Home

Bosch DWB09E750 cooker hood

image

Contents

1. Extractor hood en Instructions for installation and use 2 Table of contents INSTRUCTION MANUAL u2u222220000a00000nnn0nnnnnnn nn nnunnnnnnn nn nun 2 Environmental WIV O USC HOM ctisssr gins ition celiac honest ctetetusrmacta cid iaicincartaindel 2 Safety INSirWelloNs una 2 Operating modes ie netten 4 Exhaust all NO nee ee 4 Circulating air MOdE ans eenene 4 GT AUN ON einen 4 Installing and removing filter uunuuuuunnnnennnnnnnnnnnnnnnnnnnnnnne 5 Cleaning and Caressa 5 Replacing bulbSs 4 04R nee este anne ern 6 INSTRUCTION MANUAL Additional information on products accessories replacement parts and services can be found at www bosch home com and in the online shop www bosch eshop com Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice GB 0844 8928979 Calls from a BT landline will be charged at up to 3 pence per minute A call set up fee of up to 6 pence may apply IE 01450 2655 Trust the expertise of the manufacturer and rest assured that the repair will be carried out by trained service technicians using original spare parts for your domestic appliance A Safety instructions General information Follow these instructions in particular the safety instructions The appliance can only be used safely if it is correctly installed according to the safety instructions Retain the instructions for sub
2. 120 mm 1 Attach reducing connector directly to the air pipe connector 2 Attach exhaust air pipe to the reducing connector 3 Seal both joints appropriately Electrical connection IN Risk of electric shock from damaged connection cable Do not kink or pinch connection cable during installation The required connection data can be found on the rating plate inside the appliance to do this remove the metal mesh grease filter Length of the connection cable approx 1 30 m This appliance complies with the EC interference suppression regulations This appliance may be connected to a correctly installed earthed socket only Attach the earthed socket preferably inside the flue duct m Ihe earthed socket should be connected via its own circuit m f the earthed socket is no longer accessible following installation of the appliance a disconnector must be fitted as for a permanent connection lf a permanent connection is required the installation must feature an all pole disconnector circuit breakers fuses and contactors with a min 3 mm contact opening The permanent connection may be installed by an electrician only Attaching flue duct IN Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance max 954 mm 1 Separate the flue ducts To do this remove the adhesive tape 10 2 Remove the protective foil from both flue ducts 3 Push on
3. 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall 210 300 mm 51 5 66 92 Installation 1 Screw on the fixing bracket for the flue duct Qe 2X 2 Screw on brackets for the extractor hood hand tight max 3 Nm E A KAG Securing the appliance 1 Press the safety caps with the arrow upwards onto 3 Screw in threaded pin leaving it protruding out of the wall the brackets until they engage by 5 9 mm 2 Screw on knurled nut and washer firmly amp u min 5 mm max 9 mm CC KE Attaching and aligning the appliance Removing safety caps 1 Initially remove the protective foil from the back If the safety caps have to be removed use a flat screwdriver of the appliance and following installation remove foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets BJ 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Connecting the pipes Note If using an aluminium pipe smooth the connection area beforehand Exhaust air pipe 150 mm recommended size Attach exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe
4. A damaged connection cable must be replaced by a qualified technician electrician Risk of burns risk of electric shock from defective bulbs Switch off fuse or pull out mains plug Always replace defective bulbs immediately leave bulbs to cool down first to prevent the remaining bulbs from overloading Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system I gt a W amp Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances m Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible Operation These instructions apply to several appliance models It is possible that individual features are described which do not apply to your appliance Note Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Control panel variant 1 Display fan settings 0 0801 A S Reduce fan speed Increase fan speed Intensive setting Light On Off Control panel variant 2 Light On Off Fan setting
