CDP UPO11-2 uninterruptible power supply (UPS)

image

Contents

1. 2 Remove the top cover of the UPS Install the SNMP slot kit onto the rear panel of the UPS S Insert the SNMP card into the SNMP slot as guided 5 Fasten the SNMP card properly and put the top cover of the UPS back to its position Cee cae Rone dace sh wn SNMP mode SNMP Card for configuration instruction Your hardware installation is now completed 14 www cdpups com 15 CHAPTER FOUR UPS Working Principle 4 1 When Utility is Normal The working principle of the UPS under Utility normal condition is illustrated as follows When Utility is normal the AC source is rectified to DC partially fed into the charger to charge battery and partially fed into inverter The inverter reverts the DC to AC to supply energy to the load connected The Utility LED and Inverter LED Light up 4 2 When Utility is Abnormal The working principle of the UPS under Utility abnormal condition is illustrated as follows When Utility is abnormal the UPS will direct the battery energy automatically to the Inverter and turn off the charger and AC DC converter The inverter revert DC to AC to supply energy to the output load connected The Inverter LED lights up When Utility is back to Normal the UPS will turn on the AC DC converter turn off DC DC converter and turn back charger to charging position It has the same working principle as figure 4 1 During a blackout the UPS will work as illustrated i
2. CHICAGO DIGITAL POWER High Frequence Ordine UPS User s Manual CHICAGO DIGITAL POWER Chicago Digital Power incorporat 193W Higgins Groove 140007 Tek 847 718 9545 847 718 9546 vista www cdpups com Important Safety Instructions TABLE OF CONTENTS An Important Notice Warning 4 Product Introduction 2 The General 3 The Advanced Technical Characteristics 2 Introduction to the Front and Rear Panel 2 1 Front Display Panel Explanation 6 22 Rear Panel Explanation 8 2 2 1 General Explanation M8 2 2 2 Terminal Blank 40 For TOWER Type 23 Communication Port Explanation mam 3 Installation and Operation 3 1 Unpacking 3 2 Selecting Installation Positio 3 3 Operation Test and Installation instruction 3 4 Storage Instruction 3 5 SNMP Slot 4 UPS Working Principle When Utility is When Utility is i Inverter Over Temperatur 46 Inverter Over current and Inverter Output Voltage Out of 5 Troubleshooting amp Maintenance Guide 5 1 System Block Diagram 20 Troubleshooting 20 5 3 Maintenance 21 6 Bundled Software Installation Guide 6 1 Hardware Installation 22
3. 2 Software Appendix A 1 Specification IMPORTANT SAFETY INSTRUCTIONS SAVE THIS INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries An Important Notice 2 Toensure safety in all applications where a UPS is hard wired to the Electrical Supply censure that the system is installed by a Qualified Electrical Contractor 1 Those UPS systems supplied with a factory input lead can be safely connected to the wall socket by the purchaser 1 The UPS has its own internal energy source battery Should the battery be switched on when no AC power is available there could be voltage at the output terminals 1 Make sure that the AC Utility outlet is correctly grounded 1 Do not open te cese e hers aro no secicettle peri Your Warranty be a Do notty to repair unit yours contact your local supper or your warranty wil Please make sure that the input voltage of the UPS matches the supply voltage Use a certified input power cable with the correct plugs and sockets for the appropriate voltage system To eliminate any overheating of the UPS keep all ventilation openings free from and do not sore Hinge on top of ths UPS Koop the UPS 20 om sway Make sure the UPS is installed within the proper environment as specified 0 40 C and 30 90 non condensing humidity Donot install the UPS in direct s
