1. PC www amp p c com Basic Rack Power Distribution Unit Installation This manual is available in English on the enclosed CD Dieses Handbuch ist in Deutsch auf der beiliegenden CD ROM verf gbar Este manual est disponible en espa ol en el CD ROM adjunto Ce manuel est disponible en fran ais sur le CD ROM ci inclus Questo manuale e disponibile in italiano nel CD ROM allegato amp vY aY VvoEBA amp MO CD ROM DETERINKT Instrukcja Obslugi w j zyku polskim jest dost pna na CD O manual em Portugu s est dispon vel no CD ROM em anexo Bu kullan m k lavuzunun Tiirk e si ilisikte g nderilen CD icerisinde mevcuttur Viucrpykius no UCHNOIP3OBANMIO NA PYCCKOM I3bIKe puJraraercs Ha gucke CD Contents Preliminary Informati0N Overview eieaa a Eia eee 1 Receiving soo fee aa Boer te ann e ee 1 Inventory iii ale te ae ea 1 Please recycle o o oooooomoommomo o 1 How to Install the Rack PDU Mounting options o o o oo 2 Toolless mounting o o oo 2 Bracket mounting 3 Warranty and Service LL Limited warranty o oooooooo o 4 Warranty limitations 4 Obtaining service o oooooooo o 4 Life Support Policy lt lt lt General policy oo oooooooo o 7 Examples of life support devices 7 Basic Rack Power Distribu
2. the rear panel of the enclosure 2 Snap the Rack PDU into place by pushing it downward until it locks into position You can mount two PDUS on one side of the enclosure by using the toolless mounting method Note 2 Basic Rack Power Distribution Unit How to Install the Rack PDU Bracket mounting To mount the Rack PDU vertically in a NetShelter or any standard EIA 310 D rack or enclosure 1 Attach the vertical mounting brackets to the Rack PDU using four 8 32 flat head screws per bracket A Use only supplied screws Caution eg 2 Attach the PDU to a vertical mounting rail in the rear of the enclosure using two additional screws per bracket not provided o00000000000000000000000000E Basic Rack Power Distribution Unit 3 Warranty and Service Limited warranty APC warrants the Basic Rack PDU to be free from defects in materials and workmanship for a period oftwo years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Warranty limitations Except as provided herein APC makes no warranties express or implied including warranties of merchantabilit
3. C the APC logo InfraStruXure and NetShelter are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 1917 001 10 2004
4. ny other organization Therefore these units do not meet the requirements for use in direct patient care www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information WWw apc com support Global support searching APC Knowledge Base and using e support Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure 1 877 537 0607 Customer Support Line toll free APC headquarters U S 1 800 800 4272 Canada toll free Latin America oon Baal Europe Middle East 353 91 702000 Africa Ireland Japan 0 35434 2021 Australia New Zealand 61 2 9955 9366 South Pacific area Australia Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2004 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited AP
5. tion Unit Preliminary Information Overview This booklet provides information for installing Basic Rack Power Distribution Units Rack PDUs Receiving Inspect the package and contents for shipping damage and make sure that all parts were sent Immediately report any shipping damage to the shipping agent Report missing contents product damage or other problems with the product to APC or your APC reseller Inventory Quantity Item 1 Basic Rack PDU 2 Vertical mounting brackets 870 8473 8 8 32 flat head screws Please recycle The shipping materials are recyclable Please save them for later use or dispose of them appropriately Basic Rack Power Distribution Unit How to Install the Rack PDU Mounting options You can install the Basic Rack PDU in one oftwo ways using toolless mounting pegs provided or the vertical mounting brackets provided To install the Basic Rack PDU using the toolless mounting method install it in the rear of the NetShelter VX Enclosure in the cable channel directly behind the rear vertical mounting rails To install the Basic Rack PDU using the mounting brackets install it on a vertical mounting rail in the rack or enclosure Toolless mounting In order to mount the Rack PDU using the toolless mounting option you must install it in a NetShelter VX Enclosure 1 Slide both mounting pegs into the holes located in the cable channel in
6. upport Policy General policy American Power Conversion APC does not recommend the use of any of its products in the following situations In life support applications where failure or malfunction ofthe APC product can be reasonably expected to cause failure ofthe life support device or to affect significantly its safety or effectiveness n direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances Examples of life support devices The term ife support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or a
7. y and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction Obtaining service To obtain support for problems with the Basic Rack PDU 1 Note the serial number and date of purchase The serial number is located on the bottom of the PDU 2 Contact Customer Support at a phone number on the back cover of this document A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a Return Material Authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number 4 Basic Rack Power Distribution Unit Life S