1. System Information Mirror Configuration Port Management Port Config r Mirror Config Mirror Port 1 fvl Rate Limit SE g T S Pl GE Al 2 3 4 5 Storm Control Statistics Mirrored Port Function Setting 6 7 8 9 10 VLAN Setting i n MAC Address Setting i RSTP Setting 1 Port mirroring is implemented by copying and forwarding the frames of one or more monitored ports to the monitoring port which greatly IGMP Snooping helps police in monitoring Internet access by Internet caf s or enterprises 802 1X Setting 2 The bandwidth of the monitoring port should equal or exceed that of the monitored part s 3 The monitoring part and the monitored port can not be the same Syste Sy SE 4 Cross VLAN port monitoring is supported kobla 5 The monitoring port can no longer transmit data but only connect to a monitoring server or analyzer http 192 168 0 1 mirror submit Refresh Internet Note 1 The bandwidth of the monitoring port should equal or exceed the total bandwidth of the monitored port s 2 Monitoring mirror port is usually connected to a terminal only It can not be connected to other devices such as another switch 3 If the monitoring port is just the monitored port system automatically ignores the monitored port 3 3 3 Rate Limit To enter Rate Limit interface as shown below click Port Management Rate Limit
2. Group Pan 1 2 3 4 5 6 7 8 9 10 Normal d ll al i i Group 1 elelelelelielelielele Se Lo Es Lo Trunk Arithmetic Choice OO Sne MAC Address O Destination MAC Address 7 Source and Destination MAC Address 1 Trunk which is usually called port aggregation is mainly used to expand the bandwidth and hot backup error toler channel ance of inter switch uplink 2 Once a port is set as a member of a Trunk group it can not be used for other purposes except for this Trunk group whether it is being used by this Trunk or not 3 Atrunk group is allowed to include a maximum of 4 member ports and a minimum of 2 ports Please set 4 Cross VLAN Trunk is not supported that is all Trunk group members must be on the same VLAN othe 5 When Trunk group is used in inter switch uplink make sure the uplink ports of link switch are in the same Trunk http 192 168 0 1 aggr submit Refresh rect Tru ly nk function will fail Internet The switch supports a maximum of 3 trunk groups To configure a trunk group select some ports to add to the corresponding group 1 2 3 and a trunk arithmetic choice then click the Apply button Fields on the above page are described as below Field Description S Normal A port that does not join a trunk group is regarded as a normal port By default all ports are normal ports Group Selec
3. Qos UI System Information rd Port Management Function Setting Port ID Port Priority 802 1P tag Priority 802 1P Default Priority DSCP Priority EDER 1 jl low v Disable Owl Disable v Trunk Config QoS Config SNMP Config R Note VAN Setting 1 QoS function can be implemented through the combination of configuring priority mode and priority control operation This switch supports 4 MAC Address Setting priority levels of high medium normal and low for packet mapping eem 2 If 802 1Q VLAN Tag priority is enabled the switch will automatically read the 3 bit Priority tags in packets with VLAN Tag Priority of 0 or 1 is g mapped into low priority queue priority of 2 or 3 is mapped into normal priority queue priority of 4 or 5 is mapped into medium priority queue IGMP Snooping and 6 or 7 into high priority queue 802 1x 3 If DSCP priority is enabled the switch will automatically read the 6 bit DSCP Priority tags in packets with IP header Priority of 0 is mapped into low priority queue priority of 10 or 18 is mapped into normal priority queue priority of 26 or 34 is mapped into medium priority queue and System Setting 46 into high priority queue Find more productes of 4 When multiple priority modes are enabled only one mapped priority takes effect in the order of DSCP priority gt tag priority gt port priority For TENDA gt gt gt example when the three priority modes are simultaneously enabled on port 1 then
4. Apply No Limit Unknown Unicast Rate No Limit gt VLAN Setting MAC Address Setting _RSTP Setting IGMP Snooping 802 1X Setting System Setting Find more productes of ENDA gt gt gt http 1192 168 0 1 stormetrl submit Refresh Internet This page displays the storm control status of broadcast multicast and unknown unicast 19 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide rates No limit means not controlled You can configure a specific storm rate just remember to click the Apply button to activate your setting When a corresponding traffic exceeds the configured value system will drop some excessive frames to reduce the traffic into a reasonable range thus effectively controlling various storms avoiding network congestion and ensuring normal processing of traffic Fields on this page are described as below Broadcast Rate The permitted rate for broadcast packets to pass through the switch Multicast Rate The permitted rate for multicast packets to pass through the switch Unknown The permitted rate for unknown unicast packets to pass through Unicast Rate the switch 3 3 5 Statistics To enter port statistics interface click Port Management Statistics as shown below a Ei TERDA TO Port Gigabit Intelligent Dok Switch Microsoft Internet Explorer le Edit Vie Favorites Tools Help System Inf
5. Displays and allows you to configure mirror Mirror Config port mirroring source port and mirrored port mirroring destination port oi Dien d all f isplays and allows you to configure Management Rate Limit ES y g Ingress Egress packet RX TX rate on a port Displays and allows you to configure the rate Storm Control of broadcast multicast and unknown unicast frames passing through every port Displays RX TX packet counts TX RX byte Statistics counts and RX TX error packet counts Displays and allows you to configure the power management mode and status of power PoE Config utilization and PSE temperature this feature is disabled on all ports by default G Displays and allows you to configure member PE Trunk Config ports for a port aggregation group and Trunk Setting algorithm Displays and allows you to configure QoS QoS Config modes of port based 802 1P and DSCP Allows to configure SNMP server address and SNMP Config community name VLAN Setting VLAN Mode Allows you to select port based VLAN or 802 1Q VLAN Displays and allows you to configure port Port VLAN ieee Meed based VLAN groups and its member ports ER Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide LI Displays and allows you to configure 802 1Q 802 1Q VLAN VLAN groups and its member ports Allows you to configure PVID ingress filter Tag VLAN Config and port Tag Allows you to enable MAC address aging and MAC Aging oo configure agi
6. transmission of multicast packets but also the transmission of IGMP control packets for establishing multicast groups is confined to the VLAN If a certain VLAN is deleted then all multicast groups previously created upon it will be deleted as well 3 IGMP Snooping on Triple Standard IGMP Packets IGMP Query Packets These packets are sent by routers and consists of general query and specific group query packets IGMP Report Packets These packets are sent by hosts and generated when a host actively wants to join a certain multicast group or responds to a router s query The switch TEG1210P supports IGMP v1 IGMP v2 and IGMP v3 Report packets IGMP Leave Packets Hosts running IGMP v1 will not send IGMP Leave packets when leaving a multicast group While hosts running IGMP v2 or IGMP v3 will send IGMP 51 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Leave packets to inform the multicast router that they have left a certain multicast group gt 802 1x As an authentication protocol 802 1X provides methods and policies for authenticating users It is a port based authentication policy that requires 802 1x supported switches and PCs to use EAPOL 802 1x EAPOL is a layer 2 protocol If a switch s ports are configured with 802 1x then these ports will first be in unauthenticated state when devices are detected on them At this time users PCs can only use EAPOL to communicate with the switch They need to
7. 168 0 1 mac_filter submit Refresh Internet 2 To delete an added MAC address click the corresponding Delete button in the delete column If the Delete All button is clicked all MAC addresses in the table will be deleted 32 TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Tenda 3 6 3 Static MAC According to the actual conditions network administrators can manually add or delete the static MAC addresses in static MAC table to reduce broadcast traffic in a network This switch supports a maximum of 64 static MAC address entries To enter the page below click MAC Address Setting Static MAC ATENDA TO Port Gigabit Intelligent POE Sch Microsoft Internet Explorer Ele Edt wiew Favorites Tools Help Q x 2 CD Ps Jervie O R 3 D Address E http 192 168 0 1 login B Fenda 802 1X Setting System Information Static MAC Address Port Management Function Setting VLAN Setting MAC Address 00 BO 4c 00 00 10 MAC Address Setting Port ID 1 MAC Aging Add Address MAC Filter Static MAC 1 To allow some network devices to be fixedly connected to the switch and keep their MAC addresses un refreshed you can add them to the static address table RSTP Setting 2 Ifyou want a network device to connect to the switch via a specific port only you can just add its MAC address to the static address table and IGMP Snoopi
8. http 192 168 0 1 dot1x submit Refresh Internet This page allows you to configure 802 1x port authentication status Fields on the above page are described as below Field besemption S Switch s Port ID number Admin State Force Authorized Force Unauthorized Auto Force After it is clicked the corresponding port will perform forced Re authenticate re authentication Description of the three authentication modes Force Authorized port remains authorized and switch authentication end does not actively initiate authentication Force Unauthorized the port remains unauthorized and ignores authentication initiated 40 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide by all clients Auto The port uses 802 1X to communicate with the clients and switch between authentication and un authentication states 3 10 System Setting 3 10 1 Change Password To enter the page below click System Setting Change Password DATO Por Gigabit Intelligent Dok Switch Microsoft Internet Explorer dit View Favorites Tools Hel File Edit Vi an I Help Gen x 2 G search She Favorites 2 LK a 3 System Information i Change Password Port Management Function Setting Configuration Content VLAN Setting Old P MAC Address Setting New Password length 15 _ RSTP Setting Confirm New Password IGMP Snooping 802 1X Setting Apply
9. Gateway Gateway IP address 0 0 0 0 by default MAC Address The switch s physical address ARL Aging Time Switch s aging time of the MAC address 300 s by default 3 3 Port Management 3 3 1 Port Config To enter the interface below click Port Management Port Config as shown below TENDA 10 Port Gigabit Intelligent POE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help Osch AG JO search se Favorites 4 9 ke Wl G3 Address http 192 168 0 1 login v Go Links Gr System Information Port Configuration Fl Port Management Port Config Mirror Config Port Admin Auto Negotiate Speed Duplex Flow Control Rate Limit 1 Enable w Enable w Enable m Storm Control Statistics Apply _ Function Setting _ VLAN Settin 0 Port Status MAC Address Setting _RSTP Setting Link Speed Flow Link Flow Port Sj d Mod Port Sj I Mod Sj d Dun IGMP Snooping Status ele Duplex Control Status pest der Peers Control HAR 1 Down Auto Negotiate Down Enable 2 Linking Auto Negotiate 100Mbps Full Enable System Settin ues 3 Down Auto Negotiate Down Enable 4 Down Auto Negotiate Down Enable Find more productes of I t l ee 5 Down Auto Negotiate Down Enable 6 Down Auto Negotiate Down Enable 7 Down Auto Negotiate Down Enable 8 Down Auto Negotiate Down Enable 9 Down Auto Negotiate Down Enable 10 Dow
