Home

Irox JKTG-4R weather station

image

Contents

1. C F Changes the unit of temperature in the display from C to F or vice versa MEMORY RESET Hold pressed for 3 seconds Resets all memories IN and CH1 CH5 The new recording now begins depending on the setting of the MIN MAX switch CH CHANNEL Press briefly changes to display of the next channel 1 gt 2 gt 3 gt 4 gt 5 1 etc Hold pressed for 3 seconds For the radio channel active on the display CH1 CH5 a sender search is started The three waves above the CH flash during the search process Only the sender of the channel displayed is searched for the others remain unaffected 31 Battery compartment 2 x 1 5 batteries of the size AM 4 resp AAA To open slide lid in the direction of the arrow indicated on the lid after the stand has been removed 3 PUTTING INTO OPERATION Put all radio sensors that you want to use into operation and place these in close proximity 1 2 metres to the reception device Open the battery compartment of the display device and remove all insulation strips If no batteries are in the device insert the 2 batteries UM 3 or AA 1 5 V in the correct polarity Now close the battery compartment Directly after the activation of the batteries all segments are displayed for a few seconds on the display The JKTG 4R then begins with the search of available sensors on all 5 channels As soon as the sensor is displayed correctly see
2. inferiore In caso di problemi tentate altri luoghi e precisamente sia per il sensore che per il dispositivo di visualizzazione Il radiosensore impermeabile Posizionare il sensore in base alle possibilit ma sarebbe meglio all asciutto e in un luogo ombroso 6 In commercio possibile acquistare ulteriori sensori da visualizzare sul ricevitore Per l impiego all esterno si consiglia di utilizzare sensori impermeabili da esterno Per visualizzare i dati di altri ambienti interni disponibile il sensore JKTG 4R della serie Instruments by J rg Kachelmann dotato di ampio display e realizzato nello stesso design dell indicatore principale 4 TERMOMETRO RADIO L utilizzo del sensore radio fornito molto semplice Aprire il vano delle batterie Selezionare il canale Attivare le batterie togliendo le strisce d isolamento oppure inserire le batterie facendo molta attenzione a rispettare la polarit Richiudere il vano delle batterie facendo attenzione alla guarnizione Altri radiosensori Irox compatibili con JKTG 4R sono 3 canali inseribile sui canali 1 2 0 3 HTS12C HTS33 HTS13 HTC13 5 canali inseribile su tutti e 5 i canali HTS55 JKR 1 HTS13 incluso nella fornitura del JKTG 4R e pu essere inserito sui canali 1 3 Nei sensori con termometro e igrometro nel JKTG 4R viene visualizzata solo la temperatura Visualizzazione stato di ricezione Il simbolo a forma di onda mostra lo stato dell
3. troppo elevata procedimenti di ricerca menzionati sopra relativi ad un sensore perso non hanno alcun influsso su tutti gli altri sensori presenti e perfettamente funzionati 48 5 1 2 Memoria MIN MAX n 7 Hia test a valori MIN MAX sono sempre presenti sul display sotto il valore attuale misurato SINISTRA temperatura minima pi bassa MIN DESTRA temperatura massima pi alta MAX La logica delle registrazioni descritta al paragrafo 2 2 Elementi di comando Attenzione In assenza di dati disponibili appaiono alcuni trattini Ci accade quando un canale non occupato oppure il sensore non viene pi rilevato 5 1 3 Fascia comfort La fascia comfort viene indicata esclusivamente con riferimento alla misurazione termoigrometrica dell indicatore principale sensori esterni rilevano e visualizzano solo la temperatura pertanto il calcolo della zona comfort per i canali CH1 CH5 non possibile Il grafico seguente illustra la logica 65 99 rel humidity 8 ASSISTENZA Quest apparecchio un nuovo prodotto di Irox Development Technology Tutte le indicazioni sono state effettuate e verificate rispetto ad un apparecchio perfettamente funzionante E possibile che subentrino modifiche e miglioramenti all apparecchio non inclusi nella presente documentazione per motivi legati alle esigenze di stampa In caso di incongruenze o indicazioni incomplete che rendono difficoltoso l uso o il funzionamento del
