Home

CyberPower VALUE2200E-GP uninterruptible power supply (UPS)

image

Contents

1. z Load Battery Input Output Run E E N EE a eS OO x S v o E N G a ee i C E ee es ee V x lt tst ie 7 a ie 4th oo oah Sth Retun Xx v x x ooo d Press gt 3sec v y Sound Disable Press gt 3sec again X V X X Sound Enable Overload x VE UT UV Pf X Not Illuminated w a a FF p l i le i x Xx lt x x lt V Illuminated Either For more information visit eu cyberoowersystems com or contact CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 40 2348170 E MAIL sales cyberpower eu com CyberPower Systems Inc USA 4241 12th Avenue East Suite 400 Shakopee MN 55379 U S A Tel 1 952 4039500 Fax 1 952 4030009 E MAIL sales cyberpowersystems com Entire contents copyright 2004 CyberPower Systems B V All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems USA Inc A E amp Pb Free
2. one time PC UPS Communication Protection Ports RJ11 RJ45 Communication protection ports will protect any standard modem fax telephone line or network cable Functional Test TECHNICAL SPECIFICATIONS AC Mode The UPS delivers power to the loads derived from the utility and maintains proper battery charge It also regulates the output voltage to within a narrow range On Battery Mode The UPS operates on battery when the line voltage or frequency has fallen outside the limits Local users are alerted to this mode of operation by visual and audible indicators The UPS provides power to the load from the battery and through its inverter and the output voltage and frequency of the UPS are regulated within a narrow range 1 Switch On Press the power switch on the front panel then the status LCD will light up 2 Switch Off Press again the power switch the status LCD on the front panel will go off 3 Cold Start Start on Battery This UPS can be turned on even when AC is not present Press the power switch on the front panel then the status LCD will light up ROUTINE MAINTENANCE AND STORAGE ROUTINE MAINTENANCE 1 Use dry soft clothes to clean the front panel and plastic parts Do not use any detergent that contains alcoholic ingredient N The expected lifetime of the battery is around 3 years Improper operation and harsh environment will reduce the actual lifetime 3 Unplug the UPS from power inlet if the UPS will not ope
3. SAFETY WARNINGS 7 if Fs Ss SS SS oe 7 as a amp i amp a b b m we tb t gt p ie 7 b ii tog i r 1200E 1500E 2200E User s Manual K01 0000032 01 SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS This equipment can be operated by any individuals with no previous training The socket outlet shall be installed near the equipment and easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary Do not dispose of batteries in a fire the battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following UPS Unit x 1 IEC Power Cord x 1 USB Cable x 1 User Manual x 1 Manageme
4. ct the UPS unit and your computer BASIC OPERATION FRONT PANEL DESCRIPTION Power Switch LCD Function Selected Switch The switch can be used to select the LCD display contents Including input output voltage and estimated run time etc REAR PANEL DESCRIPTION SER zi a fh AC Inlet Connect to utility power through the input power cord Input Circuit Breaker The circuit breaker provides optimal overload protection AC outlet The UPS provides 6 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes Serial Port to PC This port allows connection and communicates from the DB 9 serial on the computer to the UPS unit The UPS communicates its status to E the PowerPanel Personal Edition software This interface is also compatible with the UPS service provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 Windows Vista PLUG IN PC UPS USB Port to PC This port allows connection and communication from the USB port on the computer to the UPS unit The UPS communicates its status to the PowerPanel Personal Edition software This interface is also compatible with the UPS service Ne provided by Windows 98 Windows ME H Windows NT Windows 2000 Windows XP a ne ge Windows Server 2003 Windows Vista gt a NOTE Only one of these two ports can be used as communication and control of the UPS unit at
5. ice cyberpower eu com Connect the serial USB cable to the UPS The serial USB cable is not unit and an open serial port on the back connected of the computer You must use the cable that came with the unit Try another serial USB port of your computer Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit Mechanical problem Circuit breaker is tripped due to overload The serial USB cable is PowerPanel connected to the wrong Personal Edition port is inactive all icons are gray The unit is not providing battery power The serial cable is not the l You must use the cable included with the a was provided with unit for the software CyberPower warrants to you the original purchaser that CyberPower UPS will be free from defects in design assembly materials and workmanship for two years battery is only one year from the date of original purchase Any warranty services please contact your local dealers or distributors Model _s_ is Value 1200E Value 1500E Value 2200E Capacity VA 1200VA 1500VA 2200VA Capacity Watts 720W 900W 1320W Input Input Voltage Range 160VAC 270VAC Frequency Range 50 60Hz 3Hz Auto Sensing Output On Battery Output Voltage On Battery Output Frequency Overload Protection On Utility Circuit Breaker On Battery Internal Current Limiting Physical Total of UPS Receptacles Maximum Dimensions We
