Tripp Lite 1.4kW Single-Phase Switched PDU, 120V Outlets (8 5-15R), 5-15P, 100-127V Input, 12ft Cord, 1U Rack-Mount
Contents
1. Para m s instrucciones acerca de c mo conectar la PDU en red consulte la Gu a de inicio r pido SNMPWEBCARD en el CD ROM que se incluye Cable de alimentaci n de energ a de CA Modelo PDUMH15NET2 El cable est permanentemente adherido al PDU y tiene una clavija NEMA 5 15P Cable de alimentaci n de energ a de CA Modelo PDUMH20NET2 El cable est permanentemente adherido al PDU y tiene una clavija NEMA L5 20P El adaptador de entrada de CA Modelo PDUMH2ONET2 El adaptador convierte las clavijas de entrada del NEMA L5 20P a clavijas de entrada NEMA 5 20P Recept culos de salida NEMA 5 15R PDUMH15NET2 Durante la operaci n normal los recept culos de salida distribuyen la energ a de CA al equipo conectado Cuando una salida est viva se ilumina el LED asociado 13 12 10 311 93 327B indb 13 12 13 2012 4 09 25 PM Recept culos de salida NEMA 5 15 20R PDUMH20NET2 Durante la operaci n normal los recept culos de salida distribuyen la energ a de CA al equipo conectado Cuando una salida est viva se ilumina el LED asociado Medidor Digital de Carga Amper metro La corriente el ctrica total utilizada por el equipo conectado se muestra en amperes en el medidor Repisa de Retenci n de cables Cuando est instalada en el PDU la repisa de retenci n de cables brinda puntos de sujeci n seguros para los cables de entrada y los cables del equipo conectado Soportes de Instalaci n Use estos sopo
2. FA Ey PDUMH15NET2 PDUMH20NET2 Switched Rack PDU e 120V 50 60Hz AC Input and Output AG 0091 AG 0092 Important Safety Instructions Installation Features Configuration and Operation Technical Support Warranty and Warranty Registration o Q M CF NM Espanol Francais 17 TRIPP LITE Since 1922 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite All rights reserved 12 10 311 93 327B indb 1 12 13 2012 4 09 13 PM Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of this product Failure to heed these instructions and warnings may affect the product warranty e The PDU provides convenient multiple outlets but it DOES NOT provide surge or line noise protection for connected equipment The PDU is designed for indoor use only in a controlled environment away from excess moisture temperature extremes conductive contaminants dust or direct sunlight e Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground he power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet s load rating The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for th
3. une prise de courant La PDU devrait tre fournie avec une protection contre les surintensit s PDUMH15NET2 avec un appareil de sectionnement valu pour la d rivation de 15 A PDUMH20NET2 avec un appareil de sectionnement valu pour la d rivation de 20 A 20 12 10 311 93 327B indb 20 12 13 2012 4 09 31 PM Installation suite PE Connexion du cordon d alimentation de l quipement Ins rer les cordons d alimentation dans les prises de sortie NEMA 5 15R EX PDUMH15NET2 ou les prises de sorties NEMA 5 15 20R EX PDUMH20NET2 Le voyant DEL E c t de chaque prise s allume quand la prise est pr te fournir du courant alternatif L indicateur de charge num rique 3 affichera la charge totale de l quipement en amperes Mise en r seau de l unit de distribution Pour des instructions sur le r seautage de la PDU se reporter au guide de d marrage rapide SNMPWEBCARD sur le CD ROM inclus Caract ristiques Cordon d alimentation CA Mod le PDUMH15NET2 ce cordon est attach en permanence la PDU et est muni d une prise NEMA 5 15P Cordon d alimentation CA Mod le PDUMH20NET2 ce co
4. Customer Support at 773 869 1234 for ordering information Note Do not connect a keyboard or mouse to this port Configuration Port Use this port to provide a direct terminal connection to a computer with a terminal emulation program A configuration cable part number 13 1243 is included with the PDU If you need to order a replacement cable contact Tripp Lite Customer Support at 773 869 1234 Ethernet Port Use this RJ 45 jack to connect the PDU to the network with a standard Ethernet patch cable The Link LED EX and Status LED Ed indicate several operating conditions as shown in the table below This port is not compatible with PoE Power Over Ethernet applications Network Operating Conditions EN Link LED Color Off No Network Connection Flashing Amber 100 Mbps Network Connection Flashing Green 10 Mbps Network Connection or 12 10 311 93 327B indb 6 12 13 2012 4 09 21 PM Configuration and Operation Remote Monitoring and Control The PDU provides remote monitoring EN outlet control EJ and more via Web browser telnet and SNMP based Network Management Systems For more information about configuration and operation of the PDU via the PowerAlert Web browser interface refer to the SNMPWEBCARD Users Guide included on the CD ROM bundled with the PDU Note for Network Management System Users Only Two MIB files Tripplite mib and RFC1628 mib must be loaded on each Network Management Station that
