1. A ES Instruction Book for TENSIONED ADVANTAGE ELECTROL DA LITE IMPORTANT SAFETY INSTRUCTIONS 1 Read and understand all instructions before using 2 Position the cord so that it will not be tripped over pulled or contact hot surfaces 3 Ifan extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat When using your video equipment basic safety precautions should always be followed including the following 4 To reduce the risk of electric shock do not disassemble The use of an accessory attachment not recommended this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently by the manufacturer may cause a risk of fire electric shock or injury to persons TOOLS REQUIRED FOR INSTALLATION 1 2 Open Wrench 1 8 Hex Key or Socket Driver included PRE INSTALLATION Carefully unpack case from shipping carton m installation Make sure to recheck measurement of case for proper installation clearance 5 Remove any protective foam covering the outside of the case CASE INSTALLATION Set aside the Installation Kit Items inside will be used during b For shipping purposes foam is also inserted between the roller b
2. Green Data or Down White b b b b up UPD GND 5V STOP 3 POSITION DOWN SWITCH 749 28 5705 E C3 OOOO Splitter Front of Wall Back of Switch Wall Switch Dry Contacts 240V WIRING DIAGRAM WITH OPTIONAL BUILT IN VIDEO PROJECTOR INTERFACE CAUTION THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR FAILURE TO DO SO MAY DAMAGE THE CONTROLLER 1 Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projector s screen trigger output be sure to maintain the proper polarity The red wire from the VPI is the signal and the black wire from the VPI is the ground 2 Connect the wires from the VPI that are labeled Low Voltage Connection to the end of the extended screen trigger wires above IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Brown Hot 240VAC 50112 Power Source Ground Blue Common Green Yellow Ll Green Yellow Ground Brown Down Blue Common Black Up E ea White CITA Black Front of Wall Back of Switch Wall Switch 5 12 Volt Screen Tr
3. 622 3737 F 574 267 7804 or 877325 4832 E infoGda lite com www da lite com DL 0115 03 13 2012 Da Lite Screen Company LLC Printed in U S A 84215
4. and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the motor in limit set mode Turn the wall Switch over and use the up button on the front of the switch Press and hold the up button until the desired up position is reached If you travel too far up press the down button to move the screen downward If you press and let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch over press and hold the up tactile button until the LED on back of switch blinks green twice The up limit is now set CAUTION ADJUSTING THE UP LIMIT SWITCH BY MORE THAN 6 CAN CAUSE THE SCREEN SURFACE TO LOSE PROPER TENSIONING 5 To test the limit switch settings press and release the up or down buttons on the switch to operate the screen 6 Replace the switch and cover plate on the wall IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments even if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible SCREEN ADJUSTMENT FOR 220V 240V SCREENS 1 Remove the cover plate from the 3 button wall switch and remov
5. Output RJ 45 Jack Wire White Common Black Power Input 120VAC 60Hz RJ 22 Pin Outs Tab Is Facing Up 12 Blue Bus RP Data Yellow RO Data Green mH 5V Red m Ground Black RO Clock White Standard RJ 22 can be used in place of RJ 14 cable Data P AE Cable Green Ground Ground Must be Connected to Hot Building Ground Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Receptacle RJ 45 Pin Outs Tab Is Facing Up Manual 2 Brown 12V Blue Bus RP Data Yellow a RO Data Green 5V Red Ground Black m RO Clock Orange Manual 1 Purple TENSIONED ADVANTAGE ELECTROL INSTALLATION FOR 120V SCREENS 120V WIRING DIAGRAM WITH OPTIONAL BUILT IN VIDEO PROJECTOR INTERFACE CAUTION The projector must be turned off before connecting IMPORTANT NOTE The wall switch is REQUIRED to make any the trigger wires to the projector Failure to do so may damage limit switch adjustments EVEN if a third party control system is the controller used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger 3 conductor 20 24 gauge wire can be used in place of the output to the length required to reach the VPI When extending s
6. Y INSTALLATION Tools required for screen and roller assembly 2 Phillips Screwdriver 1 8 Hex Key 1 2 Open Wrench 1 4 Open Wrench or Socket Driver or Socket Driver Follow these steps if your screen and roller assembly was ordered separately from the case 1 Remove the access door First remove the 2 screws from the 6 Complete electrical hook up by snapping motor wire connector ends using a 2 phillips screwdriver Be sure to support the into case connector Figure 3 door during this step to avoid injury Then lift the door slightly 8 Test installation by running screen up and down a few times and pull away from the edge of the case Figure 1 s y 9 P Be prepared to stop screen should any objects obstruct the 2 Carefully unpack screen and roller assembly Use supplied 1 8 movement of the screen To prevent damage to the motor the hex key to remove shipping brackets attached to slat Remove standard duty cycle is 1 minute on and 3 minutes off fabric and roller assembly from shipping board using a 1 2 9 Re install the access door Procedure is the reverse of step 1 wrench Leave packing paper on roller listed above 3 To install screen and roller as
