Celestron 44102

image

Contents

1. e Ocular Huygens de 10x e Objetivo de 40x e Objetivo de 4x e 5 preparaciones en portaobjetos e Objetivo de 10x e Cubierta contra el polvo Especificaciones Modelo N 44102 Especificaciones Platina Platina lisa con presillas a resorte 120 mm x 110 mm Brazo Selecci n de ngulo de 0 a 60 Mecanismo de enfoque Perillas macrom trica y microm trica tope de seguridad de pi n y cremallera Objetivos Acrom tico 4x aumento de 40 10x aumento de 100 40x aumento de 400 Iluminador Espejo plano c ncavo de 50 mm Ocular 10x Campo visual de 12 mm Rev lver Triple con clic de parada Condensador N A 0 65 Diafragma Diafragma de disco con cinco tama os de apertura Desembalaje p armado del microscopio 1 Retire el contenedor de espuma de poliestireno de la caja de cart n 2 Quite la cinta del contenedor de poliestireno que sujeta las dos secciones 3 Retire cuidadosamente el microscopio y otras piezas del contenedor y col quelos sobre una mesa escritorio o cualquier otra superficie plana 4 Retire la bolsa de pl stico que cubre el microscopio 5 Quite el papel protector de la platina 5 6 Retire la tapa de pl stico del tubo del ocular 2 7 Inserte el ocular de 10x en el tubo del ocular 2 8 Retire los tres objetivos 4 de sus envases Desatornille las tapas de los envases de la porci n roscada de los objetivos 9 Enrosque el extremo del objetivo de 4 mm en uno de los agu
2. CELESTRON BEDIENUNGSANLEITUNG e Labormodell 44100 e Labormodell 44102 e Erweitertes Advanced Modell 44104 Erweitertes Advanced Modell 44106 Inhaltsberzeichnig Labormodel IEN Labo6rm dell44102 um E ee neun ehe lest eR RR ESPERE ER ERE D Erweitertes Advanced Modell 44104 ssssssccccosssssesevcsessssseecescccessssse D Erweitertes Advanced Modell 44106 ssssccccccosssscesecesosssssesesessssessss 13 Pflege ind Wartung ree er ves nuevo vuv eaae neuen a LO Garantie So is 19 Einf hrung Herzlichen Gl ckwunsch zum Kauf Ihres Celestron Mikroskops Ihr Mikroskop ist ein optisches Pr zisionsinstrument das aus Materialien von h chster Qualit t hergestellt ist um Haltbarkeit und eine lange Lebensdauer des Produkts zu gew hrleisten Es wurde entwickelt um Ihnen mit minimalen Wartungsanforderungen viele Jahre Freude zu bereiten Diese Bedienungsanleitung gilt f r vier Mikroskopmodelle Gehen Sie zum Abschnitt Ihres jeweiligen Mikroskopmodells damit Sie auch die richtigen Informationen lesen Lesen Sie diese Anleitung durch bevor Sie versuchen das Mikroskop zu benutzen um sich mit den Funktionen und Arbeitsabl ufen vertraut zu machen So werden Sie das Instrument optimal und zielgerichtet nutzen k nnen und viel Freude daran haben Die in diesem Handbuch beschriebenen Teile sind in den Abbildungen veranschaulicht Die in diesem Handbuch beschriebenen Mikroskope biet
3. INSTRUCTION MANUAL e Laboratory Model 44100 e Laboratory Model 44102 e Advanced Model 44104 Advanced Model 44106 Table of Contents Introducti n se WW E TT IO TN TO TOTA este 2 Laboratory Model 44100 AAA AAA J Laboratory Model 44102 sas neh D Advanced Model 44104 esee eee ee esa ee een e eon o een ernennen see een Advanced Model 44106 i Ia hn di uana dee ID Care and Maintenance EEN ae WAarranty EG A Introduction Congratulations on your purchase of a Celestron microscope Your microscope is a precision optical instrument made of the highest quality materials to ensure durability and long life It is designed to give you a lifetime of pleasure with a minimal amount of maintenance This instruction manual covers four microscope models Please be sure to locate your specific model of microscope in order to ensure you read the correct information Before attempting to use your microscope please read through the instructions to familiarize yourself with the functions and operations to maximize your enjoyment and usage See the microscope diagrams to locate the parts discussed in this manual The microscopes described in this manual provide high powers from 40 up to 1000x These microscopes types are ideally suited for examining specimen slides of yeasts and molds cultures plant and animal parts fibers bacteria etc The final section provides simple care and maintenance tips for you to follow
4. les d tails pr cis de l chantillon que vous observez agrandissez l ouverture du diaphragme iris pour laisser passer plus de lumi re L ouverture et la fermeture du diaphragme donnent une vue en relief de l chantillon et vous permettent de changer la profondeur de champ de l chantillon observ Utilisation de filtres Pour faire ressortir diff rents niveaux de d tails exp rimentez en changeant la couleur de l clairage de fond de l chantillon Pour changer la couleur de l clairage placez le filtre bleu vert ou jaune dans la trajectoire du faisceau lumineux en le mettant sur l illuminateur LED Il peut tre n cessaire de refaire une mise au point en r glant l g rement le bouton de mise au point fine 11 pour une meilleure qualit d observation Vous devriez exp rimenter avec chacune de ces couleurs pour voir les r sultats obtenus 17 PRettopage et entretien Votre microscope Celestron est un instrument de pr cision optique qu il convient de toujours manipuler avec soin Si vous respectez ces conseils de nettoyage et d entretien votre microscope ne n cessitera qu un entretien minimum pendant toute sa dur e de vie Lorsque vous avez fini de vous servir de votre microscope retirez tous les chantillons laiss s sur la platine Eteignez les boutons ou interrupteurs de l illuminateur lectrique D branchez tous les cordons d alimentation utilis s Recouvrez toujours le microscope avec la house de protection
5. En lugar de aumentar la intensidad de la luz del iluminador que puede difundir los detalles finos del esp cimen que est observando aumente la apertura del diafragma iris para que entre m s luz La apertura o cierre del diafragma le ofrece una vista en relieve del esp cimen y le permite cambiar la profundidad de campo del esp cimen que est observando Uso de filtros Para resaltar los diferentes niveles de detalle experimente cambiando el color de la iluminaci n trasera del esp cimen Para cambiar el color dela iluminaci n coloque el filtro azul verde o amarillo en la trayectoria luminosa colocando uno sobre el iluminador LED Quiz tenga que reenfocar ajustando la perilla microm trica 11 levemente para poder observar mejor Experimente con cada uno de los colores para ver los resultados 17 Cuidado p mantenimiento El microscopio Celestron es un instrumento ptico de precisi n que en todo momento debe ser tratado con cuidado Siga estas sugerencias de cuidado y mantenimiento y su microscopio necesitar muy poco mantenimiento durante su vida til Retire los espec menes de la platina cuando haya terminado de usar el microscopio Apague las perillas o interruptores de los iluminadores el ctricos Desenchufe el cord n el ctrico Coloque siempre la cubierta contra el polvo sobre el microscopio cuando no est en uso o cuando lo guarde Guarde el microscopio en un lugar seco y limpio Tenga cuidado si utiliza el mi
6. Insert the 10x eyepiece in the eyepiece tube 2 Remove the three objective lenses 4 from their containers Unscrew the container lids from the threaded portion of the objective lenses Thread the end of the 4mm objective lens into one of the holes on the nosepiece 12 until finger tight It may be necessary to lower the stage 5 by turning the coarse focus knob 3 10 Now turn the nosepiece to the next opening and thread each of the remaining objective lenses into the remaining holes You are now ready to use your microscope em oe ON A I Microscope Operation Using the Illuminator Mirror Your microscope has a built in plano concave illumination mirror which allows you to illuminate the specimen from the bottom by reflecting an external light source indirect sunlight room light lamp etc to the stage The mirror has a flat side you can easily see your reflection on the flat surface and a concave side The concave side will concentrate more light onto the specimen than the flat side To illuminate a specimen 1 Ifitis daylight tilt the mirror 6 and reflect indirect sunlight through the bottom of the stage 5 Warning Never use the mirror to focus direct sunlight through the microscope as this can be very harmful and may damage your eyes 2 If viewing at night or indoors away from sunlight you can use a nearby desk lamp table lamp or other light source to reflect light onto a specimen To control the amount of l
7. Perilla microm trica MECH 7 Base e CELESTRON Figura 4 Accesorios est ndar inclu dos con el microscopio e Ocular de 10x con puntero e Iluminador LED diodo luminiscente e Objetivo de 4x e Filtros verde amarillo azul e Objetivo de 10x e Aceite de inmersi n e Objetivo de 40x e 5 preparaciones en portaobjetos e Objetivo de 100x e Cubierta contra el polvo Especificaciones Modelo N 44106 Especificaciones Platina Platina mec nica de 115 mm x 125 mm Cabezal Monocular con inclinaci n de 45 y rotaci n de 360 Mecanismo de enfoque Perillas macrom trica y microm trica tope de seguridad de pi n y cremallera Objetivos Acrom tico 4x aumento de 40 10x aumento de 100 40x aumento de 400 100x aumento de 1000 Iluminador Espejo plano c ncavo de 50 mm Ocular Campo ancho de 10x con puntero Campo de visi n de 18 mm Rev lver Cu druple con clic de parada Condensador Abbe N A 1 25 Diafragma Iris 13 Desembalaje p armado del microscopio Retire el contenedor de espuma de poliestireno de la caja de carton 2 Quite la cinta del contenedor de poliestireno que sujeta las dos secciones 3 Retire cuidadosamente el microscopio y otras piezas del contenedor y col quelos sobre una mesa escritorio o cualquier otra superficie plana 4 Retire la bolsa de pl stico que cubre el microscopio 5 Quite el papel protector de la platina 5
8. Specimen Stage 6 LED Illuminator 13 On Off Switch ETE 7 Base e CELESTRON Figure 4 Standard Accessories with pour Microscope e 10x Eyepiece with pointer e LED Illuminator e 4x Objective Lens e Green Yellow Blue Filters e 10x Objective Lens e Immersion Oil e 40x Objective Lens e 5Prepared Slides e 100x Objective Lens e Dust Cover Specifications Model 44106 Specifications Stage Mechanical Stage 115mm x 125mm Head Monocular with 45 incline and 360 rotatable Focuser Coarse and Fine focus knobs Rack amp Pinion Safety Stop Objectives Achromatic 4x 40 power 10x 100 power 40x 400 power 100x 1000 power Illuminator 50mm Plano Concave Mirror Eyepiece 10x Wide Field with Pointer 18mm Field of View Nosepiece Quadruple with click stop Condenser Abbe N A 1 25 Diaphragm Iris 13 pr Setting Up Pour Microscope Take the Styrofoam container out of the cardboard carton Remove the tape from the Styrofoam container holding the two sections together Carefully remove the microscope and other parts from the container and set them on a table desk or other flat surface Remove the plastic bag covering the microscope Remove the protective paper from the stage 5 Remove the four objective lenses 4 from their containers Unscrew the container lids from the threaded portion of the objective lenses Thread the end of the 4mm objecti
9. ffnung und schrauben Sie die restlichen Objektivlinsen in die restlichen Offnungen Ihr Mikroskop ist jetzt einsatzbereit prr NE Betrieb des Mikroskops Verwendung des Beleuchtungsspiegels Das Mikroskop umfasst einen integrierten plankonkaven Beleuchtungsspiegel der die Beleuchtung der Probe von unten erm glicht indem er eine externe Lichtquelle indirektes Sonnenlicht Zimmerbeleuchtung Lampe etc auf den Objekttisch reflektiert Der Spiegel weist eine flache Seite Ihr Spiegelbild ist auf der flachen Oberfl che leicht zu sehen und eine konkave Seite auf Die konkave Seite konzentriert mehr Licht auf die Probe als die flache Seite Beleuchtung einer Probe 1 Bei Tageslicht Neigen Sie den Spiegel 6 so dass indirektes Sonnenlicht durch die Unterseite des Objekttisches reflektiert wird 5 Achtung Niemals mithilfe des Spiegels direktes Sonnenlicht durch das Mikroskop richten Das kann sehr gef hrlich sein und Ihre Augen k nnen Schaden davontragen 2 Bei Betrachtung nachts oder in Innenr umen ohne Sonneneinstrahlung k nnen Sie eine Schreibtisch oder Tischlampe oder andere Lichtquelle verwenden um Licht auf eine Probe zu reflektieren Regulierung der auf die Probe reflektierten Lichtmenge 1 Mit der konkaven Seite des Spiegels k nnen Sie mehr Licht auf den Objekttr ger fokussieren Die konkave Seite konzentriert mehr Licht auf Ihre Probe aber sie fokussiert einen kleineren Lichtstrahl der empfindlicher auf Einste
10. Platine mecanique 115 mm x 125 mm Potence Choix d angles de 09 60 Dispositif de Mise au point Boutons de mise au point grossiere et fine cr maill re et pignon avec but e de s curit Objectifs Achromatique 4x 10x 40x llluminateur Miroir plan et concave de 50 mm Champ de vision 10 mm 12 mm Champ de vision 12 5 mm Oculaires 10 mm Tourelle Triple avec but e a d clic Condenseur Abbe N A 1 25 Diaphragme Iris Tableau de grossissement Reportez vous au tableau ci dessous pour d terminer le grossissement des diff rentes combinaisons d oculaires objectifs de votre microscope Objectif 4x 10x 40x Oculaire 10x 40x 100x 400x Oculaire 12 5x 50x 125x 500x Installation de botre microscope Sortez la boite en polystyrene expans de son carton Retirez le ruban adh sif de la bo te en polystyr ne expans en maintenant les deux parties ensemble Retirez d licatement le microscope et les autres pi ces et installez les sur une table un bureau ou toute autre surface plane Retirez l emballage plastique prot geant le microscope Retirez le papier de protection de la platine 5 Retirer le cache en plastique du tube de l oculaire 2 Ins rez l oculaire 10x dans le tube de l oculaire 2 Retirez les trois objectifs 4 de leur conteneurs D vissez les caches du conteneur du filetage des objectifs Vissez l extr mit de l objectif de
11. Utilisez la face concave du miroir pour faire converger davantage de lumi re sur la lame porte objets La face concave permet de concentrer plus de lumi re sur votre chantillon mais le faisceau lumineux qu elle fait converger est plus troit ce qui rend son r glage plus d licat 2 S ilne vous est pas possible de r gler le miroir de mani re clairer correctement l chantillon vous pouvez incliner la potence 10 vers l arri re pour changer la position du miroir R glage de l angle de la potence La position d observation habituelle est de 0 Toutefois vous pouvez observer des chantillons en utilisant n importe quel angle compris entre 0 et 45 Pour changer l angle optique 1 Tenez le socle d une main 7 2 Ensuite inclinez la potence 10 avec l autre main la ramenant vers l arri re ou l avant selon l angle optique recherch Observation d un chantillon Placez d licatement une lame porte objets sous les leviers ressorts de la platine 8 et centrez l chantillon directement sur l orifice situ au centre de la platine 5 Vous pouvez maintenant faire une mise au point et observer l chantillon mais vous devez n anmoins prendre certaines pr cautions pour ne pas endommager la lame porte objets ou l objectif Votre microscope est quip d une but e de s curit 9 qui vous permet de r gler le trajet de la cr maill re sur le dispositif de mise au point Cette but e est destin e viter tout cont
12. dass der Objekttr ger die Objektivlinse ber hrt Das kann zu Zerbrechen des Objekttr gers und auch Zerkratzen der Objektivlinse f hren 12 Stellen Sie schlieBlich den Feintrieb 11 so ein dass Sie die sch rfste Einstellung erzielen Achtung Drehen Sie niemals beide Feintriebe gleichzeitig in die entgegengesetzte Richtung da der Fokussiermechanismus besch digt werden k nnte Tipp Bei der Betrachtung einer Probe mit der 100x Objektivlinse k nnen Sie das Aufl sungsverm gen verbessern indem Sie einen kleinen Tropfen Immersions l zwischen der Probe und Objektivlinse aufbringen Bei Proben Objekttr gern die Sie selbst herstellen bedecken Sie die Probe immer mit einer d nnen Glasscheibe und setzen den Oltropfen darauf Geben Sie das I nicht direkt auf die Probe auf 16 Einstellung der Beleuchtung Proben von unterschiedlicher GroBe Dicke und Farbvariation erfordern unterschiedliche Beleuchtungsstufen Es gibt drei Optionen zur nderung der Lichtmenge bei der Betrachtung einer Probe Einstellung der Helligkeit mit dem Ein Aus Knopf 13 Einstellung des Abbe Kondensors Abb 4g und Einstellung der Irisblende siehe Abb 4h 1 Bei der Betrachtung von nicht transparenten oder dunklen Proben empfiehlt es sich u U die Lichtmenge zu erh hen um bestimmte Merkmale oder Details aufzul sen Das erreicht man am besten durch die Erh hung der Helligkeit der LED Leuchte durch Drehen des Helligkeitsreglers am Ein Aus Schalter 13 in d
13. des trous de la tourelle 12 jusqu ce qu il soit bien serr Il peut tre n cessaire d abaisser la platine 5 en tournant le bouton de mise au point grossi re 3 Ensuite tournez la tourelle sur la prochaine ouverture et vissez tour de r le les autres objectifs dans les trous restants Vous tes maintenant pr t utiliser votre microscope Fonctionnement du microscope Utilisation du miroir illuminateur Votre microscope est quip d un miroir illuminateur int gr plan et concave qui vous permet d clairer l chantillon par dessous en r fl chissant une source externe de lumi re lumi re indirecte du soleil lumi re de la pi ce d une lampe etc sur la platine Le miroir poss de une surface plane sur laquelle il est vous est facile de voir votre reflet et une surface concave La face concave permet de faire converger davantage de lumi re sur l chantillon que la face plane Pour clairer un chantillon Si vous b n ficiez de la lumi re du jour inclinez le miroir 6 et r fl chissez la lumi re indirecte du soleil par dessous la platine 5 Avertissement Ne jamais utiliser le miroir pour faire converger la lumi re directe du soleil travers le microscope pour ne pas risquer de graves l sions oculaires Pour l observation de nuit ou l int rieur en ne b n ficiant pas de la lumi re du soleil vous pouvez utiliser une lampe de bureau de table ou toute autre source d clairage pour en r fl ch
14. e Objectif 4x e 5 lames porte objets pr par es e Objectif 10x e House de protection Specifications Modele n 44102 Sp cifications Platine Platine simple avec leviers ressorts 120 mm x 110 mm Potence Choix d angles de 0 60 Dispositif de mise au point Boutons de mise au point grossi re et fine cr maill re et pignon avec but e de s curit Achromatique 4x puissance 40 10x puissance 100 40x Objectifs puissance 400 llluminateur Miroir plan et concave de 50 mm Oculaire 10x Champ de vision 12 mm Tourelle Triple avec but e a d clic Condenseur N A 0 65 Diaphragme Diaphragme disgue avec cing tailles d ouverture wu uoo Sq aU PS 10 Installation de botre microscope Sortez la boite en polystyr ne expans de son carton Retirez le ruban adh sif de la bo te en polystyr ne expans en maintenant les deux parties ensemble Retirez d licatement le microscope et les autres pi ces et installez les sur une table un bureau ou toute autre surface plane Retirez l emballage plastique prot geant le microscope Retirez le papier de protection de la platine 5 Retirer le cache en plastique du tube de l oculaire 2 Ins rez l oculaire 10x dans le tube de l oculaire 2 Retirez les trois objectifs 4 de leur emballage D vissez les caches du conteneur du filetage des objectifs Vissez l extr mit de l objectif de 4 mm dans l un
