1. Installation with minimum configuration system based pricing U4827E Installation with HP provided configuration system based pricing U4831E ProCurve Switch 4108gl ProCurve Switch 4108gl Bundle and ProCurve Switch 4160g1 3 year 4 hour onsite 13x5 coverage for hardware H7675E 3 year 4 hour onsite 24x7 coverage for hardware H7676E e 3 year 4 hour onsite 24x7 coverage for hardware 24x7 software phone support U6320E Installation with minimum configuration system based pricing U4827E e Installation with HP provided configuration system based pricing U4831E Check www hp com go procurveservices for part numbers and service level descriptions For details about services and response times in your area please contact your local HP sales office ProCurve Switch 4100gl Series Specifications What s included Ports Maximum ports Physical characteristics Dimensions D x W x H Weight fully loaded Memory and processor Fabric processor type and speed Module processor type and speed Flash SRAM Packet buffer size SDRAM Mounting Performance Latency Throughput Switch fabric speed Routing table size Environment Operating temperature Operating relative humidity Non operating Storage temperature Non operating Storage relative humidity Altitude Electrical characteristics Maximum BTUs Voltage Current Power consumption Frequency Safety Emissions Im
2. ordered separately J4116A ProCurve Switch Gigabit Stacking Kit J4131B ProCurve Gigabit SX Transceiver J4132A ProCurve Gigabit LX Transceiver J4834A ProCurve 100 1000 T Transceiver J4853A ProCurve 100 FX SC Transceiver ProCurve Switch gl xI vl Redundant Power Supply J4839A not pictured Physical characteristics Dimensions D x W x H 20 07 x 16 0 x 12 7 cm 7 9 x 6 3 x 5 0 in Weight 2 5 kg 5 55 Ib Electrical characteristics Voltage 100 127 VAC 200 240 VAC Maximum current 8 2 A 3 8 A Frequency 50 60 Hz Notes For additional RPS specification information see the data sheet for the product in which the RPS is being installed bb a a a o o o o o rn ProCurve Switch gl 12 Port 100 FX MTRJ Module J4892A Ports 12 100Base FX ports IEEE 802 3u Type 100Base Fx Connector MTRJ Duplex half or full Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 65 kg 1 45 Ib Cabling Type 62 5 125 um or 50 125 um core cladding diameter graded index multimode fiber optic complying with ITU T G 651 and ISO IEC 793 2 Type A1b or Ata respectively Maximum distance 2 km full duplex or 412 m half duplex Additional accessories ProCurve Gigabit SX LC Mini GBIC J4858B ProCurve Gigabit LX LC Mini GBIC J4859B ProCurve Gigabit LH LC Mini GBIC J4860B ProCurve Gigabit 1000Base T Mini GBIC J8177B ProCurve Switch Gigabit Stacking Kit J4116A
3. 50 or 60 Hz IEC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 lt 10 2 us FIFO 64 byte packets Up to 35 7 million pps 18 3 Gbps 8 000 entries 0 C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz EN55024 CISPR 24 IEC 61000 4 2 4kV CD 8 kV AD IEC 61000 4 3 3V m IEC 61000 4 4 1 0 kV power line 0 5 kV signal line IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 6 3V IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 ProCurve Manager included ProCurve Manager Plus command line interface Web browser configuration menu out of band management serial RS 232C RFC 783 TFIP RFC 951 BootP RFC 1542 BootP RFC 854 Telnet RFC 768 UDP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 2030 Simple Network Time Protocol IEEE 802 3x Flow Control DHCP Relay RFC 2236 IGMP v1 v2 v3 IEEE 802 1D Spanning Tree IEEE 802 1w Rapid Convergence Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol RFC 1492 TACACS RFC 2138 RADIUS RFC 2866 RADIUS accounting SSHv1 SSHv2 Secure Shell Secure Sockets Layer SSL IEEE 802 1X Network Login I
