Home
Draper Ultimate Access/Series V
Contents
1. Copyright 2011 Draper Inc Form UltimateAccess220V_Inst 1 R Printed in U S A Case dimensions on page 4 US Patent Nos 5 341 241 6 137 629 6 421 175 6 532 109 6 816 308 7 559 707 must be free of mastic or paint build up and trapdoor and access panel must be unobstructed by ceiling tiles If case is painted on location removal of roller fabric assembly is recommended prior to painting If not removed slots on bottom of case should be shielded to protect viewing surface from paint splatters or overspray Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully Electrical Connections Screen operates on 220 V AC 50 Hz current Junction box is located just above the bottom access panel at left end of screen Open the access panel trap door for access to the junction box cover See bottom access panel trap door opening and closing instructions below Remove two 2 hex head screws that secure the cover to the junction box to expose the brown black and blue pigtail leads and the green ground wire per wiring diagram on page 4 If optional low voltage control or video interface control is specified and factory installed please refer to wiring diagram on page 4 Screen is shipped with internal wiring complete and control switch es fully boxed Wire to connect screen to switch es and switch es to power supply should be furnished by installer Connect
2. Operation When screen is first operated be cautious Cycle unit down and up several times to confirm satisfactory operation 220V SINGLE STATION CONTROL 3 position UP OFF DOWN switch permits operation to be stopped at any point Factory adjusted limit switch es automatically stop screen when fully down or fully up 220V MULTIPLE STATION CONTROL Not CE approved Switches are similar in appearance to 220V Single Station Control Screen stops when switch is released and may be restarted in either direction Factory adjust ed limit switches stop screen automatically when fully up or fully down 24V MULTIPLE STATION CONTROL Three button UP STOP DOWN switches stop at any point desired operate in any sequence Factory adjusted limit switches automatically stop screen when fully up or down 220V amp 12V VIDEO INTERFACE CONTROL Not CE Approved Allows screen to be controlled by a trigger signal when signal comes on screen descends automatically Two versions Model VIC220 integrates screen op eration with a DRAPER video projector lift or a video projector or tuner with a 220V switched outlet Model VIC12 interfaces with 12V switched outlet Both available with override switch VIC OS permitting independent operation VIC OS not available with factory installed VIC220 amp VIC12 KEY OPERATED SWITCHING Two kinds of key operated switches are optionally available with this unit The key operated power supply switch controls power to
3. Screen Wiring Wnite or Blue Common to screen amp 110 220V AC Neutral White Blue Common l F Red to screen directional roo Red 110 Black 220 Up Brown to screen directional 4 4 Black 110 Brown 220 Down Yellow to 110 220V AC Hot i need w 3 Green Yellow RBlack to 110 220V AC Hot aie A Motor Ground Green Yellow Ground Iolar wee fi fai Soe eee Dashed wiring by electrician eee rer ae re Low voltage wiring by others Oho wens E To Eye Port for IR Eye RF Receiver or LED l BoP l 110 220V Wall Switch For more than one of p o Line these a splitter is required ees 3 Button Wall Switch ean okey f DOWN gt Black ee eee Snitch t furnished UP Red 5 Control Aux Port for connecting additional LVC III Switches n modules up to six total can be linked 24v DC connect from Aux to Eye Internal Screen Wiring White or Blue Common White Blue Common Red to Screen directional 7 Red 110 Black 220 Up Black to Screen directional Black 110 Brown 220 Down ProgramLED Brown Hot to AC eat Green 110V H Green Yellow Ground tot ju gt Green Yellow 220V 1 ni S Motor Ground Ser euery Low Voltage Wiring by others _ F Fuse Lo TERES AC Wiring by clectticran rt 1 i RS232 Data FROM Control System tat RS232 Data TO Control System Ke Signal Ground amp Manual Switch Common mot Manual Swit
4. screen and switches When it is off the switches will not operate screen Key may be removed from the switch in either on or off position A three position key switch permits screen to be operated directly by key In this case the screen s operator must always have a key RS232 Ethernet Serial communication and network communication optionally available with wall switches RF or IR remote Adjustments Please Note Screen limits are factory set for optimum performance of the screen Any adjustment of these limits could void the war ranty Please check with Draper prior to resetting screen limits A CAUTION Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down A CAUTION Be sure all switches are in off position before adjust ing limit switches Fabric unrolling from back Fabric unrolling from front of roller of roller Left hand motor Left hand motor White Socket Down White Socket Up Yellow Socket Up Audience Yellow Socket Down Audience side side ADJUSTING WHITE SOCKET White socket is located on motor end of screen roller and is accessible to a small flat screwdriver or a 4 mm s2 hex key Turning socket counterclockwise will allow the roller to run farther up or down as appropriate Turning it clockwise will shorten operation causing screen to stop sooner One full
