Home

Moxa AWK-1121

image

Contents

1. Step 5 Test communications To use the AWK 1121 as a client device a wireless AP should first be established for the AWK 1121 to connect to Default SSIDs for Moxa devices are all the same so when connecting one Moxa device to another they should connect automatically For example if one configures the AWK 3121 as an AP and sets up the AWK 1121 as a client the devices should connect upon powering on To test the connection first power on the AWK 1121 and then ping the AP by entering the following command ping IP address of AWK 3121 and then press the Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make sure the connections are correct Panel Layout of the AWK 1121 Top Panel View a E a a ae me Grounding screw Terminal block for PWR1 and PWR2 RS 232 console port AUX antenna port System LEDs PWR FAULT and STATE LEDs LEDs for signal strength WLAN and LAN LEDs 10 100BaseT X RJ45 Port MAIN antenna port Screw hole for wall mounting kit DIN Rail mounting kit Mounting Dimensions unit mm Top Views 50 0 mm 2 0 in ul ww O SOL UIG p ww O S LL O 70 0 mm 2 8 in Front Views Side View Rear Views DIN Rail Mounting The aluminum DIN Rail attachment plate should be fixed to the back panel of the AWK 1121 when yo
2. the AWK 1121 s top Top View panel COI Ql aa o UE Front View AN ATTENTION Before connecting the AWK 1121 to the DC power inputs make sure the DC power source voltage is stable Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the AWK 1121 s top panel are used to connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Signal The AWK 1121 has one RS 232 8 pin RJ45 console port located on the front panel Use either an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa AWK 1121 s console port to your PC s COM port You may then use a console terminal program to access the AWK 1121 for console configuration RS 232 Connection Console Pinouts for 10 pin or 8 pin RJ45 10 Pin Description 8 Pin ee LEEETETI 1 8 NOTE 1 The pin numbers for male DB9 and DB25 connectors and hole numbers for female DB9 and DB25 connectors are labeled on the connector However the numbers are typically quite small so you may need to use a magnifying glass to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 pins are numbered LED
3. together e Keep input wiring and output wiring separate e Itis strongly advised that you label wiring to all devices in the system when necessary ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 or LPS and rated O P 12 to 48 VDC minimum 6 W 12 V 0 55 A to 48V 0 16 A 25 C ATTENTION Make sure the external power adaptor includes power cords and plug assemblies provided with the unit is certified and suitable for use in your country Grounding the Moxa AWK 1121 Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices J AN ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Redundant Power Inputs The 4 contact terminal block connector on the AWK 1121 s top panel is used for the AWK 1121 s two DC inputs The top and front views of the terminal block connector are shown here STEP 1 Insert the negative positive DC wires _ into the V V terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on
4. AWK 1121 Quick Installation Guide Moxa AirWorks First Edition December 2011 MOXA 2011 Moxa Inc All rights reserved Reproduction without permission is prohibited Overview Moxa s AWK 1121 WLAN Client is ideal for applications that are hard to wire too expensive to wire or use mobile equipment that connects over a TCP IP network The AWK 1121 is rated to operate at temperatures ranging from 0 to 60 C for standard models and 40 to 75 C for extended temperature models and is rugged enough for any harsh industrial environment Installation is easy with either DIN Rail mounting or distribution boxes The DIN Rail mounting ability wide operating temperature range and IP30 housing with LED indicators make the AWK 1121 a convenient yet reliable solution for any industrial wireless application Package Checklist Moxa s AWK 1121 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e 1 AWK 1121 e 1 Swivel type Antenna 2dBi RP SMA 2 4 amp 5GHz e 1 Quick Installation Guide e 1 Software CD e 1 Moxa Product Warranty Booklet e 1 Protective Cap Installation and Configuration Before installing the AWK 1121 make sure that all items in the Package Checklist are in the box In addition you will need access to a notebook computer or PC equipped with an Ethernet port The AWK 1121 has a default IP address that you must use w
5. Indicators The front panel of the Moxa AWK 1121 contains several LED indicators The function of each LED is described in the table below LED State Description Power is being supplied Green Power is not being supplied Blinking IP address cannot be got from DHCP slow j FAULT l server interval 1 sec Blinking IP address conflict interval 0 5 sec fast Normal status Software Ready Stare Green The AWK Search Utility has located the Red Green AWK interval 1sec Red Booting or Error condition Signal level 5 LEDs Reserved WLAN functions WLAN Ces WLAN s data communication is run WLAN is not in use or not working properly LAN port is active LAN Green Blinking Data is being transmitted LAN port is inactive Specifications WLAN Standards IEEE 802 11a b g for Wireless LAN IEEE 802 3u 10 100BaseT X for Ethernet LAN IEEE 802 3af for Power over Ethernet PoE models Only IEEE 802 1D w STP RSTP Spread Spectrum and DSSS with DBPSK DQPSK CCK 5 18 to 5 24 GHz IEEE 802 1X RADIUS TKIP and AES Transmission Rates 802 11b 1 2 5 5 11 Mbps Celene 6 9 12 18 24 36 48 54 Mbps General Protocols Proxy ARP DNS HTTP HTTPS IP ICMP SNTP TCP UDP RADIUS SNMP RTP TX Transmit Power for hardware revision 1 2 Typ 18 1 5 dBm 1 to 11 Mbps Typ 1841 5 dBm 6 to 24 Mbps Typ 1 1 5 dBm 36 Mbps Typ 1641 5 dBm 48 Mbps Typ 1641 5 dBm 54 Mbps 802 11a T