5. Input Power Cord Model PDUMH15NET2 The cord is permanently attached to the PDU and has a NEMA 5 15P plug AC Input Power Cord Model PDUMH20NET2 The cord is permanently attached to the PDU and has a NEMA L5 20P locking plug AC Input Adapter Model PDUMH20NET2 The adapter converts a NEMA L5 20P input plug to a NEMA 5 20P input plug NEMA 5 15R Output Receptacles PDUMH15NET2 During normal operation the output receptacles distribute AC power to connected equipment When an outlet is live its associated LED illuminates NEMA 5 15 20R Output Receptacles PDUMH20NET2 During normal operation the output receptacles distribute AC power to connected equipment When an outlet is live its associated LED illuminates Digital Load Meter Ammeter The total electrical current drawn by connected equipment is displayed on the meter in amperes Cord Retention Shelf When attached to the PDU the cord retention shelf provides secure attachment points for the input cord and connected equipment cords Use the included cable ties to secure the cords to the shelf 12 10 311 93 327B indb 5 12 13 2012 4 09 20 PM Features continued Mounting Brackets Use these brackets to mount the PDU PS 2 Port Use this port to connect a Tripp Lite ENVIROSENSE environmental sensor to provide remote temperature humidity monitoring and a dry contact interface to control and monitor alarm security and telecom devices Contact Tripp Lite
6. adecuado o seguro para el uso proyectado Ya que las aplicaciones individuales est n sujetas a gran variaci n el fabricante no declara ni garantiza la idoneidad o aptitud de estos dispositivos para ninguna aplicaci n espec fica Cumplimiento de las normas de los n meros de identificaci n Para fines de identificaci n y certificaci n del cumplimiento de las normas su producto Tripp Lite tiene asignado un n mero de serie nico Puede encontrar el n mero de serie en la etiqueta de la placa de identificaci n del producto junto con los s mbolos de aprobaci n e informaci n requeridos Al solicitar informaci n sobre el cumplimiento de las normas para este producto siempre mencione el n mero de serie El n mero de serie no debe ser confundido con el nombre de identificaci n ni con el n mero de modelo del producto Informaci n de sobre Cumplimiento de la WEEE para Clientes de Tripp Lite y Recicladores Uni n Europea Seg n la Directiva de Residuos de Aparatos El ctricos y Electr nicos Waste Electrical and Electronic Equipment WEEE y sus reglamentos cuando los clientes compran nuevos equipos el ctricos y electr nicos a Tripp Lite tienen derecho a e Enviar equipos antiguos para reciclaje seg n una base de uno por uno entre productos similares esto varia dependiendo del pa s Enviar el equipo nuevo de vuelta para reciclaje cuando este se convierta finalmente en desecho Tripp Lite tiene una pol tica de mejoramiento c
7. convient est ad quat et s r pour l usage pr vu Puisque les applications individuelles sont sujettes de grandes variations le fabricant ne fait aucune repr sentation ni n offre de garantie quand l applicabilit et la conformit de ces appareils pour une application particuli re Num ros d identification de conformit aux r glements des fins de certification et d identification de conformit aux r glements votre produit Tripp Lite a recu un num ro de s rie unique Ce num ro se retrouve sur la plaque signal tique du produit avec les inscriptions et informations d approbation requises Lors d une demande d information de conformit pour ce produit utilisez toujours le num ro de s rie Il ne doit pas tre confondu avec le nom de la marque ou le num ro de mod le du produit L information de conformit WEEE pour les clients de Tripp Lite et recycleurs Union europ enne Sous les directives et r glements de d chet d quipements lectrique et lectronique Waste Electrical and Electronic Equipment WEEE lorsque les clients ach tent le mat riel lectrique et lectronique neuf de Tripp Lite ils sont autoris s 553 Envoyer le vieux mat riel pour le recyclage sur une base de un contre un et en nature ceci varie selon le pays e Renvoyer le mat riel neuf pour recyclage quand ceci devient ventuellement un rebut La politique de Tripp Lite est celle d une am lioration continuelle Les sp cifications pe
