1. 3 1 Introduction 3 1 1 Principle NOTICE In case of unclear information please contact your local representative 3 1 2 Importance of safety instructions Each safety and protection instruction in this manual must be adhered to in order to avoid personnel injuries property damages or environmental pollution In a similar manner the legal bylaws the measures in prevention of accidents and for the pro tection of the environment as well as the recognized technical rules aiming at appropriate and safe working conditions which as applied in the country and at the place of use of the NurseCall N46 Wall Transmitter must be adhered to 3 1 3 Disregarding safety rules Disregarding the safety rules as well as existing legal and technical regulations may lead to accidents to property damages or to environmental pollution 3 2 Environmental conditions WARNING The NurseCall N46 Wall Transmitter must not be located near a water tap or any other source of water The electrical safety of the NurseCall N46 Wall Transmitter is only guaranteed if the electrical installation is in accordance with the national regulations and if this installation works prop erly The NurseCall N46 Wall Transmitter may not be used in buildings prone to fire and explosion hazards CAUTION The NurseCall N46 Wall Transmitter may not be used under exposure to the direct sunlight to heat to dust or to an excessive humidity only use the equipment in a cle
2. v1 1 2009 09 6 en Identification NurseCall N46 Wall Transmitter 1 2 Customer support addresses TeleAlarm SA Bosch Group Rue du Pont 23 CH 2300 La Chaux de Fonds Switzerland Phone 41 32 327 25 40 Bosch Security Systems France SAS Atlantic 361 361 avenue du G n ral de Gaulle F 92147 Clamart France Phone 33 0 825 12 8000 0 15 TTC min from a fixed line telephone Bosch Sicherheitssysteme GmbH Haus ServiceRuf Ingersheimer StraBe 16 D 70499 Stuttgart Germany Phone 49 0 711 3653 1000 Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UDO 5HN United Kingdom Phone 44 0 1895 878088 Bosch Security Systems BV Postbus 80002 NL 5600 JB Eindhoven Netherlands Phone 31 0 900 8212499 Bosch Security Systems nv sa Torkonjestraat 21F B 8510 Marke Belgium Phone 32 0 56 20 02 40 Bosch Security Systems AB Vestagatan 2 SE 416 64 G teborg Sweden Phone 46 0 31 722 5300 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Generalities en 7 2 Generalities 2 1 NurseCall System Alarms and Messages arriving from NurseCall Transmitters such as the NurseCall N46 Wall Transmitter are managed and stored by the NurseCall Main Unit NOTICE The document NurseCall General Overview explains the system concept 2 2 NurseCall N46 Wall Transmitter The NurseCall N46 Wall Transmitter is a
3. Alarm with staff presence page 25 6 2 Call for Assistance The Call for Assistance is triggered by pushing the Call for Assistance button blue The Call for Assistance is repeated approximately every 2 minutes until a call acknowledge ment takes place up to a maximum of 20 minutes This repeat function can be disabled by setting the solder bridge B4 A Call for Assistance is signaled by red double flashes on the signal lamp and by the alternate action release of the relay Call for Help 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Uselen 21 6 3 6 4 6 5 6 6 Call Acknowledgement Staff Presence The call acknowledgement is triggered by pushing the Acknowledgement button green The call acknowledgement stops immediately all repetitions of the calls Optionally a call acknowledgement triggers the Staff Presence signal by green flashes on the signal lamp and by activating the Staff Presence relay when the Caregiver pushes the Acknowledgement button when entering the room by switching off the lamp and releasing the Staff Presence relay when the Caregiver pushes the Acknowledgement button and leaves the room Reserve call The reserve call is triggered by pushing the external button connected to terminals 4 and 5 of the terminal block J6 The call can be triggered by closing NO or opening NC the contact The reserve call is repeated about every
4. Asitancewith stl A EZ Race Pos Assistance with staff Call for Help presence A oo green Call for Assistance unchanged Poo e Call Alarm with staff A GO Acknowledgement Call for Assistance Assistance with staff presence Ao Poo a a SW green Call for Assistance State before action Assistance without staff presence Acknowledgement presence Pos green Action State Relay contact Signal lamp Radio Message Assistance without A oo w none staff presence red Poo Assistance without Call for Help staff presence A oo UC red Call for Assistance unchanged p OO Call Alarm with staff A GO Acknowledgement Call for Assistance Assistance without staff presence Dei de WS red Call for Assistance State before action Staff presence without alarm Action State Relay contact Signal lamp Radio Message Staff presence A Oo e Gone without alarm p SD green Call for Help Alarm with staff A Ei 7 Call for Help presence Poo green oal Stand by A 6 O O Acknowledgement Acknowledgement Poo Call for Assistance Assistance with staff presence oO Poo S green Call for Assistance 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Operation en 27 7 3 2 Device behavior during coded key insertion and removal NOTICE
