Home
Fibaro FGFS-101
Contents
1. 12 24 VDC ADAPTER Fig 2 Connection to a constant power source Fig 3 Flood sensor s contacts extended with a wire Fig 4 Probes marking Vil OPERATING THROUGH THE Z WAVE NETWORK Fibaro Flood Sensor has two sensors built in flood and temperature sensors meaning it s a multichannel device In the Z Wave network s main controller the Sensor will be shown as two devices Flood Sensor Flood Sensor Temp XX Fig 5 Flood Sensor icon in HOME CENTER 2 VIII ASSOCIATIONS Through an association Fibaro Flood Sensor may control another Z Wave network device e g a Dimmer Relay Switch Roller Shutter RGBW Controller Wall Plug or a scene scene only through the Home Center 2 main controller NOTE Association allows for direct communication between Z Wave network devices Main controller does not take part in such 1 communication Using this mechanism Fibaro Flood Sensor may communicate with other devices even when the main controller is damaged e g in a fire Fibaro Flood Sensor allows for the associations of three groups 1 st Association Group is assigned to the device status sending the BASIC SET default or ALARM control frame to the associated devices 2 nd Association Group is assigned to a TMP button and tilt sensor ALARM GENERIC control frame will be sent to the associated devices in case a TMP butt
2. z a OPERATING MANUAL FLOOD SENSOR FGFS 101 EN A v1 00 Fibaro Flood Sensor is a universal Z Wave compatible flood and temperature sensor Device can be battery ca 2 years battery life or VDC powered 12 or 24 VDC Flood alarm is sent to the Z Wave network devices or additionally to any alarm system controller through opening a NC contact The device has built in temperature sensor monitoring temperature of e g floor Fibaro Flood Sensor is designed to be placed on the floor or on a wall with a flood sensor probe extended by connected wire The device has built in LED indicator and acoustic alarm In addition the sensor is equipped with a tilt sensor reporting tilt or movement to the main controller e g when someone has taken the Sensor from its original location LED diode signals flood operating mode or the Z Wave network communication range Fibaro Flood Sensor is sink proof which means it drifts on the water surface and keeps on sending alarm signal in case of substantial inundation of water SPECIFICATIONS Power Supply 12 24 VDC Battery Type CR123A Power Consumption at VDC operation 0 4W Output terminals maximum current 25mA carrying capacity ALARM NC TAMP NC Maximum voltage at output terminals 24V DC 20V AC EU standards compliance EMC 2004 108 EC R amp TTE 1999 5 WE Radio protocol Z Wave Radio frequency 868 4 MHz EU 908 4 MHz US 921 4 MHz ANZ 869 2 MHz RU Range up to 50m
3. 7 When the guarantee claim form is submitted correctly a representative of the Authorised Guarantee Service hereinafter as AGS shall contact the Customer 8 Defects revealed within the guarantee period shall be removed not later than 30 days from the date of delivering the Device to AGS The guarantee period shall be extended by the time in which the Device was kept by AGS 9 The faulty device shall be provided by the Customer with complete standard equipment and documents proving its purchase 10 Parts replaced under the guarantee are the property of the Manufacturer The guarantee for all parts replaced in the guarantee process shall be equal to the guarantee period of the original device The guarantee period of the replaced part shall not be extended 11 Costs of delivering the faulty device shall be borne by the Customer For unjustified service calls the Service may charge the Customer with travel expenses and handling costs related to the case 12 AGS shall not accept a complaint claim only when the Device was misused or the manual was not observed the Device was provided by the Customer incomplete without accessories or nameplate it was determined that the fault was caused by other reasons than a material or manufacturing defect of the Device the guarantee document is not valid or there is no proof of purchase 13 The Manufacturer shall not be liable for damages to property caused by defective device