4. F Internal sensor 20 C to 50 C Measurement range humidity Maximum range 1 to 99 Resolution 0 1 C 0 2F 1 r H Measurement accuracy 1 C in the range of 5 C to 40 C 2 C in the remaining range 5 r F in the range of 30 80 at 5 C to 40 C 7 r F in the range of 20 90 at 5 C to 40 C Measurement frequency of radio sensor once every 60 secondes Power 2 pieces MA 4 or AAA 1 5V batteries Dimensions Weight w o stand Display unit 86g incl batteries 69 W x 107 H x 10 D mm CE Indice Introduzione Elementi di controllo 2 1 Display LCD 2 2 Elementi di comando Tasti Interruttori Vano batterie Messa in funzione Pagina 46 Termometro radio Pagina 47 Uso Pagina 49 5 1 Termoigrometro Pagina 49 5 1 1 Consultazione della temperatura per ciascun canale Pagina 49 5 1 2 Memoria MIN MAX Pagina 50 5 1 3 Fascia comfort Pagina 50 Sostituzione della batteria Pagina 51 Manutenzione del apparecchio Pagina 51 Assistenza Pagina 52 Dati tecnici Pagina 52 Pagina 42 Pagina 43 Pagina 43 Pagina 44 2 ELEMENTI DI CONTROLLO 2 1 DISPLAY LCD Tutte le funzioni vengono visualizzate su un display a cristalli liquidi LCD su 3 finestre CH chJ LL HE BB gt ABBA Soe ange dd HB Be a THB it Display a segmenti interi Canali di misurazione radio 1 5 misurazione attuale del canale selezionato sonda rad
5. Reception status in Chap 4 you can set up the sensor in the place where you want to effectively measure the outdoor temperature Under the most ideal conditions this can be up to 30 m away In reality however this is often less In the event of problems try out other places and do so both for the sensor and for the display device The radio sensor is weatherproof Nevertheless please place the sensor where possible in the dry and at any rate in the shade If you would like to display further sensors on the reception device you can purchase these from shops For outdoor use we recommend weatherproof sensors If you would like to display other interior spaces the sensor JKR 1 from the Instruments by J rg Kachelmann range is available in the same design as that of the display device and also has a large display 33 Table of contents Introduction Operating elements 2 1 LCD display 2 2 Keys Switch Battery compartment Putting into operation Radio thermometer Operation 5 1 Thermo hygrometer 5 1 1 Reading of the temperature from each channel 5 1 2 MIN MAX memory 5 1 3 Comfort zone Change of battery Care instructions Support Technical data display unit 2 OPERATING ELEMENTS 2 1 LCD DISPLAY All functions are depicted on the liquid crystal display LCD in 3 windows AUG e WAGE HB at a BB ct ae EE cag Wane do CH AGO 24 ABB at Full segment display Radio
6. channels 1 5 current measurement of the selected channel radio probe memory values min max of the selected channel battery status of the sender displayed Comfort Zone display of the comfort status of the measurement of the indoor thermo hygrometer Indoor thermo hygro QQ temperature and relative air humidity of the display device measures at the location where the device is used memory values min max of the indoor thermo hygrometer battery status of the display device T H SET For the IN measurement the MIN MAX values of the temperature or the relative air humidity are displayed below the current value With this key you can have the temperature or hygro memory displayed MIN MAX The MIN MAX memory is managed and recorded depending on the setting The setting applies for all 6 channels Pos 1 PERM From the last MEMORY RESET the MIN MAX recordings after the function drag indicator are recorded This recording is PERMANENT i e a new recording does not start until after a new MEMORY reset Pos 2 24 Hr If you choose this option the MIN MAX values for the last 24 28 hours in each case are recorded After expiry of this period the MIN MAX values that are older than 24 28 hours are removed from the memory As soon as you have selected this option we recommend that you start the memory recording in a defined way with a MEMORY RESET This then starts a recording that triggers internally an ela