10. Hardware Installation Description rrronrrnnnnnnrnnnrvrnnernnnnnnnnnnnrnnnrnrnnennanernnsnennnnne 8 2 3 SWIICN S Front Panel scien ssdexiivnndinisansisincenabatendsviniiniesdiuadvelkedudbeueiuwaunctvanvsebidncetiuasent 9 2 4 Switch s Back Panel rrnnnrrnnnnnrvvnrnnrrnnnnnnrrnnnnerennnnerernrnnerennnnnnrennnsnsrnnnnreennnereennn 10 CHAPTER 3 CONFIGURATION GUIDE 2 ene geeek ee egeukusgeeesegeuEkEebeEEeKUEeEeeEdeh ENEE anode 11 TEN 11 3 1 1 Configuration Requirements rrrrrvnnnnrrvvrnnrrrrrrnnerernrnrrernnnrrrnnnnsrrennnnereennn 11 3 1 2 Configuration Preparation cccccceeeeceeseeeeeeaeeeeeeeeeeeeeeeeeeeeeeaeeeeesaeeeeeeaes 11 3 1 3 Configuration Interface Description rrrrrnnrrrrrrnnrrvrrnnrrenrrnnrrrrnnrrernnnrrennnn 12 3 2 System INoMm lon ur ccaviManesainwiniacvealusvisatalesusnadaiabehiasivediaeaidncinutnieeceaanus 15 3 3 Port Management 16 3 3 1 Port ln Le E 16 3 3 2 Mirror Config EN EE 17 HE hehe EENEG 18 3 3 4 Storm Een de EE 19 3 3 5 Statistics ais dain houses da winsindy an st tindea baltdetuaiudu vans bisienicemon dream Scusiedeniilud dihovwanenowiedeaiude 20 34 Function Setinguuuauussmimmmieseuibse Vevesduvinnstuecdhenndeckerts ied lt ivien dnciaddernatiwendivens 21 341 POE JG 21 3 4 2 Trunk Config ET 24 3 4 3 QOS Config ED 25 3 4 4 SNMP Config rerrnnnrnvvnnnnvvvvnnnnvnrrnnervnnnnerennnnnsrennnensenvnnnsnennnneseennnnsen
11. PoE Switch User Guide ATENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help a Qa x A CD Preach erves OG Ar amp LR 3 Address http 192 168 0 1flogin Bo us amp Fenda Port Management Function Setting _ VLAN Setting Backup Config _ MAC Address Setting Press Download and then select the path of the configuration file RSTP Setting Download IGMP Snooping 802 1X Setting System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout Find more productes of TENDA gt gt gt http 1192 168 0 1 cFadownload htm Internet This page allows you to backup switch s current configurations To backup your current settings first click the Download button and then select a path to save the file 3 10 7 Restore To enter the page below click System Setting Restore ATENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer Eile Edit View Favorites Tools Help a Qa x 2 CD Per Jerves OG R amp DAG 3 Address http 192 168 0 1 login Bo m amp Tenda Port Management J o Restore configuration from file Function Setting VLAN Setting MAC Address Setting open the configuration file Browse _ RSTP Settin i IGMP Snooping S
12. Switch in a rack follow instructions below The switch is designed for a standard sized 19 inch rack and can be mounted into an ElA compliant standard rack Attach the 2 included brackets to each side of the switch and fix it with screws and then place it horizontally in a layer of the rack and fix it in the rack with screws as shown in the figure below Attaching L shaped Brackets Fixing the Switch in the Rack 2 3 Switch s Front Panel The switch s front panel includes network ports LEDs and a Reset button as shown below Tenda tec1210P Mi gegegege TT o Switch s Front Panel Network Ports 8 10 100 1000Mbps auto negotiation RJ 45 network ports 2 Gigabit fiber module Mini GBIC ports LEDs 1 SYS status LED and 1 Power status LED 2 8 Link Act port status LEDs 8 SPEED LEDs 8 PoE LEDs 2 SFP LEDs You can see the Switch s operating statuses through the above mentioned LEDs whose 9 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide definitions are described in details in the table below LED Color Status Description Always ON Switch has power Switch has no power please check whether AC OFF power supply is correctly connected to switch or not Er ON Valid link Link Act Green Flashing Data being transmitted OFF No link on ports or incorrect link Always ON 1000Mbps 10 100Mbps or disconnected ams oreen parare ON pS Switch works SE Poe
13. address Subnet mask Defaut gateway Use the folowing DNS server addresses Preferred DNS server Alemate DNS server Advanced Figure 6 7 Click OK to return to the Local Area Connection Properties window 8 Click Close to exit the window 4 3 Appendix 3 Solutions to login failure When coming across switch login failure first make sure whether you can access the switch through ping command or not If switch IP is accessible through ping command then problem might be with your browser We recommend you to change for another PC And if it is not please follow the steps below 1 Check whether the IP addresses of the management PC and switch are within the same net segment 2 Check whether there are problems with the cable connecting PC and switch or whether the cable is too long 3 Check whether switch s corresponding SYS LED is Always ON 4 Try to connect switch to PC through another port 5 Check whether the switch s management VLAN has been changed 6 Check whether the port connecting PC is set to a different PVID with that of the 55 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide management VLAN 7 Check whether the PC s NIC has been set with a specific VID and the port connected has been set with PVID filter 8 Please contact technical support of our branch company at your place for help if the above mentioned can still not s
14. oreen KT CE corresponding port is supplying power OFF The corresponding port is not supplying power Valid link on SFP port OFF No link on SFP port Green Reset Button The Reset button is located under the Power LED on the switch s front panel and can be used to clear current configurations and restore factory default values How to use the Reset button To restore factory defaults press and hold the button for more than 5 seconds when switch functions correctly Switch will automatically restore factory defaults And when the SYS LED re lights up it indicates the switch has been rebooted and applying factory default settings Note Do NOT press this Reset button unless you want to have current configurations deleted 2 4 Switch s Back Panel There is 1 AC POWER outlet and a switch in the back panel as shown in the below figure Switch s Back Panel 10 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Chapter 3 Configuration Guide 3 1 Login 3 1 1 Configuration Requirements With the embedded web server in TEG1210P you can manage and maintain the switch through the web based interface Before accessing switch s web configuration interface make sure your PC meet the following basic configuration requirements gt PC OS windows 98 higher above gt Ethernet NIC installed gt Web browser Internet Explorer 6 0 or Firefox 1 0 higher installed gt TCP IP protocols installed and enab
15. provides 8 10 100 1000Mbps auto negotiation RJ45 ports that support Auto MDI MDIX and implement wire speed forwarding All its RJ45 ports support PSE PoE feature and IEEE 802 3af to auto identify an IEEE 802 3af compliant device and power it via a network cable at the maximum power of 15 4W supported by a single port Besides with the 2 provided independent SFP ports users can flexibly extend their network from 100 meters to over 80 kilometers In addition TEG1210P supports port mirroring port bandwidth control port based tagged VLAN trunk static MAC address table QoS port authentication port traffic statistics and power save mode etc The switch is a user friendly plug and play device without need for configuration It extends family and office network without being restricted by the spatial distribution of cable 1 1 Product Features e Complies with IEEE802 3 IEEE802 3u IEEE802 3ab IEEE802 3z IEEE 802 3af Ethernet standards Provides 8 10 100 1000Mbps auto negotiation RJ45 ports that support Auto MDI MDIX and auto negotiation on duplex mode and transmission rate 8 RJ 45 ports provide PoE PSE function Supports IEEE 802 3af standard and can work as a PSE to automatically power a device via a network cable at the maximum power of 15 4W supported on a single port 2 independent SFP ports Adopts Store amp forward scheme and is integrated with a 8K MAC address table with MAC address learning and auto aging supported Suppor
16. table and IGMP Snooping specify a port 902 1x Note A maximum of 64 static MAC address entries are allowed Syste ii i System Seting Static MAC Address Table Find more productes of TENDA gt gt gt NO Source MAC Port ID Operation 1 00 b0 40 00 00 10 1 Delete All http 192 168 0 1 mac_static submit Refresh Internet 33 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 2 To delete an added MAC address click the corresponding Delete button in the Operation column or the Delete All button 3 7 RSTP Setting 3 7 1 RSTP Config To enter the page below click RSTP Setting RSTP Config TENDA 10 Port Gigabit Intelligent POE Switch Microsoft Internet Explorer Ge Search Ka Favorites O 2 amp K 3 Address http 192 168 Tenda System Information RSTP Configuration Port Management Function Setting System Priority 32768 v _ VLAN Setting MAC Address Setting RSTP Setting RSTP Config Forward Delay 15 RSTP Port RSTP Status fersion RS vw IGMP Snooping Apply 802 1X Setting System Setting Find more productes of TENDA gt gt gt To configure STP function enter parameter values and click the Apply button Fields on the above page are described as below Field Description S System Configure the system priority in STP function the smaller this Priority configured va
17. 0 by default The Period value options available range from 1 to 3600 seconds Configure EAP response timeout 30 seconds by default The EAP Timeout value options available range from 1 to 255 seconds 3 9 2 802 1x Port To enter the page below click the 802 1x Setting 802 1x Port tabs 2 TENDA 10 Port Gigabit Intelligent Por Switch Microsoft Internet Explorer File Edt View Favorites Tools Help a Osch x a amp JO search J Favorites amp 9 ke KR as Address http 192 168 0 1 login v Go Links gt y System Information 802 1X Port Configuration Port Management Function Setting Part Admin State Port State Force Re authenticate VLAN Setting 1 Force Authorized v 802 1X disabled Force Re authenticate LAGEN 2 Force Authorized x 802 1X disabled Force Re authenticate _RSTP Setting ne 3 Force Authorize d v 802 1X disabled Force Re authenticate IGMP Snooping 4 Force Authorized v 802 1X disabled Force Re authenticat 802 1X Setting 8021X 5 Force Authorized x 802 1 disabled Force Re authenticate BESSE 6 Force Authorized v 802 1X disabled Force Re authenticate System Setting ete 7 Force Authorized v 802 1X disabled Force Re authenticate gt gt gt PENE 8 Fi Authorized 802 1X disabled Force Re authenticate 9 Force Authorized v 802 1X disabled Force Re authenticate 10 Force Authorized v 802 1X disabled Force Re authenticate Apply JE
18. A maximum of 64 MAC address entries are allowed MAC Filter Table 802 1X Setting System Setting Find more productes of TENDA gt gt gt NO Source MAC Delete All http 192 168 0 1 mac_filter submit Refresh Internet 1 Steps taken to add MAC address for filter are listed below 1 Enter a MAC address for filter such as 00 B0 4C 00 00 AA in the MAG address box 2 Click the Add Address button to complete the configuration 3 View the MAC filter table It should display the added MAC address as shown below P TENDA 40 Port Gigabit Intelligent Por Switch Microsoft Internet Explorer File Edit View Favorites Tools Help Sp Q x A Ps fervore Zi A 3 JKA 3 Address http 192 168 0 1 login sl ge m e Tenda System Information MAC Filter Port Management Function Setting VLAN Setting MAC Address _ MAC Address Setting MAC Aging MAC address filter function enables you to add the MAC addresses of PCs and other devices to the MAC address filter table so that they are MAC Filter prevented from accessing network through the switch Static MAC Note A maximum of 64 MAC address entries are allowed _ RSTP Setting IGMP Snoopin e Mi MAC Filter Table 802 1X Setting System Setting Find more productes of 3 Source MAC Operation ENDA 1 00 b0 4c 00 00 aa Delete Delete All http 192
