Home

AMX HPX-1600

image

Contents

1. an F Installation Manual HPX 1600 Retractable Connection Port and HPX Modules Environment Accessories Last Revised 4 27 2012 AMX Limited Warranty and Disclaimer This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which include AMX Dealers Distributors VIP s or other AMX authorized entity AMX warrants its products to be free of defects in material and workmanship under normal use for three 3 years from the date of purchase with the following exceptions Electroluminescent and LCD Control Panels are warranted for three 3 years except for the display and touch overlay compo nents are warranted for a period of one 1 year Disk drive mechanisms pan tilt heads power supplies and MX Series products are warranted for a period of one 1 year AMX lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products as long as the AMX lighting products are under warranty AMX also guarantees the control of dimmable loads that are properly con nected to our lighting products The dimming performance or quality there of is not guaranteed impart due to the random combi nations of dimmers lamps and ballasts or transformers AMX software is warranted for a period of ninety 90 days Batteries and incandescent lamps are not covered under the warranty AMX AutoPatch Epica Modula Modula Series
2. Install the router bit into the router with an appropriate portion of the bit exposed below the guide bushing 5 Switch the router on and carefully lower plunge the router bit into the mounting surface within the template opening 6 Move the router against the template opening such that the guide bushing follows along the template opening 7 Carefully follow the template opening with the guide bushing in a clockwise fashion such that the cutting action of the router bit is acting against the motion of the router 2 Make several passes with the router guide bushing and router bit 9 Lower the router bit in small increments to remove a suitable amount of material on each pass surface Q Trying to cut too deep in any one pass may result in damage to the mounting CAUTION Take care to ensure that the top surface of the mounting surface is not damaged beyond the width of the trim bezel as the cutout is made Make sure the bit or cutting tool used is appropriate for the material to be cut and will not tear or chip the top surface AMX does NOT recommend using a Jigsaw to make the final cutout Note that the process of making the cutout will create substantial dust and prepare the environment appropriately 10 Finally remove template by pulling firmly on the rounded edges of the double sided tape mounting strips until they release from the tabletop and template Step 3 Prepare the Terminations Some modules that are
3. Cover AC Power connector inside view FIG 13 Bottom Cover Connect each AC power module to the power inlet assembly 2 Ensure the Power Inlet Assembly Chassis Ground Lug is secured tightly to the HPX 1600 Chassis using the included grounding screw FIG 14 Grounding screw 4 HPX 1600 Chassis Grounding screw Aluminum Frame bottom connects here Power Inlet Assembly Chassis Ground Lug Bottom Cover mounting screws FIG 14 Installing the Bottom Cover 3 Route the remaining cables out of the bottom cover using the four square holes provided in the bottom cover E ss li 4 Secure the bottom cover to the aluminum frame using the four provided screws 5 Secure the cables exiting the bottom cover using the provided wire ties FIG 15 Wire Tie secured with 4 mounting screws HPX 1600 Chassis Aluminum Frame bottom FIG 15 Bottom Cover Installed With Cables Exiting and Secured Step 6 Install the Lift Spring Assemblies ATTENTION If modules have been installed in more than 50 of the available space the performance of the HPX 1600 retract mechanism may benefit from the installation of the optional accessory HPX AC HSP FG559 42 See the installation guide for HPX AC HSP for further details After the bottom cover is fully secure and the exiting cables are secured 1 Clip both lift spring assemblies onto the mounting sleeve 2 Ensure the lift spring assembly is oriented prop