15. found to be defective in materials or workmanship As a condition to the obligation of Celestron to repair or replace such product the product must be returned to Celestron together with proof of purchase satisfactory to Celestron B The Proper Return Authorization Number must be obtained from Celestron in advance of return Call Celestron at 310 328 9560 to receive the number to be displayed on the outside of your shipping container All returns must be accompanied by a written statement setting forth the name address and daytime telephone number of the owner together with a brief description of any claimed defects Parts or product for which replacement is made shall become the property of Celestron The customer shall be responsible for all costs of transportation and insurance both to and from the factory of Celestron and shall be required to prepay such costs Celestron shall use reasonable efforts to repair or replace any microscope covered by this warranty within thirty days of receipt In the event repair or replacement shall require more than thirty days Celestron shall notify the customer accordingly Celestron reserves the right to replace any product which has been discontinued from its product line with a new product of comparable value and function This warranty shall be void and of no force of effect in the event a covered product has been modified in design or function or subjected to abuse misuse mishandling or unauthorize
16. haya sido modificado en su dise o o funci n o haya sido maltratado usado indebidamente descuidado o reparado sin autorizaci n Adem s esta garant a no cubre el mal funcionamiento o deterioro debido al uso normal de este producto CELESTRON RECHAZA TODA OTRA GARANT A EXPRESA O IMPL CITA INCLUSO TODA GARANT A DE ADECUACI N O COMERCIABILIDAD PARA UN USO EN PARTICULAR EXCEPTO EN LA FORMA QUE SE INDICA EXPRESAMENTE EN ESTE DOCUMENTO LA NICA OBLIGACI N DE CELESTRON BAJO ESTA GARANT A LIMITADA SER LA REPARACI N O REEMPLAZO DEL PRODUCTO CUBIERTO DE ACUERDO CON LOS T RMINOS INDICADOS EN ESTE DOCUMENTO CELESTRON EXPRESAMENTE RECHAZA TODA P RDIDA DE GANANCIAS DA OS GENERALES ESPECIALES INDIRECTOS O FORTUITOS RESULTANTES DE ALG N ACTO DE INCUMPLIMIENTO DE LA GARANT A O DERIVADOS DEL USO O INHABILIDAD DE USAR CUALQUIERA DE LOS PRODUCTOS CELESTRON EL PER ODO DE DURACI N DE TODA GARANT A IMPL CITA Y QUE NO PUEDA SER DECLINADA SE LIMITAR A DOS A OS A PARTIR DE LA FECHA DE LA COMPRA AL POR MENOR ORIGINAL DE ESTE PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os fortuitos o consecuentes ni la limitaci n de la duraci n de una garant a impl cita de modo que las limitaciones o exclusiones anteriores pueden no corresponder a su caso Esta garant a le concede derechos legales espec ficos y es posible que a usted le correspondan otros derechos que var an de un estado a otro Celestron se reserva el
17. la cantidad de luz que se refleja en el esp cimen 1 Use el lado c ncavo del espejo para concentrar m s luz en el portaobjetos El lado c ncavo concentrar m s luz en el esp cimen pero concentrar un haz mucho m s peque o haci ndolo m s sensible para regular 2 Tambi n puede controlar la cantidad de luz con el condensador y el diafragma vea la secci n Ajuste de la luz Rotaci n del cabezal El cabezal del microscopio puede girar 360 Es as como puede observar desde cualquier posici n con solo mover el cabezal a la posici n deseada 14 Uso del iluminador LED diodo luminiscente a ts Figura 4a Figura 4b Figura 4c Para una luz m s directa e intensa use el iluminador LED diodo luminiscente suministrado El iluminador LED funciona con tres pilas AA no se incluyen 1 2 3 4 5 Tire hacia afuera el espejo luminoso para sacarlo de su sost n El tubo del iluminador LED se enrosca en sentido contrario a las agujas del reloj sobre el LED ubicado en la base del microscopio ver la Figura 4a Gire el tubo apret ndolo con los dedos ver la Figura 4b Instale las pilas ver la pr xima secci n Despu s de instalar las pilas gire el interruptor 13 a la posici n on de encendido Aseg rese de que el interruptor en la parte trasera de la base del microscopio est en la posici n Btry pila ver la Figura 4c Instalaci n de las pilas para el iluminador LED
18. lorsqu il n est pas utilis ou pour le ranger Rangez le microscope dans un lieu propre et sec Si vous utilisez votre microscope sous la lumi re directe du soleil faites tr s attention ne pas endommager l instrument ni vous abimer les yeux Lorsque vous d placez le microscope transportez le par la potence d une main et non par les boutons du dispositif de mise au point le porte oculaire etc Ensuite passez l autre main sous le socle pour le soutenir Nettoyez les surfaces externes m talliques et plastiques avec un chiffon humide D branchez toujours les cordons d alimentation avant le nettoyage Ne nettoyez jamais les surfaces optiques avec des chiffons ou serviettes en papier qui pourraient les rayer facilement liminez la poussi re des surfaces optiques avec une brosse en poils de chameau ou une buse de pulv risation Pour liminer les empreintes des surfaces optiques utilisez un agent de nettoyage pour objectifs et un chiffon sp cial disponibles dans pratiquement tous les magasins de photo et ne faites pas de cercles pour viter les filandres ou rayures Ne jamais d monter ni nettoyer les surfaces optiques internes Cette proc dure devrait tre confi e des techniciens qualifi s ou des centres de r parations agr s Lors de la manipulation des lames porte objets en verre faites attention aux bords coupants 18 Garantie Celestron de deux ans A Ce microscope est garanti par Celestron contre t
19. mer tags ber zu erreichen ist enth lt zusammen mit einer kurzen Beschreibung der beanstandeten Fehler Teile oder Produkte f r die ein Ersatz geliefert wird gehen in den Besitz von Celestron ber Der Kunde bernimmt alle Transport und Versicherungskosten und zwar f r den Transport zum Celestron Herstellungswerk sowie die R cksendung zum Kunden Diese Kosten m ssen im Voraus bezahlt werden Celestron unternimmt alle angemessenen Anstrengungen um ein Mikroskop das dieser Garantie unterliegt innerhalb von drei ig Tagen nach Eingang zu reparieren oder ersetzen Sollte eine Reparatur oder Ersatzleistung l nger als dreiBig Tage erfordern teilt Celestron dies dem Kunden entsprechend mit Celestron beh lt sich das Recht vor alle Produkte die nicht mehr hergestellt werden durch ein neues Produkt mit vergleichbarem Wert und Funktion zu ersetzen Diese Garantie wird null und nichtig und hat keine Wirkung wenn ein durch sie gedecktes Produkt im Design bzw Funktion modifiziert wurde oder falscher Verwendung Missbrauch Fehlbehandlung oder nicht autorisierter Reparatur unterzogen wurde Des Weiteren deckt diese Garantie auch keine Funktionsst rung des Produkts oder Einwirkungssch den aufgrund normaler Abnutzung ab CELESTRON LEHNT HIERMIT ALLE AUSDR CKLICHEN ODER STILLSCHWEIGENDEN GARANTIEN DER MARKTGANGIGKEIT ODER EIGNUNG F R EINEN BESTIMMTEN ZWECK AB AUSSER WENN SIE HIER AUSDR CKLICH DARGELEGT SIND DIE EINZIGE VERPFLICHTUNG SEITE
20. off any electric illuminator knobs or switches Unplug any power cords being used Always place the dust cover over the microscope when not in use or when being stored Store the microscope in a dry and clean place Be very careful if using your microscope in direct sun light to prevent damage to the microscope or your eyes When moving your telescope carry it by the arm with one hand and not by the focuser knobs eyepiece housing etc Then put your other hand under the base for support Clean the outside surfaces metal and plastics with a moist cloth Always unplug any cords before cleaning Never clean optical surfaces with cloth or paper towels as they can scratch optical surfaces easily Blow off dust with a camels hair brush or an air blower from optical surfaces To clean fingerprints off of optical surfaces use a lens cleaning agent and lens tissue available at most photo outlets and when cleaning do not rub in circles as this may cause sleeks or scratches to occur Never disassemble or clean internal optical surfaces This should be done by qualified technicians at the factory or other authorized repair facilities When handling glass specimen slides be care as the edges can be sharp 18 Celestron Two Bear Warranty A Celestron warrants this microscope to be free from defects in materials and workmanship for two years Celestron will repair or replace such product or part thereof which upon inspection by Celestron is
21. pero concentrar un haz mucho m s peque o haci ndolo m s sensible para regular 2 Si no puede regular el espejo para que ilumine el esp cimen correctamente puede cambiar la posici n del espejo inclinando el brazo 10 hacia atr s 3 La cantidad de luz tambi n se puede controlar haciendo girar el diafragma de disco de cinco aperturas ver Figura 2a debajo de la platina 5 Ajuste del ngulo del brazo La posici n normal de observaci n es 0 Sin embargo tambi n se puede hacer desde cualquier ngulo de 0 a 60 Para cambiar el ngulo de observaci n 1 Sostengala base con una mano 7 2 Conla otra mano incline el brazo 10 movi ndolo hacia adelante o hacia atr s hasta el ngulo de observaci n deseado Condensador Diafragma de disco Figura 2a Observaci n del esp cimen Cuidadosamente coloque un portaobjetos debajo de las presillas a resorte de la platina 8 y centre el esp cimen directamente sobre el agujero en el centro de la platina 5 Ahora est listo para enfocar y observar el esp cimen pero primero debe tomar ciertas precauciones para no da ar el portaobjetos o el objetivo El microscopio est equipado con un tope de seguridad de la platina 9 que permite regular la distancia de recorrido del mecanismo de enfoque Esto asegura que el objetivo no haga contacto accidentalmente con el portaobjetos ya que podr a romperlo o podr a rayarse el objetivo Para regular la distancia de recorrido del
22. resorte 88 mm x 88 mm Brazo Selecci n de ngulo de 0 a 45 Mecanismo de enfoque Macrom trico mecanismo con pi n y cremallera con tope de seguridad Objetivo Acrom tico 20x Iluminador Espejo plano c ncavo de 42 mm 10x Campo visual de 12 mm Desembalaje p armado del microscopio Retire el contenedor de espuma de poliestireno de la caja de cart n Quite la cinta del contenedor de poliestireno que sujeta las dos secciones Retire cuidadosamente el microscopio y otras piezas y col quelos sobre una mesa escritorio o cualquier otra superficie plana Retire la bolsa de pl stico que cubre el microscopio Quite el papel protector de la platina 5 Retire la tapa de pl stico del tubo del ocular 2 Inserte el ocular de 10x en el tubo del ocular 2 Ahora puede usar su microscopio SUSO VO Une anejo del microscopio Uso del espejo luminoso El microscopio cuenta con un espejo luminoso plano c ncavo incorporado que permite iluminar el esp cimen desde abajo reflejando en la platina una fuente de luz externa luz solar indirecta luz de la habitaci n l mpara etc El espejo tiene un lado plano usted puede ver su reflejo en la superficie plana y un lado c ncavo El lado c ncavo concentra mucha m s luz sobre el esp cimen que el lado plano Para iluminar el esp cimen 1 Si tiene luz natural incline el espejo 6 y refleje la luz indirecta desde la parte de abajo de la platina 5 Advertencia Nunca
23. your specimen but will focus a smaller beam of light making it more sensitive to adjust If you are unable to adjust the mirror enough to properly illuminate the specimen you can also tilt the arm 10 backward to change the position of the mirror The amount of light can also be controlled by rotating the five aperture size disc diaphragm see figure 2a underneath the specimen stage 5 Adjusting the Arm Angle The normal viewing position is at 0 However you can view at any angle from 0 to 60 To change the viewing angle 1 With one hand hold the base 7 2 Then with your other hand tilt the arm 10 by pulling it backward or forward to the desired viewing angle Condenser Disc Diaphragm Figure 2a Viewing a Specimen Carefully place a specimen slide under the spring loaded stage clips 8 and center the specimen directly over the hole in the center of the stage 5 You are now ready to focus and view the specimen but first you must take some precautions so as not to damage the specimen slide or objective lens Your microscope is equipped with a safety rack stop 9 which allows you to regulate the range of travel on the focuser This assures that the objective lens will not accidentally come into contact with the specimen slide breaking the slide or scratching the objective lens To adjust the travel on the focus mechanism 1 Raise the objective lens away from the specimen stage 5 by rotating the coarse focus
24. zerbrochen oder die Objektivlinse zerkratzt werden Einstellung des Bewegungsbereichs am Fokusmechanismus 1 Heben Sie die Objektivlinse vom Objekttisch 5 ab indem Sie den Grobtriebknopf 3 nach hinten drehen im Uhrzeigersinn 2 Drehen Sie die Anschlagschutzschraube 9 ca 2 3 heraus 3 Drehen Sie den Revolver 12 bis sich die 40x Linse ber der Probe befindet 4 Lassen Sie die Objektivlinse auf den Objekttr ger herab bis die Spitze der Linse sich kurz ber dem Objekttr ger befindet Aufpassen dass die Objektivlinse nicht mit dem Objekttr ger in Kontakt kommt 5 Drehen Sie die Anschlagschutzschraube 9 nach oben bis sie am Fokusmechanismus auftrifft 6 Drehen Sie die R ndelmutter nach oben um die Anschlagschutzschraube in dieser Stellung zu arretieren Fokussierung Jetzt wo sich der Objekttr ger direkt unter der Objektivlinse befindet nehmen Sie die Fokussierung der Probe mit dem Grobtriebknopf 3 vor 1 Beginnen Sie immer mit der kleinsten VergroBerung 4x Objektivlinse und gehen Sie zu den groBeren Vergr erungen ber indem Sie den Revolver 12 auf die 10x und dann die 40x Objektivlinse drehen Beim Wechsel zur h heren Vergr erung darf die Objektivlinse nicht den Objektivtr ger ber hren 2 Nun k nnen Sie mit dem Feintriebknopf 11 die Sch rfentiefe ndern und die untersuchte Probe pr zise und scharf einstellen 3 Bei begrenztem Abw rtsbewegungsbereich in dem sich noch keine scharfe Einstellung
25. zu den h heren Vergr erungen hinaufarbeiten 11 Schauen Sie durch das Okular w hrend Sie den Grobtriebknopf 3 drehen bis die Probe ins Sichtfeld r ckt Sie m ssen eventuell die Objekttischkn pfe Abb 3e leicht einstellen um die Probe im Sichtfeld zu zentrieren Achtung Achten Sie darauf dass Sie bei der Fokussierung den Probenobjekttisch nicht so hoch anheben dass der Objekttr ger die Objektivlinse ber hrt Das kann zu Zerbrechen des Objekttr gers und auch Zerkratzen der Objektivlinse f hren 12 Stellen Sie schlieBlich den Feintrieb 11 so ein dass Sie die sch rfste Einstellung erzielen Achtung Drehen Sie niemals beide Feintriebe gleichzeitig in die entgegengesetzte Richtung da der Fokussiermechanismus besch digt werden k nnte Abbe Kondensor Kondensor Reglerknopf Irisblenden Hebel Abb 3f 11 Einstellung der Beleuchtung Proben von unterschiedlicher Gr e Dicke und Farbvariation erfordern unterschiedliche Beleuchtungsstufen Es gibt zwei M glichkeiten zur Anderung der Lichtmenge bei der Betrachtung von Proben Einstellung des Abbe Kondensors und Einstellung der Irisblende siehe Abb 3f 1 Bei der Betrachtung mit Objektivlinsen kleinerer Vergr erung 4x und 10x m ssen Sie die Kondensorlinse absenken um das Licht ber das gr Bere Sichtfeld zu verteilen Zur Anderung der Position des Kondensors drehen Sie einfach den Kondensor Regelknopf im Uhrzeigersinn bis der Lichtstrahl sich weit genug a
26. 0 212 5835 www celestron com Montag bis Freitag 8 bis 16 Uhr US Pazifikzeit Diese Garantie tritt an die Stelle aller anderen Produktgarantien HINWEIS Diese Garantie ist g ltig f r US amerikanische oder kanadische Kunden die dieses Produkt von einem autorisierten Celestron H ndler in den USA oder Kanada erworben haben Die Garantie auferhalb der USA und Kanada ist nur f r Kunden g ltig die das Produkt von einem Celestron Vertriebsh ndler oder autorisierten Celestron H ndler in dem jeweiligen Land erworben haben F r Kundendienst unter Garantie wenden Sie sich bitte an diese H ndler 19 CELESTRON Celestron 2835 Columbia Street Torrance Ca 90503 U S A Tel 310 328 9560 Fax 310 212 5835 Web www celestron com Copyright 2007 All rights reserved Products or instructions may change without notice or obligation Printed in China 10 00 04 07
27. 2 You can also control light adjustment with the condenser and diaphragm see the section under Adjusting the Lighting Rotating the Head The head of your microscope can be rotated 360 Therefore you can view from any position by just moving the head to the desired location 14 Using the LED Illuminator e Figure 4a Figure 4b Figure 4c For more direct and intensive light you should use the supplied LED illuminator The LED illuminator is powered by three AA batteries user supplied 1 Remove the mirror illuminator by pulling it outward from its sleeve The LED illuminator tube will thread counterclockwise on over the LED s in the base of the microscope see Figure 4a Turn the tube until finger tight see Figure 4b Install the batteries see the next section below After the batteries are installed turn the power switch 13 to the on position Make sure that on the back of the microscope base that the switch is in the Btry position see Figure 4c HE Installing Batteries for the LED Illuminator Figure 4d Figure 4e Figure 4f To install the three AA batteries 1 Turn the microscope on its side 2 Witha small Phillips head screwdriver remove the four screws rubber feet at the bottom of the base and the screen can then be removed see Figure 4d Remove the two shiny Phillips head screws holding a bracket which keeps the battery box in place see Figure 4e Sl
28. 4 mm dans l un des trous de la tourelle 12 jusqu ce qu il soit bien serr Il peut tre n cessaire d abaisser la platine 5 en tournant le bouton de mise au point grossi re 3 10 Ensuite tournez la tourelle sur la prochaine ouverture et vissez tour de r le les autres objectifs dans les trous restants Vous tes maintenant pr t utiliser votre microscope of EE ON Un de Fonctionnement du microscope Utilisation du miroir illuminateur Votre microscope est quip d un miroir illuminateur int gr plan et concave qui vous permet d clairer l chantillon par dessous en r fl chissant une source externe de lumi re lumi re indirecte du soleil lumi re de la pi ce d une lampe etc sur la platine Le miroir poss de une surface plane sur laquelle il est vous est facile de voir votre reflet et une surface concave La face concave permet de faire converger davantage de lumi re sur l chantillon que la face plane Pour clairer un chantillon 1 Si vous b n ficiez de la lumi re du jour inclinez le miroir 6 et r fl chissez la lumi re indirecte du soleil par dessous la platine 5 Avertissement Ne jamais utiliser le miroir pour faire converger la lumi re directe du soleil travers le microscope pour ne pas risquer de graves l sions oculaires 2 Pour l observation de nuit ou l int rieur en ne b n ficiant pas de la lumi re du soleil vous pouvez utiliser une lampe de bureau de table ou t
29. 6 Retire los cuatro objetivos 4 de sus envases Desatornille las tapas de los envases de la porci n roscada de los objetivos 7 Enrosque el extremo del objetivo de 4 mm en uno de los agujeros del rev lver 12 apret ndolo con los dedos En caso de ser necesario baje la platina 5 haciendo girar la perilla macrom trica 3 8 Haga girar el rev lver a la pr xima abertura y enrosque cada uno de los objetivos restantes en los agujeros correspondientes iAhora est listo para usar el microscopio anejo del microscopio Uso del espejo luminoso El microscopio cuenta con un espejo luminoso plano c ncavo incorporado que permite iluminar el esp cimen desde abajo reflejando en la platina una fuente de luz externa luz solar indirecta luz de la habitaci n l mpara etc El espejo tiene un lado plano usted puede ver su reflejo en la superficie plana y un lado c ncavo El lado c ncavo concentra mucha m s luz sobre el esp cimen que el lado plano Para iluminar el esp cimen 1 Si tiene luz natural incline el espejo 6 y refleje la luz indirecta desde la parte de abajo de la platina 5 Advertencia Nunca utilice el espejo para concentrar la luz solar directa a trav s del microscopio ya que puede ser muy da ina y da ar la vista 2 Si se utiliza en la noche o adentro sin luz solar puede usar una l mpara de escritorio cercana una l mpara de mesa u otra fuente luminosa para reflejar la luz sobre el esp cimen Para controlar