4. ProCurve Gigabit SX Transceiver J4131B ProCurve Gigabit LX Transceiver J4132A ProCurve 100 1000 T Transceiver J4834A ProCurve 100 FX SC Transceiver J4853A Services for accessories are covered under the product in which they are installed
5. interruptions Harmonics Flicker Management Standards and protocols ProCurve Switch 4104gl J4887A N A 4 open module slots 1 RS 232C DB 9 console port Supports a maximum of 96 10 100 ports or 80 Gigabit ports plus 8 mini GBICs or 24 mini GBICs or a combination 38 86 x 44 2 x 13 34 cm 45 3 x 17 4 x 5 25 in 3U height 6 7 kg 14 75 lb Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB N A 512 KB 8 MB ProCurve Switch 4140gl J8151A 2 ProCurve Switch gl 20 Port 10 100 1000 Module J4908A 2 open module slots 40 10 100 1000 ports and 4 mini GBIC slots 1 RS 232C DB 9 console port Supports a maximum of 48 10 100 ports or 80 Gigabit ports plus 8 mini GBICs or 16 mini GBICs or a combination 38 86 x 44 2 x 13 34 cm 15 3 x 17 4 x 5 25 in 3U height 10 4 kg 22 9 Ib Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB N A 512 KB 8 MB ProCurve Switch 4148gl J4888A 2 ProCurve Switch gl 24 Port 10 100 TX Module J4862B 2 open module slots 48 10 100 ports 2 x J4862B 1 RS 232C DB 9 console port Supports a maximum of 96 10 100 ports or AO Gigabit ports plus 4 mini GBICs or 12 mini GBICs or a combination 38 86 x 44 2 x 13 34 cm 15 3 x 17 4 x 5 25 in 3U height 7 18 kg 15 84 Ib Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB N A 512 KB 8 MB Mounts in an ElA sta
6. 45 3 x 17 4 x 8 75 in 5U height 10 4 kg 22 9 Ib Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB 512 KB 1 MB N A Mounts in an ElA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only lt 10 2 us FIFO 64 byte packets Up to 71 4 million pps 36 6 Gbps 8 000 entries O C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz lt 10 2 us FIFO 64 byte packets Up to 71 4 million pps 36 6 Gbps 8 000 entries 0 C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz cUL CSA 950 EN 60950 IEC 60950 NOM 019 SCFI 1994 UL 1950 3rd edition EN55024 CISPR 24 EC 61000 4 2 4kV CD 8 kV AD EC 61000 4 4 1 0 kV power line 0 5 kV signal line EC 61000 4 5 1 kV 2 kV AC EC 61000 4 6 3V EC 61000 4 8 1A m 50 or 60 Hz EC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 FCC Class A EN55022 CISPR 22 Class A VCCI Class A EN55024 CISPR 24 IEC
7. 61000 4 2 4kV CD 8 kV AD IEC 61000 4 3 3V m IEC 61000 4 4 1 0 kV power line 0 5 kV signal line IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 6 3V IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 lt 10 2 us FIFO 64 byte packets Up to 71 4 million pps 36 6 Gbps 8 000 entries O C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz EN55024 CISPR 24 IEC 61000 4 2 4kV CD 8 kV AD IEC 61000 4 3 3V m IEC 61000 4 4 1 0 kV power line 0 5 kV signal line IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 6 3V IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 ProCurve Manager included ProCurve Manager Plus command line interface Web browser configuration menu out of band management serial RS 232C RFC 783 TFTP RFC 951 BootP RFC 1542 BootP RFC 854 Telnet RFC 768 UDP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 2030 Simple Network Time Protocol IEEE 802 3x Flow Control DHCP Relay RFC 2236 IGMP v1 v2 v3 IEEE 802 1D Spanning Tree IEEE 802 1w Rapid Convergence Spanning Tree IEEE 802 3a
