Home

EnerGenie EG-PMS surge protector

image

Contents

1. 4 Gembird www gembird ua 044 4510213 50 All brands and logos registered trademarks of their respective owners
2. _ 1 TEPMIHY 2
3. 2 3 Ha 4
4. fauts dus une mauvaise utilisation abus ou les effets externes chute choc p n tration de l eau la poussi re etc Les pi ces d usure par exemple les piles rechargeables sont exclus de la garantie D s r ception de la marchandise sous garantie le SAV de Gembird Europe BV se r serve le droit de choisir entre le remplacement des produits d fectueux ou de d livrer un avoir Le montant d avoir sera toujours calcul e sur la base de la valeur actuelle du march des produits d fectueux Gembird Europe B V Wittevrouwen 56 1358CD Almere The Netherlands www gembird nl support support gmb nl 33 0 251 404849 Prix d appel depuis telephone fixe Pays Bas 0 15 euro min Prix d appel depuis telephone mobile autre pays selon operateur 49 All brands and logos are registered trademarks of their respective owners EG PMS PROGRAMMABLE USB SURGE PROTECTOR energenie 1
5. make sure the EG PMS is and indicators are not lit connected to the power supply and the rocker switch is switched on Check the grounding of EG PMS If inductive load like florescent lamps Software reports Device I O motors are connected to EG PMS it is request error after switching recommended to use an extra USB hub to connect EG PMS to the managing computer Do not power EG PMS off when the hardware timer schedule is active Press the Silence button every push will reduce the delay with one minute Timer schedule is delayed 45 All brands and logos are registered trademarks of their respective owners z genie EG PMS PROGRAMMABLE USB SURGE PROTECTOR lt gt WALTEK SERVICES Declaration of Compliance The following product has been tested by us with the listed standards and found in compliance with the European directive LVD 73 23 EEC amended by 93 68 EEC It is possible to use marking to demonstrate the compliance with this LVD Directive Reference No WT05121031 APPLICANT Gembird Electronics Ltd Room 1709 News Building 2 Shennan Zhong Lu Shenzhen China MANUFACTURER GEMBIRD ELECTRONICS ZHUHAI CO LTD 5 Floor Building 1 Pingdong Road 2 Nanping Industry Park Zhuhai Guangdong China TYPE OF EQUIPMENT Socket with surge protection MODEL NO SIS PMx TECHNICAL DATA 220 250V 10A Test Standards 1 60884 1 2002 Plugs and socket outlets for household and similar purpose
6. s leeg zijn en dus geen stroom meer kunnen leveren Let op de batterijen accu s dienen onbeschadigd ingeleverd te worden Gooi dit product niet weg in uw vuilnisbak Dit kan zowel het milieu als de menselijke gezondheid schade toebrengen Informatie over het inleveren van dit product kunt u inwinnen bij uw gemeentelijke vuilnisdienst of andere geautoriseerde instelling in uw buurt EG PMS PROGRAMMABLE USB SURGE PROTECTOR Entsorgungshinweise Werfen Sie dieses Ger t nicht in den Hausm ll Unsachgem e Entsorgung kann sowohl der Umwelt als auch der menschlichen Gesundheit schaden Informationen zu Sammelstellen f r Altger te erhalten Sie bei Ihrer Stadtverwaltung oder einer autorisierten Stelle f r die Entsorgung von Elektro und Elektronikger ten Traitement des dechets Ne jetez pas cet appareil dans les dechets domestiques Un traitement inapproprie peut tre dommageable l environnement et la sant humain Vous trouvez des informations sur les centres de rassemblement des appareils vieux chez l administration municipale ou chez un centre autoris pour le traitement des appareils lectriques ou lectroniques 47 All brands and logos are registered trademarks of their respective owners energente WARRANTY CONDITIONS The warranty period is 36 months and begins with the sale to the end user The receipt must clearly list the date of purchase and the part number in addition it should be pri
7. Switch printer on off Path CAWINDOWS system32 spool PRINTERS m On placing Delay on placing On removal Delay on removal Enabled e To remove the event select it and click the Remove button see Figure 13 above You can select multiple events using Ctrl and Shift keys You can also remove all events by clicking the Clear button HINT Use the popup menu which can be activated by the right mouse button click over the table 33 All brands and logos are registered trademarks of their respective owners z genie EG PMS CRETE PROGRAMMABLE USB SURGE PROTECTOR 5 Power Manager advanced features The following information is for advanced users which wish to have full access to the advanced features of EG PMS Click the Advanced features button available from the Settings window see section 4 1 above The following window will then appear see Figure 17 below Figure 17 Advanced features Voltage alarm Disable alarm log window Disable device beeper ver o 8 when slam goesoff LER Device sharing Device timer tuning 34 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR 5 1 Processing the alarms Whenever the actual measured voltage on the manageable socket deviates from the status set by your switching tasks it is called a Voltage alarm The Voltage alarm can for example be caused by a blackou