4. The Manufacturer shall not be liable for indirect incidental special consequen tial or punitive damages or for any damages including inter alia loss of profits savings data loss of benefits claims by third parties and any property damage or personal injuries arising from or related to the use of the Device 14 The guarantee shall not cover mechanical damages cracks fractures cuts abrasions physical deformations caused by impact falling or dropping the device or other object improper use or not observing the operating manual damages resulting from external causes e g flood storm fire lightning natural disasters earthquakes war civil disturbance force majeure unforeseen accidents theft water damage liquid leakage battery spill weather conditions sunlight sand moisture high or low temperature air pollution damages caused by malfunctioning software attack of a computer virus or by failure to update the software as recommended by the Manufacturer damages resulting from surges in the power and or telecommunication network improper connection to the grid in a manner inconsistent with the operating manual or from connecting other devices not recommended by the Manufacturer damages caused by operating or storing the device in extremely adverse conditions i e high humidity dust too low freezing or too high ambient temperature Detailed permissible conditions for operating the Device are def
5. see main controllers operating manual 2 Set the main controller into the learning mode 3 Triple click TMP button 4 Fibaro Flood Sensor will be detected and included Ill Z WAVE NETWORK EXCLUSION Complete the following steps to exclude a Fibaro Flood Sensor from the Z Wave network 1 Remove sensor s cover 2 Make sure sensor is connected to a battery or a DC power supply 3 Set a main controller into learning mode see main controllers operating manual 4 Triple click TMP button located inside Flood Sensor s casing IV SENSOR S INSTALLATION 1 Remove top cover 2 Include into the Z Wave network see pt II 3 Place sensor onto a surface prone to flooding All three electrodes underneath the device should evenly touch the surface 4 If the sensor is to be DC powered drill holes in it s casing and connect wires observing the wiring diagram no 2 5 Close sensor s casing NOTE After completing installation it s recommended to test sensor s operation by placing the entire sensor or it s probes extension wire onto water surface NOTE The Sensor detects resistance under 4MOhm between electrodes 1 and 3 1 and 2 according to scheme no 4 and electrodes connected to contacts SENS1 and SENS2 e NOTE 1 Contacts SENS1 and SENS2 are dedicated to flood detection only Do not connect external voltage NOTE When changing the Sensor s location it s recommended to wake up the de
6. the location of its individual components is automatically updated in real time through status confirmation signals received from devices operating in a mesh network Il Z WAVE NETWORK INCLUSION Use TMP button to include the Fibaro Flood Sensor into the Z Wave network In addition the device may be included into the Z Wave network in auto inclusion mode at connecting a DC power source mode active only after the built in battery has been disconnected Including the Fibaro Flood Sensor using auto inclusion mode 1 Make sure a DC power source is disconnected and the sensor is located within direct communication with the main controller s range The battery must be removed 2 Open the cover 3 Set the main controller into the learning mode see a main controller s operating manual 4 Connect a DC power source to include the Fibaro Flood Sensor into the Z Wave network in autoinclusion mode 5 Fibaro Flood Sensor will be detected and included NOTE e In case the Sensor is not detected proceed to the manual 1 inclusion described below or reset the Sensor and repeat auto inclusion procedure To deactivate auto inclusion mode press TMP button once after the Fibaro Flood Sensor has been connected to a DC power supply Manual Z Wave network inclusion 1 Connect a DC power supply to the Fibaro Flood Sensor or insert a battery Make sure the sensor is located within the Z Wave network s main controller s range
7. sent to 2 nd Association Group activation MOVEMENT_TAMPER BUTTON_TAMPER 1 byte Available settings 0 tamper alarms inactive 1 button tamper alarm active 2 movement tamper alarm active 3 button and movement tampers alarm active Default setting 2 Parameter size 1 byte The device is able to turn on alarms resulting from sensor s vibrations e g when the sensor is moved or the TMP button released 2 nd Association Group alarms are not cancelled 75 Visual and audible alarms duration The user can silence the Flood Sensor Because the Sensor s alarm may last for a long time it s possible to turn off visual and audible alarm signaling to save battery Available settings 0 65535 each 1 second Default setting 0 Parameter size 2 bytes The parameter determines a time period after which alarm will become quiet still active but the device will go into battery saving mode Visual or acoustic alarm will be reactivated after time period specified in the Parameter 76 When alarm status ceases alarm will be turned off immediately The value of 0 means visual and acoustic alarms are active indefinitely In battery power mode the Sensor will never go to sleep which may shorten battery life significantly NOTE s The main controller does not interpret negative numbers as 1 decimals That s why read value may be different than entered Negative numbers are coded in U2 standard Decimal Hex
