Home

AMX MVP-WDS-9

image

Contents

1. af EFA Overview While charging the MVP 9000i the Power over Ethernet MVP WDS 9 Wall Flush Mount Docking Station provides fast reliable wired Ethernet communication to the touch panel In addition the MVP WDS 9 employs a unique anti theft locking mechanism to keep the touch panel safe and secure With a push of a button the panel glides forward for simple removal and transport The Wall Flush Docking Station is available in either white FG5967 13 or black FG5967 12 MVP WDS 9 MVP 9000i GB ecurity Release button FIG 1 MVP WDS 9 GB Wall Docking Station Front The features of the MVP WDS 9 include e Touch panel password feature for security e Integrated docking alignment guides for easy docking Specifications MVP WDS 9 Specifications Dimensions HWD 9 75 x 12 50 x 2 13 24 77cm x 31 75cm x 5 40cm Note Always use the cutout installation dimensions for the MVP WDS 9 when installing this unit into various surfaces A cutout template is included with the device for ease of installation Power e 30 W Class II listed power supplemented supplied via Requirements the PS POE AT High Power PoE Injector Startup Power e Cradle and panel not charging 16 W Requirements e Cradle and panel charging 23 W e Ejection 23 W e Without back box 1 50 Ibs 0 68 kg e With back box 2 40 lbs 1 09 kg Front Panel e Securing Magnets Secures MVP touch panel during Components ejection e Security
2. Ferrite installation position Recommended Ethernet cable path FIG 3 Back of MVP WDS 9 Wall Docking Station 2 Select the knockout to be removed from the top of the back box The box has two pairs of knockouts at the top left and the top right FIG 3 Note To assist with wiring and to avoid mechanical stresses on the wire and the mechanism of the Wall Docking Station the top left knockout when viewing the device from the rear is preferred for use for Ethernet installation Use the top right knockout for USB cable connection 3 Connect the PS POE AT High Power PoE Injector to a power source Connect the PS POE AT to an Ethernet switch on the network via one length of Ethernet cable and insert one length of Ethernet cable for connection to the Wall Docking Station For full warranty information refer to the AMX Instruction Manual s associated with your Product s 11 11 2011 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com 4 Run the Ethernet cable through the knockout into the back box Pull out about six inches 15 25cm of cable into the back box to facilitate installation of the MVP WDS 9 5 Slide the plastic back box into the hole being careful not to twist or pinch the cable and
3. taken to ensure its proper installation to prevent potential damage to the MVP 9000i placed within The device may be installed into existing walls but the optional metal rough in box must be installed before installation of drywall or other paneling Note Other than wall installation tools the only tool required for this installation is a 2 Phillips screwdriver Installing the Wall Docking Station and Plastic Back Box The Plastic Back Box has two pairs of knockouts at the top of the box and four 4 lockdown wings attached to the box with Phillips head screws For ease of installation the interior of the box contains an UP arrow pointing to the knockouts Note The optional CB MVP WDS9 Metal Rough In Box is not required for installation of the supplied Plastic Back Box but it offers an extra level of support To install the Plastic Back Box 1 Cuta hole into the wall or surface intended to hold the back box The back box is sized 12 1 16 inches 30 64 cm long and 8 11 16 inches 22 07 cm high Use the included MVP WDS 9 Wall Docking Station Template 68 5967 01 as an aid for hole placement and measurement WARNING Make sure to measure the size of the intended hole before starting to cut it Cutting the hole slightly smaller than the dimensions to allow for adjustments is highly recommended Recommended USB installation 5n Recommended Ethernet installation Knockout placemen in back box Ethernet port
4. DS 9 GB Black FG5967 10 MVP TDS 9 GW White FG5967 11 CB MVP WDS9 Rough In Box FG038 13 The MVP 9000i panel remains locked in the MVP WDS 9 until unlocked by the user This may be done by pressing the Security Release button and then entering an appropriate password please refer to the MVP 9000i Operation Reference Guide available from www amx com for more information The station ejects the MVP 9000i device top first FIG 2 The device uses two neodymium rare earth magnets to secure the MVP 9000i to the cradle when the touch panel is angled forward Wall Docking Station MVP 9000i Security Release button FIG 2 MVP WDS 9 GB Wall Docking Station Side View Unlocking the Touch Panel Once placed within the Wall Docking Station the MVP 9000i remains secured until the user unlocks it To release the touch panel from the Wall Docking Station 1 Press the Security Release button 2 A password keypad will pop up on the MVP 9000i screen Enter a password in the password keypad and press Enter 3 Wait for the Wall Docking Station to pivot the touch panel away from the wall 4 The device will remain in the ejected position until the MVP 9000i is removed Wait until the device s ejection door has completely withdrawn before re installing the MVP 9000i Recharging To recharge the MVP 9000i 1 Slide the device into the Wall Docking Station cradle bottom first and make sure the device is fully seated in the Do