5. Assistance with staff presence Action State Relay contact Signal lamp Radio Message Assistance with staff presence Ao Poo green none Coded key insertion Assistance with staff presence unchanged aso Poo green Staff arrival with code Coded key removal Assistance without staff presence Dei Poo x red Staff departure with code State before action Assistance without staff presence Action State Relay contact Signal lamp Radio Message Assistance without staff presence Dei Poo w red none Coded key insertion Alarm with staff presence ASS Pos S green Staff arrival with code Coded key removal not possible State before action Staff presence without alarm Action State Relay contact Signal lamp Radio Message Staff presence without alarm AOO POO e green none Coded key insertion Staff presence without alarm AsO green Staff arrival with code unchanged P oo Coded key removal Stand by A S O SEET Code Poo 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Operation en 29 7 4 7 4 1 Operation with the staff presence processing deactivated Device behavior upon pressing a button State before action Stand by Ac
6. NOTICE The coded key insertion an removal functions are optional State before action Stand by Poo Action State Relay contact Signal lamp Radio Message Stand by ASO O none Poo Coded key Stand by A Oo O Staff arrival with insertion unchanged code S Poo Coded key Stand by A OO O Staff departure removal unchanged with code State before action Alarm without staff presence Action State Relay contact Signal lamp Radio Message Alarm without AGS e one staff presence red i de Alarm without Coded key staff presence AGS g Staff arrival with insertion p red code unchanged P Oo Coded key Alarni Without AGS Staff departure removal staff presence E red with code unchanged P oO State before action Assistance without staff presence Action State Relay contact Signal lamp Radio Message Assistance without A oo w none staff presence red de Coded key EE AO O Staff arrival with insertion Staff presence w red code unchanged Po Oo E Coded key fen Ot AO O Staff departure removal staff presence x red with code unchanged POO There is no state change when the coded key is inserted or removed 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Storage en 31 8 8 1 8 2 Storage One can distinguish between long term storage and short term storag
7. Use 20 6 1 Call for Help 20 6 2 Call for Assistance 20 6 3 Call Acknowledgement Staff Presence 21 6 4 Reserve call 21 6 5 Technical Alarm 21 6 6 Caregiver Arrival 21 6 7 Caregiver Departure 22 6 8 Daily Message and Battery Low Message 22 6 9 Error Message 22 7 Operation 23 7 1 Description of the six different states 23 7 2 Legend of illustrations 24 7 3 Operation with the staff presence processing activated 24 7 3 1 Device behavior when pressing a button 24 7 3 2 Device behavior during coded key insertion and removal 27 7 4 Operation with the staff presence processing deactivated 29 7 4 1 Device behavior upon pressing a button 29 7 4 2 Device behavior during coded key insertion and removal 30 8 Storage 31 8 1 Short term storage conditions 31 8 2 Long term storage conditions 31 9 Disposal 32 9 1 Disassembly 32 9 2 Local disposal locations 32 9 3 Returning to the manufacturer 32 9 4 Materials 32 9 4 1 Battery 32 10 Appendix 33 10 1 Electrical specifications 33 10 2 Dimensions and weight 33 10 3 Operating temperature 33 10 4 EC Declaration of conformity 34 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Identification en 5 1 Identification 1 1 Document Name No User Manual 970 030 Table 1 1 Document No Version Description vi 1 2009 09 First Edition Table 1 2 Version Management Bosch Security Systems User Manual 970 030
8. have not been dam aged during transportation 5 1 1 List of contents Reference Description RM 905 Fl NurseCall N46 Wall Transmitter RM 906 FI 2 screws 2 screw anchors 1 CR2450 3V Lithium battery 970 030 NurseCall N46 Wall Transmitter User Manual Table 5 1 Packing list Bosch Security Systems User Manual 970 030 v1 1 2009 09 14 en Installation NurseCall N46 Wall Transmitter 5 2 5 2 1 Installation Generalities gt Install the NurseCall N46 Wall Transmitter in a dry place away from any source of heat CAUTION Interferences Avoid immediate proximity to other electric devices such as a television 5 2 2 Wall installation The NurseCall N46 Wall Transmitter can be fixed with two to five screws on a wall Two holes at 60 mm interval are provided for direct mounting on connection boxes The three upper holes are used for positioning the device and cannot be reached from the installation compartment Two of the lower holes can be reached from outside and thus used for fixing the device 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Installation en 15 5 2 3 Connecting to the power supply The NurseCall N46 Wall Transmitter can be powered by a lithium battery or and an external 12 24 VDC power supply If the device is powered with an external power supply the battery i