5. Installation Operating Instructions 220V Ultimate Access Electric Projection Screen by Draper These Installation Operating Instructions are available in the official language of the country where you purchase the product Please contact your distributor to request a copy Vous pourriez demander les instructions d installation et d op ration traduises dans la langue officielle du pays ou vous achetez le produit Veuillez demander a votre distributeur Die Gebrauchsanweisung f r Installation und Konstruktion sind in der offiziellen Sprache des Landes indem Sie das Produkt gekauft haben vorhanden Fragen Sie die jeweilige Verkaufs Abteilung A Caution Read instructions through completely before proceeding Follow instructions carefully Installation contrary to instructions invalidates warranty Entire bottom of screen case should be unobstructed to permit access to bottom panel for electrical connections or servicing Screen should be installed level using a carpenter s level Nothing should be fastened to screen dowel or viewing surface Operating switch es and mounting brackets are packed separately in screen carton Do not discard with packing material Screen operates on 220 V AC 50 Hz current NOTE Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment e00 Hanging Screen When locating viewing surface and checking clearance for screen s operat
6. ch Down fi Manual Switch Up a A 471 Location of key i ted on off MC1 Eye Port for IR Eye For RF Receiver or LED 1 Operated on a Wall Switch a Splitter and a Power Supply Loa switch if furnished is required Plug RF Receiver or LED Wall a Switch and Power Supply into splitter then 1 run cable from Splitter to MC1 Eye Port To AC Line See separate Serial Communication RS232 Instruction sheet for enabling RS232 with the MC1 www draperinc com DRAPER 765 987 7999
7. ded 254 25 mm Mee tammy NIIR Aos mee A Series E Series V Ceiling tile Viewing Surface Viewing Surface 21 8 by others n A Series E Series V L 208mm Varies Alternative mounting configuration www draperinc com DRAPER 765 987 7999 220V Ultimate Access by Draper Wiring Diagrams Please Note Do not wire motors in parallel Page 4 of 4 Single Station Control Junction box at Multiple Station Control Junction box at CE Approved left end of screen Not CE Approved eft end of screen as W at Internal Screen Wiring Internal Screen Wiring panenn ie Blue 220v Common r j Blue 220v Common 0 Brown 220v Down Brown 220v Down it Gh _ _ _ Black 220v Up 1 1 Black 220v Up aa ri raza e 3 Green Yellow Motor Ground h f 3 Green Yellow Motor Ground lot l UR j lod Por rol A Eob i 14 i Cap off with wire o ivi nut amp tape Doi 14 L E p ii l i n Ses L Soe Coirea ee iy Control switch _L l T 5 l Dashed wiri a 1 ashed wiring 3x i by installer ea l 220v i gt Hi 50 Hz 5 5 Dashed wiring a gt OL 2 by installer zZ 220v 50 Hz Low Voltage amp Wireless Control Internal
8. enter of screen case to allow the trap door assembly to be pivoted to its closed po sition Make sure that the spring latch levers engage fully with case endcaps and center of case where appropriate Caution Beware of pinch points along closure If you encounter any difficulties installing or servicing your Ultimate Access screen call your dealer or Draper Inc in Spiceland Indiana 765 987 7999 or fax 765 987 1689 220V Ultimate Access by Draper Motorized Roller Fabric Installation The bottom access panel trap door assembly must be opened and placed in fully opened position first The motor end mounting bracket has a metal bracket with snap ring for ac cepting motor head Back out the four set screws in bracket until they are flush with top side of bracket To engage the motor end bracket flange above the two channels in the top of the screen housing rotate the bracket approximately 45 counterclockwise to allow the top surface of the motor bracket to rest flat against the top inside of the hous ing Rotating the bracket clockwise until it is engaged with the channels slide it along the length of the housing against the electrical junction box Engage the idler end bracket rectangular mounting pad in the same manner as the motor end bracket and slide it toward the opposite end of the screen housing Do not tighten the set screws on the brackets until the roller fabric assembly is installed and cent
