1. APC etric by Schneider SL u Le Installation and Operation AA G Type Rack Power Filter G50NETB2 G50NETB 20A2 120 Vac 15 A 20A General Information Product Features The APC AV G Type GSONETB2 and GSONETB 20A2 Rack Power Filters protect high performance audio and video system equipment from damage due to power surges spikes and lightning strikes You can manage a Rack Power Filter through the display interface Web interface or the command line interface CLI Load and energy monitoring for all connected devices Voltage current and power monitoring Current monitoring for the outlets Three levels of user access accounts Administrator Device User and Read Only User Independent outlet control Configurable power on off delays Event and data logging The event log is accessible by Telnet Secure CoPy SCP File Transfer Protocol FTP serial connection or Web browser using HTTPS access with SSL or using HTTP access The data log is accessible by Web browser SCP or FTP E mail notifications for Rack Power Filter and system events Security protocols for authentication and encryption See the Network Management Card Guide on the enclosed CD for detailed information on how to use the unit and the NMC Inventory av011 a q Power filter User Manual Documentation CD Flashlight 1 1 1 1 G Type Rack Power Filter General Information Safety Electric
2. GREEN FUNCTIONS Utility Rate Enter electrical power utility rate in cents kWh USD only The unit will use this to calculate the savings accumulated when using the green function MASTER and Controlled outlets 12 cents kWh UTILITY RATE Contact Information This screen can be customized to include the contact information of the A V dealer or installer Push the STATUS button to move the cursor to the next letter and use the Up and Down arrow buttons to scroll to the appropriate letter 1 888 882 7228 WWW APCAV COM Maximum and Minimum Voltages Set the voltage range in which the unit should normally operate The unit will protect connected equipment from high and low voltages that are not safe for operation MAX UPPER VOLT 140V 132 140 MIN LOWER VOLT 92V 92 100 10 G Type Rack Power Filter Operation Clear Saved Power Reset the counter for the amount of power that has been saved by the unit YES CLEAR SAVED PWR Language Select the language for the display English French or Spanish Push SETUP to go to the next screen RESET TO DEFAULT MENU LANGUAGE ENGLISH Restore default settings Select YES or NO to restore the default settings YES RESET TO DEFAULT Save screen as default To save a screen as the default push STATUS for three seconds SAVED AS DEFAU
3. even ifthe unit is turned off If utility power is lost and then re applied to the unit the components connected to the UNSWITCHED outlets will turn on immediately and return to the status of operation before the power outage The UNSWITCHED outlets can be turned off through the web interface Delay outlets The unit has five delayed outlets When the unit is turned on power is immediately applied to the SWITCHED outlet power was already being supplied to the ALWAYS ON and UNSWITCHED outlets even though the unit was off Then power is applied to each ofthe DELAYED outlets in sequence DELAY 1 first through DELAY 4 When the unit is turned off power is disconnected from the delayed outlets in reverse order Use the display interface to customize the delay times G Type Rack Power Filter Installation Operation Basic Functions Note The LCD display interface screen and LEDs can be dimmed using the Setup menu Press any button on the front panel of the unit to illuminate the display screen and the LEDs Front panel buttons NFS Dour Utility Source ls Does 122V 60Hz a DELAYA 00000 Use the display interface on the front of the unit to configure and operate the unit Power Push to apply power to the unit or to shut off power to the unit Status Push to display the current status of the unit including the current input output voltage Setup Push to scroll through the
4. the firmware version and the last three faults registered by the unit using the STATUS menus Calculate power savings and money savings Enter your utility rate The G50 unit can calculate the power you save when using the green MASTER and CONTROLLED outlet feature 1 Use the Setup menus scroll to the menu screen Green Function and ensure the function is set to Enable 2 Scroll to the next screen Utility Rate Use the Up and Down arrow keys to enter the rate you pay for electrical power in kWh Note that the unit will only display the savings in dollars but can calculate any currency View energy and money savings Go the Status menu Energy Saved to view the amount of energy saved by the unit Scroll to the next menu Money Saved to view the cost savings Current Sensing outlets The unit can measure the amount of power used by the equipment connected to the delayed outlets G Type Rack Power Filter Operation Lock the unit The unit can be locked to prevent unwanted access To lock or unlock the unit push STATUS and DOWN for three seconds G50NETB2 LOCKED Shut down the unit Push and hold the POWER button POWERING DOWN Display Interface Menus Status menu The Status menu shows the overall status of the unit and of each outlet on the unit Push the STATUS button to move to the next screen Use the arrow keys to scroll up and down Note The menus shown in this manual a