7. di attivazione CH1 CH2 gt CH3 gt CH4 CH5 gt CH1 etc indipendentemente dalla presenza o meno di un sensore radio nel sistema Attenzione La misurazione M raffigurata sempre nella finestra inferiore mentre i canali 1 5 sono raffigurati in sequenza nella finestra superiore 6 SOSTITUZIONE DELLA BATTERIA a BATTERIA SEGNALAZIONE DI SOSTITUZIONE Le batterie hanno una durate di circa 8 12 mesi In base all utilizzo dell apparecchio e delle batteria adottate tale intervallo di tempo pu essere maggiore o minore Per evitare un interruzione improvvisa e indesiderata del funzionamento dell apparecchio in entrambe le finestre delle temperature con il relativo canale appare il simbolo della batteria Ci significa che le batterie del dispositivo di visualizzazione nella finestra IN o di un radiotrasmettitore nella finestra CHx sono questi scariche e devono essere sostituite Per la sostituzione delle batterie vedere il capitolo 2 messa in funzione Utilizzare esclusivamente nuove batterie e non mischiate mai batterie vecchie con quelle nuove Fate anche attenzione al fatto che le batterie usate non vanno gettate nella pattumiera domestica e che dovrebbero essere smaltite in un apposito luogo di raccolta L ambiente ve ne sar grato 7 MANUTENZIONE DEL APPARECCHIO Non esporre l apparecchio a temperature estreme o direttamente al sole per un lungo periodo Evitare urti violenti o colpi di qualunque tipo all apparec
8. gt 1 gt etc Tenendo premuto questo tasto per 3 secondi viene avviata la ricerca del trasmettitore per il canale radio visualizzato sul display CH1 CH5 Durante la ricerca le tre onde sopra al canale CH lampeggiano La ricerca riguarda solamente il trasmettitore del canale visualizzato mentre gli altri rimangono inalterati 44 Vano batteria 2 26 Hr 2 batterie da 1 5 AM 4 o AAA Apertura dopo aver rimosso il piedistallo spingere il coperchio nella direzione indicata dalla freccia raffigurata sul coperchio 3 MESSA IN FUNZIONE 1 Mettere in funzione tutti i sensori radio desiderati e disporli nelle vicinanze 1 2 m del dispositivo ricevitore 2 Aprire il vano batterie del dispositivo di visualizzazione e rimuovere tutte le strisce isolanti Se non sono presenti le batterie nell apparecchio inserire 2 batteria UM 3 o AA 1 5V con la polarit corretta 3 Richiudere il vano batterie 4 Immediatamente dopo l attivazione delle batterie appaiono sul display tutti i segmenti per pochi secondi subito dopo JKTG 4R inizia con la ricerca dei sensori disponibili per tutti i 5 canali 5 Non appena il sensore viene visualizzato correttamente vedi Stato del ricevitore al cap 4 possibile posizionare il sensore sul luogo nel quale si vuole effettivamente misurare la temperatura esterna e l umidit esterna In condizioni ideali il posizionamento pu avvenire fino a 30 m di distanza Nella realt numero
9. KSPO 1101 10 IROX OST14 MANUAL 3 Eng SIZE W100 x H100 mm BY Lai HZ 23 7 10 IROX JKTG 4R Operating Instructions 3 Rox ROX le Version 1 1 1 INTRODUCTION Meteocentrale ch is the weather forecast website operated by Meteomedia Ltd Meteomedia is one of the leading weather services in Europe and with its own Severe Weather Centres in Switzerland and in Germany among other things specialist for modern early warning systems for extreme weather conditions The core of the company is the private weather measurement network It is one of the biggest measurement networks in Europe Irox market leader in the manufacturing of measuring devices and Meteomedia have developed a joint product line that convinces with its high quality measurements simple handling and elegant design The JKTG 4R is a high quality thermo hygrometer that gives you the absolutely unique feature of choosing between three different max min memory functions The recording is done independently for each of the 6 channels in total The individual scanning of the 5 radio sensors also makes operation transparent and calculable Please read the instructions carefully They contain some useful and interesting information that go beyond a mere explanation of how to operate the device 2 2 KEYS SWITCH BATTERY COMPARTMENT Rear view MEMORY RESET PRODUCT CODE JKTG AR REF IRB 1068 20 anaso com o o
10. a ricezione del segnale del canale visualizzato L unit in modalit di ricerca MEN rilevamenti di temperatura A sono registrati in modo sicuro TEN Assenza di segnale Collisioni di segnale segnali radio di altri dispositivi nelle vicinanze possono causare delle interferenze e delle interruzioni temporanee della ricezione Ci non male ma in certi casi da fastidio Alcuni dei tipici dispositivi di disturbo possono essere alcuni rilevatori acustici impianti di allarme wireless schermi a raggi catodici PC TV telecomandi etc Il tali casi pu essere utile adoperare un altro canale 5 USO 5 1 TERMOIGROMETRO Il modello JKTG 4R misura direttamente la temperatura e l umidit relativa