1. Information regarding transmittal from remote sensor to display unit e It is very important that you activate the batteries in the remote sensor BEFORE activating the batteries in the display unit As soon as the batteries are inserted in the remote sensor it will begin sending thermo measurement data The display unit will start receiving data as soon as its batteries are activated Before mounting the sensor at its final position we strongly recommend ensuring the successful communication which means checking the data on the display unit To do so place the sensor within a radius of approx one meter of the display unit Make sure there are no sources of disturbance in the vicinity of the two devices e As soon as the measurement data appears on the display unit you may mount the sensor within the maximum distance of 30m at a position of your choice REMARK e Before operating the device wait until data from the sensor appears on the display unit e The effective receiving radius may be limited by building structures e g reinforced concrete walls metal surfaces or grates electronic devices as well as the position of the sensor and or the receiver Placement of the sensor and the display unit e Place the sensor so that the back or front side is facing the receiver If possible avoid shields or disturbances in the line of transmission The remote sensor is weatherproof Avoid direct sunlight rain or snow Preferable are measuring p
2. JKBA 1 EASY SETUP Extremely user friendly weather station with barometer and trend indicator indoor thermo hygrometer wireless outdoor thermometer with frost protection radio controlled clock Table of contents ow n O T c O A oO 4 2 Air pressure indiCator cccccccceceeeeeeeeeeeeeeeeeeeeeceeeeeeeaeeeeeeeeesaaeeeeeseeeseeeeeenaeeseaes 46 A 53 Tend Ndc eg a E E EE A E Aedes eaaetene das 47 4 4 Temperature MOIStUIEC c ccccceeeeeeeeeeceeeeeeeeeeeceeeeesaaeeseeeeeesaaaeseeeeeesiaeeseaaeeee 48 4 5 TIME FUNGUO Mirin aeniea a a aiaei nai 49 s MOUBleES NOONG iorta are a e a etaan 50 Battery CMa Ng Eia ceana anneni n a a a aE a ANE a G Ea 51 OONAA o are ofthe ASVICC uincere ae e aaa aaan SENA eGA 51 SUP POM annas aiae a Ra E E a E E E E SS 51 F nctions andtechnical datassa as udaa e aaa eaa ans taeeeed Uaawuesde 52 Ducs gt 40 41 KSPO 1215 10 IROX OST21 amp TS01 MANUAL 4 Eng SIZE W160 x H170 mm BY Lai HZ 17 11 10 1 INTRODUCTION 2 OPERATING ELEMENTS Meteocentrale ch and unwetterzentrale de are weather forecasting portals operated by Meteomedia AG Meteomedia is one of the leading weather services in Europe and operates Severe Weather Centres in Switzerland Germany and France which makes them the specialists for modern early storm detection The core of the company is our extremely extensive weather station measurement network It is one of Europe s largest measurement net
3. meter to the display unit 3 Activate the batteries in the display unit First a full segment display will appear on the LCD for about 3 seconds 4 Then the sea level setting Om will blink on the display You now have 8 seconds to begin setting your local sea level using the buttons When you have reached the desired height wait 8 seconds then the device will start receiving data from the remote sensor and then the time from the time signal transmitter DCF77 Wait until all data time and temperature are indicated correctly on the device That is all you have to do From now on your device will function without you ever having to push another button In chapter 4 you will find details for optional settings and also information on certain procedures 4 EXTENDED OPERATION All operations on the device are carried out by pressing buttons It is very important that you read chapters 2 and 3 In these chapters you will find additional information about the functions 4 1 Weather forecasts This Irox device uses a high quality pressure sensor to measure barometric pressure and the respective changes This information is then using a by meteorologists specially developed algorithm used to calculate a weather forecast for the coming 12 24 hrs Eight different forecasts are possible 1 ss rT ie RE PAE ana tee ee ene ae ete tts ate ete me GY 1S Gey es 1G eS Him Ai i Sunny Slightly Cloudy Rain Heavy Snow Heavy Thunders
4. combine old batteries with new batteries Observe polarity when inserting batteries Please also remember that used batteries do not belong in domestic trash they should be disposed of at designated collection points Our environment will appreciate it Important note on batteries The JKBA 1 is delivered with batteries so that you can immediately put it into operation These batteries may not last as long as store bought batteries As soon as you have to replace the batteries in the remote sensor we recommend using alkaline batteries Especially when outdoor temperatures drop to 0 C 32 F or below these batteries will ensure a more reliable transmittal If possible even use lithium batteries e Never use rechargeable batteries The output of rechargeable batteries is often not sufficient for our devices 7 CARE OF THE DEVICE Do not expose the device to extreme temperatures or direct sunlight over longer periods Avoid blows and shocks of any kind to the device For cleaning use a dry soft cloth that you have moistened with water and a very mild cleaning agent Never use volatile substances such as benzene thinner cleansing agents in spray cans etc When the device is not being used store it in a dry area and out of the reach of small children In such cases it is important to remove the batteries If the device is activated under extreme coldness it may occur that the display becomes illegible As soon as it is returned to a wa