7. a low pitched hum Squeaking rubber end plug rubbing on motor Grinding Foreign object in screen rubbing on roller or fabric Gear noise Center roller in case Remove Replace motor assembly Coasting Defective brake Replace motor assembly Fabric hangs crooked Screen not installed properly Fabric has backed up inside case Fabric is damaged Check for level and plumb Adjust down limit switch slowly until roller is exposed and wrinkle comes out then readjust for proper drop Replace fabric 10 1 LIMITED FIVE YEAR WARRANTY ON DA LITE TENSIONED ADVANTAGE 16116019015 PRODUCTS ONLY Da Lite Screen Company LLC warrants these products to the original purchaser only to be free from defects in materials and workmanship for a period of five 5 years from the date of purchase by the original purchaser provided they are properly operated according to Da Lite s instructions and are not damaged due to improper handling or treatment after shipment from the factory This warranty does not apply to equipment showing evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dea
8. e the switch from the junction box 2 Locate small 3 position switch on back of wall switch See Figure 5 for 120V screens or Figure 8 for 220 240V screens 3 To adjust the down limit switch slide the 3 position switch to the down position Press and hold the down button to run the screen down to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON Ah CAUTION DO NOT ADJUST FOR MORE DROP THAN WHAT WAS ORDERED AT LEAST 1 1 2 WRAPS OF FABRIC MUST REMAIN ON THE ROLLER THIS SCREEN COMES STANDARD WITH 12 BLACK AT THE TOP SEE THE SPECIFICATION DATA SHEET FOR DETAILS 4 When the screen is in the desired down position slide the 3 position switch to the off center position The down limit Switch is now set 5 To adjust the up limit switch slide the 3 position switch to the up position Press and hold the up button to run the Screen up to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON Ah CAUTION ADJUSTING THE UP LIMIT SWITCH BY MORE THAN 6 CAN CAUSE THE SCREEN SURFACE TO LOSE PROPER TENSIONING 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit Switch is now set 7 To test limit switch setting make sure the 3 position switch is in the off center position Press and release the up or down button on the wall switch to operate the screen 8 Replace switch and cove
9. igger on Projector TROUBLESHOOTING Visit www da lite com products tutorials php to find installation and troubleshooting tutorials You will also find a link to Live Chat for interactive support Symptom You can contact us by email at info da lite com or by phone at 800 622 3737 or 574 267 8101 with any additional troubleshooting questions Cause Solution Screen will not operate and motor does not hum Incorrect line voltage Blown fuse Tripped circuit breaker No power to operating switch or junction Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line Replace fuse Reset circuit breaker Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white leads Screen will not operate Power at junction box and motor does not hum Thermal overload tripped Broken wire in the down or up position Defective motor limit switch or capacitor Capacitor burned out Let motor cool down for 15 minutes Try again Check for continuity Cut off old splice and reconnect Replace motor assembly NOTE Motor is a sealed assembly Replace motor assembly Screen does not stop at correct position Limit switch out of adjustment See Screen Adjustment section Noise NOTE Screen will operate with
10. ler to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the five 5 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Sales Partners at PO Box 137 Warsaw IN 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH DA LITE S WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership gn 9 GM an A Milestone AV Technologies Brand 3100 North Detroit Street Post Office Box 137 Warsaw Indiana 46581 0137 P 574 2678101 or 800