4. 3 Maintenance Clean the dust from the ventilation openings and intakes on the rear panel 1 Tum off the UPS and wipe the casing with a damp cloth 2 Periodically unplug the power cord of the UPS from the wall Receptacle to test the batteries condition 3 Be sure you have already saved your application before you proceed the battery discharging capability test 19 EE CHAPTER SIX Bundled Software Installation Guide 1 Hardware Installation 2 Connect the male connector of RUPS II cable to the UPS communication port 3 Connect the female connector of RUPS II cable to a dedicated RS232 port If there is only DB25 connector of the RS232 port available you may use a DB9 DB25 adapter to convert it 6 2 Software Installation 6 2 1 RUPS II Installation 1 RUPS Il for MS DOS 4 Kien delata lp your fiopoy dek execute INSTALL EXE under MS DOS A gt CD DOS lt Enter gt AADOS gt INSTALL lt Enter gt 2 Please select the MS DOS menu from the installation menu box give the path of RUPS II system diskette and the designated directory of it You may use the default value of RUPS II 3 The installation program will copy all required files of the RUPS II into the designated path It will also append a Load RUPS EXE Command in your AUTOEXEC BAT file automatically After a complete installation is done the installation program will execute the CONFIG EXE automatically You may modify the configurations of RUPS II
5. RS232 serial type It may be connected to a computer and allows the computer to monitor the status of UPS and controls the operation of the UPS via an additional UPS software kits The bundled software of the UPS is for Windows environment such as Windows 3 1 Windows 95 amp 98 Windows NT For other applications such as Novell NetWare Unix etc please contact your local distributor for a proper solution 2 3 1 The RS232 interface settings The RS232 interface shall be set as follows 232 The Pin Assignments of true RS232 type The Pin Assignments of true RS232 type are illustrated as follows Pin 6 RS232 Rx Pin 9 RS232 Tx Pin 7 Ground 10 www cdpups com 11 CHAPTER THREE Installation and Operation The packing condition and the external outlook of the unit should be inspected carefully before installation Retain the packing material for future use 3 1 Unpacking 1 Take the UPS out of the PE foam 2 Unwrap the UPS 41 The UPS itself is approx 12 5 39kgs so be careful when unpacking and lifting the unit Improper use of force might harm yourself 2 The plastic bag holding the UPS is very slippery so be careful in Unpacking and holding the unit The unit might drop accidentally and harm yourself 3 Standard Package includes User s Manual AC Input Power Cord Not available for hard wiring connection models 1 output cables for the UPS with IEC sockets only 2 RJ11 Ph
6. operation for preventing further supply please install a suitable external power switch or breaker between UPS output and loads oe kx CHAPTER ONE Product Introduction 2 The General Characteristics 1 True online architecture continuously supplies in your critical device with a stable regulated transient free pure sine wave AC Power 1 50KHz PWM sine wave topology yields an excellent overall performance 2 The high crest factor of the inverter handles all high inrush current loads without a need to upgrade the power rating 3 To protect the unit from overloading it automatically switches to bypass mode in case loading exceeds 120 of rating It will automatically switch back to inverter mode once overload condition ceases 4 Should the output becomes short circuited the UPS holds the system and cuts the output automatically till the short circuit situation is removed 5 Should the unit become overheated the internal thermistor will detect the heat and switch to bypass mode and vice versa Maintenance free sealed type battery minimizes after sales service wwwcodpupscom 4 1 2 The Advanced Technical Characteristics 2 Market leading light and compact design for modem OA environment and flexibility 3 Powerful CPU integrates all power stages control and communication functions necessary for maximized UPS protection and functionality including Power management status monitoring configuration setting operation S
7. advanced upgrade solution to achieve direct power management via internet world wide Introduction to the Front and Rear Panie m 2 1 Front Display Panel Explanation TEE TERRY Ht To execute 1e sl lest o Ie UPS by pressing the buon over 10 sec o For Unit with Manual Bypass function Speciat order required To press he button over 5 seconds the UPS wil www cdpups com 2 2 Rear Panel Explanation Aii ain epee into 1s to disconnect Ine Input to protect applic overload or short circuit __Fuse Breaker Rating for 120Vac Z30Vac systems 120Vac 20AI280V 120Vac 25A 250V 120 SOAI280V 230Vac 104 250 ac 20A 250V 230Vac 250 250 1 a battery terminal to be connected with additional banks for longer backup time purpose Only a d technician is permitted to proceed the installation modemiinteme RIT1 and 10 8 R AS protection against ine interterence www cdpups com 2 2 2 Terminal Black Explanation For 3KVA Tower Type 120V 230V OUTPUT G W T enererer ererge ee eieiemieue INPUT OUTPUT 2 3 Communication Port Explanation The communication port on the rear panel of the UPS is a true
