APC MASTERSWITCH POWER RECEPTACLE BAYING TRAY
Contents
1. warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary from state to state As a general policy APC does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness APC does not recommend the use of any of its products in direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances MasterSwitch Power Receptacles continued Examples of life support devices Additional safety warrnings The term ife supp
2. APC MasterSwitch Power Receptacles AP9510 Series Introduction Electrical information Mounting options APC MasterSwitch Power Receptacles increase the maxi mum amperage controlled by a MasterSwitch unit A North American model of MasterSwitch can supply a maximum of 12 amps total over eight outlets Using eight 5 15 Power Recepta cle units for example you can control power to a total load of up to 96 amps 12 amps per receptacle using a single MasterSwitch For international models you can control power to loads totaling 80 A 10 amps per receptacle using a single MasterSwitch unit You can mount up to three Power Receptacle units in a Power Receptacle Tray AP9510BAY which installs into an APC NetShelter enclosure You can mix and match various Power Receptacle models in the Power Receptacle Tray The tray requires 2U of space in the NetShelter and can fit conveniently on the rear mounting flanges behind a MasterSwitch unit APC Recep i Part Number tacle Volts Amps Relay Coil 5 15 100 120 VAC AP9510515 duplex 115 12 1 17 24 mA 5 20 100 120 VAC AP9510520 duplex 115 16 1 17 24 mA 100 120 VAC AP9510L620 L6 20 240 16 2 34 48 mA 100 120 VAC AP9510L630 L6 30 240 24 2 34 48 mA AP95103202 IEC320 240 10 1 200 240 VAC international Quad 8 5 10 mA Power Receptacles can be placed on a desk or mounted in a rack To place on a desk attach the four r
3. ard EIA 310 D 19 rack use the hardware provided with the Power Receptacle Tray and perform the following steps in the order given 1 Plan the mounting location for the tray and each unit within the tray The figure on page 4 shows the tray mounted at the rear of a NetShelter at the same height as the MasterSwitch which has been mounted on the front Consider your need for proximity to the UPS and to the attached load s Note You must install Power Receptacles near the attached load s so that the outlet is easily accessible MasterSwitch Power Receptacles continued Mounting power receptacles in a rack continued 2 Using a Phillips head screwdriver remove the four outermost 6 32 screws from the front panel of each Power Receptacle to be mounted in the tray as shown in the figure below Remove Screws Remove blanking panels from the front of the Power Receptacle Tray as necessary Insert each Power Receptacle unit into one of the bays of the tray aligning the holes on front panel of the unit with the holes in the flanges of the tray Attach with the four 6 32 screws removed in Step 2 Attach a blanking panel to any empty bays using four 6 32 screws provided See the figure on page 4 for an example setup Place the mounting brackets on the side of the tray inserting the two tray studs into the slit of each bracket Slide the brackets forward to allow room for the powe
4. ications 3 Connect the relay control input cord on the rear panel of the Power Receptacle to an outlet on the rear of the MasterSwitch Note To disconnect perform steps 1 3 in reverse order The following table provides Power Receptacle specifications not listed in Electrical information on page 1 AP95103202 Item Specification Approvals North American UL CSA AP9510515 AP9510520 AP9510L620 AP9510L630 International VDE CE Operating temperature 5 C to 45 C Operating humidity 35 to 85 non condensing MasterSwitch Power Receptacles continued Limited warranty Warranty limitations Life support policy American Power Conversion APC warrants the Power Receptacle to be free from defects in material and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchase Except as provided herein American Power Conversion makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied
5. mission is prohibited APC the APC logo MasterSwitch and NetShelter are trademarks of American Power Conversion Corporation and may be registerd in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 0322D 08 2001