6. ight Battery Simulated Sine Wave at 230Vac 7 50 60 Hz 6 IEC 320 C13 32 6cm L X 14 cm W X 18cm H 13 0 kg 28 6 Lbs 14 3 kg 31 5 Lbs 15 4 kg 33 9 Lbs 12V 9Ah x2 Sealed Maintenance Free Lead Acid Battery 12V 7Ah x2 12V 8 5Ah x2 Typical Recharge Time 8 Hours Warning Diagnostics Indicators Power On UPS Status Display Capacity Display Digital Value Display Audible Alarms On Battery Low Battery Overload Environmental Operating Temperature Operating Relative Humidity Communication PowerPanel Personal Edition Software Management Auto Charger Auto Restart USB Yes 32 F to 104 F 0 C to 40 C 0 to 95 NON CONDENSING Windows 98 ME 2000 NT XP Vista DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Indication LOAD BATT CAP INPUT OUTPUT RUN_TIME Sam 00 D EG ox Et Line mode UPS Status Display Capacity Display Digital Value Display Select SW z Load Battery Input Output Run E i EN Ea a a N a Se se es ee eee V V Saaz 1st B oo Po lt 44 ia 5th Return v x J 1 x v x d vy J e e y Press gt 3sec icomdonaey Ye Ye Ie fe fe se Se Le Press gt 3sec again V X X X Sound Enable Overoad v x i v X Not Illuminated lt Me lt V Illuminated Either Battery mode UPS Status Display Capacity Display Digital Value Display Select SW
7. nt software Disk x 1 HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Insure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity 1200VA 720W for Value 1200E 1500VA 900W for Value 1500E 2200VA 1320W for Value 2200E If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the fuse blow If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value TO ESTIMATE POWER REQUIREMENTS Watts W x 1 67 VA or Amps A x 230 VA Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE Before installation please read and understand the following instructions 1 Placement The UPS must be installed in a protected environment away from heat emitting appliances such as a radiato
8. r or heat register Do not install this product where excessive moisture is present L Jk X X Ventilation The location should provide adequate air flow around the UPS with one inch minimum clearance on all sides for proper ventilation Fai O Press the power switch to turn the UPS ON or OFF Charge the Battery Your new UPS may be used immediately upon receipt However charge loss may occur during shipping and storage So charging the battery for at least 8 hours is recommended to insure that the battery is fully charged To recharge the battery simply leave the unit plugged into an AC outlet This UPS can be charged even when UPS is not turn on Connect to AC Use German power cord to connect the UPS to a wall Midi outlet Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at all times a Connect the Load rf bar iit Connect the equipment to your UPS outlets The IEC power cord coming with the unit are used to connect your computer and monitor to the UPS Items such UPS as copiers laser printers vacuums space heaters PC or other large electrical devices SHOULD NOT be connected to the UPS Please make sure that the total loads of your equipments are less than the maximum total power load of your UPS Connect to Computer Install your software and accessories To use the software simply use the enclosed serial interface or USB cable to conne
9. rate for long period of time STORAGE 1 First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected the UPS to avoid battery drain 2 The UPS should be stored in a cool dry location 3 Make sure the battery is fully charged before the UPS is stored 4 For extended storage in moderate climates the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat it every 2 months in high temperature locations TROUBLE SHOOTING Batteries are not fully Recharge the battery by leaving the UPS The UPS does not perform charged plugged in TOE Contact CyberPower Systems at Battery is slightly worn out service cyberpower eu com expected runtime The on off switch is designed to prevent Turn the UPS off Wait 10 seconds and damage by rapidly turning it then turn the UPS on off and on The UPS will not The unit is not connected to The unit must be connected to a turn on an AC outlet 220 240V 50 60Hz outlet i Contact CyberPower Systems at Contact CyberPower Systems at service cyberpower eu com Turn the UPS off and unplug at least one piece connected equipment Unplug the power cord of the UPS then press the circuit breaker knob Outlets do not M eee to Batteries are discharged oe unit to recharge for at least 4 Unit has been damaged by Contact CyberPower Systems at a surge or spike serv