8. re ou de la lumi re directe du soleil Ne pas connecter l unit PDU une prise sans mise la terre ou des cordons prolongateurs ou des adaptateurs qui liminent la mise la terre a demande d alimentation pour chaque pi ce d quipement connect e l unit PDU ne doit pas d passer la charge nominale d une prise individuelle La demande totale d alimentation pour l quipement connect e l unit PDU ne doit pas d passer la charge nominale maximale pour l unit PDU Ne jamais percer ou essayer d ouvrir une quelconque partie du bo tier de l unit PDU Aucune pi ce interne ne peut tre r par e par l utilisateur Ne pas essayer de modifier l unit PDU y compris les fiches d entr e et les c bles d alimentation Ne pas essayer d utiliser l unit PDU si une de ses pi ces est endommag e Ne pas essayer de monter l unit PDU sur une surface peu s re ou instable Ne jamais essayer de d installer un quipement lectrique pendant un orage est d conseill d utiliser cet quipement dans des applications m dicales o une panne de cet quipement pourrait normalement provoquer la panne de l quipement de survie ou alt rer notablement sa s curit ou son efficacit Ne pas utiliser cet quipement en pr sence d un m lange anesth tique inflammable avec de l air de l oxyg ne ou de l oxyde nitreux 18 12 10 311 93 327B indb 18 12 13 2012 4 09 29 PM Installation Montage de l u
9. y operaci n Control y monitoreo remoto El PDU ofrece monitoreo remoto EX 4mm c THPPUIE control de las tomas de corriente E y lt Se Die Atone legs fect fb m s v a navegador de Web telnet y VU Sistemas de Administraci n de Red basados en SNMP Para mayor informaci n acerca de configuraci n y operaci n del PDU v a la interfaz de navegador de Web de PowerAlert refi rase a la Gu a del Usuario incluida en el CD ROM que acompa a al PDU OVERVIEW Nota S lo para Usuarios de Sistema de Administraci n de Redes En cada Estaci n de are M TRIPP LITE Administracion de Red deben cargarse dos archivos aS MIB Tripplite mib y RFC1628 mib los cuales monitorearan al PDU mediante SNMP Los archivos estan disponibles en el CD ROM incluido en el empaque del producto MAN LOAD mon w or i cate LOADS Load Realm State Group Description 1 0 Of DAA AAA AAA 222222822222 228 15 12 10 311 93 327B indb 15 12 13 2012 4 09 26 PM Soporte t cnico Website www tripplite com support Correo Electronico techsupport tripplite com GARANT A LIMITADA El vendedor garantiza que este producto si se emplea de acuerdo con todas las instrucciones aplicables no tendr defectos en materiales ni mano de obra por un per odo de 2 a os a partir de la fecha de compra Si se verifica que el producto tiene defectos en los materiales o en la mano de obra dentro de dicho per odo el vendedor reparar o re
10. S OF MERCHANTABILITY OR FITNESS ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may have other rights which vary from jurisdiction to jurisdiction WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application WARRANTY REGISTRATION Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Notice Class A This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired op
11. ce Name Location syst mes de gestion de r seau SNMP Pour plus de renseignements au sujet de la configuration et du fonctionnement de la PDU via l interface du navigateur Web de PowerAlert se reporter au mode d emploi de la SNMPWEBCARD sur le CD ROM joint la PDU Remarque pour les utilisateurs du systeme de gestion de r seau uniquement Deux fichiers MIB Tripplite mib et RFC1628 mib doivent tre TRIPPLITE charg s sur chaque station de gestion de r seau oo ee qui surveillera la PDU via SNMP Les fichiers sont fournis sur le CD ROM inclus dans l emballage du produit MAIN LOAD Status POA aon yr cyale LOADS OVERVIEW Output Current 1 Output Current 2 T Auto Shed on Transition Disabled Load Banks Controllable 25 o Load Realm State Group Description 1 0 Off mor mor wor mor mor wor mor mor wor mor mor mor mor mor mor kel Save amp Cancel 23 12 10 311 93 327B indb 23 12 13 2012 4 09 33 PM Assistance technique Website www tripplite com support Courriel techsupport tripplite com GARANTIE LIMIT E Le vendeur garantit que ce produit s il est utilis selon toutes les directives applicables est exempt de d fauts d origine de mat riel et de main d uvre pour une p riode de 2 ans partir de la date initiale d achat Si le produit s av re d fectueux en mat riel ou en main d uvre durant cette p riode le vendeur r parera ou remplacera l
12. d 11 off after 00 11 Turn load 12 on after 00 12 Turn load 12 off after 00 12 Turn load 13 on after 00 13 Turn load 13 off after 00 13 Turn load 14 on after 00 14 Turn load 14 off after 00 14 Turn load 15 on after 00 15 Tum load 15 off after 00 15 Tur Inad 16 on after 00 18 Turn Inad 16 of after 00 18 i Save 2 Cancel 12 13 2012 4 09 21 PM Technical Support Website www tripplite com support E mail techsupport tripplite com Warranty and Warranty Registration LIMITED WARRANTY Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship for a period of 2 years from the date of initial purchase If the product should prove defective in material or workmanship within that period Seller will repair or replace the product in its sole discretion Service under this Warranty can only be obtained by your delivering or shipping the product with all shipping or delivery charges prepaid to Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Seller will pay return shipping charges Visit www tripplite com support before sending any equipment back for repair THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIE
13. e PDU Do not drill into or attempt to open any part of the PDU housing There are no user serviceable parts inside Do not attempt to modify the PDU including the input plugs and power cables Do not attempt to use the PDU if any part of it becomes damaged Do not attempt to mount the PDU to an insecure or unstable surface Never attempt to install electrical equipment during a thunderstorm Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide 12 10 311 93 327B indb 2 12 13 2012 4 09 13 PM Installation Mounting the PDU The PDU supports four primary mounting configurations 1U Rack OU Rack Vertical Wall and Under Counter Note Regardless of configuration the user must determine the fitness of hardware and procedures before mounting The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications Exact mounting configurations may vary Screws for attaching the mounting brackets and cord retention shelf to the PDU are included Use only the screws supplied by the manufacturer or their exact equivalent 726 32 3 16 flat head 1 1 1U Rack Mounting Use 4 scre
14. e produit sa discr tion Vous pouvez obtenir un service selon cette garantie seulement en livrant ou en exp diant le produit avec les frais d exp dition et de livraison pr pay s Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Le vendeur paierai les frais d exp dition de retour Visitez www tripplite com support avant d envoyer un quipement pour r parations CETTE GARANTIE NE S APPLIQUE PAS LUSURE NORMALE OU AUX DOMMAGES R SULTANT D ACCIDENTS DE MAUVAIS USAGE D ABUS OU DE N GLIGENCE LE VENDEUR N OFFRE AUCUNE GARANTIE EXPLICITE AUTRE QUE LA GARANTIE EXPRESS MENT SIGNIFI E LA PR SENTE EXCEPT SELON LES LIMITES DE LA LOI APPLICABLE TOUTES LES GARANTIES IMPLICITES Y COMPRIS TOUTES LES GARANTIES DE QUALIT MARCHANDE OU DE CONFORMIT UN BESOIN PARTICULIER SONT LIMIT ES EN DUR E LA P RIODE DE GARANTIE NONC E CI DESSUS ET CETTE GARANTIE EXCLUE EXPLICITEMENT TOURS LES DOMMAGES ACCESSOIRES OU CONS CUTIFS Certains tats ne permettent pas la limitation de la dur e d une garantie implicite et certains tats ne permettent pas la limitation ou l exclusion de dommages accessoires ou cons cutifs en cons quence les limitations et les exclusions ci dessus pourraient ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et vous pourriez avoir d autres droits selon les juridictions MISE EN GARDE L utilisateur devra prendre soin de d terminer avant de l utiliser si cet appareil
15. emplazar el producto a su sola discreci n S lo puede obtenerse servicio bajo esta garant a entregando o despachando el producto con todos los cargos de despacho o entrega pagados por adelantado a Tripp Lite 1111 W 35th Street Chicago IL 60609 USA El vendedor pagar los cargos de despacho del retorno Visite www tripplite com support antes de enviar alg n equipo para reparaci n ESTA GARANT A NO SE APLICA AL DESGASTE NORMAL O A DA OS RESULTANTES DE UN ACCIDENTE USO INADECUADO MALTRATO O NEGLIGENCIA EL VENDEDOR NO EXPRESA NINGUNA OTRA GARANT A DISTINTA DE LA ESTABLECIDA EN ESTE DOCUMENTO EN FORMA EXPL CITA EXCEPTO HASTA EL GRADO PROHIBIDO POR LAS LEYES APLICABLES TODAS LAS GARANT AS IMPL CITAS INCLUYENDO TODAS LAS GARANT AS DE COMERCIABILIDAD O IDONEIDAD EST N LIMITADAS EN DURACI N AL PER ODO DE GARANT A ESTABLECIDO ANTERIORMENTE ESTA GARANT A EXCLUYE EXPRESAMENTE TODOS LOS DA OS INCIDENTALES Y CONSECUENTES Algunos estados no permiten limitaciones sobre la duraci n de una garant a impl cita y algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que las limitaciones o exclusiones mencionadas pueden no aplicarse a usted Esta garant a le da derechos legales espec ficos pero usted puede tener otros derechos que var an de jurisdicci n a jurisdicci n ADVERTENCIA El usuario individual debe encargarse de determinar antes de usarlo si este dispositivo es apropiado
16. eration Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user must use shielded cables and connectors with this equipment Any changes or modifications to this equipment not expressly approved by Tripp Lite could void the user s authority to operate this equipment Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product WEEE Compliance Information for Tripp Lite Customers and Recyclers European Union Under