8. the required action e To switch the socket on off on the Windows shutdown sleep check the On Windows shutdown checkbox and choose the required action 17 All brands and logos are registered trademarks of their respective owners z genie EG PMS CRETE PROGRAMMABLE USB SURGE PROTECTOR 4 2 Setting up the hardware schedule Using the Hardware schedule button available from the Settings window you can create the hardware timer schedule see Figure 6 below To add a new record click the Add button Figure 6 Action Timeout 10 27 19 08 2010 Switch ON 3 minutes left 20 27 19 08 2010 Switch OFF Every 1 day Loop 18 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR e The window Add entry will appear see Figure below In the dialog box specify the required time and the action Figure 7 Add entry Entry Time 1035 88 12082010 Schon Switch ON e To edit the record select it and click the Edit button or just double click on the entry The window Edit entry will appear see Figure 8 below 19 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR Figure 8 Edit entry Entry Time 1025 88 19 08 2010 Actor Switch e To remove the record select it and click the Remove button see Figure 6 above You
9. 3 Audible signals e Long beep will be heard after EG PMS is successfully connected to the computer USB port after the self test e Short beep will be heard by switching the manageable sockets on and off e Continuous beeps hardware event schedule is lost for example if the power supply was cut for a long time These beeps can be stopped by pressing the Silence button see Figure 1 above e Alarm beep will be heard if the managing command cannot be executed E g if there is a command to switch the socket on but EG PMS is disconnected from the power supply The alarm will be heard every second during a minute after that every 8 seconds Let EG PMS execute the command e g switch EG PMS on to get rid of the alarm beeps 10 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR 3 Installation e It is strongly recommended to avoid damp or wet places for installation EG PMS should be connected to the European AC wall socket of the standard DIN 49 440 3 1 Getting started e Connect EG PMS to the wall socket first and then to the USB socket of the manageable computer or vice versa 5 can now be switched on and off by means of the rocker switch Z e Two the first and the last sockets of EG PMS are marked with the symbol c These two sockets are switched on and off by means of the Main rocker switch Z
10. Enabled opecify the path to the folder you would like to monitor using the Browse button or typing it manually in the Path name field Specify the File name mask using wildcard characters Check then On placing and or On removal checkboxes and select the event and delay NOTE The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder The On removal event will take place when the last file matching the specified file name mask is removed from the specified folder 31 All brands and logos are registered trademarks of their respective owners ge nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR HINT Your device is an advanced standby killer Use the Add folder button to assign c system32 spool printers folder to switch your printer on whenever you start printing and to switch it off again whenever you are ready with printing HINT If you have several printers connected to the same computer we suggest moving default spool directory of each printer to a separate location e To edit the event select it and click the Edit button or just double click on the event see Figure 13 above The Edit file event window will appear see Figure 16 below 32 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR Figure 16 Edit file event Event Title
11. MMABLE USB SURGE PROTECTOR Figure 14 Add program event Evi Dj Un run Switch On exit Switch OFF Enabled Specify the application title and path to it using the Browse button or typing it manually in the Title and Path name fields If you use the Browse button you can also select a shortcut to the application In this case the application title and path name will be taken automatically 29 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR via the shortcut if possible After you have specified the application check On run and or On exit and choose the event switch on or off NOTE The On run event will take place when the first window of the selected application is opened The On exit event will take place when the last window of the application is closed HINT Your device is an advanced standby killer Using this feature you can for example switch your scanner on off whenever Photoshop is started closed e To add a new file event click the Add folder button see Figure 13 above The Add file event window will appear see Figure 15 below 30 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR Figure 15 Event Banane 7 B v On removal Delay on removal n
12. USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EG PMS PROGRAMMABLE USB SURGE PROTECTOR ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR PROGRAMMABLE SURGE PROTECTOR PROGRAMMIERBARE STECKDOSENLEISTE PROGRAMMEERBARE STEKKERDOOS PARASURTENSEUR PROGRAMMABLE c 2 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR Contents 1 Introduction 4 1 1 Features 4 1 2 Specifications 6 1 3 Hardware requirements 6 1 4 Package contents 7 2 Indicators and controls of EG PMS 8 2 1 Side panel 9 2 2 Indicators 10 2 3 Audible signals 10 3 Installation 11 3 1 Getting started 11 3 2 Power Manager installation 13 4 Power Manager software 13 4 1 Managing EG PMS 13 4 2 Setting up the hardware schedule 18 4 3 Setting up the software schedule 23 4 4 Setting up application events 27 5 Power Manager advanced features 34 5 1 Processing the alarms 35 5 2 Managing EG PMS via your own software 36 6 Troubleshooting 45 3 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR 1 Introduction Congratulations with your purchase of
13. and cannot be managed by the computer so they are called non manageable sockets in this manual e If EG PMS is switched on then the red indicator POWER is lit In this case both non manageable sockets are now live and connected to the power supply 11 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR e The sockets Socket 1 Socket 2 Socket 3 and Socket 4 can be managed or pre programmed by computer via USB They are called manageable sockets in this manual e The manageable sockets of EG PMS can be programmed to be on or off The current status of each manageable socket is represented by the corresponding indicator which will be lit if socket has power to it e If the Main rocker switch Z see figure 1 above is turned off then the manageable sockets cannot be switched on by either Power manager software or the hardware schedule As soon as you turn the Main rocker switch 2 on then the Power manager software or the hardware schedule will be able to turn the manageable sockets on and off e To protect the connected devices from possible high current and short circuit EG PMS is equipped with the automatic circuit breaker NOTE If the total power consumption or peak power of the devices connected to EG PMS exceeds 2200 Watts the circuit breaker may power EG PMS off In this case please remove the excessive load first and then press th
14. can select multiple entries using Ctrl and Shift keys You can also remove all entries from the schedule by clicking the Clear button see Figure 6 above e To repeat your event for example if you want to perform the same events every day use the Loop button see Figure 6 above and specify the loop time period in the Edit loop period window see Figure 9 below 20 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR Figure 9 Edit loop penad Loop period Petar schede eve e After the schedule record has been created click the Apply button see Figure 6 above to save the hardware timer schedule changes In case of incorrect entries these will be highlighted and an error message will appear Click the Apply button again after correcting all the errors e Use Sync button see Figure 6 above to synchronize device timer with PC clock Note that after synchronization past entries will be removed from the schedule HINT Use the popup menu see Figure 6 above which can be activated by the right mouse button click over the table The following are the rules for creating a correct schedule 21 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR The new event time should be in the future There can not be a duplicate entry The total quantity of events can n
15. e Circuit breaker button to restore the power supply see figure 2 above 12 All brands and logos are registered trademarks of their respective owners ener rgenie EG PMS PROGRAMMABLE USB SURGE PROTECTOR 3 2 Power Manager installation e Insert the Power Manager CD into a PC CD ROM drive for any reason the automatic setup does not work then open CD ROM drive in the My Computer window and launch SETUP EXE from the CD e Follow instructions of the installation software 4 Power Manager software The Power Manager software is designed to support not only EG PMS but also other products of Energenie family After a successful installation a socket icon will appear in your system tray 4 1 Managing EG PMS Double click on the socket icon in the system tray or select Open from the popup menu see Figure 3 below 13 All brands and logos are registered trademarks of their respective owners ener rgenie EG PMS PROGRAMMABLE USB SURGE PROTECTOR Figure 3 1 BT devices Be Shared devices e LAN devices w Enable autoupdate Help About X Exit You will get then the window of the main control panel shown on the Figure 4 below 14 All brands and logos are registered trademarks of their respective owners z genie EG PMS CRETE PROGRAMMABLE USB SURGE PROTECTOR Figure 4 Power Manager eT EM ANACER Double click over each socket will switc