30. NS CELESTRON IM RAHMEN DIESER EINGESCHRANKTEN GARANTIE IST DIE REPARATUR ODER DER ERSATZ DES PRODUKTS IN BEREINSTIMMUNG MIT DEN HIER DARGELEGTEN BEDINGUNGEN CELESTRON LEHNT AUSDR CKLICH JEGLICHE HAFTUNG F R ENTGANGENE GEWINNE ALLGEMEINE SPEZIELLE INDIREKTE SONDER ODER FOLGESCHADEN AB DIE SICH AUS EINEM GARANTIEVERSTOSS ODER DER VERWENDUNG ODER UNFAHIGKEIT DER VERWENDUNG EINES CELESTRON PRODUKTS ERGEBEN AB ALLE STILLSCHWEIGENDEN GARANTIEN DIE NICHT ABGELEHNT WERDEN K NNEN SIND IN IHRER DAUER AUF DEN ZEITRAUM VON ZWEI JAHREN AB DEM DATUM DES URSPR NGLICHEN KAUFS IM EINZELHANDEL BESCHR NKT In manchen L ndern ist ein Ausschluss oder eine Beschr nkung von Haftung f r Neben bzw Folgesch den oder eine Beschr nkung der Dauer der stillschweigenden Garantie unzul ssig so dass die vorstehenden Garantiebeschr nkungen oder Ausschlussklauseln u U nicht auf Sie zutreffen Diese Garantie verleiht Ihnen spezielle gesetzlich verbriefte Rechte Sie k nnen auch andere von Land zu Land verschiedene Rechte haben Celestron beh lt sich das Recht vor Mikroskopmodelle bzw typen zu ndern oder die Produktion einzustellen ohne Ihnen eine vorherige Mitteilung dar ber zukommen zu lassen Bei Auftreten eines Garantieproblems oder wenn Sie Hilfe bei der Verwendung Ihres Mikroskops ben tigen nehmen Sie Kontakt auf mit Celestron Technical Support Department 2835 Columbia Street Torrance CA 90503 USA Tel 1 310 328 9560 Fax 1 31
31. a le client en cons quence Celestron se r serve le droit de remplacer tout produit dont la production a cess par un nouveau produit de valeur et fonction comparables Cette garantie est nulle et non avenue si un produit couvert par la garantie a t modifi de mani re conceptuelle ou fonctionnelle ou s il a t soumis une utilisation abusive ou impropre ou encore des r parations non autoris es En outre tout fonctionnement d fectueux ou toute d t rioration du produit dus une usure normale ne sont pas couverts par la garantie CELESTRON REJETTE TOUTE RESPONSABILIT EN CAS DE GARANTIE EXPLICITE OU IMPLICITE QU IL S AGISSE DE QUALIT MARCHANDE OU D AD QUATION UN USAGE PARTICULIER SAUF SI ELLE EST EXPR SSEMENT TABLIE DANS LA PRESENTE DANS LE CADRE DE CETTE GARANTIE LIMIT E LA SEULE OBLIGATION DE CELESTRON CONSISTE R PARER OU REMPLACER LE PRODUIT SOUS GARANTIE CONFORM MENT AUX TERMES LA PR SENTE CELESTRON REJETTE EXPR SSEMENT TOUTE RESPONSABILIT EN CAS DE PERTES DE PROFITS OU DE DOMMAGES G N RAUX PARTICULIERS OU INDIRECTS R SULTANT D UNE RUPTURE D UN CONTRAT DE GARANTIE OU SURVENANT SUITE L UTILISATION OU L IMPOSSIBILIT D UTILISER UN PRODUIT CELESTRON TOUTES LES GARANTIES DE NATURE IMPLICITE QUI NE PEUVENT TRE REJET ES SERONT LIMIT ES A UNE DUR E DE DEUX ANS A COMPTER DE LA DATE INTIALE D ACHAT AU D TAIL Certains tats s opposent aux exclusions ou limites concernant les dommages cons c
32. a vis de s curit en position D 10 Pince valet Remarque Le bouton de d placement sup rieur de de la platine la platine se d place sur l axe des X en avant et en arri re alors que le bouton de d placement inf rieur de la platine se d place sur l axe des Y lat ralement L utilisation sur les deux axes d une chelle vernier permet de marquer et de copier avec pr cision un objet dans le champ de vision sur lequel l observateur peut souhaiter revenir Boutons de d placement de la platine Figure 3e Conseil utile Pour positionner l chantillon directement sous l objectif r duisez l ouverture du diaphragme iris voir Figure 3f jusqu ce qu il soit pratiquement ferm Vous devriez apercevoir un petit faisceau lumineux projet sur la lame porte objets Maintenant utilisez simplement les boutons de d placement de la platine pour d placer l chantillon l int rieur du faisceau lumineux 10 Utilisez la tourelle 12 pour tournez les objectifs 4 jusqu ce que l objectif 4x soit directement au dessus de l chantillon Commencez toujours avec l objectif de plus faible puissance en passant progressivement des puissances sup rieures 11 Regardez dans l oculaire en tournant le bouton de mise au point grossi re 3 jusqu ce que l chantillon soit visible Il peut tre n cessaire de r gler l g rement les boutons de la platine Figure 3e pour centrer l chantillon dans le champ de vision Ave
33. act accidentel de l objectif et de la lame porte objets afin de ne pas briser la lame ou de rayer l objectif Pour r gler le trajet sur le m canisme de mise au point 1 Relevez l objectif 5 en tournant le bouton de mise au point 3 vers l arri re sens horaire pour l loigner de la platine 2 D vissez la vis d arr t 9 de la but e de s curit de la cr maill re sur environ 2 3 de la longueur 3 Abaissez l objectif sur la lame porte objets jusqu ce que l extr mit de l objectif se trouve l g rement au dessus de la lame Veillez ne pas toucher la lame porte objets avec l objectif Vissez la vis de s curit 9 vers le haut jusqu ce qu elle butte contre le m canisme de mise au point Tournez le contre crou molet vers le haut pour bloquer la vis de s curit en position Ensuite tournez le bouton de mise au point 3 jusqu ce que l chantillon apparaisse nettement Qva am 4 Microscope de laboratoire Mod le n 44102 10 Potence 11 Bouton de mise a fi point fine 9 But e de s curit de la cr maill re EA o 1 Oculaire 2 Tube de l oculaire ur 3 Bouton de mise au point grossiere 12 Tourelle 4 Objectif Due 5 Platine chantillons 8 Leviers ressorts D diy y de la platine I as f 6 Miroir illuminateur CELESTRON 7 Socle Figure 2 Accessoires standard libres aber botre microscope e Oculaire de Huygens 10x e Objectif 40x
34. age 5 4 Place the illuminator pin and clips over the sleeve and push until it is in all the way see Figure 3c 5 Plugin the cord of the electric illuminator to the proper AC power source see Figure 3d Changing Eyepieces Your microscope is supplied with both 10x and 12 5x eyepieces They are easily interchanged 1 Remove either eyepiece 1 from the eyepiece tube 2 by pulling it upward 2 Install the desired eyepiece 1 into the eyepiece tube 2 by pushing downward 3 The eyepieces are held in place by a friction fit Viewing a Specimen Your instrument is provided with a mechanical stage with a stage holder clamp and directional knobs see figure 3e 1 Use the clamp lever to open the clamping arm of the stage holder clamp 2 Place a specimen slide 3 size inside the holder and gently close the clamping arm against the slide 3 Use the stage movement knobs see Figure 3e to position the specimen over the opening in the stage 5 You are now ready to focus and view the specimen but first you must take some precautions so as not to damage the specimen slide or objective lens Your microscope is equipped with a safety rack stop 9 which allows you to regulate the range of travel on the focuser This assures that the objective lens will not accidentally come into contact with the specimen slide breaking the slide or scratching the objective lens To adjust the travel on the focus mechanism 4 Raise the objective lens away
35. ard or forward to the desired viewing angle Viewing a Specimen Carefully place a specimen slide under the spring loaded stage clips 8 and center the specimen directly over the hole in the center of the stage 5 You are now ready to focus and view the specimen but first you must take some precautions so as not to damage the specimen slide or objective lens Your microscope is equipped with a safety rack stop 9 which allows you to regulate the range of travel on the focuser This assures that the objective lens will not accidentally come into contact with the specimen slide breaking the slide or scratching the objective lens To adjust the travel on the focus mechanism 1 Raise the objective lens away from the specimen stage 5 by rotating the focus knob 3 backwards clockwise 2 Unthread the safety rack stop screw 9 about 2 3 of the way 3 Lower the objective lens over the slide until the tip of the lens is slightly above the specimen slide Be careful not to touch the objective lens to the slide 4 Thread the safety screw 9 upward until it stops against the focus mechanism Rotate the knurled locking nut upward to lock the safety screw in place 6 Now turn the focus knob 3 until the specimen comes into sharp focus m Laboratory Microscope Model ff 44102 20 Arm A 11 Fine Focus Knob 1 Eyepiece 2 Eyepiece Tube ul 3 Coarse Focus Knob ee 4 12 Nosepiece 9 Safety Rack Stop 8 Sprin
36. cave illumination mirror which allows you to illuminate the specimen from the bottom by reflecting an external light source indirect sunlight room light lamp etc to the stage The mirror has a flat side you can easily see your reflection on the flat surface and a concave side The concave side will concentrate more light onto the specimen than the flat side To illuminate a specimen 1 Ifitis daylight tilt the mirror 6 and reflect indirect sunlight through the bottom of the stage 5 Warning Never use the mirror to focus direct sunlight through the microscope as this can be very harmful and may damage your eyes 2 If viewing at night or indoors away from sunlight you can use a nearby desk lamp table lamp or other light source to reflect light onto a specimen To control the amount of light reflecting onto the specimen 1 Use the concave side of the mirror to focus more light on the slide The concave side will concentrate more light onto your specimen but will focus a smaller beam of light making it more sensitive to adjust 2 If you are unable to adjust the mirror enough to properly illuminate the specimen you can also tilt the arm 10 backwards to change the position of the mirror Adjusting the Arm Angle The normal viewing position is at 0 However you can view at any angle from 0 to 45 To change the viewing angle 1 With one hand hold the base 7 2 Then with your other hand tilt the arm 10 by pulling it backw
37. chtmenge 1 Mit der konkaven Seite des Spiegels k nnen Sie mehr Licht auf den Objekttr ger fokussieren Die konkave Seite konzentriert mehr Licht auf Ihre Probe aber sie fokussiert einen kleineren Lichtstrahl der empfindlicher auf Einstellung reagiert 2 Wenn Sie den Spiegel nicht so einstellen k nnen dass die Probe ausreichend beleuchtet wird k nnen Sie auch den Arm 10 nach hinten neigen um die Position des Spiegels zu ndern Einstellung des Armwinkels Die normale Betrachtungsposition ist bei 0 Es sind aber auch andere Betrachtungswinkel von 0 bis 45 m glich Anderung des Betrachtungswinkels 1 Halten Sie den Mikroskopfu 7 mit einer Hand fest 2 Neigen Sie dann mit der anderen Hand den Arm 10 indem Sie ihn nach hinten oder vorn in den gew nschten Betrachtungswinkel ziehen Betrachtung einer Probe Setzen Sie vorsichtig einen Proben Objekttr ger unter die Federklemmen 8 des Objekttisches und zentrieren Sie die Probe genau ber der Offnung in der Mitte des Objekttisches 5 Jetzt k nnen Sie das Mikroskop scharf einstellen und die Probe betrachten aber zuerst m ssen Sie noch einige VorsichtsmaBnahmen ergreifen damit der Objekttr ger oder die Objektivlinse nicht besch digt werden Ihr Mikroskop ist mit einem Anschlagschutz 9 versehen der die Regulierung des Bewegungsbereichs am Fokussierer erm glicht Damit wird sichergestellt dass die Objektivlinse nicht versehentlich mit dem Objekttr ger in Kontakt k
38. ci n de la obligaci n de Celestron de reparar o reemplazar dicho producto el producto deber ser devuelto a Celestron con prueba de compra satisfactoria para Celestron B El N mero de Autorizaci n de Devoluci n Apropiado se debe obtener de Celestron antes de proceder con la devoluci n Llame a Celestron al 310 328 9560 para obtener el n mero que deber estar visible en la parte exterior del contenedor de env o Todas las devoluciones deben estar acompa adas por una declaraci n escrita donde debe figurar el nombre direcci n y n mero de tel fono diurno del due o junto con una breve descripci n de cualquier defecto reclamado El producto o las partes reemplazadas pasar n a ser propiedad de Celestron El cliente se har responsable de todos los costos de transporte y seguro tanto a la f brica como de la f brica de Celestron y se le exigir que dichos costos sean prepagados Celestron utilizar los medios razonables necesarios para reparar o reemplazar cualquier microscopio cubierto por esta garant a dentro de los treinta d as siguientes a su recibo En el caso de reparaciones o reemplazo que requieran m s de treinta d as Celestron notificar la demora al cliente Celestron se reserva el derecho a reemplazar cualquier producto que haya discontinuado de su l nea de productos con un producto nuevo de valor y funciones comparables Esta garant a ser nula y no tendr vigencia o efecto en el caso que el producto cubierto
39. cierre suavemente el brazo de sujeci n contra el portaobjetos 3 Use las perillas de movimiento de la platina ver la Figura 3e para colocar el esp cimen sobre la abertura en la platina 5 Ahora est listo para enfocar y observar el esp cimen pero primero debe tomar ciertas precauciones para no da ar el portaobjetos o el objetivo El microscopio est equipado con un tope de seguridad de la platina 9 que permite regular la distancia de recorrido del mecanismo de enfoque Esto asegura que el objetivo no haga contacto accidentalmente con el portaobjetos ya que podr a romperlo o podr a rayarse el objetivo Para regular la distancia de recorrido del mecanismo de enfoque 4 Haga girar la perilla macrom trica 3 hacia atr s en el sentido de las agujas del reloj para elevar el objetivo alej ndolo de la platina 5 5 Desenrosque unos 2 3 del tornillo del tope de seguridad de la platina 9 6 Gire el rev lver 12 hasta colocar el objetivo de 40x sobre el esp cimen 7 Baje el objetivo sobre el portaobjetos hasta que la punta del lente est casi encima del mismo Tenga mucho cuidado y no permita que el objetivo toque el portaobjetos Enrosque el tornillo de seguridad 9 hacia arriba hasta que se tope contra el mecanismo de enfoque 9 Haga girar la tuerca de retenci n estriada hacia arriba para trabar el tornillo de seguridad ES 10 Pinza sujetadora Nota La perilla superior de movimiento de la de la platina platina se
40. clockwise 5 Unthread the safety rack stop screw 9 about 2 3 of the way 6 Turn the nosepiece 12 until the 40x lens is over the specimen 7 Lower the objective lens over the slide until the tip of the lens is slightly above the specimen slide Be careful not to touch the objective lens to the slide Thread the safety screw 9 upward until it stops against the focus mechanism 9 Rotate the knurled locking nut upward to lock the safety screw in place 2 Abbe Condenser Iris Diaphragm Stage Movement Knobs Figure 4g Figure 4h Tip To position the specimen directly under the objective lens close the opening on the iris diaphragm see Figure 4h until it is almost completely closed You should see a small beam of light projected onto the specimen slide Now simply use the stage movement knobs to move the specimen directly inside the beam of light 10 Use the nosepiece 12 to rotate the objective lenses 4 until the 4x objective is directly over the specimen Always start with the lowest power objective and work your way up to higher powers 11 Look through the eyepiece while turning the coarse focus knob 3 until the specimen comes into view You may need to adjust the stage knobs Figure 4h slightly to center the specimen in the field of view Warning When focusing be careful not to raise the specimen stage so high that the specimen slide touches the objective lens Not only can you break your slide but you may scra
41. croscopio en la luz solar directa para evitar da ar el microscopio o la vista Cuando mueva el microscopio suj telo del brazo con una mano y no de las perillas de enfoque alojamiento del ocular etc Coloque la otra mano debajo de la base para sostenerlo Limpie las superficies exteriores met licas y pl sticas con un pa o h medo Siempre desenchufe el cord n el ctrico antes de limpiar Nunca limpie las superficies pticas con una toalla de tela o toalla de papel ya que podr a rayarlas f cilmente Sople el polvo acumulado en las superficies pticas con un pincel de pelo de camello o con un soplador de aire Para limpiar las impresiones digitales de las superficies pticas use un agente para limpiar lentes y papel para lentes que se venden en la mayor a de las tiendas de fotograf a Cuando limpie no frote en c rculo ya que puede rayar el lente Nunca desarme o limpie las superficies pticas internas Esto debe ser hecho por un t cnico capacitado en la f brica u otros centros de reparaci n autorizados Cuando use portaobjetos de vidrio tenga cuidado ya que los bordes pueden ser filosos 18 Garant a de dos a os de Celestron A Celestron garantiza este microscopio libre de defectos de materiales y mano de obra por un per odo de dos a os Celestron reparar o reemplazar el producto o parte del mismo si una vez inspeccionado por Celestron se demuestra que los materiales o la mano de obra son defectuosos Como condi
42. d repair Further product malfunction or deterioration due to normal wear is not covered by this warranty CELESTRON DISCLAIMS ANY WARRANTIES EXPRESS OR IMPLIED WHETHER OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR USE EXCEPT AS EXPRESSLY SET FORTH HEREIN THE SOLE OBLIGATION OF CELESTRON UNDER THIS LIMITED WARRANTY SHALL BE TO REPAIR OR REPLACE THE COVERED PRODUCT IN ACCORDANCE WITH THE TERMS SET FORTH HEREIN CELESTRON EXPRESSLY DISCLAIMS ANY LOST PROFITS GENERAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT FROM BREACH OF ANY WARRANTY OR ARISING OUT OF THE USE OR INABILITY TO USE ANY CELESTRON PRODUCT ANY WARRANTIES WHICH ARE IMPLIED AND WHICH CANNOT BE DISCLAIMED SHALL BE LIMITED IN DURATION TO A TERM OF TWO YEARS FROM THE DATE OF ORIGINAL RETAIL PURCHASE Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Celestron reserves the right to modify or discontinue without prior notice to you any model or style microscope If warranty problems arise or if you need assistance in using your microscope contact Celestron Technical Support Department 2835 Columbia Street Torrance CA 90503 U S A Tel 310 328 9560 Fax 310 212 5835 www celestron com Monda
43. derecho de modificar o discontinuar sin previo aviso cualquier modelo o estilo de microscopio En el caso de surgir problemas cubiertos por la garant a o de necesitar asistencia para el uso del microscopio s rvase ponerse en contacto con Celestron Technical Support Department 2835 Columbia Street Torrance CA 90503 EE UU Tel 310 328 9560 Fax 310 212 5835 www celestron com Lunes a viernes de 8 00 a m a 4 00 p m hora del Pac fico Esta garant a reemplaza todas las garant as del producto anteriores NOTA Esta garant a es v lida para los clientes de EE UU y Canad que hayan comprado este producto de un Concesionario de Celestron Autorizado en EE UU o Canad La garant a fuera de EE UU y Canad es v lida nicamente para aquellos clientes que hayan comprado el producto de un Distribuidor de Celestron o de un Concesionario de Celestron Autorizado en dicho pa s y deber n ponerse en contacto con ellos para cualquier servicio cubierto por la garant a 19 A CELESTRON MANUEL DE L UTILISATEUR e Modele de laboratoire n 44100 e Modele de laboratoire n 44102 e Modele perfectionn n 44104 Modele perfectionn n 44106 Table des mati res Introduction ae 2 Modele de laboratoire n 44100 NEEN Een 3 Modele de laboratoire n 44102 sscossccssccssscosscossccosscosssesssesoseecsseco O Modele perfectionn n 44104 c ssosscescessosscescossossccevosovescesovesc