17. guirlas se afectar la garant a del producto e El PDU proporciona c modas salidas m ltiples pero NO proporciona protecci n contra sobretensi n o ruido en la l nea al equipo conectado e El PDU est dise ada s lo para empleo en interiores en un ambiente controlado lejos del exceso de humedad temperaturas extremas contaminantes conductores polvo o luz solar directa e No conecte el PDU a una salida sin conexi n a tierra ni a cables de extensi n o adaptadores que eliminen la conexi n a tierra El requisito de potencia de cada equipo conectado a1 PDU no debe exceder la capacidad de carga individual de la salida El requisito de potencia total para el equipo conectado el PDU no debe exceder la m xima capacidad de carga para el PDU No taladre ni trate de abrir ninguna parte de la cubierta del PDU No hay partes en su interior que requieran mantenimiento por parte del usuario e No intente modificar el PDU incluyendo los enchufes de entrada y los cables de alimentaci n No intente usar el PDU si alguno de sus componentes est da ado No intente montar el PDU en una superficie insegura o inestable Nunca intente instalar equipos el ctricos durante una tormenta el ctrica El uso de este equipo en aplicaciones de soporte de vida en donde la falla de este equipo pueda razonablemente hacer suponer que causar fallas en el equipo de soporte de vida o afecte significativamente su seguridad o efectividad no es
18. llos suministrados por el usuario A a trav s de los soportes de montaje DI y los hoyos de montaje en los rieles del bastidor o el estante para bastidor OO 09 0 0000 D OO OO INVADIDO EE Montaje en la pared Use 4 tornillos EX para instalar cada uno de los 2 soportes de instalaci n E al PDU como se muestra Monte el PDU a la pared insertando 2 o m s tornillos suministrados por el usuario A a trav s de los soportes de montaje D y en puntos de montajes Seguros 11 12 10 311 93 327B indb 11 12 13 2012 4 09 23 PM Instalaci n continuaci n 1 4 Montaje bajo el escritorio Use 4 tornillos EX para instalar cada uno de los 2 soportes de instalaci n EJ al PDU como se muestra Monte el PDU bajo el escritorio insertando 2 o m s tornillos suministrados por el usuario 4 a trav s de los soportes de montaje BJ y en puntos de montajes seguros ERJ Colocaci n de la Repisa de Control de Cables Opcional Use 2 tornillos EX para fijar la repisa de control de cables E al panel frontal del PDU Conexi n del PDU P Conecte los adaptadores de enchufe de entrada Opcional nicamente PDUMH20NET2 La PDU incluye un adaptador que convierte su enchufe de entrada L5 20P con fijaci n a un enchufe PDUMH20NET2 de entrada 5 20P est ndar La conexi n de este adaptador es opcional La PDU funcionar normalmente sin conectar este adaptador Nota la fuente de energ a CA no deber co
19. mpartir un circuito con una carga el ctrica pesada como la de una unidad de aire acondicionado o un refrigerador EX Conecte el cable de alimentaci n de energ a de entrada PDUMH15NET2 y PDUMH20NET2 Conecte la clavija de entrada EM a una fuente de energ a de CA compatible tal como un sistema UPS PDU o un servicio p blico Deber proporcionarse el PDU con protecci n de sobre corriente PDUMH15NET2 con un dispositivo de circuito ramificado de protecci n de m ximo 15A PDUMH20NET2 con un dispositivo circuito ramificado de protecci n de m ximo 20A 12 12 10 311 93 327B indb 12 12 13 2012 4 09 24 PM Instalaci n continuaci n EX Conexi n del Cable de Alimentaci n del Equipo Inserte los cables de energ a dentro de los recept culos de salida del NEMA 5 15R EX PDUMH15NET2 o los recept culos de salida del NEMA 5 15 20R EX PDUMH20NET2 El LED 1C pr ximo a cada toma de corriente se ilumina cuando la toma de corriente est lista para distribuir energ a CA viva El medidor digital de carga A mostrar la carga total del equipo conectado en amperes PDUMH20NET2 h Conectando Su PDU a la Red
20. nit de distribution d alimentation PDU L unit peut tre mont e selon quatre configurations principales b ti en 1U b ti en OU vertical au mur et sous comptoir Nota Sans tenir compte de la configuration l utilisateur doit d terminer la compatibilit de la quincaillerie et les proc dures avant d effectuer l installation L unit PDU et la quincaillerie incluse sont concues pour des types de b ti et bo tier courants et peuvent ne pas convenir toutes les applications Les vis pour fixer les supports de fixation et la tablette de retenue des cordons l unit sont incluses N utilisez que les vis fournies par le fabricant ou leur quivalent exact 6 32 de 3 16 po t te plate 4 1 Montage en b ti 1U Utiliser 4 vis EX pour fixer chacun des 2 supports de fixation E la PDU tel qu illustr Montez l unit de distribution dans le b ti en ins rant 4 vis fournies par vous 3 dans les supports de fixation BJ et dans les trous sur les rails du b ti 1 2 Montage en b ti OU vertical Utiliser 4 vis EX pour fixer chacun des 2 supports de fixation EJ la PDU tel qu illustr Montez l unit de distribution verticalement en ins rant 2 vis ou plus fournies par vous A dans les supports de fixation D et dans les trous sur les rails du b ti ou dans le coffret NINAS S OSSSSSoSS E Montage mural Utiliser 4 vis EY pour fixer chacun des 2 supports de fixation E la PDU tel qu ill