5. ace with bulb of the same type 3 Insert bulb cover 4 Insert mains plug or switch on fuse again LED lights Defective LED lights may be replaced by the manufacturer his customer service or a qualified technician electrician only IN Risk of injury due to LED lights of risk group 1 Do not look directly into the switched on LED lights for longer than 100 seconds INSTALLATION INSTRUCTIONS electro Safety notes A Mortal danger risk of intoxication Due to combustion gases sucked back in Never operate the appliance in the exhaust air mode at the same time as a room air dependent heat producing appliance unless an adequate Supply of fresh air is ensured Room air dependent heat producing appliances e g gas oll wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air is extracted from the kitchen and neighbouring rooms a partial vacuum is produced if not enough fresh air is supplied Toxic gases from the chimney or the extraction shaft are sucked backed into the living space m Adequate incoming air must therefore always be ensured m An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only whenever the partial v
6. acuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means 4x cM 2x m m This appliance is installed on the wall Follow the enclosed installation instructions for additional special accessories e g for circulating air mode m Ihe surfaces of the appliance are sensitive Avoid damaging them during installation In any case consult your responsible chimney sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the recirculation mode IN Risk of fire from flying sparks Do not install appliance above a solid fuel heater e g wood or coal unless a closed non removable cover is available For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers IN Risk of electric shock from damaged connection cable Do not kink or pinch connection cable during installation IN Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance A Risk of injury from a falling appliance All safety s
7. crews and safety caps must be firmly fitted Installation Pipe dimensions Note The device manufacturer does not assume any warranty for complaints attributable to the pipe section m The device achieves its optimum performance by means of a short straight exhaust air pipe and as large a pipe diameter as possible m Asa result of long rough exhaust air pipes many pipe bends or diameters the optimum extraction performance is not achieved and fan noise is increased m The pipes or hoses for laying the exhaust air line must consist of non combustible material Round pipes An inner diameter of 150 mm but at least 120 mm is recommended Flat ducts The inner cross section must correspond to the diameter of the round pipes 150 mm approx 177 cm 120 mm approx 113 cm m Flat ducts should have no sharp deflections m Use sealing strip for deviating pipe diameters Checking the wall m Ihe wall must be level vertical and adequately load bearing m The depth of the boreholes must be the same length as the screws The wall plugs must have a secure grip m The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks m The max weight of the extractor hood is 40 kg Preparing the installation 1 Mark a vertical centre line on the wall from the ceiling to the lower edge of the extractor hood
8. e flue duct into the other Notes m To prevent scratches place paper for protection over the edges of the outer flue duct Slots of the inner flue duct downwards 4 Place flue ducts on the appliance 5 Push inner flue duct upwards and attach to the fixing brackets on the left and right 6 Press flue duct downwards until it engages B 7 Screw flue duct to the sides of the fixing bracket using two screws DHZ5325 DHZ5345 DSZ5200 DSZ5240 Robert Bosch Hausger te GmbH Carl Wery StraBe 34 81739 M nchen Germany www bosch home com UNI 9000548188 900721
9. r slight discolouration may occur This has no effect on the function of the metal mesh grease filters m Do not clean heavily soiled metal mesh grease filters together with utensils m Place the metal mesh grease filters loosely in the dishwasher The metal mesh greases filter must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop m Soak the metal mesh grease filters in a hot soapy solution m Clean the filters with a brush and then rinse them thoroughly m Leave the metal mesh grease filters to drain Replacing bulbs A Risk of burns risk of electric shock from defective bulbs Switch off fuse or pull out mains plug Always replace defective bulbs immediately leave bulbs to cool down first to prevent the remaining bulbs from overloading Important Use only bulb of the same type and same power see bulb holder or rating plate inside the appliance to do this remove metal mesh grease filter Replacing halogen bulbs Note When inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove bulb ring using a suitable tool 2 Pull out bulb and replace with bulb of the same type 3 Insert bulb cover A Insert mains plug or switch on fuse again Replacing filament bulbs 1 Lift bulb cover slightly and push towards the outside of the appliance 2 Unscrew bulb and repl