registrando al contempo le misurazioni di altri 5 sensori radio di temperatura IROX Ciascun sensore deve essere impostato su uno dei canali 1 5 oppure sui canali 1 3 per apparecchi a 3 canali Il display indica la temperatura attuale rilevata in C o in F mentre nel punto in cui si trova l indicatore principale sono indicate anche l umidit atmosferica relativa in e la fascia comfort possibile eseguire i seguenti comandi in questa funzione 5 1 1 Consultazione della temperatura per ciascun canale Premere brevemente il tasto CH per passare da un canale all altro Ogni volta che verr premuto questo tasto sar visualizzato il canale successivo che sar attivo per ulteriori comandi La sequenza
11. art a new signal search at any time manually Please however check the following points beforehand 1 whether the sensor is still in place 2 the batteries of the sensor and the display device Please also replace them when a battery tester rates them as still being sufficient Further info on this can be found in the FAQ on www irox com Note If the outdoor temperature drops sharply the output of batteries that have been started is also strongly reduced It is therefore recommended that new batteries are always inserted in the sensor at the beginning of the winter alkaline type or better whether disturbances or shields are to be found in the area of the sender receiver or the distance between the two devices is too great The search processes described above for a lost sensor do not have any influence on any other existing sensors that function without problems 35 5 1 2 MIN MAX memory Bata test a The MIN MAX values are always present on the display below the current measurement value LEFT Minimal lowest temperature MIN RIGHT Maximum highest temperature MAX The logic of the recordings is displayed in Section 2 2 Operating elements Please note Lines appear if no data are available This occurs when a channel is not allocated or the sensor is no longer being received 5 1 3 Comfort Zone The Comfort Zone is only displayed for the thermo hygro measurement of the display device With the outdoor senso
12. borate calculation and recording The MIN MAX values are administered here in blocks of four hours Example You want to be able to read the MIN MAX values of the last 24 28 hours at all times Irrespective of when you look at the display you will always see the extreme values of the last 24 28 hours Older recordings are deleted in the process DAY If you select this option the MIN MAX values are recorded for 24 hours in each case You are free to choose when the recording should begin The start is determined by a MEMORY RESET and after 24 hours the memory is automatically reset and a new recording begins Example You want to be able to read the MIN MAX values of the last 24 hours in each case at 8 p m You therefore carry out a MEMORY RESET at 8 p m With this RESET the clock begins to tick internally and this automatically resets the memory after 24 hours and starts a new recording 4 RADIO THERMOMETER The operation of the radio sensor supplied with the device is easy Open battery compartment Select channel Activate batteries i e remove insulation strip or insert batteries please make sure that the polarity is correct Close battery compartment again please ensure that it is tightly closed Other Irox radio sensors that are compatible with the JKTG 4R 3 channels can be used on the channels 1 2 or 3 HTS12C HTS33 HTS13 HTC13 5 channels can be used on all 5 channels HTS55 JKR 1 HTS13 is included
13. chio Per la pulizia utilizzare un panno morbido inumidito con acqua e un detergente delicato Non utilizzare MAI sostanze volatili come benzolo diluenti detergenti spray e simili Quando non in uso riporre l apparecchio in un luogo asciutto fuori dalla portata dei bambini Quando l apparecchio viene attivata a temperature estremamente basse pu accadere che il display non sia pi leggibile Appena l apparecchio si trova in un ambiente pi caldo riprender a funzionare correttamente Conservare accuratamente le istruzioni per l uso e l ulteriore documentazione contenuta nella confezione per poterla consultare anche successivamente Utilizzare esclusivamente batterie nuove e non mescolare mai batterie vecchie e nuove Le batterie esauste non vanno MAI gettate nei rifiuti domestici ma devono essere smaltite negli appositi centri di raccolta IMPORTANTE per gli apparecchi Irox tutte le imposte di smaltimento sui rifiuti in Svizzera TRA e nell Unione Europea WEEE sono gi corrisposte 51 Avviare il procedimento di ricerca per un sensore Selezionare con il tasto CHANNEL il radiocanale desiderato Esempio Canale 4 lampeggia il numero 4 oy CHY Tenere premuto adesso il tasto SEARCH finch il simbolo a forma di onda inizia a lampeggiare Adesso l apparecchio cerca il sensore sul canale n 4 Questo procedimento pu durare qualche minuto e viene concluso non appena il simbolo a forma di onda smette di lamp