21. nnecting this adapter is optional The PDU will function normally without connecting this adapter Note The AC power source should not share a circuit with a heavy electrical load such as an air conditioner or refrigerator EE Connect Input Power Cord PDUMH15NET2 and PDUMH20NET2 Connect the input plug EM to a compatible source of AC power such as a UPS system PDU or utility outlet The PDU should be provided with over current protection PDUMH15NET2 with a maximum 15A branch rated protection device PDUMH20NET2 with a maximum 20A branch rated protection device 2 3 Equipment Power Cord Connection Insert power cords into the NEMA 5 15R output receptacles EM PDUMH15NET2 or NEMA 5 15 20R output receptacles EX PDUMH2ONET2 The LED EJ near each output receptacle illuminates when the receptacle is ready to distribute live AC power The digital load meter A will display the total connected equipment load in amps 12 10 311 93 327B indb 4 PDUMH2ONET2 12 13 2012 4 09 17 PM Installation continued Networking the PDU For Instructions on networking the PDU refer to the SNMPWEBCARD Quick Start Guide on the included CD ROM AC
22. ontinuo Las especificaciones est n sujetas a cambio sin previo aviso OD Excelencia en Manufactura Desde 1922 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 16 12 10 311 93 327B indb 16 12 13 2012 4 09 28 PM Manuel du propri taire PDUMH15NET2 PDUMH20NET2 Unite de distribution d alimentation PDU en bati e 120V 50 60Hz AC Input et Output AG 0091 AG 0092 Importantes consignes de s curit 18 Installation 19 Caract ristiques 21 Configuration et fonctionnement 23 Assistance technique 24 Garantie 24 English 1 Espanol 9 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite Tous droits r serv s 12 10 311 93 327B indb 17 12 13 2012 4 09 29 PM Importantes consignes de s curit CONSERVER CES DIRECTIVES Ce manuel contient des instructions et des mises en garde que vous devez respecter durant l installation l utilisation et l entreposage de ce produit Le non respect de ces instructions et mises en garde affecter la garantie du produit e l unit PDU offre de nombreuses prises pratiques mais elle N offre PAS de protection contre les surtensions transitoires et les parasites l quipement connect l unit PDU est concue pour un usage en environnement contr l l abri de l humidit excessive des temp ratures extr mes des contaminants conducteurs de la poussi
23. rdon est attach en permanence la PDU et est muni d une prise NEMA L5 20P Adaptateur d entr e CA Mod le PDUMH20NET2 l adaptateur convertit les fiches d entr e NEMA L5 20P en fiches d entr e NEMA 5 20P Prises de courant de sortie NEMA 5 15R PDUMH15NET2 durant le fonctionnement normal les prises de courant de sortie distribue du courant CA l quipement connect Lorsqu une prise est sous tension la DEL lui tant associ e s allume 21 12 10 311 93 327B indb 21 12 13 2012 4 09 32 PM Prises de courant de sortie NEMA 5 15 20R PDUMH20NET2 durant le fonctionnement normal les prises de courant de sortie distribue du courant CA l quipement connect Lorsqu une prise est sous tension la DEL lui tant associ e s allume Indicateur de charge num rique amp rem tre La totalit du courant lectrique utilis par l unit sera affich e en amp res Tablette de retenue des cordons Quand elle est install e l unit de distribution la tablette de retenue des cordons offre des points de fixation s rs pour les cordons d entr e et de l quipement connect Supports de fixation Utiliser ces supports pour monter la PDU Port PS 2 Utiliser ce port pour connecter un capteur environnemental ENVIROSENSE de Tripp Lite de facon fournir une surveillance distance de la temp rature et de l humidit et une interface contact sec pour commander et surveiller les dispositifs d alarme de
