Home

DataComm 45-0031-WH outlet box

image

Contents

1. products shall be installed and used only as indicated in DataComm Electronics product instruction sheets Instruction sheets are available online at www datacommelectronics com CAUTION For shock protection this device must be properly grounded Use copper wire only with this device Page 1 of 2 12 21 10 Rev 2 Installation Instruction Sheet 45 0031 WH Continued p DATACOM Innovative structured wiring IMPORTANT INSTRUCTIONS 888 223 7977 Read and understand all instructions www datacommelectronics com Follow all warnings and instructions marked on the product Do not use this product near water for example near a bath tub wash bowl kitchen sink laundry tub in a wet basement or near a swimming pool 7 SAVE THESE INSTRUCTIONS ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT TEMPLATE 45 0031 WH Recessed Low Voltage Media Plate with Duplex Receptacle co q CUT ALONG DOTTED LINE T ETL LISTED This product is patent protected by U S Patent numbers D553475 D554475 and 7390964 C pe vipenptchiy RoHS Compliant 3026001 Page 2 of 2 12 21 10 Rev 2 Instruction Installation Sheet DataComm Electronics 45 0041 WH Recessed Low Voltage Media Plate with Duplex Surge Suppressor R i eee AEPNOEUT AE WPN Parts Included Tools Needed DataComm Electronics Inc 45 0041 WH Recessed Low Voltage Media Plate 1 Drywall Saw aA O Old Work Electrical Box 2 6 Ft Tape Measure 888 223 7977 15 Amp 1
2. 25 Volt Duplex Surge Suppressor 3 Pencil Three 3 Wire Nuts 4 Screwdriver 770 662 8205 www datacommelectronics com Four 4 Screws ee T Use DataComm Electronics Recessed Low Voltage Media Plate with Duplex Surge Suppressor to install low voltage cables behind your flat panel TV your amplifier or other audio and video devices This media plate can be installed upright sideways IMPORTANT INSTRUCTIONS This product is designed for retrofit work only because the old workbox cannot be attached to a stud This product is designed to alert you if you ever lose surge protection The SurgeBloc Protects connected loads from potentially damaging voltage spikes surges caused by lightning strikes near the line or the switching of inductive loads on the line motor loads as well as from RFI radio frequency interference The SurgeBloc cannot survive or provide protection in the rare event of a direct lightning strike on the service power line The SurgeBloc alerts you to the failure of the surge protection component by means of an audible signal If alarm sounds device has received power surges in excess of its capacity and is no longer functioning as a surge protector To shut off alarm simply unplug the surge module and replace with a new SurgeBloc module to restore surge protection Note When alarm sounds and the module is removed the receptacle still functions as a normal duplex receptacle without surge protection WARNI
3. Instruction Installation Sheet DataComm Electronics 45 0031 WH Recessed Low Voltage Media Plate with Duplex Receptacle DATA COMM innovative structured wiring Parts Included Tools Needed DataComm Electronics Inc 1 45 0031 WH Recessed Low Voltage Media Plate 1 Drywall Saw T ee 2 Old Work Electrical Box 2 6 Ft Tape Measure 888 223 7977 3 15 Amp 125 Volt Tamper Resistant 3 Pencil 770 662 8205 Duplex Receptacle 4 Screwdriver www datacommelectronics com 4 Four 4 Screws Use DataComm Electronics Recessed Low Voltage Media Plate with Duplex Receptacle to install low voltage cables behind your flat panel TV your amplifier or other audio and video devices This media plate can be installed upright sideways IMPORTANT INSTRUCTIONS This product is designed for retrofit work only because the old workbox cannot be attached to a stud WARNING Before installing this product be sure the power is off by switching the circuit breaker to off or removing the fuse s Test the power to make sure the power is off Be sure to install the Media Plate with Duplex Receptacle in accordance with the National Electrical Code NEC and local codes Template Installation Instructions Fig 1 Top view shows needed space between the drywall and the studs Receptacle side of the media plate must be 3 from the stud but no more than 5 review picture carefully Fig 2 Using the template supplied see page 2 of instruction sheet trace
4. NG Before installing this product be sure the power is off by switching the circuit breaker to off or removing the fuse s Test the power to make sure the power is off Be sure to install the Media Plate with Duplex Surge Suppressor in accordance with the National Electrical Code NEC and local codes Template Installation Instructions Fig 1 Top view shows needed space between the drywall and the studs Receptacle side of the media plate must be 3 from the stud but no more than 5 review picture carefully Fig 2 Using the template supplied see page 2 of instruction sheet trace the opening needed Using a drywall knife cut a hole in the drywall the size of the template See Figure 1 before tracing your opening Fig 3 Run the source of power to the included workbox Fig 4 Using the supplied surge suppressor connect the Recessed Media Plate to the piece of 12 2 or 14 2 with ground UL approved building wire using the supplied three wire nuts Connect the hot line black wire to black wire neutral white wire to white wire and grounding green wire to the green or bare grounding wire For shock protection this UR UL recognized component receptacle must be properly grounded Caution use copper wire only with this receptacle Once you have wired the surge suppressor screw the suppressor into the work box until the receptacle is firmly secured Fig 5 Now use the four screws provided to secure the work box to the
