Home

IBM System x 3630 M4

image

Contents

1. 9 Redbooks IBM System x3630 M4 IBM Redbooks Product Guide The IBM System x3630 M4 server offers a cost effective high capacity storage solution with exceptional energy smart design leadership virtualization and powerful systems management It supports up to two eight core Intel Xeon processors and high density memory designs with twelve DDR3 DIMM slots This 2U server consolidates storage and server into one system offers easy management and saves floor space and power consumption costing less money than traditional enterprise offerings Designed with redundancy flexible subsystems and a wider range of configuration options the x3630 M4 also offers an innovative Feature on Demand FoD design for an easier upgrade path Suggested use Collaboration email applications light databases virtualization cloud virtual desktops web serving and virtual storage The following figure shows the IBM System x3630 M4 Figure 1 The IBM System x3630 M4 Did you know The IBM System x3630 M4 server is designed to provide exceptional value and flexibility to meet general business or storage intensive requirements with up to 42 TB of storage space in a dense 2U form factor and 80 PLUS Platinum certified power supplies The flexible onboard Ethernet solution provides two standard integrated Gigabit Ethernet ports and two additional integrated Gigabit Ethernet ports with an optional software FoD upgrade without needing to buy additiona
2. e The lowest of maximum operating speeds for the selected memory configuration that depends the rated speed operating voltage and quantity of DIMMs per channel as shown under the Maximum operating speed section in Table 4 Table 4 Maximum memory speeds Part 1 RDIMMs DIMM type Specification Max memory at rated speed NS Maximum operating speed MHz 1 DIMM per channel 800 MHz Maximum quantity supported is shown for two processors installed When one processor is installed the maximum quantity supported is a half of what is shown Rated speed is not supported Memory DIMMs always operate at speeds lower than rated IBM System x3630 M4 12 Table 4 Maximum memory speeds Part 2 UDIMMs and LRDIMMs DIMM type UDIMM LRDIMM Specification Max quantity Largest DIMM Max memory capacity Max memory at rated speed Maximum operating speed MHz 1 DIMM per channel 1333 MHz 1333 MHz 1066 MHz 1333 MHz 2 DIMMs per channel 1066 MHz 1066 MHz 800 MHz 1066 MHz Maximum quantity supported is shown for two processors installed When one processor is installed the maximum quantity supported is a half of what is shown Rated speed is not supported Memory DIMMs always operate at speeds lower than rated The following memory protection technologies are supported ECC Chipkill for x4 based memory DIMMs Memory mirroring Memory rank sparing Chipkill works only in independent channel mode the default
3. Openbay 2 4 5 5 Multi 1 550 W 10MB 1066MHz 80W 1333 MHz HS 8 burner HS 2 7158 E3G 1x E5 2430 6C 2 2GHz 1x8 GB M5110 12x 3 5 2x 500 GB 2x GbE 4 5 5 None 1x 750W 15MB 1333MHz 95W 1333 MHz 512 MB f HS 14 7 2K SATA HS 2 7158 E4G 1 E5 2420 6C 1 9GHz 1x8 GB M5110 8x3 5 1x 500GB 2x GbE 4 5 5 Mutti 1x 550W 15MB 1333MHz 95W 1333 MHz HS 8 7 2 SATA burner HS 2 United States Latin America Canada 7158 EAU 1x E5 2407 4C 2 2GHz 1x8 GB M5110 8 3 5 Openbay 2xGbE 4 5 5 Multi 1x 550W 10MB 1066MHz 80W 1333 MHz HS 8 burner HS 2 7158 EBU 1x E5 2420 6C 1 9GHz 1x8 GB M5110 8 3 5 Openbay 2xGbE 4 5 5 Multi 1x 550W 15MB 1333MHz 95W 1333 MHz 512 MB f HS 8 burner HS 2 7158 ECU 1 E5 2440 6 2 4GHz 1x 8 GB M5110 8 3 5 Openbay 2 4 5 5 Multi 1 550 W 15 1333MHz 95W 1333 MHz 1 GB f HS 8 burner HS 2 MTM Machine Type Model T Processor detail Processor quantity and model number of cores core speed L3 cache memory speed TDP For models E1G and EAU the standard DIMM is rated at 1333 MHz but operates at up to 1066 MHz to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options This model is available only in Russia Commonwealth of Independent States R CIS This model is not available in Russia Commonwealth of Independent States R CIS f The ServeRAID M5110 RAID controller in
4. G200eR2 with 16 MB memory integrated into the IMM2 Maximum resolution is 1600x1200 at 75 Hz with 16 M colors Operating systems Microsoft Windows Server 2012 2008 R2 and 2008 x64 Red Hat Enterprise Linux 5 and 6 supported SUSE Linux Enterprise Server 10 and 11 VMware ESX 4 1 and VMware ESXi 4 1 embedded hypervisor and VMware vSphere 5 Limited warranty Three year customer replaceable unit and on site limited warranty with 9x5 NBD Service and Optional service upgrades country specific are available through IBM ServicePac support offerings 4 hour or 2 hour response time 8 hours fix time one year or two year warranty extension remote technical support for IBM hardware and selected IBM and third party Microsoft Linux VMware software Dimensions Height 86 mm 3 4 in width 447 mm 17 6 in depth 749 mm 29 5 in Weight Minimum configuration 16 4 kg 36 2 Ib maximum 28 2 kg 62 2 Ib The x3630 M4 servers are shipped with the following items Registration flyer Statement of Limited Warranty Important Notices Rack Installation Instructions Documentation CD containing nstallation and User s Guide IBM Systems Director 6 3 Base for x88 DVD ROM Rail kit static rails non sliding no cable management arm included One 2 8m 10A 100 250V C13 to IEC 320 C14 rack power cable IBM System x3630 M4 8 Standard models The following table lists the standard models Table 2 Standard models MTM Intel Xeo
5. G2HS HDD 3 5 NL SAS Hot Swap HDDs 00W1533 IBM 2 7 2K 6Gbps NL SAS 3 5 G2HS SED 90Y8577 IBM 3TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 3 5 NL SATA Hot Swap HDDs 81Y9786 A22Y IBM 500GB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 81Y9790 IBM 1TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 49Y6002 IBM 4TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 3 5 NL SATA Simple Swap HDDs 81Y9806 1TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 81Y9810 IBM 2TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 81Y9814 IBM 3TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 49Y6012 7 2K 6Gbps NL SATA 3 5 G2SS HDD 00W1296 IBM 256GB SATA 3 5 MLC HS Enterprise Value SSD 00W1301 IBM 512GB SATA 3 5 MLC HS Enterprise Value SSD IBM System x3630 M4 20 Internal backup units The server supports the internal backup options listed in the following table The USB Tape Drive Cage assembling kit part number 90Y6370 is required to support these tapes internally The internal tape drive is connected to the dedicated internal USB port on a system board Table 10 Internal tape drives Part Feature Description Maximum number code supported 90Y6370 A1ZM USB Tape Drive Cage assembling kit 46C5399 5711 IBM DDS Generation 5 USB Tape Drive 39M5636 5395 IBM DDS Generation 6 USB Tape Drive For more information see the list of IBM Redbooks Product Guides in the Backup units category http www redbooks ibm com portals systemx Open amp page pg amp cat tape Optical drives The server supports the optical
6. IBM Redbooks Product Guides in the Top of rack switches category http www redbooks ibm com portals systemx Open amp page pg amp cat tor IBM System x3630 M4 40 Uninterruptible power supply units The server supports attachment to the uninterruptible power supply UPS units listed in the following table Table 32 Uninterruptible power supply units For more information see the list of IBM Redbooks Product Guides in the Power infrastructure category http www redbooks ibm com portals systemx Open amp page pg amp cat power IBM System x3630 M4 41 Power distribution units The server supports attachments to the power distribution units PDUs listed in the following table Table 33 Power distribution units part 1 Switched and Monitored PDUs IBM System x3630 M4 42 Table 33 Power distribution units part 2 Universal PDUs For more information see the list of IBM Redbooks Product Guides in the Power infrastructure category http www redbooks ibm com portals systemx Open amp page pg amp cat power IBM System x3630 M4 43 Rack cabinets The server supports the rack cabinets listed in the following table Table 34 Rack cabinets For more information see the list of IBM Redbooks Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack IBM System x3630 M4 44 Rack options The server supports the rack console switches and monit
7. Interrupt throttling control Legacy and Message Signal Interrupt MSI Message Signal Interrupt Extension MSI X Receive Side Scaling RSS for Windows Scalable I O for Linux environments IPv4 IPv6 TCP UDP Support for packets up to 9 5 KB jumbo frames IBM System x3630 M4 24 The following table lists additional supported network adapters Table 14 Network adapters ie SE fem number code Description supported 0008850 asPN FDR O e mar Broodeom 1 Duer Pon Adepte tor BM System x fa uec me x520 DAZ Dual Pon 10 SFe Srem a Hevrsm me Duel Por Aone or iM Syer O O e 0000800 papu iore siem Integrated NIC upgrades ovens wes Epress E acres ams nove 110 Eps ss Eps Ovaa Pon Emenee 6 ewe ps mower 4200 ser nl Dust eon 420 sme el emeret Pon Sener Aso saorar em vs pesi nentreme rausa Pon Gee fe bove nave Bosse nope Dil rasper orem syer e T One FCoE iSCSI license per one Emulex Dual Port VFA III or Integrated VFA III One FCoE iSCSI license per one QLogic 8200 Dual Port VFA Virtual Fabric Adapters and Converged Network Adapters require SFP optical transceivers o
8. MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confirm the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products This information contains examples of data and reports used in daily business operations To illustrate the
9. drive options listed in the following table The installation of optical drive may require x3630 M4 ODD Cage assembly part number 00D9051 Standard models of x3630 M4 with four or eight HDDs ship with the ODD Cage assembly installed Server models with twelve 3 5 inch HDDs do not support an internal optical drive Table 11 Optical drives Part number Feature Description Maximum Standard models code supported where used 46M0901 4161 IBM UltraSlim Enhanced SATA DVD ROM 46M0902 4163 UltraSlim Enhanced SATA Multi Burner C4x IBM UltraSlim Enhanced SATA DVD ROM part number 46M0901 supports the following media and speeds for reading CD ROM 24X CD R 24X CD RW 24X DVD ROM 4 7 GB 8X DVD ROM dual layer 8 5 GB 8X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 8X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 8X DVD RW 4 7 GB 8X DVD RW 4 7 GB 8X DVD RAM 4 7 GB 5X IBM System x3630 M4 21 IBM UltraSlim Enhanced SATA Multi Burner 46M0902 supports the same media and speeds for reading as DVD ROM 46M0901 This drive also supports the following media and speeds for writing CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed CD RW 24X Ultra Speed Plus CD RW 24X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 6X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 6X DVD RW 4 7 GB 6X DVD RW 4 7 GB 8X DVD RAM 4 7 GB 5X I O expansion options The server supports up to five PCle slots with different riser cards ins
10. internal connectors SFF 8087 Supports connections to SAS SATA drives and SAS Expanders Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade Supports 512 MB battery backed cache or 512 MB or 1 GB flash backed cache Support for SSD performance optimization with the optional M5100 Series Performance Accelerator and SSD Caching Enabler Up to 6 Gbps throughput per port PCle 3 0 x8 host interface Based on the LSI SAS2208 6 Gbps ROC controller The IBM 6Gb Performance Optimized HBA has the following specifications Eight internal 6 Gbps SAS SATA ports Two x4 mini SAS internal connectors SFF 8087 Supports connections to SAS SATA HDDs and SATA SSDs Optimized for SSD performance No RAID support Up to 6 Gbps throughput per port PCle 2 0 x8 host interface Based on the LSI SAS2008 6 Gbps ROC controller For more information see the list of IBM Redbooks Product Guides in the RAID adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat raid IBM System x3630 M4 19 Drive options for internal storage The following table lists hard drive options for internal disk storage of the x3630 M4 server Table 9 Disk drive options for internal disk storage Part number Feature code Description Maximum supported 3 5 SAS Hot Swap HDDs 3 5 SAS Hot Swap HDDs 0 IBM 600GB 15K 6Gbps SAS 3 5
11. is compatibility tested and tuned for optimal System x performance and throughput IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime From a service and support standpoint IBM memory automatically assumes the IBM system warranty and IBM provides service and support worldwide The x3630 M4 supports DDR3 memory The server supports up to six DIMMs when one processor is installed and up to 12 DIMMs when two processors are installed Each processor has three memory channels and there are two DIMMs per channel The following rules apply when selecting the memory configuration e Mixing different types of memory UDIMMs RDIMMs and LRDIMMs is not supported e Mixing 1 5 V and 1 35 V DIMMs in the same server is supported in such cases all DIMMs operate at 1 5 V e The maximum number of ranks supported per one channel is eight with the exception of Load Reduced DIMMs where more than eight ranks are supported because one quad rank LRDIMM provides the same electrical load on a memory bus as a single rank RDIMM e The maximum quantity of DIMMs that can be installed in a server depends on the number of processors six DIMMs with one processor installed 12 DIMMs with two processors installed e All DIMMs in all processor memory channels operate at the same speed which is determined as the lowest value of e The memory speed supported by the specific processor
12. light patn LEDs path panel diagnostics panel Figure 10 Advanced level 2 light path for models with eight drive bays The following table lists the advanced light path kit Table 22 Advanced light path kit 30v6533 Lightpath Upgrade Ki IBM System x3630 M4 30 Supported operating systems The server supports the following operating systems Microsoft Windows Server 2012 Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 Datacenter x64 Edition Microsoft Windows Server 2008 Web x64 Edition Microsoft Windows Small Business Server 2008 Premium Edition Microsoft Windows Small Business Server 2008 Standard Edition Red Hat Enterprise Linux 5 Server Edition Red Hat Enterprise Linux 5 Server with Xen x64 Edition Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterprise Linux 6 Server Edition Red Hat Enterprise Linux 6 Server x64 Edition SUSE LINUX Enterprise Server 10 for AMD64 EM64T SUSE LINUX Enterprise Server 10 for x86 SUSE LINUX Enterprise Server 11 for AMD64 EM64T SUSE LINUX Enterprise Server 11 for x86 SUSE LINUX Enterprise Server 11 with Xen for AMD64 EM64T VMware ESX 4 1 VMware ESXi 4 1 VMware vSphere 5 VMware vSphere 5 1 For the latest information about the specific versions and service levels supported and any other prerequisites see the IBM ServerProven website at http www ibm com systems info x86servers serverproven compat us nos matrix shtml Physical and electrical specif
13. lower heat output and reduced cooling needs Locations of key components and connectors The following figure shows the front of the server with eight 3 5 inch drive bays 3 54nch hot swap drive bays 3 5 inch simple swap bays also available Light path Video USB2 0 Status Light path Optical button diagnostics port ports LEDs diagnostics drive panel optional din ad optional a Figure 2 Front view of the IBM System x3630 4 with eight drive bays The following figure shows the front of the server with twelve 3 5 inch drive bays 3 54nch hot swap drive bays Power Status Basic light path ports button LEDs diagnostics panel Figure 3 Front view of the IBM System x3630 4 with twelve drive bays IBM System x3630 M4 4 The following figure shows the rear of the server without the optional rear HDD cage upgrade PCle slot 5 PCle slot 4 PCle slot 3 PCle slot 2 PCle slot 1 550 W hot swap Dedicated management power supplies or data RJ 45 1 GbE network port standard Shared management data or dedicated data RJ 45 network ports 1 GbE network port optional via FoD standard Figure 4 Rear view of the IBM System x3630 4 without the rear HDD cage The following shows the rear of the server with the optional rear HDD cage upgrade Two 3 5 inch hot swap PCle slot 3 drive bays PCle slot2 PCle slot 1 750 W hot swap Dedicated management power supplies or data RJ 45 1 GbE network port standard Sha
14. security through hardware based resistance to malicious software attacks allowing an application to run in its own isolated space protected from all other software running on a system Energy efficiency The x3630 4 offers the following energy efficiency features to save energy reduce operational costs increase energy availability and contribute to a green environment IBM System x3630 M4 Energy efficient planar components help lower operational costs 80 PLUS Platinum certified power supplies enable greater energy savings while providing flexibility to meet your business needs The Intel Xeon processor E5 2400 product family offers better performance over the previous generation while fitting into the same TDP limits e Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw e Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments e Low voltage 1 35 V DDR3 memory RDIMMs consume 1996 less energy compared to 1 5 V DDR3 RDIMMs e The server uses hexagonal ventilation holes a part of IBM Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system e IBM Systems Director Active Energy Manager provides advanced data center power notification and management to help achieve