19. Notes 802 1X Setting 1 Ittakes about 30 seconds to restore a configuration file Please be cautious about any operations during the restore process to prevent System Setting accidents such as PC or power goes down etc E 2 After the configuration is restored please use the IP configured before backup to lag in to the switch Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout Find more productes of TENDA gt gt gt i E http 1192 168 0 1 cFgupload htm Internet This page allows you to restore previous configuration from backup files To perform this function click the Browse button to select a previous backup file and click the Restore button Note It takes about 30 seconds to restore a configuration file Please be cautious about any operations during the restore process to prevent accidents such as upgrade operation and PC or power goes down etc Reboot the switch after the restore operation finishes 45 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 10 8 Warm Restart To warm restart your switch first click the System Setting Warm Restart tabs to enter the page below TENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help I Qa x A CD Ps Jervie O Ar 5 JKA a Address E http 192 168 0 1 login Fen
20. P STP on a corresponding port by Protocol Enabled default it is disabled on all ports The port that connects a terminal is usually set to an edge port Edge which has a fast state shift There is no need for an edge port to take 2 times of forwarding delay time to shift from blocking state to forwarding state The path cost value is in the range of 0 200000000 and is Path Cost Auto by default when set to 0 it means the port path cost is automatically determined according to the port rate 3 7 3 RSTP Status To enter the page below click RSTP Setting RSTP Status 35 System Information RSTP Bridge Overview Port Management Function Setting Bridge ID Hello Time Max Age Forward Del lay L VLAN Setting MAC Address Settin _RSTP Setting j RSTP Config RSTP Port Status _ RSTP Port RSTP Status IGMP Snooping Edge Port P2P Port 802 1X Setting System Setting Find more productes of TENDA gt gt gt E D a Gi IS Fields in the RSTP Bridge Overview table on the above page are described as below mos desertion O Bridge ID The current Bridge ID a switch is called a bridge in STP The bridge ID which consists of bridge priority plus bridge MAC address is a determinant in selecting Root Bridge in spanning tree initial phase The bridge ID of a root bridge selected in STP namely the bridge with smallest bridge ID which consists of
21. System Setting _ Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout This page allows you to modify switch s login password which is allowed to consist of a maximum of 15 characters To modify a password first enter the valid old password new password and confirm the new password then click the Apply button After you modified the password you have to use the new password for next time login to switch s web based management interface 3 10 2 Power Save The power save mode which is a low carbon technology can be used to save system energy consumption When this feature is enabled the energy consumption of the ports that are not connected to devices is almost zero which greatly reduces the system s energy consumption but might affect the ports driving distance It is recommended not enable the power save function when a port s driving distance exceeds 80m It is disabled by default 41 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide To enter the page below click System Setting Power Save A TENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help a Gea x A search ferries O A Lh 3 Address http 192 168 0 1 login vel Be uns G Tenda System Information Power Save Mode Port Management T _ Function Set
22. Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Copyright Statement Tenda is the registered trademark of Shenzhen Tenda Technology Co Ltd All the products and product names mentioned herein are the trademarks or registered trademarks of their respective holders Copyright of the whole product as integration including its accessories and software belongs to Shenzhen Tenda Technology Co Ltd Without the permission of Shenzhen Tenda Technology Co Ltd any individual or party is not allowed to copy plagiarize reproduce or translate it into other languages All photos and product specifications mentioned in this manual are for references only Upgrades of software and hardware may occur and if there are changes Tenda is not responsible for notifying in advance If you would like to know more about our product information please visit our website at www tenda cn Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Table of Contents COPYRIGHT STATEMEN Fun en 1 TABLE OF CONTEN T eege 2 PREFACE E 4 About this user manual 4 Security E It in e E 4 CHAPTER 1 PRODUCT INTRODUCTION we vssisccnssnscccscssetecsisnssssnsnccctanseecsssasteenvensenanencas 5 1 1 Product GE 5 1 2 Technical Gpoecihcaton cesses eesseseeseeeeeseeeesaeeeeaeeesseeees 6 CHAPTER 2 HARDWARE INSTALLATION nnnunnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnenennnnnnnnnnvnnnnnnnennr 8 2 1 Package Contents AANEREN 8 2 2
23. Windows Firewall settings or pick a Control Panel icon Internet Options Network Connections A Network Setup Wizard 7 Windows Firewall Wireless Network Setup Wizard Figure 2 3 Click Network Connections to display the following window File Edit View Favorites Tools Advanced Help Osch X s 3 SE 15 Folders fe Address Network Connections LAN oF High Speed Internet Network Tasks Create a new connection canniected i Set up a home or small tl Realtek RTL8139 Family PCF office network Change Windows Firewall settings See Also i Network Troubleshooter Other Places D Control Panel Kl My Network Places VH My Documents d My Computer Details Network Connections System Folder Figure 3 4 Right click Local Area Connection and select Properties 53 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Network Connections BAX Fie Edit View Favorites Tools Advanced Help r CO Back v gt 3 gt Search Er Folders E Address e Network Connections x Go Al LAN or High Speed Internet EEr o 7 Local Area Connection E Create anew 5 Con d connection a Realt one rs ed kal Set up home or small a Disable office network Status Change Windows Repair Firewall settings Disable this network Bridge Connections device Ki Repair this connection Create Shortcut mj Rename this connection Rename view status of this
24. agement of power supply high security 2 Easy connection PD terminal does not need an external power supply can be used with the original network s cable distribution unchanged 3 Standard 802 3af compliant globally unified PI power interface 4 Far flung application prospect available for use in IP telephone wireless AP Access Point portable charger and network camera etc gt A PoE system consists of PSE PD and PI 1 PSE Power Sourcing Equipment It consists of power supply and PSE function module and can implement the functions of detecting PD obtaining PD power information remote power delivery monitoring power delivery and cutting power supply 2 PD Powered Device It can be classified into two types standard PD and 21 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide non standard PD the former refers to an 802 3af compliant PD Common PDs include IP telephone wireless AP and network camera 3 PI Power Interface It refers to the port that connects a PSE PD via a network cable namely RJ 45 port 2 PoE port configuration To enter the page below click Function Setting PoE Config ATENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer Ele Edt View Favorites Tools Help r Osch MAG J search she Favorites s H Wl as Address http 192 168 0 1 login
25. be installed with an application program that supports 802 1x such as Windows that supports 802 1x so the ports will start forwarding data traffic as soon as users pass the authentication The switch s ports return to unauthenticated state upon user s logout or when there is no traffic after a long time elapses the authentication will be ended due to timeout In this case the user is required of re authentication 4 2 Appendix 2 How to Set TCP IP Windows XP is used as an example This chapter instructs you how to configure TCP IP protocol under Windows XP The procedures are outlined as below 1 Click Start Control Panel to enter the control panel Figure 1 52 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 2 Click Network and Internet Connections to enter the connection page File Edit View Favorites Tools Help Qa O P sen gt Faders E Address J Network and Internet Connections y Network and Internet Connections See Also My Network Places Printers and Other H Fi Pick a task JE Remote Desktop b Phone and Modem Options gt Set up or change your Internet connection Create a connection to the network at your workplace Troubleshooters D gt Set up or change your home or small office network Home or Small Office Networking A Internet Explorer Network Diagnostics EI Set up a wireless network for a home or small office 3 Change
26. ccordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna lIncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 57 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 4 6 Appendix 6 Technical Support If you have any poblem please contact our customer service or technical support Technical Support Toll Free 400 6622 666 For mainland China only Toll Free 1 800 570 5892 For USA only Tel 86 755 2344 2820 Skype tendasz MSN tendasz hotmail com Email support tenda com cn Headquarter Shenzhen Add Tenda Industrial Zone No 34 1 Shilong Road Shiyan Town Baoan District Shenzhen China Zip code 518108 Tel 86 755 27657180 Fax 86 755 27657178 Email sales tenda com cn Technical Support support tenda com cn Or visit our website at http www tenda cn 58
27. configuration Allows you to configure priority for switch s physical port the Port Priority switch prioritizes the packets received transmitted by the port with high priority according to different port priority levels Which are low normal medium and high After this feature is enabled switch automatically reads the 3 bit priority tags in packets with VLAN Tag Priority of 0 or 1 is 802 1P mapped into low priority queue priority of 2 or 3 is mapped into tag Priority normal priority queue priority of 4 or 5 is mapped into medium priority queue and 6 or 7 into high priority queue By default this feature is disabled 802 1P This feature takes effect after 802 1P tag priority mode is Default Priority enabled For frames without tags switch will use the configured default value here to replace their priority fields After this feature is enabled switch automatically reads the 8 bit DSCP Priority tags in IP packets and automatically maps the first 3 bits into the 4 preconfigured priority queues By default this feature is disabled 3 4 4 SNMP Config SNMP is a technology that enables network administrators to manage network easily discover and solve network problems timely as well as plan the future of network increment This switch is compatible with SNMP v1 SNMP v2c and supports the following MIB Database of Management Interface RFC1213 MIB IN gt RFC2863 IfMIB gt RFC2819 Rmon Statistics MIB gt RFC4788 Bridg