24. rtes para instalar el PDU Puerto PS 2 Use este puerto para conectar el sensor ambiental ENVIROSENSE de Tripp Lite para monitorear la temperatura y humedad en forma remota y una interfaz de contacto seco para controlar y monitorear los dispositivos de alarma seguridad y telecomunicaciones Comun quese al Soporte a Clientes de Tripp Lite al 773 869 1234 para solicitar informaci n Nota No conecte un teclado o rat n a este puerto Puerto de Configuraci n Use este puerto para proporcionar una conexi n directa de terminal a una computadora con un programa de emulaci n de terminal Se incluye con el PDU un cable de configuraci n n mero de parte 73 1243 Si necesita ordenar un cable de reemplazo comun quese al Soporte a Clientes de Tripp Lite al 773 869 1234 14 12 10 311 93 327B indb 14 12 13 2012 4 09 26 PM Caracter sticas continuaci n Puerto Ethernet Use este enchufe RJ 45 para conectar el PDU a la red con cable patch Ethernet est ndar El LED de Encadenamiento EX y el LED de Estatus FE indican varias condiciones de operaci n de acuerdo a lo mostrado en la tabla abajo Nota Este puerto no es compatible con la aplicaci n PoE Power over Ethernet Energ a sobre la Ethernet Condiciones de Operacion de la Red E Color del LED Estado Status Apagado Tarjeta no Inicializada Verde Constante Tarjeta Inicializada y en Operaci n Ambar Destellando Error Tarjeta no Inicializada Configuraci n
25. s curit et de t l communications Appeler l assistance la client le de Tripp Lite au 773 869 1234 pour des renseignements sur les commandes Note Ne pas connecter de clavier ni de souris ce port Port de configuration Utiliser ce port pour fournir un raccordement de terminaux direct un ordinateur avec un programme d mulation de terminaux Un c ble de configuration num ro de pi ce 73 1243 est inclus avec la PDU Si vous avez besoin de commander un c ble de rechange appeler le service la client le de Tripp Lite au 773 869 1234 22 12 10 311 93 327B indb 22 12 13 2012 4 09 33 PM Caract ristiques suite Port Ethernet Utiliser cette prise RJ 45 pour connecter la PDU au r seau l aide d un cordon de raccordement standard Ethernet La DEL de lien EM et la DEL de statut E indiquent plusieurs conditions de fonctionnement comme le montre e tableau ci dessous Note Incompatible avec les applications PoE Power Over Ethernet Conditions de fonctionnement du r seau E Couleur de la DEL de statut Status Carte non initialis e Vert stable Carte Initialis e et op rationnelle Ambre clignotant Erreur Carte non initialis e Configuration et fonctionnement Surveillance et commande distance La PDU offre la surveillance distance Power ler c EX a commande de prises B et plus E aem Actions Logs Preferences Help via navigateur Web telnet et les Model Name Type Devi
26. t recomendado No use este equipo en la presencia de una mezcla anest sica inflamable con aire oxigeno u xido nitroso 10 12 10 311 93 327B indb 10 12 13 2012 4 09 23 PM Instalacion Montaje del PDU El PDU soporta cuatro configuraciones primarias de montaje Bastidor TU Bastidor OU Vertical En la pared y debajo de la barandilla Nota Independientemente de la configuraci n el usuario debe determinar la idoneidad de los materiales y accesorios as como de los procedimientos antes del montaje El PDU y el material incluido est n dise ados para racks bastidores y cajas de rack bastidor comunes y pueden no ser apropiados para todas las aplicaciones Se incluyen los tornillos para fijar los soportes de montaje y la repisa para el retenci n de cables al PDU Use nicamente los tornillos suministrados por el fabricante o su equivalente exacto 6 32 3 16 de cabeza plana 1 1 Montaje en Bastidor 1U Use 4 tornillos EX para instalar cada uno de los 2 soportes de instalaci n E al PDU como se muestra Monte el PDU en el bastidor insertando cuatro tornillos suministrados por el usuario da trav s de los soportes de montaje PJ y los hoyos de montaje en los rieles del bastidor 000000000000000004 A go np 0000 EE Montaje en Bastidor OU Vertical Use 4 tornillos EX para instalar cada uno de los 2 soportes de instalaci n FA al PDU como se muestra Monte el PDU verticalmente insertando 2 o m s torni
27. the Waste Electrical and Electronic Equipment WEEE Directive and implementing regulations when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to e Send old equipment for recycling on a one for one like for like basis this varies depending on the country MS Send the new equipment back for recycling when this ultimately becomes waste Tripp Lite follows a policy of continuous improvement Specifications are subject to change without notice YE N Manufacturing Excellence Since 1922 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 8 12 10 311 93 327B indb 8 12 13 2012 4 09 21 PM Manual del propietario PDUMHI5NET2 PDUMH20NET2 PDU con tomas de corriente controlables para bastidor e 120V 50 60Hz AC Input y Output AG 0091 AG 0092 Instrucciones de seguridad importantes 10 Instalaci n 11 Caracter sticas 13 Configuraci n y operaci n 15 Soporte t cnico 16 Garant a 16 English 1 Francais 17 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Manufact Desde 1922 2012 Tripp Lite Todos los derechos reservados 12 10 311 93 327B indb 9 12 13 2012 4 09 23 PM Instrucciones de seguridad importantes GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones y advertencias que deben seguirse durante la instalaci n operaci n y almacenamiento de este producto De no se
