Home
Sencor SCA BA02 alcohol tester
Contents
1. SCA BA02 User s manual Breathalyser Carefully read the entire user s manual before using the device and understand the safety measures and detailed operating instructions for the device Store the user s manual in a safe place for future reference If you sell the device do not forget to provide the user s manual to the new owner together with the device and its accessories Important safety measures IMPORTANT Using the breathalyser immediately after or within 15 minutes of consuming alcohol may damage the detection sensor and there is a danger of future measurements being inaccurate Unprofessional operation of this device is not covered by the warranty e Do not perform tests in strong winds or in a closed room which is filled with cigarette smoke or contains alcohol vapours e Ifthe flat batteries symbol appears on the display replace them with new ones Do not blow smoke food or liquids into the mouthpiece e Use the device only in an environment where temperatures are between 10 and 40 C Use in an environment outside this range may damage the device and may lead to incorrect test results e The level of alcoho in the breath depends on many factors that change over time The level can change already several minutes after the initial test e The measurement results of this device cannot be used as evidence in legal proceedings e The information obtained using this device is only informative in nature We recommend th
2. at it is not used for making decisions about the ability to perform any activity requiring responsibility Several factors e g natural gas remains smoke and undesirable breath may influence the level of the measured values Do not allow yourself or anybody else to drive a vehicle after consuming alcohol If you have consumed alcohol always organise for a designated driver or use an alternative form of transport e Neither the vendor nor the manufacturer are responsible for damages caused by the use of this device NEVER DRINK ALCOHOL IF YOU ARE PLANNING TO DRIVE A MOTOR VEHICLE Attention It is recommended to have the accuracy of the device tested after a year of use With more frequent use the lifetime of the device may be used up and the measurement results may not be accurate Description of the device Gas inlet LCD Indicator for READY Battery indicator ON OFF key No driving symbol BLOW LIGHT key START key Battery Installation 1 Remove the battery compartment cover 2 Insert 3 AAA alkaline batteries according to the polarity shown in the battery compartment 3 Return the cover back to its place 4 After inserting batteries the auto cleaning process will automatically commence The auto cleaning indicator will start to flash and the display will countdown the time 5 You will be able to use the device after the auto cleaning function is completed Note Remove the batteries if you
3. ay for about 9 seconds Then PH and Sta will intermittently appear on the display and the display will start the preheat countdown 4 Insert a straw or the blowing tube into the inlet opening above the LCD display Important Wait until the preheating process is completed because the sensor needs to heat up 5 READY will appear on the display as soon as the countdown is complete and a sound will be made The device is now ready for the test 6 Press and hold down the BLOW button The Blow indicator will light up on the display It is necessary blow into the tube at the same time The blowing into the tube must be constant and must last approximately 6 seconds until a sound is made and the measured value appears A measured value lower than 0 2 o will be displayed as LO low value A measured value between 0 2 o 1 5 o will appear on the display A measured value larger than 1 5 o will cause HI high value amp NO DRIVING Driving forbidden to appear on the display Warning signals Safe value A measured value lower than 0 2 o will be displayed as LO low value Low indicating value A measured value between a value gt 0 2 o and a warning value Warning level is shown on the display as a concentrated alcohol value Warning value The measured value equals or is greater than the warning concentrated value A sound signal will be made and NO DRIVING drivin
4. f you do not start the test within 8 seconds of the READY indicator appearing If you will not be using the device store it in a dry place If the low battery condition indicator light starts flashing the measurement is not accurate and it is necessary to replace the batteries without delay If the difference between two subsequent measurements is greater than 0 1 o you must repeat the measurement e To ensure that the measurement is accurate check that there are no alcohol remains in the device Wait until LOW is shown on the display Display this information by pressing the START button again Hold down BLOW and allow fresh air to be sucked into the opening If necessary you can remove alcohol remains by carefully shaking the device 0 5 0 0 05 Technical specifications Measuring range 0 2 1 5 o Battery 3 x 1 5V AAA alkaline batteries Display Digital LCD display with a two colour backlight Automatic shut off 2 minutes Duration of test 2 6 seconds Test preparation time 30 seconds Dimensions h x w x d 107 x 45 x25 mm Weight Approx 48 g without batteries Warning calibration value 0 2 0 3 0 5 0 8 o Accessories 3 blowing tubes The above stated data may be changed without giving reason Do not forget that the measured value may be affected by many factors such as gas pollution in the air smoke and various mouth odours Therefore consider the measured value only as info