8. cheduling remote control and self diagnosis 4 Slick CPU communication design allows full function remote control from any computer environment via standard RS 232 interface using Megatec s RUPSII protocol State of the Art IGBT Technology and Industrial Grade quality ensures Highest efficiency and reliability under worst operating condition 6 Industry leading inverter protection technology incorporates 2 stage output Current sensor smart overload output current control improved crest factor and feedback failure proof circuit elevating the availability of power service 7 Guarantees an exclusive protection against DC damage for inductive load Such as motor based devices entirely eliminating application limitation 8 Advanced Input PFC contcl guarentess the PE performance and boc energy efficient 87 Unique electronic over current protection detects output short circuit faults and halts output before damages done to output fuse or equipment thereby minimizing the need for service 10 Expanded input voltage working range minimizes battery usage and enhances battery utilization and life 11 Automatic Frequency Sensor reduces headache in frequency shift 12 DC start function makes sure of the start up of UPS during power outages 13 On demand self diagnosis function ensures UPS reliability and availability hc supplementary charger enables speediest charging of extemal Bank 15 SNMP lapter siot represents the
9. connect the input power cord of the UPS to wall receptacle then connect the power cord of your device to the output receptacle of the UPS 7 on the Main switch on the front panel The Utility LED and Inverter LED will light up in 7 10 seconds then turn on the switch of the device connected Do not execute any critical application yet 8 Disconnect the UPS from the wall receptacle to simulate Utility failure The Utility LED should extinguish and the alarm will sound continuously till battery cutoff The device connected to the UPS shall operate continuously To mute the audible alarm please push the Test Silence Button on the front panel 9 Your installation is done successfully 3 4 Storage Instruction For extended storage through moderate climate the batteries should be charged for 12 hours every 3 months by plugging the UPS power cord into the wall receptacle Repeat this every 2 months under high temperature environment 3 5 SNMP Slot You may install the SNMP card into the SNMP slot on the rear panel of the UPS The UPS may be connected to the network management system via the SNMP card The SNMP slot kit is an optional feature of the UPS so you shall purchase the kit from your local distributor before installing the SNMP card The installation shall be executed by a qualified technician authorized by your local distributor 13 1 The UPS shall be located in a proper location as described in Chapter 32
10. e in which case The user may be required to take additional measures Intended for Installation in a Controlled Environment Servicing of Batteries Should be Performed or Supervised by Personnel Knowledgeable of Batteries and the Required Precautions Keep Unauthorized Personnel Away from Batteries 6 When Replacing Batteries Replace With the Same Number and Type 7 CAUTION Do Not Dispose of Battery or Batteries in a fire The Battery May Explode 8 CAUTION Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 CAUTION Risk of Electric Shock Battery Circuit is not isolated from ac hazardous Voltage may exist between battery terminals and ground Test before touching 10 CAUTION A Battery can present a Risk of Electrical Shock and High Short Circuit Current The Following Precaution Should be Observed When Working on Batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminals 11 CAUTION To reduce the risk of fire connect only to a circuit provided with 50 amperes maximum branch circuit overcurrent in accordance with the National Electric Code ANSI NFPA 70 3KVA CAUTION In order to disconnect loads from UPS output in any mode