28. connection Properties Change settings of this connection Other Places a D Control Panel SJ My Network Places My Documents d My Computer Details a Figure 4 5 Select Internet Protocol TCP IP on the appearing window and click Properties button Local Area Connection Properties General Authentication Advanced Connect using E9 Realtek RTL8139 Family PCI Fast Ett This connection uses the following items Client for Microsoft Networks A File and Printer Sharing for Microsoft Networks 005 Packet Scheduler 4 A S 4 se Lienen De ford X Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected C Notify me when this connection has limited or no connectivity Figure 5 6 Select Use the following IP address and enter the IP address 192 168 0 xxx xxx can be any value from 2 254 and subnet mask 255 255 255 0 54 TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports thes capability Otherwise you need to ask your network adminestrator for the appropnate IP setbngs Obtan an IP address automaticaly Use the following IP address IP
29. da Port Management E Warm Restart Function Setting VLAN Setting MAC Address Setting RSTP Setting IGMP Snooping 802 1X Setting _ System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Please press the Restart button to reboot the switch Logout Find more productes of TENDA gt gt gt http 192 168 0 1 jwreset htm Internet Then click the Restart button on the above page to reboot the switch During this process the switch will be disconnected temporarily and then re connected quickly The login interface will appear after the reboot 3 10 9 Logout To log out from the switch s web based management interface safely click System Setting Logout tabs and click the OK button in the Are you sure to logout dialogue box then the Yes button when system prompts to close the window Ki KS Microsoft Internet Explorer YD re vou sure bo logout Microsoft Internet Explorer 9 The Web page you are viewing is trying to close the window ve Do you want to close this window E 46 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Chapter 4 Appendixes 4 1 Appendix 1 Glossary gt QoS 1 Overview of QoS QoS Quality of service is the ability to provide better priority including improvement on a required bit ra
30. dopts poll scheme and provides basic functions thus specially adapting to the application in small sized fast and low cost network environment It is implemented based on unconnected transport layer protocol UDP thus enabling access to multiple devices without difficulties 48 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 2 SNMP Working Scheme SNMP consists of NMS and Agent NMS Network Management Station is a workstation that runs client programs Agent is the server software that is run in network devices such as a switch NMS sends GetRequest GetNextRequest and SetRequest frames to Agent and the agent upon receiving the frames according to frame types performs Read or Write operation on MIB and generates and returns Response frames to NMS 3 Versions of SNMP This switch is compatible witn SNMP v1 and SNMP v2c and uses community name for authentication thus a SNMP frame with the community name that is not recognized by the switch will be discarded The community name defines the relationship between SNMP NMS and SNMP Agent It functions equivalently as a password that can restrict SNMP NMS from accessing SNMP Agent in a switch 4 Trap Trap is the message that is actively sent by a managed device to NMS to report some important and urgent events such as the managed device is rebooted etc gt VLAN 1 Overview of VLAN VLAN virtual local network can be used to logically instead of physicall
31. ductes of TENDA gt gt gt IGMP Configuration List http 192 168 0 1 figmpconf submit Refresh Internet Check the box to enable IGMP snooping function and check a port number to be a routing port then click the Apply button to finish your settings Fields on the above page are described as below Field Description o O IGMP Enable Check to enable this feature or uncheck to disable it The port of a switch that receives IGMP packets from multicast Router Ports i routers IGMP Per VLAN based configuration of IGMP snooping enabled and Configuration List IGMP querying enabled Note only after the overall IGMP Snooping function is enabled can it take effect Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 8 2 Snooping Status To enter the page below click IGMP Snooping Snooping Status I TENDA 10 Port Gigabit Intelligent Por Switch Microsoft Internet Explorer File Edit View ites Tools Help View Favorites T He Osch MAG gt search sie Favorites EC ds ke RK as Address hetp 192 168 0 1 login v Go Links Gr System Information IGMP Status List Port Management _ Function Setting S VLAN Queri Queries Queries 1 v2 v3 v2 VLAN Setting ID Ee transmitted received Rep Report Report Leave MAC Address Setting 1 Idle o o o o o o _ RSTP Setting Refres h IGMP Snooping Snooping Conf
32. e MIB 26 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide To enter the page below click Function Setting SNMP Config TENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Hel File Edit yi Favor I Help Osch x A GA sam Jeras R do JKA a Address 7 http 192 168 0 1 login v Go Links Gr System Information SNMP Configuration Port Management Function Setting PoE Config SNMP enabled Enable S Trunk Config SNMP Trap destination 0 0 0 0 QoS Config SNMP Config SNMP Read Community HUN SNMP Write Communi ity private MAC Address Setting SNMP Trap Commu _RSTP Setting IGMP Snooping 802 1X Setting public public To configure the parameters on the above page just enter values you want to configure and then click the Apply button to finish Fields on the above page are described as below Field Deserption SNMP Enabled Check the box to enable SNMP management function SNMP The destination IP address to which switch s trap information is Trap Destination going to send Configure the read only community name of the SNMP SNMP information of the switch To read the SNMP information of the Read Community switch SNMP management software must contain the same read only community name Configure the writable community name of the SNMP SNMP information of the switch To
33. ent Function Setting VLAN Setting DHCP Client Enable MAC Address Setting IP Address 192 en Up 1 IG Subnet mask 255 255 255 l o IGMP Snooping g t 0 o o 0 802 1X Setting Management VLAN 1 System Setting Notes Change Password 1 After you have enabled DHCP client check the IP address assigned by DHCP server and then ect the switch Power Save 2 If DCHP is timed out or fails to address the switch will automatically disable the DHCP function and you have to use the last Upgrade time manually configured IP addr nnection IP Config 3 Management VLAN can be modified only when 802 10 VLAN is enabled Restore Factory Default Backup Apply Restore a Warm Restart Logout a http 192 168 0 1 ipconfig submit Refresh Internet If a new IP address is configured and the Apply button is clicked switch will restart and return to the login interface Field Description o O DHCP Client Disable or enable DHCP client This field allows you to modify the switch s IP address 192 168 0 1 IP Address by default You can use the currently configured IP address to log in to the switch s web based management page to manage the device Allows you to modify switch s subnet mask 255 255 255 0 by Subnet Mask default 0 0 0 0 by default changeable Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Note If you have enabled DHCP client check the IP address assigned by DHCP
34. exceeds 120W then the termination of power allocation is determined according to port priority Each port provides high medium and low 3 priority levels System prioritizes power distribution to the port with high priority level By default all ports are in low priority level and ports with smaller port numbers have higher priority levels Static This feature takes effect in static allocation mode You can Allocation W configure specifically distributed power for the ports A max power of 15 4 W is permitted per port 23 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 4 2 Trunk Config 1 Overview Port aggregation refers to the binding of several ports together to form an aggregation group where all member ports share the traffic thus connectivity reliability and bandwidth are boosted 2 To configure the aggregation port To enter the page below click Function Setting Trunk Config I ENDA 10 Port Gigabit Intelligent Pot Switch Microsoft Internet Explorer File Edt View Favorites Tools Help Osch EN a Pp Search she Favorites O CH d Address http 192 168 0 1 login Tenda System Information Port Management Function Setting PoE Config Trunk Config QoS Config _ SNMP Config VLAN Setting _ MAC Address Setting __RSTP Setting IGMP Snooping 802 1X Setting System Setting Find more productes of TENDA gt gt gt Trunk Configuration
35. figure below displays the detailed content of a 802 1Q tag header The priority field in TCI indicates 802 1p priority namely CoS priority which consists of 3 bits and has a value range of 0 7 TPID Tag Protocol Identifier TCI Tag Control Information teletele ELT a 65 e r a a r a e E a GB E r r 10 7 8 3 4 3 2 19 802 1Q Tag Header 3 DSCP Priority DSCP priority resides in an IP packet header where TOS field includes 8 bits The first 3 bits indicate IP priority with a value range of 0 7 The middle 4 bits bit 3 to bit 6 indicate TOS priority with a value range of 0 15 RFC2474 redefines the TOS field in IP packet header as DS field The DSCP Differentiated Services Codepoint priority is thus denoted by the first 6 bits 0 5bits in this field with a value range of 0 63 and the last 2 bits bit 6 and bit 7 are reserved Bits 012345 6 7 De 061234656 7 Preced i Type of i Service IPv4 ToS byte Differentiated Services Codepoint DSCP RFC 2474 IP Type of Service ToS RFC 7 DS Field and TOS Byte gt SNMP 1 Overview of SNMP SNMP Simple Network Management Protocol is used to guarantee that management information is transmitted between any two nodes in a network so as to make it more convenient for network administrators to retrieve modify information locate and diagnosticate malfunction plan out capacity as well as generate reports in any nodes on a network It a
36. for packets with DSCP the mapped DSCP priority takes effect for packets with tag butno DSCP the mapped tag priority takes effect and for packets without both DSCP and tag port priority takes effect QoS Status Table Internet TENDA 10 Port Gigabit Intelligent Por Switch Microsoft Internet Explorer Bile Edit View Favorites Tools Help Q x A Ps fervore Zi A Z Address 8 http 192 168 0 1 login Raa effect System Information HA Ern QoS Status Table Function Setting PoE Config Trunk Config Port ID Port Priority 802 1P tag priority 802 1P default priority DSCP priority G08 Config 1 lt SNMP Config 1 low Disable 0 Disable VLAN Setting 2 low Disable 0 Disable _ MAC Address Setting 3 low Disable 0 Disable _ RSTP Setting 4 low Disable 0 Disable IGMP Snooping 5 low Disable 0 Disable 802 1X Setting 6 low Disable 0 Disable System Setting Find more uctas of 7 low Disable 0 Disable 8 low Disable 0 Disable 9 low Disable 0 Disable 10 low Disable 0 Disable http 4 192 168 0 1 q0517submit Refresh Internet 25 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide On the above page select a priority type for a port and click the Apply button to activate your settings Fields on the above page are described as below Field J esengte o Port ID Displays a list of port numbers for current QoS