15. with one 550 W AC models with up to eight drive bays or 750 W AC storage rich models with up to 14 drive bays hot swap power supply IBM System x3630 M4 27 The following table lists the power supply options An AC hot swap power supply option ships standard with one 2 8m 10A 100 250V C13 to IEC 320 C14 rack power cable Table 18 Power supplies Part Feature Description Maximum Standard models number code supported where used 94Y6668 A1H6 IBM System x 550W High Efficiency Platinum 2 A2x A4x B2x C2x C4x AC Power Supply F4x G2x 946669 A1H5 IBM System x 750W High Efficiency Platinum 2 B4x C6x D2x F2x H2x AC Power Supply J2x 94Y6667 A2EB IBM System x 900W High Efficiency Platinum 2 AC Power Supply 94Y7631 9 IBM System 750W High Efficiency 48V DC 2 Power Supply Note If you plan to use GPU adapters refer to the GPU adapters section for the additional power supply selection guidelines Integrated virtualization The server supports VMware ESXi installed on a USB memory key The key is installed in a USB socket inside the server The following table lists the virtualization options Table 19 Virtualization options Part number Feature Description Maximum code supported 41Y8298 A2G0 IBM Blank USB Memory Key for VMware ESXi Downloads 41Y8300 A2NC IBM USB Memory Key for VMware vSphere 5 0 41Y8311 A2R3 IBM USB Memory Key for VMWare ESXi 5 1 Remote management The server contains IB
16. x8 wired low profile half length not present if optional x16 wired slot 3 riser is used the second processor is required to use this slot Slot 5 PCle 3 0 x8 x4 wired dedicated slot for ServeRAID adapter standard on hardware RAID models optional on software RAID models Up to three slots in models with 14 drive bays depending on the riser cards installed The slots are as follows e Slot 1 3 0 x8 x8 wired optional PCle 3 0 x16 x16 wired full height half length e Slot 2 PCle 3 0 x8 x8 wired low profile half length not present if an optional x16 wired slot 1 riser is used Slot 3 PCle 3 0 x8 x4 wired optional PCle 3 0 x8 x8 wired dedicated slot for ServeRAID adapter x8 wired slot requires the second processor x4 wired slot does not require the second processor Systems UEFI IBM Integrated Management Module II IMM2 Predictive Failure Analysis light path management diagnostics basic standard advanced optional Automatic Server Restart IBM Systems Director and IBM Systems Director Active Energy Manager and IBM ServerGuide Optional IMM Advanced FoD Upgrade for remote presence graphics keyboard and mouse and virtual media Security features Security features Power on password administrator s password and Trusted Platform Module TPM password administrator s password and Trusted Platform Module Power on password administrator s password and Trusted Platform Module TPM Video Matrox
17. your call following remote problem determination We provide service from 8 00 a m 5 00 p m in the client s local time zone Monday through Friday excluding IBM holidays In general the types of IBM ServicePac offerings are as follows e Warranty and maintenance service upgrades e One two three four or five years of 9x5 or 24x7 service coverage e Oncsite repair from next business day to 2 or 4 hours e One or two years of warranty extension e Remote technical support services One or three years with 24x7 coverage severity 1 or 9x5 next business day for all severities Installation and startup support for System x servers Remote technical support for System x servers Software support Support Line e Microsoft or Linux software e VMware e Systems Director IBM System x3630 M4 33 Regulatory compliance The server conforms to the following standards FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES 003 issue 4 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class Australia New Zealand AS NZS CISPR 22 Class A IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 GB9254 Class A GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST 51318 22 GOST R 51318 24 GOST R 51317 3 2 and GOST R 51317 3 3 CE Mark EN55022 Class A EN60950 1 EN55024 EN61000
18. 12 All rights reserved Note to U S Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp IBM System x3630 M4 48 This document was created or updated on June 21 2013 Send us your comments in one of the following ways e Use the online Contact us review form found at ibm com redbooks e Send your comments in an e mail to redbook us ibm com e Mail your comments to IBM Corporation International Technical Support Organization Dept HYTD Mail Station P099 2455 South Road Poughkeepsie NY 12601 5400 U S A This document is available online at http www ibm com redbooks abstracts tips0889 html Trademarks IBM the IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol or indicating US registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the International Business Machines Corporation in the United States other countries or both Calibrated Vectored Cooling Express St
19. 3 2 and EN61000 3 3 CISPR 22 Class A e TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 External disk storage expansion The x3630 4 supports attachments to the external storage expansion enclosures such as the EXP2500 series using the ServeRAID M5120 SAS SATA Controller The x3630 4 server can also be attached to supported external storage systems such as the IBM System Storage DS3500 series using the supported HBAs listed in Table 15 The following table provides the ordering part numbers for the ServeRAID M5120 SAS SATA Controller Table 24 Ordering part numbers and feature codes Part Feature Description Maximum number code supported 81Y4478 A1WX ServeRAID M5120 SAS SATA Controller for IBM System x 81Y4484 A1J3 ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade for IBM System x 2 81Y4487 1 4 ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade for IBM System x 2 One M5100 Series FoD software license is required per server Important The ServeRAID M5120 SAS SATA Controller ships standard without a cache One of the available cache upgrades 81Y4484 81Y4487 or 81Y4559 is required for the M5120 adapter operations and it must be purchased together with the controller IBM System x3630 M4 34 The ServeRAID M5120 SAS SATA Controller has the following specifications Eight external 6 Gbps SAS SATA ports Two external x4 mini SAS connectors SFF 8088 Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 w
20. 333 MHz 512 MB f 8 HS 2 7158 G2x 1 5 2450 8C 2 1GHz 1 4 GB 5110 8 3 5 Openbay 2x GbE 4 5 5 Optional 1 550 W 20MB 1600MHz 95W 1333 MHZz 1 GB f HS 8 2 7158 H2x 1 E5 2470 8C 2 3GHz 1x8 GB M5110 12x 3 5 Open bay 2x GbE 4 5 5 None 1x 750W 20MB 1600MHz 95W 1333 MHZz 1 GB f 14 HS 2 7158 J2x 1x E5 2450L 8C 1 8GHz 1 4 GB M5110 12x 3 5 Open bay 2x GbE 4 5 5 None 1x 750 W 20MB 1600MHz 70W 1333 MHZz 1 GB f HS 14 HS 2 x in the Machine Type Model MTM represents a country specific letter for example the EMEA MTM is 7158 A1G and the US MTM is 7158 A1U Ask your local IBM representative for specifics 1 Processor detail Processor quantity and model number of cores core speed L3 cache memory speed For models A2x A4x B2x and B4x the standard DIMM is rated at 1333 MHz but operates at up to 1066 MHz to match the processor memory speed Conversely for models G2x H2x and J2x the processor memory speed is rated at 1600 MHz but operates at up to 1333 MHz to match the rated speed of the installed DIMM Actual memory speed maximums depend on several factors as described in Memory options Models C4x and include Windows Storage Server 2008 R2 Standard preload f The ServeRAID M5110 RAID controller in this model includes flash backed cache 1x 550 W 1x 750 W HS 2 1x 550 W HS 2 1x 550 W HS 2 1x 750 W HS 2 I n N Refer to th
21. 35V PC3L 10600 CL9 ECC 12 6 per DDR3 1333MHz LP RDIMM processor 90Y3178 A24L 4GB 1x4GB 2Rx8 1 5V PC3 12800 CL11 ECC DDR3 12 6 per 1600MHz LP RDIMM processor 49Y1397 8923 8GB 1x8GB 2Rx4 1 35V PC3L 10600 CL9 ECC 12 6 per 4 C6x H2x 1333MHz LP RDIMM processor 90Y3109 A292 8GB 1x8GB 2Rx4 1 5V PC3 12800 CL11 ECC DDR3 12 6 per 1600MHz LP RDIMM processor 49Y1399 A14E 8GB 1x8GB 4Rx8 1 35V PC3L 8500 CL7 ECC DDR3 12 6 1066MHz LP RDIMM processor 49Y1563 A1QT 16GB 1x16GB 2Rx4 1 35V PC3L 10600 CL9 ECC 12 6 per DDR3 1333MHz LP RDIMM processor LRDIMMs 90Y3105 A291 32GB 1x32GB 4Rx4 1 35V PC3L 10600 CL9 ECC 12 6 per DDR3 1333MHz LP LRDIMM processor IBM System x3630 M4 14 Internal disk storage options The x3630 M4 server supports the following internal storage configurations Four 3 5 inch SATA simple swap drive bays Eight 3 5 inch SATA simple swap drive bays Eight 3 5 inch SAS SATA hot swap drive bays Twelve 3 5 inch SAS SATA hot swap drive bays Fourteen 3 5 inch SAS SATA hot swap drive bays In addition four and eight bay models support the installation of either an internal optical drive or an internal tape drive The following figure shows some of these configurations Eight 3 5 inch simple swap drive bays with optical drive Eight 3 5 inch hot swap drive bays with optical drive Twelve 3 5 inch hot swap drive bays Figure 7 Internal drive configuration