28. ustr Montez l unit de distribution au mur en ins rant 2 vis ou plus fournies par vous 43 dans les supports de fixation D et dans des points de montage solides 19 12 10 311 93 327B indb 19 12 13 2012 4 09 30 PM Installation suite 1 4 Montage sous comptoir Utiliser 4 vis EN pour fixer chacun des 2 supports de fixation E la PDU tel qu illustr Montez l unit de distribution sous le comptoir en ins rant 2 vis ou plus fournies par vous A dans les supports de fixation D et dans des points de montage solides EE Tablette de retenue des cordons en option Utilisez 2 vis EX pour fixer la tablette de retenue des cordons EI au panneau avant de l unit Connexion de l unit de distribution d alimentation PDU Em Brancher les adaptateurs de fiches d entr e en option PDUMH20NET2 seulement La PDU comprend un adaptateur qui convertit sa fiche d entr e verrouillable L5 20P en fiche PDUMH2ONET2 d entr e 5 20P standard La connexion de cet adaptateur est facultative La PDU fonctionnera normalement sans proc der la connexion de cet adaptateur Remarque La source de courant alternatif ne doit pas partager de circuit avec une charge lectrique lourde comme un climatiseur ou un r frig rateur 2 2 Brancher le cordon d alimentation PDUMH15NET2 et PDUMH20NET2 Brancher la fiche d entr e EY une source d alimentation CA compatible telle qu un syst me ASC une PDU ou
29. uvent tre modifi es sans pr avis YE N Manufacturing Excellence Since 1922 TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 12 10 311 93 327B 24 12 10 311 93 327B indb 24 12 13 2012 4 09 35 PM
30. will monitor the PDU via SNMP The files are provided on the CD ROM included in the product package 12 10 311 93 327B indb 7 PowerAlert Power Management Software TRIPP LITE Status Device Actions Logs Preferences Help Alarm Status Model Name Type Device Name A Warning PDUMH30ATNET PDU Device 1 OVERVIEW 6 1215 V Normal Input Voltage 1 mew MANS Input Voltage 2 m 0 0 Input Frequency 1 m 59 9 urrent X Input Frequency 2 m 0 0 Auto Shed on Transition Disable Low Transfer Voltage 75 Load Banks Controllable 25 TRIPPLITE Status Device Actions Logs Preferences Controls Loads LoadGroups Events Device Discovery DEVICES Alarm Status Model Name Type Device Name 4 Waring PDUMV30NET PDU Device 1 Critical Envirosense Envirosense Probe MAIN LOAD Status On a om yr Cale LOADS Load Realm State Group Description Ramp Shed um load 1 on after00 01 Tumloadiofafer0001 A mor mor wor mor n Turn load 2 on after 00 02 Tum load 2 off after 00 02 Turn load 3 on after 00 03 Turn load 3 off after 00 03 Turn load 4 on after 00 04 Turn load 4 off after 00 04 Turn load 5 on after 00 05 Tumload5 off after 00 05 Turn load 6 on after 00 06 Turn load 6 off after 00 06 Turn load 7 on after 00 07 Turn load 7 off after 00 07 Turn load 8 on after 00 08 Turn load 8 off after 00 08 Turn load 9 on after 00 09 Turn load 9 off after 00 09 Turn load 10 on after 00 10 Turn load 10 off after 00 10 Turn load 11 on after 00 11 Turn loa
31. ws EX to attach each of the 2 mounting brackets E to the PDU as shown Mount the PDU in the rack by inserting 4 user supplied screws A through the mounting brackets El and into the mounting holes of the rack rails FE OU Rack Mounting Use 4 screws EX to attach each of the 2 mounting brackets EJ to the PDU as shown Mount the PDU vertically by inserting 2 or more user supplied screws A through the mounting brackets EI and into mounting points in the rack or rack enclosure 8999999S9999Ssssssssso 0 0 0 0 0 0 0 0 0 0 E wall Mounting Use 4 screws EN to attach each of the 2 mounting brackets EJ to the PDU as shown Mount the PDU to the wall by inserting 2 or more user supplied screws 3 through the mounting brackets El and into secure mounting points 1 4 Under Counter Mounting Use 4 screws EX to attach each of the 2 mounting brackets EJ to the PDU as shown Mount the PDU under the counter by inserting 2 or more user supplied screws A through the mounting brackets DJ and into secure mounting points 12 10 311 93 327B indb 3 12 13 2012 4 09 15 PM Installation continued ERJ Cord Retention Shelf Attachment Optional Use 2 screws EX to attach the cord retention shelf E to the front panel of the PDU Connecting the PDU EXT Connect Input Plug Adapters Optional PDUMH20NET2 Only The PDU includes an adapter that converts its L5 20P locking input plug to a standard 5 20P input plug Co
Download Pdf Manuals
Related Search
Related Contents
ClearWater Tech OAS20 111196 RX-822AS Taylor 390 Freezer User Manual 9/12(土)ステップアップセミナーチラシ【PDF:324KB】 AMX NXA-ENET8POE Freezer 「エアリーウィッグ(Airy Wig)」 テレビ通販番組 FirstMyCom取扱説明書 (Model:MP430F212) Mark-up of 5th version of AED10 Technical Note Copyright © All rights reserved.
Failed to retrieve file