Home
Edimax 500Mbps Nano PowerLine
Contents
1. NETWORKING PEOPLE TOGETHER HP 5101AC Quick Installation Guide 08 2012 v1 0 PRODUCT INTRODUCTION Thanks for purchasing the 500M Nano PowerLine Adapter with Integrated Power Socket This adapter enables you to set up a home network quickly and easily via your existing household electrical wiring without the need for complex configuration or additional cabling Please follow the steps in this guide to set up the network Package Contents Before you start using this product please check if anything is missing from the packaging and contact your dealer to claim the missing item s HP 5101AC Powerline adapter x 1 Quick installation guide x 1 CD with setup wizard user manual amp multi language QIG x 1 Ethernet cablex 1 HP 5101ACK Powerline adapter x 2 Quick installation guide x 1 CD with setup wizard user manual amp multi language QIG x 1 Ethernet cable x 2 About Your Product n LAN port connected ian Blinking LAN activity transferring data Off LAN port not connected The green indicator turns on and the yellow indicator blinks slowly when the device is detecting a powerline link The green indicator turns on and the yellow indicator blinks quickly to indicate data is being transferred over the powerline link Off No other PLC device detected D Powered on PWR Powered off Note The device will enter standby mode and all LEDs will extinguish after 5 seconds wi
2. be used on the same household electric wiring as 14Mbps amp 85Mbps powerline adapters Edimax HP 85XX series without interfering but are not able to communicate directly with 14Mbps and 85Mbps powerline adapters Creating a Powerline Network 1 Connect a powerline adapter to your router via Ethernet cable and then plug it into a power socket Internet XDSL Modem Ethernet 2 Connect another powerline adapter to your computer and then plug it into a power socket Note You can also connect the adapter to a printer set top box gaming console TV or other device with a network port to add the device into the powerline network 3 Make sure that the PLC and LAN LEDs light up on both PLC adapters 4 The computer and the router will be connected to the powerline network automatically Creating an Encrypted Powerline Network with Two Adapters Once both adapters have been successfully connected press the Group Reset button of each adapter for less than 3 seconds within 2 minutes The adapters will automatically generate a random password to encrypt the powerline network Group Reset Note Toadd additional adapters into the encrypted powerline network or to remove an adapter from the powerline network please refer to the user manual for more details e ifthe powerline adapter in your network does not feature a Group Reset or an Encrypt button you can use the utility software included in the C
3. direktiv 2004 108 EC 2009 125 EC Dette udstyr er i overensstemmelse med de vaesentligste krav og andre relevante forordninger i direktiv 2004 108 EC 2009 125 EC Tama laite tayttaa direktiivien 2004 108 EC 2009 125 EC oleelliset vaatimukset ja muut asiaankuuluvat m r ykset FORUSEIN OG G0 000 Q0 HEN G d EX C QO 9 Fc C PE 6 O O O O O dq G d 9 CE FE O Ande WEEE Directive amp Product Disposal E At the end of its serviceable life this product should not be treated as household or general waste It X should be handed over to the applicable collection point for the recycling of electrical and electronic equipment or returned to the supplier for disposal Declaration of Conformity We Edimax Technology Co Ltd declare under our sole responsibility that the equipment described below complies with the requirements of the European EMC directive 2004 108 EC Equipment 500Mbps Nano Powerline Adapter with Integrated Power Socket Model No HP 5101AC The following European standards for essential requirements have been followed EMC EN 55022 2010 Class B EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 55024 2010 EMF EN 50385 2002 Safety LVD EN 60950 1 2006 A11 2009 Edimax Technology Co Ltd No 3 Wu Chuan 3 Road Wu Ku Industrial Park New Taipei City Taiwan Date of Signature August 2012 Signature Printed Name Albert Chang Titl
4. on the CD ROM The software and specifications are subject to change without notice Please visit our website www edimax com for updates All brand and product names mentioned in this manual are trademarks and or registered trademarks of their respective holders Edimax Technology Co Ltd Add No 3 Wu Chuan 3rd Rd Wu Ku Industrial Park New Taipei City Taiwan Tel 886 2 77396888 Email sales edimax com tw Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation English Francais Cestina Polski Romana Pycckun Magyar Turkce VkpalHcbka EU Declaration of Conformity This equipment is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2009 125 EC Cet quipement est conforme aux exigences essentielles et autres dispositions de la directive 2004 108 EC 2009 125 EC Toto zarizeni je v souladu se z kladn mi pozadavky a ostatnimi pr slusnymi ustanoven mi sm rnic 2004 108 EC 2009 125 EC Urzadzenie jest zgodne z og lnymi wymaganiami oraz szczeg lnymi warunkami okreslonymi Dyrektywa UE 2004 108 EC 2009 125 EC Acest echipament este in conformitate cu cerintele esentiale si