22. I IMM2 continuously monitors system parameters triggers alerts and performs recovery actions in case of failure to minimize downtime Built in diagnostics using Dynamic Systems Analysis DSA Preboot speeds up troubleshooting tasks to reduce service time Three year customer replaceable unit and on site limited warranty next business day 9x5 Optional service upgrades available Manageability and security Powerful systems management features simplify local and remote management of the x3630 M4 The server includes an Integrated Management Module II IMM2 to monitor server availability and perform remote management An integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error handling Integrated Trusted Platform Module TPM V1 2 support enables advanced cryptographic functionality such as digital signatures and remote attestation IBM Systems Director is included for proactive systems management It offers comprehensive systems management tools that help increase uptime reduce costs and improve productivity through advanced server management capabilities Industry standard AES NI support provides faster and stronger encryption Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system Intel Trusted Execution Technology provides enhanced
23. Intel C600 series Memory Up to 12 DIMM sockets six DIMMs per processor LRDIMMs RDIMMs and UDIMMs are supported but memory types cannot be intermixed DIMM speeds are up to 1600 MHz Memory With LRDIMMs Up to 384 GB with 12x 32 GB RDIMMs and two processors maximums With RDIMMs Up to 192 GB with 12x 16 GB RDIMMs and two processors With UDIMMs Up to 48 GB with 12x 4 GB UDIMMs and two processors ECC Chipkill memory mirroring and memory rank sparing Disk drive bays Up to eight 3 5 inch SATA simple swap drive bays up to eight 3 5 inch SAS SATA hot swap drive bays or up to fourteen 3 5 inch SAS SATA hot swap drive bays Maximum internal Up to 56 TB with 4 TB 3 5 inch NL SAS SATA HS HDDs up to 32 TB with 4 TB 3 5 inch storage SATA SS HDDs or up to 7 2 TB with 512 GB 3 5 inch SATA HS SSDs An intermix of SAS SATA is supported RAID support RAID 0 and 1 with C105 RAID 0 1 and 10 with M1115 or M5110 Upgrades to RAID 5 and 50 are available for M1115 Upgrades to RAID 5 and 50 are available for M5110 zero cache 512 MB battery backed cache 512 MB or 1 GB flash backed cache Upgrade to RAID 6 or 60 is available for M5110 with caches Optical drive bays One for models with up to eight 3 5 inch drive bays Support for optional DVD ROM multiburner Tape drive bays Optional for models with up to eight 3 5 inch drive bays Tape Enablement Kit is required to support the internal tape drive Support for optional DDS5 or DDS6 U
24. LP for B4x C2x C4x C6x D2x Slotless RAID F2x F4x G2x H2x J2x 90Y6383 A1ZH PCle Riser Card 2 1 x16 LP Slot 1 x4 LP for Slotless RAID Riser kit for Slot 2 with Slotless RAID This riser card is installed in all standard models It can also be used in CTO or special bid models Table 13 1U I O riser card options Part Feature Description Maximum Standard models number code supported where used 1U Riser 1 option supplies slots 1 and 2 12 PCle Riser 1 1 8 FH HL 1 x8 LP Slots PCle Riser 1 1 x16 FH HL Slot for Graphic card PCle Riser Card 2 1 x4 LP for Slotless RAID PCle Riser Card 2 1 x8 LP for Slotless RAID T These riser cards come standard with the 3 5 Hot Swap Cage Assembly Rear 2 x 3 5 option 0009034 This riser card is only available through CTO or special bid models Network adapters The x3630 M4 supports up to four integrated Gigabit Ethernet ports two enabled standard and two enabled optionally with the FoD upgrade Integrated NIC has the following features e Intel 350 CM2 chip e Up to four Gigabit Ethernet ports two enabled standard and two enabled optionally with the 90Y9314 FoD upgrade e NIC Teaming load balancing and failover IBM System x3630 M4 23 Ethernet Features 1 Gb Ethernet IEEE 802 3 802 3u and 802 3ab PHY specifications compliant Integrated PHY for 10 100 1000 Mbps for multispeed full and half duplex auto neg
25. M Integrated Management Module II IMM2 which provides advanced service processor control monitoring and an alerting function If an environmental condition exceeds a threshold or if a system component fails the IMM2 lights LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem Optionally the IMM2 also provides a virtual presence capability for remote server management capabilities The IMM2 provides remote server management through industry standard interfaces Intelligent Plattorm Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser IBM System x3630 M4 28 The optional IBM Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue screen capture features The remote presence feature provides the following functions e Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel regardless of the system state e Remotely accessing the server using the keyboard and mouse from a remote client e Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server e Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive The blue screen capture feature captures the video display
26. SB tape drives is available Network interfaces Up to four integrated Gigabit Ethernet 1000BASE T RJ 45 ports two ports enabled and an additional two ports require the optional software FoD upgrade to enable them Ports Two USB 2 0 and one DB 15 video not available on storage rich models port on the front Four USB 2 0 one DB 15 video one DB 9 serial and four RJ 45 GbE network ports on the rear Two internal USB ports one for embedded hypervisor one for internal USB tape drive IBM Calibrated Vectored Cooling with three redundant non hot swap fans each fan has two motors Power supply Up to two redundant hot swap 550 W HE AC 750 W HE AC or 900 W HE AC power supplies all AC power supplies are 80 PLUS Platinum certified or up to two redundant hot swap 750 W HE DC power supplies Hard drives hot swap models power supplies IBM System x3630 M4 7 Table 1 Standard specifications part 2 Components Specification expansion Up to five slots in models with up to 12 drive bays depending on the riser cards installed slots The slots are as follows Slot 1 PCle 3 0 x16 x8 wired optional PCle 3 0 x16 x16 wired full height full length Slot 2 PCle 3 0 x16 x8 wired full height half length not present if optional x16 wired slot 1 riser is used Slot 3 PCle 3 0 x16 x8 wired optional PCle 3 0 x16 x16 wired low profile half length the second processor is required to use this slot Slot 4 PCle 3 0 x16
27. Series Performance Accelerator for IBM System x A2MD ServeRAID M5100 Series SSD Caching Enabler for IBM System x 3876 IBM 6Gb Performance Optimized HBA The ServeRAID C105 is an onboard software RAID controller An FoD upgrade for ServeRAID C105 that supports eight SATA HDDs The ServeRAID M5100 Series Battery Kit 81Y4508 is only supported with ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade 81Y4484 t The ServeRAID M5100 Series RAID 6 Upgrade 81Y4546 requires RAID 5 Upgrade with caches 81Y4484 81Y4487 or 81Y4559 81Y4508 1 1 1 1 1 81Y4546 1 1 1 90Y4318 Part number 90Y4273 46M0912 The internal hardware RAID controller is installed into a dedicated PCle slot slot 3 for models with 14 drive bays or slot 5 for models with up to 12 drive bays See Table 12 and Table 13 PCI riser card options for more details IBM System x3630 M4 17 The following table lists drive types and internal drive bay configurations supported by the RAID controllers SAS HDDs include both SAS and NL SAS HDDs and SATA HDDs include both SATA and NL SATA HDDs Table 8 Drive types and internal drive bay configurations supported by the RAID controllers 8x3 5 in 12x3 5 in 14x 3 5 in hot swap hot swap hot swap sinple swap zem swap ee e Optimized HBA Requires an FoD upgrade for ServeRAID C105 that supports eight SATA HDDs 8 pack SATA Enabler part number 90Y4349 The ServeRAID C105 onboard cont
28. contents before the IMM restarts the server when the IMM detects an operating system hang condition A system administrator can use the blue screen capture to assist in determining the cause of the hang condition The following table lists the remote management option Table 20 Remote management option 90Y3901 A1ML IBM Integrated Management Module Advanced 1 Upgrade In the default UEFI configuration Ethernet port 2 is configured to be dedicated to remote access to the 2 If preferred you can change the UEFI setting so that remote access to the IMM2 is via Port 1 and also accessible to the operating system This Shared setting is also useful if you do not have a dedicated management network management and production networks are combined into a single network The following table shows this setting and its effect on the Ethernet ports Table 21 UEFI settings for remote access to the IMM UEFI mode Ethernet Port 1 Ethernet Ethernet Port 3 Ethernet Port 4 Port 2 optional optional IMM network interface port Production Ethernet IMM2 Production Production dedicated default dedicated Ethernet Ethernet IMM network interface port Shared Production Production Production Production shared Ethernet and IMM2 Ethernet Ethernet Ethernet Light path diagnostics panel The light path diagnostics panel allows system engineers and administrators to easily and quickly diagnose hardware problems on the IBM System x servers If a fai