16. egistered trademarks of their respective owners z genie EG PMS eners es PROGRAMMABLE USB SURGE PROTECTOR Figure 10 Software schedule Switch ON time Switch OFF time Perform task every Comment 10 40 19 08 2010 20 38 13 08 2010 1 day e To add a new task click the Add button The Add task window will appear see Figure 11 below 24 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR Figure 11 Perform task every Comment Enabled In the Add task window check Switch ON time and or Switch OFF time checkboxes and specify the time to switch the socked on and or off If you want the same event to be performed periodically check Perform task every checkbox and specify the time interval You can also add remarks about the task in the Comment field To disable the task uncheck the Enabled checkbox and to enable the task again re check the checkbox 25 All brands and logos are registered trademarks of their respective owners z genie EG PMS 2 PROGRAMMABLE USB SURGE PROTECTOR To edit the task select it see Figure 10 above and click the Edit button or just double click on the task The Edit task window will appear see Figure 12 below Figure 12 Edit task Task Perform task every Comment Enabled 26 All brands and logos are registered trademarks of their respective owners ge n
17. h it on and off green color means the socket is switched off red color means the socket is switched on Click the Settings button for each socket to access the Settings dialog box see Figure 5 below 15 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR Figure 5 Device Device2 Socket Socket3 System tray Hot Key Windows startup and shutdown events Hardware schedule On Windows startup Switch ON Software schedule Application events On Windows shutdown Switch OFF Advanced features POWERMANAGER Close You can choose a different device and another socket from the Device and Socket drop down list boxes 16 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR e 115 possible to give a name to the device and socket for example Printer or Scanner using the Rename button e Check the System tray checkbox if you want to put the icon of the socket into the system tray You can choose the icon from drop down list box Such icon is a fast way to switch the device connected to the socket on off or check the device status e You can also assign a hot key to switch the socket on off Check the Switch ON and Switch OFF checkboxes and specify the hot keys e To switch the socket on off on Windows startup wake up check the On Windows startup checkbox and choose
18. ie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR e To remove the task select it and click the Remove button see Figure 9 above You may select multiple tasks using Ctrl and Shift keys You can also remove all tasks by clicking the Clear button HINT Use the popup menu which can be activated by the right mouse button click over the table see Figure 10 above 4 4 Setting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down You can also associate switching the sockets off or on with placement and removal of particular files in certain folders To use this feature push Application events button available from the Settings window see section 4 1 above Figure 5 You will get the following window see Figure 13 below 27 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR Figure 13 Application events Title Path name On run On exit Switch scanner on off END OS ersten exe Switch OM Switch OFF O Switch printer on off CAWINDOW S syshem3e spoolKPRINTERS Switch ON Switch OFF PEN cm e To add a new program event click the Add app button The Add program event dialog will appear see Figure 14 below 28 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRA
19. ks of their respective owners ge nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR 1 4 Package contents The package contains EG PMS e User manual e USB cable CD with Power Manager software for Windows 7 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR 2 Indicators and controls of EG PMS Side panel Indicator Main rocker switch Z POWER Non manageable socket RN Indicator Socket 4 Indicator Socket 3 Indicator Socket 2 Indicator Socket 1 I BN Socket 4 N 2 Socket 3 i NL Non manageable socket Silence button to suppress beeps 8 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR 2 1 Side panel Figure 2 Circuit breaker Power cord 9 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR 2 2 Indicators e Main rocker switch Z see Figure 1 above is lit this means that EG PMS is connected to the power supply and active e Power indicator see Figure 1 above is lit this means that the non manageable sockets marked with the sign S are switched on e The indicator Socket 1 2 3 4 see Figure 1 above is this means that this particular socket is switched on 2
20. ls are not desirable then set the option Disable device beeper in the Advanced features window see Figure 17 above Another useful option available from the Advanced features window see Figure 17 above is the tuning of the device timer Synchronization of the device timer with the managing PC timer is available by using Sync button from the Time schedule window see Figure 6 above If the device timer has a certain daily error it can be corrected using this tuning option Push Device timer tuning button to access the Device time tuning window see Figure 23 below 41 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR Figure 23 Device time turing Tuning options Specify timer correction to be applied ever 24 hours Correction 0 seconds Enter the correction value in seconds which will be applied every 24 hours and push OK button 5 4 Managing EG PMS via your own software To let you switch the sockets from your own applications the following command line interface syntax is supported pm exe on off device name socket name Examples 42 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR e C Program Files Energenie Power Manager pm exe on EG PM socket e E Utils PM3 pm exe off My EG PM Table lamp e Execute pm e