8. EEE 802 1Q VLAN tagging IEEE 802 1Q GVRP IEEE 802 1p Priority SNMPv1 v2c v3 HTML and telnet management RFC 1493 Bridge MIB RFC 1213 MIB II RFC 2096 IP Forwarding Table MIB RFC 2737 Entity MIB RFC 2863 Evolution of Interface RFC 2665 Ethernet MIB RFC 2819 Four groups of RMON 1 statistics 2 history 3 alarm and 9 events RFC 2021 RMON probe configuration RMON v2 RFC 2668 IEEE 802 3 MAU MIB RFC 2613 SMON RFC 2674 IEEE 802 1p and IEEE 802 1Q Bridge MIB RFC 2618 RADIUS Client MIB RFC 2620 RADIUS Accounting MIB ProCurve Switch gl Modules and RPS ProCurve Switch gl 20 Port 10 100 1000 Module J4908A Ports 20 auto sensing 10 100 1000 ports IEEE 802 3 Type 10Base T IEEE 802 3u Type 100Base TX IEEE 802 3ab Type 1000Base T 2 open mini GBIC slots IEEE Auto MDIX yes Connector RJ 45 Duplex half or full Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 56 kg 1 25 Ib Mini GBICs supported ordered separately J4858B ProCurve Gigabit SX LC Mini GBIC J4859B ProCurve Gigabit LX LC Mini GBIC J4860B ProCurve Gigabit LH LC Mini GBIC J8177B ProCurve Gigabit 1000Base T Mini GBIC Other mini GBICs supported J4858A ProCurve Gigabit SX LC Mini GBIC J4859A ProCurve Gigabit LX LC Mini GBIC J4860A ProCurve Gigabit LH LC Mini GBIC Cabling Type 10Base T Category 3 or better 100 Q differential unshielded twisted pair UTP or shielded twis
9. ProCurve Switch 4100gl Series The ProCurve Switch 4100gl series is convergence ready and easy to use and is available in compact 8 slot and 4 slot modular form factors Based on ProCurve Fast Path Technology these switches provide reliable high performance high density 10 Mbit 100 Mbit or Gigabit connectivity for a growing network The ProCurve 4100gl series is the low cost modular alternative to stackable switches and includes a lifetime warranty _ N er ProCurve Switch 4108gl J4865A ProCurve Switch 41048 J4887A i a x k a a ProCurve Switch 4160gl J8152A ProCurve Switch 4140gl J8151A ProCurve Networking HP Innovation ProCurve Switch 4108g Bundle J4861A miisi ane aban ProCurve Switch 414881 J4888A ProCurve Switch 4100gl Series Features and benefits Performance Fast Path technology wire speed switching of intra module traffic for up to 31 9 million pps throughput fully loaded 8 slot chassis capable of switching 255 million pps e Fast switch fabric inter module traffic switching of up to 2 97 million pps Resiliency and high availability e IEEE 802 3ad Link Aggregation Control Protocol LACP and ProCurve trunking support up to 6 trunks each with up to 4 links ports per trunk trunking across modules is supported IEEE 802 1w Rapid Convergence Spanning Tree Protocol increases network uptime through faster recovery fr
10. al unshielded twisted pair UTP or shielded twisted pair STP complying with IEEE 802 3 Type LOBase T 100Base TX Category 5 or better 100 differential unshielded twisted pair UTP or shielded twisted pair STP complying with IEEE 802 3u 100Base TX Maximum distance 100 m gir re A ProCurve Switch gl 6 Port 100 1000 T Module J4863A Ports 6 auto sensing 100 1000 ports IEEE 802 3u Type 100Base TX IEEE 802 3ab Type 1000Base T EEE Auto MDIX yes Connector RJ 45 Duplex 100Base TX half or full 1000Base T full Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 45 kg 1 0 Ib Cabling ype 100Base TX Category 5 or better 100 differential unshielded twisted pair UTP or shielded twisted pair STP complying with IEEE 802 3u 100Base TX 1000Base T Category 5 5E or better recommended 100 Q differential 4 pair unshielded twisted pair UTP or shielded twisted pair STP balanced complying with IEEE 802 3ab 1000Base T Maximum distance 100 m Services for accessories are covered under the product in which they are installed ProCurve Switch gl Modules and RPS ba eee ui ed DE ko SASI I B ProCurve Switch gl Transceiver Module J4864A Ports 3 open transceiver slots Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 52 kg 1 16 Ib Transceivers supported