10. rasive sponges scouring agents cleaning agents containing sand soda acid chlorine or any other aggressive substances are not suitable m Clean the stainless steel surfaces in the direction of the ground surface only Do not use stainless steel cleaner or wet cloths for the controls With edge extraction 1 Pull metal mesh grease filter downwards In doing so place other hand under the metal mesh grease filter 2 Take metal mesh grease filter out of the holder Notes m Grease can accumulate in the bottom of the metal mesh grease filter Do not hold metal mesh grease filter at an angle otherwise grease will drip out Installing metal mesh grease filter 1 Insert metal mesh grease filter In doing so place other hand under the metal mesh grease filter 2 Fold up metal mesh grease filter and lock Cleaning metal mesh grease filters The inserted metal mesh grease filters absorb the grease particles from the kitchen fumes Clean the metal mesh grease filters under normal use 1 to 2 hours daily approx every three months Notes m Do not use any aggressive acidic or alkaline cleaning agents m When cleaning the metal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth m The metal mesh grease filters can be cleaned in the dishwasher or by hand In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwashe
11. rly clean the metal mesh grease filter from overheated fats and oils Heat fats and oils under constant supervision only Never extinguish fire with water always use a fire blanket lid or plate Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Risk of injury due to LED lights of risk group 1 Do not look directly into the switched on LED lights for longer than 100 seconds Cleaning and care Risk of burns risk of electric shock from appliance Always leave appliance to cool down before cleaning or servicing Switch off fuse or pull out mains plug Caution m Risk of damage due to ingress of humidity into the electronic circuitry Never clean operator controls with a wet cloth m Surface damage due to incorrect cleaning Clean stainless steel surfaces in the grind direction only Do not use any Stainless steel cleaners for operator controls m Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Maintenance and repair Risk of fire risk of injury from improper repairs Switch off fuse or pull out mains plug Repairs may be performed by a qualified technician electrician only Risk of injury from defective or damaged appliance Switch off fuse or pull out mains plug and call customer service Risk of fire risk of injury from damaged connection cable
12. rom appliance Always leave appliance to cool down before cleaning or servicing Switch off fuse or pull out mains plug Removing metal mesh grease filter 1 Open lock and fold down the metal mesh grease filter In doing so place other hand under the metal mesh grease filter 2 Take metal mesh grease filter out of the holder Cleaning and care A Risk of burns risk of electric shock from appliance Always leave appliance to cool down before cleaning or servicing Switch off fuse or pull out mains plug Caution m Risk of damage due to ingress of humidity into the electronic circuitry Never clean operator controls with a wet cloth m Surface damage due to incorrect cleaning Clean stainless steel surfaces in the grind direction only Do not use any stainless steel cleaners for operator controls m Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Cleaning appliance surface Suitable cleaning agents and care products for your appliance can be purchased via the Hotline or from the Online Shop see front of the instructions for use Note The appliance surface and controls are scratch sensitive Observe the warranty regulations in the enclosed service booklet and the following cleaning instructions m Clean the surfaces with a soft damp cloth washing up liquid or a mild window cleaner Soften dried dirt with a damp cloth Do not scratch m Dry cloths ab
13. s Control panel variant 3 Intensive setting Light On Off Fan settings m f the exhaust air is conveyed through the outer wall a telescopic wall box should be used Circulating air mode The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen Note To bind odours in circulating air mode you must install an activated carbon filter The different options of operating the appliance in circulating air mode can be found in the brochure or ask your dealer The required accessories are available from specialist outlets from customer service or from the Online Shop The accessory numbers can be found at the end of the instructions for use Switching on fan variant 1 Press On Off button Increase fan setting by pressing button or reduce it by pressing button Intensive setting You can use the Intensive setting for particularly strong odour and fume generation Keep pressing button until F h is indicated on the display Run time is limited Then the appliance sets automatically a lower fan setting You can always switch back manually Switching on fan variants 2 and 3 Increase or reduce the fan settings by pressing buttons 1 2 and 3 Intensive setting variant 3 Press button f Light The light can be switched on and off independently of the fan Installing and removing filter A Risk of burns risk of electric shock f