5. LED on the front of the unit will illuminate red if the unit is overloaded Reduce the load by disconnecting one or more components from the back of the unit When the load is below 95 the LED will stop flashing The Wiring OK LED is not illuminated e The wall outlet polarity is reversed The neutral wire is overloaded e The earth ground is not connected at the wall outlet Contact an electrician to inspect the building wiring WARNING Do not operate the unit if any of these conditions exist The unit may not be providing surge protection The unit is on but none of the LEDs are illuminated Push UP or DOWN several times The LEDs should illuminate If they do not illuminate contact APC Technical Support 12 G Type Rack Power Filter Troubleshooting Specifications G50NETB2 G50NETB 20A2 Input Output Input Output Voltage Nominal 120 V Nominal 120 V Input Output Current ISA 20A Frequency 50 60 Hz 50 60 Hz Receptacle Types NEMA 5 15R NEMA 5 20R Number of Outlet Receptacles 9 9 Dimensions HxWxL 4 34 cm x 24 cm x 43 5 4 34 cm x 24 cm x 43 5 1 71 in x 9 45 in 17 13 in 1 71 in x 9 45 in 17 13 in Power Cord 2 4 m 8 ft right angle 2 4 m 8 ft right angle NEMA 5 15P NEMA 5 20P Utility Surge Performance EMI RFI Filtering 50 db 150 kHz to 1 MHz 50 db 150 kHz to 1 MHz 40 dB to 30 MHz 40 dB to 30 MHz Environmen
6. SWITCHED 6 G Type Rack Power Filter Operation av016 a Configure the Unit Set the Language Select a language Push the SETUP button until the Language menu is displayed Select English French or Spanish Configure the brightness of the display To alter the brightness of the LCD display screen push SETUP one time and select a desired brightness level Sequence Delay outlets Configure the delay options so that the DELAY outlets apply power in sequence instead of all at one time Push SETUP until the delay menu screen appears Use the UP and DOWN buttons to change the number of seconds of delay When finished push SETUP again to move to the next delay screen Configure Master and Controlled outlets Enable and Disable the Power Saving feature Use the Setup menus and navigate to Green Functions to enable or disable the feature Setting the threshold The amount of power used by a device in Sleep or Standby mode varies between devices It may be necessary to adjust the threshold at which the MASTER outlet signals the CONTROLLED outlets to shut down Use the Setup menus and navigate to Power Threshold to change the power threshold of the master outlet View status of the unit Push the STATUS button until the input source voltage and frequency screen appears Push the STATUS button to display the output current and percentage You can also view APC Technical Support contact information the model and serial number of the unit
7. at least five hours before initial use G Type Rack Power Filter General Information av012a av005a N Installation Install the Unit Install the unit on a flat surface Remove the mounting brackets Q CSS SS E av014 a Attach the stabilizing feet Attach the stabilizing feet included to the bottom of the unit before placing it on a flat surface to avoid scratching the surface and to protect the unit av015 a ump nf T S t 4a at Install the unit in a rack or enclosure Use four screws to secure the mounting brackets to the rails in the rack or enclosure Connect Utility Power Connect the unit to utility power Note If the unit is connected to utility power the unit is actively monitoring input power but is operating in Standby mode Use the utility power cord to connect the unit to utility power If the unit is functioning properly the display will illuminate G Type Rack Power Filter Installation Connect Components to the Unit Power Saving Master and Controlled outlets The unit reduces power consumption by disconnecting utility power to devices that are not in use When a device is in sleep or standby mode it still uses power when the unit turns off the power to an outlet it conserves this power 1 Before connecting components to the unit determine which components will utilize the Master and Controlled outlets Connect a master device such as a TV to the Master out
8. manual are for reference only Information displayed on the unit may be different than shown here LCD dimmer Set the brightness of the display DISPLAY DIMMER NORMAL G Type Rack Power Filter Operation LED dimmer Set the brightness of the LEDs DIM1 LED DIMMER Delay1 Delay4 Select the number of seconds for the delay for DELAY outlets 1 2A 2B 3 and 4 4SEC 0 255 DELAY 1 Power Threshold The amount of power used by a device in Sleep or Standby mode varies between devices It may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down 1 Ensure a master device is connected to the Master outlet Put that device into Sleep or Standby mode or turn it OFF 2 Press STATUS and hold for three seconds 3 The G50 will now recognize the standby power threshold of the Master device and save it as the new threshold setting Use the UP or DOWN arrow key to adjust the power threshold 10 W 10 85 POWER THRESHOLD Green Function Use the Up and Down arrow buttons to enable or disable the Green Function The Green Function allows you to utilize the MASTER and CONTROLLED outlets When the device plugged into the MASTER outlet goes into Sleep or Standby mode or turns off the equipment that is connected to the CONTROLLED outlets will also turn off saving electricity DISABLE