21. n your computer press the button Device sharing in the Advanced features window see Figure 17 above The window Device sharing will appear see Figure 19 below 36 All brands and logos are registered trademarks of their respective owners energe nie EG PMS PROGRAMMABLE USB SURGE PROTECTOR Figure 19 Device sharing Sharing options Share this device via network Set the checkbox Share this device via network if you want to enable the network access to the device via this PC To prevent unauthorized access to the device enter the access password in the field Password NOTE The port 6100 should be open Contact your LAN administrator for further details To be able to use this shared EG PMS on a client PC choose Shared devices from the Main menu see Figure 3 above You will get the following window see Figure 20 below 37 All brands and logos are registered trademarks of their respective owners z genie EG PMS CRETE PROGRAMMABLE USB SURGE PROTECTOR Figure 20 Hostname Device name Status To add a new remote device press the Add button You will see the window Add network device see Figure 21 below 38 All brands and logos are registered trademarks of their respective owners z ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR Figure 21 Add network device Network device Hostname Device name Password Enabled Enter the network name of the server which is connected
22. nted Keep the receipt for the entire warranty period since it is required for all warranty claims During the warranty period the defective items will be credited repaired or replaced at the manufacturer s expense Work carried out under the warranty neither extends the warranty period nor starts a new warranty period The manufacturer reserves the right to void any warranty claim for damages or defects due to misuse abuse or external impact falling down impact ingress of water dust contamination or break Wearing parts e g rechargeable batteries are excluded from the warranty Upon receipt of the RMA goods Gembird Europe B V reserves the right to choose between replacement of defective goods or issuing a credit note The credit note amount will always be calculated on the basis of the current market value of the defective products Gembird Europe B V Wittevrouwen 56 1358CD Almere The Netherlands www gembird nl support support gmb nl Tel 31 36 5211588 0900 4362473 inside The Netherlands 0 15 p m mobile costs not included EG PMS PROGRAMMABLE USB SURGE PROTECTOR GARANTIE BEDINGUNGEN Die Garantie betr gt 36 Monate ab Verkaufsdatum an den Endverbraucher Das Kaufdatum und der Ger tetyp sind durch eine maschinell erstellte Kaufquittung zu belegen Bitte bewahren Sie Ihren Kaufbeleg daher f r die Dauer der Garantie auf da er Voraussetzung f r eine eventuelle Reklamation ist Innerhalb der Garantiezeit
23. ot exceed 16 per socket The total quantity of events also depends on the total execution period of the schedule e interval between the present and the last entry can not exceed 180 days e Without loop the total execution period of the schedule can not exceed 215 days e Loop period can not exceed 180 days NOTE If the device is powered off the hardware schedule is still in the device memory and will be resumed when the power supply is restored However the whole schedule will be then delayed with the power cutoff time EG PMS will then start beeping indicating the hardware schedule problem Press Silence button once to turn the beeps off if you don t care about the accuracy of your schedule You can also adjust the schedule eliminating the delay Every time you press the Silence button again after the beeps were off the schedule will be adjusted with one minute Alternatively create and upload a new schedule using the Timer schedule dialog box 22 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR 4 3 Setting up the software schedule Using the Software schedule button available from the Settings window you can create the software timer schedule see Figure 10 below NOTE the software timer schedule will only be executed if the managing computer is on and the Power Manager is launched 23 All brands and logos are r
24. s Part 1 General requirements The referred test report s show that the product complies with standard s recognized as giving presumption of compliance with the essential requirements in the above listed EU Directive s Other relevant Directives have to be observed After preparation of the necessary technical documentation as well as conformity declaration the CE marking as shown below be affixed on the 9 CE lt Date Apr 14 2006 statement is based on single evaluation of one sample of above mentioned products does not imply an assessment of the whole production Add 8C West Tower Aid Building No 5003 Binhe Rd Futian District Shenzhen China Tel 86 755 83551033 83551756 Fax 86 755 83552400 www waltek com on E mail info wattek com cn 46 All brands and logos are registered trademarks of their respective owners energente Waste disposal Do not deposit this equipment with the household waste Improper disposal can harm both the environment and human health For Information about waste collection facilities for used electrical and electronic devices please contact your city council or an authorized company for the disposal of electrical and electronic equipment Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor te zorgen dat de batterijen accu