11. mbly was ordered separately from the case or if general adjustment is needed please follow the steps below and refer to the 120V Wiring Diagram 1 Locate the wall switch and remove the cover plate from the wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are black round buttons on silver plates See 120V Wiring Diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on the back of the switch turns solid red This will put the motor in limit set mode Turn the wall switch over and use the down button on the front of the switch Press and hold the down button until the desired down position is reached If you travel too far down press the up button to move the screen upward If you press and let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch over press and hold the down tactile button until the LED on back of switch blinks red twice The down limit is now set CAUTION DO NOT ADJUST FOR MORE DROP THAN WHAT WAS ORDERED AT LEAST 1 1 2 WRAPS OF FABRIC MUST REMAIN ON THE ROLLER THIS SCREEN COMES STANDARD WITH 12 BLACK AT THE TOP NOTE If the screen is in limit set mode and no buttons are pushed for 20 seconds the LED on the back of the wall Switch will turn off the motor will return to run mode
12. r plate on the wall NOTE If stop button is pressed the wall switch will reverse direction To correct this press the stop button again This will reset the switch You will have to re set both the up and the down limit settings IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible TENSIONED ADVANTAGE ELECTROL INSTALLATION FOR 120V SCREENS 120V WIRING DIAGRAM 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board Up Limit Tactile Button Down Limit Tactile Button Front of Back of Wall Switch Wall Switch RJ 22 Jack Connection to Wall Switch at o leo To view a video of this installation visit http youtu be t2Z09PVAhEg or use the OR code below g ORO RJ 14 Pin Outs Tab Is Facing Up Bus RP Data White RO Data Green mH 5V Red Ground Black Supplied RJ 14 cable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible LED RJ 22
13. rackets and endcaps Figure 1 Remove these foam blocks from the ends Remove the hanger brackets from the top of the case using a 1 2 wrench Do not discard the hardware it will be used during case installation to re attach the hanger brackets for mounting 1 Hang case and attach to support structure with bolts See Suggested Methods of Installation 2 Tighten bolts until trim flange is flush with ceiling NOTE For proper operation screen assembly must be level after installation 3 Remove 2 screws to open junction box Install electrical connections that apply to your unit Make sure to review the wiring diagram for proper hook up Replace junction box cover and secure with 2 screws NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C22 1 and the National Electric Code NEC NFPA 70 N If your case was ordered in advance of the screen and roller assembly your installation is now complete Continue to step 4 if your Tensioned Advantage Electrol was ordered as a complete unit Use supplied 1 8 hex key to remove silver shipping brackets attached to slat and screen case Test installation by running screen up and down a few times Be prepared to stop screen should any objects obstruct the movement of the screen To prevent damage to the motor the standard duty cycle is 1 minute on and 3 minutes off SCREEN AND ROLLER ASSEMBL
14. sembly loosen but do not remove four 1 4 20 nuts securing pin end bracket opposite end from the junction box to the case housing Slide the pin end bracket towards the end of the case Figure 2 4 nsert the motor end square shaft into the motor end bracket junction box end and secure with the clip Figure 3 5 Moving to the pin end of the case slide the pin end bracket until the hole fits securely over the pin Tighten the 1 4 20 nuts Clip on the pin end bracket securely Figure 2 1 4 20 Nuts r Motor Power Connector r Motor Access Door Screws Se ami o o O Q iy x O o o o y AR O Foam Blocks Motor Mount Bracket Figure 1 Figure 2 Figure 3 TENSIONED ADVANTAGE ELECTROL SUGGESTED METHODS OF INSTALLATION METHOD 1 6 7 16 Variable Position Mounting Bracket E ke Audience Side Motor End 6 1 16 ih a 3 8 Threaded Rod Not Included Electrical e e Attached To Junction Box Mounting Bracket 6 3 8 Self Trimming Flange Finished Ceiling oo 7 3 4 gt METHOD 2 3 8 Threaded Rod Not Supplied Hanger Bracket gt gt 3 7 16 SCREEN ADJUSTMENT FOR 120V SCREENS If your Tensioned Advantage Electrol was ordered as a complete unit the up and down limits were pre set by Da Lite If your screen and roller asse
15. upplied RJ 14 cable to connect the wall switch Connect the the low voltage connection from the projector s screen trigger BUS terminals on the wall switch to the corresponding BUS output polarity does not matter The red and black wires from terminals on the splitter board the VPI are interchangeable Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus LED RJ 22 Output RJ 22 Inputs Front of Back of Wall Switch Wall Switch Receptacle RJ 22 Jack Connection to Wall Switch RJ 45 Jack Data P A Cable VPI Trigger Module White Green Ground Common Ground Must be Connected to Black Hot Building Ground Power Input 120VAC 60Hz 5 12 Volt Screen Trigger on Projector TENSIONED ADVANTAGE ELECTROL INSTALLATION FOR 220 240V SCREENS 240V WIRING DIAGRAM IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Blue Common Power Input 240VAC 50112 Brown Hot Green Green Ground to Case NOTE Ground Must be Connected to Building Ground ILT RJ 9 Pin Outs Tab Is Facing Up IR or Up Black Ground Common Red 5