14. complessi calcoli interni e relativa memorizzazione valori MIN MAX vengono gestiti in blocchi di 4 ore Esempio per consultare sempre i valori MIN MAX delle ultime 24 28 ore indipendentemente dal momento in cui si consulta l indicatore In tal modo saranno indicati sempre i valori estremi delle ultime 24 28 ore mentre i rilevamenti precedenti saranno eliminati DAY Selezionando questa opzione vengono registrati i valori MIN MAX su un arco di tempo di 24 ore possibile decidere liberamente in che momento iniziare la registrazione L inizio pu essere stabilito da un MEMORY RESET e alla scadenza delle 24 ore la memoria sar azzerata automaticamente al fine di avviare una nuova registrazione Esempio per consultare i valori MIN MAX delle ultime 24 ore ogni giorno alle ore 20 00 effettuare un MEMORY RESET alle ore 20 00 In seguito al RESET parte un timer interno che azzera automaticamente la memoria dopo 24 ore e inizia una nuova registrazione KSPO 1101 10 IROX OST14 MANUAL 4 Ita SIZE W100 x H100 mm BY Lai HZ 23 7 10 IROX JKTG 4R Istruzioni per l uso Version 1 1 1 INTRODUZIONE Meteocentrale ch il portale internet da Meteomedia SA Meteomedia uno dei principali fornitori di servizi meteo d Europa e grazie alle proprie centrali meteo in Svizzera e in Germania specialista tra l altro della moderna previsione di maltempo e intemperie La punta di diamante dell impresa la fitta rete di stazioni meteo p
15. eggiare Abbiamo apposta reso il processo di ricerca richiamabile singolarmente su ogni canale per non influenzare i sensori gi collegati in caso di ulteriori implementazioni Interruzioni di segnale Ogni sensore viene letto dall apparecchio una volta al minuto Se si susseguono pi di 8 letture senza dati appare nel display una barra per il relativo canale e l YKTG 4R interrompe per 8 ore qualsiasi altri tentativi di ricezione Il dispositivo di visualizzazione riparte nuovamente dopo 8 ore con la ricezione Se il trasmettitore originale non viene pi trovato l apparecchio inizia con una nuova ricerca di un nuovo sensore sull attuale canale In occasione dell interruzione del segnale possibile iniziare in qualsiasi momento una nuova ricerca manuale del segnale Verificare prima i seguenti punti 1 Se il sensore ancora sul posto 2 Le batterie del sensore e il dispositivo di visualizzazione Sostituire le batterie anche se un tester le considera ancora sufficientemente cariche Per altre informazioni consultare il sito www irox com nella sezione FAQ Attenzione Se la temperatura esterna cala notevolmente anche le prestazioni delle batterie in uso verr considerevolmente ridotta Si raccomanda dunque di inserire delle nuove batterie nel sensore all inizio dell inverno di tipo alcalino o migliore Se ci sono interferenze o schermatura nell area del trasmettitore ricevitore o se la distanza fra entrambi i dispositivi
16. hether a radio sensor is available in the system or not Please note The M measurement is always depicted in the lower window channels 1 5 one after the other in the upper window 6 CHANGE OF BATTERY 4 BATTERY CHANGE DISPLAY The batteries last for around 8 12 months Depending on the usage of the appliance and the batteries used this time can be slightly shorter or longer In order to avoid a surprising and unpleasant interruption to operations the battery symbol appears in the two temperature windows with the corresponding channel This means that batteries of the display appliance in the IN window or of a radio sender in the CHx window are becoming too weak and need to be replaced To change the batteries please note Chapter 3 Putting into operation Please only use new batteries and never mix old and new batteries Please also remember that used batteries should not be thrown in the household rubbish bin but handed in at the designated collection points The environment will thank you for it 7 CARE INSTRUCTIONS Do not expose the device to extreme temperatures or direct sunlight over longer periods Avoid blows and shocks of any kind to the device For cleaning use a dry soft cloth that you have moistened with water and a mild cleaning agent Never use volatile substances such as benzene thinner cleansing agents in spray cans etc When the device is not being used store it in a dry area and out of the reach