25. scanner on when want to scan or switch my printer off whenever exit Windows e Real time Voltage monitor provides information about the actual status of each manageable socket on or off This information can be further utilized in various ways e g to check the proper execution of the switching commands e The unit can be assigned a network name as a shared LAN resource and can be afterwards accessed and managed from anywhere within the local area network or Internet provided the managing computer is switched on 5 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR 1 2 Specifications Input voltage 220 230 VAC 50 60 Hz Maximum load 10 A Maximum power consumed by EG PMS 2 5 W Built in power supply Hardware schedule features Maximum number of independent hardware schedule events 16 per socket Time interval between the events from 1 minute to 180 days Timer accuracy no more than 2 seconds error per day providing power is always present Otherwise there can be an additional up to 2 seconds error per each power off Working temperature range from 10 to 40 C Dimensions 378 x 98 x 55 mm Net weight 1 0 kg 1 3 Hardware requirements Computer running Windows 2000 XP Vista or Windows 7 is required for using the Power Manager software One free USB port 6 All brands and logos are registered trademar
26. schade of gebreken die ontstaan zijn door oneigenlijk gebruik misbruik of invloeden van buitenaf vallen stoten water stof vuil of breken Slijtagegevoelige onderdelen b v batterijen zijn uitgesloten van garantie Bij ontvangst van de RMA goederen behoudt Gembird zich het recht om te kiezen tussen vervanging van de defecte waren of het uitgeven van een kreditnota Het bedrag van de kreditnota zal altijd gecalculeerd zijn op basis van de huidige marktprijs voor het defecte produkt Gembird Europe B V Wittevrouwen 56 1358CD Almere The Netherlands www gembird nl support support qmb nl Tel 0900 4362473 0 15 p m binnen Nederland Exclusief mobiele telefoonkosten EG PMS PROGRAMMABLE USB SURGE PROTECTOR CONDITIONS DE GARANTIE Garantie est de 36 mois a partir de la date d achat de l utilisateur final Le talon de garantie doit enumerer clairement la date d achat et le type d appareil Conservez le d achat pendant toute la dur e de la garantie car elle est n cessaire pour toute r clamation Au cours de la p riode de garantie tous les d fauts doivent tre remplace aux frais du fabricant soit par la r paration ou la remplacement de la piece d fectueuse ou l ensemble du produit Les travaux effectu s sous garantie ne prolongent pas la p riode de garantie ni ne commencent pas une nouvelle p riode de garantie Le fabricant se r serve le droit d annuler toute demande de garantie pour les dommages ou d
27. t and will be resolved after power returns The Voltage alarm can also be triggered if for any reason a switching task could not be carried out switching malfunction Voltage alarms are accompanied with beeps unless Disable device beeper option is activated The default action by an alarm is to record this event into a log file and show a popup Alarm log window see Figure 18 below Figure 18 25 08 2010 19 37 50 Device2 Socket4 Voltage alarm The socket must be switched on but the actual measured voltage is off 25 08 2010 19 38 20 Device2 Socket4 Voltage alarm is resolved 35 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR You might wish to process this situation in a different way e g send an email message somewhere etc e Check the Disable alarm log window checkbox to disable the popup Alarm log window applies to all devices e Check the When alarm goes on checkbox then click the Browser button to select the desired program to be launched whenever a voltage alarm is triggered e Check the When alarm goes off checkbox then click the Browser button to select the desired program to be launched after the alarm status see above is resolved 5 2 Setting up network devices You can declare EG PMS as a shared device on your server and let the other users access it via the server To make EG PMS shared o