4. Double sided mounting strips i BP at MERA Alignment Marks _ 39 PI TMPLA S39 90 iti i a AAA j HPL AC TH e r ree oF ese oe Vere obs Rda tee Double sided mounting strips PESE 5 OSA aaa o e a o me FIG 5 HPX AC T Router Template e Note that due to the guide bushing and router bit the final cutout will be smaller than the opening in the template The cutout in the mounting surface will be offset to the inside of the template opening by 1 8th inch 3 2 mm on all sides Note both the position and orientation of the template relative to the table top or other mounting surface Note that very little clearance exists between the Hydraport assembly and the hole cutout in the mounting surface Take care to align the cutout carefully with the edges or other appropriate features in the table or mounting surface If the cutout is misaligned the installed unit will be misaligned Ensure the template is held securely on the mounting surface If the template moves during the cutting process the cutout will be enlarged O and will likely exceed the trim bezel of the Hydraport base CAUTION assembly requiring extensive repair to the mounting surface 4 Install the router guide bushing into the base of a suitable router The router should be equipped with a Y2 inch 12 2mm collet and a baseplate capable of accepting a standard 1 3 16 inch 30 2mm guide bushing
5. E 31 T l REUS sa TAE EE 31 Step 1 Install Low Voltage Secondary Circuit Modules ooocooocoooccooconocnnocononoso 32 Step 2 Fold the High Voltage Isolator oooocooccooccoooconononoconoconoconcconcconccnncconoconos 32 Step 3 Insert the High Voltage Isolator ooooooocoooccoonnnononoconoconoconoconoconcconcconoconos 32 Step 4 Mark and Trim High Voltage Isolator ooocoooccooccooncnononoconoconoconoconocnnoos 33 Step 5 Install AC Mains Power Outlets ooocooccconoccncccoccnocconcnncconcnncnnoconcnoccnnconos 33 EEE ad Table of Contents ii HPX 1600 Retractable Connection Port HPX 1600 Hydraport Overview The HPC 1600 HydraPort Retractable Connection Port FG550 cc is the first completely modular retractable cable connection system built to accommodate the diverse connection needs of conference and meeting room visitors This sleek elegant ergonomic design features a retractable base station that smoothly rises to expose device connections and recedes back down and conceals the typical cable mess that can distract from the business at hand FIG 1 All this while each cable stays connected HPX 1600 raised HPX 1600 lowered FIG 1 HPX 1600 Retractable Connection Port Common Application Boardrooms conference rooms meeting rooms or auditoriums where equipment is permanently installed in the room and users must connect to that equipment from a co
6. by the top folded tabs falls between the last low voltage secondary circuit module and the first AC Mains Power Outlet 2 Mark the High Voltage Isolator at the point it exits the aluminum chassis 3 Remove the High Voltage Isolator and trim the paper so that it will be flush with the bottom of the chassis upon final installation As an additional reference use the template provided in FIG 32 to trim the High Voltage Isolator to the proper length based on the number and type of AC Mains Power Modules installed 2 US EU AU FIG 32 High Voltage Isolator Trim Template The template assumes that no Stop Block HPX AC SB is used The template is for reference only Verify that the High Voltage Insulation paper is flush with the bottom of the aluminum chassis upon final assembly Step 5 Install AC Mains Power Outlets Reinstall the trimmed High Voltage Isolator trapping the low voltage secondary circuit cables on the sides of the unit as before Install the AC Mains Power Outlets Circuit Breaker Modules and Blank Panel Modules Including Product Label Panels as required Continue with the HPX 1600 installation as described in the accompanying Installation Guide UN VER SITY Increase Your Revenue se ERUS through education knowledge In the ever changing AV industry continual education is key to success AMX University is dedicated to ensuring that you have the opportunity to gather the information and experience you
7. included in the final system require some type of backside termination Refer to the installation guide for each module to determine the required backside termination The backside termination for each module can and should be completed before the module is installed into HPX Base assembly FIG 6 provides two example illustrations of module backside termination Terminating Connections 1 Module Terminating Connections 2 Modules FIG 6 Terminating Connections of 1 or 2 HPX Modules Note that for terminations for which the far end of the cable is not accessible either because the cable has been run under carpet in a conduit or structure or is otherwise fixed the cable must be placed through the retaining ring note the orientation of the retaining ring see FIG 8 on page 11 then through the mounting surface from bottom to top then to the module before the module is placed into the base assembly as shown in FIG 7 FIG 7 Fixed Cable Passing Through Ring Table and Into the HPX 1600 Assembly iii es Note the direction of the screw bosses as indicated in FIG 8 19 0 35 0 iil Mil iit T F Mounting Surface r Retaining Ring ET IN aand Retaining Screw Screw 35 0 note the orientation l of the screw bosses 5 _ Surface Retaining Screw Retaining Screw FIG 8 Direction of the Screw Bosses based on surface thickness 19mm vs gt 19mm thick For mounting surfaces less than 3