37. he Filter port VID or not Configure a default VLAN ID for the corresponding port Default value is 1 And options are available after the port joins multiple VLANs 30 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Note When two switches are inter connected to implement VLAN function the inter connected ports must be set to the same PVID value and port tag must be set to Tagged otherwise packets can not be forwarded correctly 3 6 MAC Address Setting 3 6 1 MAC Aging To enter the page below click MAC Address Setting MAC Aging TENDA 10 Port Gigabit Intelligent POE Switch Microsoft Internet Explorer Tex il Vi Favori I Ble Edt Ven Favorites Tools Help r Osch AG J search SG Favorites 2 ds LJ Wl G3 Address http 192 168 0 1 login v Go Links gt Gr l System Information MAC Aging Configuration Port Management _ Function Setting VLAN Setting ARL Aging v Enable MAC Address Setting Aging Time 10 65535 s MAC Aging Appl MAC Filter Static MAC J bled RSTP Setting IGMP Snooping 802 1X Setting System Setting Find more productes of TENDA gt gt gt http 19 i Internet Check the box to enable MAC address aging function and enter a time value in the aging time box then click the Apply button to activate your settings Field Description Check the box to enable MAC address aging function ot
38. herwise ARL Aging MAC addresses will not age out Aging Time Ranges from 10 to 65535 300s by default Note When address aging function is disabled the switch stops learning new MAC addresses and convert the existing MAC addresses in the table into static MAC addresses in the meantime The already learned MAC addresses will not become aged out 31 Tenda 3 6 2 MAC Filter TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide MAC filter function enables you to add the MAC addresses of PCs and other devices to the MAC address filter table so that they are prevented from accessing network through the switch This switch supports a maximum of 64 MAG address filter entries To enter the page below click MAC Address Setting MAC Filter TENDA 10 Port Gigabit Intelligent POE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help ga Q x 18 QD Osan se ravortes O A 3 Wh 3 Address http 192 168 0 1 login B 7enda System Information MAC Filter Port Management Function Setting VLAN Setting MAC Address Setting MAC Aging MAC Filter Static MAC RSTP Setting IGMP Snooping MAC Address 00 BO 4c 00 00 AA Add Address MAC address filter function enables you to add the MAC addresses of PCs and other devices to the MAC address filter table so that they are prevented from accessing network through the switch Note
39. if class 3 is detected then the allocated power it receives is 15 4W if the consumed power of the PD exceeds the port power limit pre defined by PD s class then the port will terminate power allocation to it and re detect it TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide in 5 seconds If the Static Allocation mode is selected then the power allocation is determined by the manually configured value per port If the actually consumed power of a PD exceeds the manually configured value on the port then the port will terminate power allocation to the PD and re detect it in 5 seconds If the Dynamic Allocation mode is selected then the power allocation is determined by the actually consumed power of the PD If the actually consumed power of the PD exceeds 15 4W then the connected port will terminate power allocation to the PD and re detect it in 5 seconds Power Utilization Displays the total PoE power utilization state Full power is PSE Temperature Temperature of the chip that electrifies the ports PoE Enabled Check to enable PoE function on the corresponding port by default this feature is disabled Delivering Displays the output power currently delivered by a Power W corresponding port Voltage V Displays the output voltage currently delivered by a corresponding port Current mA Displays the output current currently delivered by a corresponding port Priority If the utilized power
40. ig Snooping Status 802 1X Setting System Setting Find more productes of TENDA gt gt gt http 19 ii Internet This page displays the statistic data of the corresponding VLAN s IGMP multicast packets of different versions Fields on the above page are described as below Field Description S VLAN ID The VLAN with IGMP Snooping function enabled This field displays Idle when there is no established Querier multicast table and Active upon snooping on multicast packets Queries Transmitted Collects statistic data of the transmitted query packets Collects statistic data of the received query packets Collects statistic data of the received report packets of V1 V2 and V3 V2 Leaves Collects statistic data of the received leave packets of V2 V1 V2 V3 Reports 3 9 802 1x Setting 802 1X is a port based network access control protocol It enables the ports of a switch in a LAN to perform authentication and control operations on the devices that connects to 38 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide them if they pass the authentication they can access resources of the LAN and otherwise they can not This protocol mainly solves the problems of authentication and security in Ethernet 3 9 1 802 1x Setting To enter the page below click the 802 1x Setting 802 1x tabs A TENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Ex
41. ions will be deleted The default mode is Port VLAN gt Port VLAN configuration Click the Apply button to enter the configuration interface For details please refer to 3 5 2 gt 802 1Q VLAN configuration Select it and then click the Apply button to enter its configuration interface For details please refer to 3 5 3 3 5 2 Port VLAN To enter the page below click VLAN Setting Port VLAN TENDA 10 Port Gigabit Intelligent Pot Switch Microsoft Internet Explorer File gdt View Favorites Tools Help A Qa x 2 Per fervore O R 3 UDKA 3 Address http 192 168 0 1 login ei Blo im System Information Port VLAN Port Management Function Setting VLAN Setting VLAN Mode 1 S Port VLAN 802 1Q VLAN VLAN Member f 6 Tag VLAN Config _ MAC Address Setting Apply _ RSTP Setting _ IGMP Snooping VLAN Group 802 1X Setting System Setting Find more productes of TENDA gt gt gt VLAN Group Im VLAN Group VLAN Member http 192 168 0 1 portvlan submit Refresh Internet Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Procedures taken to add VLAN groups in Port VLAN mode are listed below 1 Select a VLAN group number such as 2 from the VLAN Group drop down
42. ire speed 148800 100Mb ire d Forwarding Rate ee 1488095pps 1000Mbps wire speed MAC Address Auto learning aging Learning Backplane 32Gbps Bandwidth Physical and Environmental Features AC Input Range 100 240V 1 5A Max 50 60Hz Operating 10 C 45 C Temperature Storage Temperature 40 C 70 C Operating Humidity 10 90 RH non condensing Storage Humidity 5 90 RH non condensing Heat Dissipation Fan mode Dimensions 440x209x44 mm Net Weight 2 94 Kg Gross Weight 3 65 Kg Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Chapter 2 Hardware Installation 2 1 Package Contents Please verify the contents to the following after you open the package 1 One switch 2 One AC power cord 3 One pair of l shaped brackets and matched screws 4 4 rubber cushions 5 One user manual The above listed items are for reference only for actual contents refer to the physical articles in the final package 2 2 Hardware Installation Description 1 To horizontally set the Switch on an operation desk follow instructions below Correctly attach the four included rubber cushions to the 4 corresponding positions on the bottom of the switch and then place the switch horizontally on a stable and solid operation desk Make sure there is sufficient ventilation as shown in the below figure Tenda teG1210P Hs On Oe e 00000004 Setting the switch on an operation desk 2 To mount the
43. led to configure IP address for configuration steps refer to appendix 4 2 3 1 2 Configuration Preparation For first time configuration we recommend you to connect the switch to a PC only instead of to many other devices to avoid IP collision The following table lists the default parameters of the Switch Parameter Default Value Default IP address 192 168 0 1 You can log in to the switch s configuration interface by following the steps below 1 Connect the switch to a PC s NIC 2 Power the switch 3 Check whether the IP address of the computer is within this network segment 192 168 0 ranging from 2 to 254 For the IP address configuration please refer to Appendix 4 2 11 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 4 Launch the browser enter http 192 168 0 1 and then press Enter The login page of the switch would appear as shown below ATENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help Q sax amp EN a A Fa Search S G Favorites 2 Gk d s jw LJ Address http 192 168 0 1 Sri tch IP 192 168 0 1 TENDA 10 Port Gigabit Intelligent PoE Switch Username admin Password 09090908 5 Enter the user name and password the default values are admin and then click Apply to log in to the switch s configuration interface ATENDA 10 Port Gigabit Intelligent PoE Switch Micr
44. list box 2 Check the ports to join the corresponding VLAN group in VLAN Member box 3 Click the Apply button to complete this operation 4 The member ports of VLAN2 are displayed in VLAN Group status table To refresh member ports of a VLAN group follow the above procedures for re configuration To delete all member ports of a VLAN group Select a VLAN group number from the VLAN Group drop down list box and then click the Apply button 3 5 3 802 1Q VLAN A Tagged VLAN uses port VID to distinguish different VLANs When frames pass through a switch the VID information in tag header is used to identify the VLANs to which they belong And the switch will then decide to which ports such frames should be forwarded according to current VALN configuration To enter the page below click VLAN Setting 802 1Q VLAN tabs as shown in the figure below E TENDA TOPON Gigabit Intelligent Det Switch Microsoft Internet Explorer File Edit View Favorites Tools Help r Ge i 2 J search she Favorites CH amp es Wl G3 Address http 192 168 0 1 login v Go Links gt y Tenda System Information 802 1Q VLAN Port Management Function Setting VLAN Setting ER 174094 VLAN Mode 1 2 3 4 5 Port VLAN 802 10 VLAN Port B 5 P ES Tag VLAN Config _ MAC Address Setting A
45. lue is the more likely it is for a switch to become a root bridge Hello Time The time interval at which a switch transmits a BPDU packet 2s by default The allowed value for configuration ranges from 1 to 10s MAX Age The max time for a bridge port to store configuration BPDU 20s by default The allowed value for configuration ranges from 6 to 40s Forward Delay The time between the listening state and learning state 15s by default The allowed value for configuration ranges from 4 to 30s STP Version Select RSTP or STP By default it is RSTP 34 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 7 2 RSTP Port To enter the page below click RSTP Setting RSTP Port TE saad Ga At POE Sech Microsoft Internet Explore a a e Search JKA 3 ss EI http 19 System Information RSTP Port Configuratio Port Management _ Function Setting Port Protocol Enabled Edge Path Co et VLAN Setting MAC Address Setting _RSTP Setting RSTP Config RSTP Port _ RSTP Status IGMP Snooping 802 1X Setting System Setting Fil This page allows you to view and modify RSTP port settings Fields on the above page are described as below Field Deseription O Switch s Port ID number Enable or disable RST