29. e extension or withdrawal without notice and may not be available in all countries Contact your local IBM Global Financing representative for additional detail IBM System x3630 M4 46 Related publications and links For more information see these resources US Announcement Letter IBM System x3630 M4 http ibm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlfid 897 ENUS 1 12 095 IBM System x3630 M4 product page http www ibm com systems x hardware rack x3630m4 index html IBM System x3630 M4 Installation and User s Guide http ibm com support entry portal docdisplay Indocid MIGR 5090171 IBM System x3630 M4 Problem Determination and Service Guide http ibm com support entry portal docdisplay Indocid MIGR 5090165 ServerProven hardware compatibility page for the x3630 M4 http www ibm com systems info x86servers serverproven compat us xseries 7158 html IBM Redbooks Product Guides for IBM System x servers and options http www redbooks ibm com portals systemx Open amp page pgbycat IBM System x DDR3 Memory Configurator http www ibm com systems x hardware ddr3config Configuration and Option Guide http www ibm com systems xbc cog xREF IBM System x Reference Sheets http www redbooks ibm com xref IBM System x Support Portal http ibm com support entry portal http ibm com support entry portal Downloads Hardware Systems System x System x3530 4 IBM System Storage Interoperabi
30. e Specifications section for information about the standard features of the server IBM System x3630 M4 9 Express models The following table lists the express models Table 3 Express models MTM Intel Xeon processort Memory RAID Drive Drives Onboard Optical 2 maximum bays NIC drive std max Central and Eastern Europe CEE 7158 E1G 1x E5 2407 4C 2 2GHz 1x 4 GB M1115 8 3 5 Openbay 2xGbE 4 5 5 Mutti 1x 550W 10MB 1066MHz 80W 1333 MHz HS 8 burner HS 2 7158 E2G 1x E5 2420 6C 1 9GHz 1x8 GB M5110 8 3 5 Openbay 2xGbE 4 5 5 Multti 1x 550W 15MB 1333MHz 95W 1333 MHz HS 8 burner HS 2 7158 1x E5 2430 6C 2 2GHz 1x8 GB M5110 12x 3 5 2x 500 GB 2x GbE 4 5 5 None 1x 750W 15MB 1333MHz 95W 1333 MHz 512 MB f HS 14 7 2K SATA HS 2 7158 E4G 1 E5 2420 6C 1 9GHz 1x8 GB M5110 8 3 5 1x 500GB 2x GbE 4 5 5 Mutti 1x 550W 15MB 1333MHz 95W 1333 MHz HS 8 7 2 SATA burner HS 2 Europe excluding CEE 7158 E1G 1x E5 2407 4C 2 2GHz 1 4 M1115 8 3 5 Openbay 2xGbE 4 5 5 Multti 1x 550W 10MB 1066MHz 80W 1333 MHz HS 8 burner HS 2 7158 E2G 1x E5 2420 6C 1 9GHz 1x8 GB M5110 8 3 5 Openbay 2xGbE 4 5 5 Multti 1x 550W 15MB 1333MHz 95W 1333 MHz HS 8 burner HS 2 7158 E3G 1x E5 2430 6C 2 2GHz 1x8 GB M5110 12x 3 5 2x 500 GB 2x GbE 4 5 5 None 1x 750W 15MB 1333MHz 95W 1333 MHz 512 MB f HS 14 7 2K SATA HS 2 Middle East Africa 7158 E1G 1x E5 2407 4C 2 2GHz 1 4 GB M1115 8 3 5
31. ect s cash flow break even point Acquire your IBM technology today and begin to realize its benefits now An FMV lease can help you get the solution you need now with low monthly payments that better align up front costs with the anticipated return on investment ROI from the technology e Easy to acquire with affordable rates We offer one stop shopping for a total IT solution so you can acquire IBM hardware software services and the financing you need from one IT provider Plus we provide simple easy to understand contracts and quick approvals As the world s largest IT financing provider with an asset base of US 35 8 billion and over 125 000 customers IBM Global Financing offers highly competitive rates that promote low total cost of ownership TCO and low monthly payments IBM Global Financing operates in more than 50 countries Go to http ibm com financing for financing options in your country and to contact a local financing specialist IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients Rates and availability subject to client s credit rating financing terms offering type equipment and product type and options and may vary by country Non hardware items must be one time nonrecurring charges and are financed by means of loans Other restrictions may apply Rates and offerings are subject to chang
32. ent Standard models with hardware RAID adapters ServeRAID M1115 or M5110 ship with two 2U risers supplying all five slots See Table 10 for details The slot form factors with 1U risers models with the rear HDD cage assembly are as follows e Slot 1 PCle 3 0 x8 x8 wired optional PCle 3 0 x16 x16 wired full height half length e Slot 2 PCle 3 0 x8 x8 wired low profile half length not present if an optional x16 wired slot 1 riser is used e Slot 3 PCle 3 0 x8 x4 wired optional PCle 3 0 x8 x8 wired dedicated slot for ServeRAID adapter x8 wired slot requires the second processor x4 wired slot does not require the second processor IBM System x3630 M4 22 Note The 3 5 Hot Swap Cage Assembly Rear 2 x 3 5 option number 0009034 ships with two 1U risers supplying x8 wired slots 1 and 2 and x4 wired slot 3 See Table 10 for details The following two tables lists the I O riser card options the 2U riser options and the 1U riser options Table 12 2U I O riser card options Part Feature Description Maximum Standard models number code supported where used 2U Riser 1 option supplies slots 1 and 2 None A1ZE PCle Riser Card 1 1 x8 FH FL 1 x8 FH HL Slots A2x A4x B2x B4x C2x C4x C6x D2x F2x F4x G2x H2x J2x 90Y6381 A1ZG PCle Riser Card 1 1 x16 FH FL Slot 1 Riser Kit for Slot 1 2U Riser 2 option supplies slot 3 4 and 5 0008604 A1ZF PCle Riser Card 2 2 x8 LP Slots 1 x4
33. for DVD ROM or Multiburner This option includes one USB cable and one power cable The optical drive is ordered separately This option is mutually exclusive with 90Y6370 Tape Drive Cage assembly Note Option 00D9051 x3630 M4 ODD Cage assembly comes standard with every four or eight bay standard model listed in Table 2 Option 90Y6370 upgrades any four or eight bay model with an internal tape drive bay for DDS5 or DDS6 tape drives This option includes one USB cable and one power cable The tape drive is ordered separately This option is mutually exclusive with 90Y6370 ODD Cage assembly IBM System x3630 M4 16 RAID controllers The following table lists the RAID controllers and the additional options used for the internal disk storage of the x3630 M4 server Table 7 RAID controllers for internal storage code supported where used 81Y4448 81Y4542 A1X1 ServeRAID M1100 Series Zero Cache RAID 5 Upgrade 1 A347 ServeRAID M5110 SAS SATA Controller 1 C4x C6x D2x F2x F4x G2x H2x J2x 81Y4481 81Y4544 A1X2 ServeRAID M5100 Series Zero Cache RAID 5 Upgrade DENEN A1J3 ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade M C4x C6x D2x 1 4 ServeRAID M5100 Series 512 Flash RAID 5 Upgrade M F2x F4x 81Y4484 81Y4487 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade G2x H2x J2x A22bE ServeRAID M5100 Series Battery Kit A1X3 ServeRAID M5100 Series RAID 6 Upgrade t A2MC ServeRAID M5100
34. ications Dimensions and weight Height 86 mm 3 4 in Width 447 mm 17 6 in Depth 749 mm 29 5 in Weight e Minimum configuration 16 4 kg 36 2 Ib e Maximum configuration 28 2 kg 62 2 Ib Supported environment Air temperature Server on 5 C 40 C 41 0 F 104 F altitude 0 915 m 3 000 ft Server on 5 C 32 C 41 0 F 89 6 F altitude 915 2 134 m 7 000 ft Server on 5 C 28 C 41 0 F 82 4 F altitude 2 134 3 050 m 10 000 ft Server off 5 C 45 C 41 0 F 113 F Shipment 40 C 60 C 40 F 140 F IBM System x3630 M4 31 e Humidity e Server on 8 85 maximum dew point 24 C maximum rate of change 5 C hr e Server off 8 80 maximum dew point 27 C e Shipment 5 100 e Design to ASHRAE Class A3 ambient of 35 C 40 C with relaxed support e Support cloud like workload with no performance degradation acceptable Turbo Off e Under no circumstance can any combination of worst case workload and configuration result in system shutdown or design exposure at 40 e Electrical e Models with 900 W power supplies e 100to 127 nominal V ac 50 Hz or 60 Hz 10A e 200to 240 nominal V ac 50 Hz or 60 Hz 5 e Input kilovolt amperes kVA approximately e Minimum configuration 0 15 kVA e Maximum configuration 1 02 kVA e Models with 750 W hot swap power supplies e 100 127 nominal V 50 Hz o
35. is operational mode and supports only x4 based memory DIMMs If memory mirroring is used then DIMMs must be installed in pairs a minimum of one pair per each processor and a maximum of two pairs per processor and both DIMMs in a pair must be identical in type and size If memory rank sparing is used then two single rank or dual rank DIMMs must be installed per populated channel the DIMMs do not need to be identical In rank sparing mode one rank of a DIMM in each populated channel is reserved as spare memory The size of a rank varies depending on the DIMMs installed Chipkill memory mirroring and memory rank sparing modes are mutually exclusive Only one operational memory mode can be enabled on a server and it is a system wide setting IBM System x3630 M4 13 The following table lists the memory options available for the x3630 4 server Table 5 Memory options Part Feature Description Standard number code models where used UDIMMs 49Y1404 8648 4GB 1x4GB 2Rx8 1 35V PC3L 10600 CL9 ECC 12 6 per 1333MHz LP UDIMM processor 49Y1405 8940 2GB 1x2GB 1Rx8 1 35V PC3L 10600 CL9 ECC 12 6 per DDR3 1333MHz LP RDIMM processor 49Y1406 8941 4GB 1x4GB 1Rx4 1 35V PC3L 10600 CL9 ECC 12 6 per A2x A4x B2x DDR3 1333MHz LP RDIMM processor B4x C2x D2x F2x F4x G2x J2x 49Y1559 A28Z 4GB 1x4GB 1Rx4 1 5V PC3 12800 CL11 ECC DDR3 12 6 per 1600MHz LP RDIMM processor 49Y1407 8942 4GB 1x4GB 2Rx8 1