8. adecimal U2 Value in main controller 32767 0x7FFF 32767 1 0x0001 1 0 0x0000 0 1 OxFFFF 65535 10000 OxD8FO 55536 32768 0x8000 32768 61 Low temperature alarm indicator colour Parameter stores RGB colour value Available settings 0 16777215 Default setting 255 blue 0x000000FF Parameter size 4 bytes e NOTE 1 A main controller interprets colours as a sum of it component colours value Each colours value is a number from 0 to 255 Example Indicated colour 65536 RED value 256 GREEN value BLUE value 62 High temperature alarm indicator colour Parameter stores RGB colour value Available settings 0 16777215 Default setting 16711680 red 0x00FF0000 Parameter size 4 bytes a NOTE A main controller interprets colours as a sum of it component 1 colours value Each colours value is a number from 0 to 255 Example Indicated colour 65536 RED value 256 GREEN value BLUE value Ld NOTE 1 The parameter is ignored when Parameter 2 is set to 0 76 Alarm frame Basic Set frame retransmission time when retaining flood alarm Parameter determines a time period after which an alarm frame will be retransmit ted The value of 0 cancels an alarm frame retransmission Available settings 0 65535 each 1 second Default setting 0 Parameter size 2 bytes NOTE bed In case a time period set in this parameter is shorter than the one 1 specified in parameter 75 th
9. ate i e 30 9 Alarm cancelling or turning a device off Basic command frame deactivation Allows for deactivating device turn off and alarm cancellation functions for the devices assigned to 1 st association group 1 byte Setting the parameter s value to 0 results in stopping BASIC SET 0 or ALARM WATER 0 control frames from being sent After sending flood alarm report the device will keep on reporting flooding after the flooding itself has ceased Such a state can be cancelled by choosing alarm cancelation from the MENU marked with green LED colour Available settings 0 alarm flooding cancellation inactive 1 alarm flooding cancellation active Default setting 1 Parameter size 1 byte 10 Temperature measurement interval Time interval in seconds between consecutive temperature measurements done by built in temperature sensor New temperature value is reported to the main controller if it differs from the previously measured by hysteresis defined in parameter 12 Available settings 1 65535 in seconds Default setting 300 5 minutes Parameter size 2 bytes The parameter determines time interval in seconds at which a Flood Sensor measures and reports ambient temperature and battery level If a temperature value will differ from previously reported by a value determined in parameter 12 e g P12 50 i e temperatures differ by 0 50C new temperature value will be reported If a battery level chang
10. d 62 settings 4 Currently chosen MENU position is signaled with an illumination colour Press and hold the TMP button for at least 3 seconds to enter MENU Inside MENU each of the positions will be signaled by another LED colour WHITE entering MENU confirmation GREEN cancel alarm for associated devices PINK Z Wave network s range test YELLOW sensor reset X CANCEL ALARM FOR ASSOCIATED DEVICES It s possible to cancel alarm for associated devices simply by entering MENU signaled by GREEN illumination XI Z WAVE RANGE TEST Fibaro Flood Sensor has a built in the Z Wave network main controller s range tester Follow the following instructions to test the main controller s range 1 Press and hold a TMP button for 10 15 seconds until a LED indicator colour changes to violet 2 Release the TMP button 3 Click the TMP button 4 LED indicator will signal the Z Wave network range see description below 5 To exit the Range Tester click the TMP button Z Wave Range Tester signaling modes LED Indicator pulsing green Fibaro Flood Sensor attempts to directly communicate with the main controller If the direct communication attempt fails the sensor will try routed communication through other devices which will be signaled with LED Indicator blinking yellow LED Indicator glowing green Fibaro Flood Sensor directly communicating with the main controller LED Indicator pulsing yellow Fibaro Flood Sen
11. e and should be compatible with such devices produced 1 by other manufacturers Any device compatible with Z Wave may be added to Fibaro system FIBARGROUP FIBARO In case of any technical questions contact customer service centre in your country www fibargroup com