5. mounting studs on the backside of the of the media plate Fig 6 Pull all video and audio cords through the recessed opening Starting with the receptacle side of the media plate slowing slide the plate into the opening Swing the opposite side of the plate into position until the entire media box is flush with the wall Now screw down the screws with wings these wings fasten tightly against the back of the drywall Switch on the circuit breaker to on or insert the fuse s Plug all necessary video and audio cables Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instructions Page 1 of 3 1 5 11 Rev 2 E OMM Innovative structured wiring 888 223 7977 www datacommelectronics com Installation Instruction Sheet 45 0041 WH Continued Surge Suppressor Specifications Clamping Response Time 1 Nanosecond 2 Pole 3 Wire Grounding Total Maximum Maximum Surge Peak Suppression 60 Hz Receptacle Surge Dissipation Current Voltage 1875W Replacement Surge Protection Module Hot Neutral peels 340 Joules 12 000 Amps 1 000 Volts Hot Ground Neutral Ground Remember in the event your surge unit alarm sounds simply remove the replaceable SurgeBloc The receptacle still functions as a normal duplex receptacle without surge protection The Replacement SurgeBloc module 1209 made by Cooper Wiring Devices can be ordered through a DataComm Electronics distributor your local electrical distributor o
6. r contact Cooper Wiring Devices Sales Department at 800 441 3177 or 45 31 Court Square Long Island NY 11101 Removing the SurgeBloc Module WARNING DataComm Electronics products shall be installed and used only as indicated in DataComm Electronics product instruction sheets Instruction sheets are available online at www datacommelectronics com CAUTION For shock protection this device must be properly grounded Use copper wire only with this device IMPORTANT INSTRUCTIONS Read and understand all instructions Follow all warnings and instructions marked on the product Do not use this product near water for example near a bath tub wash bowl kitchen sink laundry tub in a wet basement or near a swimming pool SAVE THESE INSTRUCTIONS ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT Page 2 of 3 1 5 11 Rev 2 Installation Instruction Sheet 45 0041 WH Continued TEMPLATE 45 0041 WH Recessed Low Voltage Media Plate with Duplex Surge Suppressor 7 1 8 ACTUAL SIZE DATA On 888 223 7977 www datacommelectronics com CUT ALONG DOTTED LINE 2 This product is patent protected by U S Patent numbers D553475 D554475 and 7390964 RoHS Compliant Page 3 of 3 db 3026001 ETL LISTED CONFORMS TO ULSTD 514C 1 5 11 Rev 2
7. the opening needed Using a drywall knife cut a hole in the drywall the size of the template See Figure 1 before tracing your opening Fig 3 Run the source of power to the included workbox Fig 4 Using the supplied duplex receptacle connect the hot line black wire to the brass colored terminal or screw and the neutral white wire to the silver colored terminal or screw Be sure to connect the grounding green or bare grounding wire to the green colored terminal screw For shock protection this UR UL recognized component receptacle must be properly grounded Caution use copper wire only with this receptacle Once you have wired the receptacle screw the receptacle into the work box until the receptacle is firmly secured Fig 5 Now use the four screws provided to secure the work box to the mounting studs on the backside of the of the media plate Fig 6 Pull all video and audio cords through the recessed opening Starting with the receptacle side of the media plate slowing slide the plate into the opening Swing the opposite side of the plate into position until the entire media box is flush with the wall Now screw down the screws with wings these wings fasten tightly against the back of the drywall Switch on the circuit breaker to on or insert the fuse s Plug all necessary video and audio cables Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instructions WARNING DataComm Electronics

Download Pdf Manuals

image

Related Search

Related Contents

GUIDE POUR iPAD  TELEVISOR A CORES MANUAL DE SERVIÇO  Panel PC Magelis - Universal y Performance  Severin KS 9805 freezer  HP 600 625 Notebook PC  Sangean WFT-1Da+    Philips HTS5110 User Guide Manual Pdf  14000 Series 1 Watt - Internal Antenna Quick  led video curtain series user`s manual  

Copyright © All rights reserved.