8. need to deliver strong AMX solutions Plus AMX courses also help you earn CEDIA NSCA InfoComm and AMX continuing education units CEUs Visit AMX University online for 24 7 365 access to Schedules and registration for any AMX University course Travel and hotel information Your individual certification requirements and progress 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA e 800 222 0193 e 469 624 8000 e 469 624 7153 fax e 800 932 6993 technical support e www amx com 4 12 2012 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time
9. 11 Refer to the Installation Guides provided with each Module for detailed installation instructions Step 5 Install the Bottom Cover Once all of the desired modules are installed complete each face of the system with blank modules At least 3M 3 of blank modules will be used at the bottom of the system to correspond to that portion of the system that is always below the mounting surface even when the system is deployed in the up position FIG 12 The 10A Circuit Breaker provided in HPX PAK xx can be used to occupy one of these positions If a Stop Block FG559 01 is used to limit the travel of the system in the Up position 2M 2 of Blank modules will be used above the Stop Block and below the mounting surface The 10A Circuit Breaker provided in HPX PAK xx can be used to occupy one of these positions li T ril p e a Mounting Surface 10A Circuit Breaker Module Mounting Surface 6 Stop Block x FG559 01 O o Blank Mode s FIG 12 Install Blank Modules at the Bottom of the System Once each face of the system is fully occupied with active or blank modules install the bottom cover 1 Ensure each AC power module is connected to the power inlet assembly and that the circuit breaker is also connected to the power inlet assembly FIG 13 AC Power connector Circuit Breaker Connector Za NES A A ANA 4 DY AC Power connector AC Power connector Bottom
10. 159mm zzin x xxin x yyin of space below the mounting surface e If the system is to be mounted within a column pillar or other enclosed space below the mounting surface please note that final assembly and termination will require the installer to have access to this space below the mounting surface Care should also be taken to ensure that the system does not interfere with the normal use of the work space For example on a table or work surface ensure that the system does not interfere with the user s legs when they are seated at the table Even when the system is deployed in the up position the mounting system and shields occupy the entire space requirement below the table Step 2 Cut the Hole In the Mounting Surface Use the HPX AC TK FG559 90 and a suitable router with 1 2 arbor to create the hole in the mounting surface FIG 4 provides the hole cutout dimensions for reference 4 00 260 0 HYDRAPORT ASSEMBLY FIG 4 Hole Cutout Dimensions 1 Carefully measure the tabletop or other mounting surface to locate the desired position of the Hydraport unit 2 Apply the included double sided tape mounting strips to the bottom surface of the HPX AC T router template making sure that the rounded edges of the mounting strips protrude slightly beyond the edges of the template see FIG 5 3 Use the alignment marks scribed on the template to align the template properly on the mounting surface FIG 5 wa
11. 4 Modula CatPro Series and 8Y 3000 product models will be free of defects in materials and manufacture at the time of sale and will remain in good working order for a period of three 3 years following the date of the original sales invoice from AMX The three year warranty period will be extended to the life of the product Limited Lifetime Warranty if the warranty card is filled out by the dealer and or end user and returned to AMX so that AMX receives it within thirty 30 days of the installation of equipment but no later than six 6 months from original AMX sales invoice date The life of the product extends until five 5 years after AMX ceases manufacturing the product model The Limited Lifetime Warranty applies to products in their original installation only If a product is moved to a different installation the Limited Lifetime Warranty will no longer apply and the product warranty will instead be the three 3 year Limited Warranty All products returned to AMX require a Return Material Authorization RMA number The RMA number is obtained from the AMX RMA Department The RMA number must be clearly marked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its produ