12. e device will not quiet the alarm it will remain active 77 Flood sensor functionality turned off Allows for turning of the internal flood sensor Tamper and built in temperature sensor will remain active Available settings 0 Default flood sensor operation flood detection reactions 1 Built in flood sensor TURNED OFF doesn t change its state in the main controller doesn t send Alarms and Basic Set frames with flood state changes Always visible in the main controller as turned off Default setting 0 Parameter size 1 byte XV GUARANTEE 1 The Guarantee is provided by FIBAR GROUP Sp z o o hereinafter Manufacturer based in Poznan ul Lotnicza 1 60 421 Poznan entered in the register of the National Court Register kept by the District Court in Poznan VIII Economic Department of the National Court Register no 370151 NIP 7811858097 REGON 301595664 2 The Manufacturer is responsible for equipment malfunction resulting from physical defects manufacturing or material of the Device for 12 months from the date of its purchasing 3 During the Guarantee period the Manufacturer shall remove any defects free of charge by repairing or replacing at the sole discretion of the Manufacturer any defective components of the Device with new or regenerated components that are free of defects When the repair impossible the Manufacturer reserves the right to replace the device with a new or regenerated one
13. es the device will report a battery status change Battery Report The parameter is relevant when using a Flood Sensor in a battery power mode longer time interval means less frequent communication resulting in extended battery life After consecutive FAILED and SUCCESSFUL communication attempts the Sensor will go to standby mode 12 Temperature measurement hysteresis Determines a minimum temperature change value insensitivity level resulting in a temperature report being sent to the main controller according to the Parameter 10 settings Available settings 1 1 000 each 0 010C Default setting 50 0 5 C Parameter size 2 bytes 13 Alarm BROADCAST Value other than 0 means alarms are sent in BROADCAST mode with a priority over other communicates to all devices within the Fibaro Flood Sensor s range Available settings 0 broadcasts inactive 1 flood 1 st Association Group broadcast active tamper 2 nd Association Group broadcast inactive 2 flood broadcast inactive tamper broadcast active 3 flood broadcast active tamper broadcast active Default setting 0 Parameter size 1 byte 50 Low temperature alarm threshold Available settings 10 000 to 10 000 each 0 01 C Default setting 1 500 15 00 C Parameter size 2 bytes The parameter stores a temperature value below which LED indicator blinks with a colour determined by a Parameter 61 settings By default the LED indicator blin
14. extreme cases it fails to transfer required data The advantage of Fibaro System is that its devices apart from being transmitters and signal receivers also duplicate signal When a direct connection path between the transmitter and the receiver cannot be established the connection may be achieved through other intermediate devices Fibaro is a bi directional wireless system This means that the signal is not only sent to the receivers but also the receivers send the confirmation of its reception This operation confirms their status which checks whether they are active or not Safety of the Fibaro System transmission is comparable to the safety of transmission in data bus wired systems Fibaro operates in the free bandwidth for data transmission The frequency depends on radio regulations in individual countries Each Fibaro network has its own unique network identification number home ID which is why it is possible to co operate two or more independent systems in a single building without any interference Although Z Wave is quite a new technology it has already become recognized and officially a binding standard similarly to Wi Fi Many manufacturers in various industries offer solutions based on Z Wave technology guaranteeing their compatibility This means that the system is open and it may be extended in the future Find more information at www fibaro com Fibaro generates a dynamic network structure After Fibaro System is switched on
15. ined in the operating manual damages caused by using accessories not recommended by the Manufacturer damages caused by faulty electrical installation of the Customer including the use of incorrect fuses damages caused by Customer s failure to provide maintenance and servicing activities defined in the operating manual damages resulting from the use of spurious spare parts or accessories improper for given model repairing and introducing alterations by unauthorized persons defects caused by operating faulty Device or accessories 15 The scope of the guarantee repairs shall not include periodic maintenance and inspections in particular cleaning adjustments operational checks correction of errors or parameter programming and other activities that should be performed by the user Buyer The guarantee shall not cover natural wear and tear of the Device and its components listed in the operating manual and in technical documentation as such elements have a defined operational life 16 If a defect is not covered by the guarantee the Manufacturer reserves the right to remove such defect at its sole discretion repairing the damaged or destroyed parts or providing components necessary for repair or replacement 17 This guarantee shall not exclude limit or suspend the Customer rights when the provided product is inconsistent with the purchase agreement This Device may be used with all devices certified with Z Wave certificat