5. e000 eo000c0a000 0 e c000O0O0O0CaO O00 P eo00coO000 00000 L oe PRODUCT CODE JKBA 1 REF IR8 1070 30 X www irox com O L J PRESSURE UNIT SET ALTITUDE button e PRESSURE UNIT Press briefly Changes the pressure unit hPa or inHG e SET ALTITUDE Press and hold for 3 seconds to move to setting for local height above sea level Then set with button Important Exit setting by briefly pressing the button This leads to a reset and new start of the forecast calculation K WALL MOUNT e Prefabricated opening to using a screw or nail hang the device on the wall L BATTERY COMPARTMENT e Is designed for 4 tubular batteries size AAA Please observe polarity when inserting batteries M TABLE STAND e This stand can be clicked into the bottom of the device for positioning on a table 44 2 3 Remote sensor Temperature In an open and undisturbed field the measuring values can be transmitted over a distance of up to 30 meters 100 feet The remote sensor is weatherproof and can be used both outdoors and indoors L A BATTERY COMPARTMENT Designed for two AAA batteries if B WALL MOUNTING For mounting outdoors use the wall bracket d i y 45 3 SET UP Setting up the JKBA 1 is very easy Just follow the steps below 1 Activate the batteries in the remote sensor 2 Position the remote sensor in the same room in a radius of about
6. pressure development with graphic display choice of three graphic formats Measuring data Temperature Measurement range 5 C to 50 C 23 0 F to 122 0 F Resolution 0 1 C 0 2 F Relative Humidity Measurement range 30 to 80 Measurement cycle 10 seconds Barometer Measurement range 750 to 1100m hPa at 25 C 22 15 to 32 49inHG Measurement cycle 20 minutes Height adjustment range 200m to 3500 m Power Supply 4 x AAA batteries 1 5V Dimensions 139 x 107 x 15 mm plus table foot Remote sensor e Measuring and transmittal of outdoor temperature via 433mHz Measuring data Temperature Measurement range with alkaline batteries 10 C to 60 C 14 F to 140 F Resolution 0 1 C 0 2 F Rel Humidity Measurement range 30 to 80 Measurement cycle 10 seconds Radio frequency 433 MHz Transmission distance Max 30 meter 100 feet Transmitting interval approx 45 seconds Power Supply 2 x AAA 1 5V batteries Dimensions 38 x 105 x 18 mm plus mount Irox Development Technology ce 52
7. Press briefly to display min max recorded saved values of the thermometer and hygrometer RESET Press and hold for 3 seconds to delete saved values F CHART SYNC button e CHART Press repeatedly to change graphic display of pressure history from stacking bar charts increasing from left 24 Hr to right 0 Hr stacking bar chart silent indicator with blinking column 0 Hr line diagram silent with blinking segment 0 Hr Hr stands for hours and the chart displays the pressure history over the last 24 hours 0 Hr is the latest current state e SYNC Press and hold for 3 seconds to start synchronization with the sensor last logged into the device Caution After changing the sensor battery or to log in a new sensor you must press this button again for 3 seconds while the waves above are blinking G SET TIME button e SET TIME Press and hold for 3 seconds to move to time setting mode Please also read the chapter on Time Setting H button I button e When setting time and height these buttons can be used to adjust the value or increase or decrease To quickly change a value in the setting press and hold the or button 43 2 2 Stand battery compartment and button on back side y wF O o MEM RESET i K J PRESSURE UNIT SET ALTITUDES CHART eo0000oO000CeC O00 0 Woes C000000000000 f ooo0oo0o000000000 SET TIME
8. ing the forecast development ray ro OA X VAN VAN sms NS y ue cay gt gt gt 2 Graphic pressure history One bar equals hPa This displays the pressure history of the past 24 hours If you change the pressure units from hPA to inHG the graph will remain the same The only thing that vanishes is the scaling on the right side of the graph with the 4 to 4 hPa The graph can be displayed in 3 different ways Dynamic stacking bars increasing from 24 hrs to 0 hrs Ihbbioinus Ss 24 18 12 6 3 Static stacking bars only the 0 hrs bar blinks ANN woe St SLY THU TnI fil 24048 42 6 3 2 4 0 tr Static line diagram only the segment 0 hrs blinks 47 4 4 Temperature Moisture The display unit measures the temperature and relative humidity and receives additional measurements from the remote sensors included in the delivery The temperature can be displayed in C or F The comfort zone is calculated from the thermo hygro measurements of the display unit A frost warning is programmed on the remote sensor When the temperature measured by the remote sensor drops below 3 C the frost warning icon will appear on the display ee SEARCH FOR REMOTE SENSOR You can start the search for the remote sensor manually by pressing and holding the SYNC button for 3 seconds The wave icon will start to blink The wave icon indicates the receiving status of the remote sensor signa