12. 5mm thick orient the screw bosses away form the main assembly down For mounting surfaces greater than 35mm thick orient the screw bosses toward the main assembly up Step 4 Insert the Modules O See Step 4 6 for the installation of High Voltage Isolators HPX PA HVI These Isolators must be installed properly to maintain product safety certifications All Low Voltage Secondary Circuit LWSC Modules must be installed above the AC O Power Outlets and Circuit Breaker Modules in the HPX 1600 Base Assembly The LVSC Modules will therefor be installed first 1 Latch the system in the closed down position 2 Place the HPX 1600 Base assembly upside down on a suitable surface to ensure the top cover is not scratched 3 Remove the four Mounting Screws that secure the Bottom Cover to the aluminum frame and remove the bottom cover FIG 9 4 mounting screws Bottom Cover K 4 gt FIG 9 Installing the Bottom Cover 4 Slide the pre terminate modules one at a time into the Base assembly Note the orientation of each module a small tab exists on the bottom side shown facing up in FIG 10 of the faceplate of each module Ensure this tab is facing the bottom side of the system see FIG 11 on page 14 This tab on each Module faceplate must face the BOTTOM of the Hydraport system detail view of Module Faceplate lt _ HPX 1600 Base Assembly IN shown here upside
13. Required If AC power modules are to be used in International models FG550 BL FG550 SL install a suitable 14AWG power cord into the provided IEC 320 C14 socket North American models FG550 01 BL FG550 01 SL include a pre attached power cord with metal retention bracket If this bracket has been removed during installation reinstall it at this time The metal retention bracket is required to maintain North American Product Safety Certifications Fold the power cord back 180 degrees and secure it to the far side of the bottom cover using the supplied wire ties FIG 21 4 Plastite screws provided AC Power Socket ni FY ZT WS j Y FIG 21 Installing the Power Cord Insure the resulting service loop is tight enough so that it does not rub the shields when the unit moves up and down Step 10 Install Shields 1 Secure the two shields to each other using the 8 supplied screws Ensure that any fixed cables pass through the assembled shield appropriately 2 Snap the assembled shield onto the lower portion of the mounting sleeve 3 Install the four additional mounting screws into the top of the shield to secure the shield to the mounting sleeve FIG 22 of the Shields to the Mounting Sleeve 8 screws 4 on each side _ secure the two Shields to each other FIG 22 Installing the Shields Step 11 Secure Cables Terminate the backside connections as required for each cable exiting bott
14. X 1600 NOTE Install all low voltage secondary circuit modules into the HPX 1600 Hydraport Base Assembly from the bottom of the unit according to the instructions supplied with the HPX 1600 and or low voltage secondary circuit modules For more information refer to the HPX 1600 Operation Reference Guide Position the cables coming from the low voltage secondary circuit modules along the sides of the aluminum chassis These cables will pass along the outside of the folded High Voltage Isolator and exit the unit through the square openings in the bottom cover Step 2 Fold the High Voltage Isolator Use the score lines on the High Voltage Isolator to fold the paper into the shape shown in Figure 1 Interlock the two tabs and slots at the top of the part with the square tab back folded inside the interlocking tabs sides Pre crease the folds as required to achieve a sharp square fold Step 3 Insert the High Voltage Isolator Insert the High Voltage Isolator into the HPX 1600 Base Assembly so that the low voltage secondary circuit cables exiting the chassis are trapped along the sides of the chassis See Figures FIG 30 and FIG 31 l l FIG 30 High Voltage Isolator Installed AC Power wires here Isolator Low Voltage Cables here FIG 31 High Voltage Isolator Cross Section E os E a NOTE Step 4 Mark and Trim High Voltage Isolator 1 Position the High Voltage Isolator so that the partition created