11. d Link Aggregation Control Protocol RFC 1492 TACACS RFC 2138 RADIUS RFC 2866 RADIUS accounting SSHv1 SSHv2 Secure Shell Secure Sockets Layer SSL IEEE 802 1X Network Login IEEE 802 1Q VLAN tagging IEEE 802 1Q GVRP IEEE 802 1p Priority SNMPv1 v2c v3 HTML and telnet management RFC 1493 Bridge MIB RFC 1213 MIB Il RFC 2096 IP Forwarding Table MIB RFC 2737 Entity MIB RFC 2863 Evolution of Interface RFC 2665 Ethernet MIB RFC 2819 Four groups of RMON 1 statistics 2 history 3 alarm and 9 events RFC 2021 RMON probe configuration RMON v2 RFC 2668 IEEE 802 3 MAU MIB RFC 2613 SMON RFC 2674 IEEE 802 1p and IEEE 802 1Q Bridge MIB RFC 2618 RADIUS Client MIB RFC 2620 RADIUS Accounting MIB ProCurve Switch 4100gl Series What s included Ports Maximum ports Physical characteristics Dimensions D x W x H Weight fully loaded Memory and processor Fabric processor type and speed Module processor type and speed Flash SRAM Packet buffer size SDRAM Mounting Performance Latency Throughput Switch fabric speed Routing table size Environment Operating temperature Operating relative humidity Non operating Storage temperature Non operating Storage relative humidity Altitude Electrical characteristics Maximum BTUs Voltage Current Power consumption Frequency Safety Emissions Immunity EN ESD Radiated EFT Burst Surge Conducted Power frequency magnetic field Voltage dips and
12. munity EN ESD Radiated EFT Burst Surge Conducted Power frequency magnetic field Voltage dips and interruptions Harmonics Flicker Management Standards and protocols ProCurve Switch 4108gl J4865A N A 8 open module slots 1 RS 232C DB 9 console port Supports a maximum of 192 10 100 ports or 160 Gigabit ports plus 16 mini GBICs or 48 mini GBICs or a combination 38 86 x 44 2 x 22 23 cm 45 3 x 17 4 x 8 75 in 5U height 9 4 kg 20 7 Ib Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB 512 KB 1 MB N A ProCurve Switch 4160gI J8152A 3 ProCurve Switch gl 20 Port 10 100 1000 Module J4908A 5 open module slots 60 10 100 1000 ports and 6 mini GBIC slots 1 RS 232C DB 9 console port Supports a maximum of 120 10 100 ports or 160 Gigabit ports plus 16 mini GBICs or 36 mini GBICs or a combination 38 86 x 44 2 x 22 23 cm 415 3 x 17 4 x 8 75 in 5U height 13 9 kg 30 6 Ib Motorola PowerPC 200 MHz 8 MB flash 32 MB SDRAM IDT MIPS32 125 MHz 512 KB 512 KB 1 MB N A ProCurve Switch 4108gl Bundle J4861A 3 ProCurve Switch gl 24 port 10 100 TX Module J4862B 1 ProCurve Switch gl Transceiver Module J4864A 4 open module slots 72 10 100 ports and 3 transceiver ports 1 RS 232C DB 9 console port Supports a maximum of 168 10 100 ports or 80 Gigabit ports plus 8 mini GBICs or 24 mini GBICs or a combination 38 86 x 44 2 x 22 23 cm
13. ndard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only lt 10 2 us FIFO 64 byte packets Up to 35 7 million pps 18 3 Gbps 8 000 entries 0 C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz lt 10 2 us FIFO 64 byte packets Up to 35 7 million pps 18 3 Gbps 8 000 entries O C to 55 C 32 F to 131 F 15 to 95 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 65 C 149 F non condensing Up to 4 6 km 15 091 ft 2 152 BTU hr 100 127 VAC 200 240 VAC 8 2 A 3 8 A 630 W 50 60 Hz cUL CSA 950 EN 60950 IEC 60950 NOM 019 SCFI 1994 UL 1950 3rd edition EN55024 CISPR 24 EC 61000 4 2 4kV CD 8 kV AD EC 61000 4 3 3V m EC 61000 4 4 1 0 kV power line 0 5 kV signal line EC 61000 4 5 1 kV 2 kV AC EC 61000 4 6 3V EC 61000 4 8 1A m 50 or 60 Hz EC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 FCC Class A EN55022 CISPR 22 Class A VCCI Class A EN55024 CISPR 24 IEC 61000 4 2 4kV CD 8 kV AD IEC 61000 4 3 3V m IEC 61000 4 4 1 0 kV power line 0 5 kV signal line IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 6 3V IEC 61000 4 8 1A m