46. m switch s web based Logout configuration interface 3 2 System Information To enter the following page click System Information BE TENDA 10 Port Gigabit Intelligent View avorite Took el PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help r Osch H EN a Le p gt Search se Favorites Le ME LJ Ra gt 3 S Address 7 http 192 168 0 1 login v Go Links G l System Information System Information Port Management Function Setting Hardware Version vun A VLAN Setting Firmware Version vio T MAC Address Setting DHCP Client Disable _ RSTP Setting VLAN Mode 802 10 VLAN _ IGMP Snooping IP Address 802 1X Setting Subnet Mask System Setting I Find more productes of Gateway 0 0 0 0 TENDA gt gt gt MAC Address 00 011 c1 00 00 01 ARL Aging Time 300 seconds This page displays the switch s system parameters which are described as below Hardware Version Switch s hardware version Firmware Version Switch s firmware version VLAN Mode Displays the current VLAN mode DHCP Client Displays DHCP client status by default the feature is disabled IP Address Switch s IP address 192 168 0 1 by default through which TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide you can log in to its web based configuration page to manage the device Subnet Mask Switch s subnet mask value 255 255 255 0 by default
47. member box as 29 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide shown in the above figure 3 Click the Apply button to complete the configuration The VLAN 4094 will be displayed in VLAN list as shown below VLAN ID VLAN Port Member Operation 1 1 2 3 4 5 6 7 8 9 10 4094 2 3 Delete 2 To delete a VLAN just click the corresponding Delete button 3 5 4 Tag VLAN Config To enter the page below click VLAN Setting Tag VLAN Config tabs SA TENDA 10 Port Gigabit Intelligent Por switch Microsoft Internet Explorer System Information VLAN Port Configuration Port Management Function Setting _ VLAN Setting VLAN Mode 1 Port VLAN 2 802 10 VLAN Tag VLAN Config 3 MAC Address Setting 4 RSTP Setting 5 6 7 8 9 Port Port Tag Ingress Filter PVID IGMP Snooping 802 1X Setting Untagged v System Setting Find more productes of TENDA gt gt gt Fields on the above page are described as below Field Description S Configure tag property for the corresponding port namely forwarding rule Generally Untagged rule is usually selected for a port that connects a terminal while Tagged rule is chosen for a port that connects a switch Ingress Decides whether to accept a tagged frame that does not match t
48. modify the SNMP information of Write Community the switch SNMP management software must contain the same write community name SNMP Used by the SNMP management software to judge the validity Trap Community of trap message by identifying the trap community name 3 5 VLAN Setting The switch supports 2 types of VLANs Port VLAN and 802 1Q VLAN by default it is in Port VLAN mode 27 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 5 1 VLAN Mode To enter the page below click VLAN Setting VLAN Mode tabs a TENDA TO Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help a Qa x A CD Ps ferve O r 5 m Si 3 Address E http 192 168 0 1 login zl Be Links 7 Fenda System Information VLAN Mode Port Management Function Setting _ VLAN Setting VLAN Mode Port VLAN Notes When either of the VLAN modes is enabled configurations of the other one will be deleted 802 10 VLAN Tag VLAN Config MAC Address Setting RSTP Setting IGMP Snooping 802 1X Setting System Setting Find more productes of TENDA gt gt gt Port VLAN 802 10 VLAN http 192 168 0 1 vlanmode submit Refresh Internet This page allows you to select the port based VLAN or 802 1Q VLAN mode When either mode of the two is enabled the other one will be disabled automatically and its configurat
49. n Auto Negotiate Down Enable http 192 168 0 1 ports submit Refresh Internet To configure a port click the Port drop down list box and select a number for example 1 After you finish the needed configurations click Apply to activate them Fields on the above page are described as below Field Description S The port number corresponding to that on switch s panel Admin Enable Allows you to configure to Enable or Disable a port If Disable Disable is selected then the corresponding port can not be used Note DO NOT disable a port unless for some special needs Auto negotiate Enable or disable port auto negotiation function By default it is enabled on all ports TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Speed Duplex Allows you to manually configure 5 working modes 10Mbps half duplex 10Mbps full duplex 100Mbps full duplex 100Mbps half duplex and 1000Mbps full duplex Note only after auto negotiation is disabled can duplex mode be configured Flow Control IEEE802 3x in full duplex and backpressure flow control in half duplex are supported Switch automatically changes flow control according to a port s duplex mode The actual information of each port is displayed in the Port Status table below Port Status Port Fink pe or Speed Duplex Status ntro Down own nable 100Mbps Full Down own nable own Down Down own nable ow
50. n Down Down own nable own Down Down own nable own Down 3 3 2 Mirror Config Port mirroring function is implemented by copying packets through one or more monitored ports to a monitoring port mirroring destination port for the purpose of analyzing and monitoring packets For example you can copy packets through monitored port mirroring source port 3 to monitoring port mirroring destination port 4 so as to test and record the working status of port 3 through the protocol analyzer connected to port 4 Through proper configuration TEG1210P can support cross VLAN and cross switch VLAN port mirroring To enter port mirroring configuration interface click Port Management Mirror Config as shown below The configuration procedures are listed below 1 Select a mirror port monitoring port from the Mirror Port drop down list box only one mirror port is allowed 2 Check one or more ports for mirrored port s in mirrored port box 3 Click the Apply button to complete the configuration 17 TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Tenda ATENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help ay Qa x AG Per Jerves OG Ar amp LR 3 Address http 192 168 0 1 login ly Bo us amp MN Tenda
51. ng specify a port Note A maximum of 64 static MAC address entries are allowed System Semi r ran Static MAC Address Table Find more productes of TENDA gt gt gt NO Source MAC Port ID Operation Delete All http 192 168 0 1 mac_static submit Refresh Internet 1 Steps taken to add a static MAC address are listed below 1 Enter a MAC address such as 00 B0 4C 00 00 10 in the MAC address box 2 Select a port ID number from Port ID drop down list box to implement port and MAG address binding 3 Click the Add Address button to complete the configuration 4 View the static MAC address table It should display the added MAC address as shown below SI TENDA TO Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer Ele Edt wiew Favorites Tools Help Qa O x 2 CD Ps ferve O R 5 DUK u 3 Address E http 192 168 0 1 login Fenda System Information Static MAC Address I Port Management Function Setting VLAN Setting MAC Address MAC Address Setting Port ID 1 ll MAC Aging Add Address MAC Filter Static MAC 1 To allow some network devices to be fixedly connected to the switch and keep their MAC addresses un refreshed you can add them to the BS eng levice to connect to the switch via a specific port only you can just add its MAC address to the static address
52. ng time MAC Address Displays and allows you to configure the MAC MAC Filter addresses of devices that are prohibited from Setting passing the switch Displays and allows you to configure static Static MAC MAC addresses Displays and allows you to configure RSTP RSTP Config system priority hello time aging time forward delay time and STP version RSTP Setting Allows you to enable RSTP and configure RSTP Port edging port and port path cost Displays the RSTP bridge overview and port RSTP Status status Displays and allows you to configure IGMP Snooping Config IGMP snooping function Snooping l Displays IGMP query report and leave frames Snooping Status o statistic data Displays and allows you to configure 802 1x 802 1x l function 802 1X Displays and allows you to configure 802 1x Setting 802 1x Port port control modes and forced re authentication Allows you to modify the password for logging Change Password in to the switch Allows you to enable power save function Upgrade Allows you to update switch s firmware 14 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide System Allows you to set switch s management IP and IP Config Setting VLAN etc Restore Factory Default Allows you to backup switch s current settings Allows you to restore previous settings Allows you to restore factory default settings Warm Restart Allows you to restart the switch Allows you to log out fro
53. nnnnseennn 26 PAN 27 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 3 5 1 VLAN Mode E 28 35 2 Port NN 28 3 5 3802 TFQ VLAN EEE NE 29 5 54 Tag VLAN COMING EE 30 3 6 MAC Address dn e EE 31 36 1 MAC AINO EE dieu l dincubied aeriana iana titans 31 3 6 2 MAC Filte AEE EEE ENE 32 3 60 3 Static EE 33 RTP Setting ER 34 RR ed 34 RTP PM 35 RTP StatUS ekke 35 3 8 IGMP S N 37 3 8 1 Snooping CONFIG BEE 37 3 8 2 Snooping Status eege eegene REENEN 38 8 9 GUL 1X SSUIN Oi E 38 3 9 1 CO gt Setting EEE ORTEN Ta EET 39 NTN an e en a E E E E 40 3 10 System SC UI REE NTS 41 3 10 1 Change Password RE 41 3 10 2 Ge EE 41 3 10 3 Firmware D ee Tee E 42 3 10 4 IP Ede benker 43 3 10 5 Restore Factory Dea eiiccciissicessvetincwasvocdiuisidinecateacabverds wdenkensesdebeduavvndicds 44 3 10 60 e E 44 3 107 REESE 45 3 10 8 Warm RES CANE aaicccassaietaataaacimatancnadecumaddadsinadidentiacaade gia indansdduoatinaderausdeanien 46 EE Eege 46 CHAPTER A APPENDIXES ennnnnnovvrnvnnnnnnnnevnnnnnnnnnnennnnnnevrnnnnnnnenevernnnnnnnnnnennnnnnnnnnnnnnnnnr 47 4 1 Appendix 1 GOSS AY Lue 47 4 2 Appendix 2 How to Set TCP IP Windows XP is used as an example 52 4 3 Appendix 3 Solutions to login failure cece cececccneeeeeeeeeeeeeeeeeeeseeeeeeeeaaeeeeeaaes 55 4 4 Appendix A Useful Commands rrrr
54. olve your problem 4 4 Appendix 4 Useful Commands Command Explanation r Run this command to enter the Windows command mode cm Suitable for Windows 2000 or higher Display the computer s IP address The most useful command in TCP IP protocol When it sends a serial of packets to another system the system will send back a ping response It is useful for checking remote host The response shows whether it can reach the host and how long it costs to receive a response Run this command to check the current connection status of IP OE When your basic communication is processing the system service must be checked The service includes checking the input data or verifying the session i P Tracert command is used to display the path which the packets race pass through Stop Windows NT Network Service such as net stop dnscache 4 Send messages to other network users or computers You must net sen run messenger service to receive messages 56 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide 4 5 Appendix 5 Regulatory Statement FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in a