28. this Energenie Power Manager Your EG PMS is an advanced surge protector with power management features Four sockets are individually manageable by the computer via USB interface The sockets can be switched on off by a timer schedule by user or different events It is also possible to pre program the unit event timer schedule hardware schedule and then disconnect EG PMS from the managing computer The device can be used as an advanced standby killer 1 1 Features e The main rocker switch enables switching all the sockets on and off e addition to it every manageable socket can be switched on and off via the software control window e The unit can be pre programmed via hardware based schedule The hardware schedule will work even when the managing computer is switched off 4 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners os PROGRAMMABLE USB SURGE PROTECTOR e The unit will keep performing the programmed hardware time schedule even after EG PMS is disconnected from the power for some time e The manageable sockets can then be switched on and off by the schedule simple typical applications could be switch my peripherals on every working day at 8 50 etc e The manageable sockets can also be programmed with Power Manager software to react whenever a certain event occurs Windows or other programs start up shutdown simple typical applications could be switch my
29. to EG PMS in the field Hostname Enter the name of the target EG PMS in the field Device name Enter access password in the field Password To disconnect from the device uncheck the option Enable set this option on again to regain the access To locate the shared device in your local network click the button Find A dialog box Find network device will 39 All brands and logos are registered trademarks of their respective owners z genie EG PMS CRETE PROGRAMMABLE USB SURGE PROTECTOR appear Choose the proper server and then the device and click OK button To edit the network device select it and click the Edit button or just double click on the network device see Figure 20 above The Edit network device window will appear see Figure 22 below Figure 22 Edit network device Network device Hostname Server Device name Device Password 40 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR To remove the network device select it and click the Remove button see Figure 20 above You can select multiple network devices using Ctrl and Shift keys You can also remove all network devices by clicking the Clear button HINT Use the popup menu which is available with the right mouse button click over the table 5 3 Managing device beeper and timer EG PMS produces quite a few audible signals see Section 2 3 above If these signa
30. werden alle M ngel wahlweise durch den Hersteller entweder durch Instandsetzung Austausch mangelhafter Teile oder im Austausch behoben Die Ausf hrung der Garantieleistung bewirkt weder eine Verl ngerung noch einen Neubeginn der Garantiezeit Eine Garantieleistung entf llt f r Sch den oder M ngel die durch unsachgem e Handhabung oder durch u ere Einwirkung Sturz Schlag Wasser Staub Verschmutzung oder Bruch herbeigef hrt wurden Verschlei teile z B Akkus sind von der Garantie ausgenommen GEMBIRD Deutschland GmbH Coesterweg 45 59494 Soest Deutschland www gembird de support support gembird de Tel 49 180 5 436247 0 14 pro Minute aus dem deutschen Festnetz Mobilfunkpreise k nnen abweichen 48 All brands and logos are registered trademarks of their respective owners energente GARANTIE VOORWAARDEN a aa il De garantietermijn bedraagt 36 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan Gelieve de aankoopbon de gehele garantieperiode te bewaren deze is ten alle tijden benodigd voor alle garantie aanspraken Tijdens de garantieperiode zullen alle gebreken verholpen of vervangen worden door de fabrikant d m v reparatie omruiling van het defecte onderdeel of het gehele apparaat Aanspraken tijdens de garantieperiode leiden niet tot verlenging hiervan Garantieaanspraak vervalt bij
31. xe with info key pm exe info to get the complete information about the status of the current devices For each of the connected devices the following information will then be provided and placed into nfo ini file in the Power Manager folder e DeviceName the user specified device name Socket name where is replaced by a certain socket number the user specified socket name Socket SwitchState where is replaced by a certain socket number TRUE when the socket is switched on FALSE when the socket is switched off SocketZVoltageState where is replaced by a certain socket number TRUE when voltage presence on the socket is detected FALSE when there is no voltage on the socket Example 43 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR NOTE Each use of this command line option totally overrides the data in Info ini file NOTE Power Manager should be active 44 All brands and logos are registered trademarks of their respective owners ge nie EG PMS eners PROGRAMMABLE USB SURGE PROTECTOR 6 Troubleshooting The load connected to the device is too The circuit breaker is activated high some of the devices connected to tripped the EG PMS should be disconnected and the circuit breaker should be reset The switching command is not There is no power supply to the EG PMS carried out the rocker switch Please

Download Pdf Manuals

image

Related Search

Related Contents

(Lote 22.- Carpinter\355a de madera y varios  Sanyo MPX-CD4 Musical Instrument User Manual  Wireless Sensor Networks: Development of an Environmental Data  SPECsfs2008 User's Guide  Philips Norelco Bodygroom 3100 BG2034  Samsung PS-42D4S User Manual  SMART LINE  Benutzerbestimmbare Informationsflusskontrolle (SU)  Kärcher T 9/1 Bp  Ver.1.00  

Copyright © All rights reserved.
Failed to retrieve file