44. diodo luminiscente Figura 4d Figura 4e Figura 4f Para instalar las tres pilas AA 1 LI o Uh ee Coloque de lado el microscopio Con un destornillador Phillips de cabeza peque a quite las cuatro tornillos de las patas de goma de la parte inferior de la base para quitar entonces la cobertura de proteccion ver la Figura 4d Quite los dos tornillos Phillips brillantes que sujetan un soporte que mantiene las caja de las pilas en su lugar ver la Figura 4e Deslice la tapa para abrir la caja de las pilas Instale tres pilas AA seg n los indicadores de y Cierre la caja de las pilas Vuelva a colocar el soporte que sujeta a la caja de las pilas en su lugar con los dos tornillos Phillips brillantes Vuelva a colocar la cobertura de protecci n con los cuatro tornillos Phillips de las patas de goma 6e 99 ver la Figura 4f 15 Observaci n del esp cimen El instrumento cuenta con una platina mec nica con una pinza sujetadora de la platina y perillas direccionales ver las Figuras 4g y 4h La escala Vernier en ambos ejes permite marcar y duplicar exactamente la ubicaci n de un objeto en caso de que el usuario desee volver al mismo campo de visi n 1 Use la palanca para abrir el brazo de sujeci n de la pinza sujetadora de la platina 2 Coloque un portaobjetos de 3 pulgadas adentro del sujetador y cierre suavemente el brazo de sujeci n contra el portaobjetos 3 Use las perillas de movimie
45. e observaci n deseado Uso del iluminador el ctrico I 1 Sr N ii 6 R gt i 4 le Figura 3a Figura 3b Figura 3c Figura 3d Para una luz m s directa e intensa use el iluminador el ctrico suministrado Para instalar el iluminador el ctrico 1 Tire hacia afuera el espejo luminoso para sacarlo de su sost n Sale f cilmente con poca presi n ver la Figura 3a Instale el iluminador el ctrico en el mismo sost n del espejo luminoso ver la Figura 3a 2 Aseg rese de que la parte de vidrio del iluminador el ctrico ver la Figura 3b est mirando hacia arriba hacia la platina 5 3 Coloque el pasador y las presillas sobre el sost n y empuje hasta que est bien colocado ver la Figura 3c 4 Enchufe el cord n el ctrico del iluminador en un tomacorriente de CA ver la Figura 3d Cambio de los oculares El microscopio viene con oculares de 10x y 12 5x f ciles de cambiar 1 Quite cualquiera de los oculares 1 del tubo del ocular 2 tir ndolo hacia arriba 2 Instale el ocular deseado 1 en el tubo del ocular 2 empujando hacia abajo 3 Los oculares se mantienen en su sitio por fricci n Observaci n del esp cimen El instrumento cuenta con una platina mec nica con una pinza sujetadora de la platina y perillas direccionales ver la Figura 3e 1 Use la palanca para abrir el brazo de sujeci n de la pinza sujetadora de la platina 2 Coloque un portaobjetos de 3 pulgadas adentro del sujetador y
46. e Lens 5 Specimen Stage 6 Illumination Mirror CELESTRON _ 7 Base Figure 3 Standard Accessories with pour Microscope 12 5 Huygens Eyepiece Electric Illuminator Blue Filter 4x Objective Lens 5 Prepared Slides 10x Objective Lens Dust Cover 40x Objective Lens Specifications Model 44104 Specifications Stage Mechanical Stage 115mm x 125mm Arm Angle choice from 0 to 60 Focuser Coarse and Fine focus knobs Rack amp Pinion Safety Stop Objectives Achromatic 4x 10x 40x Illuminator 50mm Plano Concave Mirror Eyepieces 10mm 12mm Field of View 12 5mm 10mm Field of View Nosepiece Triple with click stop Condenser Abbe N A 1 25 Diaphragm Iris Magnification Table Use the following table to determine the magnification of the different eyepiece objective lens combination of your microscope Objective Lens 4x 10x 40x 10x Eyepiece 40x 100x 400x 12 5x Eyepiece 50x 125x 500x Setting Up Dour Microscope Take the Styrofoam container out of the cardboard carton Remove the tape from the Styrofoam container holding the two sections together Carefully remove the microscope and other parts from the container and set them on a table desk or other flat surface Remove the plastic bag covering the microscope Remove the protective paper from the stage 5 Remove the plastic cap from the eyepiece tube 2
47. e au point de l chantillon 1 Commencez toujours avec la plus basse puissance objectif 4x et basculez sur une puissance sup rieure en tournant la tourelle 12 sur les objectifs 10x puis 40x Veillez ne pas laisser l objectif toucher la lame porte objets en passant un grossissement plus lev Utilisez le bouton de mise au point fine 11 pour changer la profondeur de champ et obtenir une mise au point pr cise de l chantillon que vous observez Si le trajet descendant est insuffisant pour obtenir une mise au point nette vous pouvez d vissez la vis de s curit 9 pour augmenter le trajet vers le bas Une fois encore vitez tout contact entre l objectif et la lame porte objets Microscope perfectionn Mod le n 44104 10 Potence 11 Bouton de mise au point fine 9 But e de s curit de la cr maill re 8 Pince valet de la platine 1 Oculaire 2 Tube de l oculaire 3 Bouton de mise au point grossi re 12 Tourelle 4 Obiectif 5 Platine chantillons 6 Miroir illuminateur CELESTRON 7 Socle Figure 3 Accessoires standard libres avec botre microscope e Oculaire de Huygens 10x e Oculaire de Huygens 12 5 e Filtre bleu e Illuminateur lectrique e Objectif 4x e Objectif 40x e Objectif 10x e House de protection e 5 lames porte objets pr par es Modele n 44104 Sperifications Specifications Platine
48. e compartiment alignez le trou filet sur la vis de serrage et serrez la en tournant dans le sens horaire Microscope perfectionn Mod le n 44106 1 Oculaire uw 2 Tube de l oculaire 2 I 14 T te 12 Tourelle y 4 Obiectif 10 Potence A 9 But e de s curit de la cr maill re 5 Platine 8 Pince valet de la platine S chantillons 6 Illuminateur LED 6 13 Interrupteur On Off Marche Arr t 3 Bouton de mise au point grossi re 11 Bouton de mise au point fine A CELESTRON AAA 7 Socle Figure 4 Accessoires standard livr s aber votre microscope e Oculaire 10x avec pointeur e Illuminateur LED e Objectif 4x e Filtres vert jaune bleu e Objectif 10x e Huile immersion e Objectif 40x e 5 lames porte objets pr par es e Objectif 100x e House de protection Sperifications Modele n 44106 Specifications Platine Platine mecanique 115 mm x 125 mm T te Monoculaire avec inclinaison de 45 et rotation sur 360 Boutons de mise au point grossi re et fine cr maill re et Dispositif de mise au point pignon avec but e de s curit Objectifs Achromatique 4x puissance 40 10x puissance 100 40x puissance 400 100x puissance 1000 llluminateur Miroir plan et concave de 50 mm Large champ de vision avec pointeur 10x Champ de vision Oculaire 18 mm Tourelle Quadruple avec but e a d clic Condense
49. e el esp cimen con una pieza de vidrio delgado y coloque el aceite sobre la cubierta de vidrio No coloque el aceite directamente sobre el esp cimen 16 Ajuste de la luz Los espec menes de diferentes tama os espesores y variaciones de colores requieren diferentes niveles de iluminaci n Existen tres maneras de cambiar la cantidad de luz cuando se observa un esp cimen ajustar el control de intensidad con la perilla de encendido y apagado on off 13 ajustar el condensador Abbe Figura 4g y ajustar el diafragma iris ver la Figura 4h 1 Cuando observe un esp cimen de color oscuro o no transparente necesitar aumentar la cantidad de luz para resolver ciertas caracter sticas o detalles Esto se hace f cilmente aumentando la intensidad del iluminador LED diodo luminiscente haciendo girar el control de intensidad del interruptor de encendido y apagado on off 13 a su posici n m s alta 2 Cuando se realiza la observaci n con objetivos de menor aumento de 4x y 10x debe bajar el lente del condensador para dispersar la luz sobre el campo de visi n m s amplio Para cambiar la posici n del condensador haga girar la porci n plateada del centro del diafragma iris 4h en el sentido de las agujas del reloj hasta que el haz de luz se disperse lo suficiente para iluminar el campo de visi n completo 3 Laimagen aparecer menos iluminada cuando baje el condensador para dispersar la luz o cuando cambie a un objetivo de m s aumento
50. e vous abaissez le condenseur pour r partir l clairage ou que vous passez des objectifs plus puissants l image apparait plus floue Ouvrez l ouverture du diaphragme iris pour faire p n trer davantage de lumi re L ouverture et la fermeture du diaphragme donnent une vue en relief de l chantillon et vous permettent de changer la profondeur de champ de l chantillon observ Utilisation d un filtre Pour faire ressortir diff rents niveaux de d tails exp rimentez en changeant la couleur de l clairage de fond de l chantillon Pour changer la couleur de l clairage placez le filtre bleu dans la trajectoire de la lumi re en l installant sur la partie sup rieure de l illuminateur lectrique Il peut tre n cessaire de refaire une mise au point en r glant l g rement le bouton de mise au point fine 11 pour une meilleure qualit d observation Replacing the Electric Illuminator Bulb Pour remplacer une ampoule grill e proc dez ES LIE Vis de serrage Figure 3g 12 comme suit 1 Retirez la vis de serrage de Villuminateur en la tournant dans le sens antihoraire Ouvrez le compartiment o se trouve l ampoule au tungst ne de 20 watts Retirez l ampoule en l enfon ant l g rement et en la tournant dans le sens horaire pour la sortir Prenez la nouvelle ampoule et alignez ses broches sur les encoches de la douille puis enfoncez la et tournez la dans le sens horaire en position ClRefermez l
51. efermez d licatement le bras de serrage contre la lame porte objets 3 Utilisez les boutons de d placement de la platine voir Figure 3e pour positionner l chantillon sur l ouverture de la platine 5 Vous pouvez maintenant faire une mise au point et observer l chantillon mais vous devez n anmoins prendre certaines pr cautions pour ne pas endommager la lame porte objets ou l objectif Votre microscope est quip d une but e de s curit 9 qui vous permet de r gler le trajet de la cr maill re sur le dispositif de mise au point Cette but e est destin e viter tout contact accidentel de l objectif et de la lame porte objets afin de ne pas briser la lame ou de rayer l objectif Pour r gler le trajet sur le m canisme de mise au point 4 Relevez l objectif en tournant le bouton de mise au point 3 vers l arri re sens horaire pour l loigner de la platine 5 5 D vissez la vis d arr t 9 de la but e de s curit de la cr maill re sur environ 2 3 de la longueur Tournez la tourelle 12 jusqu ce que l objectif 40x soit au dessus de l chantillon 7 Abaissez l objectif sur la lame porte objets jusqu ce que l extr mit de l objectif se trouve l g rement au dessus de la lame Veillez ne pas toucher la lame porte objets avec l objectif 8 Vissez la vis de s curit 9 vers le haut jusqu ce qu elle butte contre le m canisme de mise au point 9 Tournez le contre crou molet vers le haut pour bloquer l
52. einer Probe Ihr Mikroskop ist mit einem mechanischen Objekttisch mit einer Objekttisch Halteklemme und Richtungskn pfen ausgestattet Siehe Abb 4g und 4h Eine Vernier Skala auf beiden Achsen erm glicht die genaue Markierung und Replikation eines Objekts im Sichtfeld zu dem der Benutzer sp ter eventuell zur ckkommen m chte 1 ffnen Sie den Klemmarm der Objekttisch Halteklemme mit dem Klemmenhebel 2 Setzen Sie einen Objekttr ger 3 Zoll 7 62 cm Gr e im Halter ein und schlie en Sie den Klemmarm vorsichtig am Objekttr ger 3 Mit den Objekttischkn pfen siehe Abb 4h k nnen Sie die Probe ber der ffnung im Objekttisch 5 positionieren Jetzt k nnen Sie das Mikroskop scharf einstellen und die Probe betrachten aber zuerst m ssen Sie noch einige VorsichtsmaBnahmen ergreifen damit der Objekttr ger oder die Objektivlinse nicht besch digt werden Ihr Mikroskop ist mit einem Anschlagschutz 9 versehen der die Regulierung des Bewegungsbereichs am Fokussierer erm glicht Damit wird sichergestellt dass die Objektivlinse nicht versehentlich mit dem Objekttr ger in Kontakt kommt denn dabei konnte der Objekttr ger zerbrochen oder die Objektivlinse zerkratzt werden Einstellung des Bewegungsbereichs am Fokusmechanismus 4 Heben Sie die Objektivlinse vom Objekttisch 5 ab indem Sie den Grobtriebknopf 3 nach hinten drehen im Uhrzeigersinn 5 Drehen Sie die Anschlagschutzschraube 9 ca 2 3 heraus 6 Drehen Sie den Revo
53. en eine hohe Vergr erungsleistung von 40 bis zu 1000x Diese Mikroskoptypen sind ideal f r die Untersuchung von Objekttr gern mit Hefe und Schimmelpilzproben Kulturen Pflanzen und Tierproben Fasern Bakterien etc geeignet Der abschlie ende Abschnitt enth lt einfache Pflege und Wartungstipps Befolgen Sie diese um eine jahrelange Qualit tsleistung und Nutzung sicherzustellen damit Sie lange Freude an Ihrem Mikroskop haben Labormikroskop Modell 44100 1 Okular 2 Okulartubus 10 Arm 3 Fokussierknopf 9 Anschlagschutz 4 Objektivlinse i 5 Objekttisch 8 Gefederte jekttisc Objekttischklemmen N N 6 Beleuchtungsspiegel amp CELESTRON 7 gun Abb 1 Im Lieferumfang des Mikroskops enthaltenes Standardsubehvor e 10x Huygens Okular e 5 fertige Objekttr ger e 20x Objektivlinse 200x mit Okular e Staubschutz Technische Baten Modell 44100 Technische Daten Objekttisch Einfacher Objekttisch mit Federklemmen 88 mm x 88 mm Arm Winkelbereich 0 bis 45 Fokussierer Grobtrieb Rack und Pinion mit Anschlagschutz Objektiv Achromatisch 20x Beleuchtung Plankonkaver Spiegel 42 mm Okular 10x 12 mm Sichtfeld Aufbau des Mikroskops 1 Nehmen Sie den Styroporbeh lter aus dem Karton 2 Entfernen Sie das Klebeband vom Styroporbeh lter mit dem die beiden Teile zusammengehalten werden 3 Nehmen Sie das Mikroskop und die anderen Teile vor
54. en the aperture of the iris diaphragm to let in more light Opening and closing the diaphragm will give a relief view of the specimen and allow you to change the depth of field of the specimen being viewed Using a Filter To bring out different levels of detail experiment with changing the color of the back lighting of the specimen To change the lighting color place the blue filter in the light path by placing it on the top of the electric illuminator You may need to refocus by adjusting the fine focus knob 11 slightly for best viewing Replacing the Electric Hluminator Bulb To replace a burned out bulb do the following pu ro Thumbscrew Figure 3g 12 1 Take out the thumbscrew on the illuminator by turning it counter clockwise Open the compartment and you will see the 20 watt tungsten bulb Remove the bulb by pressing lightly down on the bulb and rotate it counter clockwise and it will come out Take the new bulb and line up the pins of the bulb with the slots in the bulb socket and then push it down and rotate clockwise until it sets in place Close the compartment line up the threaded hole for the thumbscrew and tighten it by turning clockwise Advanced 1 Eyepiece 2 Eyepiece Tube 10 Arm E 9 Safety Rack Stop 8 Stage Holder Clamp 3 Coarse Focus Knob 11 Fine Focus Knob Microscope Model 44106 3 5 14 Head 12 Nosepiece 5 Nu 4 Objective Lens 5
55. erre la abertura del diafragma iris ver la Figura 4h hasta que est casi completamente cerrado Podr ver un peque o haz de luz que se proyecta sobre el portaobjetos Ahora simplemente use las perillas de movimiento de la platina para mover el esp cimen directamente dentro del haz de luz 10 Use el rev lver 12 para girar los objetivos 4 hasta que el objetivo de 4x quede directamente sobre el esp cimen Comience siempre son el objetivo de menor aumento y contin e subiendo el aumento 11 Mire a trav s del ocular al mismo tiempo que gira la perilla macrom trica 3 hasta que el esp cimen quede a la vista Si necesita centrar el esp cimen en el campo de visi n mueva levemente las perillas de la platina Figura 4h Advertencia Cuando enfoque cuide de no levantar la platina demasiado de manera que el portaobjetos toque el objetivo No solo podr a romper el portaobjetos sino que tambi n puede rayar el objetivo 12 Por ltimo ajuste la perilla microm trica 11 hasta alcanzar el enfoque m s n tido posible para su vista Advertencia Nunca haga girar las perillas microm tricas en direcci n opuesta al mismo tiempo ya que podr a da ar el mecanismo de enfoque Sugerencia Cuando observe un esp cimen con el objetivo de 100x puede mejorar el aumento de la resoluci n colocando una peque a gota de aceite de inmersi n entre el esp cimen y el objetivo Para los portaobjetos de los espec menes que prepara usted mismo cubra siempr
56. erzielen l sst k nnen Sie die Anschlagschutzschraube 9 losschrauben um eine weitere Bewegung nach unten zu erm glichen Es wird nochmals daran erinnert dass die Objektivlinse nicht den Objekttr ger ber hren darf Erweitertes Advanced Mikroskop Modell 44104 1 Okular 2 Okulartubus 3 Grobtriebknopf 10 Arm 12 Objektivwechselrevolver 11 Feintriebknopf 4 Objektivlinse 9 Anschlagschutz 5 Objekttisch 8 Objekttisch Halteklemme 6 Beleuchtungsspiegel CELESTRON 7 Fu Abb 3 Im Lieferumfang des Mikroskops enthaltenes Standardsubehor e 10x Huygens Okular e Elektrische Beleuchtung e 12 5 Huygens Okular e Blaufilter e 4x Objektivlinse e 5 fertige Objekttr ger e 10x Objektivlinse e Staubschutz e 40x Objektivlinse Technische Daten Modell 44104 Technische Daten Objekttisch Mechanischer Objekttisch 115 mm x 125 mm Arm Winkelbereich 0 bis 60 Fokussierer Grob und Feintriebkn pfe Rack und Pinion Anschlagschutz Objektive Achromatisch 4x 10x 40x Beleuchtung Plankonkaver Spiegel 50 mm Okulare 10 mm 12 mm Sichtfeld 12 5 mm 10 mm Sichtfeld Objektivwechselrevolver Dreifach mit Klickstopp Kondensor Abbe N A 1 25 Diaphragma Blende Irisblende Vergroperungstabelle Anhand der folgenden Tabelle konnen Sie die VergroBerung der verschiedenen Okular Objektivlinsen Kombinationen Ihres Mikroskops ermittel
57. esesseess Mod le perfectionn n 44106 ENEE nen 13 Nettoyage et entretien NENNEN otto onn unu nnno horn un KEEN KEN NN preuves e ee eese Kee S Garanti id H Introduction Nous vous f licitons d avoir fait l acquisition d un microscope Celestron Votre microscope est un instrument de pr cision optique fabriqu partir de mat riaux de la meilleure qualit pour lui assurer une grande durabilit et long vit Il est congu pour vous donner une vie enti re de satisfaction avec un entretien minimum Ce manuel de l utilisateur concerne quatre mod les de microscope Veuillez utiliser le num ro correspondant votre mod le de microscope pour lire les informations qui s y rapportent Avant de tenter d utiliser votre microscope veuillez lire attentivement le mode d emploi afin de vous familiariser avec ses diff rentes fonctions et son mode op rationnel et d en profiter ainsi pleinement Reportez vous aux sch mas du microscope pour tudier les diff rentes pi ces dont il est question dans ce manuel Les microscopes d crits dans ce manuel disposent de puissances de grossissement lev es allant de 40 1000x Ces types de microscopes conviennent parfaitement l observation d chantillons de levures et de moisissures de cultures d l ments v g taux et animaux ainsi que de fibres bact ries et autres plac s sur des lames porte objets La derni re partie de ce manuel offre des conseils de nettoyage et d e
58. from the specimen stage 5 by rotating the coarse focus knob 3 backwards clockwise 5 Unthread the safety rack stop screw 9 about 2 3 of the way 6 Turn the nosepiece 12 until the 40x lens is over the specimen 7 Lower the objective lens over the slide until the tip of the lens is slightly above the specimen slide Be careful not to touch the objective lens to the slide Thread the safety screw 9 upward until it stops against the focus mechanism 9 Rotate the knurled locking nut upward to lock the safety screw in place 10 Stage Holder Note The top stage movement knob moves in the X Clamp axis forward and backward whereas the bottom stage movement knob moves in the Y axis side to side A vernier scale on both axes allows the exact marking and replication of an object in the field of view that the user may want to Stage Movement come back to Knobs Figure 3e Tip To position the specimen directly under the objective lens close the opening on the iris diaphragm see Figure 3f until it is almost completely closed You should see a small beam of light projected onto the specimen slide Now simply use the stage movement knobs to move the specimen directly inside the beam of light 10 Use the nosepiece 12 to rotate the objective lenses 4 until the 4x objective is directly over the specimen Always start with the lowest power objective and work your way up to higher powers 11 Look through the eyepiece while