15. conoconos 8 Step 3 Prepare the Terminations netamente tie 10 Step 4 Insert the Modules srt latina 12 Step 5 Install the Bottom Cover issue 15 Step 6 Install the Lift Spring ASSEMONCS escasas irte 18 Step 7 Install the System Into the Mounting Surface oocooccooccnccconoconcconoconccnnoso 20 Step 8 Install the Retaining Ring ssesssssesessssecsssecssssesecssosessoscsecssosessoseoeessoees 21 Step Y Install Power Cord If Required sseeseeseeseoseossossosecsesseoseosesseoseseessessese 23 Step 10 Instal A Mo II e aa 24 Step TT Secure Cables ceiceicesiicscntnseceacecctastesdensbesncsaessasoigetesnestoccmanrentootacceatensnecet 25 HPX P200 xx Power Outlet Module coocooccoccoccnonoccnncnncnnccoccnccnaconcnaconono 27 OV SFO caos 27 Product SPECI CALONS serrin nan E EEE E EEAS 27 Installing the HPX P200 XX Power Outlet Module o ooooooocooccoocncccncconocincnno 28 Disconnect the IEC C 14 Power Inlet Connector On the Hydraport Base Assembly 28 Step 1 Connect the HPX P200 xx to the HPX 1600 Power Inlet Assembly 29 Step 2 Insert the Power Outlet Module Into the HPX 1600 Chassis ooooooooo o 29 Step 3 Install the 10 Amp Circuit Breaker Included with HPX PAK XX Accessory Kit 30 HPX PA HVI High Voltage Isolator ooocooccoccnocnocconcnnccnncnncconcncccccconccnocono 31 A E E 31 Product Specificati ns aaa sriep rsisi senri aias 31 E a T
16. cts or for the failure of its products to perform This includes any lost profits lost savings incidental damages or consequential damages AMX is not liable for any claim made by a third party or by an AMX Autho rized Partner for a third party This Limited Warranty does not apply to a any AMX product that has been modified altered or repaired by an unauthorized agent or improperly transported stored installed used or maintained b damage caused by acts of nature including flood erosion or earth quake c damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance including brownouts sags spikes or power outages or d damage caused by war vandalism theft depletion or obsolescence This limitation of liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the possibility of any such damages This limitation of liability however will not apply to claims for personal injury Some states do not allow a limitation of how long an implied warranty last Some states do not allow the limitation or exclusion of inci dental or consequential damages for consumer products In
17. down as it should be positioned for inserting Modules FIG 10 Inserting Modules Into the HPX 1600 Base Assembly 5 6 Route the cables from each module out the bottom currently facing up of the base assembly If both low voltage secondary circuit LVSC modules and AC Power Outlets will be installed place the LVSC modules in the upper portion of the chassis first followed by the AC Power Outlets in the lower portion of the chassis The LVSC Modules and the AC Power Outlets must be separated by the High Voltage Isolators provided in this kit See the Instructions provided with the High Voltage Isolators for detailed installation instructions For AC power modules plug the provided wire harness into the Power Inlet assembly inside the bottom cover FIG 11 NOTE A ay ae ey a x J Cross section view of Bottom Cover Bottom Cover showing cable routing inside view FIG 11 Bottom Cover Connect each AC power module to the power inlet assembly 8 The included circuit breaker modules should also be connected to the Power Inlet assembly at this time International units FG550 BL FG550 SL include two circuit breakers for line and neutral Both circuit breakers are required for operation Take care while routing the wires to the circuit breaker positioned on the opposite side of the chassis from the two circuit breaker connectors on the Power Inlet assembly see FIG
18. embly FIG 24 HPX P200 xx Hydraport Power Outlet Module HPX P200 US shown O The Hydraport System limits the total available current for all Power Outlet Modules LJ to 10 Amps total NOTE AMX offers four versions of the Hydraport Power Outlet Module all compatible with the HPX 1600 Base Assembly see the Product Specifications section on page 27 Product Specifications HPX P200 XX Specifications e HPX P200 UK 67mm x 65mm x 27mm zzin x xxin x yyin e HPX P200 AU 67mm x52mm x 30mm zzin x xxin x yyin Cable Length All 300mm 12 0in HPX P200 XX Specifications Cont Weight e HPX P200 US 60g 2 12 oz e HPX P200 EU 69g 2 43 oz e HPX P200 UK 74g 2 61 oz e HPX P200 AU 60g 2 12 oz Matt black finished face plate Polycarbonate plastic Rear Connections Three position plug in connector for use with HPX 1600 Hydraport Base Assembly Compatibility e HPX 1600 Hydraport Base Assembly e HPX PAK US Hydraport Power Accessory Kit w US power cord FG559 31 e HPX PAK I Hydraport Power Accessory Kit w no power cord FG559 32 Installing the HPX P200 XX Power Outlet Module Disconnect the IEC C 14 Power Inlet Connector On the Hydraport Base Assembly Ensure that the AC Power cord is disconnected from IEC C 14 power inlet connector on the Hydraport Base Assembly prior to disassembly of the Hydraport Base assembly or installation of the HPX P200 XX Power Outlet CAUTION Module see FIG 25 Pow