14. om failed links Optional redundant power supply provides uninterrupted power allows hot swapping of one of the two power supplies when installed Hot swappable modules permit modules mini GBICs and one of the power supplies in a redundant power supply configuration to be added or swapped without interrupting the network Layer 3 routing e Basic IP routing enables automatic routing to the connected VLANs and up to 16 static routes including one default route in IP networks Layer 2 switching VLAN support and tagging support complete IEEE 802 10 4 096 VLAN IDs and 30 VLANs simultaneously e GARP VLAN Registration Protocol allows automatic learning and dynamic assignment of VLANs Security e Port security allows access only to specified MAC addresses which can be learned or specified by the administrator IEEE 802 1X and RADIUS network login and OpenVLAN control port based access for authentication and accountability TACACS eases switch management security administration by using a password authentication server Secure Shell SSHv2 encrypts all transmitted data for secure remote command line interface CLI access over IP networks Secure Sockets Layer SSL encrypts all HTTP traffic allowing secure access to the browser based management GUI in the switch Secure management access all access methods CLI GUI or MIB are securely encrypted through SSHv2 SSL and or SNMPv3 Quality of Se
15. rvice QoS Traffic prioritization IEEE 802 1p allows real time traffic classification into 8 priority levels mapped to 4 queues Manageability e RMON provides advanced monitoring and reporting capabilities for statistics history alarms and events Friendly port names allow assignment of descriptive names to ports ProCurve IEEE Auto MDIX automatically adjusts for straight through or crossover cables on all 10 100 1000 ports Dual flash images provide independent primary and secondary OS files for backup while upgrading Link Layer Discovery Protocol IEEE 802 1ab automated device discovery protocol for easy mapping by network management applications ProCurve Switch 4100gl Series Convergence e Stacking capability single IP address management for a virtual stack of up to 16 switches including the ProCurve 2500 series 2510 series 2600 series 2800 series 2810 series 2900 series 3400cl series 3500yl series 6108 6200yl 6400cl series 4200vl series and 4100g series Lifetime warranty for as long as you own the product with next business day advance replacement available in most countries Services ProCurve Switch 4104gl ProCurve Switch 4140g l and ProCurve Switch 4148 1 e 3 year 4 hour onsite 13x5 coverage for hardware U2855E e 3 year 4 hour onsite 24x7 coverage for hardware U2856E 3 year 4 hour onsite 24x7 coverage for hardware 24x7 software phone support U6304E
16. ted pair STP complying with IEEE 802 3 Type 10Base T 100Base TX Category 5 or better 100 Q differential unshielded twisted pair UTP or shielded twisted pair STP complying with IEEE 802 3u 100Base TX 1000Base T Category 5 5E or better recommended 100 Q differential 4 pair unshielded twisted pair UTP or shielded twisted pair STP balanced complying with IEEE 802 3ab 1000Base T Maximum distance 100 m m b A a a b a a 1 FLE LLELLE ProCurve Switch gl 6 Port Mini GBIC Module J4893A Ports 6 open mini GBIC slots Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 43 kg 0 96 Ib Mini GBICs supported ordered separately J4858B ProCurve Gigabit SX LC Mini GBIC J4859B ProCurve Gigabit LX LC Mini GBIC J4860B ProCurve Gigabit LH LC Mini GBIC J8177B ProCurve Gigabit 1000Base T Mini GBIC Other mini GBICs supported J4858A ProCurve Gigabit SX LC Mini GBIC J4859A ProCurve Gigabit LX LC Mini GBIC JA860A ProCurve Gigabit LH LC Mini GBIC ProCurve Switch gl 24 Port 10 100 TX Module J4862B Ports 24 auto sensing 10 100 ports IEEE 802 3 Type 10Base T IEEE 802 3u Type 100Base TX ProCurve Auto MDIX yes Connector RJ 45 Duplex half or full Physical characteristics Dimensions D x W x H 22 78 x 20 32 x 4 45 cm 8 97 x 8 0 x 1 75 in Weight 0 56 kg 1 24 Ib Cabling Type 10Base T Category 3 or better 100 Q differenti