59. g Loaded Stage Clips 4 Objective Lens 5 Specimen Stage as 6 Illumination Mirror a K Q CELESTRON 7 Base Figure 2 Standard Accessories with pour Microscope e 10x Huygens Eyepiece e 40x Objective Lens e 4x Objective Lens e 5 Prepared Slides e 10x Objective Lens e Dust Cover Specifications Model 44102 Specifications Stage Plain Stage with spring loaded clips 120mm x 110mm Arm Angle choice from 0 to 60 Focuser Coarse and Fine focus knobs Rack and Pinion Safety Stop Objectives Achromatic 4x 40 power 10x 100 power 40x 400 power Illuminator 50mm Plano Concave Mirror Eyepiece 10x 12mm Field of View Nosepiece Triple with click stop Condenser N A 0 65 Diaphragm Disc Diaphragm with five aperture sizes Setting Up Pour Microscope 1 Take the Styrofoam container out of the cardboard carton 2 Remove the tape from the Styrofoam container holding the two sections together 3 Carefully remove the microscope and other parts from the container and set them on a table desk or other flat surface 4 Remove the plastic bag covering the microscope 5 Remove the protective paper from the stage 5 6 Remove the plastic cap from the eyepiece tube 2 7 Insert the 10x eyepiece in the eyepiece tube 2 8 Remove the three objective lenses 4 from their containers Unscrew the container lids from the threaded po
60. g der Beleuchtung Einstellung des Armwinkels Die normale Betrachtungsposition ist bei 0 Es sind aber auch andere Betrachtungswinkel von 0 bis 60 m glich Anderung des Betrachtungswinkels 1 Halten Sie den Mikroskopfu 7 mit einer Hand fest 2 Neigen Sie dann mit der anderen Hand den Arm 10 indem Sie ihn nach hinten oder vorn in den gew nschten Betrachtungswinkel ziehen Verwendung der elektrischen Beleuchtung Abb 3b Abb 3c Abb 3d F r eine direktere und intensivere Beleuchtung sollten Sie die im Lieferumfang enthaltene elektrische Beleuchtung verwenden Installation der elektrischen Beleuchtung 1 Entfernen Sie die Spiegelbeleuchtung indem Sie sie aus der H lle herausziehen Sie l sst sich ohne gro e Druckanwendung entfernen Siehe Abb 3a Die elektrische Beleuchtung wird in der H lle aus der die Spiegelbeleuchtung entfernt wurde installiert Siehe Abb 3a Achten Sie darauf dass das Glasteil der elektrischen Beleuchtung siehe Abb 3b nach oben zum Objekttisch 5 gerichtet ist Platzieren Sie die Stifte und Klemmen der Beleuchtung ber der H lle und dr cken Sie sie vollst ndig ein Siehe Abb 3c SchlieBen Sie das Kabel der elektrischen Beleuchtung an einer geeigneten Wechselstromquelle an siehe Abb 3d ADD Okular Austausch Ihr Mikroskop wird mit 10x und 12 5x Okularen geliefert Sie lassen sich leicht auswechseln Entfernen Sie das Okular 1 vom Okulartubus 2 indem Sie es nach
61. icht Zimmerbeleuchtung Lampe etc auf den Objekttisch reflektiert Der Spiegel weist eine flache Seite Ihr Spiegelbild ist auf der flachen Oberfl che leicht zu sehen und eine konkave Seite auf Die konkave Seite konzentriert mehr Licht auf die Probe als die flache Seite Beleuchtung einer Probe 1 Bei Tageslicht Neigen Sie den Spiegel 6 so dass indirektes Sonnenlicht durch die Unterseite des Objekttisches reflektiert wird 5 Achtung Niemals mithilfe des Spiegels direktes Sonnenlicht durch das Mikroskop richten Das kann sehr gef hrlich sein und Ihre Augen k nnen Schaden davontragen Bei Betrachtung nachts oder in Innenr umen ohne Sonneneinstrahlung k nnen Sie eine Schreibtisch oder Tischlampe oder andere Lichtquelle verwenden um Licht auf eine Probe zu reflektieren Regulierung der auf die Probe reflektierten Lichtmenge 1 Mit der konkaven Seite des Spiegels k nnen Sie mehr Licht auf den Objekttr ger fokussieren Die konkave Seite konzentriert mehr Licht auf Ihre Probe aber sie fokussiert einen kleineren Lichtstrahl der empfindlicher auf Einstellung reagiert Wenn Sie den Spiegel nicht so einstellen k nnen dass die Probe ausreichend beleuchtet wird k nnen Sie auch den Arm 10 nach hinten neigen um die Position des Spiegels zu ndern Siehe Abschnitt Einstellung des Armwinkels Sie k nnen auch die Lichteinstellung mit dem Kondensor und dem Diaphragma Blende regulieren Siehe Abschnitt Einstellun
62. icht im Lieferumfang enthalten betrieben 1 2 3 4 5 Entfernen Sie die Spiegelbeleuchtung indem Sie sie aus der H lle herausziehen Der Tubus der LED Leuchte wird gegen den Uhrzeigersinn ber den LEDs im FuB des Mikroskops eingeschraubt siehe Abb 4a Drehen Sie den Tubus von Hand fest Siehe Abb 4b Legen Sie die Batterien ein siehe n chster Abschnitt unten Nach dem Einlegen der Batterien schalten Sie den Netzschalter 13 ein Achten Sie darauf dass der Schalter auf der R ckseite des Mikroskopfu es in der Btry Position ist Siehe Abb 4c Einlegen der Batterien f r die LED Leuchte Abb 4d Abb 4e Abb 4f Einlegen der drei AA Batterien 1 2 LI sat Legen Sie das Mikroskop auf die Seite Entfernen Sie mit einem kleinen Kreuzschlitzschraubendreher die vier Schrauben Gummif e unten am Fu Daraufhin l sst sich die Blende abnehmen Siehe Abb 4d Entfernen Sie die beiden gl nzenden Kreuzschlitzschrauben mit denen die Halterung f r das Batteriefach befestigt ist Siehe Abb 4e Schieben Sie das Batteriefach auf Legen Sie drei AA Batterien entsprechend den und Markierungen ein Siehe Abb 4f SchlieBen Sie das Batteriefach Legen Sie die Halterung des Batteriefachs wieder an und sichern Sie sie mit den beiden gl nzenden Kreuzschlitzschrauben Legen Sie die Blende mit den vier Kreuzschlitzschrauben Gummif fen wieder an 15 Betrachtung
63. ide open the battery box Install three AA batteries following the and indicators see Figure 4f Close the battery box Replace the bracket holding the battery box in place with the two shiny Phillips head screws Replace the screen with the four Phillips head screws rubber feet ANNE 15 Viewing a Specimen Your instrument is provided with a mechanical stage with a stage holder clamp and directional knobs see figure 4g and 4h A vernier scale on both axes allows the exact marking and replication of an object in the field of view that the user may want to come back to 1 Use the clamp lever to open the clamping arm of the stage holder clamp 2 Place a specimen slide 3 size inside the holder and gently close the clamping arm against the slide 3 Use the stage movement knobs see Figure 4h to position the specimen over the opening in the stage 5 You are now ready to focus and view the specimen but first you must take some precautions so as not to damage the specimen slide or objective lens Your microscope is equipped with a safety rack stop 9 which allows you to regulate the range of travel on the focuser This assures that the objective lens will not accidentally come into contact with the specimen slide breaking the slide or scratching the objective lens To adjust the travel on the focus mechanism 4 Raise the objective lens away from the specimen stage 5 by rotating the coarse focus knob 3 backwards
64. ie h chste Einstellung 2 Bei der Betrachtung mit Objektivlinsen kleinerer Vergr erung 4x und 10x m ssen Sie die Kondensorlinse absenken um das Licht ber das gr fere Sichtfeld zu verteilen Zur nderung der Position des Kondensors drehen Sie einfach den silbernen Mittelteil der Irisblende 4h im Uhrzeigersinn bis der Lichtstrahl sich weit genug ausbreitet um das gesamte Sichtfeld bei der Betrachtung zu beleuchten 3 W hrend Sie den Kondensor absenken um das Licht auszubreiten oder zu einer Objektivlinse mit gr erer Vergr erung wechseln erscheint das Bild abgedunkelt Anstatt die Lichthelligkeit der Leuchte zu erh hen was zur Auswaschung von feinen Details der untersuchten Probe f hren kann k nnen Sie auch die Apertur der Irisblende ffnen um mehr Licht hereinzulassen ffnen und Schlie en der Blende erm glicht eine Reliefansicht der Probe und erm glicht die Anderung der Sch rfentiefe der betrachteten Probe Verwendung von Filtern Um verschiedene Detailstufen darzustellen k nnen Sie mit einer Anderung der Farbe der Hintergrundbeleuchtung der Probe experimentieren Zur nderung der Lichtfarbe setzen Sie den Blaufilter Gr nfilter oder Gelbfilter im Lichtpfad ein indem Sie ihn oben auf die LED Leuchte aufsetzen Es kann sein dass Sie neu fokussieren m ssen indem Sie den Feintriebknopf 11 leicht justieren um ein optimales Bild zu erhalten Experimentieren Sie mit den einzelnen Farben um das Ergebni
65. iew To change the position of the condenser simply rotate the silver center portion of the Iris diaphragm 4h clockwise until the beam of light spreads wide enough to illuminate the entire field of view when viewing 3 As you lower the condenser to spread out the light or change to a higher power objective lens your image will appear dimmer Instead of increasing the light intensity of the illuminator which may wash out fine detail of the specimen you are viewing open the aperture of the iris diaphragm to let in more light Opening and closing the diaphragm will give a relief view of the specimen and allow you to change the depth of field of the specimen being viewed Using Filters To bring out different levels of detail experiment with changing the color of the back lighting of the specimen To change the lighting color place the blue filter the green filter or the yellow filter in the light path by placing one on top of the LED illuminator You may need to refocus by adjusting the fine focus knob 11 slightly for best viewing You should experiment with each of the colors to see the results 17 Care and Maintenance Your Celestron microscope is a precision optical instrument and should be treated with care at all times Follow these care and maintenance suggestions and your microscope will need very little maintenance throughout its lifetime When you are done using your microscope remove any specimens left on the stage Turn
66. ight reflecting onto the specimen 1 Use the concave side of the mirror to focus more light on the slide The concave side will concentrate more light onto your specimen but will focus a smaller beam of light making it more sensitive to adjust 2 If you are unable to adjust the mirror enough to properly illuminate the specimen you can also tilt the arm 10 backward to change the position of the mirror see the section under Adjusting the Arm Angle 3 You can also control light adjustment with the condenser and diaphragm see the section under Adjusting the Lighting Adjusting the Arm Angle The normal viewing position is at 0 However you can view at any angle from 0 to 60 To change the viewing angle 1 With one hand hold the base 7 2 Then with your other hand tilt the arm 10 by pulling it backward or forward to the desired viewing angle Using the Electric Illuminator 0 ee ili 6 LA Y q y Figure 3a Figure 3b Figure 3c Figure 3d For more direct and intensive light you should use the supplied electric illuminator To install the electric illuminator 1 Remove the mirror illuminator by pulling it outward from its sleeve It will come out very easily with little pressure see Figure 3a 2 You will install the electric illuminator in the sleeve you removed the mirror illuminator from see Figure 3a 3 Besure the glass part of the electric illuminator see Figure 3b is facing up towards the st
67. ir la lumi re sur un chantillon 1 Pour contr ler la quantit de lumi re r fl chie sur l chantillon Utilisez la face concave du miroir pour faire converger davantage de lumi re sur la lame porte objets La face concave permet de concentrer plus de lumi re sur votre chantillon mais le faisceau lumineux qu elle fait converger est plus troit ce qui rend son r glage plus d licat S il ne vous est pas possible de r gler le miroir de mani re clairer correctement l chantillon vous pouvez incliner la potence 10 vers l arri re pour changer la position du miroir Il est possible en outre de contr ler la quantit de lumi re en tournant le diaphragme disque 5 tailles d ouverture voir figure 2a sous la platine chantillons 5 1 2 3 Reglage de l angle de la potence La position d observation habituelle est de 0 Toutefois vous pouvez observer des chantillons en utilisant n importe quel angle compris entre 0 et 60 Pour changer l angle optique 1 2 Tenez le socle d une main 7 Ensuite avec votre autre main inclinez la potence 10 en la ramenant vers l arri re ou vers l avant sur l angle optique recherch Condenseur Diaphgragme disque Figure 2a Observation d un chantillon Placez d licatement une lame d chantillon sous les leviers ressorts de la platine 8 et centrez l chantillon directement sur l orifice situ au centre de la platine 5 Vo
68. is sie ganz eingesetzt ist SchlieBen Sie das Fach richten Sie die Gewinde ffnung f r die Daumenschraube aus und ziehen Sie sie durch Drehen im Uhrzeigersinn fest Erweitertes Advanced Mikroskop Modell 44106 1 Okular HE 2 Okulartubus 2 14 Kopf 12 Objektivwechselrevolver d NE 4 Obiektivlinse 10 Arm 9 Anschlagschutz o 5 Objekttisch 8 Objekttisch Halteklemme 6 LED Leuchte 13 Ein Aus Schalter 7 Euh 3 Grobtriebknopf 11 Feintriebknopf A CELESTRON Abb 4 Im Lieferumfang des Mikroskops enthaltenes Standardsubehor e 10x Okular mit Zeiger e LED Beleuchtun e 4x Objektivlinse e Gr n Gelb Blaufilter e 10x Objektivlinse e Immersions l e e e 40x Objektivlinse 5 fertige Objekttr ger e 100x Objektivlinse Staubschutz Technische Baten Modell 44106 Technische Daten Objekttisch Mechanischer Objekttisch 115 mm x 125 mm Kopf Monokular 45 gewinkelt und 360 drehbar Grob und Feintriebkn pfe Rack und Pinion Fokussierer Anschlagschutz Achromatisch 4x 40 Vergr Berungsleistung 10x 100 Objektive Vergr Berungsleistung 40x 400 Vergr Berungsleistung 100x 1000 Vergr Berungsleistung Beleuchtung Plankonkaver Spiegel 50 mm Okular 10x Weitfeld mit Zeiger 18 mm Sichtfeld Objektivwechselrevolver Vierfach mit Klickstopp Kondensor Abbe N A 1 25 Diaphragma Blende Irisb
69. isation de l illuminateur LED es s OCs swe a Lamp LED MAIte E nn Figure 4a Figure 4b Figure 4c Si vous souhaitez une lumi re plus directe et intense utilisez l illuminateur LED livr avec L illuminateur LED fonctionne avec trois piles AA fournies par l utilisateur 1 2 3 4 5 Retirez l illuminateur du miroir en le sortant de son tui Le tube de l illuminateur LED se visse dans le sens antihoraire sur les LED situ es sur le socle du microscope voir Figure 4a Tournez le tube jusqu ce qu il soit serr voir Figure 4b Installez les piles voir rubrique ci dessous Une fois les piles install es mettez l interrupteur 13 sur on marche Assurez vous que l interrupteur situ l arri re du microscope est sur Btry voir Figure 4c Installation des piles de l illuminateur LED Figure 4d Figure 4e Figure 4f Pour installer les trois piles AA 1 2 LI Ce rope Tournez le microscope sur le c t A l aide d un petit tournevis cruciforme retirez les quatre vis pieds en caoutchouc en bas du socle et enlevez alors la grille voir Figure 4d Retirez les deux vis cruciformes brillantes qui maintiennent le support de fixation du compartiment piles en position voir Figure 4e Ouvrez le compartiment piles Installez les trois piles AA en respectant les polarit s et voir Figure 4f Refermez le compartiment pi
70. ittel und Linsenreinigungst cher die in den meisten Fotofachgesch ften erh ltlich sind Beim Reinigen keine Kreisbewegungen machen da das zu Kratzern o f hren kann Die internen optischen Oberfl chen nicht zerlegen oder reinigen Solche Arbeiten d rfen nur von qualifizierten Technikern im Herstellungswerk oder von anderen autorisierten Reparatureinrichtungen vorgenommen werden Beim Umgang mit Objekttr gern aus Glas vorsichtig vorgehen Sie k nnen scharfe Kanten haben 18 Celestron Zwei Jahres Garantie A Celestron garantiert f r einen Zeitraum von zwei Jahren dass dieses Mikroskop frei von Material und Herstellungsfehlern ist Celestron repariert oder ersetzt ein Produkt bzw ein Bestandteil dieses Produkts wenn Celestron nach einer Pr fung feststellt dass es einen Material oder Herstellungsfehler aufweist Als Bedingung f r die Verpflichtung von Celestron zur Reparatur oder zum Ersatz eines solchen Produkts muss das Produkt zusammen mit einem f r Celestron zufriedenstellenden Kaufnachweis an Celestron eingeschickt werden B Vor der R ckgabe muss ordnungsgem eine R ckgabe Autorisierungsnummer von Celestron eingeholt werden Bitte rufen Sie Celestron unter der Nummer 1 310 328 9560 an um diese Nummer einzuholen die dann au en an der Versandverpackung vermerkt werden muss Alle R ckgaben m ssen von einer schriftlichen Erkl rung begleitet sein die den Namen die Anschrift und Telefonnummer unter der der Eigent
71. je p armado del microscopio Retire el contenedor de espuma de poliestireno de la caja de cart n Quite la cinta del contenedor de poliestireno que sujeta las dos secciones Retire cuidadosamente el microscopio y otras piezas del contenedor y col quelos sobre una mesa escritorio o cualquier otra superficie plana Retire la bolsa de pl stico que cubre el microscopio Quite el papel protector de la platina 5 Retire la tapa de pl stico del tubo del ocular 2 Inserte el ocular de 10x en el tubo del ocular 2 Retire los tres objetivos 4 de sus envases Desatornille las tapas de los envases de la porci n roscada de los objetivos 9 Enrosque el extremo del objetivo de 4 mm en uno de los agujeros del rev lver 12 apret ndolo con los dedos En caso de ser necesario baje la platina 5 haciendo girar la perilla macrom trica 3 10 Haga girar el rev lver a la pr xima abertura y enrosque cada uno de los objetivos restantes en los agujeros correspondientes Ahora est listo para usar el microscopio PUNO Qo ON ES fllanejo del microscopio Uso del espejo luminoso El microscopio cuenta con un espejo luminoso plano c ncavo incorporado que permite iluminar el esp cimen desde abajo reflejando en la platina una fuente de luz externa luz solar indirecta luz de la habitaci n l mpara etc El espejo tiene un lado plano usted puede ver su reflejo en la superficie plana y un lado c ncavo El lado c ncavo concentra mucha m s l
72. jeros del rev lver 12 apret ndolo con los dedos En caso de ser necesario baje la platina 5 haciendo girar la perilla macrom trica 3 10 Haga girar el rev lver a la pr xima abertura y enrosque cada uno de los objetivos restantes en los agujeros correspondientes Ahora est listo para usar el microscopio Sffanejo del microscopio Uso del espejo luminoso El microscopio cuenta con un espejo luminoso plano c ncavo incorporado que permite iluminar el esp cimen desde abajo reflejando en la platina una fuente de luz externa luz solar indirecta luz de la habitaci n l mpara etc El espejo tiene un lado plano usted puede ver su reflejo en la superficie plana y un lado c ncavo El lado c ncavo concentra mucha m s luz sobre el esp cimen que el lado plano Para iluminar el esp cimen 1 Si tiene luz natural incline el espejo 6 y refleje la luz indirecta desde la parte de abajo de la platina 5 Advertencia Nunca utilice el espejo para concentrar la luz solar directa a trav s del microscopio ya que puede ser muy da ina y da ar la vista 2 Si se utiliza en la noche o adentro sin luz solar puede usar una l mpara de escritorio cercana una l mpara de mesa u otra fuente luminosa para reflejar la luz sobre el esp cimen Para controlar la cantidad de luz que se refleja en el esp cimen 1 Use el lado c ncavo del espejo para concentrar m s luz en el portaobjetos El lado c ncavo concentrar m s luz en el esp cimen
