsque l alimentation lectrique c a est fournie par la batterie Note Lorsque la batterie est presque puis e l alarme de batterie faible met un son continu ne pouvant tre mis en sourdine pour vous avertir de d brancher imm diatement tout votre mat riel informatique Exploitation de base Commutateurs Le commutateur ON OFF marche arr t a trois fonctions Changement du mode de fonctionnement du syst me UPS Le syst me UPS tant branch dans une prise c a appuyez sur le commutateur ON OFF en le maintenant enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes indiquant qu il vous est possible de basculer entre les divers modes de fonctionnement Choisissez le mode de fonctionnement de votre syst me UPS en suivant les instructions s appliquant votre r gion Celles ci figurent l tape 3 de la section Installation rapide e Mode UPS ACTIVE la batterie de secours Etat du syst me UPS Le syst me UPS charge ses batteries et alimente ses prises lorsqu il re oit l alimentation lectrique du secteur Si une panne de secteur ou une baisse de tension se produit le syst me UPS continue de fournir du courant en s alimentant partir de ses batteries Le voyant lumineux V s al lume Avantages de ce mode Fournir l alimentation lectrique de
46. te de nuevo la autoprueba Si la bater a parece estar bastante desgastada el LED HA permanecer encendida y el sonido en el UPS continuar despu s de la prueba si esto sucediera deje que el sistema cargue sus bater as durante 12 horas y repita la prueba Si esto continuara p ngase en contacto con Tripp Lite para solicitar servicio t cnico PRECAUCI N No desenchufe el sistema UPS para probar sus bater as Esto eliminar la conexi n a tierra y podr a introducir picos de tensi n peligrosos en sus conexiones de red Dependiendo de la condici n del voltaje entrante el LED LOW HIGH INPUT VOLTAGE DETECTION DETECCI N DE VOLTAJE DE ENTRADA BAJO ALTO puede estar encendido ono Luces indicadoras Todas las descripciones de luces indicadoras aplican cuando el sistema UPS est encendido y conectado a una toma de CA LINE POWER energ a de l nea Esta luz de color verde se encender cada vez que el sistema UPS est recibiendo energ a de la l nea normal de CA La luz parpadear mientras el sistema UPS est en modo CHARGE ONLY carga solamente para indicar que ste no proporcionar reserva de bater a durante un apag n o una baja de voltaje BATTERY POWER energ a de la bater a Esta luz amarilla se encender cuando el sistema UPS proporcione corriente desde la bater a al equipo conectado al mismo ES Operaci n b sica continuaci n BATTERY CHARGE carga de la bater
47. um et le syst me UPS continue mettre un timbre apr s le test Si cela se produit rechargez les batteries pendant 12 heures et r p tez le test Si cela ne r sout pas le probl me communiquez avec le service la client le de Tripp Lite ATTENTION Ne d branchez pas votre syst me UPS pour tester ses batteries La mise la terre serait mise hors fonction et vos connexions r seau ne seraient plus prot g s contre les surtensions pr judiciables Suivant la condition de tension d arriv e la LED DETECTION DE TENSION D ENTR E BASSE HAUTE peut ou ne pas tre allum e Voyants lumineux Les descriptions des voyants lumineux ne sont applicables que si le syst me UPS est branch une prise de secteur et mis sous tension LINE POWER gt alimentation du secteur Ce voyant vert s allume tant VA que le syst me UPS re oit une alimentation lectrique normale du secteur Le voyant clignote si le syst me UPS est en mode CHARGE ONLY pour indi quer que ce syst me ne passera pas en mode d alimentation de secours en cas de panne de secteur ou de baisse de tension BATTERY POWER gt alimentation de batterie Ce voyant jaune s al lume si le syst me UPS alimente votre mat riel par batterie Exploitation de base suite LA YN BATTERY CHARGE recharge de la batterie Ce voyant rouge reste allum en continu apr s l ex cution d un autotest pour indiquer que la batterie du syst

Download Pdf Manuals

image

Related Search

Related Contents

Manual del propietario - Homocrisis by Toshiba Calefacción & Aire  Sony ICF-403L User's Manual  DeLOCK 82667 USB cable  ÀSIIBBIS Ieclmiques IIES 0llél`lllÎ0ll3 de “me  ACU-IDU-UM 9-1 - SatService GmbH  Attenzione - Viessmann  hosted CRM una solución que administra la relación con sus  Emerson LXP48F1 Power Supply User Manual  WV 45 Plus  PCU Manual PDF - Red Lion Controls  