6. e keyhole shaped apertures of the Wall Mounting Plates before it is screwed into the wall STEP 3 Once the screws are fixed into the wall insert the four screw heads through the large opening of the keyhole shaped apertures and then slide the AWK 1121 downwards as indicated to the right Tighten the four screws for added stability mae SRS 8 Ls 8 SIGNAL Wiring Requirements WARNING Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa AWK 1121 WARNING Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowed for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the following items e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled
7. ed when the AWK 1121 operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installation is within a safety area which is covered by a lightning protection or surge arrest system AN ATTENTION This device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 12
8. hen connecting to the device for the first time Step 1 Select the power source The AWK 1121 is powered by a DC power input while the AWK 1121 PoE can also be powered by PoE Power over Ethernet The AWK 1121 PoE will use whichever power source you choose Step 2 Connect the AWK 1121 to a notebook or PC Since the AWK 1121 supports MDI MDI X auto sensing you can use either a straight through cable or crossover cable to connect the AWK 1121 to a computer If the LED indicator on the AWK 1121 s LAN port lights up it means the connection is established Step 3 Set up the computer s IP address Set an IP address on the same subnet as the AWK 1121 Since the AWK 1121 s default IP address is 192 168 127 253 and the subnet mask is 255 255 255 0 you should set the IP address of the computer to 192 168 127 xxx and subnet mask to 255 255 255 0 Step 4 Use the web based manager to configure AWK 1121 Open your computer s web browser and then type http 192 168 127 253 in the address field to access the homepage of the web based management Before the homepage opens you will need to enter the user name and password For first time configuration enter the default user name and password and then click on the Login button User name admin Password root AN ATTENTION For security reasons we strongly recommend changing the password To do so select Maintenance gt Password and then follow the on screen instructions
9. u take it out of the box If you need to reattach the DIN Rail attachment plate to the AWK 1121 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 STEP 2 Insert the top of the DIN Rail into theThe DIN Rail attachment unit will slot just below the stiff metal spring snap into place as shown below 2 metal za spring metal spring Mh DIN Rail To remove the AWK 1121 from the DIN Rail simply reverse Steps 1 and 2 Wall Mounting optional For some applications it may be more convenient to mount the AWK 1121 to a wall as illustrated below STEP 1 EE Remove the aluminum E DIN Rail attachment plate from the AWK 1121 and then attach the wall mount plates with M3 screws as gt shown in the adjacent 7 diagrams top T T plate 3 e bottom plate 4 3 STEP 2 6 0 mm Mounting the AWK 1121 to a wall requires 4 screws gt lt Use the AWK 1121 device with wall mount plates attached as a guide to mark the correct locations of es the 4 screws The heads of the screws should be less 3 5mm than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws NOTE Test the screw head and shank size by inserting the screw into one of th
10. yp 18 1 5 dBm 6 to 24 Mbps Typ 161 5 dBm 36 Mbps Typ 15 1 5 dBm 48 Mbps pT yp 1441 5 dBm 54 Mbps RX Sensitivity for hardware revision 1 2 802 11b 94 dBm 1 Mbps 92 dBm 2 Mbps 90 dBm 5 5 Mbps 85 dBm 11 Mbps 802 11g 88 dBm 6 to 24 Mbps 85 dBm 36 Mbps 75 dBm 48 Mbps 70 dBm 54 Mbps 802 11a 88 dBm 6 to 24 Mbps 85 dBm 36 Mbps 75 dBm 48 Mbps 70 dBm 54 Mbps Interface Default Antenna Antenna Connector Connection Console LAN Port ED Indicators Power Input Voltage 12 to 48 VDC redundant dual DC power inputs or 48 VDC Power over Ethernet IEEE 802 3af for PoE models Input Current 0 55A 16A 12 48VDC Protection Casing IP30 protection aluminum case Dimensions Weight nstallation Operating Temperature Standard models 0 to 60 C 32 to 140 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative 5 to 95 non condensing Humidity Regulatory Approvals Radio EN300 328 MC EN301 489 1 17 EMI FCC Part 15 status Details See http www moxa com warranty A ATTENTION The AWK 1121 is NOT a portable mobile device and should be located at least 20 cm away from the human body The AWK 1121 is NOT designed for the general public To deploy AWK 1121s and establish a wireless network safely a well trained technician is required for installation 11 AN ATTENTION Use the antennas correctly The 2 4 GHz antennas are need