5. D as an alternative For more details please refer to user manual EDIMAX NETWORKING PEOPLE TOGETHER COPYRIGHT Copyright Edimax Technology Co Ltd all rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without the prior written permission from Edimax Technology Co Ltd Edimax Technology Co Ltd makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties merchantability or fitness for any particular purpose Any software described in this manual is sold or licensed as is Should the programs prove defective following their purchase the buyer and not this company its distributor or its dealer assumes the entire cost of all necessary servicing repair and any incidental or consequential damages resulting from any defect in the software Edimax Technology Co Ltd reserves the right to revise this publication and to make changes from time to time in the contents hereof without the obligation to notify any person of such revision or changes The product you have purchased and the setup screen may appear slightly different from those shown in this QIG For more information about this product please refer to the user manual
6. alte prevederi relevante ale Directivei 2004 108 EC 2009 125 EC 3ro o6opynoBaHMe COOTBeTCTByeT OCHOBHbIM Tpe60BaHMsM M NONOKEHMUAM JlIMpekTMBbl 2004 108 EC 2009 125 EC Ez a berendez s megfelel az alapvet k vetelm nyeknek s m s vonatkoz ir nyelveknek 2004 108 EC 2009 125 EC Bu cihaz 2004 108 EC 2009 125 EC direktifleri zorunlu istekler ve diger h k mlerle ile uyumludur O6nagHaHHa BinnoBinae Bumoram i yMoBaM anpe xtusn 2004 108 EC 2009 125 EC Sloven ina Toto zariadenie sp a z kladn po iadavky a al ie pr slu n ustanovenia smern c 2004 108 EC Deutsch Espa ol Italiano Nederlands Portugu s Norsk Svenska Dansk Suomi 2009 125 EC Dieses Ger t erf llt die Voraussetzungen gem den Richtlinien 2004 108 EC 2009 125 EC El presente equipo cumple los requisitos esenciales de la Directiva 2004 108 EC 2009 125 EC Questo apparecchio conforme ai requisiti essenziali e alle altre disposizioni applicabili della Direttiva 2004 108 EC 2009 125 EC Dit apparaat voldoet aan de essenti le eisen en andere van toepassing zijnde bepalingen van richtlijn 2004 108 EC 2009 125 EC Este equipamento cumpre os requesitos ess nciais da Directiva 2004 108 EC 2009 125 EC Dette utstyret er i samsvar med de viktigste kravene og andre relevante regler i Direktiv 2004 108 EC 2009 125 EC Denna utrustning ar i verensst mmelse med de v sentliga kraven och vriga relevanta bestammelser i
7. e Director Edimax Technology Co Ltd 10 DIMAX NETWORKING PEOPLE TOGETHER Edimax Technology Co Ltd Edimax Technology Europe B V Edimax Computer Company 6F No 3 Wu Chuan 3rd Road Wu Gu Nijverheidsweg 25 5683 CJ Best 3350 Scott Blvd Bldg 15 Santa Clara New Taipei City Taiwan The Netherlands CA 95054 USA www edimax com
8. thout any data transfer including when the Ethernet cable is disconnected The Power LED will flash once every 15 seconds Green Yellow Description The integrated electrical socket enables additional terminal devices or multiple socket to be connected to the adapter just as a normal wall socket would This is a Fast Ethernet port for connecting to a Ethernet Port computer or other devices with a network port Creates an encrypted powerline network group automatically press the button for less than 3 seconds Group Reset Integrated Power Socket Leaves an encrypted powerline network group press the button for 5 8 seconds Restores the rM adapter to factory defaults rM the button for 10715 seconds GETTING STARTED Hardware Installation 1 Always plug the powerline adapter directly into a power socket Never plug it into a multiple socket or uninterruptible power supply UPS 2 If you need to use a multiple socket for additional network devices then connect the multiple socket to the integrated power socket of the adapter and plug the powerline directly into a power socket as shown below The power socket of the adapter features a filter function which is able to improve the data transmission in the network 3 Please note that 200Mbps Edimax HP 200x series and 500Mbps Edimax HP 500x series powerline adapters are able to communicate directly with one another 200Mbps and 500Mbps powerline adapters can
Download Pdf Manuals
Related Search
Related Contents
Harmony4 PowerCore Manual Deutsch Frequency Inverter Convertidor de Frecuencia Inversor de D-Light Sync Pak.indd GB - Multiplex Mpman PDV3000 Manual de Instruções Solar_Controller_User_Manual Transcend 1TB StoreJet 25M2 Copyright © All rights reserved.
Failed to retrieve file