9. tive impact on the environment and human health and promotes the recycling of materials For more information on available collection facilities contact your local waste collection ser vice or your local representative 9 1 Disassembly Only authorized personnel are allowed to disassemble a NurseCall N46 Wall Transmitter 9 2 Local disposal locations The nearest disposal locations are established in accordance with the currently applicable laws Ask the local authorities 9 3 Returning to the manufacturer If there is no practical disposal place the NurseCall N46 Wall Transmitter may be returned to your local representative 9 4 Materials The NurseCall N46 Wall Transmitter must be returned to an authorized point of recycling In order to protect people and environment the NurseCall N46 Wall Transmitter must be recy cled in an adequate manner Consequently all applicable laws and bylaws must be respected 9 4 1 Battery NOTICE The battery should never be placed in municipal waste Use a battery disposal facility if avail able Fig 9 1 Crossed out wastebasket symbol gt Please check local regulations for disposal of batteries or call your local representative for information 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Appendix en 33 10 10 1 10 2 10 3 Appendix Electrical specifications External power supply amp consumption 12 2
10. 0 Germany France Fax 41 32 327 25 41 Phone 49 0 711 3653 1000 Phone 33 0 825 12 8000 ch securitysystems bosch com Fax 49 0 711 811 5125 294 0 15 TTC Min from a fixed line telephone www telealarm com Haus Service Ruf de bosch com Fax 33 0 820 900 960 www bosch sicherheitsprodukte de 0 12 TTC Min from a fixed line telephone fr securitysystems bosch com www boschsecurity fr Bosch Security Systems Ltd Bosch Security Systems BV Bosch Security Systems nv sa Broadwater Park Postbus 80002 Torkonjestraat 21F North Orbital Road NL 5600 JB Eindhoven B 8510 Marke Denham Netherlands Belgium UB9 5HN Phone 31 40 25 77 200 Phone 32 0 56 20 02 40 United Kingdom Fax 31 40 25 77 202 Fax 32 0 56 20 26 75 Phone 44 0 1895 878088 nl securitysystems bosch com be securitysystems bosch com Fax 44 0 1895 878089 www boschsecurity nl www boschsecurity be uk securitysystems bosch com www boschsecurity co uk Bosch Security Systems AB Vestagatan 2 SE 416 64 Goteborg Sweden Phone 46 0 31 722 5300 Fax 46 0 31 722 5340 se securitysystems bosch com www boschsecurity se
11. 2 minutes until a call acknowledgement takes place up to a maximum of 20 minutes This repeat function can be disabled by setting the solder bridge B4 The reserve call is signaled in the same way as the Call for Help on the signal lamp and the relays Technical Alarm The Technical Alarm is triggered by activating the contact connected to terminals 3 and 4 of the terminal block J6 The alarm can be triggered by closing NO or opening NC the contact 3 Normally the Technical Alarm is repeated about every 2 minutes until a call acknowledgement takes place up to a maximum of 20 minutes but it is possible to deactivate the repetition of the technical alarms by opening the solder bridge B3 In this case the Technical Alarm is not repeated The Technical Alarm is signaled in the same way as the Call for Help on the signal lamp and the relays Caregiver Arrival The Caregiver Arrival message is triggered when the Caregiver inserts the coded key in the connector on the side of the housing J7 when entering the room This message will appear if the optional coded key function is available on the device Up to four categories of Caregivers may be identified by using different keys The Caregiver Arrival message is not repeated Bosch Security Systems User Manual 970 030 v1 1 2009 09 22 en Use NurseCall N46 Wall Transmitter 6 7 6 8 6 9 Insertion of the coded key is signaled by green flashes on the signa
12. 4 VDC Transmission lt 40 mA Idle mode lt 10 mA Battery power supply amp consumption 3V lithium battery CR2450 Transmission lt 30 mA Idle mode lt 10 pA Battery life Approx 2 years Table 10 1 Electrical specifications Dimensions and weight Casing dimensions mm Depth 26 Width 82 Height 132 Casing weight g Weight 200 including antenna and power supply adaptor Table 10 2 Dimensions and weight Operating temperature Operating temperature 0 55 C Table 10 3 Environmental conditions Bosch Security Systems User Manual 970 030 v1 1 2009 09 34 en Appendix NurseCall N46 Wall Transmitter 10 4 EC Declaration of conformity Security Systems BOSCH EC Declaration of Conformi The undersigned representing the following manufacturer Manufacturer Bosch Sicherheitssysteme GmbH Address Rue du Pont 23 2300 La Chaux de Fonds Switzerland hereby declare that the following product s Wall transmitter N46 CRS RM 905FI F 01U 066 636 Wall transmitter N46 with two relays CRS RM 906FI F 01U 066 639 Wall transmitter N46 with presence key CRS RM 905FIOPT1 F 01U 131 094 Wall transmitter N46 with two relays and presence key CRS RXX 90621 F 01U 066 640 is are in conformity with the regulations of the following marked EC directive s and bear s the CC mark accordingly reference numbe