73. knob 3 backwards clockwise 2 Unthread the safety rack stop screw 9 about 2 3 of the way 3 Turn the nosepiece 12 until the 40x lens is over the specimen 4 Lower the objective lens over the slide until the tip of the lens is slightly above the specimen slide Be careful not to touch the objective lens to the slide 5 Thread the safety screw 9 upward until it stops against the focus mechanism 6 Rotate the knurled locking nut upward to lock the safety screw in place Focusing Now that the specimen slide is placed directly under the objective lens use the coarse focus knob 3 to focus on the specimen 1 Always start with the lowest power 4x objective lens and switch to higher power by rotating the nosepiece 12 to the 10x and then 40x objective lenses Be cautious not to let the objective lens touch the specimen slide when changing to higher power 2 Use the fine focus knob 11 to change the depth of field and obtain precise focus on the specimen you are observing 3 Ifyourun out of downward travel before reaching sharp focus you can unscrew the safety screw 9 to allow for more downward travel Once again be careful not to let the objective lens touch the specimen slide Advanced Microscope Model 44104 10 Arm o 11 Fine Focus Knob 9 Safety Rack Stop 4 8 Stage Holder Clamp gt 1 1 Eyepiece 2 Eyepiece Tube 3 Coarse Focus Knob 12 Nosepiece i 4 Objectiv
74. lende 13 SNA un Aufbau des Mikroskops Nehmen Sie den Styroporbeh lter aus dem Karton Entfernen Sie das Klebeband vom Styroporbeh lter mit dem die beiden Teile zusammengehalten werden Nehmen Sie das Mikroskop und die anderen Teile vorsichtig aus dem Beh lter und stellen Sie sie auf einen Tisch Schreibtisch oder eine andere flache Oberfl che Entfernen Sie den Plastikbeutel mit dem das Mikroskop gesch tzt ist Entfernen Sie das Schutzpapier vom Objekttisch 5 Entfernen Sie die vier Objektivlinsen 4 aus ihren Beh ltern Schrauben Sie die Beh lterdeckel vom Gewindeteil der Objektivlinsen ab Schrauben Sie das Ende der 4 mm Objektivlinse in eine der ffnungen am Revolver 12 und ziehen Sie sie von Hand fest Der Objektivtisch 5 muss u U abgesenkt werden indem der Grobtriebknopf 3 gedreht wird Drehen Sie jetzt den Revolver zur n chsten ffnung und schrauben Sie die restlichen Objektivlinsen in die restlichen Offnungen Ihr Mikroskop ist jetzt einsatzbereit Betrieb des Mikroskops Verwendung des Beleuchtungsspiegels Das Mikroskop umfasst einen integrierten plankonkaven Beleuchtungsspiegel der die Beleuchtung der Probe von unten ermoglicht indem er eine externe Lichtquelle indirektes Sonnenlicht Zimmerbeleuchtung Lampe etc auf den Objekttisch reflektiert Der Spiegel weist eine flache Seite Ihr Spiegelbild ist auf der flachen Oberfl che leicht zu sehen und eine konkave Seite auf Die konkave Seite k
75. les Remettez le support de fixation du compartiment piles en position l aide des deux vis cruciformes brillantes Replacez la grille avec les quatre vis cruciformes pieds en caoutchouc 15 Observation d un chantillon Votre instrument est livr avec une platine m canique dot e d une pince valet et de boutons directionnels voir figures 4g et 4h L utilisation sur les deux axes d une chelle vernier permet de marquer et de copier avec pr cision un objet dans le champ de vision sur lequel l observateur peut souhaiter revenir 1 Utilisez le levier de la pince valet pour ouvrir le bras de serrage de la pince valet de la platine 2 Placez une lame porte objets dimensions 3 po 7 5 cm l int rieur de la pince valet et refermez d licatement le bras de serrage contre la lame porte objets 3 Utilisez les boutons de d placement de la platine voir Figure 4h pour positionner l chantillon sur l ouverture de la platine 5 Vous pouvez maintenant faire une mise au point et observer l chantillon mais vous devez n anmoins prendre certaines pr cautions pour ne pas endommager la lame porte objets ou l objectif Votre microscope est quip d une but e de s curit 9 qui vous permet de r gler le trajet de la cr maill re sur le dispositif de mise au point Cette but e est destin e viter tout contact accidentel de l objectif et de la lame porte objets afin de ne pas briser la lame ou de rayer l objectif Pour r gle
76. llung reagiert 2 Wenn Sie den Spiegel nicht so einstellen k nnen dass die Probe ausreichend beleuchtet wird k nnen Sie auch den Arm 10 nach hinten neigen um die Position des Spiegels zu ndern 3 Die Lichtmenge kann auch durch Drehen des Scheibendiaphragmas mit f nf Blendengr en siehe Abb 2a unter dem Objekttisch 5 reguliert werden Einstellung des Armwinkels Die normale Betrachtungsposition ist bei 0 Es sind aber auch andere Betrachtungswinkel von 0 bis 60 m glich Anderung des Betrachtungswinkels 1 Halten Sie den Mikroskopfu 7 mit einer Hand fest 2 Neigen Sie dann mit der anderen Hand den Arm 10 indem Sie ihn nach hinten oder vorn in den gew nschten Betrachtungswinkel ziehen Kondensor Scheibendiaphragma Abb 2a Betrachtung einer Probe Setzen Sie vorsichtig einen Proben Objekttr ger unter die Federklemmen 8 des Objekttisches und zentrieren Sie die Probe genau ber der Offnung in der Mitte des Objekttisches 5 Jetzt k nnen Sie das Mikroskop scharf einstellen und die Probe betrachten aber zuerst m ssen Sie noch einige Vorsichtsma nahmen ergreifen damit der Objekttr ger oder die Objektivlinse nicht besch digt werden Ihr Mikroskop ist mit einem Anschlagschutz 9 versehen der die Regulierung des Bewegungsbereichs am Fokussierer erm glicht Damit wird sichergestellt dass die Objektivlinse nicht versehentlich mit dem Objekttr ger in Kontakt kommt denn dabei k nnte der Objekttr ger
77. luminateur lectrique livr avec Pour installer l illuminateur lectrique 1 Retirez l illuminateur du miroir en le sortant de son tui Il suffit d une l g re pression pour le sortir facilement voir Figure 3a 2 Installez l illuminateur lectrique dans l tui d o vous venez de retirer l illuminateur du miroir voir Figure 3a 3 Veillez ce que la partie en verre de l illuminateur lectrique voir Figure 3b soit dirig e vers le haut de la platine 5 4 Placez la broche de l illuminateur et les fixations sur l tui et enfoncez le fond voir Figure 3c 5 Branchez le cordon de l illuminateur lectrique dans une prise d alimentation c a adapt e voir Figure 3d Changement des oculaires Votre microscope est livr avec deux oculaires de 10x et 12 5x Ils sont facilement interchangeables Retirez l un ou l autre des oculaires 1 du tube oculaire 2 en tirant vers le haut 2 Installez l oculaire que vous souhaitez utiliser 1 dans le tube oculaire 2 en l enfon ant vers le bas 3 Les oculaires sont maintenus en place par un ajustement serr Observation d un chantillon Votre instrument est livr avec une platine m canique dot e d une pince valet et de boutons directionnels voir figure 3e I Utilisez le levier de la pince valet pour ouvrir le bras de serrage de la pince valet de la platine 2 Placez une lame porte objets dimensions 3 po 7 5 cm l int rieur de la pince valet et r
78. lver 12 bis sich die 40x Linse ber der Probe befindet 7 Lassen Sie die Objektivlinse auf den Objekttr ger herab bis die Spitze der Linse sich kurz ber dem Objekttr ger befindet Aufpassen dass die Objektivlinse nicht mit dem Objekttr ger in Kontakt kommt Drehen Sie die Anschlagschutzschraube 9 nach oben bis sie am Fokusmechanismus auftrifft 9 Drehen Sie die R ndelmutter nach oben um die Anschlagschutzschraube in dieser Stellung zu arretieren Ge Abbe Kondensor Irisblende Objekttischkn pfe Abb 4h Tipp Zur Positionierung der Probe direkt unter der Objektivlinse schlieBen Sie die Offnung an der Irisblende siehe Abb 4h bis sie fast vollst ndig geschlossen ist Jetzt m sste ein kleiner Lichtstrahl sichtbar sein der auf den Objekttr ger projiziert wird Nun k nnen Sie die Probe direkt in den Lichtstrahl mithilfe der Objekttischkn pfe bewegen 10 Drehen Sie die Objektivlinsen 4 mithilfe des Revolvers 12 bis das 4x Objektiv sich direkt ber der Probe befindet Immer mit dem Objektiv mit der kleinsten VergroBerung beginnen und zu den h heren Vergr ferungen hinaufarbeiten 11 Schauen Sie durch das Okular w hrend Sie den Grobtriebknopf 3 drehen bis die Probe ins Sichtfeld r ckt Sie m ssen eventuell die Objekttischkn pfe Abb 4h leicht einstellen um die Probe im Sichtfeld zu zentrieren Achtung Achten Sie darauf dass Sie bei der Fokussierung den Probenobjekttisch nicht so hoch anheben
79. mecanismo de enfoque 1 Haga girar la perilla macrom trica 3 hacia atr s en el sentido de las agujas del reloj para elevar el objetivo alej ndolo de la platina 5 2 Desenrosque unos 2 3 del tornillo del tope de seguridad de la platina 9 3 Gire el rev lver 12 hasta colocar el objetivo de 40x sobre el esp cimen 4 Baje el objetivo sobre el portaobjetos hasta que la punta del lente est casi encima del mismo Tenga mucho cuidado y no permita que el objetivo toque el portaobjetos 5 Enrosque el tornillo de seguridad 9 hacia arriba hasta que se tope contra el mecanismo de enfoque 6 Haga girar la tuerca de retenci n estriada hacia arriba para trabar el tornillo de seguridad Enfoque Ahora que tiene el portaobjetos directamente debajo del objetivo use la perilla macrom trica 3 para enfocar el esp cimen 1 Siempre empiece con el aumento m s bajo objetivo de 4x y cambie a un aumento m s alto girando el rev lver 12 al objetivo de 10x primero y de 40x despu s Tenga cuidado y no permita que el objetivo toque el portaobjetos cuando cambie a un aumento mayor 2 Use la perilla microm trica 11 para cambiar la profundidad de campo y obtener un enfoque preciso del esp cimen que est observando 3 Sila distancia hacia abajo para enfocar no es suficiente desatornille el tornillo de seguridad 9 para ampliar la distancia de recorrido hacia abajo Una vez m s tenga mucho cuidado y no permita que el objetivo toque el
80. men 120 mm x 110 mm Arm Winkelbereich 0 bis 60 Fokussierer Grob und Feintrieb Rack und Pinion Anschlagschutz Achromatisch 4x 40 Vergr Berungsleistung 10x 100 Objektive Vergr erungsleistung 40x 400 Vergr Berungsleistung Beleuchtung Plankonkaver Spiegel 50 mm Okular 10x 12 mm Sichtfeld Objektivwechselrevolver Kondensor Dreifach mit Klickstopp N A 0 65 Diaphragma Blende Scheibendiaphragma mit f nf Blendengr en Aufbau des Mikroskops Nehmen Sie den Styroporbeh lter aus dem Karton Entfernen Sie das Klebeband vom Styroporbeh lter mit dem die beiden Teile zusammengehalten werden Nehmen Sie das Mikroskop und die anderen Teile vorsichtig aus dem Beh lter und stellen Sie sie auf einen Tisch Schreibtisch oder eine andere flache Oberfl che Entfernen Sie den Plastikbeutel mit dem das Mikroskop gesch tzt ist Entfernen Sie das Schutzpapier vom Objekttisch 5 Entfernen Sie den Kunststoffdeckel vom Okulartubus 2 Stecken Sie das 10x Okular in den Okulartubus 2 Entfernen Sie die drei Objektivlinsen 4 aus ihren Beh ltern Schrauben Sie die Beh lterdeckel vom Gewindeteil der Objektivlinsen ab Schrauben Sie das Ende der 4 mm Objektivlinse in eine der ffnungen am Revolver 12 und ziehen Sie sie von Hand fest Der Objektivtisch 5 muss u U abgesenkt werden indem der Grobtriebknopf 3 gedreht wird 10 Drehen Sie jetzt den Revolver zur n chsten
81. mueve en el eje X hacia adelante y hacia atr s mientras que la perilla inferior de movimiento de la platina se mueve en el eje Y de lado a lado La escala Vernier en ambos ejes permite marcar y duplicar exactamente la ubicaci n de un objeto en caso de que el usuario desee volver al mismo campo de visi n Perillas de movimiento de la platina Figura 3e Sugerencia Para colocar el esp cimen directamente debajo del objetivo cierre la abertura del diafragma iris ver la Figura 3f hasta que est casi completamente cerrado Podr ver un peque o haz de luz que se proyecta sobre el portaobjetos Ahora simplemente use las perillas de movimiento de la platina para mover el esp cimen directamente dentro del haz de luz 10 Use el rev lver 12 para girar los objetivos 4 hasta que el objetivo de 4x quede directamente sobre el esp cimen Comience siempre son el objetivo de menor aumento y contin e subiendo el aumento 11 Mire a trav s del ocular al mismo tiempo que gira la perilla macrom trica 3 hasta que el esp cimen quede a la vista Si necesita centrar el esp cimen en el campo de visi n mueva levemente las perillas de la platina Figura 3e Advertencia Cuando enfoque cuide de no levantar la platina demasiado de manera que el portaobjetos toque el objetivo No solo podr a romper el portaobjetos sino que tambi n puede rayar el objetivo 12 Por ltimo ajuste la perilla microm trica 11 hasta alcanzar el enfoque m s
82. n Objektivlinse 4x 10x 40x 10x Okular 40x 100x 400x 12 5x Okular 50x 125x 500x Aufbau des Mikroskops 1 Nehmen Sie den Styroporbeh lter aus dem Karton 2 Entfernen Sie das Klebeband vom Styroporbeh lter mit dem die beiden Teile zusammengehalten werden 3 Nehmen Sie das Mikroskop und die anderen Teile vorsichtig aus dem Beh lter und stellen Sie sie auf einen Tisch Schreibtisch oder eine andere flache Oberfl che 4 Entfernen Sie den Plastikbeutel mit dem das Mikroskop gesch tzt ist 5 Entfernen Sie das Schutzpapier vom Objekttisch 5 6 Entfernen Sie den Kunststoffdeckel vom Okulartubus 2 7 Stecken Sie das 10x Okular in den Okulartubus 2 8 Entfernen Sie die drei Objektivlinsen 4 aus ihren Beh ltern Schrauben Sie die Beh lterdeckel vom Gewindeteil der Objektivlinsen ab 9 Schrauben Sie das Ende der 4 mm Objektivlinse in eine der ffnungen am Revolver 12 und ziehen Sie sie von Hand fest Der Objektivtisch 5 muss u U abgesenkt werden indem der Grobtriebknopf 3 gedreht wird 10 Drehen Sie jetzt den Revolver zur n chsten Offnung und schrauben Sie die restlichen Objektivlinsen in die restlichen ffnungen Ihr Mikroskop ist jetzt einsatzbereit Betrieb des Mikroskops Verwendung des Beleuchtungsspiegels Das Mikroskop umfasst einen integrierten plankonkaven Beleuchtungsspiegel der die Beleuchtung der Probe von unten erm glicht indem er eine externe Lichtquelle indirektes Sonnenl
83. n tido posible para su vista Advertencia Nunca haga girar las perillas microm tricas en direcci n opuesta al mismo tiempo ya que podr a da ar el mecanismo de enfoque Condensador Abbe Perilla para regular el condensador Palanca del diafragma iris Figura 3f 11 Ajuste de la luz Los espec menes de diferentes tama os espesores y variaciones de colores requieren diferentes niveles de iluminaci n Existen dos maneras de cambiar la cantidad de luz cuando se observa un esp cimen regular el condensador Abbe y regular el diafragma iris ver Figura 3f 1 Cuando se realiza la observaci n con objetivos de menor aumento de 4x y 10x debe bajar el lente del condensador para dispersar la luz sobre el campo de visi n m s amplio Para cambiar la posici n del condensador haga girar la perilla para regular el condensador en sentido de las agujas del reloj hasta que el haz de luz se disperse lo suficiente para iluminar el campo de visi n por completo 2 Laimagen aparecer menos iluminada cuando baje el condensador para dispersar la luz o cuando cambie a un objetivo de m s aumento Aumente la apertura del diafragma iris para permitir que pase m s luz La apertura o cierre del diafragma le ofrece una vista en relieve del esp cimen y le permite cambiar la profundidad de campo del esp cimen que est observando Uso de un filtro Para resaltar los diferentes niveles de detalle experimente cambiando el color de la iluminaci n t
84. nto de la platina ver la Figura 4h para colocar el esp cimen sobre la abertura de la platina 5 Ahora est listo para enfocar y observar el esp cimen pero primero debe tomar ciertas precauciones para no da ar el portaobjetos o el objetivo El microscopio est equipado con un tope de seguridad de la platina 9 que permite regular la distancia de recorrido del mecanismo de enfoque Esto asegura que el objetivo no haga contacto accidentalmente con el portaobjetos ya que podr a romperlo o podr a rayarse el objetivo Para regular la distancia de recorrido del mecanismo de enfoque 4 Haga girar la perilla macrom trica 3 hacia atr s en el sentido de las agujas del reloj para elevar el objetivo alej ndolo de la platina 5 5 Desenrosque unos 2 3 del tornillo del tope de seguridad de la platina 9 6 Gire el rev lver 12 hasta colocar el objetivo de 40x sobre el esp cimen 7 Baje el objetivo sobre el portaobjetos hasta que la punta del lente est casi encima del mismo Tenga mucho cuidado y no permita que el objetivo toque el portaobjetos Enrosque el tornillo de seguridad 9 hacia arriba hasta que se tope contra el mecanismo de enfoque 9 Haga girar la tuerca de retenci n estriada hacia arriba para trabar el tornillo de seguridad oo Condensador Abbe Diafragma iris Perillas de movimiento de la platina T Figura 4g Figura 4h Sugerencia Para colocar el esp cimen directamente debajo del objetivo ci
85. ntretien faciles suivre pour augmenter la qualit de la performance de votre microscope pendant des ann es et la satisfaction de son utilisation Microscope de laboratoire Mod le n 44100 1 Oculaire 2 Tube de l oculaire 10 Potence 3 Bouton de mise au point 9 But e de s curit de la cr maill re 4 Objectif 5 Platine chantillons 8 Leviers ressorts de la platine i 6 Miroir illuminateur V 7 Socle CELESTRON Figure 1 Accessoires standard libr s aber botre microscope e Oculaire de Huygens 10x e 5 lames porte objets pr par es e Objectif 20x 200x avec l oculaire e House de protection Specifications Modele n 44100 Specifications Platine Platine simple avec leviers ressorts 88 mm x 88 mm Potence Choix d angles de 09 a 459 Dispositif de mise au point Grossi re cr maill re et pignon avec but e de s curit Objectif Achromatique 20x llluminateur Miroir plan et concave de 42 mm Oculaire 10X Champ de vision 12 mm Installation de votre microscope 1 Sortez la bo te en polystyr ne expans de son carton 2 Retirez le ruban adh sif de la bo te en polystyr ne expans en maintenant les deux parties ensemble 3 Retirez d licatement le microscope et les autres pi ces et installez les sur une table un bureau ou toute autre surface plane 4 Retirez l emballage plastique prot geant le micr
86. oben ziehen 2 Setzen Sie das gew nschte Okular 1 im Okulartubus 2 ein indem Sie es nach unten dr cken 3 Die Okulare sitzen durch Reibungspassung fest Betrachtung einer Probe Ihr Instrument ist mit einem mechanischen Objekttisch mit einer Objekttisch Halteklemme und Richtungsdrehkn pfen ausgestattet Siehe Abb 3e 1 ffnen Sie den Klemmarm der Objekttisch Halteklemme mit dem Klemmenhebel 2 Setzen Sie einen Objekttr ger 3 Zoll 7 62 cm Gr e im Halter ein und schlie en Sie den Klemmarm vorsichtig am Objekttr ger 3 Mit den Objekttischkn pfen siehe Abb 3e k nnen Sie die Probe ber der ffnung im Objekttisch 5 positionieren Jetzt k nnen Sie das Mikroskop scharf einstellen und die Probe betrachten aber zuerst m ssen Sie noch einige VorsichtsmaBnahmen ergreifen damit der Objekttr ger oder die Objektivlinse nicht besch digt werden Ihr Mikroskop ist mit einem Anschlagschutz 9 versehen der die Regulierung des Bewegungsbereichs am Fokussierer erm glicht Damit wird sichergestellt dass die Objektivlinse nicht versehentlich mit dem Objekttr ger in Kontakt kommt denn dabei konnte der Objekttr ger zerbrochen oder die Objektivlinse zerkratzt werden Einstellung des Bewegungsbereichs am Fokusmechanismus 4 Heben Sie die Objektivlinse vom Objekttisch 5 ab indem Sie den Grobtriebknopf 3 nach hinten drehen im Uhrzeigersinn 5 Drehen Sie die Anschlagschutzschraube 9 ca 2 3 heraus 6 Drehen Sie den Re