16. ks blue 51 High temperature alarm threshold Available settings 10 000 to 10 000 each 0 01 C Default setting 3 500 35 C Parameter size 2 bytes The parameter stores a temperature value above which LED indicator blinks with a colour determined by the Parameter 62 settings By default the LED indicator blinks red Colour Decimal value Red 16711680 Green 65280 Blue 255 Yellow 16776960 Turquoise 65535 Orange 16750848 White 16777215 LED indicator turned off 0 63 Managing a LED indicator under standard operation Parameter determines LED indicator s operation Set to 0 turns the indicator off saving a battery life Available settings 0 LED indicator doesn t indicate the temperature 1 LED indicator indicates the temperature blink every Temperature Measurement Interval Parameter 10 constant current and battery or Wake Up Interval battery mode 2 LED indicator indicates the temperature continuously only in constant power mode Default setting 2 Parameter size 1 byte 73 Temperature measurement compensation Available settings 10 000 to 10 000 Default setting 0 0 000C Parameter size 2 bytes Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level 74 Alarm frame
17. o 3 are not included in the package Choose a screw type depending on the building material it is being attached to DIAGRAMS DESCRIPTION 12V 12 24 VDC positive terminal GND negative ground terminal ALARM NC potential free flood sensor terminals for wired systems TAMP NC potential free tamper terminals for wired systems SENS1 SENS2 flood sensor electrodes terminals e NOTE 1 ALARM NC and TAMP NC connectors may be used as EOL protective loop s terminals VI FIBARO FLOOD SENSOR RESET Reset procedure deletes EPROM s memory including all information on the Z Wave network and the main controller Fibaro Flood Sensor s reset procedure 1 Make sure the Sensor is powered 2 Press and hold a TMP button for 15 20 seconds LED indicator glows yellow to confirm entering 4th sub menu 3 Release the TMP button 4 Click the TMP button once The LED indicator glowing red and then turning off will confirm a successful reset Reset completion will be confirmed by an acousic signal same as at the power source connection NOTE bss Reset procedure doesn t remove the Sensor from the Z Wave 1 network s main controller memory Prior to reset a sensor must be deleted from the Z Wave network ALARM SYSTEM HUB AUX COM Z1 Z2 Fig 1 Connection with alarm system TMP
18. on is released or a tilt sensor triggered depending on parameter 74 settings 3 rd Association Group reports the device status and allows for assigning single device only the main controller by default the device reports its status to the main controller Fibaro Flood Sensor allows for controlling 5 regular and 5 multichannel devices per an association group out of which 1 field is reserved for the Z Wave network main controller To add an association using Home Center 2 interface go to device settings and click the following icon a Select the device options tab Then specify to which group and what devices are to be associated Sending relevant information to devices that have been added to association groups may take even a few hours depending on configuration parameters settings IX LED VISUAL SIGNALS AND SETTINGS Fibaro Flood Sensor is equipped with a LED diode signaling sensor s operating modes and alarms In addition the LED indicator may inform of the Z Wave network range and the current temperature LED indicator signaling modes 1 Flood alarm is signaled with alternating white and blue light 2 In battery powering mode with parameter no 63 set to 1 LED indicator will periodically show temperature readouts depending on parameters 50 51 61 and 62 settings 3 In constant powering mode the current temperature readouts will be continuously signaled with a colour depending on the parameters 50 51 61 an
