Mobotix MX-Bell1-Button-F1

image

Contents

1. The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decentralized concept has made high resolution video MOBOTIX AG e D 67722 Langmeil Tel 49 6302 9816 103 Fax 49 6302 9816 190 sales mobotix com 31 578 _EN_V2_09 2013 Only for cards with activated mailbox feature see 724 System Manual Part 2 Adding User Cards O UY x 5 2 e E gt gt gt Flashing Power failure BellRFID Quick Install A The HiRes Video Company MOBOTIX Installation and Initial Operation of the BellRFID contd Enter your personal Super PIN on the keypad insert then press the OK key This key is now highlighted yellow Enter the Super PIN again then confirm by pressing the OK key If the two PINs are identical the LEDs in the center are flashing repeatedly in a sequence from top to bottom Next the top right key OK lights up green and the key at the center Letter lights up red aja ajo Remove the keypad insert and continue with the next step Note If you entered different Super PINs or more than 60 seconds passed between entering the PIN and confirming the module emits a warning sound and returns to the state after finishing the auto configuration In such a case you need to start again with step 4 5 Set the Bell Button Set to be Installed Depending on the bell button set you need to select one of the six possible button layouts To se
2. mobotix com in the Support gt Manuals section This document contains the wiring diagrams for the different connection variants e The BellRFID module is only to be used in the original frame of the MOBOTIX IP Video Door Station e Before installing make sure that the seal on the back of the BellRFID module has been properly attached e When inserting the module into the frame only press at the edge never at the center of the module e Make sure the device is not operated outside of its operating temperature range of 30 to 60 C 22 to 140 F e BellRFID and KeypadRFID can only be used on one MxBus with a later software version of the camera LED Patterns MOBOTIX BellRFID Order no MX Belll Core Left LED green o red Status LED e Right LED blue Blue function button Cindy Jones Status LED Thomas Jones Bell buttons e On Normal status e a On Device error Be oe ranily Dr Jones MD HiRes Video Innovations Made in Germany The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decentralized concept has made high resolution video systems cost efficient Recording New Mailbox Messages You can either use one of the system s predefined announcements or record custom announcements These announcements will be played back if the mailbox is activated and the ringing has not been answered A new custom announcement always replaces the last annou
3. key pressed the entire time Leave a Message BellRFID without Function Button e After pressing a bell button and announcement Keep the same bell button pressed while leaving the message e Without having pressed a bell button Not possible Open door with blue user card Hold the blue user card in front of the BellRFID module If the module denies access e g card has been deleted is not trained the red status LED above the ESC ALARM key lights up Upon Power Failure Red LED Is Flashing Press and hold the ESC ALARM key until the button illumination lights up You can now open the door with your user card during the next 10 seconds This feature is only available if the IP Video Door Station is equipped with a DoorMasier Play Back New Message If you are opening the door with a user card and the blue letter key is flashing 5 seconds there is at least one unflagged message in the corresponding mailbox You can now use one of the following functions Press the flashing key to play back the message Press again to repeat the message Flag the message i e the message cannot be played back ALARM at the door but only at a remote station e g MOBOTIX App MxEasy Play back next message The mailbox closes automatically 15 seconds after the last user action message or if you press the ESC ALARM button Notes e Please follow the notes on installing and operating the device in the T24 System Manual www
4. D 67722 Langmeil Tel 49 6302 9816 103 Fax 49 6302 9816 190 sales mobotix com C FC 2013 Declaration of Conformity www mobotix com gt Support gt MX Media Library gt Certificates Copyright MOBOTIX AG 2013 Made in Germany Technical information subject to change without notice