19. er Inlet Connector on HPX 1600 AC Power Cord FIG 25 HPX 1600 Power Inlet Cord Removed Step 1 Connect the HPX P200 xx to the HPX 1600 Power Inlet Assembly Plug the 3 Position Connector from the Power Outlet Module into the Power Inlet Assembly located in the bottom cover of the HPX 1600 Base Assembly FIG 26 3 Position Connector from Power Outlet Module HPX 1600 Power Inlet Assembly AC Power connector Bottom Cover j inside view FIG 26 HPX 1600 Bottom Cover Connect Power Outlet Module to Power Inlet Assembly Step 2 Insert the Power Outlet Module Into the HPX 1600 Chassis Insert the HPX P200 XX Power Outlet Module into the main chassis of the HPX 1600 Base Assembly Note the position of module interlock tab this tab should face towards the bottom of the HPX 1600 Base assembly when installed in its mounted position FIG 27 a HPX 1600 Base Assembly bottom Power Outlet Module i i L Module Interlock Tab FIG 27 Inserting the Power Module into the HPX 1600 Chassis Step 3 Install the 10 Amp Circuit Breaker Included with HPX PAK XX Accessory Kit A Hydraport Power Accessory Kit HPX PAK XX is required for the HPX P200 XX Power Outlet Module to be functional This power accessory kit provides a 10 Amp circuit breaker for the Hydraport System to prevent power overload and complete the AC Power Circuit Position the Circuit breaker module included in the HPX PAK XX Power Accessory Kit i
20. erly FIG 16 Clip Base Assembly bottom of HPX 1600 PE AS Sleeve FIG 16 Lift soring assembly clipped to main sleeve 3 Unlatch the sliding frame and mounting sleeve so the sleeve is free to slide relative to the frame 4 Slide the mounting sleeve so that it is nearest to the bottom cover 5 Take hold of the body of one lift spring assembly and pull it firmly up so that it can be snapped into the provided slot in the bottom cover FIG 17 Notch on Lift Spring Assembly The notch on the Lift Spring Assembly fits into the slot on the Bottom Cover Slot on Bottom Cover FIG 17 Inserting the Lift Spring Assembly Into the Bottom Cover 6 Repeat for the second lift spring assembly 7 Slide the mounting sleeve towards the top of the unit until the unit latches in the closed position Step 7 Install the System Into the Mounting Surface Turn the system over and install the unit into the cutout in the mounting surface FIG 18 Mounting Sleeve HPX 1600 Chassis Aluminum Frame bottom FIG 18 Completed Assembly Latched In the Closed Position Make sure that all cables from the backside terminations pass through the cutout Note that any fixed cables should already be passed through both the mounting surface and retaining ring see the Step 3 Prepare the Terminations section on page 10 Step 8 Install the Retaining Ring 1 Insert the four 46 32 x 1 3 8 retaining screws into the retain
21. ing ring Note the orientation of the retaining ring This orientation changes in order to accommodate the various thicknesses of mounting surfaces see FIG 8 on page 11 Note the direction of the screw bosses For mounting surfaces less than 35mm thick orient the screw bosses away form i the main assembly down NOTE For mounting surfaces greater than 35mm thick orient the screw bosses toward the main assembly up 2 Place the retaining ring over the lower portion of the base assembly and against the underside of the mounting surface 3 If an accessory mounting bracket HPX AC MB FG559 21 is to be used install it now by trapping it between the retaining ring and mounting surface FIG 19 HPX AC MB Accessory Mounting Bracket HPX AC MB Accessory Mounting Bracket FIG 19 Installing HPX AC MB Accessory Mounting Brackets 4 Gradually tighten the four retaining screws to secure the unit in the mounting surface Ensure the unit is properly aligned in the mounting surface e Torque the retaining screws to approximately 3 in lbs e Do not over tighten the screws 5 After tightening the retaining screws ensure the unit moves smoothly up and down e Over tightening the retaining screws can cause the system to bind e If the system binds gradually loosen the retaining screws until it operates smoothly FIG 20 on page 22 shows the HPX 1600 Unit installed in to the mounting surface Step 9 Install Power Cord If