13. BOSCH NurseCall N46 Wall Transmitter BOSCH en User Manual NurseCall N46 Wall Transmitter en 3 Table of Contents 1 Identification 5 1 1 Document 5 1 2 Customer support addresses 6 2 Generalities 7 2 1 NurseCall System 7 2 2 NurseCall N46 Wall Transmitter 7 3 Safety Instructions 8 3 1 Introduction 8 3 1 1 Principle 8 3 1 2 Importance of safety instructions 8 3 1 3 Disregarding safety rules 8 3 2 Environmental conditions 8 3 3 General safety instructions 9 3 3 1 Observation and information 10 3 4 Special safety instructions 10 4 Description 11 4 1 General description 11 4 1 1 Top view 11 4 2 Main functions 12 4 2 1 Red emergency call button 12 4 2 2 Blue assistance call button 12 4 2 3 Green acknowledgment button 12 4 2 4 Alarm signaling 12 4 3 Options 12 4 3 1 Identification of the nurse group 12 4 3 2 Relay contacts for external signals 12 5 Installation 13 5 1 Unpacking 13 5 1 1 List of contents 13 5 2 Installation 14 5 2 1 Generalities 14 5 2 2 Wall installation 14 5 2 3 Connecting to the power supply 15 5 2 4 Reset 15 5 2 5 Transmitter Identification 15 5 2 6 Operation Check 15 5 2 7 Replacing the battery 16 5 2 8 Configuration and Wiring 17 5 3 Inputs and Outputs 18 5 4 General inputs 18 5 5 Wired Outputs 18 Bosch Security Systems User Manual 970 030 v1 1 2009 09 A en NurseCall N46 Wall Transmitter 5 6 Wired Inputs 18 5 7 General configuration 19 6
14. The coded key insertion an removal functions are optional State before action Stand by Action State Relay contact Signal lamp Radio Message Stand by AsO de O none Coded key insertion Staff presence without alarm A BO Hope green Staff arrival with code Coded key removal Stand by AsO de O Staff departure with code State before action Alarm without staff presence Action State Relay contact Signal lamp Radio Message Alarm without staff presence AGO de SS red none Coded key insertion Alarm with staff presence ASS Pos green Staff arrival with code Coded key removal not possible State before action Alarm with staff presence Action State Relay contact Signal lamp Radio Message Alarm with staff presence ASS Pos green none Coded key insertion Alarm with staff presence ASS Pos WW green Staff arrival with code Coded key removal Stand by AO O de O Staff departure with code KKK Transmitter in Alarm without Staff Presence state If the call has not been acknowledged removing the key will turn the NurseCall N46 Wall Bosch Security Systems User Manual 970 030 v1 1 2009 09 28 en Operation NurseCall N46 Wall Transmitter State before action
15. all N46 Wall Transmitter can be set to one of six following states State Description Stand by No call is being processed Alarm without staff presence The patient has triggered a Call for Help but the Care Personnel has not yet responded Alarm with staff presence The Care Personnel has responded after a Call for Help Assistance without staff presence A Call for Assistance has been triggered without the presence of the Care Personnel Assistance with staff presence A Call for Assistance has been triggered in the presence of the Care Personnel Staff Presence without alarm The Care Personnel has responded without a previous call from the patient Each state is indicated by the signal lamp and by a special position of the output relays It is possible to configure the NurseCall N46 Wall Transmitter in order that the Call for Assistance can be triggered only if the Care Personnel is present the device does not manage the Staff Presence This mode makes sense only if the output relays are not provided or not used The transition to a specific condition depends on the device configuration of its actual condi tion and of the action completed as shown on the charts in the following chapters NOTICE When the NurseCall N46 Wall Transmitter is powered by an external power supply the signal lamps follow the state of the corresponding relay outputs Bosch Security Systems User Manua
16. an environment 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Safety Instructions en 9 gt Install the NurseCall N46 Wall Transmitter in a dry place away from any source of heat CAUTION Interferences Avoid immediate proximity to other electric devices such as a television 3 3 General safety instructions DANGER Electrocution During maintenance operations when the NurseCall N46 Wall Transmitter is powered and its casing is removed the NurseCall N46 Wall Transmitter may not be left unattended CAUTION The NurseCall N46 Wall Transmitter may only be connected to the electrical sources as described in Section 5 2 Installation page 14 CAUTION Maintenance and repairs may only be performed in accordance with the instructions and by authorized technical personnel only The sole possession of the User Manual does not allow the personnel to perform any kind of repair on the NurseCall N46 Wall Transmitter Take into account all the warnings and follow all the instructions displayed on the NurseCall N46 Wall Transmitter and those which are printed in the documentation Never try to use replacement pieces other than those authorized by the manufacturer of the NurseCall N46 Wall Transmitter CAUTION It is mandatory to use the products specified in the present User Manual to clean the Nurse Call N46 Wall Transmitter If you plan to use a