11. e UPS after short circuit condition is removed you Shali push the Main Switch on he front panel to OFF positon fst hen To position again 4 4 2 Output Short circuit under bypass Mode If output load is short circuited under bypass mode the AC fuse will trip open to prevent the output load from damage You shall replace a new fuse with same rating after the short circuit condition is eliminated 4 5 Inverter Over temperature If the UPS experiences over temperature when Utility is normal it will switch to bypass loop The UPS will switch back to inverter mode when the over temperature situation is eliminated If it happens when Utility is abnormal the buzzer will beep continuously and the Fault LED will light up The output of the UPS will also be cut off 4 6 Inverter Over current and Inverter Output Voltage Out of Window ifie UES Farbe divers end ost ciii veo fo output the UPS is out of order The UPS will switch to bypass loop Utility is normal The Utility LED Bypass LED and Fault LED pere If these two conditions occur when Utility is abnormal the UPS will turn off the Output and the Fault LED will ight up CHAPTER FIVE Maintenance Guide 5 2 Trouble Shooting When the UPS malfunctions during operation you may check the list Below for weer distent Shoukd te probiom persists your local distributor for help www cdpups com 18 5
12. er sounds continuously Fault LED lights up then cut the output Audible and Visual Line Failure Battery Low Transfer to Bypass Overload System Fault Conditions Temperature JOC A0T LLL 30 90 RH Maximum Non Condensing Noise 45 dB at 1 meter m SNMP tability Yes Slot for Standard SNMP Card Available alt Windows OS 2 NetLite MS DOS HP patibil tein Ur AIX SUN OS UNIX XENIX Linux etc ey Seren cUL Standard EN50091 2 EN61000 3 3 EN6 1000 3 2 FCC Class A Marks CE cUL Above specifications are subject to change without prior notice Trademarks of MegaTec RUPS IBM MS DOS Novell Netware Windows OS 2 HP UX AIX SUN UNIX and XENIX and Linux are registered trademarks of ther respecte companies www cdpups com 24
13. n figure 4 2 When Battery is low buzzer will beep continuously til battery is completely cut off The battery low protection of the UPS will cut off battery supply before battery drains to avoid from battery over drain The Inverter LED and Bat Low LED will light up till the UPS is completely cut off The UPS will re start automatically when Utility is back to Normal The working principle is the same as figure 4 1 4 3 Overload Condition The working principle of the UPS when overloading is illustrated as follows Normally an inrush current is generated when switching on the connected device If the UPS is in 105 120 loading it will switch to bypass mode in 60 seconds If The UPS is in 120 150 loading it will switch to bypass mode in 10 seconds If The UPS is over 150 loading it will switch to bypass mode immediately The Utility LED Bypass LED and Over Load LED light up If overload condition is eliminated by reducing the load to 80 90 the UPS will switch back to Inverter mode automatically 16 www cdpups com 17 4 4 Inverter is out of Order 4 4 1 Output short circuit under inverter mode If output load is short circuited under inverter mode the UPS will turn off the output to prevent load from damage The Fault LED lights up and the buzzer sounds continuously The UPS can not turn on automatically after short circuit condition is eliminated You are required to re start the UPS manually To re start th
14. n the File Server with access rights in SYS SYSTEM Execute b Di Netware V5 x Install exe 1 Re boot System 2 UPSilon 2000 for FreeBSD and Linux 1 109 in as a super user 2 Use the fp utility in MS DOS to copy files into the system directory tmp 3 Follow the instructions below to make the filename conversion after the File transfer linux z linux Z mv LINUX Z linux 2 chmod 755 install 4 Execute the installation program install 5 Select a target system from the menu and configure the UPSilon for Unix Make sure no other process using the same serial port the installation Program wil launch the UP Sion for Unhx daemon process automatically 22 www cdpups com 23 ac 1100 1 10 115 120 or 200 220 230 240 a ee Form Sine Wave THD lt 3 no load to full lo Vois Regulation equency Stability 0 5Hz Free Running 4 Under full load change and corrected within 60ms Respo frrewenaion True Slew Rate Inverter Free Running If input Over 5 Range Voltage Vc ite oe for extended back up application Charger Optional LED Unity Battery Low Inverter Bypass Self Test Load Level Battery Level Overload Fault Conditions MODEL 1KVA 2KVA 3KVA 10035 12096 delay 60 seconds before switching to bypass 120 150 delay 10 seconds before switching Bypas 1 Utility Abnormal Buzz