22. n the main chassis of Hydraport base assembly such that it resides just below the mounting surface in which the Hydraport system is installed FIG 28 10A Circuit Breaker required included with Hydraport Power Accessory kit HPX PAK XX FIG 28 10A Circuit Breaker Module positioned just below mounting surface level HPX PA HVI High Voltage Isolator D CAUTION D CAUTION Overview The HPX PA HVI High Voltage Isolator FG559 33 is designed to be installed in the HPX 1600 xx xx Hydraport Retractable Connection Port to separate the AC Mains Power from low voltage secondary circuits FIG 29 FIG 29 HPX PA HVI Folded for Installation If AC Mains Power Outlets are to be used in the HPX 1600 this item must be installed in order to maintain Product Safety Certifications Failure to install this item properly may void Product Safety Certifications Product Specifications HPX PA HVI Specifications Vulcanex 6 Vulcanized Fiber Dielectric Strength 300V mil 4 800V Included Accessories Installation Guide Installation Only a professional AMX qualified installer should perform this installation Installation must conform to all local codes This product may not be installed by the end user Tools Required O Scissors Step 1 Install Low Voltage Secondary Circuit Modules O All low voltage secondary circuit modules must be installed above the AC Mains Power Outlets and Circuit Breakers in the HP
23. nference table or lectern The HPX 1600 is designed to be mounted into a horizontal surface such as a conference room table or lectern in order to provide connectivity for power networking Audio Video and control Specific connectivity is accomplished by populating the HPX 1600 Base Assembly with various modules see the Product Specifications section on page 2 for a list of available modules Product Specifications HPX 1600 Specifications Dimensions HWD 9 57 x 10 55 x 4 53 243mm x 268mm x 115mm 15 08 x 11 54 x 6 26 383mm x 293mm x 159mm ron 78h Samm on Weight Base Assembly only 2 Kg 4 41 Ibs Typical Installation 3 Kg 6 61 lbs Models Available e International Black trim FG550 BL e International Silver trim FG550 SL e North American Black trim FG550 01 BL e North American Sliver trim FG550 01 SL Enclosure Natural finish metal frame with plastic top and bottom covers moving ver tically in a plastic sleeve assembly e Matt black top cover and trim ring FG550 BL FG550 01 BL or matt silver top cover and trim ring FG550 SL FG550 01 SL e Matt black module face plates on all I O modules Rear Connections e Included rear connection IEC 320 C14 Power cord receptacle FG550 BL FG550 SL Included AC Power Cord FG 550 01 BL FG550 01 SL e Rear connections for individual modules are routed through openings in the unit s bottom cover Compatibility e HPX P200 US Hydraport Powe
24. ning Ring and 4 Mounting Screws EN Shield and 8 Mounting Screws Shield and 8 Mounting Screws YP Spring Lift Assemblies FIG 2 HPX 1600 Exploded View HPX 1600 Hydraport 6 HPX 1600 Retractable Connection Port Installing the HPX 1600 ATTENTION READ THIS FIRST Installation must conform to all local codes O Only a professional AMX qualified installer should perform this installation This product may not be installed by the end user CAUTION A typical installation will include several of various available modules listed in the Product Specifications section on page 2 Each of these modules has specific instructions for terminating their rear connections Refer to the installation guide for each appropriate module during the installation of the Hydraport system e Read these instructions in their entirety before beginning the installation The installation requires specific steps to be performed the specified order Step 1 Select an Installation Location Note the space requirements for installing the system FIG 3 provides a dimensioned drawing of the HPX 1600 System above and below the table PA A 383 0 9 9 9 9 9 0O 9i 160 0 FIG 3 HPX 1600 Space Requirements 293 0 Oe l Installation Location Notes The Hydraport system requires a mounting surface from 19mm 75in to 50mm 2 0in thick e e The Hydraport system requires at least 383mm x 293mm x