17. in the scope of delivery of the JKTG 4R and can be used on the channels 1 3 With the sensors with thermo and hygrometer simply only the temperature is displayed on the JKTG 4R Reception status display The wave symbol indicates the status of the signal reception of the channel displayed The unit is in searching mode Temperature readings are securely registered No signals Start search process for a sensor Select the desired radio channel with the CHANNEL key Example Channel 4 the number 4 is flashing A CHY Now press and hold the SEARCH key until the wave symbol starts to flash The device now searches for the sensor on channel no 4 This process can take a few minutes and is finished as soon as the wave symbol stops flashing We have deliberately ensured that the search channel can be individually called up per channel so that sensors that are already logged in are not affected by subsequent enhancements Signal interruptions Each sensor is read by the device once a minute If more than 8 readings are read one after the other without data lines appear in the display for this channel and the JKTG 4R then stops any other reception attempts after this for 8 hours The display device starts a reception again by itself after approx 8 hours If the original sender is not found again the device starts with a new search for a new sensor on this channel When the signal is interrupted you can st
18. io valori minimi massimi memorizzati per il canale selezionato stato della batteria del trasmettitore visualizzato Fascia comfort indicazione della fascia comfort per la misurazione del termoigrometro interno Termoigrometro interno IM temperatura e umidit atmosferica relativa all indicatore principale misurazione nel punto in cui si trova l apparecchio valori minimi massimi memorizzati per il termoigrometro interno stato della batteria dell indicatore principale T H SET Per la misurazione interna IN sotto il valore attuale vengono visualizzati i valori MIN MAX di temperatura e umidit atmosferica relativa Questo tasto consente di visualizzare i dati presenti nella memoria del termometro e dell igrometro MIN MAX Questa impostazione permette di gestire e registrare i dati MIN MAX in memoria Questa impostazione unica per tutti i 6 canali Pos 1 PERM Vengono registrati i valori MIN MAX dall ultimo MEMORY RESET mediante la funzione indicazione MAX MIN La registrazione PERMANENTE implica che la registrazione inizia solamente dopo un MEMORY RESET 24 Hr Selezionando questa opzione vengono registrati i valori MIN MAX delle ultime 24 28 ore Al termine di questo periodo di tempo i valori MIN MAX precedenti alle 24 28 ore vengono rimossi dalla memoria Dopo aver selezionato questa opzione si consiglia di iniziare la registrazione in memoria con un MEMORY RESET La nuova registrazione comincia dunque con
19. l apparecchio possibile scaricare gratuitamente in ogni momento le ultime istruzioni aggiornate dal sito www irox com Numero della versione sulla pagina 1 Irox Development Technology 9 DATI TECNICI Misurazione della temperatura e dell umidit Intervallo di misurazione temper Massimo intervallo 50 0 C a 70 0 C 23 0 F a 122 0 F Sensor interno 20 C a 50 C Intervallo di misurazione umidit Massimo intervallo 1 a 99 um rel Sensibilit 0 1 C 0 2 F 1 um rel Precisione di misurazione 1 C in in un intervallo da 5 C a 40 C 2 C in tutti gli altri intervalli 5 um rel in um intervallo da 30 80 da 5 C a 40 C 7 um rel in un intervallo da 20 90 da 5 C a 40 C Frequenza di misurazione del radiosensore una volta ogni 60 secondi Alimentazione 2 pile AM 4 o AAA 1 5V Dimensioni Peso Dispositivo di visualizzazione 86g con pile 69 x107 x10 mm senza piedistallo