55. om the new firmware Click the Browse button to select a correct upgrade file and then click Upgrade The screen changes to the figure below when the process bar indicator displays 100 If the Yes button is clicked system restarts with the new firmware and automatically starts re login in 10 seconds 42 3 10 4 IP Config lok Switch Microsoft Internet Explore Q B E Ce JO search J Favorites EC ds LW RK a 3 Address http 192 168 0 1 login x Bo im Tenda Port Management ei Firmware successfully loaded Function Setting VLAN Setting MAC Address Setting RSTP Setting Yes No Do you want to activate new firmware IGMP Snooping 802 1X Setting Note Press Yes the switch will reboot After reboot It will run by new firmware System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart http 192 168 0 1 juploadfr htm internet To enter the page below click System Setting IP Config TENDA 10 Port Gigabit Intelligent Det Switch Microsoft Internet Explorer File Edit View Favorites Tools Help aR Qx SES Search p Favorites 2 ly 2 LIK Ki Aire 55 http 192 168 0 1 logi IG System Information Configure IP Address Port Managem
56. on the navigation menu column ATENDA 10 Port Gigabit Intelligent Po Switch Microsoft Internet Explorer File Edit View Favorites Tools Help a Q x 18 Osan Jeres O FI 3 Whe 3 Address http 192 168 0 1 login ly Bo ue gt amp MN Tenda System Information Rate Limit Configuration Port Management Port Config j Mirror Config Port Ingress Egress Pot Ingress Egress Rate Limit Storm Control Statistics Function Setting VLAN Setting MAC Address Setting RSTP Setting IGMP Snooping Apply 802 1X Setting System Setting Find more productes of TENDA gt gt gt No Limit No Limit No Limit No Limit f No Limit a No Limit NoLimit No Limit 2 No Limit No Limit 4 No Limit No Limit 6 e No Limit v No Limit v No Limit No Limit KJK E s a v No Limit sel No Limit se 10 NoLimit el No Limit http 192 168 0 L ratelimit submit Refresh Internet Rate limit can be used to limit the TX and RX rates on each port It can effectively avoid 18 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide excessive bandwidth utilization due to some users excessive downloading activities so that other users can have a guaranteed share of the bandwidth to enjoy a smooth network After you selected the Ingress Egress RX TX rates click the Appl
57. ormation Port Management Port Tx Bytes Tx Frames Rx Bytes Rx Frames Tx Errors D 0 D D 107328 493 462732 6786 0 D IGMP Snooping 802 1X Setting System Setting Find more productes of TENDA gt gt gt esl lelel leleleol leo ea co o E CSR HRC S e 6 6 http 192 168 0 1 stormctrl submit Refresh Internet This page displays RX TX packet counts TX RX byte counts and RX TX error packet counts To delete port statistic data click the Clear button To refresh the statistic data click the Renew button Fields on the above page are described as below 20 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Field Description Port Port ID TX Bytes The transmitted byte count of a port The transmitted frame count of a port RX Bytes The received byte count of a port RX Frames The received frame count of a port The transmitted error frame count of a port The received error frame count of a port 3 4 Function Setting 3 4 1 PoE Config 1 Overview gt PoE Power over Ethernet refers to the scheme that collaterally implements power delivery and data transmission A PoE device provides remote power delivery to a remotely connected PD through an electrical port and a twisted pair cable gt Advantages of PoE 1 Reliable concentrical power delivery budget for the whole system easy backup unitive man
58. osoft Internet Explorer File gdt View Favorites Tools Help Gan O HAE Pan frue O E D a ESA Address http 192 168 0 1 login x Bo uns gr x System Information TENDA 10 Port Gigabit Intelligent PoE Switch Port Management Function Intro Function Setting VAN Setting PoE Power over Ethernet VLAN Qos Storm Control _ MAC Address Setting PSE PoE function supported e Portbased e Priority mapping e Broadcast and in _ RSTP Setting on ports 1 8 VLAN Multicast control IGMP Snooping 802 3af e 802 10 VLAN e Flood control 802 1X Setting Mirror MAC Control System Advance System Setting EE e Control multi ports MAC Filter e Backup Restore e IGMP Snooping e Across VLAN e Static MAC e HTTP firmware e STP RSTP upgrade e 8021X e security e SNMP V2c EI Done Internet 3 1 3 Configuration Interface Description Log in to the switch s web based management page and click a menu on the menu navigation panel to enter the corresponding configuration page Descriptions of the menus and their correspondingly linked pages are listed in the table below 12 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Menu Submenu Linked Page Function System DEN Displays switch s system parameters Information Displays and allows you to make basic Bar Goan configurations for each port of the switch such ort Confi i as link status speed duplex and flow control etc
59. pe can belong to multiple VLANs to transmit frames to and receive frames from multiple VLANs They are usually used in inter switch connection gt STP 1 STP STP Spanning Tree Protocol which is based on IEEE802 1d standard is used to eliminate potential physical loop in data link layer in a LAN Devices that run this protocol exchange packets to discover potential loops in a network and optionally block some ports to trim the looped network architecture into a loop free tree shaped one As a result packets are prevented from incrementing and endlessly repeating in a looped network and devices abilities to handle packets are also prevented from degrading due to repeatedly receiving the same packets STP includes two senses In a narrow sense it is the STP defined in IEEE802 1d and in a broad sense it includes IEEE802 1d defined STP and all other STP enhancements based on IEEE802 1d 2 RSTP RSTP Rapid Spanning Tree Protocol completely compatible downwards with 802 1d STP mostly features a faster convergence function in addition to the avoiding loops and redundant link functions that classic STP has If all bridges in a LAN support RSTP and the administrator have configured appropriately it takes a quite short time to regenerate a topology tree classic STP needs about 50 seconds while RSTP needs a minimum of 1 second once network topology changes RSTP can switch to forwarding state fast without depending on counter setting
60. plorer File Edt yi avorites ls Help Ble E avorites Tools He Gea pl EG sem she Favorites 2 3 JKA 3 Address ZE http 192 168 0 1 login v Go Links System Information 802 1X Configuration Port Management Function Setting 802 1X Enabled Enable VLAN Setting RADIUS IP 0 0 0 0 MAC Address Setting _ RSTP Setting _ IGMP Snooping 802 1X Setting 802 1X 802 1x Port RADIUS UDP Port 1812 RADIUS Key Enable 3600 1 3600 seconds EAP timeout 30 1 255 seconds System Setting Find more productes of Apply TENDA gt gt gt Enter the needed parameters for 802 1x configuration on the above page and click Apply to activate your settings Fields on the above page are described as below EEE gt Check to enable or uncheck to disable 802 1X function on the 802 1x Enabled switch s ports Radius IP The IP address of the authentication server RADIUS UDP Port Set the authentication UDP port of the switch 1812 by default Configure this value according to the secret key corresponding RADIUS Key to the authentication server Reauthentication Enable or disable re authentication if this feature is enabled 39 TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide enda Enabled switch will require re authentication of client regularly Reauthentication Configure the cycle of reauthentication 360
61. pply RSTP Setting IGMP Snooping A Tagged VLAN uses port VID to distinguish different VLANs When frames pass through a switch the VID information in tag header is used to identify the VLANs to which they belong And the switch will then decide to which ports such frames should be forwarded according to current 802 1X Setting VALN configuration The three steps taken by the switch for handling this process are described as below System Setting 1 Deciding the VLAN to which a frame belongs namely input rule lf a frame contains a tag header and the VID in this tag is valid then this ME mus productos of frame belongs to the VLAN denoted by the VID otherwise system will determine the VLAN according to the default VID of the port that receives TENDA gt gt gt the frame 2 Deciding the port to which the frame should be forwarded namely forwarding rule After the VLAN to which the frame belongs is determined the frame will be forwarded to the VLAN s member ports the VLAN ID is 1 by default and you can modify it in VLAN port setting 3 Deciding the changes needed in frame output namely output rule Options available include tagged untagged or unchanged http 192 168 0 1 tagvlan submit Refresh Internet 1 Steps taken to create a VLAN group are listed below 1 Enter a new VLAN ID such as 4094 in the VLAN ID box The allowed ID value ranges from 1 to 4094 2 Check the port numbers such as 1 2 3 to join VLAN 4094 in VLAN
62. rnnnnnrvnnnnnrrnnnnnrrrnnnnerernnnerernrnnrrennnnssrnnnnsreennnn 56 4 5 Appendix 5 Regulatory Giatement rr trernnensrrne 57 4 6 Appendix 6 Technical Support ANEREN 58 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Preface Thanks for purchasing this switch from Shenzhen Tenda Technology Co Ltd It is a great honor to have you as one of our product users About this user manual This user manual is designed to familiarize you with the switch and instruct you in the use of it It introduces the functional features and installation methods of this TEG1210P 10 Port Gigabit Intelligent PoE switch as well as security warnings Note Please do peruse all related documents for your first time use of this switch It will help you make better use of this product Security Warnings Be sure to read this manual carefully before using the switch For your safety Do NOT open the switch s shell outer case whether it is working or not The switch functions normally only with correct voltage so make sure the operating voltage accords with that denoted on its panel amp Protect it against strong current or lightning The switch is an electrical device be sure to protect it against water and humidity so as to avoid short circuit and malfunction Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Chapter 1 Product Introduction TEG1210P a 10 Port Gigabit Intelligent PoE Switch
63. s any more RSTP bridge is very sensitive to other 50 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide RSTP bridge links there is no need for ports to keep waiting until topology becomes stable gt IGMP Snooping 1 The implementation principle of IGMP Snooping IGMP Snooping run on data link layer is a multicast management scheme which works on layer 2 switch to manage and control multicast group When a layer 2 Ethernet switch receives IGMP packets transmitted between hosts and routers the IGMP Snooping function starts analyzing the messages carried in the IGMP packets When snooping to learn that a host has sent an IGMP host report frame the switch will add this host to the corresponding multicast table and when snooping to learn that the host has sent an IGMP leave packet it will delete the corresponding multicast entry Through continuously snooping on IGMP packets the switch creates and maintains a MAC multicast address table in layer 2 environment And according to this table it forwards the multicast packets from routers 2 The relation between IGMP Snooping and VLAN VLAN technology namely virtual local area network is introduced to switch for the main purpose of restricting broadcast domain To better combine the two to implement multicast in VLAN environment multicast groups created by IGMP Snooping should be confined to VLAN broadcast domain Thus in the VLAN environment not only the
