1. Date of Last Battery Date set at factory Reset this date when the battery module is replaced Replacement Audible Alarm On On Off The UPS will mate all audible alarms if this is set to Off or when the display keys are pressed B e Never attery On start up and every Self Test Interval 14 days since the last e Start up only e Frequency of test The interval at which the UPS will execute a self test Setting test every 7 to 14 days Reset to Fact eset to Factory No Yes No Restore the UPS factory default settings Default Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Main Outlet Group and Controlled Outlet Group Overview The Main Outlet Group and the Controlled Outlet Group can be configured to independently turn off turn on shut down and reboot connected equipment These features are not available on the 500 VA or 750 VA units The Main and Controlled Outlet Groups can be configured to do the following e Turn off Disconnect from power immediately and restart only with a manual command e Turn on Connect to power immediately e Shutdown Disconnect power in sequence and automatically reapply power in sequence when utility power becomes available e Reboot Shut down and restart In addition the Main Outlet Group and the Controlled Outlet Group can be configured to do the following Turn on or off in a specified sequence e Automatically turn off
2. NMC IP Address if NMC is available Estimated Runtime e Battery Voltage Configure advanced UPS settings Language e Battery Install Date e Local Power Quality e Reset Energy Meter e Menu Type e Enter Setup Wizard e Audible Alarm e Firmware Update standby mode Configuration e Display Auto Dim Auto Off Always On e Reset to Factory Default e Sensitivity e Config Main Group Outlets Low Transfer Config Group 1 Outlets if Controlled Outlet is e High Transfer available e Low Battery Warning e Config NMC if NMC is available e Auto Self Test Control Control the Main and Switched Outlet Group to turn on turn off shutdown or reboot Perform UPS test and diagnostic functions Test amp Diags UPS Self Test UPS Alarms Test e Calibration Test Log View the event and error logs for information about UPS events and faults that have occurred View UPS information UPS Model NMC Model No e UPS Part No NMC Serial No UPS Serial No NMC Hardware Version UPS Manufacture Date NMC Manufacture Date About e Battery Part No e NMC MAC Address e Battery Install Date e SmartSlot FW 1 e Replace Battery by e SmartSlot FW 2 UPS Firmware 1 SmartSlot FW 3 e UPS Firmware 2 UPS Firmware 3 If NMC is available e UPS Firmware 4 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Configuration UPS Settings Start up Settings Configure these settings at
3. ne Operation Manual Smart UPS U interruptible Power Supply Tower 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Overview Product Description The APC by Schneider Electric Smart UPS is a high performance uninterruptible power supply UPS The UPS provides protection for electronic equipment from utility power blackouts brownouts sags and surges small utility power fluctuations and large disturbances The UPS also provides battery backup power for connected equipment until utility power returns to safe levels or the batteries are fully discharged This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site www apc com Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install operate service or maintain it The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed The following safety messages may appear throughout this manual to warn of potential hazards A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in equipment damage and
4. 6060660606060606 su0351b 2200 3000 VA 100 Vac 3000 VA 120 Vac 2200 3000 VA 230 Vac Ben 1 ao x7 ble il o E D Je Installation For UPS installation information refer to the Smart UPS Installation Guide 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower that is included with the UPS The Installation guide is also available on the Documentation CD included with the UPS and on the APC by Schneider Electric Web site www apc com 4 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Operation Connect Equipment CAUTION RISK OF EQUIPMENT DAMAGE e Adhere to all local and national electrical codes e Wiring should be performed by qualified electrician e Always connect the UPS to a grounded outlet Failure to follow these instructions can result in equipment damage 3 4 Note The 2200 3000 VA 100 Vac model UPS will charge to 90 capacity in the first four and a half hours of normal operation All other models will charge to 90 capacity in the first three hours of normal operation Do not expect full battery runtime capability during this initial charge period Connect equipment to the outlets on the rear panel of the UPS Connect the UP
5. 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower 15 APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways Visit the APC by Schneider Electric Web site to access documents in the APC by Schneider Electric Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC by Schneider Electric Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC by Schneider Electric Knowledge Base and using e support Contact the APC by Schneider Electric Customer Support Center by telephone or e mail Local country specific centers go to www apc com support contact for contact information For information on how to obtain local customer support contact the APC by Schneider Electric representative or other distributors from whom you purchased your APC by Schneider Electric product Select models are ENERGY STAR qualified CR ENERGY STAR For more information go to www apc com site recycle index cfm energy efficiency energy star O 2013 APC by Schneider Electric APC the APC logo and APC the APC logo Smart UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respecti