36. ith optional M5100 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade Supports 512 MB battery backed cache or 512 MB or 1 GB flash backed cache cache Up to 6 Gbps throughput per port PCle 3 0 x8 host interface Based on the LSI SAS2208 6 Gbps ROC controller Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures For more information see the IBM Redbooks Product Guide ServeRAID M5120 SAS SATA Controller for IBM System x at http www redbooks ibm com abstracts tips0858 html Open The ServeRAID M5120 SAS SATA Controller supports connectivity to the IBM System Storage external expansion enclosures listed in the following table Up to nine expansion enclosures can be daisy chained per one M5120 external port For better performance distribute expansion enclosures evenly across both M5120 ports Table 25 IBM System Storage external expansion enclosures Part number Description Maximum quantity supported per one M5120 174712 IBM System Storage EXP2512 Express 174724X IBM System Storage EXP2524 Express The external SAS cables listed the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS SATA Controller Table 26 External SAS cables for external storage expansion enclosures Part number Description Maximum quantity supported per one enclosure IBM System x3630 M4 35 The following table lists the drives su
37. l hardware Comprehensive systems management tools with the next generation Integrated Management Module II IMM2 make it easy to deploy integrate service and manage IBM System x3630 M4 1 Key features Backed by the IBM legendary worldwide service and support the x3630 M4 is developed quality tested and certified by IBM the leading vendor in technology patents for 17 years running IBM System x advancements in scalability reliability and performance can help your business innovate and thrive With more flexible configuration options energy efficient components and robust systems management tools the x3630 M4 is an innovative design by IBM that can deliver business value over the long term Scalability and performance The x3630 M4 offers numerous features to boost performance improve scalability and reduce costs e The Intel Xeon processor E5 2400 product family improves productivity by offering affordable dual socket system performance with eight core processors with up to 2 3 GHz core speeds up to 20 MB of L3 cache and one interconnect link of up to 8 GTps e Uptotwo processors 16 cores and 32 threads maximize the concurrent execution of multithreaded applications e Intelligent and adaptive system performance with Intel Turbo Boost Technology 2 0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power TDP e Intel Hyper Threading Technol
38. lity Center http www ibm com systems support storage ssic IBM System x3630 M4 47 Notices This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this document in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product program or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT
39. lure occurs a light is illuminated on the front panel of the server level 1 light path to alert the systems administrator that there is a problem The pop out light path diagnostics panel light path level 2 has a light against the failed subsystem This light directs the engineer or administrator directly to the failed component which also has an illuminated LED near it light path level 3 for example the DIMM error LED on the system board x3630 M4 offers two variants of light path diagnostics basic and advanced All standard x3630 M4 models include basic functionality that provides light path levels 1 and 3 Advanced functionality is optional and contains a pop out panel that adds light path level 2 Storage rich x3630 4 servers servers with 12 or 14 drive bays only support basic light path IBM System x3630 M4 29 The following figures show basic level 1 and advanced level 2 light path levels Power Ethemet Location Check System button LEDs button log error and LED andLED LED LED Figure 8 Basic level 1 light path for models with eight drive bays Power button and LED Location button and LED Check log LED System error LED Reset button Figure 9 Basic level 1 light path for storage rich models VER LINK B MEM Light path panel release reme ran SE latch BOARD Remind button Reset button Failed subsystem 1 light Light path
40. m as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Any performance data contained herein was determined in a controlled environment Therefore the results obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurement may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy modify and distribute these sample programs in any form without payment to IBM for the purposes of developing using marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM therefore cannot guarantee or imply reliability serviceability or function of these programs Copyright International Business Machines Corporation 20
41. mn fe pores 55 fe oros ses Fe piareon cieren torsen a 46M0907 5982 IBM 6Gb SAS HBA Controller 4 For more information see the list of IBM Redbooks Product Guides the Host bus adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat hba IBM System x3630 M4 26 PCle SSD adapters The server supports the High IOPS SSD adapters listed in the following table Table 16 SSD adapters code supported Hc a GPU adapters The server supports graphics processing units GPUs provided riser card 90Y6381 or FC A1ZB is installed The following table lists the supported GPUs Table 17 GPU adapters Part number Feature code Description Maximum supported None A13K NVIDIA Quadro 600 None A1QU NVIDIA Quadro 2000 945957 4798 NVIDIA Quadro 4000 This adapter can only be ordered through CTO or special bid The use of GPU adapters with 4x 3 5 inch or 8x 3 5 inch drive bay models requires installation of one or two 750 W power supplies The use of GPU adapters with 12x 3 5 inch or 14x 3 5 inch drive bay models requires installation of one or two 900 W power supplies 550 W power supplies are not supported with GPU adapters Power supplies The server supports up to two redundant hot swap 550 W AC 750 W AC 900 W AC or 750 W DC high efficient power supplies AC power supplies are 80 PLUS Platinum certified Standard models come
42. n 3 5 inch hot swap drive bays provide maximum internal storage density of up to 42 TB in a 2U form factor Availability and serviceability The x3630 4 provides many features to simplify serviceability and increase system uptime e server offers Chipkill memory mirroring and memory rank sparing for redundancy in the event of a non correctable memory failure to prevent an unplanned outage e Tool less cover removal provides easy access to upgrades and serviceable parts such as processor memory and adapter cards IBM System x3630 M4 2 The server offers simple swap hot swap drives supporting affordable software RAID and advanced hardware RAID redundancy for data protection and greater system uptime The server offers up to two redundant hot swap power supplies and three dual motor non hot swap redundant fans to provide cost efficient availability for applications The power source independent light path diagnostics panel and optional individual light path LEDs quickly lead the technician to failed or failing components This panel simplifies servicing speeds up problem resolution and helps improve system availability Predictive Failure Analysis PFA detects when system components processors memory hard disk drives fans and power supplies operate outside of standard thresholds and generates proactive alerts in advance of a possible failure therefore increasing uptime The built in Integrated Management Module I
43. n processort Memory RAID Drive Drives Onboard Optical 2 maximum bays drive Models announced May 2012 1x 550 W 7158 A2x 1x E5 2403 4C 1 8GHz 1 4 GB C105 4 3 5 Openbay 2 GbE 4 215 Optional 10MB 1066MHz 80W 1333 MHz 4 HS 2 7158 4 1 E5 2403 4C 1 8GHz 1 4 GB C105 8 3 5 Openbay 2x GbE 4 2 5 Optional 1x 550 W 10MB 1066MHz 80W 1333 MHz 8 HS 2 7158 B2x 1 E5 2407 4C 2 2GHz 1 4 GB C105 8 3 5 Openbay 2x GbE 4 2 5 Optional 10MB 1066MHz 80W 1333 MHz 8 7158 4 1 E5 2407 4C 2 2GHz 1 4 GB M1115 12x 3 5 Open bay 2x GbE 4 5 5 None 10MB 1066MHz 80W 1333 MHz HS 14 7158 C2x 1 E5 2420 6C 1 9GHz 1x4 GB M1115 8 3 5 Openbay 2 GbE 4 5 5 Optional 15MB 1333MHz 95W 1333 MHz HS 8 7158 C4x1 1x E5 2420 6C 1 9GHz 1x8 GB M5110 8 3 5 1x 500GB 2x GbE 4 5 5 Multi 15MB 1333MHz 95W 1333 MHz 512 MB 8 7 2 7158 C6x1 1x E5 2420 6C 1 9GHz 1x8 GB M5110 12x 3 5 1x 500GB 2 GbE 4 5 5 None 15MB 1333MHz 95W 1333 MHz 512 MB 14 7 2 SATA 7158 D2x 1 E5 2430 6C 2 2GHz 1 4 GB 5110 12x 3 5 Open bay 2 GbE 4 5 5 None 1x 750 W 15MB 1333MHz 95W 1333 MHz 512 MB HS 14 HS 2 7158 F2x 1x 5 2440 6C 2 4GHz 1 4 GB 5110 12x 3 5 Open bay 2x GbE 4 5 5 None 1x 750 W 15MB 1333MHz 95W 1333 MHz 512 MB f 14 HS 2 7158 F4x 1x E5 2440 6C 2 4GHz 1 4 GB 5110 8 3 5 Openbay 2x GbE 4 5 5 Optional 1 550 W 15 1333MHz 95W 1