64. server and then re connect switch Don t enable this function unless you are aware of the IP address assigned by DHCP server Please be careful when using it 3 10 5 Restore Factory Default To enter the page below click System Setting Restore Factory Default 2 TENDA 10 Port Gigabit Intelligent Por Switch Microsoft Internet Explorer S File Edt View Favorites Tools Help a Q MAG Pus krs B DAA 3 Address http 192 168 0 1 login v Bo uns G e Restore Factory Default Function Setting _ VLAN Setting MAC Address Setting _ RSTP Setting IGMP Snooping 802 1X Setting Please press Apply to start to restore factory default configuration Apply System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout Find more productes of TENDA gt gt gt http 192 168 0 1 Factory htm internet This page allows you to restore switch s default settings To restore click the Apply button Note If you have modified switch s default IP address you still must use the default IP address 192 168 0 1 to re log on to the switch s configuration interface after switch system restores factory default values Both default user name and password are admin 3 10 6 Backup To enter the page below click System Setting Backup 44 TEG1210P 10 Port Gigabit Intelligent
65. system priority and MAC address Fields in the RSTP Port Status table on the above page are described as below Port ID Path Cost Displays port path cost values daa Port Displays Yes or No Yes indicates the corresponding e Por S port is a edge port while No indicates the opposite meaning POP Port Displays Yes or No Yes indicates the corresponding or port is a point to point port while No indicates the opposite TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide meaning Note P2P is a scheme to speed up convergence in RSTP Most ports in Ethernet are of this type Protocol Displays STP or RSTP The port state in current STP Such as forwarding disabled Port State blocking learning and no STP 3 8 IGMP Snooping 3 8 1 Snooping Config To enter the page below click IGMP Ee Snooping Sonig EE Le T Intelligent Po Sech Microsoft Internet Explorer File Vien orites Tools Help 2 A0 P Favorites 2 amp LR 3 s5 EI http 19 System Information IGMP Configuratio Port Management Function Setting VLAN Setting oe Enable Es i _ MAC Address Setting Router Ports 1 P 3 4 5 6 p 8 E 10 RSTP Setting IGMP Snooping Snooping Config Snooping Status 802 1X Setting VLAN ID IGMP Snooping Enabled IGMP Querying Enabled System Setting Find more pro
66. te jitter control and delay for real time and interactive flow packet dropping probability and specifying network flow for different WAN and LAN In the meantime it guarantees that every flow with provided priority will not affect other flow s process QoS is a network security mechanism which is used to solve problems like network delay and congestion etc In normal circumstances if a network only works under specific timeless application systems then it does not need QoS such as web application or E mail etc However QoS technology is quite necessary for some key applications and multimedia application It guarantees that important data flows are not delayed or discarded when network is overloaded or congested Thus a highly efficient network is guaranteed 2 802 1P Priority 802 1p priority that resides in layer 2 frame s header adapts to the environment that requires a guaranteed QoS in layer 2 environment instead of analysis of layer 3 frame header Only frames with 802 1Q tags have 802 1p priorities The 4 byte 802 1Q tag header consists of 2 byte TPID Tag Protocol Identifier with a value of 0x8100 and 2 byte TCI Tag Control Information as shown in the figure below 802 10 inati Sour head Destination SE ce steel Length Type ES ress i i Va 6 bytes 6 bytes 4 bytes 2 bytes 46 1500 bytes 4 bytes Ethernet Frame with 802 1Q Tag header 47 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide The
67. ted ports for a trunk group which is allowed to have a maximum 1 2 3 of 4 ports and a minimum of 2 ports Trunk Supports source MAC address destination MAC address and Arithmetic source amp destination MAC address By default the algorithm is Choice based on source and destination MAC address 24 TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Tenda Note 1 Once a port is set as a member of a trunk group it can not be used for other purposes except for this trunk group whether it is being used by this trunk or not 2 Cross VLAN trunk is not supported that is all trunk group members must be on the same VLAN otherwise trunk function will fail 3 All member ports in a trunk group must share the same configurations including duplex mode and rate configurations etc 3 4 3 QoS Config QoS is the technology that solves the problems of network delay and congestion It guarantees that important data flows are not delayed or discarded when network is overloaded or congested Thus a highly efficient network is guaranteed To enter the page below click Function Setting QoS Config TENDA 10 Port Gigabit Intelligent POE Switch Microsoft Internet Explorer File Edit View Favorites Tools Help a Q x 2 Ps Jerves O R 3 WK Ge 3 Address http 192 168 0 1 login v Bo uk d bene http 192 168 0 1 q0517submit Refresh
68. ting Power Save enable VLAN Setting MAC Address Setting _ RSTP Setting _ IGMP Snooping 802 1X Setting System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout http 192 168 0 1 power_save submit Refresh Internet Power Save To enable this feature check the box and click the Apply button 3 10 3 Firmware Upgrade To upgrade firmware click System Setting gt Upgrade TENDA 10 Port Gigabit Intelligent PoE Switch Microsoft Internet Explorer Bile Edit View Favorites Tools Help PI Q x 2 G Peach ferries O R LIKI 3 Address http 192 168 0 1 login Bo uns Tenda System Information Firmware Upgrade Port Management Function Setting VLAN Setting Current firmware version v1 0 MAC Address Setting Open the firmware Browse _ RSTP Setting Upgrade IGMP Snooping 802 1X Setting NOTE upgrade failure will not cause malfunction Please select a correct upgrade file and start re upgrade when the failure occurs System Setting Change Password Power Save Upgrade IP Config Restore Factory Default Backup Restore Warm Restart Logout fei http 192 168 0 1 uploadr htm Internet Current firmware version is displayed on above page to distinguish fr
69. ts port aggregation Trunk and provides 3 trunk groups each of which is allowed to include a maximum of 4 member ports 5 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Supports up to 10 groups of Port based VLANs Supports up to 128 groups of IEEE 802 1Q Tag VLANs with VLAN IDs ranging from 1 to 4094 Supports static MAC address table with up to 64 entries and MAC address filter Supports 802 1w RSTP and is compatible with 802 1D STP Supports port storm control statistics bandwidth control QoS IGMP snooping and 802 1x etc Built in high performance switching mode power supply supports AC 100 240V 1 5 A MAX 50 60Hz input 1 2 Technical Specification General Features EEE802 3 IEEE802 3u IEEE802 3ab IEEE802 3x IEEE802 3z IEEE802 3af IEEE802 1p IEEE802 1Q IEEE802 1D IEEE802 1w IEEE802 1x Protocols CSMA CD Ethernet Fast Ethernet Gigabit Ethernet Transmission Rate 100Mbps Chalf duplex 2000Mbps full duplex 200Mbps full duplex Topology Structure 10 100Base TX CAT 5 UTP STP 100m 1000Base Tx CAT 5e UTP STP 100m above 1000Base LX SMF MAX 10km 1000Base SX MMF MAX 550m 1000Base LHX SMF MAX 50km 1000Base ZX SMF MAX 80km Standards Network Cable 8 10 100 1000Mbps auto negotiation Ethernet ports 2 SFP ports Characteristics Port Quantity Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide Forwarding Scheme Store and forward 14880pps 10Mbps w
70. x Go Links gt A Fi System Information PoE Power over Ethernet Configuration Port Management Function Setting Power Management Mode PD Based Priority Static Allocation Dynamic Allocation PoE Config Power Utilization ows 120 W Trunk Config PSE Temperature aE QoS Config r l Ne ccnn Port PoE Enabled Delen oC Voltage V Current mA Priority Si All ion W VLAN Setting w MAC Address Setting 1 0 D D Low 0 RSTF Soting 2 o o o Low 0 IGMP Snooping 802 1X Setting 3 g d g Ew i System Setting 4 0 D D Low 0 Find more productes of TENDA gt gt gt 5 Oo Oo 0 Low 0 6 0 D D Low 0 7 a 0 D Low 0 1 http 19 i br fr Internet This page allows you to flexibly control port PoE power distribution enabling a specific port to implement normal electrification in a full charge electrification state The fields on the above page are described as below Fields on the above page are described as below Fia Description S Power There are three power management modes PD based priority Management static allocation and dynamic allocation Mode If the PD based priority is selected then the power allocation is determined by based on PD s class For a PD if class 0 or 4 is detected then the allocated power it receives is the actual power consumed by itself if class 1 is detected then the allocated power it receives is 4W if class 2 is detected then the allocated power it receives is 7W
71. y button to activate them Fields on the above page are described as below Field Description S Displays switch s port numbers Configuration of RX TX rate on a specific port can be made in the corresponding configuration box after the port field Ingress The packet RX rate of a corresponding port ranging from 5 to 155Mbps The default value is No limit Egress The packet TX rate of a corresponding port ranging from 5 to 155Mbps The default value is No limit Note If the selected rate is higher than the actual link rate of the port the value displayed on the window is the selected value instead of the actual one 3 3 4 Storm Control To enter storm control configuration interface click Port Management Storm Control as shown below PA TENDA 10 Port Gigabit Intelligent Pot Switch Microsoft Internet Explorer File Edit View Favorites Tools Help Osch EN a Search he Favorites O 2 Address http 192 168 0 1 login Fenda System Information Storm Control Port Management Port Config Broadcast Rate No Limit ze Mirror Config Rate Limit Multicast Rate Storm Control Statistics re Gli 1 The settings here above reported permit for the specific BROADCAST MULTICAST UNKNOWN UNICAST traffic the fixing of a upper limits _ Function Settin g on the number of frame seconds 2 The switch port blocks traffic when the rising threshold is reached
72. y partition network devices on a local network into several network segments so as to implement virtual workgroup technology It allows network administrators to logically partition a physical LAN into various broadcast domains namely VLANs Each VLAN consists of a group of PCs with the same demands Since VLAN is logically instead of physically partitioned PCs in the same VLAN do not need to be confined to the same physical space in other words these PCs do not necessarily don t need to belong to the same physical LAN net segment 2 Tag VLAN Port After 802 1Q VLAN mode is enabled all ports will have default VIDs namely PVID which can only influence switch s external actions but can not affect its internal forwarding rule at all For tagged frames matching the port s PVID any type of ports adopts the same 49 Tenda TEG1210P 10 Port Gigabit Intelligent PoE Switch User Guide forwarding rule namely stripping off their tag headers so that they can be identified by common devices The following lists 2 common port types for tagged VLANSs eo Access Type The forwarding rule for this type is to strip off the tag headers of all frames that are to be forwarded Generally this type of ports only belongs to 1 VLAN and is usually used to connect switches to terminal devices Trunk Type The forwarding rule for this type of ports is not to change the tag headers of frames that do not match the porte PVIDs Ports of this ty