6. Runtime ee Configure this time using the LOAD SHED RUNTIME REMAINING setting Load Shed On Set the value in When the remaining runtime reaches this level the Runtime 120 sec a seconds Controlled Outlet Group will turn off Remaining e Disabled In the event of an overload greater than 107 Load Shed on Enabled output the Controlled Outlet Group will Overload Disabled immediately turn off to conserve power for critical loads The Controlled Outlet Group will only turn on again with a manual command Network Management Card Settings These settings are available only on units that have a Network Management Card NMC and are set at the factory These settings can only be modified using an external interface such as the NMC Web interface e NMC IP Address Mode e NMC IP Address e NMC Subnet Mask e NMC Default Gateway Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower 11 Emergency Power Off Overview The Emergency Power Off EPO option is a safety feature that will immediately disconnect all connected equipment from utility power The UPS will immediately shut down and will not switch to battery power Adhere to all national and local electrical codes Wiring must be performed by a qualified electrician Connect each UPS to the EPO switch In configurations where multiple units are connected in parallel each UPS must be connected to the EPO switch The UPS must be restarted for p
7. initial start up using the display interface As an alternative configuration can be performed using PowerChute software Note During start up use the display interface to configure these settings If nothing is selected the unit will use the default settings Function Factory Default Options Description English e French The language for the display interface e German Language English e Spanish e Italian e Portuguese Language options will vary by model e Japanese e Good Select the quality of input utility power e Fair e If Good is selected the unit will go on battery power e Poor more often to provide the cleanest power supply to the Local Power Good connected equipment Quality If Poor is selected the UPS will tolerate more fluctuations in power and will go on battery power less often If unsure of the local power quality select Good The Standard menus display a limited set of menus Standard or i Menu Type Standard and options The advanced menus include all Advanced parameters General Settings Configure these settings at any time Use the display interface or PowerChute software Function Factory Default Options Description 100 Vac 108 Vac 108 Vac 114 Vac To avoid unnecessary battery usage set the transfer point higher if the utility voltage is chronically high and 120 Vac the connected equipment is known to work under this High Transfer Point 1
8. minor or moderate injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in equipment damage Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Read the Safety Guide supplied with this unit before installing the UPS e Adhere to all national and local electrical codes e This UPS is intended for indoor use only e Do not operate this UPS in direct sunlight in contact with fluids or where there is excessive dust or humidity e Be sure the air vents on the UPS are not blocked Allow adequate space for proper ventilation The battery typically lasts for two to five years Environmental factors impact battery life Elevated ambient temperatures poor quality utility power and frequent short duration discharges will shorten battery life e Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords e The equipment is heavy Always practice safe lifting techniques adequate for the weight of the equipment lt The model and serial numbers are located on a small rear panel label For some models an additional label is located on the chassis under the front bezel e Always recycle used batteries e Recycle the package materials or save them for reuse Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Specifications
9. utility voltage Check the utility power supply to the UPS by plugging in a table lamp If the light is very dim check the utility voltage The battery connector plug is not securely connected Be sure that all battery connections are secure There is an internal UPS fault Do not attempt to use the UPS Unplug the UPS and have it serviced immediately The UPS is operating on battery while connected to utility power The input circuit breaker has tripped Reduce the load on the UPS Disconnect nonessential equipment and reset the circuit breaker There is very high very low or distorted input line voltage Move the UPS to a different outlet on a different circuit Test the input voltage with the utility voltage display If acceptable to the connected equipment reduce the UPS sensitivity UPS is emits intermittent beeps The UPS is operating normally None The UPS is protecting the connected equipment UPS does not provide expected backup time The UPS battery is weak due to a recent power outage or is near the end of its service life Charge the battery Batteries require recharging after extended outages and wear out faster when put into service often or when operated at elevated temperatures If the battery is near the end of its service life consider replacing the battery even if the replace battery indicator has not illuminated The UPS is experiencing an overload conditi