17. connected correctly The battery should be replaced exclusively by Authorized Personnel Dispose of used batteries according to instructions and regulations Battery type is 3V CR2450 DL2450 Procedure 1 Open the compartment cover 1 by sliding it downwards and then towards you 2 Carefully remove the used battery 2 3 Place the new battery The positive terminal must be facing you 4 Replace the compartment cover BOSCI BOSCH Fig 5 1 Replacing the battery 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Installation en 17 5 2 8 Configuration and Wiring NC NO NC_NO Connector J4 External Call for Help trigger pear push button NC B1 NO Solder bridges B1 and B2 are located on the bottom side of the PCB NC B2 NO Solder Bridges if soldered B8 Call for Assistance only by Staff Presence B7 Call for Assistance from terminals J6 4 5 B6 No Staff Presence processing B5 No Daily Message B4 No calling message repetition B3 Technical Alarm message repetition B1 REL 1 Call for Help polarity B2 REL 2 Staff Presence polarity Terminal J5 1 External 12 24 VDC power supply 2 GND 0 V 3 4 REL 1 Call for Help 5 6 REL 2 Staff Presence Connector J7 Presence Staff identification optional Terminal J6 4 5 Reserve Call or Call for Assistance 3 4 Technical Alarm 1 2 Call for Help Ji Externa
18. e If the NurseCall N46 Wall Transmitter must be temporarily stored it may not be necessary to wrap it completely However if you wish to store the NurseCall N46 Wall Transmitter for a longer time for instance in a storage room or any similar location it is recommended to use original packing material Short term storage conditions Unwrapped NurseCall N46 Wall Transmitter in a room gt Protection against direct sunlight and dust Long term storage conditions NOTICE The NurseCall N46 Wall Transmitter does not loose its programmed parameters when the power supply and the backup battery are disconnected NurseCall N46 Wall Transmitter in its original packing material in a storage room gt Backup battery removed gt Protection against direct sunlight and dust Bosch Security Systems User Manual 970 030 v1 1 2009 09 32 en Disposal NurseCall N46 Wall Transmitter 9 Disposal This chapter describes the appropriate disposal of the NurseCall N46 Wall Transmitter The NurseCall N46 Wall Transmitter is marked with a crossed out wastebasket symbol This means that at the end of its useful lifespan the product shall be disposed separately from ordinary household wastes in accordance to the EU Directive 2002 96 EC The product and its accessories shall be delivered to an appropriate collection facility that will permit recycling treatment and environmentally compatible disposal This will prevent nega
19. e contact closing causes a Reserve Call for Assis Call or a Call for Assistance tance NC The contact opening causes a Reserve Call or a Call for Assistance 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Installation en 19 5 7 General configuration The marks a factory setting Bridge State Function B3 Open Technical Alarms are not repeated Soldered Technical Alarms are repeated until alarm acknowledgement max 20 min B4 Open Calls except technical alarms are repeated until call acknowledge ment max 20 minutes Soldered Calls except technical alarms are not repeated B5 Open A daily message is sent every 24 hours Soldered Daily messages are suppressed B6 Open Staff Presence Processing is activated Soldered Staff Presence Processing is disabled B7 Open Activation of J6 4 5 terminal input causes a Reserve Call Soldered Activation of J6 4 5 terminal input causes a Call for Assistance B8 Open The Assistance Call does not depend on the presence of the Care Per sonnel Soldered The Assistance Call is possible only if the Care Personnel has signaled his her presence 0 NurseCall N46 Wall Transmitters that feature the output relays are delivered with the Staff Presence Processing activated B6 open Models that do not feature the output relays are delivered with the Staff Presence Process
20. ing disabled B6 soldered Bosch Security Systems User Manual 970 030 v1 1 2009 09 20 en Use NurseCall N46 Wall Transmitter Use Every time a NurseCall N46 Wall Transmitter is used by pressing a button or activating a wired input the device sends a radio signal and the lamps indicates its actual state Optionally two relays allow the transmission of status to a remote display such as the signal lamps placed on top of the door Each radio message is sent with a different code which allows the receiver NurseCall system to recognize the performed action NOTICE It is recommended to keep the button pressed until the lamp placed above the red button lights up 6 1 Call for Help The Call for Help can be triggered in three different ways by pushing the red Call for Help button by pushing the external switch connected to the J4 connector for example a pear push button by pushing the external button connected to terminals 1 amp 2 of the terminal block J6 The Call for Help is repeated approximately every 2 minutes until a call acknowledgement takes place up to a maximum of 20 minutes This repeat function can be disabled by setting the solder bridge B4 A Call for Help is signaled by red flashes on the signal lamp and optionally by the activation of the relay Call for Help NOTICE In some cases the action Call for Help generates a Call for Assistance action See Section State before action