19. outdoors up to 30m indoors Depending on terrain and building structure Operational Temperature 0 40 C Measured temperature range 20 to 100 C Temperature measuring accuracy 0 5 C within 0 40 C range Dimensions Diameter x Height 72 x 28mm Operational temperature in VDC powering mode 20 C 70 C TECHNICAL INFORMATION Compatible with any Z Wave network controller May be connected to any alarm system potential free output terminal Extremely easy installation simply put on a surface prone to flooding May be installed anywhere flood sensor s contacts extended with a wire Battery or VDC powered When connected to an external VDC power source the battery serves as an emergency power source Theft protection tilt is reported to the Z Wave network or alarm system s main controller Two operating modes flood temperature sensor or just a temperature sensor NOTE e Connect while observing wiring diagram shown in this manual 1 only Incorrect wiring may be dangerous or result in the device breakdown Il GENERAL INFORMATION ABOUT FIBARO SYSTEM Fibaro is a wireless system based on Z Wave technology Fibaro provides many advantages when compared to similar systems In general radio systems create a direct connection between the receiver and transmitter However the radio signal is weakened by various obstacles located in its path apartment walls furniture etc and in
20. setting 4 000 each 66 minutes Defines a time period in seconds by which a Flood Sensor will perform a Wake up instruction communicate with main controller update parameters update software Flood Sensor will wake up each defined time interval and will always attempt to connect with the main controller without retrying if connection fails thus preventing a battery from discharging when the Sensor is used at the range limit in case of the main controller s breakdown or in case the sensor is taken away from the main controllers range This parameter is relevant in case of battery operation higher Wake up interval means the Sensor communicates less often saving a battery After successful communication attempt a sensor will go into standby mode update parameters or will enter a software update mode After failed communication attempt a sensor will go into standby mode until another time interval will have elapsed 1 Alarm cancellation delay Delays flood alarm cancelation for the device after flooding has ceased Available settings 0 3 600 in seconds each 1s Default setting 0 no delay immediate alarm cancelation Parameter size 2 bytes Determines time period in seconds by which a Flood Sensor will retain the flood state after the flooding itself has ceased Sensor will keep on reporting flooding to the main controller This parameter settings do not affect acoustic and visual alarms which turn off immedia
21. sor tries to establish routed connection with the main controller through intermediary devices LED Indicator glowing yellow Fibaro Flood Sensor communicates with the main controller through other intermediary devices After two seconds the Sensor will retry to directly connect to the main controller which will be signaled with the Indicator pulsing green LED Indicator pulsing violet Fibaro Flood Sensor communicates at the range limit If connection proves successful it will be confirmed with a yellow glow It s not recommended to use the sensor at the range limit LED Indicator glowing red Fibaro Flood Sensor unable to connect to the main controller directly or through another Z Wave network nodes XII SENSOR OPERATION WARNING By default flood sensor s insensitivity is set to 1 second which means flooding will be reported one second after it s been detected Tilt tamper is insensitive to little vibrations and turns After its activation insensitivity is turned off for 15 seconds After that each Sensor s movement will trigger audible alarm consisting of 3 brief acoustic signals XIII BATTERY USE WARNING Fibaro Flood Sensor is a battery powered device Using batteries other than specified may result in explosion Dispose of properly observing environmental protection rules XIV ADVANCED CONFIGURATION Wake up interval battery mode Available settings 0 or 5 86399 in seconds 5 s to 24 hours Default
22. tant powering mode a sensor may operate without a battery Installing a battery is recommended though as it will serve as an emergency power source When constant power fails sensor will automatically shift to an emergency mode All reports including flood and temperature will be sent immediately but it will not be possible to modify the configuration or association settings until constant power returns If a sensor served as a signal repeater for other Z Wave devices in emergency mode signal repeating function will be deactivated NOTE Fibaro Flood Sensor will automatically exit emergency mode once 12 24 VDC at 12 and GND terminals is detected according to diagram no 2 and the device wakes up after detecting an event i e flood alarm temperature report tilt or manual wake up using TMP button BATTERY TIPS Fibaro Flood Sensor s battery life is ca 2 years at factory default settings The current battery level is displayed in a Home Center 2 interface Red battery icon means a battery needs replacement In order to avoid triggering tamper alarm while replacing the battery Il nd association group s associations must be deleted and 1 Sensor s parameters configuration set to default Alternatively the Sensor may be powered by VDC power source 12 24 VDC in accordance with a wiring diagram no 2 in such a configuration a battery will serve as an emergency power supply NOTE Mounting screws shown in a diagram n