10. 27 Vac 127 Vac 136 Vac condition The Power Quality setting will automatically change this setting Note Use the Advanced Menus to configure this TA 253 Vac 265 Vac setting 253 Vac 8 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Function Factory Default Options Description 100 Vac 86 Vac 92 Vac Set the transfer point lower if the utility voltage is 92 Vac chronically low and the connected equipment can 120 V tolerate this condition This setting may also be adjusted ac Low Transfer Point 97 Vac 106 Vac using the power quality setting 106 Vac 230 Vac Note Use the Advanced Menus to configure this ika 196 Vac 208 Vac 208 Vac setting 100 Vac N A Nominal Output es NA 230 Vac models only Set the nominal output voltage of Voltage e 220 Vac the UPS to standby mode 230 Vac 230 Vac 240 Vac Select the level of sensitivity to power events that the UPS will tolerate e Normal The UPS will go on battery power more often to provide the cleanest power supply to the ree connected equipment Transfer Sensitivity Normal Normal Reduced Low lt Low The UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances set the sensitivity to Normal The UPS will emit dible al hen th ini Low Battery Warning 120 sec Set the value in seconds E R S ad runtime has reached this level
11. CTORS AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES SPECIFICALLY SEIT IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE WHETHER DIRECT OR INDIRECT LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUANTS CLAIMS BY THIRD PARTIES OR OTHERWISE NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT SEIT S LIABILITY FOR DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE EXCLUDED OR LIMITED BY APPLICABLE LAW To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Customers with warranty claims issues may access the SEIT worldwide customer support network through the SEIT Web site www apc com Select your country from the country selection drop down menu Open the Support tab at the top of the web page to obtain information for customer support in your region Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase Smart UPS 750 1000
12. E to exit a submenu and return to a main menu Standard menus The Standard menus are the most commonly used menus Menu General Functions View UPS information e Operating Mode e Battery Temp Efficiency e Input Status e Load Power e Output e Load VA Last Transfer e Battery Charge state Last UPS Self Test Estimated Runtime Configure UPS settings Language e Display Auto Dim Auto Off Always On Configuration Local Power Quality Good Fair Poor e Battery Install Date e Menu Type Standard or Advanced e Reset to Factory Default e Audible Alarm Perform UPS tests and diagnostic functions Test amp Diags e UPS Self Test UPS Alarms Test e Calibration Test View UPS information About UPS Model UPS Part No UPS Serial No UPS Manufacture Date e Battery Part No Battery Install Date e Replace Battery by e UPS Firmware 1 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Advanced menus The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced menus Menu General Functions View detailed UPS information e Operating Mode e Battery Temp Efficiency e Input e Load Power e Output Status e Load VA e Last Transfer e Load Amps e Last UPS Self Test Load Energy Outlet Group 1 if Controlled Outlet is available e Battery Charge state
13. For additional specifications refer to the APC by Schneider Electric Web site at www apc com Environmental Operating 0 to 40 C 32 to 104 E Temperature 15 to 45 C 5 to 113 F Storage charge UPS battery every six months Maximum Operating 3 000 m 10 000 ft Elevation Storage 15 000 m 50 000 ft Humidity 0 to 95 relative humidity non condensing 2 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Product Overview Front panel features O Display interface 500 750 1000 1500 VA 2200 3000 VA Bezel Battery Internal battery connector su0453a Rear panel features 500 VA to 1500 VA models USB port 500 750 VA 100 Vac Serial port 750 VA 120 Vac a Chassis ground screw SmartSlot bi Circuit breaker Of UPS input o Outlets cs 000000 o o ju 00000000 su0326b Q T B 1000 1500 VA 100 Vac 1000 1500 VA 120 Vac 1000 1500 VA 230 Vac ao eal 0 5 su0325c su0328c Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Internal or external battery connector a 5700 0 66 750 VA 230 Vac su0327b su0452a Rear panel features 2200 VA and 3000 VA models 2200 VA 120 Vac USB Port Serial port RUE Chassis ground screw SmartSlot Circuit breaker UPS input Outlets EPO connector a gt D Ld bo
14. S to the building utility power Always connect the UPS to a two pole three wire grounded source To use the UPS as a master ON OFF switch turn on all the equipment that is connected to the UPS Press the ON OFF button on the front panel of the UPS to turn on the UPS and all connected equipment See Main Outlet Group and Controlled Outlet Group on page 10 for information on how to configure the outlet groups O Ooo APP or DCE y A GH GE J su0441a Ro Rear Panel Features IE Q 69 Serial port Connect to a computer to use power management software USB port Connect to a computer to use power management software Note Serial and USB communication can not be used simultaneously Ground Screw The UPS features a ground screw for connecting the ground leads on transient voltage devices Prior to connecting a ground lead disconnect the UPS from utility power Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Display Panel Online LED UPS ON OFF key On Battery LED Site Wiring Fault LED Replace Battery LED Display interface UP DOWN arrow keys ENTER key ESCAPES o 1 0 EEN o E ES su0343a 0060660660606006 Using the display interface Use the UP DOWN arrow buttons to scroll through the main menu options Press ENTER to view the submenus under each main menu option Press ESCAP