9. ered in the case Locate the black washer and retaining clip Note This will require two people to perform safely Raise the roller fabric assembly up into the screen housing and engage the head of the motor completely into the motor mounting bracket making sure the snap ring engages with the motor and that the limit switch adjusting knobs are visible from the bottom of the screen housing While supporting the idler end of the roller slide the idler end mounting bracket toward Retaining the roller Insert the roller pin into the nylon clip bushing on the idler end mounting bracket Motor roller Washer The roller idler pin needs to go through assembly the idler bracket far enough to allow the washer and retaining clip to be reinstalled on the pin Idler end roller mounting bracket Failure to replace the washer and retaining clip as shown could result in the sepa ration of the roller from the brackets The roller fabric assembly and roller brackets may need to be slid left or right in mounting channel of case to center fabric within screen case Securely tighten the set screws on the roller mounting brackets Connect the electrical plug from the motor to the mating socket on the junction box Close the bottom access panel trap door as previously described Motorized Roller Fabric Removal Reverse the instructions above under Motorized Roller Fabric Installation for removal of the unit Page 2 of 4
10. ion remember surface is centered in the length of the case Screen is normally recessed above ceiling and may be installed in a variety of ways See typical installations detailed on page 3 Regardless of mounting method used the following points apply Mounting brackets are packed separately in carton Engage each bracket with top of housing as shown below and tighten set screws A bracket should be within 46 cm from each end of screen case Brackets can be removed and case mounted with lag screws through top of case holes drilled on site Screen should be positively and securely supported so that vibration or even abusive pulling on viewing surface will not weaken installation Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen Entire bottom of case must be readily accessible after installation is complete The bottom access panel trap door and lower edge of the case are joined with continuous hinge joints and must operate freely Front and back of case must be straight not forced to warp or bow Hinge joints Remove shipping brackets before operating screen Slots along top of case permit brackets to be set at an angle Typical Installation Shipping Bracket Alternate Installation additional ets required but not in cluded Tigh 411 S Pearl St Spiceland IN 47385 USA I 1 765 987 799 www draperinc com I fax 1 765 987 1689
11. ions should be made in accordance with attached wiring diagram and wiring should comply with national and local electrical codes All operating switches should be off before power is connected Bottom Access Panel Trap Door Opening amp Closing After screen case has been mounted remove the dowel shipping brackets from dowel if provided A spring latch at each end of the trap door holds this assembly closed In some screens there will also be a spring latch near the center of the case To gain access to inside of screen case disen gage spring latch at each end of the case and near the center of the case if applicable by sliding the latch lever towards the center of screen case then pull down slightly on the trap door assembly The latch levers are somewhat concealed from view Locate these with the trap door open by feeling for the vertical latch lever above the door about 8 cm from case endcaps and near the center of the case The assembly will swing down opening about 135 Pivot the prop arms at each end of the trap door assembly towards the ends of screen case Prop arms engage with a hole in each endcap to hold the trap door assembly fully open To close the trap door assembly disengage prop arms from endcaps and pivot these over the access panel Swing the trap door assembly upward stopping just before the latch levers hit the bottom flanges of the endcaps and center of case where appropriate Pull levers of latches towards c
12. revolution of the socket will alter the stopping position of the viewing surface by approximately 32 mm ADJUSTING YELLOW SOCKET Yellow socket is located on the motor end of screen roller and is accessible to a small flat screwdriver or a 4 mm s2 hex key Turning the socket counterclockwise will allow the roller to run farther up or down as appropriate Turning it clockwise will cause the roller to stop sooner One full revolution of the socket will alter the stopping position of the viewing surface by approximately 32 mm AT NO TIME SHOULD VIEWING SURFACE BE UNROLLED ENOUGH TO EXPOSE ANY PART OF SCREEN ROLLER www draperinc com RARER 765 987 7999 220V Ultimate Access by Draper Page 3 of 4 Tab Tension Adjustment Procedure for Ultimate Access Series V Determine which side requires adjustment Secure dowel with one hand Z Caution Do not touch or bend surface Using Philips head screwdriver depress spring loaded adjustment screw see drawing and slowly turn clockwise to tighten tension or counterclockwise to loosen tension The screw adjusts in 14 turn Dowel a Tensioning Cable increments Adjust only one increment 14 turn If problem is not corrected leave screen in position for 24 hours to allow surface material to stretch into position If problem still is not corrected repeat steps 2 and 3 Adjustment Screw ke Case Dimensions Mounting brackets slide left and right as nee