5. g forbidden will start flashing on the screen for about 25 seconds The measured value will be shown and a message NO DRIVING driving forbidden will stay lit on the display If the measured value is greater than 1 5 o NO DRIVING Driving forbidden and HI high value will appear on the display Press the MODE button to cancel the sound signal IT IS FORBIDDEN TO DRIVE if the low warning value is exceeded Important notices e To ensure accurate measurement results it is necessary to perform so called auto cleaning if you have not used the device for longer than 2 weeks especially before first use Start the auto cleaning process by removing the batteries and rein serting them and turning on the device The indicator AUTO CLEANING will start to flash The auto cleaning process takes approximately 5 minutes and there will be a countdown on the display during this time In the last minute of the auto cleaning a sound will be made The device will automatically turns itself off after 1 minute and the auto cleaning process will be completed Check that no residual alcohol has remained inside the device before performing a test Pressing the ON OFF button will end the automatic cleaning process After 4 repeated tests let the device rest for 2 minutes If the message Err flashes on the display for longer than 5 seconds it may indicate incorrect handling You did not press and hold the BLOW button during the test I
6. ies in European Union states If you want to dispose of electric or electronic devices ask your retailer or supplier for the necessary information Disposal in other countries outside the European Union This symbol is valid in the European Union If you wish to discard this product ask your local authorities or retailer about proper disposal This appliance meets all the basic requirements of EU directives that apply to it Changes in the text design and technical specifications may change without prior notice and we reserve the right to make these changes Copyright 2012 Fast R a s Revision 05 2012
7. rmative in nature Neither the manufacturer nor the vendor take any responsibility arising from the use of this device Caution Using the breathalyser immediately after or within 15 minutes of consuming alcoholic beverages may damage the detection sensor there is a danger of future measurements being inaccurate Unprofessional operation of this device is not covered by the warranty Disposal of used batteries Take used batteries to designated collection points Follow the regulation in force in your country INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS Take the packaging material to a designated municipal waste facility DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT This symbol on products or original documents means that used electric or electronic products must not be added to ordinary municipal waste For proper disposal and recycling take these products to designated collection points Or as an alternative in some European Union states or other European countries you may return your appliances to the local retailer when buying an equivalent new appliance Correct disposal of this product helps save valuable natural resources and prevents damage to the environment caused by improper waste disposal Ask your local authorities or collection facility for more details In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste For business entit
8. will be storing the device or not using it for an extended period of time Batteries must not be exposed to excessive heat such as sunlight fire etc The incorrect use of batteries may lead to a electrolyte leak and corrosion To ensure that the device works correctly proceed according to the instructions below Do not insert the batteries in the wrong direction Do not charge heat open or short the batteries Do not throw batteries into a fire Do not leave discharged batteries in the device Do not combine various types of batteries or new and old batteries If you will not be using the device for a longer period of time remove the batteries to prevent potential damage caused by a subsequent battery leakage If the device is not working correctly or its efficiency is reduced change all batteries for new ones If electrolyte leaks out from the batteries have the device cleaned by an authorised service centre Application di After inserting the batteries the indicator AUTO CLEANING automatic cleaning will appear and the countdown of the automatic cleaning time will start Pressing the ON OFF button will interrupt the automatic cleaning process 2 Itis important to rinse your mouth with clean water before use Do not smoke or drink alcoholic beverages for at least 5 minutes before use 3 Press the START button for a short time to turn on the device The preheat sensor will be activated WAIT will flash on the displ
Download Pdf Manuals
Related Search
Related Contents
BENDIX BW7273 User's Manual Audio Breath Pacer Software User Guide gestão de conhecimento e comunidades de prática manual de instruções e operação Introduction - Multimedia Photo Panasonic NN-S553 1350 Watts Microwave Oven Mode d`emploi - Birchmeier Sprühtechnik AG Urgent Field Safety Notice テスタを用いた微分方程式の実験 SÈCHE-LINGE Copyright © All rights reserved.