15. d voltage potential SELV circuits are controlled by a switch or relay properly isolated from utility power To avoid damage to the UPS do not connect the EPO interface to any circuit other than a SELV circuit Use one of the following cable types to connect the UPS to the EPO switch e CL2 Class 2 cable for general use e CL2P Plenum cable for use in ducts plenums and other spaces used for environmental air e CL2R Riser cable for use in a vertical run in a floor to floor shaft e CLEX Limited use cable for use in dwellings and for use in raceways Installation in Canada Use only CSA certified type ELC extra low voltage control cable Installation in countries other than Canada and the USA Use standard low voltage cable in accordance with national and local regulations Note The EPO function is available only for 2200 3000VA models 12 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Troubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is n 0 output The unit has not been turned on Press the ON key once to turn on the UPS The UPS is not connected to utility power Be sure the power cable is securely connected to the unit and to the utility power supply The input circuit breaker has tripped Reduce the load on the UPS Disconnect nonessential equipment and reset the circuit breaker The unit shows very low or no input
16. es for shipping Not all units utilize an external battery pack 4 Write the RMA provided by Customer Support on the outside of the package 5 Return the unit by insured prepaid carrier to the address provided by Customer Support Transport the unit Shut down and disconnect all connected equipment Disconnect the unit from utility power Disconnect all internal and external batteries if applicable Py ee Follow the shipping instructions outlined in the Service section of this manual 14 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Two Year Limited Factory Warranty Schneider Electric IT Corporation SEIT warrants its products to be free from defects in materials and workmanship for a period of three 3 years excluding the batteries which are warranted for two 2 years from the date of purchase The SEIT obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products Repair or replacement of a defective product or parts thereof does not extend the original warranty period This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase Products may be registered online at warranty apc com SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user s or any third person
17. on Check the UPS load display Unplug unnecessary equipment such as printers Display interface LEDs flash sequentially The UPS has been shut down remotely through software or an optional accessory card None The UPS will restart automatically when utility power is restored The Fault LED is illuminated The UPS displays a fault message and emits a constant beeping sound Internal UPS fault Do not attempt to use the UPS Turn the UPS off and have it serviced immediately The Replace Battery LED is illuminated and the UPS beeps for one minute every five hours The battery has a weak charge Allow the battery to recharge for at least four hours Then perform a self test If the problem persists after recharging replace the battery The Replace Battery LED is flashing an d the UPS beeps once every 2 seconds The replacement battery is not properly connected Be sure that the battery connector is securely connected The UPS displays a site wiring fault message Wiring faults detected include missing ground hot neutral polarity reversal and overloaded neutral circuit If the UPS indicates a site wiring fault have a qualified electrician inspect the building wiring Applicable for 120 V units only Smart UPS 750 1000 15 00 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower 13 Service If the unit requires service do not return it to the dealer Follow these step
18. or shut down when various conditions occur Note If the Main and Controlled Outlet Groups are not configured all of the outlets on the unit will still provide battery backup power Using the Main and Controlled Outlet Groups The Main Outlet Group functions as a master switch It will turn on first when power is applied and shut down last when there is a power outage and battery runtime has been exhausted The Main Outlet Group must be turned on for the Controlled Outlet Group to turn on 1 Connect critical equipment to the Main Outlet Group 2 Connect peripheral equipment to the Controlled Outlet Group Nonessential equipment that should shut down quickly in the event of a power outage can be added to a short power off delay to conserve battery runtime Equipment that has dependent peripherals that must restart or shut down in a specific order should be connected to a separate outlet group Equipment that needs to reboot independently from other equipment should be added to a separate outlet group 3 Use the Configuration menus to set reaction of the Controlled Outlet Group in the event of a power outage 10 Smart UPS 750 1000 1500 2200 3000 VA 100 120 230 Vac 500 VA 100 Vac Tower Customize the Main and Controlled Outlet Groups Use the Configuration menus to change the Main Outlet Group and the Controlled Outlet Group settings Function Factory Default Options Description Name String Outlet G 1 Outle