21. l 970 030 v1 1 2009 09 24 en Operation NurseCall N46 Wall Transmitter 7 2 7 3 7 3 1 Legend of illustrations Legend Description ASS The contact of the Call for Help relay is closed AsO The contact of the Call for Help relay is open Be The contact of the Call for Help relay opens and closes alternately Pos The contact of the Staff Presence relay is closed de The contact of the Staff Presence relay is open O The signal lamps are off OO A signal lamp lights up in the indicated color or A signal lamp flashes in the indicated color 8 A signal lamp flashes quickly in the indicated color Table 7 1 Operation with the staff presence processing activated Device behavior when pressing a button State before action Stand by Action State Relay contact Signal lamp Radio Message Stand by A 6 O O none de Call for Help Alarm without staff A 2 EI Call for Help presence Oo red POO er E EE GE A a S green Acknowledgement P 5 Call for Assistance Assistance ioe A oO w Call for Assistance staff presence red de If the function Assistance only in case of Staff Presence is activated and the NurseCall N46 Wall Transmitter is not in Staff presence state the Call for Assistance causes a state Alarm without Staff Presence and a Call for Help radio message 970 030 v1 1 2009 09 User Ma
22. l Call for Help trigger input polarity A J2 Polarity of Technical Alarm input A J3 Polarity of terminal J6 4 5 input A Fig 5 2 Configuration and Wiring NOTICE Setting up one or more inputs to NC position results to higher power consumption This con figuration should be used with external power supply or will reduce the battery life Bosch Security Systems User Manual 970 030 v1 1 2009 09 18 en Installation NurseCall N46 Wall Transmitter 5 3 Inputs and Outputs 5 4 General inputs The marks a factory setting External riseger J4 Jack3 5mm_ JI NO Closing contact causes a Call for Help NC Contact opening causes a Call for Help Power supply J5 1 12 to 24V DC 2 GND OV 5 5 Wired Outputs Call for Help J5 3 4 B1 NO A Call for Help causes the closing of Relay the relay contact NC A Call for Help causes the opening of the relay contact Staff Presence J5 5 6 B2 NO Staff Presence signaling causes the Relay closing of the relay NC Staff Presence signaling causes the opening of the relay 5 6 Wired Inputs Call for Help J6 1 2 The contact closing causes a Call for Help Technical J6 3 4 J2 NO The contact closing causes a Technical Alarm Alarm NC The contact opening causes a Techni cal Alarm Reserve Call or J6 4 5 J3 NO Th
23. l lamp and by activating the Staff Presence relay Caregiver Departure The Caregiver Departure message is triggered when the Caregiver removes the coded key from the housing when leaving the room The Caregiver Departure message is not repeated Removing the coded key is signaled by switching off the green flashes on the signal lamp and by releasing the Staff Presence relay Daily Message and Battery Low Message The radio transmission can be checked by way of the daily message which is automatically sent about every 24 hours When the battery voltage is too low the daily message is replaced by a Battery Low message The transmission of the Daily Message can be disabled by setting the solder bridge B5 this does not influence the transmission of the Battery Low message Error Message The Error Message is sent every 2 minutes if the device has detected a general dysfunction or if one of the following triggering devices remains in its activated position for up to 4 minutes Call for Help Acknowledgement button Call for Assistance Reserve Call NOTICE The device connected to the Technical Alarm input is allowed to remain in the activated posi tion without transmission of the Error Message 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Operation en 23 7 7 1 Operation Description of the six different states During operation the NurseC
24. multifunction terminal radio transmitter designed for patients and nursing staff to make an emergency call summon assistance or cancel a call directly in the patient s room It is part of a NurseCall system and is easily expandable In the NurseCall system the NurseCall N46 Wall Transmitter allows the resident of a home or the patient of a clinic to easily alert the care personnel if needed The patient simply has to push the large red button The system is then able to control and to monitor the progress of the care personnel The alarm and event transmission is performed by radio There is no need for a wired connection between the NurseCall N46 Wall Transmitter and the NurseCall Main Unit this makes the system installation easy and allows great mobility Depending on the model two relay outputs are available and may be used to connect alarm and staff presence indicators such as for instance the signal lamps installed above the door Two LED signal lamps allow the progress to be monitored on the device In this document you will find all the information you need for the installation and the use of the NurseCall N46 Wall Transmitter Bosch Security Systems User Manual 970 030 v1 1 2009 09 8 en Safety Instructions NurseCall N46 Wall Transmitter 3 Safety Instructions WARNING The User Installer should read and understand this chapter before any intervention on the NurseCall N46 Wall Transmitter