9. setup menus Up Down Push to change values Setup menu and browse menu pages Status menu Display interface LEDs There are eleven LEDs on the display interface LED Illuminated Not Illuminated POWER ON The unit is supplied with utility There is no input utility power power LINE OK The utility power is within The input voltage from utility power is outside the acceptable range 92 V to 140 V acceptable range and the unit has disconnected from utility power to protect the connected equipment PROTECTION The unit is protecting all connected The unit is not providing power protection See WORKING equipment Troubleshooting and contact APC Technical Support immediately WIRING OK The unit is functioning properly There is a problem with the building wiring Contact a certified electrician OVERLOAD The unit is overloaded Disconnect The unit is functioning properly some connected components Contact APC Technical Support DELAY 1 Power is being supplied to DELAY1 Power is not being supplied to DELAY1 DELAY 2A Power is being supplied to Power is not being supplied to DELAY2A DELAY2A DELAY 2B Power is being supplied to Power is not being supplied to DELAY2B DELAY2B DELAY 3 Power is being supplied to DELAY3 Power is not being supplied to DELAY3 DELAY 4 Power is being supplied to DELAY4 Power is not being supplied to DELAY4 SWITCHED Power is being supplied to Power is not being supplied to SWITCHED
10. LT THIS SCREEN IS G Type Rack Power Filter Operation Troubleshooting The unit will not turn on There is no input power or insufficient input power from the wall outlet Use a voltmeter to check the output ofthe wall outlet Use a device that is known to work properly to check the outlet Note The unit will not turn on if the input utility power is out of the acceptable range A circuit breaker has been tripped e Check the building circuit breakers and the unit s circuit breaker If the circuit breaker on the unit has been tripped the center post will protrude from the unit To reset the breaker push the center post into the unit If it trips again unplug one of the components plugged into the unit and reset the breaker GSONETB2 is rated for 15 Amps GSONETB 20A2 is rated for 20 Amps however the National Electric Code NEC dictates that any home circuit should not be loaded to more than 80 of its rating Note If the breaker is tripped again after trying this solution contact APC Technical Support Power is not supplied to some outlets Power to the CONTROLLED outlets has intentionally been turned off The CONTROLLED outlets are not supplying power even though the master device is not in sleep mode The MASTER Outlet threshold may be incorrectly set The Overload LED is illuminated The unit is overloaded The Overload LED is flashing The Overload
11. al Hazard For indoor use only e Risk of electric shock Do not plug into another relocatable power tap Contains always on receptacles To reduce the risk of electric shock disconnect the unit from the power source before servicing the equipment e Overloading Do not overload the wall outlet where this device is being connected Do not overload this device Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual Power Ensure this device is connected to a properly grounded AC power source Further ensure the device is plugged into a source providing the required 120 Vac Do not use a plug adapter which defeats the ground pin of the AC plug e Placement Do not install this device on any unsteady surface Do not install this device on any heat source e Water and Moisture Do not use this product near any source of water or in an environment where the relative humidity may exceed 95 non condensing e Polarization This device has a polarized AC line plug having one grounding pin This plug will only fit into the wall outlet in one orientation This is a safety feature Do not remove the round grounding pin System Ground Terminal The unit provides for the connection of grounding wires from all of your equipment to a central terminal lug This ground connection eliminates ground loop problems tie all component grounds to this screw to break any possible ground loop