19. ower to return to connected equipment Press the ON OFF key on the front panel of the UPS Adhere to all local and national electrical codes All wiring must be performed by a qualified electrician Normally open contacts 1 Ifthe EPO switch or relay contacts are normally open insert the wires from the switch or contacts at pins 1 and 2 of the EPO terminal block Use 16 28 AWG wire 2 Secure the wires by tightening the screws If the contacts are closed the UPS will turn OFF and power will be removed from the load Normally closed contacts 1 If the EPO switch or relay contacts are normally closed insert the wires from the switch or contacts at pins 2 and 3 of the EPO terminal block Use 16 28 AWG wire 2 Insert a wire jumper between pins 1 and 2 Secure the wires by tightening the three screws at positions 1 2 and 3 If the contacts are opened the UPS will turn OFF and power will be removed from the load Note Pin 1 is the power source for the EPO circuit it provides a few milliampere of 24 V power If the normally closed NC EPO configuration is used the EPO switch or relay should be rated for dry circuit applications the rating should be for low voltage and low current applications This normally implies the contacts are gold plated The EPO interface is a Safety Extra Low Voltage SELV circuit Connect the EPO interface only to other SELV circuits The EPO interface monitors circuits that have no determine
20. s 1 Review the Troubleshooting section of the manual to eliminate common problems 2 If the problem persists contact APC by Schneider Electric Customer Support through the APC by Schneider Electric Web site www apc com a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call APC by Schneider Electric Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA c If the unit is under warranty the repairs are free d Service procedures and returns may vary internationally Refer to the APC by Schneider Electric Web site for country specific instructions 3 Pack the unit in the original packaging whenever possible to avoid damage in transit Never use foam beads for packaging Damage sustained in transit is not covered under warranty a Always DISCONNECT THE UPS BATTERIES before shipping The United States Department of Transportation DOT and the International Air Transport Association IATA regulations require that UPS batteries be disconnected before shipping The internal batteries may remain in the UPS b External Battery Pack products are deenergized when disconnected from the associated UPS product It is not necessary to disconnect the internal batteri
21. s misuse negligence improper installation testing operation or use of the product contrary to SEIT s recommendations or specifications Further SEIT shall not be liable for defects resulting from 1 unauthorized attempts to repair or modify the product 2 incorrect or inadequate electrical voltage or connection 3 inappropriate on site operation conditions 4 Acts of God 5 exposure to the elements or 6 theft In no event shall SEIT have any liability under this warranty for any product where the serial number has been altered defaced or removed EXCEPT AS SET FORTH ABOVE THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE APPLICABLE TO PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF SEIT S RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT S SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES SEIT WARRANTIES EXTEND ONLY TO ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES IN NO EVENT SHALL SEIT ITS OFFICERS DIRE
22. t Group Bone Edit these names using an external interface such as the Network UPS Name String UPS Outlets Management Card Web interface Set the value in The amount of time the UPS or a Controlled Outlet Turn On Delay O sec Group will wait between receiving the command to seconds turn on and the actual startup e O sec UPS Outlets Set the yakin The amount of time the UPS or a Controlled Outlet Turn Off Delay e 90 sec Controlled Group will wait between receiving the command to seconds Outlet Groups turn off and the actual shut down g Set the value in The amount of time the UPS or a Controlled Outlet Reboot Duration 8 sec voi seconds Group must remain off before it will restart Minimum Return Set the value in The amount of battery runtime that must be available 0 sec before the UPS or a Controlled Outlet Group will Time seconds turn on after a shutdown e Enable When the unit switches to battery power the UPS e Disable will disconnect power to the Controlled Outlet Group to save battery runtime Load Shed On Disabled Battery Configure this delay time use the LOAD SHED TIME WHEN ON BATTERY setting Load Shed Time 1800 sec Set the value in The amount of time the outlets will function on when On Battery seconds battery power before they will turn off Enable When the battery runtime falls below the specified Load Shed On e Disable value the Controlled Outlet Group will turn off Disabled
23. ve owners EN 990 3534D 03 2013