25. nother product only do so after having obtained the authorization of the manufacturer gt bP Fb Be D WARNING Electro Static Discharge The NurseCall N46 Wall Transmitter contains highly sensitive electronic components It should be opened only in an ESD protected environment with respect to the following precautions gt Discharge yourself from electrostatic loads by touching a grounded conductive surface before opening the unit gt Avoid touching conductive parts inside the NurseCall N46 Wall Transmitter if not abso lutely necessary Bosch Security Systems User Manual 970 030 v1 1 2009 09 10 en Safety Instructions NurseCall N46 Wall Transmitter CAUTION Never let any liquid enter the system In case of liquid spill inside the NurseCall N46 Wall Transmitter act immediately as follows 1 Switch off the NurseCall N46 Wall Transmitter by taking out the battery or removing the power supply 2 Dry up the NurseCall N46 Wall Transmitter Clean the NurseCall N46 Wall Transmitter 4 Check its electrical functions Ga NOTICE For further information please contact your local representative 3 3 1 3 4 Observation and information In case of defective operation or any other technical incident for which no remedy is described in this manual please contact immediately your local representative Special safety instructions Appropriate safety instructions linked to specific risk
26. nual Bosch Security Systems NurseCall N46 Wall Transmitter Operation en 25 State before action Alarm without staff presence Action State Relay contact Signal lamp Radio Message Alarm without staff A GO e none presence Oo red POO Alarm without staff SO Call for Help presence A E red Call for Help unchanged p Oo Seen GE ge o green Acknowieogement Pos B Call for Assistance ASSISTANCE Without A oo w Call for Assistance staff presence red de If the function Assistance only in case of Staff Presence is activated and the NurseCall N46 Wall Transmitter is not in Staff presence state the Call for Assistance causes a state Alarm without Staff Presence and a Call for Help radio message State before action Alarm with staff presence Action State Relay contact Signal lamp Radio Message Alarm with staff A GO ane presence p rome green Call for Help a with staff oo EI Breen Call for Assistance Pos 5 Call Stand by A 6 O O Acknowledgement Acknowledgement Le POO Call for Assistance Assistance with staff A oo z Call for Assistance presence p foo green Bosch Security Systems User Manual 970 030 v1 1 2009 09 26 en Operation NurseCall N46 Wall Transmitter State before action Assistance with staff presence Acknowledgement presence Pos green Action State Relay contact Signal lamp Radio Message
27. onship between the identification code of the Transmitter and the place where it is installed floor room bed or single number This identification is programmed on the Nursecall Main Unit refer to the NurseCall Main Unit User Manual 5 2 6 Operation Check Once the transmitter has been installed and setup properly it is recommended to check all functionalities of the device The radio transmission can be checked by sending an acknowl edgement call by pressing the green button Bosch Security Systems User Manual 970 030 v1 1 2009 09 16 en Installation NurseCall N46 Wall Transmitter 5 2 7 Replacing the battery WARNING May explode if exposed to fire Use only original batteries intended for use with your NurseCall N46 Wall Transmitter Using other type of batteries could be dangerous Do not expose the battery to liquids Do not let the metal contacts on the battery touch another metal This could damage the battery Do not disassemble or modify the battery Do not expose the battery to extreme temperatures and never above 60 C 140 F For maximum battery capacity use the battery at room temperature Keep out of reach of children Use the battery for the intended purpose only Do not allow the battery to be put into the mouth Battery electrolytes may be toxic if swallowed CAUTION There is a risk of explosion if battery is replaced by a wrong type or if not
28. r title I 2004 108 EC EMC Directive EMC DI 2006 95 EC Low Voltage Directive LVD TT 89 106 EC Construction Products Directive CPD DI 1999 5 EC Radio equipment and Telecommunications Terminal Equipment R amp TTE according to annex V O 94 9 EC Electrical Apparatus for Potentially Explosive Atmospheres ATEX according to annex IV and VII The conformity of the product s with above ticked EC directives is provided by the compliance with the following standard s Standard s date EN60950 1 2006 11 EN61000 4 2 2001 12 EN50130 4 2003 09 EN300220 1 V2 1 1 2006 04 EN300220 1 V2 3 1 2009 04 EN300220 2 V2 1 2 EN61000 6 3 2007 09 EN301489 1 V1 3 1 2001 09 EN301489 3 V1 8 1 2008 04 N50371 2002 11 Place date ZC La Chaux de Fonds Vice President Business Unit R D Manager Business Unit 2009 06 03 Printed name Printed name ST CRS PG Riedemann ST CRS ENG1 2 Stauffer Document No N46 Version Al Template ST10 Q6507_Declaration of Conformity Version 1 03 Date 05 May 08 Page 1 Fig 10 1 EC declaration of conformity main page 970 030 v1 1 2009 09 User Manual Bosch Security Systems TeleAlarm SA Bosch Group Bosch Sicherheitssysteme GmbH Bosch Security Systems France SAS Rue du Pont 23 Haus ServiceRuf Atlantic 361 CH 2300 La Chaux de Fonds Ingersheimer StraBe 16 361 avenue du G n ral de Gaulle Switzerland D 70499 Stuttgart F 92147 Clamart Phone 41 32 327 25 4