5. MxX Belll Core e YU x 5 2 e 3 gt gt gt BellRFID Available Bell as Button Sets The Jone EGOA Accessory Family The Janes CGE Cindy Jones Thomas Jones lt lt lt _ Dr Jones ME Nr lanae MND a a MOBOTIX BellRFID TESE Sae MX Belll Core m Te ere nes lin IP Video Door Station oot The Jones Family triple frame white The Jones Dr Jones MD Family RFID cards MOBOTIX nese for keyless entry included 1 admin card 5 user cards MOBOTIX MOBOTIX e BellRFID base module with 1 admin and 5 user RFID cards mmmar mum e Interchangeable bell button sets not included e Integrated RFID technology for keyless entry e Available colors white silver dark gray black amber e Usable with without function button for mailbox control e Up to 60 hrs backup power supply using DoorMaster accessory Quick Install M A The HiRes Video Company MOBOTIX Bell Button Module with RFID Technology for up to Five Parties e o e P65 eatherproo o ax sc1 22 to 140 F OK MENU Cindy Jones Thomas Jones k The Jones Family T30 to 60 ESC K 4 ALARM Dr Jones MD Module for MOBOTIX IP Video Door Station keyless entry and mailbox control can be combined with the different bell button sets MX Belll Button F1 F2 F3 F4 05 XL1 Free of charge printing service on www mobotix com gt Support Available Bell Button Sets for all color
6. Standard Connection IP Video Door Station with BellRFID InfoModule and DoorMaster Outdoor IP Video Door Station Indoor Door opener door sensor lock sensor YSTY 0 8 mm max length 50 m 55 yd DoorMaster Theft protection YSTY 0 8 mm max length 50 m 55 yd For additional information on the other connection variants and for installing see the 724 System Manual Part 1 on www mobotix com gt Support gt Manuals Bell RFI D Thomas Jones The J Family n InfoModule MOBOTIX 3 S 292383 M I O Terminal a FH HH zit The BellRFID module is installed in the exactly Sealing plug same manner as the KeypadRFID module Make sure that you follow the steps for the different as hardware scenarios of the IP Video Door Station with without DoorMaster as described in the T24 System Manual Part 1 for the KeypadRFID see below Note BellRFID and KeypadRFID can only be used on one MxBus with a later software version of the camera MxBus terminal Installation and Initial Operation of the BellRFID Before starting the installation and initial operation you should download part 1 and 2 of the 724 System Manual from the MOBOTIX website www mobotix com gt Support gt Manuals lf the installation of the IP Video Door Station with BellRFID is not followed by the initial operation right away MOBOTIX recommends to remove the keypad insert and to insert the button set before starting the inst
7. allation This way the soft rubber surface of the BellRFID base module is well protected until the module is brought into service bell buttons are then replaced by the keypad insert Note that the base module is weatherproof even without the bell buttons When replacing the button set or exchanging name plates you need to remove the module from the frame of the IP Video Door Station Use the blue MOBOTIX key for unlocking the module Make sure that you are activating the mechanical theft protection with the red turning knob in the door station frame only after you have finished the initial operation see the Section Mechanical Anti Theft Protection Lock in the T24 System Manual Part I In order to avoid having to remove the module and install it again you should insert the proper name plates before starting the initial operation Use our free of charge printing service on www mobotix com in the Support section Or use the supplied name plates made from sturdy specialty paper and write the names using a UV resistant marker 1 Insert the Name Plate s Remove the silicon insert from the button Recommendation Take a suitable tool without a sharp blade cautiously insert it into the slot gently press inward and lift the tool as shown Insert the labeled or printed name plate as shown the arrows at the side are pointing upwards later on ee aa GM snol 10 Dr m Place the silicon insert on top of the name plat
8. e push it into the frame at the top and at the bottom of the center then push its sides into the frame Make sure that the silicon insert fits flush into the frame of the bell button as shown to protect the name plate against humidity aK aL 2 Insert the Module into the Door Station You can use the BellRFID module as an alternative to the KeypadRFID but not yet side by side in the frame of an IP Video Door Station For installing and wiring the module follow the same steps as for the KeypadRFID Follow the description in the Section Installing the T24 KeypadRFID of the T24 System Manual Part 1 Likewise the other connection variants listed in the Section Overview Connection and Wiring Diagrams e g connecting an electrical door opener in a system without DoorMaster Finish the installation of the BellRFID module by following the steps listed in the Section Finishing the Installation of the T24 System Manual Part 1 Similar to the KeypadRFID the blue and the green status LEDs are flashing power supply OK ready for auto configuration HiRes Video Innovations Made in Germany systems cost efficient Installation Hint When installing the module insert it first on the right hand side Then use two fingers and press on the left hand edge until the module clicks into the frame Caution Only press at the edge never at the center of the module Make sure that the cabling is not pinched and dama