20. of small children If the device is activated under extreme coldness it may occur that the display becomes illegible As soon as it is returned to a warm environment the device will function normally Please keep the user s manual and other documents delivered with the device stored carefully so that you can reference them at a later point if necessary Please use only new batteries and never mix old and new batteries Please also remember that old batteries should not be disposed of with household waste but should be handed in at the designated collection centres Important With all Irox appliances all disposal fees in Switzerland vRG advance recycling fee and in the EU WEEE have been paid ENG 8 SUPPORT This device is a new development of Irox Development Technology All information was made and checked by means of a functioning instrument It may occur that adjustments and improvements of the device will take place that due to typographical procedures were not able to be listed in this manual Should you notice deviations which make it difficult for you to operate and use the instrument you may at any time download the latest manual onto your PC free of charge at www irox com please refer to the version number of the manual Irox Development Technology 9 TECHNICAL DATA DISPLAY UNIT Temperature and rel humidity measurement Measurement range temperature Maximum range 50 0 C to 70 0 C 23 0 F to 122 0
21. roprie che si afferma come una delle principali in Europa Irox leader di mercato nella produzione di strumenti di produzione in collaborazione con Meteomedia ha sviluppato una linea di prodotti che si distingue per l elevata qualita delle misurazioni per la semplicit d utilizzo e l elegante design Il modello JKTG 4R un termoigrometro di elevata qualit l unico che offre tre diverse funzioni di memoria per valori massimi minimi La registrazione avviene indipendentemente per ciascuno dei 6 canali presenti Inoltre lo scanning individuale dei 5 sensori radio rende l utilizzo dell apparecchio chiaro e schematico Si prega di leggere attentamente le seguenti istruzioni per l uso contenenti alcune indicazioni utili ed interessanti oltre alle consuete spiegazioni per l uso 2 2 ELEMENTI DI COMANDO TASTI INTERRUTTORI VANO BATTERIE Retro dell apparecchio fo OF le al MEMORY RESET 000000 wwn0 0 0 000 PRODUCT CODE JKTG 4R REF IR8 1062 20 www irox com CF Per impostare l unit di misura della temperatura su C o F MEMORY RESET Tenendo premuto questo tasto per 3 secondi possibile azzerare tutti i dati in memoria IN e CH1 CH5 A seconda dell impostazione dell interruttore MIN MAX avr inizio la nuova registrazione CH CHANNEL CANALE Premere brevemente per passare alla visualizzazione del canale successivo 1 gt 2 gt 3 gt 4 gt 5
22. rs only the temperature is received and displayed it is thus not possible to calculate the Comfort Zone for CH1 CH5 The logic is depicted in the following illustration gt 99 rel humidity Signal collisions Radio signals of other devices in their environment can cause disruptions or temporary interruptions in reception This is not bad but could be annoying under certain circumstances Such typical disruptive systems are radio door bells wireless security systems tube screens PC TV control systems etc In such cases it can also be helpful to use another channel 5 OPERATION 5 1 THERMO HYGROMETER The JKTG 4R measures the temperature and relative air humidity directly and also receives the measurements of up to a maximum of 5 IROX radio temperature sensors Each sensor is to be set to one of the channels 1 5 resp 1 3 for 3 channel devices The temperature currently measured is displayed in the information windows in C or F and for the location of the display device the relative air humidity in and the Comfort Zone The following operations can be made in this function 5 1 1 Reading of the temperature from each channel Briefly confirm the key CH to jump from channel to channel The next channel is thus displayed with each press of the key and activated for further operations The sequence of the activation is CH1 gt CH2 gt CH3 gt CH4 gt CH5 gt CH1 gt etc This is independent of w

Download Pdf Manuals

image

Related Search

Related Contents

Descargue  SMS User Manual - Approved Business  Netgear CA 95054 User's Manual  user manual  Installation  "取扱説明書"  Multiquip QP4TZ User's Manual  guide chauffage bois  MANUALE DI ISTRUZIONI PER L`USO E LA MANUTENZIONE USE  PCS250 GPRS/GSM Communicator Module  

Copyright © All rights reserved.
Failed to retrieve file