29. rm LED indicators enhance the signaling of alarms The NurseCall N46 Wall Transmitter is easily expandable as a socket for pear push button is directly accessible Options Two main options can be implemented in the NurseCall N46 Wall Transmitter Identification of the nurse group and relay contacts for external signals Identification of the nurse group This can be made via a socket for coded presence plugs max 4 different allowing the use of programmable function keys to log on and log off Relay contacts for external signals Optionally relay contacts for room signal lights and connecting ports for wired room installation can be used 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Installation en 13 5 Installation 5 1 Unpacking The NurseCall N46 Wall Transmitter is carefully packed for transportation The components contained in the box are protected but should be handled with care Store the packaging material for further use storage or transport NOTICE In case of defective or missing equipment do not try to install the NurseCall N46 Wall Trans mitter Contact immediately your local representative 1 Take all components out of the box and place the NurseCall N46 Wall Transmitter on the working space 2 Check each component in the box in accordance with the list of contents below 3 Check that the NurseCall N46 Wall Transmitter and its accessories
30. s are described in the corresponding section of this manual 970 030 v1 1 2009 09 User Manual Bosch Security Systems NurseCall N46 Wall Transmitter Description en 11 4 Description 4 1 General description 4 1 1 Top view Fig 4 1 Top view 1 Red emergency call button 2 LED indicator for alarm 3 LED indicator for presence 4 Green acknowledgment button to acknowledge an alarm locally 5 Blue assistance call button 6 Socket for coded key insertion option 7 Installation compartment 8 Jack plug for pear push button Bosch Security Systems User Manual 970 030 v1 1 2009 09 12 en Description NurseCall N46 Wall Transmitter 4 2 4 2 1 4 2 2 4 2 3 4 2 4 4 3 4 3 1 4 3 2 Main functions The main function of the NurseCall N46 Wall Transmitter is to enable easier handling of emergencies and help directly from the patient s room Red emergency call button Its large red button with textured surface makes it easy to identify and to press launching an emergency call Blue assistance call button If upon arriving nursing staff requires additional help a call for assistance can be sent by pressing the round blue button Green acknowledgment button In all cases there is an automatic call repetition until cancel of the call Cancelling can be made directly on the room transmitter with the smaller green button Alarm signaling The presence and ala
31. s not necessary but it can be used as a backup power supply in case of power loss If the device is powered by the battery only the battery life is about 2 years However it is recommended to change the battery once a year If the device is powered by an external power supply and the battery is used as backup power supply it is recommended to check it at regular intervals for instance once a year and to change it if necessary CAUTION When powering the device the external 12 24 VDC power supply must be equipped with a setting off safety device that is easy to access The power supply must also be equipped with a safety fuse of lower value e g 100 or 125 mA 5 2 4 Reset All parameters are reset when powering up the device battery or external power supply This operation causes the synchronization of the daily message In order to perform a reset make sure to remove both the battery and the external power sup ply make a short circuit on the two pins marked Reset before powering the device up again See Section Fig 5 2 Configuration and Wiring page 17 NOTICE All connections as well as the configuration need to be carried out before powering the device insertion of the battery and or application of the external power supply 5 2 5 Transmitter Identification All NurseCall N46 Wall Transmitters are provided with their own radio identification code that is assigned in the factory During the installation it is necessary to set the relati
32. tion State Relay contact Signallamp Radio Message Stand by A 6 O O none Poo Call for Help E staff A E red Call for Help Poo Call AO O Acknowledgement Stand by PO Oo O Acknowledgement Call for Assistance Assistance without staff presence ACO de SW red Call for Assistance State before action Alarm without staff presence Acknowledgement PO Oo Action State Relay contact Signal lamp Radio Message Alarm without staff A GO g fae presence p oo red Alarm without staff rome Call for Help presence A EI ed Call for Help unchanged p OOo deg Cali Stand by A 6 O O Acknowledgement Call for Assistance Assistance without staff presence Dei Poo SW red Call for Assistance State before action Assistance without staff presence Acknowledgement PO Oo Action State Relay contact Signallamp Radio Message Assistance without A oo w none staff presence red de Assistance without Call for Help staff presence A oo w ed Call for Assistance unchanged p OOo rec Cal Stand by A Do O Acknowledgement Call for Assistance Assistance without staff presence ACO de x red Call for Assistance Bosch Security Systems User Manual 970 030 v1 1 2009 09 30 en Operation NurseCall N46 Wall Transmitter 7 4 2 Device behavior during coded key insertion and removal