25. om of the HPX 1600 Secure these cables and the power cable to the four tabs provided on the retaining ring using the supplied wire ties FIG 23 Tabs Wire Ties 2 on each side Mounting Surface Retaining Ring sel Shields gt Cables from bottom of HPX 1600 FIG 23 Secured Service Loop Ensure there is sufficient service loop to allow the system to travel in its full range of motion Avoid excess service loop as this can place significant weight on the sliding and lifting mechanism and prevent the system from functioning properly Ensure the service loop does not catch on the shields or any other obstruction and is away from users who might kick or snag the cables e Secure the cables in at least one additional location after they have been secured to the retaining ring so as to prevent undue stress on the system if the cables are inadvertently kicked snagged or pulled Installing the HPX 1600 26 HPX 1600 Retractable Connection Port HPX P200 xx Power Outlet Module Overview The HPX P200 xx Hydraport Power Outlet Module is designed to be used in conjunction with the HPX 1600 Hydraport Base Assembly The HPX P200 XX Power Outlet Assembly provides user accessible AC Mains Power to the front panel of the Hydraport System FIG 24 a ee en ra T z pp EN PE Mi fi f y ji oh gt N p by ch 3 Position Connector EN A lt connects to the HPX 1600 Power Inlet Ass
26. r Outlet Module US FG551 01 e HPX P200 UK Hydraport Power Outlet Module UK FG551 11 e HPX P200 EU Hydraport Power Outlet Module EU FG551 21 e HPX P200 AU Hydraport Power Outlet Module AU FG551 31 e HPX AV100 CS A Hydraport Composite with Stereo Module FG552 10 e HPX AV100 RGB A Hydraport RGBHV with Stereo Module FG552 11 e HPX C5400 CS A Hydraport Composite Stereo UPX CAT5 Kit with HPX carrier FG552 50 BL K e HPX C5400 VGA A Hydraport RGBHV Stereo UPX CAT5 Kit with HPX carrier FG552 51 BL K e HPX C5400 CN A Hydraport Component Stereo UPX CAT5 Kit with HPX carrier FG552 52 BL K e HPX N100 RJ45 Hydraport Single RJ45 Module FG553 01 e HPX N102 RJ45 Hydraport Dual RJ45 Module FG553 02 e HPX N100 USB Hydraport Single USB Module FG553 11 e HPX U100 BTN Hydraport Single Button Module with LED FG554 01 e HPX U400 MET 6N Hydraport Metreau 6N Kit with HPX Carrier FG554 11 BL K e HPX U400 MET 13 Hydraport Metreau 13 Kit with HPX Carrier FG554 12 BL K e HPX U400 MET 7 Hydraport Metreau 7 Kit with HPX Carrier FG554 13 BL K e HPX U400 SP 08 AX Hydraport Novara AxLink 8 button Module FG554 51 BL e HPX U400 CP 1008 Hydraport Novara ControlPad 8 button Module FG554 71 BL e HPX U200 MOD Hydraport Modero Connection Module FG554 81 HPX 1600 Specifications Cont Compatibility Cont e HPX B050 Hydraport Blank Panel 1 2 M Height FG558 01 e HPX B100 Hydrapor
27. such states the limitation or exclusion of the Limited Warranty may not apply This Limited Warranty gives the owner specific legal rights The owner may also have other rights that vary from state to state The owner is advised to consult applicable state laws for full determination of rights EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY AMX MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY EXCEPT AS OTHERWISE LIMITED BY APPLICABLE LAW AMX RESERVES THE RIGHT TO MODIFY OR DISCONTINUE DESIGNS SPECIFICATIONS WARRAN TIES PRICES AND POLICIES WITHOUT NOTICE Table of Contents PP TOOU MIR O a pesenccaueascante san vaneigtacearacsesensas 1 CDV OR WS y ACP POD RE sesame nee nee od peo oweuaecteneperous os cuetenmanesoccuemsaennescnneneneaesueneneeaenenes 1 Common Application rita 1 Product OPecIiHCaHONS suites 2 HPX 1600 Exploded VIS Wi as 4 Installing the APA POO ausencia ladrar 7 ATTENTION READ THIS FIRST its obs ani eeii 7 Step 1 Select an Installation Location rica 7 Installation Location NoteS esseseosesseseoseseosesecseoseseoseoeosesseseosessosesecseosesecseseeseoseososeo 8 Step 2 Cut the Hole In the Mounting Surface coooccocccocccnccnnoccnoconoconoconoconc
28. t Blank Panel 1 M Height FG558 02 e HPX B200 Hydraport Blank Panel 2 M Height FG558 03 e HPX B050 L Hydraport Custom Label Panel 1 2 M Height FG558 11 e HPX B100 L Hydraport Custom Label Panel 1 M Height FG558 12 e HPX AC SB Hydraport Stop Block FG559 01 e HPX AC DA Hydraport Decora Adapter Plate FG559 11 e HPX AC MB Hydraport Accessory Mounting Bracket FG559 21 e HPX PAK US Hydraport Power Accessory Kit w US power cord FG559 31 e HPX PAK I Hydraport Power Accessory Kit w no power cord FG559 32 e HPX AC TK Hydraport Installation Tool Kit FG559 90 Optional Accessories HPX AC TK Hydraport Installation Tool Kit FG559 90 see below HPX AC HSP Hydraport Spring Kit for Heavy Loads FG559 42 Certifications UL 962A N America versions only HPX AC TK Hydraport Installation Tool Kit FG559 90 1 HPX AC TMPLT 559 91 router template Mounting Strips Note The Mounting Strips are manufactured by 3M The 3M part number is 17021P Router bit Freud 12 128 or Whiteside 1072 Guide Bushing Woodcraft 144693 Lock Nut Woodcraft 144696 1 Installation Guide HPX 1600 Exploded View FIG 2 provides an exploded view of the HPX 1600 Hydraport System with the main components referenced in this document labelled Use this diagram for reference while following the instructions provided in this document 4 HPX 1600 Chassis Aluminum Frame Module Faceplates Retai