9. ged when installing the module 3 Execute Auto Configuration Place the supplied keypad insert into the base module push it into the frame at the top then push the bottom into the module Start the auto configuration of the IP Video Door Station by executing the steps listed in the Section Step 1 Performing the Auto Configuration of the 724 System Manual Part 2 connect all devices establish the power supply and press the bell button of the camera module immediately after the light and bell buttons are lighting up Once you have successfully completed the auto configuration the white camera illumination is on and the BellRFID shows the following status e The blue and the green status LEDs are flashing e The LED of the keypad behind the top right key OK is red Finish the auto configuration by executing the steps listed in the Section Functional Test Part I of the T24 System Manual Part 2 4 Enter Super PIN and Confirm The Super PIN is used to protect the system against misuse and also replaces the factory default password meinsm as the new admin password The password is also used when adding the door station to the MOBOTIX App or MxEasy for example user name is admin new password is the lt Super PIN gt Select a Super PIN that has a minimum of 8 and a maximum of 16 digits more and different digits make it more secure For additional information on the Super PIN see the 724 System Manual Part 2
10. horized access to the door The easiest method is to delete all cards user and admin and to train the remaining cards again later on In order to delete all cards hold the red admin card in front of the BellRFID module until the OK MENU key lights up red Then briefly remove the admin card and hold it in front of the module again the ESC ALARM key flashes red Now press and hold any bell button until the three LEDs at the top start flashing red Confirm the deletion by again pressing and holding the same bell button The LEDs light up in a sequence to confirm that all cards have been deleted The right status LED of the module briefly lights up green If you want to train the cards again execute the instructions of steps 7 and 8 Note It is also possible to delete only specific user cards or a lost admin card For additional information on how to do this see the 724 System Manual Part 2 Operation Buttons and Signaling Ring the Bell for One Party Briefly press the bell button of the desired party The LED of the button briefly lights up Leave a Message BellRFID with Function Button e After pressing a bell button and announcement Keep the blue letter key pressed while leaving the message e Without having pressed a bell button Briefly press the blue letter key and then the bell button of the party for which you want to leave the message As soon as the mailbox announcement stops you can start talking Keep the blue letter
11. lect a button layout press any one of the button contacts in the center The module shows the current button layout by flashing the LEDs in a specific manner see table below The configuration starts with pattern a pressing any button switches to the next pattern in ascending order After the last pattern the module returns to pattern a Pattern 1 MX Belll Button F1 LED 1 permanently blue function button LEDs 2 to 5 flashing white 4 bell buttons LED sequence A Press any one of these buttons Button Set Description LED 1 permanently blue 2 to 5 flashing white LED 1 permanently blue 2 3 4 5 sequence white LED 1 permanently blue 2 3 4 5 sequence white LED 1 permanently blue 2 3 4 5 sequence white LEDs 1 2 3 4 5 sequence white LEDs 1 to 5 flashing white simultaneously Once you have found the proper pattern keep any one of the buttons at the center pressed until the LEDs are flashing repeatedly in a sequence Next the top center and right buttons OK and Letter light up green and the button at the top left ESC lights up red Pattern a a ee 1h k The button contacts are now locked until the function and bell buttons have been inserted and the admin card has been trained 6 Insert the Function Bell Buttons In order to insert the function or bell buttons you need to remove the BellRFID module from the frame of the door station if you have not already done so Use the blue MOBOTIX key f