87. ommt denn dabei konnte der Objekttr ger zerbrochen oder die Objektivlinse zerkratzt werden Einstellung des Bewegungsbereichs am Fokusmechanismus 1 Heben Sie die Objektivlinse vom Objekttisch 5 ab indem Sie das Fokusrad 3 nach hinten drehen im Uhrzeigersinn 2 Drehen Sie die Anschlagschutzschraube 9 ca 2 3 heraus 3 Lassen Sie die Objektivlinse auf den Objekttr ger herab bis die Spitze der Linse sich kurz ber dem Objekttr ger befindet Aufpassen dass die Objektivlinse nicht mit dem Objekttr ger in Kontakt kommt 4 Drehen Sie die Anschlagschutzschraube 9 nach oben bis sie am Fokusmechanismus auftrifft Drehen Sie die R ndelmutter nach oben um die Anschlagschutzschraube in dieser Stellung zu arretieren 6 Drehen Sie jetzt das Fokusrad 3 bis die Probe scharf eingestellt ist 4 A Labormikroskop Modell 44102 10 Ari A 11 Feintriebknopf 9 Anschlagschutz 8 Gefederte Objekttischklemmen 1 Okular 2 Okulartubus 3 Grobtriebknopf 12 Objektivwechselrevolver 4 Objektivlinse bo 5 Objekttisch p I 1 7 a 6 Beleuchtungsspiegel Q CELESTRON 7 FuB Abb 2 Im Lieferumfang des Mikroskops enthaltenes Standardsubehor e 10x Huygens Okular e 40x Objektivlinse e 4x Objektivlinse e 5 fertige Objekttr ger e 10x Objektivlinse e Staubschutz Technische Daten Modell 44102 Technische Daten Objekttisch Einfacher Objekttisch mit Federklem
88. onzentriert mehr Licht auf die Probe als die flache Seite Beleuchtung einer Probe 1 Bei Tageslicht Neigen Sie den Spiegel 6 so dass indirektes Sonnenlicht durch die Unterseite des Objekttisches reflektiert wird 5 Achtung Niemals mithilfe des Spiegels direktes Sonnenlicht durch das Mikroskop richten Das kann sehr gef hrlich sein und Ihre Augen k nnen Schaden davontragen Bei Betrachtung nachts oder in Innenr umen ohne Sonneneinstrahlung k nnen Sie eine Schreibtisch oder Tischlampe oder andere Lichtquelle verwenden um Licht auf eine Probe zu reflektieren Regulierung der auf die Probe reflektierten Lichtmenge 1 Mit der konkaven Seite des Spiegels k nnen Sie mehr Licht auf den Objekttr ger fokussieren Die konkave Seite konzentriert mehr Licht auf Ihre Probe aber sie fokussiert einen kleineren Lichtstrahl der empfindlicher auf Einstellung reagiert Sie k nnen auch die Lichteinstellung mit dem Kondensor und dem Diaphragma Blende regulieren Siehe Abschnitt Einstellung der Beleuchtung Drehung des Kopfes Der Kopf des Mikroskops ist um 360 drehbar D h die Beobachtung kann aus jeder beliebigen Position erfolgen indem einfach nur der Kopf in die gew nschte Stellung gedreht wird 14 Verwendung der LED Beleuchtung Abb Aa Abb 4b Abb 4c F r eine direktere und intensivere Beleuchtung sollten Sie die im Lieferumfang enthaltene LED Beleuchtung verwenden Die LED Leuchte wird mit drei AA Batterien n
89. oscope 5 Retirez le papier de protection de la platine 5 6 Retirer le cache en plastique du tube de l oculaire 2 7 Ins rez l oculaire 10x dans le tube de l oculaire 2 Votre microscope est maintenant pr t l emploi Fonctionnement du microscope Utilisation du miroir illuminateur Votre microscope est quip d un miroir illuminateur int gr plan et concave qui vous permet d clairer l chantillon par dessous en r fl chissant une source externe de lumi re lumi re indirecte du soleil lumi re de la pi ce d une lampe etc sur la platine Le miroir poss de une surface plane sur laquelle il est vous est facile de voir votre reflet et une surface concave La face concave permet de faire converger davantage de lumi re sur l chantillon que la face plane Pour clairer un chantillon 1 Si vous b n ficiez de la lumi re du jour inclinez le miroir 6 et r fl chissez la lumi re indirecte du soleil par dessous la platine 5 Avertissement Ne jamais utiliser le miroir pour faire converger la lumi re directe du soleil travers le microscope pour ne pas risquer de graves l sions oculaires 2 Pour l observation de nuit ou l int rieur en ne b n ficiant pas de la lumi re du soleil vous pouvez utiliser une lampe de bureau de table ou toute autre source d clairage pour en r fl chir la lumi re sur un chantillon Pour contr ler la quantit de lumi re r fl chie sur l chantillon 1
90. otre reflet et une surface concave La face concave permet de faire converger davantage de lumi re sur l chantillon que la face plane Pour clairer un chantillon 1 Si vous b n ficiez de la lumi re du jour inclinez le miroir 6 et r fl chissez la lumi re indirecte du soleil par dessous la platine 5 Avertissement Ne jamais utiliser le miroir pour faire converger la lumi re directe du soleil travers le microscope pour ne pas risquer de graves l sions oculaires 2 Pour l observation de nuit ou l int rieur en ne b n ficiant pas de la lumi re du soleil vous pouvez utiliser une lampe de bureau de table ou toute autre source d clairage pour en r fl chir la lumi re sur un chantillon Pour contr ler la quantit de lumi re r fl chie sur l chantillon 1 Utilisez la face concave du miroir pour faire converger davantage de lumi re sur la lame porte objets La face concave permet de concentrer plus de lumi re sur votre chantillon mais le faisceau lumineux qu elle fait converger est plus troit ce qui rend son r glage plus d licat 2 Vous pouvez galement contr ler le r glage de la lumi re au moyen du condenseur et du diaphragme voir la rubrique sous R glage de l clairage Rotation de la t te La t te de votre microscope peut tourner sur 360 Il vous est donc possible d observer partir de n importe quelle position en d placant simplement la t te sur le point choisi 14 Util
91. oute autre source d clairage pour en r fl chir la lumi re sur un chantillon Pour contr ler la quantit de lumi re r fl chie sur l chantillon 1 Utilisez la face concave du miroir pour faire converger davantage de lumi re sur la lame porte objets La face concave permet de concentrer plus de lumi re sur votre chantillon mais le faisceau lumineux qu elle fait converger est plus troit ce qui rend son r glage plus d licat 2 S il ne vous est pas possible de r gler le miroir de mani re clairer correctement l chantillon vous pouvez incliner la potence 10 vers l arri re pour changer la position du miroir voir la rubrique sous R glage de l angle de la potence 3 Vous pouvez galement contr ler le r glage de la lumi re au moyen du condenseur et du diaphragme voir la rubrique sous R glage de l clairage R glage de l angle de la potence La position d observation habituelle est de 0 Toutefois vous pouvez observer des chantillons en utilisant n importe quel angle compris entre 0 et 60 Pour changer l angle optique 1 Tenez le socle d une main 7 2 Ensuite avec votre autre main inclinez la potence 10 en la ramenant vers l arri re ou vers l avant sur l angle optique recherch Utilisation de l illuminateur lectrique d 2 E Figure 3a Figure 3b Figure 3c Figure 3d Pour b n ficier d un clairage plus direct et intense nous vous conseillons d utiliser l il
92. oute d fectuosit au niveau des mat riaux et de la fabrication pendant une dur e de deux ans Celestron r parera ou remplacera tout produit ou pi ce qui apr s inspection par Celestron s av rera pr senter un vice de forme ou de fabrication Pour obtenir la r paration ou l change d un produit aupr s de Celestron il est n cessaire de renvoyer ce produit Celestron accompagn d une preuve d achat que Celestron jugera satisfaisante B Vous devez vous procurez au pr alable un num ro d autorisation de renvoi de marchandises aupr s de Celestron T l phonez Celestron au 310 328 9560 pour obtenir ce num ro qui devra ensuite figurer sur le carton de r exp dition Tous les articles retourn s doivent tre accompagn s d une d claration crite portant le nom l adresse et un num ro de t l phone o il est possible de joindre leur propri taire pendant la journ e ainsi qu une br ve description des probl mes invoqu s Les pi ces ou produits remplac s deviennent la propri t de Celestron Il incombe au client d assumer tous les frais d exp dition franco de port la fois pour l envoi initial et la r exp dition depuis l usine Celestron ainsi que les frais d assurance Celestron s engage faire de son mieux pour r parer ou remplacer tout microscope couvert par cette garantie dans les trente jours qui suivent sa r ception Si une r paration ou un change devait n cessiter plus de trente jours Celestron en aviser
93. portaobjetos 10 Brazo 11 Perilla microm trica 9 Tope de seguridad de la platina 8 Pinza sujetadora de la platina Microscopio abanzado Modelo 42 44104 1 Ocular 2 Tubo del ocular 3 Perilla macrom trica 12 Rev lver 4 Objetivo 5 Platina 6 Espejo luminoso amp CELESTRON 7 Base Figura 3 Accesorios est ndar incluidos con el microscopio e Ocular Huygens de 10x e Iluminador el ctrico e Ocular Huygens de 12 5x e Filtro azul e Objetivo de 4x e 5preparaciones en portaobjetos e Objetivo de 10x e Cubierta contra el polvo e Objetivo de 40x Especificaciones Modelo N 44104 Especificaciones Platina Platina mec nica de 115 mm x 125 mm Brazo Selecci n de ngulo de 0 a 60 Mecanismo de enfoque Objetivos Perillas macrom trica y microm trica tope de seguridad de pi n y cremallera Acrom tico 4x 10x 40x Iluminador Espejo plano c ncavo de 50 mm Oculares Campo de visi n de 10 mm 12 mm Campo de visi n de 12 5 mm 10 mm Rev lver Triple con clic de parada Condensador Abbe N A 1 25 Diafragma Iris Tabla be aumentos Utilice la tabla a continuaci n para determinar los aumentos de la combinaci n de los diferentes oculares y objetivos del microscopio Objetivo 4x 10x 40x Ocular de 10x 40x 100x 400x Ocular de 12 5x 50x 125x 500x Desembala
94. r et des variations de couleur Il existe trois mani res de modifier l intensit de l clairage pendant l observation d un chantillon en r glant la commande de luminosit sur le bouton on off marche arr t 13 en r glant le condenseur d Abbe Figure 4g et en r glant le diaphragme iris voir Figure 4h 1 Pour l observation d un chantillon qui manque de transparence ou qui est sombre il peut tre n cessaire d augmenter l intensit lumineuse pour faire ressortir certaines caract ristiques ou certains d tails Le moyen le plus facile d y parvenir est d augmenter simplement l intensit de l illuminateur LED en tournant fond la commande d intensit sur l interrupteur on off marche arr t 13 sur son r glage le plus lev Lorsque vous observez avec des objectifs de faible puissance 4x et 10x il vous faut abaisser la lentille du condenseur afin de r partir l clairage sur un champ de vision plus important Pour changer la position du condenseur il suffit de tourner la partie argent e centrale du diaphgrame iris 4h dans le sens horaire jusqu ce que le faisceau lumineux soit suffisamment important pour clairer la totalit du champ de vision lors de l observation Lorsque vous abaissez le condenseur pour r partir l clairage ou que vous passez des objectifs plus puissants l image appara t plus floue Au lieu d augmenter l intensit d clairage de l illuminateur qui peut d laver
95. r le trajet sur le m canisme de mise au point 4 Relevez l objectif en tournant le bouton de mise au point 3 vers l arri re sens horaire pour l loigner de la platine 5 D vissez la vis d arr t 9 de la but e de s curit de la cr maill re sur environ 2 3 de la longueur Tournez la tourelle 12 jusqu ce que l objectif 40x soit au dessus de l chantillon 7 Abaissez l objectif sur la lame porte objets jusqu ce que l extr mit de l objectif se trouve l g rement au dessus de la lame Veillez ne pas toucher la lame porte objets avec l objectif 8 Vissez la vis de s curit 9 vers le haut jusqu ce qu elle butte contre le m canisme de mise au point 9 Tournez le contre crou molet vers le haut pour bloquer la vis de s curit en position Di Condenseur d Abbe Diaphragme iris Boutons de d placement de la platine Figure 4g Figure 4h Conseil utile Pour positionner l chantillon directement sous l objectif r duisez l ouverture du diaphragme iris voir Figure 4h jusqu ce qu il soit pratiquement ferm Vous devriez apercevoir un petit faisceau lumineux projet sur la lame porte objets Maintenant il suffit d utiliser les boutons de d placement de la platine pour d placer l chantillon l int rieur du faisceau lumineux 10 Utilisez la tourelle 12 pour tournez les objectifs 4 jusqu ce que l objectif 4x soit directement au dessus de l chantillon Commencez toujours a
96. rasera del esp cimen Para cambiar el color de iluminaci n coloque el filtro azul en el haz de luz en la parte superior del iluminador el ctrico Quiz tenga que reenfocar ajustando la perilla microm trica 11 levemente para poder observar mejor Reemplazo de la l mpara del iluminador el ctrico pu E Tornillo de apriete manual Figura 3g 12 Para reemplazar una l mpara quemada haga lo siguiente 1 Quite el tornillo de apriete manual del iluminador haci ndolo girar en el sentido contrario a las agujas del reloj Abra el compartimiento donde encontrar la l mpara de tungsteno de 20 vatios Quite la l mpara empuj ndola levemente hacia abajo y haci ndola girar en sentido contrario a las agujas del reloj Alinee los clavijas de la l mpara nueva con las ranuras en el portal mpara y emp jela hacia abajo girando en el sentido de las agujas del reloj hasta que quede colocada Cierre el compartimiento alinee el agujero roscado para el tornillo de apriete manual y apri telo haci ndolo girar en el sentido de las agujas del reloj Microscopio avanzado Modelo 32 44106 1 Ocular 2 Tubo del ocular rd 14 Cabezal 12 Rev lver NE 4 Objetivo 5 Platina 10 Brazo 4 9 Tope de seguridad de la platina 8 Pinza sujetadora de la platina 6 Iluminador LED 3 Perilla macrom trica diodo luminiscente 13 Interruptor de encendido apagado On Off 11
97. rtion of the objective lenses 9 Thread the end of the 4mm objective lens into one of the holes on the nosepiece 12 until finger tight It may be necessary to lower the stage 5 by turning the coarse focus knob 3 10 Now turn the nosepiece to the next opening and thread each of the remaining objective lenses into the remaining holes You are now ready to use your microscope Microscope Operation Using the Illuminator Mirror Your microscope has a built in plano concave illumination mirror which allows you to illuminate the specimen from the bottom by reflecting an external light source indirect sunlight room light lamp etc to the stage The mirror has a flat side you can easily see your reflection on the flat surface and a concave side The concave side will concentrate more light onto the specimen than the flat side To illuminate a specimen 1 If it is daylight tilt the mirror 6 and reflect indirect sunlight through the bottom of the stage 5 Warning Never use the mirror to focus direct sunlight through the microscope as this can be very harmful and may damage your eyes If viewing at night or indoors away from sunlight you can use a nearby desk lamp table lamp or other light source to reflect light onto a specimen To control the amount of light reflecting onto the specimen 1 2 3 Use the concave side of the mirror to focus more light on the slide The concave side will concentrate more light onto
98. rtissement Lors de la mise au point veillez ne pas relever la platine chantillons afin d viter tout contact entre la lame porte objets et l objectif Non seulement vous risqueriez de briser votre lame porte objet mais vous pourriez rayer l objectif 12 Pour finir r glez le bouton de mise au point fine 11 jusqu obtenir l image la plus nette pour votre ceil Avertissement Ne jamais tourner simultan ment les deux boutons de mise au point fine dans des directions oppos es sous peine d endommager le m canisme de mise au point Condenseur d Abbe Bouton de r glage du condenseur Levier du diaphragme iris Figure 3f 11 R glage de l clairage Les chantillons devront tre clair s diff remment en fonction de leur taille de leur paisseur et des variations de couleur Il existe deux mani res de modifier l intensit de l clairage pendant l observation d un chantillon en ajustant le condenseur d Abbe et en ajustant le diaphragme iris voir Figure 3f 1 Lors d une observation avec des objectifs de faible puissance 4x et 10x il vous faut abaisser la lentille du condenseur afin de r partir l clairage sur un champ de vision plus important Pour changer la position du condenseur il suffit de tourner le bouton de r glage du condenseur dans le sens horaire jusqu ce que le faisceau lumineux soit suffisamment important pour clairer la totalit du champ de vision lors de l observation 2 Lorsqu
99. s zu sehen 17 Pflege und Wartung Ihr Celestron Mikroskop ist ein optisches Pr zisionsinstrument das stets mit der erforderlichen Sorgfalt behandelt werden sollte Wenn Sie diese Empfehlungen zur Pflege und Wartung befolgen erfordert Ihr Mikroskop w hrend seiner Lebensdauer nur sehr wenig Wartung Wenn Sie die Arbeit mit dem Mikroskop beendet haben entfernen Sie alle Probenreste auf dem Objekttisch Schalten Sie alle Kn pfe oder Schalter f r die elektrische Beleuchtung aus Ziehen Sie alle Netzkabel ab die benutzt wurden Bei Nichtgebrauch oder Lagerung stets den Staubschutz des Mikroskops anlegen Das Mikroskop an einem trockenen sauberen Ort aufbewahren Bei Gebrauch des Mikroskops in direktem Sonnenlicht sehr vorsichtig vorgehen um Besch digung des Mikroskops oder Augenverletzungen zu verh ten Das Mikroskop nur mit einer Hand am Arm nicht den Fokussierknopfen dem Okulargeh use etc transportieren Mit der anderen Hand zur Unterst tzung unter den Fuf fassen Reinigen Sie die uBeren Oberfl chen Metall und Kunststoff mit einem feuchten Lappen Vor Reinigungsarbeiten erst alle Kabel abziehen Niemals optische Oberfl chen mit Stoff oder Papiert chern reinigen da sie optische Oberfl chen leicht zerkratzen k nnen Staub mit einem Kamelhaarpinsel oder einem Luftgebl se von den optischen Oberfl chen abpusten Zur Entfernung von Fingerabdr cken von optischen Oberfl chen verwenden Sie ein Objektivreinigungsm
100. sichtig heraus und stellen Sie sie auf einen Tisch Schreibtisch oder eine andere flache Oberfl che 4 Entfernen Sie den Plastikbeutel mit dem das Mikroskop gesch tzt ist 5 Entfernen Sie das Schutzpapier vom Objekttisch 5 6 Entfernen Sie den Kunststoffdeckel vom Okulartubus 2 7 Stecken Sie das 10x Okular in den Okulartubus 2 Ihr Mikroskop ist jetzt einsatzbereit Betrieb des Mikroskops Verwendung des Beleuchtungsspiegels Das Mikroskop umfasst einen integrierten plankonkaven Beleuchtungsspiegel der die Beleuchtung der Probe von unten erm glicht indem er eine externe Lichtquelle indirektes Sonnenlicht Zimmerbeleuchtung Lampe etc auf den Objekttisch reflektiert Der Spiegel weist eine flache Seite Ihr Spiegelbild ist auf der flachen Oberfl che leicht zu sehen und eine konkave Seite auf Die konkave Seite konzentriert mehr Licht auf die Probe als die flache Seite Beleuchtung einer Probe 1 Bei Tageslicht Neigen Sie den Spiegel 6 so dass indirektes Sonnenlicht durch die Unterseite des Objekttisches reflektiert wird 5 Achtung Niemals mithilfe des Spiegels direktes Sonnenlicht durch das Mikroskop richten Das kann sehr gef hrlich sein und Ihre Augen k nnen Schaden davontragen 2 Bei Betrachtung nachts oder in Innenr umen ohne Sonneneinstrahlung k nnen Sie eine Schreibtisch oder Tischlampe oder andere Lichtquelle verwenden um Licht auf eine Probe zu reflektieren Regulierung der auf die Probe reflektierten Li
101. ste manual de instrucciones cubre cuatro modelos de microscopios Encuentre su modelo espec fico para cerciorarse de que lee la informaci n correcta Antes de usar el microscopio lea detenidamente las instrucciones para familiarizarse con las funciones y funcionamiento para que pueda disfrutarlo y utilizarlo a su m xima potencia Vea los diagramas del microscopio para ubicar las partes que se describen en este manual Los microscopios que se describen en este manual proporcionan aumentos de 40 hasta 1000x Estos tipos de microscopios son ideales para el estudio de portaobjetos de levaduras y mohos cultivos partes de plantas o animales fibras bacterias etc La secci n final contiene consejos para el f cil cuidado y mantenimiento del microscopio que deber seguir para aprovechar a os de rendimiento uso y aplicaci n de calidad Microscopio de laboratorio Modelo 32 44100 5 1 Ocular 2 Tubo del ocular 10 Brazo 3 Perilla de enfoque 9 Tope de seguridad 4 Objetivo de la platina 5 Platina 8 Presillas a resorte de la platina 6 Espejo luminoso QAELES7 RON 7 Base Figura 1 Accesorios est ndar inclu dos con el microscopio e Ocular Huygens de 10x e 5preparaciones en portaobjetos e Objetivo de 20x 200x con ocular e Cubierta contra el polvo Esperificaciones Modelo N 44100 Especificaciones Platina Platina lisa con presillas a
