Home
Bogen NR100
Contents
1. 12 2008 BOGERI COMMUNICATIONS INC 50 Spring Street Ramsey NJ 07446 U S A Tel 201 934 8500 Fax 201 934 9832 www bogen com
2. COMPLIES WITH PART 68 FCC RULES FCC REGISTRATION NUMBER CD23CH 17566 KX N RINGER EQUIVALENCE 1 1 B NR 100 NIGHT RINGER TEL CONTACT POWER BGM RING RING SUPPLY SOURCE INPUT TORCA B 24 A A BS ASB Bees eesree NR100 Night Ringer Installation amp Use Manual BOGERI COMMUNICATIONS INC 2009 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5883 02B 0911 THE FOLLOWING INFORMATION IS REQUIRED BY PART 68 OF FCC RULES TO BE SUPPLIED TO THE PURCHASER OF REGISTERED EQUIPMENT This equipment complies with part 68 of FCC rules The FCC registration number and ringer equivalence num ber are printed on the front panel of this equipment You must upon request provide this information to your tele phone company If this equipment causes harm to the telephone network the telephone company may discontinue your service temporarily If possible they will notify you in advance If advance notice is not practical you will be notified as soon as possible You will be notified of your right to file a complaint with the FCC The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning The telephone company may make changes in its facilities equipment operations or procedures that could af fect the proper functioning of your equipment If so you will be n
3. Connects to 24V DC supply capable of supplying 25mA 24 amp 24 Bogen PRS2403 Power Supply is recommended Connect power supply only as shown in Figures 1 or 2 Do not ground either of the power supply terminals Be sure to observe correct polarity BGM SOURCE Connects to background music source This input is muted A amp B upon activation of the NR100 AMP INPUT Output terminals to the paging system These terminals are A amp B connected to the MUSIC AUX input Fig 1 NR100 Single Line NR100 Connection TEL CONTACT POWER BGM AMP RING RING SUPPLY SOURCE INPUT T R A B i2V 27 A BAB QDODAOPPAAPP TO C O TO BGM INPUT LINE OF PAGING SYSTEM TO BGM SOURCE F POWER suPPLy 24V Fig 2 NR100 Multi Line NR100 Connection TEL CONTACT POWER BGM AMP MULTI LINE RING RING SUPPLY SOURCE INPUT RINGING T R A B a2 27 A BOA OB ADAPTER C O LINE 1 2222202222 gp TOBOMINPUT OF PAGING SYSTEM C O LINE 2 TO BGM SOURCE POWER suPPLy 24V C O LINE 3 Specifications Registration No under Part 68 of FCC Rules CD23CH 17566 KX N Ringer Equivalency 1 1B Power Requirements Voltage 24V DC Current 25 mA Inputs Terminal Strip Power Supply 24 24 TEL RING T R CONTACT RING A B BGM SOURCE A B Output Terminals AMP INPUT A B Maximum Tone Output Signal 20dBm 77mV into 600 ohms Controls TONE Volume Ringer Tone Dual frequency warble Operating
4. Temperature Range 32 122 degrees F 0 50 degrees C Enclosure Steel finished in black enamel Dimensions 5 1 4 W x 3 H x 1 1 4 D Weight 11b Service CAUTION There are no user serviceable parts within the NR100 Removal of the cover can void the warranty All repairs should be performed by the Bogen service department or an authorized repair agency Limited Warranty Exclusion of Certain Damages The Bogen NR100 Night Ringer is warranted to be free from defects in material and workmanship for two 2 years from the date of sale to the original purchaser Any part of the product covered by this warranty that with normal installation and use becomes defective as confirmed by Bogen upon inspection during the applicable warranty period will be repaired or replaced by Bogen at Bogen s option provided the product is shipped insured and prepaid to Bogen Factory Service Department 50 Spring Street Ramsey NJ 07446 USA Repaired or replacement product will be returned to you freight prepaid This warranty does not extend to any of our products that have been subjected to abuse misuse improper storage neglect accident improper installation or have been modified or repaired or altered in any manner whatsoever or where the serial number or date code has been removed or defaced THE FOREGOING LIMITED WARRANTY IS BOGEN S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER S SOLE AND EXCLUSIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF AN
5. Y KIND EITHER EXPRESS OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product INNO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF THE MANUFACTURE SALE OR SUPPLYING OF PRODUCTS EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from State to State Products that are out of warranty will also be repaired by the Bogen Factory Service Department same address as above or call 201 934 8500 The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department All shipping charges in addition to parts and labor charges will be at the owner s expense All returns require a Return Authorization number For most efficient warranty or repair service please include a description of the failure
6. otified in advance to give you an opportunity to maintain uninterrupted telephone service Note that for all applications of this equipment coin service lines and party lines may not be used This equipment is typically used as an adjunct device to other registered equipment i e PABX 1A2 Key or Elec tronic Key System Such host equipment may be leased If so permission of the owner should be obtained prior to the installation of this equipment If you experience trouble with this equipment please contact the Service Department of Bogen Communica tions Inc at 50 Spring Street Ramsey New Jersey 07446 telephone 201 934 8500 Information will be pro vided on how to obtain service or repairs The Bogen Model NR100 produces an electronic ringing tone over the loudspeakers of a paging background music system The device may be activated by a ring signal from a sin gle telephone or from a contact closure supplied by a suitable telephone interface device The NR100 is generally connected to the background music input of a paging amplifier and the background music source connected to the NR100 This arrangement permits muting of the background music source during the ring signal On amplifiers with paging priority the night ringer tone has priority over background music and paging has priority over both The NR100 is ruggedly constructed to be maintenance free It operates from a 24 volt DC source Bogen Model PRS2403 power sup
7. ply recommended and includes flanges for wall mounted installation Use suitable fasteners when mounting to a wall or backboard Unpacking The NR100 was carefully checked before leaving the factory Inspect it and the shipping container for damage Report damage to the distributor who supplied the equipment If the unit was shipped to you notify the transportation company and file a claim Installation For single line connection connect the unit as shown in Figure 1 Use Figure 2 for multi line connection Note the following installation precautions 1 Connect either the TEL RING or CONTACT RING terminals to the telephone system as shown in Figures 1 or 2 Note Do not use both types of ring inputs on the same device 2 Connect the background music source to the BGM SOURCE A amp B terminals Connect the shield from the BGM source to the same letter A or B terminal as the shield for the amplifier input to the AMP A amp B terminals If the amplifier input is balanced this precau tion is not necessary Following installation test ring the unit and set the TONE volume control to achieve an acceptable level This control is screwdriver adjustable Terminal Connections TEL RING T amp R Connects to telephone line and activates the NR100 upon detection of a telephone ring signal CONTACT Activates the NR100 when shorted through a normally open RING A amp B dry contact requires suitable multi line interface POWER SUPPLY
Download Pdf Manuals
Related Search
Related Contents
Oxford® Cuisinart CEG-980T Electric Grill User Manual C O M M A N D E R XM-L USER MANUAL User Manual - Gill Instruments StarTech.com 40 ft DVI-D Dual Link Cable - M/M MELSEC-Q/L Ethernet Interface Module User`s Manual (Application) Triarch 32733 User's Manual V670 Series User`s Manual - Products Copyright © All rights reserved.