12. ncement that had been used You can set the current announcement using a remote station e g MOBOTIX App MxEasy Press your bell button and hold the blue user card in front of the module bell sound is played back green LED mailbox activated or red LED mailbox deactivated lights up Press the bell button again and keep it pressed as long as you record the announcement The red status LED is flashing while recording Additional BellRFID Features see T24 System Manual Activating Deactivating the Mailbox Checking the Mailbox without Opening the Door Keep the blue letter key pressed until it starts flashing then hold the blue user card in front of the module The first new message is played back Press the blue letter key to play back the messages again To delete the messages keep the ESC ALARM pressed until you hear a sound If there are no new messages any more the system will make a corresponding announcement Deleting User Admin Cards and Transponders e Card held in front of the module e All cards assigned to one bell button e Lost admin card e Specific user card or transponder using the assigned transponder number Changing the Super PIN Changing the Bell Button Set Technical Specifications See 2 galvanically separated inputs AC DC self p powered up to 50 V Dimensions ESC OK Cindy Jones iii s getr ane ffi Thomas Jones gd The Jones Family Dr Jones MD MOBOTIX AG e
13. or unlocking the module Insert the function and bell buttons in the proper order by inserting the elements from the bottom e g the blue function button first In order to avoid damaging the buttons press the elements into the module using two thumbs as shown The Jones The Jones Family amily e tie s ii Dr Jones MD The Jones Family Click the BellRFID module with the buttons into the IP Video Door Station as described in step 2 7 Train the Admin Card Now that you have entered the Super PIN and inserted the buttons you need to train the Admin card This card is used as the master key for authentication purposes and is required for training and deleting user cards for example For every day use however opening doors mailbox features you only need the blue user cards Note that you should always keep the admin card together with the Product Pass of the IP Video Door Station in a safe place Hold the admin card in front of the BellRFID module for 5 seconds until the sound stops The LEDs light up in a sequence to confirm that the card has been trained All three LEDs at the top are now green to show that the initial operation has been completed successfully The button contacts are now unlocked Continue with step 8 or finish the installation as described in the 724 System Manual Part 2 8 Add User Cards Any Time Later on This step is not part of the initial operation of the
14. system and can be performed at any time later on You can skip this step if you do not intend to use the features described here The blue user cards are used by the inhabitants to open the door without using a key and to listen to mailbox messages directly at the IP Video Door Station If the blue function button at the top has not been installed make sure that you pay attention to the corresponding key position for the LED patterns described in the following Hold the trained admin card in front of the BellRFID module The OK MENU key at the top right position lights up red If you want to use the keyless entry features and listen to mailbox messages at the door press the bell button of the party to which you want to assign the user card The selected button lights up white If you want to use this card only for opening the door i e for the nursing service make sure that you do not press any button now Hold the user card in front of the BellRFID module for 5 seconds until the module plays a sound The LEDs light up in a sequence to confirm that the card has been trained If you want to train additional cards repeat the steps listed in this section for each card Test the trained cards by holding them in front of the BellRFID module one by one The electrical door opener should open the door with each card In Case of Loss Theft Delete All Cards In case a user card is lost you need to delete this card in order to prevent unaut
15. variants Cindy Jones The Jones The Jones al Thomacdonas e Family Dr Jones MD Dr Jones MD MX Belll Button F3 1 large 2 small bell buttons with function button MX Belll Button F2 2 medium size bell buttons with function button MX Belll Button F1 Large bell button with function button You can use the blue function button at the door station to listen to new mailbox messages record new announcements and activate deactivate the mailbox Visitors can leave a message even without the function button The remaining mailbox features are easily controlled using the remote station of the door station i e MOBOTIX App Cindy Jones Caroline Jones Cindy Jones The Jones Family Thomas Jones Thomas Jones The Jones Family The Jones Family Dr Jones MD Dr Jones MD MX Belll Button XL1 XL bell button no function button MX Belll Button 05 5 small bell buttons no function button MX Belll Button F4 4 small bell buttons with function button Each BellRFID base module contains 6 RFID cards 1 admin 5 user cards Each button set contains pre cut name plates made of UV resistant paper If required you can replace the button sets later on in the same base module In order to configure the system using BellRFID the bell buttons are replaced by a keypad insert which is delivered with the base module Use our free of charge Printing Service on www mobotix com Support section