12. let Connect peripheral devices such as amplifiers DVD players or sub woofers to the Controlled outlets 2 Connect components to the outlets on the back panel of the unit 3 Configure the unit to recognize the master outlet See Configure Master and Controlled outlets on page 7 Always On Unswitched Switched and Delayed outlets Before connecting components to the unit determine which components will utilize the ALWAYS ON outlets the UNSWITCHED outlet the SWITCHED outlet and the DELAY outlets Then connect components to the appropriate outlets The outlet on the front panel is the ALWAYS ON outlet The two UNSWITCHED outlets are on the rear panel of the unit Always On outlet The ALWAYS ON outlet supply power to the connected components even if the unit is turned off If utility power is lost and then re applied to the unit the component connected to the ALWAYS ON outlet will turn on immediately and return to the status of operation before the power outage Switched outlet The SWITCHED outlet supplies power to the connected equipment while the unit is on If the unit shuts off it will not supply power to equipment connected to the SWITCHED outlet If utility power is lost and then re applied to the unit equipment connected to the SWITCHED outlet will turn on immediately and return to the status of operation before the power outage Unswitched outlets The UNSWITCHED outlets supply power to the connected components
13. re for reference only Information displayed on the unit may be different than shown here Utility Source Voltage and Frequency 120V 60Hz UTILITY SOURCE Total Output 12A 60 1440 W TOTAL OUTPUT Delay Output The next screens will show the output from each of the DELAY outlets DELAY1 DELAY2A DELAY2B DELAY3 and DELAY4 3 0A 360W DELAY1 OUTPUT Unswitched ON ON Unswitched Energy Saved 5 0 KWH ENERGY SAVED 8 G Type Rack Power Filter Operation Money Saved MONEY SAVED 12 40 Dollars IP address IP address 10 177 56 6 MAC address MAC address 00C0B752B77 Contact Information 1 888 882 7228 WWW APCAV COM Model and Serial Number G50NETB2 SN AB1234567890 Firmware version FW REVISION 880 Mla D Recent Faults The screen will either display No fault or it will report any recent faults on the unit and give a brief description Contact APC AV Customer support NO FAULT Description FAULT CONDITION Setup menu Use the Setup menus to configure the unit There are nine setup menus Push the SETUP button to move to the next screen Use the arrow keys to scroll up and down Note The menus shown in this
14. rt Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC Knowledge Base and using e support e Contact the APC Customer Support Center by telephone or e mail Local country specific centers go to www apc com support contact for contact information For information on how to obtain local customer support contact the APC representative or other distributors from whom you purchased your APC product O 2011 APC by Schneider Electric APC and the APC logo are owned by Schneider Electric Industries S A S American Power Conversion Corporation or their affiliated companies All other trademarks are property of their respective owners 990 4316B 4 2011
15. s that can cause an audible noise e Servicing There are no user serviceable components within this device Removal of the cover from this device may present a shock hazard and or void the warranty Damage Requiring Service If any type of damage occurs to this device immediately disconnect it from the wall outlet Notify APC Technical Support or Customer Service at once e CAUTION Do not install this device if there is not at least 10 meters 30 feet or more of wire between the electrical outlet and the electrical service panel G Type Rack Power Filter General Information Components Front view A g gt Circuit breaker O Power button O LCD Display O SETUP button ALWAYS ON outlet STATUS button Down button 11 display interface LEDs vp button Removable flashlight Rear view ati ALA O Network port O Serial port CAN BUS In port CAN BUS Out port 6 System Ground UNSWITCHED outlets O SWITCHED outlet O MASTER outlet DELAY1 outlet O CONTROLLED outlets DELAY 2 A amp B outlets CONTROLLED outlets DELAY 3 outlet CONTROLLED outlets DELAY 4 outlet Removable Flashlight The removable flashlight can be replaced contact APC to order a replacement Note Charge the flashlight for
16. tal Performance Specifications Operating temperature 0 40 C 32 104 F 0 40 C 32 104 F Storage temperature 15 45 C 5 113 F 15 45 C 5 113 F Net weight 4 4 kg 9 7 lbs 4 6 kg 10 1 Ibs Relative Humidity 0 95 non condensing 0 95 non condensing Safety Agency Approval UL1449 UL1363 cETLus Listed FCC Part 15 Class B Contact Information www apcav com or 1 888 88APCAV Contact APC Technical Support For technical support go to www apcav com or call 1 888 88APCAV 1 888 882 7228 Warranty APC warrants the GSONETB2 and the GSONETB 20A2 excluding the removable flashlight to be free from defects in materials and workmanship under normal use and service for the lifetime of the original purchaser APC warrants the removable flashlight to be free from defects in materials and workmanship under normal use and service for one year from the date of purchase APC s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from APC or an APC Service Center with transportation charges prepaid and must be accompanied by a brief description of the problem and proof of date and place of purchase This warranty applies only to the original purchaser G Type Rack Power Filter Specifications 13 APC Worldwide Customer Suppo