6. n Zum Trennen der Stromversorgung zuerst das zweiadrige Steuerkabel entfernen und danach das dreiadrige Netzkabel Das Stromversorgungsmodul immer in normaler aufrechter Lage befestigen Espa ol e Siempre conecte el cable de suministro el ctrico principal de tres puntos antes de conectar el cable de control de dos puntos Al apagar el suministro el ctrico desconecte el cable de control de dos puntos antes de desconectar el cable de suministro de tres puntos e Siempre instale el m dulo de suministro el ctrico con el lado derecho hacia arriba MasterSwitch Power Receptacles continued Additional Italiano safety warrnings e Prima di collegare il cavo di controllo a due conduttori continued collegare sempre il cavo di alimentazione a tre conduttori Per interrompere l alimentazione staccare il cavo di controllo a due conduttori prima di scollegare il cavo di alimentazione a tre conduttori e Installare sempre il modulo di alimentazione con il lato destro rivolto verso l alto Portugu s e Ligue sempre o cabo principal de alimenta o de tr s fios antes de ligar o cabo de controlo de dois fios Ao desligar a corrente desligue o cabo de controlo de dois fios antes de desligar o cabo de alimenta o de tr s fios e Instale sempre o M dulo de Alimenta o com o lado direito virado para cima Entire contents copyright 2001 American Power Conversion All rights reserved Reproduction in whole or in part without per
7. ort device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults or infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with this modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care English e Always connect the three wire main power cord before connecting the two wire control cord When removing power disconnect the two wire control cord before disconnecting the three wire power cord e Always install the Power Receptacle right side up Fran ais e Toujours brancher le cordon lectrique trois fils avant de brancher le cordon de commande deux fils Pour couper le courant d brancher d abord le cordon deux fils avant de d brancher le cordon trois fils e Toujours installer le Module lectrique avec le c t droit vers le haut Deustch e Das dreiadrige Netzkabel immer vor dem zweiadrigen Steuerkabel anschlieBe
8. r cords that will be connected at the rear of the rack Attach using two 8 32 acorn nuts provided with the Power Receptacle Tray for each bracket MasterSwitch Power Receptacles continued Mounting power receptacles in a rack continued Connecting the power receptacles a 5 MasterSwitch Power Lo Module o Tray n IEE I a ERE TE O N O Mounting ra Bracket 60000090000 000000000 SS SSS SS SS SSS SSS SS 800000000480 000000000 NOccroorce rc pe EROE En ol ADONE CRE Da Cay eRe fa QNT oe 2 a i Acorn QI oO Nut Shi E fe 9 Blanking Je DI D f Panel g Power B g f I Modules DI Seal Dl Ael E Attach the tray assembly to the rack using hardware provided with the rack To connect the Power Receptacle s refer to the figure on page 5 and perform the following steps in the order given 1 Connect the power cord on the front panel of the Power Receptacle to your APC UPS or to a branch circuit capa ble of supplying power to the connected loads Note International models do not include a power cord You must supply your own However the procedure for connecting power is the same 2 Connect the load s to the outlet s on the front panel of the power receptacle MasterSwitch Power Receptacles continued Connecting the power receptacles continued Additional specif
9. ubber feet supplied to the bottom of the unit To mount in a rack use the Power Receptacle Tray AP9510BAY and follow the mounting instructions in Mounting power receptacles in a rack on page 2 MasterSwitch Power Receptacles continued Warnings AN Mounting power receptacles in a rack Exceeding the voltage or amperage limits for the individual Power Receptacles could cause fire damage or shock Do not exceed the load capacity of the UPS or branch circuit by connecting more than one fully loaded Power Receptacle To calculate the expected load consult the nameplate ratings of all connected equipment You must maintain reliable grounding of all equipment Pay particular attention to supply connections other than direct connections to the branch circuit Do not exceed the operating temperature or humidity limits shown in Additional specifications on page 5 Note that the ambient temperature in a rack environment may be greater than the ambient room temperature When installing the Power Receptacles in a rack Do not mount the receptacles in a location that impedes the flow of air in the rack Do not mount the receptacles in a way that loads the rack unevenly causing the rack to become unstable Disconnect the front panel power cord and the relay control input cord before moving the Power Receptacle Both cords carry hazardous voltages To mount Power Receptacles in a NetShelter enclosure or other stand