14. s WEEE waste electrical and electronic equipment The guideline determines the framework for the return and recycling of used appliances as applicable E Nr FD The numbers can be found on the rating plate inside the appliance to do this remove the metal mesh grease filter Enter the numbers in the above box so that you can easily find them when required Installation Mortal danger risk of intoxication Due to combustion gases sucked back in Never operate the appliance in the exhaust air mode at the same time as a room air dependent heat producing appliance unless an adequate supply of fresh air is ensured Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air is extracted from the kitchen and neighbouring rooms a partial vacuum is produced if not enough fresh air is supplied Toxic gases from the chimney or the extraction shaft are sucked backed into the living space m Adequate incoming air must therefore always be ensured m An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is in
15. sequent use or for the next owner This appliance is designed to be used in the home only The manufacturer is not liable for damage which is caused by improper use or incorrect operation Danger of suffocation from packaging material Never allow children to play with packaging material After unpacking the appliance check it for visible damage Do not connect the appliance if it has been damaged in transit These instructions apply to several appliance models It is possible that individual features are described which do not apply to your appliance Adults and children must never use the appliance unsupervised if they are not physically or mentally capable of doing so or if they lack the knowledge and experience to operate the appliance correctly and safely Never allow children to play with the appliance Please contact our customer service regarding any queries or faults see list of customer service centres When calling please quote the following numbers INSTALLATION INSTRUCTIONS 22 222 2022 2200200000 00n0nnn0n0n0 7 Installation instructions uu u 2200220n u00nn0nnnunn nun ann 7 RUE NOIES css i a 7 MStar 8 FINS SOS einher 8 Checking the Wil ae 8 Preparing the Il Adlon 8 NS Ta Al ee een 8 Attaching TW NS ee 10 Environmental protection K This appliance is labelled in accordance with the European Directive 2002 96 EU concerning used electrical and electronic appliance
16. stalled does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible chimney sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood iS operated exclusively in the recirculation mode Risk of fire from flying sparks Do not Install appliance above a solid fuel heater e g wood or coal unless a closed non removable cover is available Caution Risk of damage from heat accumulation due to too narrow gap between appliance and high sided unit or wall Only one side of the appliance may be installed directly next to a high sided unit or a wall Distance between the appliance and wall or high sided unit must be at least 50 mm The specified safety distances must be observed Also observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas Suppliers Risk of electric shock from damaged connec
17. tion cable Do not kink or pinch connection cable during installation Risk of fire risk of injury from damaged connection cable A damaged connection cable must be replaced by a qualified technician electrician Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Risk of injury from a falling appliance All safety screws and safety caps must be firmly fitted Using the appliance Risk of burns from hot appliance when used with cooking appliances Keep children away and ensure appliance is used properly Risk of injury risk of damage from objects falling on the appliance Never place objects on the appliance Risk of fire risk of burns if gas hotplates not covered with cooking utensils Always use gas hotplates with appropriate cooking utensils Regulate flame to ensure that it does not lick over the cooking utensil Risk of burns risk of damage if several gas hotplates are operated simultaneously Never operate two gas hotplates simultaneously on the highest flame for longer than 15 minutes The housing will become very hot due to the intense heat Note One large burner of more than 5 kW Wok Is equivalent to the power of two gas burners Risk of fire m from grease deposits in the metal mesh grease filter Never work under the appliance with a naked flame e g flambeing Always operate appliance with metal mesh grease filter Regula

Download Pdf Manuals

image

Related Search

Related Contents

HR7775, HR7774  ダウンロード  Samsung 21,5" SyncMaster LD220HD LS22FMDGF/XE Bruksanvisning    HOJA DE DATOS DE SEGURIDAD  Setup & User Guide  gml 24 v gml 24 v  A - N° 82 / 31 décembre 1990  

Copyright © All rights reserved.
Failed to retrieve file