44. ogy boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core e Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads e Intel Advanced Vector Extensions AVT improve floating point performance for compute intensive technical and scientific applications e The 12 RDIMMs of 1600 MHz DDR3 ECC memory provide speed high availability and a memory capacity of up to 384 GB running at 1066 MHz e The theoretical maximum memory bandwidth of the Intel Xeon processor E5 2400 product family is 38 4 GBps which is 2096 more than in the previous generation of Intel Xeon 5600 processors e server offers up to four integrated Gigabit Ethernet ports with convenient Feature on Demand upgrade process that does not require the purchasing of an additional hardware e server offers PCI Express 3 0 I O expansion capabilities that improve the theoretical maximum bandwidth by almost 10096 8 GTps per link using 128b 130b encoding compared to the previous generation of PCI Express 2 0 5 GTps per link using 8b 10b encoding e With Intel Integrated I O Technology the PCI Express 3 0 controller is integrated into the Intel Xeon processor E5 family This controller helps to reduce I O latency and increase overall system performance e Upto fourtee
45. or kits listed in the following table Table 35 Rack options For more information see the list of IBM Redbooks Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack IBM System x3630 M4 45 IBM Global Financing IBM Global Financing can help you obtain the IT solution you need while preserving funding for other strategic investments and optimizing cash flow Our Fair Market Value FMV lease helps ensure that you have the latest IBM technology and with our mid lease upgrade capability you can increase the capacity of the system with little to no change in monthly payments At the end of the lease take advantage of our flexible end of lease options to fit your changing business needs IBM Global Financing has the breadth and depth of offerings longevity proven success and global reach to help you develop a robust financing and asset management strategy that provides you the opportunity to use new technologies and turn your ambitious vision into a tangible solution Here are some other reasons why working with us makes solid financial sense e Expand your purchasing power Affordable monthly payments allow you to change the technology acquisition discussion from what can afford right now to what solution is really right for my business IBM Global Financing allows you to expand your purchasing power to get you the right solution e Accelerate your proj
46. orage IBM Systems Director Active Energy Manager IBM Redbooks Redbooks logo ServerProven ServicePac System Storage System x The following terms are trademarks of other companies Intel Xeon Intel Pentium Intel logo Intel Inside logo and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries LTO Ultrium the LTO Logo and the Ultrium logo are trademarks of HP IBM Corp and Quantum in the U S and other countries Microsoft Windows and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Other company product or service names may be trademarks or service marks of others IBM System x3630 M4 49
47. otiation IEEE 802 3x and 802 3z compliant flow control support with software controllable Rx thresholds and Tx pause frames Automatic cross over detection function MDI MDI X IEEE 1588 protocol and 802 1AS implementation IEEE802 3az Energy Efficient Ethernet EEE Full wake up support e Advanced Power Management APM support e Advanced Configuration and Power Interface ACPI specification v2 0c e Magic packet wake up enable Virtualization Features Eight transmit Tx and receive Rx queue pairs per port Flexible port partitioning 32 virtual functions VF with four ports or 16 VFs with two ports Rx Tx round robin scheduling Traffic isolation and traffic steering Virtual machine VM to VM packet forwarding packet loopback MAC and VLAN anti spoofing Malicious driver detection Storm control Per pool statistics off loads and jumbo support Independent Function Level Reset FLR for physical and virtual functions IEEE 802 1q Virtual Local Area Network VLAN support with VLAN tag insertion stripping and packet filtering for up to 4096 VLAN tags IEEE 802 1q advanced packet filtering Mirroring rules Support for simple VEPA VF promiscuous modes Stateless offload and performance features TCP UDP IPv4 checksum offloads Rx Tx Large send extended Tx descriptors IPv6 support for IP TCP and IP UDP receive checksum offload Tx segmentation offload IPv4 IPv6 Transmit Segmentation Offloading TSO
48. pported by EXP2512 external expansion enclosures Table 27 Drive options for EXP2512 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 3 5 inch NL SAS HS HDDs 49Y1903 1TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 49Y1902 2TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 12 90Y8720 3TB 7 200 rpm 6Gb SAS NL 3 5 HDD 3 5 inch SAS HS HDDs 49Y1899 300GB 15 000 rpm 6Gb SAS 3 5 HDD 12 49Y1900 450GB 15 000 rpm 6Gb SAS 3 5 HDD 12 12 49Y1901 600GB 15 000 rpm 6Gb SAS 3 5 HDD The following table lists the hard disk drives supported by EXP2524 external expansion enclosures Table 28 Drive options for EXP2524 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 2 5 inch NL SAS HS HDDs 49Y1898 500GB 7 200 rpm 6Gb SAS NL 2 5 HDD 24 4 81Y9952 1TB 7 200 rpm 6Gb SAS NL 2 5 HDD 2 2 5 inch SAS HS HDDs 49Y1896 146GB 15 000 rpm 6Gb SAS 2 5 HDD 81Y9944 300GB 15 000 rpm 6Gb SAS 2 5 HDD 81Y9596 600GB 10 000 rpm 6Gb SAS 2 5 HDD 81Y9948 900GB 10 000 rpm 6Gb SAS 2 5 HDD 2 2 2 2 24 4 4 4 2 5 inch SAS HS SSDs 81Y9960 400GB 2 5 SAS SSD IBM System x3630 M4 36 External disk storage systems The following table lists the external storage systems that are supported by the x3630 M4 serve and can be ordered through the System x sales channel The server may support other IBM disk systems that are not listed in this table For fu
49. r 60 Hz 8 9A e 200 240 nominal V AC 50 Hz or 60 Hz 4 5A e Input kilovolt amperes kVA approximately e Minimum configuration 0 14 kVA e Maximum configuration 0 90 kVA e Models with 550 W hot swap power supplies e 100 127 nominal V AC 50 Hz or 60 Hz 6 5A e 200 240 nominal V AC 50 Hz or 60 Hz 3 3A e Input kilovolt amperes kVA approximately e Minimum configuration 0 12 kVA e Maximum configuration 0 66 kVA e BTU output e Minimum configuration 406 Btu hr 119 watts e Maximum configuration 3480 Btu hr 1020 watts e Noise level e 6 6 bels operating e 6 6 bels idle IBM System x3630 M4 32 Warranty options The x3630 M4 has a three year on site warranty with 9x5 next business day terms IBM offers the warranty service upgrades through IBM ServicePac offerings which are described in this section An IBM ServicePac offering is a series of prepackaged warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions IBM ServicePac offerings are country specific that is each country might have its own service types service levels response times and terms and conditions Not all covered types of ServicePac offerings might be available in a particular country For more information about IBM ServicePac offerings available in your country visit the IBM Se
50. r DAC cables that must be purchased separately This adapter can only be ordered through CTO or special bid For more information see the list of Redbooks Product Guides in the Ethernet IB adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat networkadapters IBM System x3630 M4 25 Storage host bus adapters The following table lists storage HBAs supported by the x3630 M4 server Table 15 Storage adapters code supported eme wx Brocade 106b FC en wem xw Brocade 16 FO Dieron neater sem A vies ws emaer 16Gb Fo Daron Hea remsen 81Y1655 A2W5 Emulex 16Gb FC Single port HBA for IBM System x 00Y3337 A3KW QLogic 16Gb FC Single port HBA for IBM System x 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for IBM System x Fibre Channel 8 Gb 46M6050 3591 Brocade 8Gb FC Dual port HBA for IBM System x 46M6049 3589 Brocade 8Gb FC Single port HBA for IBM System x 42D0494 3581 Emulex 8Gb FC Dual port HBA for IBM System x 42D0485 3580 Emulex 8Gb FC Single port HBA for IBM System x 42D0510 3579 QLogic 8Gb FC Dual port HBA for IBM System x 42D0501 3578 QLogic 8Gb FC Single port HBA for IBM System x Fibre Channel 4 Gb 59Y1993 3886 Brocade 4Gb FC Dual port HBA for IBM System x 59Y1987 3885 Brocade 4Gb FC Single port HBA for IBM System x 42C2071 1699 Emulex 4Gb FC Dual Port PCI E HBA for IBM System x aas wes _ endoxsGoc perenn tor emsre