9. l Icon Status N Searching for the remote sensor signal AN Sensor signal successfully received No signal received for over an hour With this search procedure the device searches the same sensor that was already previously logged in If you replace the batteries in the sensor the sensor gives itself a new code and will then no longer be recognized by the display unit You can resolve this problem by removing the batteries from the display unit and replacing them with new ones or if the batteries are still O K repeating the logging in procedure as described above by pressing and holding the SYNC button and while the wave icon is blinking press and hold the SYNC button again for 3 seconds The temperature indicator will start to blink indicating that a new sensor is being searched for and will be logged in INDICATION AND CONDITIONS OF THE COMFORT ZONE The COMFORT ZONE is indicated for the room where the main device is positioned The COMFORT ZONE is a function regarding temperature and rel humidity There are 5 conditions COMFORT WET DRY HOT and COLD C orY A wO Hot Hor h O 23 COMFORT pry wA coo com cor 1 o 40 65 99 rel humidity 48 4 5 Time function The time signal DCF 77 is transmitted by the atomic clock in Mainflingen near Frankfurt Main The long wave transmitter has a range of up to 1500km If the time icon P is displayed without waves
10. o with the setting During normal operation an automatic time reception will be activated daily at 0 00 3 00 6 00 and 12 00 As soon as the device has received a signal the time will be correctly adjusted and the P icon is active If reception is poor the icon will be displayed You may then set the clock manually at any time The next reception attempt will then be activated during the night ARN SETTING You can choose between two operating modes for the clock o 1 Radio controlled clock with regular time comparisons In between the active receptions the time runs on integrated quartz this is a factory setting which is reactivated after every battery replacement 2 Strictly as a quartz clock Move to set mode with the SET TIME button press and hold for 3 seconds On will appear in the time display This means the radio receiving is activated With the buttons you can make changes to the setting with the SET TIME amp button you move to the next setting The setting options vary depending on operating mode On or OFF Operating mode 1 Radio controlled clock on On Time indication format 24 hours or 12 hours resp AM PM Time zone setting standard 0 adjustable from 9 to 9 hours Time deviation as compared with the received radio time as the respectively valid time in Central Europe Germany France Switzerland Denmark etc If you set a time zone ZONE and the accordingly correc
11. oints in the shade for example under a weather protected roof with good air circulation The remote sensor can be stood or mounted vertically on a wall To do so please use the provided wall bracket this should be mounted on the wall with a screw not with a nail e Ideally the sensor should be placed 1 25m 4 feet over the ground respectively grass surface Stone asphalt or tar surfaces can become extremely warm and thus falsify the measurement e Heat sources such as a fireplace or heaters of any type must be avoided The display unit must be positioned within the transmitting radius of the sensor and away from the direct influence of heating or cooling apparatus A distance of at least 1 meter must also be maintained between sensor and display unit and other remote equipment Remote equipment is for example cordless telephones wireless headphones baby monitors mobile phones etc 50 6 BATTERY CHANGE lt a BATTERY CHANGE INDICATOR The batteries last for about 8 12 months Depending on the batteries used this time frame may be a bit shorter or longer A battery icon will appear to prevent an undesired and unexpected interruption of operation Battery icon in the temperature window This means that the batteries in the remote sensor need to be replaced Battery icon in the clock window This means that the batteries in the display unit are becoming too weak and must be replaced Important Use only new batteries and never
12. rm environment the device will function normally again Please keep the Instruction Manual and other documents delivered with the device stored carefully so that you can reference them at a later point if necessary Important All disposal fees in Switzerland vRG as well as in the EU WEEE for all Irox devices are covered 8 SUPPORT This device is a new development of Irox Development Technology All information was made and checked by means of a functioning device It may occur that adjustments and improvements of the device will take place that due to typographical procedures were not able to be listed in this manual Should you notice deviations which make it difficult for you to operate and use of the device you may at any time download the latest manual onto your PC free of charge at www irox com 51 9 FUNCTIONS AND TECHNICAL DATA Display unit Time e Absolutely accurate time by receiving the time signal DCF77 from Frankfurt Time format adjustable 12 or 24 hour format Time settings manually or as deviation from DCF77 time Weather Climate e Weather forecast for coming 12 to 24 hours via 8 icons Plus additional trend indicator e Room temperature and relative humidity with min max storage and 5 level Comfort Zone e Outdoor temperature via wireless remote sensor with frost warning e Barometric pressure display in hPA or inHG e Setting of sea level to calculate pressure at sea level 24 hour record of