102. tch the objective lens 12 Finally adjust the fine focus knob 11 until you reach the sharpest focus for your eye Warning Never rotate both of the fine focus knobs at the same time in opposite directions or the focusing mechanism may get damaged Tip When viewing a specimen with the 100x objective lens you can improve the resolving power by placing a small drop of immersion oil between the specimen and objective lens For specimen slides that you prepare yourself always cover the specimen with a thin piece of glass and place the oil on the cover glass Do not put the oil directly on the specimen sample 16 Adjusting the Lighting Specimens of different size thickness and color variations will require different levels of illumination There are three ways to change the amount of illumination when viewing a specimen adjusting the brightness control on the on off knob 13 adjusting the Abbe condenser Figure 4g and adjusting the iris diaphragm see Figure 4h 1 When viewing a specimen that is not transparent or dark in color you may need to increase the amount of light to resolve certain features or details This is best done by simply increasing the brightness of the LED illuminator by rotating the brightness control on the on off switch 13 all the way to its highest setting 2 When viewing with lower power 4x and 10x objective lenses you will need to lower the condenser lens in order to spread the light over the larger field of v
103. tivo El microscopio est equipado con un tope de seguridad de la platina 9 que permite regular la distancia de recorrido del mecanismo de enfoque Esto asegura que el objetivo no haga contacto accidentalmente con el portaobjetos ya que podr a romperlo o podr a rayarse el objetivo Para regular la distancia de recorrido del mecanismo de enfoque 1 Haga girar la perilla de enfoque 3 hacia atr s en el sentido de las agujas del reloj para elevar el objetivo alej ndolo de la platina 5 2 Desenrosque unos 2 3 del tornillo del tope de seguridad de la platina 9 3 Baje el objetivo sobre el portaobjetos hasta que la punta del lente est casi encima del mismo Tenga mucho cuidado y no permita que el objetivo toque el portaobjetos 4 Enrosque el tornillo de seguridad 9 hacia arriba hasta que se tope contra el mecanismo de enfoque Haga girar la tuerca de retenci n estriada hacia arriba para trabar el tornillo de seguridad 6 Ahora gire la perilla de enfoque 3 hasta que el esp cimen est bien enfocado kul Microscopio de laboratorio Modelo 42 44102 1 Ocular 2 Tubo del ocular 3 Perilla macrom trica 10 Brazo E 3 11 Perilla microm trica 121498 9 Tope de seguridad de la platina 12 Rev lver 4 Objetivo 5 Platina 8 Presillas a resorte de la platina 6 Espejo luminoso on CELESTRON 7 Base Figura 2 Accesorios est ndar incluidos con el microscopio
104. to ensure that your microscope provides you with years of quality performance usage and enjoyment Laboratory Microscope Model ff 44100 gt 4 Eyepiece 2 Eyepiece Tube 10 Arm 3 Focus Knob 9 Safety Rack 4 Objective Lens Stop 5 Specimen Stage 8 Spring Loaded Stage Clips 6 Illumination Mirror BEEN 7 10 Figure 1 Standard Accessories Included with pour Microscope e 10x Huygens Eyepiece e 5 Prepared Slides e 20x Objective Lens 200x with eyepiece e Dust Cover Specifications Model 44100 Specifications Stage Plain Stage with spring loaded clips 88mm x 88mm Arm Angle choice from 0 to 45 Focuser Coarse Rack and Pinion with Safety Stop Objective Achromatic 20x Illuminator 42mm Plano Concave Mirror Eyepiece 10X 12mm Field of View Setting Up Pour Microscope Take the Styrofoam container out of the cardboard carton Remove the tape from the Styrofoam container holding the two sections together Carefully remove the microscope and other parts and set them on a table desk or other flat surface Remove the plastic bag covering the microscope Remove the protective paper from the stage 5 Remove the plastic cap from the eyepiece tube 2 Insert the 10x eyepiece in the eyepiece tube 2 Your microscope is now ready to use Show Un BG Microscope Operation Using the Illuminator Mirror Your microscope has a built in plano con
105. turning the coarse focus knob 3 until the specimen comes into view You may need to adjust the stage knobs Figure 3e slightly to center the specimen in the field of view Warning When focusing be careful not to raise the specimen stage so high that the specimen slide touches the objective lens Not only can you break your slide but you may scratch the objective lens 12 Finally adjust the fine focus knob 11 until you reach the sharpest focus for your eye Warning Never rotate both of the fine focus knobs at the same time in opposite directions or the focusing mechanism may get damaged Abbe Condenser Condenser Regulator Knob Iris Diaphragm Lever Figure 3f 11 Adjusting the Lighting Specimens of different size thickness and color variations will require different levels of illumination There are two ways to change the amount of illumination when viewing a specimen adjusting the Abbe condenser and adjusting the iris diaphragm see Figure 3f 1 When viewing with lower power 4x and 10x objective lenses you will need to lower the condenser lens in order to spread the light over the larger field of view To change the position of the condenser simply rotate the condenser regulator knob clockwise until the beam of light spreads wide enough to illuminate the entire field of view when viewing 2 As you lower the condenser to spread out the light or change to a higher power objective lens your image will appear dimmer Op
106. ur Abbe N A 1 25 Diaphragme Iris 13 Installation de votre microscope Sortez la boite en polystyr ne expans de son carton Retirez le ruban adh sif de la bo te en polystyr ne expans en maintenant les deux parties ensemble Retirez d licatement le microscope et les autres pi ces et installez les sur une table un bureau ou toute autre surface plane Retirez l emballage plastique prot geant le microscope Retirez le papier de protection de la platine 5 Retirez les quatre objectifs 4 de leur emballage D vissez les caches du conteneur du filetage des objectifs Vissez l extr mit de l objectif de 4 mm dans l un des trous de la tourelle 12 jusqu ce qu il soit bien serr Il peut tre n cessaire d abaisser la platine 5 en tournant le bouton de mise au point grossi re 3 Ensuite tournez la tourelle sur la prochaine ouverture et vissez tour de r le les autres objectifs dans les trous restants guapa la tA m e Vous tes maintenant pr t utiliser votre microscope Fonctionnement du microscope Utilisation du miroir illuminateur Votre microscope est quip d un miroir illuminateur int gr plan et concave qui vous permet d clairer l chantillon par dessous en r fl chissant une source externe de lumi re lumi re indirecte du soleil lumi re de la piece d une lampe etc sur la platine Le miroir poss de une surface plane sur laquelle il est vous est facile de voir v
107. us pouvez maintenant faire une mise au point et observer l chantillon mais vous devez n anmoins prendre certaines pr cautions pour ne pas endommager la lame porte objets ou l objectif Votre microscope est quip d une but e de s curit 9 qui vous permet de r gler le trajet de la cr maill re sur le dispositif de mise au point Cette but e est destin e viter tout contact accidentel de l objectif et de la lame porte objets afin de ne pas briser la lame ou de rayer l objectif Pour r gler le trajet sur le m canisme de mise au point 1 2 3 Relevez l objectif en tournant le bouton de mise au point 3 vers l arri re sens horaire pour l loigner de la platine 5 D vissez la vis d arr t 9 de la but e de s curit de la cr maill re sur environ 2 3 de la longueur Tournez la tourelle 12 jusqu ce que l objectif 40x soit au dessus de l chantillon Abaissez l objectif sur la lame porte objets jusqu ce que l extr mit de l objectif se trouve l g rement au dessus de la lame Veillez ne pas toucher la lame porte objets avec l objectif Vissez la vis de s curit 9 vers le haut jusqu ce qu elle butte contre le m canisme de mise au point Tournez le contre crou molet vers le haut pour bloquer la vis de s curit en position Mise au point Maintenant que la lame porte objets est plac e directement sous l objectif utilisez le bouton de mise au point grossi re 3 pour effectuer la mis
108. usbreitet um das gesamte Sichtfeld bei der Betrachtung zu beleuchten 2 W hrend Sie den Kondensor absenken um das Licht auszubreiten oder zu einer Objektivlinse mit gr erer Vergr Berung wechseln erscheint das Bild abgedunkelt Offnen Sie die Apertur der Irisblende um mehr Licht hereinzulassen Offnen und Schliefen des Diaphragmas erm glicht eine Reliefansicht der Probe und erm glicht die Anderung der Sch rfentiefe der betrachteten Probe Verwendung eines Filters Um verschiedene Detailstufen darzustellen k nnen Sie mit einer nderung der Farbe der Hintergrundbeleuchtung der Probe experimentieren Um die Beleuchtungsfarbe zu ndern setzen Sie den Blaufilter im Lichtpfad oben in der elektrischen Beleuchtung ein Es kann sein dass Sie neu fokussieren m ssen indem Sie den Feintriebknopf 11 leicht justieren um ein optimales Bild zu erhalten Ersatz der Lampe der elektrischen Beleuchtung Auswechseln einer defekten Lampe l qu e Daumenschraube Abb 3g 12 Nehmen Sie die Daumenschraube an der Leuchte heraus indem Sie sie gegen den Uhrzeigersinn drehen Wenn Sie das Fach ffnen sehen Sie die 20 Watt Wolframgl hbirne Entfernen Sie die Birne indem Sie sie leicht nach unten dr cken und gegen den Uhrzeigersinn drehen Dann l sst sie sich entfernen Richten Sie die Stifte der neuen Gl hbirne mit den Schlitzen in der Lampenfassung aus dr cken Sie sie ein und drehen Sie sie im Uhrzeigersinn b
109. utifs ou indirects auquel cas les exclusions et limites ci dessus ne vous concernent pas n cessairement Cette garantie vous confere des droits juridiques pr cis et vous pouvez b n ficier d autres droits variables selon votre pays Celestron se r serve le droit de modifier ou interrompre sans notification pr alable tout mod le ou type de microscope En cas de probl mes de garantie ou pour toute assistance concernant l utilisation de votre microscope contactez Celestron Technical Support Department 2835 Columbia Street Torrance CA 90503 U S A T l 310 328 9560 Fax 310 212 5835 www celestron com Du lundi au vendredi de 8h 16h HNP Cette garantie remplace toutes les autres garanties de produit REMARQUE Cette garantie s adresse aux clients am ricains et canadiens qui ont achet ce produit aupr s d un revendeur autoris Celestron aux Etats Unis ou Canada La garantie hors des Etats Unis et du Canada n est valable que pour les clients ayant achet le produit aupres d un distributeur ou revendeur autoris Celestron dans un pays donn et ce sont ces personnes qu il faudra contacter pour tout service de garantie 19 CELESTRON Celestron 2835 Columbia Street Torrance CA 90503 U S A T l 310 328 9560 Fax 310 212 5835 Web www celestron com Copyright 2007 Tous droits r serv s Les produits ou instructions peuvent changer sans notification ou obligation Imprim en Chine 10 04 07
110. utilice el espejo para concentrar la luz solar directa a trav s del microscopio ya que puede ser muy da ina y da ar la vista 2 Si se utiliza de noche o adentro sin luz solar puede usar una l mpara de escritorio cercana una l mpara de mesa u otra fuente luminosa para reflejar la luz sobre el esp cimen Para controlar la cantidad de luz que se refleja en el esp cimen 1 Use el lado c ncavo del espejo para concentrar m s luz en el portaobjetos El lado c ncavo concentrar mas luz en el esp cimen pero concentrar un haz mucho m s peque o haci ndolo m s sensible para regular 2 Si no puede regular el espejo para que ilumine el esp cimen correctamente puede cambiar la posici n del espejo inclinando el brazo 10 hacia atr s Ajuste del ngulo del brazo La posici n normal de observaci n es 0 Sin embargo tambi n se puede hacer desde cualquier ngulo de 0 a 45 Para cambiar el ngulo de observaci n 1 Sostenga la base con una mano 7 2 Despu s con la otra mano incline el brazo 10 movi ndolo hacia adelante o hacia atr s hasta el ngulo de observaci n deseado Observaci n del esp cimen Cuidadosamente coloque un portaobjetos debajo de las presillas a resorte de la platina 8 y centre el esp cimen directamente sobre el agujero en el centro de la platina 5 Ahora est listo para enfocar y observar el esp cimen pero primero debe tomar ciertas precauciones para no da ar el portaobjetos o el obje
111. uz sobre el esp cimen que el lado plano Para iluminar el esp cimen 1 Si tiene luz natural incline el espejo 6 y refleje la luz indirecta desde la parte de abajo de la platina 5 Advertencia Nunca utilice el espejo para concentrar la luz solar directa a trav s del microscopio ya que puede ser muy da ina y da ar la vista 2 Si se utiliza en la noche o adentro sin luz solar puede usar una l mpara de escritorio cercana una l mpara de mesa u otra fuente luminosa para reflejar la luz sobre el esp cimen Para controlar la cantidad de luz que se refleja en el esp cimen 1 Use el lado c ncavo del espejo para concentrar m s luz en el portaobjetos El lado c ncavo concentrar m s luz en el esp cimen pero concentrar un haz mucho m s peque o haci ndolo m s sensible para regular 2 Si no puede regular el espejo para que ilumine el esp cimen correctamente puede cambiar la posici n del espejo inclinando el brazo 10 hacia atr s vea la secci n Ajuste del ngulo del brazo 3 Tambi n puede controlar la cantidad de luz con el condensador y el diafragma vea la secci n Ajuste de la luz Ajuste del ngulo del brazo La posici n normal de observaci n es 0 Sin embargo tambi n se puede hacer desde cualquier ngulo de 0 a 60 Para cambiar el ngulo de observaci n 1 Sostenga la base con una mano 7 2 Conlaotra mano incline el brazo 10 movi ndolo hacia adelante o hacia atr s hasta el ngulo d
112. ve lens into one of the holes on the nosepiece 12 until finger tight It may be necessary to lower the stage 5 by turning the coarse focus knob 3 Now turn the nosepiece to the next opening and thread each of the remaining objective lenses into the remaining holes You are now ready to use your microscope Microscope Operation Using the Illuminator Mirror Your microscope has a built in plano concave illumination mirror which allows you to illuminate the specimen from the bottom by reflecting an external light source indirect sunlight room light lamp etc to the stage The mirror has a flat side you can easily see your reflection on the flat surface and a concave side The concave side will concentrate more light onto the specimen than the flat side To illuminate a specimen If it is daylight tilt the mirror 6 and reflect indirect sunlight through the bottom of the stage 5 Warning Never use the mirror to focus direct sunlight through the microscope as this can be very harmful and may damage your eyes If viewing at night or indoors away from sunlight you can use a nearby desk lamp table lamp or other light source to reflect light onto a specimen 1 To control the amount of light reflecting onto the specimen 1 Use the concave side of the mirror to focus more light on the slide The concave side will concentrate more light onto your specimen but will focus a smaller beam of light making it more sensitive to adjust
113. vec l objectif de plus faible puissance en passant progressivement des puissances sup rieures 11 Regardez dans l oculaire en tournant le bouton de mise au point grossi re 3 jusqu ce que l chantillon soit visible Il peut tre n cessaire de r gler l g rement les boutons de la platine Figure 4h pour centrer l chantillon dans le champ de vision Avertissement Lors de la mise au point veillez ne pas relever la platine chantillons afin d viter tout contact entre la lame porte objets et l objectif Non seulement vous risqueriez de briser votre lame porte objets mais vous pourriez rayer l objectif 12 Pour finir r glez le bouton de mise au point fine 11 jusqu obtenir l image la plus nette pour votre ceil Avertissement Ne jamais tourner simultan ment les deux boutons de mise au point fine dans des directions oppos es sous peine d endommager le m canisme de mise au point Conseil utile Pour l observation d un chantillon avec un objectif de 100x il est possible d am liorer la r solution en placant une petite goutte d huile immersion entre l chantillon et l objectif Avec les lames porte objets que vous pr parez vous m me couvrez toujours l chantillon avec une fine lamelle de verre et mettez l huile sur ce verre Ne mettez pas l huile directement sur l chantillon 16 R glage de l clairage Les chantillons devront tre clair s diff remment en fonction de leur taille de leur paisseu
114. volver 12 bis sich die 40x Linse ber der Probe befindet 7 Lassen Sie die Objektivlinse auf den Objekttr ger herab bis die Spitze der Linse sich kurz ber dem Objekttr ger befindet Aufpassen dass die Objektivlinse nicht mit dem Objekttr ger in Kontakt kommt Drehen Sie die Anschlagschutzschraube 9 nach oben bis sie am Fokusmechanismus auftrifft 9 Drehen Sie die R ndelmutter nach oben um die Anschlagschutzschraube in dieser Stellung zu arretieren 10 ve Objekttisch i Hinweis Der obere Objekttischknopf nimmt eine Bewegung in der X Achse vorw rts und r ckw rts vor w hrend der untere Objekttischknopf eine Bewegung in der Y Achse von einer Seite zur anderen bewirkt Eine Vernier Skala Objekttischkn pfe auf beiden Achsen erm glicht die genaue Markierung und Replikation eines Objekts im Sichtfeld zu dem der Benutzer sp ter eventuell zur ckkommen m chte Abb 3e Tipp Zur Positionierung der Probe direkt unter der Objektivlinse schlieBen Sie die Offnung an der Irisblende siehe Abb 3f bis sie fast vollst ndig geschlossen ist Jetzt m sste ein kleiner Lichtstrahl sichtbar sein der auf den Objekttr ger projiziert wird Nun k nnen Sie die Probe direkt in den Lichtstrahl mithilfe der Objekttischkn pfe bewegen 10 Drehen Sie die Objektivlinsen 4 mithilfe des Revolvers 12 bis das 4x Objektiv sich direkt ber der Probe befindet Immer mit dem Objektiv mit der kleinsten Vergr erung beginnen und
115. y Friday 8AM 4PM PST This warranty supersedes all other product warranties NOTE This warranty is valid to U S A and Canadian customers who have purchased this product from an Authorized Celestron Dealer in the U S A or Canada Warranty outside the U S A and Canada is valid only to customers who purchased from a Celestron Distributor or Authorized Celestron Dealer in the specific country and please contact them for any warranty service 19 CELESTRON MANUAL DE INSTRUCCIONES e Modelo de laboratorio N 44100 Modelo de laboratorio N 44102 e Modelo avanzado N 44104 Modelo avanzado N 44106 y Indice Introducciono ee ee geess EE Ed EE eg Modelo de laboratorio N 44100 csssssssccccccssessssccvccesessssseccceseso Modelo de laboratorio N 44102 cccsssssssccccccssessssccccesessssseccceseso Modelo avanzado N 44104 sssssscccccccsssssscccccsssssssccccessesssssescecO Modelo avanzado N 44106 ENEE EEN ENNEN ENEE EEN NNN EEN NA a a veel A Cuidado y mantenimiento ee NENNEN NNEN Gio korda NNN aeneo vex DY sese LS 2 Garat HD Introducci n Felicitaciones por haber adquirido un microscopio Celestron Su microscopio es un instrumento ptico de precisi n fabricado con materiales de la m s alta calidad para asegurarle durabilidad y una larga vida til Est dise ado para que pueda disfrutarlo al m ximo con un m nimo de mantenimiento E

Download Pdf Manuals

image

Related Search

Related Contents

EC type-examination certificate UK/0126/0182  Player Operation User's Manual  Olympus VT484501 User's Manual  USB 3.0 VGA Adapter www.lindy.com  PDF 876KB - タカショーCAD・取扱説明書データ ダウンロード  Toro Multi Pro WM (41240) Specifications  User Manual Safety Precaution  Sencor SFP 5661 HELLO KITTY  形 FQ-S  ダウンロード(PDF 6.45 MB)  