51. red management data or dedicated data RJ 45 network ports 1 GbE network port optional via FoD standard Figure 5 Rear view of the IBM System x3630 4 with the rear HDD cage IBM System x3630 M4 The following figure shows the locations of key components inside the server PCle slots s RAID controller Processor2 RAID controller 3and4 in dedicated slot and six DIMM battery or flash on riser 2 slots supercap PCle slot 5 on riser 2 dedicated for interna RAID controller te Slot for riser 2 Slot for riser 1 USB port for hypervisor PCle slots 1 and2 on riser 1 Processor 1 Redundant 3 54nch and six DIMM X non hot swap drive slots system fans bays Figure 6 Inside view of the IBM System x3630 M4 IBM System x3630 M4 Standard specifications The following table lists the standard specifications Table 1 Standard specifications part 1 Processor Up to two Intel Xeon processor E5 2400 product family processors with eight cores up to 2 3 GHz six cores up to 2 4 GHz or four cores up to 2 2 GHz one QPI link up to 8 0 GTps up to 1600 MHz memory speed up to 20 MB L3 cache or one Intel Xeon processor E5 1400 product family processor with four cores up to 2 8 GHz 10 MB L3 cache and 1333 MHz memory speed CTO only or one Intel Pentium processor 1400 product family processor with two cores up to 2 8 GHz 5 MB L3 cache and 1066 MHz memory speed CTO only
52. roller has the following specifications e Supports up to eight up to four standard with an additional four with optional 8 pack enabler 90Y4349 SATA HDDs SAS not supported Supports hot swap and simple swap drives Support for RAID 0 and RAID 1 non RAID is not supported Up to 3 Gbps throughput per port Support for up to two volumes Support for virtual drive sizes greater than 2 TB Fixed stripe unit size of 64 KB Support for MegaRAID Storage Manager management software IBM System x3630 M4 18 The ServeRAID H1110 adapter has the following specifications Four internal 6 Gbps SAS SATA ports One x4 mini SAS internal connector SFF 8087 Up to 6 Gbps throughput per port Based on the LSI SAS2004 6 Gbps RAID on Chip ROC controller PCle 2 0 x4 host interface Supports RAID 0 1 1E and 10 Connects to up to four SAS or SATA drives SAS expanders are not supported The ServeRAID M1115 SAS SATA Controller has the following specifications Eight internal 6 Gbps SAS SATA ports Two x4 mini SAS internal connectors SFF 8087 Supports connections to SAS SATA drives and SAS Expanders Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with optional M1100 Series RAID 5 upgrades Up to 6 Gbps throughput per port PCle 2 0 x8 host interface Based on the LSI SAS2008 6 Gbps ROC controller The ServeRAID M5110 SAS SATA Controller has the following specifications Eight internal 6 Gbps SAS SATA ports Two x4 mini SAS
53. rther information refer to the IBM System Storage Interoperability Center at http www ibm com systems support storage ssic Table 29 External disk storage systems For more information see the list of IBM Redbooks Product Guides in the System Storage category http www redbooks ibm com portals systemx Open amp page pg amp cat externalstorage IBM System x3630 M4 37 External backup units The server supports the external backup attachment options listed in the following table Table 30 External backup options Part 1 IBM System x3630 M4 38 Table 30 External backup options Part 2 External backup units Note The external tape drives listed can be ordered through the IBM System x sales channel The server may support other IBM tape drives that are not listed in this table For further information refer to the IBM System Storage Interoperability Center T Note These part numbers are the tape drives options for 35732UL and 35734UL For more information see the list of IBM Redbooks Product Guides in the Backup units category http www redbooks ibm com portals systemx Open amp page pg amp cat tape IBM System x3630 M4 39 Top of rack Ethernet switches The server supports the top of rack Ethernet switches from IBM System Networking listed in the following table Table 31 IBM System Networking Top of rack switches IBM System Networking 1 Gb top of rack switches For more information see the list of
54. rvicePac Product Selector at https www 304 ibm com sales gss download spst servicepac The following table explains warranty service definitions in more detail Table 23 uU c ae service definitions Tem Description IBM on site A service technician comes to the server s location for equipment repair repair IOR 24x7x2 hour A service technician is scheduled to arrive at your client s location within two hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 24x7x4 hour A service technician is scheduled to arrive at your client s location within four hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 9x5x4 hour A service technician is scheduled to arrive at your client s location within four business hours after remote problem determination is completed We provide service from 8 00 a m 5 00 p m in the client s local time zone Monday through Friday excluding IBM holidays If after 1 00 p m it is determined that onsite service is required the client can expect the service technician to arrive the morning of the following business day For noncritical service requests a service technician arrives by the end of the following business day 9x5 next A service technician is scheduled to arrive at your client s location on the business day after we business day receive
55. s IBM System x3630 M4 15 Backplanes Standard models ship with four or eight 3 5 inch SATA simple swap drive bays or eight 3 5 inch SAS SATA hot swap drive bays Storage rich models ship with twelve 3 5 inch SAS SATA hot swap drive bays and they can also be upgraded to fourteen 3 5 inch hot swap drive bay models with the optional rear HDD cage assembly The following table shows the internal storage expansion options that are available Table 6 Internal storage expansion options Part Feature Description Maximum Standard models number code supported where used 0009034 A1Z9 3 5 Hot Swap Cage Assembly Rear 2 x 3 5 0009051 A1zL 3630 M4 ODD Cage assembly A2x A4x B2x C2x F4x G2x 90Y6370 A1ZM USB Tape Drive Cage assembling kit Option 00D9034 is used to upgrade standard see Table 2 or custom CTO or special bid models with twelve 3 5 inch hot swap drive bays to fourteen 3 5 inch hot swap drive bays This option contains the HDD backplane drive cage signal and data cables and two 1U riser cards PCle Riser Card 1 1 x8 FH HL 1 x8 LP Slots and PCle Riser Card 2 1 x4 LP for Slotless RAID These 1U riser cards replace the standard 2U riser cards used in the models with twelve 3 5 inch hot swap drive bays limiting the maximum number of I O slots to three for more information see the I O expansion options section Option 00D9051 upgrades any four or eight bay model with an internal optical drive bay
56. talled into two riser sockets on the system planar one riser socket supports the installation of one riser card There are two types of riser cards 2U risers and 1U risers 2U risers are used in x3630 M4 models that do not have the rear HDD cage assembly see Figure 4 1U risers are used in models with the rear HDD cage assembly installed see Figure 5 See Figure 4 and Figure 5 for slot locations and numbering Note You cannot use 1U risers in models without the rear HDD cage You cannot use 2U risers in models with the rear HDD cage assembly installed The slot form factors with 2U risers models without the rear HDD cage assembly are as follows e Slot 1 PCle 3 0 x16 x8 wired optional PCle 3 0 x16 x16 wired full height full length e Slot 2 PCle 3 0 x16 x8 wired full height half length not present if optional x16 wired slot 1 riser is used e Slot 3 PCle 3 0 x16 x8 wired optional PCle 3 0 x16 x16 wired low profile half length the second processor is required to use this slot e Slot 4 PCle 3 0 x16 x8 wired low profile half length not present if optional x16 wired slot 3 riser is used the second processor is required to use this slot e Slot 5 PCle 3 0 x8 x4 wired dedicated slot for ServeRAID adapter standard on hardware RAID models optional on software RAID models Note Standard models with software RAID ServeRAID C105 ship with one 2U riser supplying slots 1 and 2 slots 3 4 and 5 are not pres
57. this model includes flash backed cache IBM System x3630 M4 10 Processor options The x3630 M4 supports the processor options listed in the following table The server supports up to two Intel Xeon processor E5 2400 product family processors one Intel Xeon processor E5 1410 one Intel Pentium processor 1403 or one Intel Pentium processor 1407 This table shows which server models have each processor standard If there is no corresponding where used model for a particular processor then this processor is only available through CTO Table 3 Processor options where used Single or dual processor support Intel Xeon processor E5 2400 product family D2x 90Y6362 Intel Xeon Processor E5 2440 6C 2 4GHz 15MB Cache 1333MHz 95W F2x F4x 90Y6361 Intel Xeon Processor E5 2450 8C 2 1GHz 20MB Cache 1600MHz 95W G2x 90Y6368 Intel Xeon Processor E5 2450L 8C 1 8GHz 20MB Cache 1600MHz 70W J2x 90Y6356 Intel Xeon Processor E5 2470 8C 2 3GHz 20MB Cache 1600MHz 95W H2x Single processor support only Intel Xeon processor E5 1410 and Intel Pentium processor 1400 product family None Intel Pentium Processor 1403 2C 2 6GHz 5MB cache 1066MHz 80W None Intel Pentium Processor 1407 2C 2 8GHz 5MB cache 1066MHz 80W None Intel Xeon Processor E5 1410 4C 2 8GHz 10MB Cache 1333MHz 80W These processors only support single processor configurations and are available only through CTO or special bid IBM System x3630 M4 11 Memory options IBM DDR3 memory