23. tely after flooding ceases 2 Acoustic and visual signals On Off in case of flooding The parameter allows for LED indicator and acoustic alarm deactivation in case of flooding detection Available settings 0 acoustic and visual alarms inactive 1 acoustic alarm inactive visual alarm active 2 acoustic alarm active visual alarm inactive 3 acoustic and visual alarms active Default setting 3 Parameter size 1 byte Changes in this parameter settings allow for increasing a battery life Settings changes will not affect the Sensors communication with the main controller commands to association groups alarms and reports will still be sent 5 Type of alarm frame sent to 1 st association group FLOOD Available settings 0 ALARM WATER command frame 255 BASIC SET command frame Default setting 255 Parameter size 1 byte The parameter determines a type of command frame sent by the Sensor in case flooding has been detected or cancelled 7 Forced dimming level roller blind opening level when sending turn on open command to 1 st association group devices In case of alarm frames alarm priority is determined Available settings 1 99 or 255 Default setting 255 Parameter size 1 byte The value of 255 allows for turning a device on In case of a Dimmer it means turning it on with the last memorized state e g Dimmer set to 30 and turned off turned on again using 255 command is turned on with last st
24. vice and reconfigure the Z Wave network by triple clicking the TMP button NOTE The TMP button has two functions 1 Including Excluding the device into from the Z Wave network 1 2 Tamper contact for Il nd Association Group When a sensor is included into the Z Wave network case opening alarm may be activated according to parameter 74 settings V POWERING MODE INFORMATION There are two powering modes for the Fibaro Flood Sensor By default it s powered by a factory included battery In addition it can work with a constant current after connecting a 12 24 VDC power supply to 12 and GND terminals see diagram no 2 Powering mode configuration is carried out automatically while a sensor is being included into the Z Wave network When battery powered a Fibaro Flood Sensor communicates with a Z Wave network main controller periodically Detected alarms are sent immediately but configuration parameters and associations settings only at specified wake up intervals or at a manual wake up TMP triple click In DC powering mode configuration and associations parameters are sent when necessary and in addition a sensor serves as a Z Wave signal repeater Switching to a constant current powering mode 1 Exclude a sensor from the Z Wave network 2 Connect constant current power source 12 24 VDC to 12 and GND terminals observing wiring diagram no 2 3 Include the Fibaro Flood Sensor into the Z Wave network In cons
25. which shall be free of any defects and its condition shall not be worse than the original device owned by the Customer 4 In special cases when the device cannot be replaced with the device of the same type e g the device is no longer available in the commercial offer the Manufacturer may replace it with a different device having technical parameters similar to the faulty one Such activity shall be considered as fulfilling the obligations of the Manufacturer The Manufacturer shall not refund money paid for the device 5 The holder of a valid guarantee shall submit a guarantee claim through the guarantee service Remember before you submit a guarantee claim contact our technical support using telephone or e mail More than 50 of operational problems is resolved remotely saving time and money spent to initiating guarantee procedure If remote support is insufficient the Customer shall fill the guarantee claim form using our website www fibargroup com in order to obtain claim authorization When the guarantee claim form is submitted correctly the Customer shall receive the claim confirmation with an unique number Return Merchandise Authorization RMA 6 The claim may be also submitted by telephone In this case the call is recorded and the Customer shall be informed about it by a consultant before submitting the claim Immediately after submitting the claim the consultant shall provide the Customer with the claim number RMA number