15. now 2 RUPS Il for Windows 3 1 Windows 95 98 Windows NT 1 Execute A Windowslsetup exe under Windows system This procedure can be achieved either by file manager or from the RUN command of Windows The RUPS II Setup group is labeled as RUPS2W you may Bici rei ideni 20 www cdpups com 21 C RUPS II for Novell Netware Optional 2 Login the File Server as a SUPERVISOR or a USER with Access Right in sub directory SYS SYSTEM FLOGIN SUPERVISOR 3 Insert the system diskette into the floppy disk Driver A 4 Execute INSTALL EXE in Driver A A INSTALL 5 After the installation is complete please shutdown your Operating System and re start it The system will load the PowerMan NLM and execute it 6 When the RUPS II for NetWare Is loaded the Filer Server will broadcast a successful loading message on the screen You may switch to the RUPS II Menu by pressing ALT_ESC simultaneously 6 2 2 UPSilon 2000 Installation 1 UPSilon 2000 for Windows 95 98 NT 1 From the Start Button choose Run 2 Type D Windows Setup exe 3 Choose OK 2 UPSilon 2000 for Novell Netware V3 1x 1 Login the File Server with access rights in SYS SYSTEM 2 Execute D Netware V3 1x Install exe 3 Re boot System 3 UPSilon 2000 for Novell Netware V4 x 1 Login the File Server with access rights in SYS SYSTEM 2 Execute D Netware V4 x install exe 3 Re boot System 4 UPSilon 2000 for Novell Netware V5 x a Logi
16. one Jack Cable S UPS communication kit optional 3 2 Selecting Installation Position Itis necessary to select a proper environment to install the unit in order to minimize the possibility of damage to the UPS and extend the life of the UPS Please follow the advice below 1 Keep at least 20 8 inches clearance from the rear panel of the UPS to the wall 2 Do not block the air flow to the ventilation openings of the unit 3 Please check the installation site to avoid overheat and excessive moisture 4 Do not place the UPS in an environment near dusty corruptive or salty material or flammable objects 5 Do not expose the UPS to outdoors 3 3 0peration Test and Installation Instruction The installation should be conducted or by a qualified technician to avoid accident Charge the UPS for more than 8 hours after unpacking to ensure the UPS is fully charged before usage 1 Make sure the grounding of wall receptacle is properly done aa epe match that of Utility then EUR AG ai poner DER 3 Tum on the Main switch on the front panel to start the UPS then the fan on the rear panel will spin 4 After 7 10 seconds the start up of UPS will be completed then the Utility LED and Inverter LED will light up simultaneously 5 Disconnect the input power cord of the UPS to see whether the UPS remains operation when Utility is abnormal 6 Re
17. unlight Your warranty may be void if the batteries fail Install the UPS indoors as itis not designed for installation outdoors Dusty corrosive and salty environments can do damage to any UPS Install the UPS away from objects which give off excessive heat and areas which are excessively wet liquids are split onto the UPS or foreign objects dropped into the unit the warranty will be null and void The battery wil discharge naturally if the system is unused for any length of time Itshould be recharged every 2 3 months if unused If this is not done then the warranty will be null and void When installed and being used the batteries will be automatically recharged and kept in top condition This UPS supports electronic equipment in offices telecommunications process control medical and security applications The UPS is not suitable for the application in inductive loads such as emergency light Please do not connect the UPS to any inductive load wwwcdpupscom 2 WARNING A 2 This UPS has been designed and constructed to protect your assets from the wide range of power aberrations experienced on Utility power lines today It is your insurance for reliable clean and stable voltage supply It is worth taking care to install the ayatam correcty and to have it maintained correct by your local This is a Class A UPS Product In a domestic environment This product may cause radio interferenc