13. ted time will appear on the time display This is ideal for locations where the DCF77 time signal is received but that have a different time such as Great Britain 1 HR or Finland 1HR Complete the setting with the SET TIME button Operating mode 2 Radio controlled clock off OFF Time indication format 24 hours or 12 hours resp AM PM Setting the hours Setting the minutes We recommend this operating mode for locations where the time signal can not be received Switching off the receiver spares the batteries 49 5 TROUBLESHOOTING If you notice a malfunction of your device always first check the battery please Always replace the batteries in the display unit and in the remote sensor Also please check the following before contacting the customer service of the store where you purchased the device issue Symptom Radio controlled clock Reposition the device Preferably near a window and leave it there overnight does not receive signal Perhaps an additional turning of the device by 90 would help Display unit Replace batteries in both devices Display unit Remote sensor is not Remote sensor being received Check the position of the sensor Read the details explained below s S Start sensor search with the SYNC amp button press and hold for 3 seconds If this is not successful repeat and while the waves above OUT are blinking press and hold SYNC button for 3 seconds again
14. torms cloudy rain snowfall Stormy COMMENT These calculated weather forecasts have a reliability of approx 70 The forecast is displayed not the current weather SUNNY means clear weather day and night 4 2 Air pressure indicator The indication of the air pressure depends on the setting of the sea level If the setting is 0 meters you will see the local measured pressure This value is based on the factory calibration of the pressure sensor If you have programmed the height above sea level of your location you will see the barometric pressure measured at your location calculated from the local pressure measured and the set height above sea level With this value you can meteorologically position your location with other available information e g the isobar map on TV Internet or in your daily newspaper With the height adjustment setting you can also adjust any slight deviations to a precision measuring instrument and so to say calibrate the pressure sensor As a rule 5m more in height pressure reading is increased by 1 hPa 46 4 3 Trend indicator You have a total of 4 different trend indicators available 2 of them simultaneously 1 The large Weather Icon on the upper right of the display shows the forecast for the next 12 24 hrs On the left side of that underneath the pressure indicator you will see a smaller icon with 3 arrows The small icon indicates the forecast 12 hours before thus giving you additional information regard
15. works Local and reliable forecasts are made using this measurement network Thanks to the collaboration with Meteomedia Irox market leader in the manufacturing of measuring devices has created a product line that convinces with high quality measurements easy handling and elegant design JKBA 1 is a high quality barometer with thermo hygrometer that provides you with absolutely new trend indications for weather development Setting up and using this device is very easy Please read chapters 2 and 3 The other chapters explain a few details that might be helpful to you for example if the radio controlled clock does not receive a signal and or you do not live within the central European time zone In the original package you will find following parts e The main unit the receiver e A table stand e A wireless external sensor transmitter e This Instruction Manual 42 2 1 LCD display and buttons front side All functions can be read from the liquid crystal display LCD in 3 windows D 7 l le p wu a a ery ey hPa ok E r C A a a ee s Iag ee C 1 a UEL G B 1 DRY i oq UM 7 o Tm i E P 24 148 12 6 3 2 4 0 fe H i c A CLOCK B TEMPERATURE MOISTURE C WEATHER AIR PRESSURE D C F button Changes the temperature unit Celsius or Fahrenheit E MEM RESET button e MEM
16. you have reception problems Please observe following points There are fewer disturbances in the atmosphere during the night which increases the likeliness of reception One reception per day is completely sufficient to ensure the preciseness of the clock by 1 second Make sure that the device is at least 2 meters 8 feet away from possible sources of disturbance such as TV computer monitor microwave etc In rooms with concrete or metal walls e g cellar rooms modern office buildings etc the receipt of the signal may be more difficult due to the shielding In such cases find a better location for the device near a window Sometimes it also helps to simply turn the device by 90 thereby improving the alignment of the receiving antenna Caution During the setting procedure as described below you will exit the setting mode if more than 1 minute passes between pressing the buttons The settings already made up to this point will then be deleted To prevent this from happening each setting must be completed RADIO CONTROLLED CLOCK RECEIVING LOGIC i As described in chapter 3 the time transmitted by the time signal transmitter DCF77 is automatically received when the batteries are activated The time signal reception takes about 3 10 minutes During receiving the P icon will blink if reception is good with waves if reception is poor without If you would like to switch the automatic time reception off and then on again you can do s