5. Latch Adds the primary layer of security when mounting an MVP touch panel When the device is inserted this latch grabs onto the rear of the touch panel and secures it to prevent it from inadvertently being removed e Interface Connector A set of contacts that connect to the underside MVP connector strip This connection provides both communication and power between the touch panel and the MVP WDS 9 e Support Cradle This retractable mechanism supports a resting MVP panel and allows a user to either insert or remove a connected MVP panel e Security Release pushbutton Located on the front of the unit this pushbutton toggles an on screen security keypad if security is enabled Entering the correct release code allows the MVP WDS 9 to release the touch panel from the security latch e Operating Temperature 0 C 82 F to 40 C 104 F e Battery Charging Temperature 0 C 32 F to 30 C 86 F e Operating amp Battery Charging Humidity 20 to 85 RH e Storage Temperature 10 C 14 F to 60 C 140 F e Storage Humidity 5 85 RH Operating Storage Environments Installation Guide MVP WDS 9 wall Flush Docking Station MVP WDS 9 Specifications Cont Snap On Ferrite 04 0007 MVP WDS 9 Wall Docking Station Template 68 5967 01 PS POE AT High Power PoE Injector FG423 81 Included Accessories Other AMX Equipment MVP 9000i GB Black FG5967 01 MVP 9000i GW White FG5967 02 MVP T
6. cking Station 2 Press the top of the MVP 9000i back until it clicks The touch panel is now locked into the Docking Station and the station will automatically charge the device s battery 3 To release the touch panel press the Security Release button enter the password if activated and wait for the Wall Docking Station to pivot the touch panel away from the wall Note Charging Lithium Polymer batteries at high temperature will reduce the battery life Industry guidelines dictate that batteries should not be charged at temperatures above 45 C 113 F The temperature is determined by a combination of the ambient temperature where the panel is located plus temperature increases normally occurring inside electronic devices containing batteries AMX has implemented battery temperature monitoring features to maximize the rate of battery charging while staying within industry temperature guidelines Battery charge times will increase in installations where the room temperature is above 25 C 77 F and may be temporarily suspended at room temperatures above 30 C 86 F Battery charging will automatically resume once the temperature has fallen to appropriate levels Minimizing the display backlight intensity and turning off the backlight during periods of non use will also yield faster charge times Installing the MVP WDS 9 Since the Wall Docking Station is intended to be affixed to a wall or other permanent structure care must be
7. e MVP WDS 9 Installation Kit into the screw holes in the interior compartment of the device and tighten them to anchor the device to the back box Note For ease of installation put each screw on a neodymium magnet in the device s interior compartment to keep them on hand until they are needed 10 Take a rubber pad and remove its adhesive backing Put the foot adhe sive side down in the slot surrounding the screw hole in the Wall Docking Station Press down firmly to remove any air bubbles from underneath the foot 11 Install an MVP 9000i device by placing it into the interior compartment bottom first Press the top of the touch panel until it is flush with the Wall Docking Station The neodymium magnets will hold it in place 12 To remove the MVP 9000i press the Security Release button and wait for the touch panel to pull away from the Wall Docking Station Once it has been released grip it by the top of the device and pull it free from the Docking Station For additional installation information please refer to the MVP 9000i Modero ViewPoint Touch Panel Operation Reference Guide available online at www amx com 93 5967 12 REV E UNA BS e i
8. set it flush with the wall Make sure that all of the lockdown wings are folded into their slots before attempting to insert the box For ease of installation the inside of the box has the direction UP labeled for reference 6 Extend the wings on the sides of the back box by tightening the screws inside the box taking care not to overtighten Not all of the wings must be extended to lock the back box in place but extending a minimum of two wings on opposite sides of the box is required Apply enough pressure to the screw head to keep the box flush with the wall this ensures that the wing will tighten up against the inside of the wall WARNING Make absolutely certain that the back box is in its intended position Once the back box lockdown wings are extended removing the back box will be extremely difficult without damaging the wall in the process Note The maximum recommended torque to screw in the wings on the plastic back box is 5 IN IBS 5 NI CM Applying excessive torque while tightening the wing screws such as with powered screwdrivers can strip out the wings or damage the plastic back box 7 Attach the included snap on ferrite to the Ethernet cable as close to the RJ 45 connector as possible Attach the cable to the Ethernet Port FIG 3 8 Firmly seat the device against the back box Make sure that the tab connectors at the bottom of the device are locked into the back box 9 Insert the two installation screws from th

Download Pdf Manuals

image

Related Search

Related Contents

LEDS-13902NX-LJ9  藍:0570一08。一ー 。。 受付時間=平日9=00~ーフ=00  Pioneer DEH-4200SD Car Radio OWNER`S MANUAL Operating  SAVe TheSe inSTruCTionS iMPorTAnT SAFeTY inSTruCTionS  DMX 512 MASTER  Mode d`emploi Systèmes de sécurité avec verrouillage ESL-IH-AR  multimedia 2006 software user manual(19.2).cdr  Manual de segurança  Whistler RLC-100 User's Manual  LC87BK00 SERIES USER`S MANUAL  