1. A Always comply with the currently valid regulations and installation instructions sup plied by the gas appliance manufacturer A Only one side of the extractor hood may be installed next to a high sided unit or high wall Gap at least 50 mm A Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood 650 mm Prior to installation Exhaust air mode a a The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located Exhaust air may be discharged in accordance with official and statutory regulations only e g national building regulations Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use When the extractor hood is operated in exhaust air mode simultaneously with a different burner which also makes use of the same chimney such as gas oil or coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Saf
2. cloth only Painted aluminium and plastic surfaces QO Do not use scouring agents or abrasive sponges Q Do not use dry cloths QO Do not use corrosive acidic or alkaline cleaning agents U Note Do not use alcohol spirit on plastic parts otherwise the surface may become matt in appearance Caution Ensure that the kitchen is ade quately ventilated Avoid naked flames Changing the bulbs Candle bulbs 1 Switch off the extractor hood and isolate by pulling out the mains plug or swit ching off the disconnector on the instal lation side 2 Remove the filter frame U See grease filter 3 Replace the bulb standard filament bulbs max 40 watt E 14 bulb holder 4 Attach the filter frame Q See grease filter Cleaning and care Halogen bulbs 1 Switch off the extractor hood and isolate by pulling out the mains plug or swit ching off the disconnector on the instal lation side A When switched on the halogen bulbs become very hot Even for some time after the bulbs have been switched off there is still a risk of burns Remove the bulb ring with a screwdriver or similar tool Replace the halogen light bulb conventional halogen bulb 12 Volt max 20 Watt G4 cap Caution Refer to for plug in lampholder Take hold of the bulb with a clean cloth 4 Re insert the bulb ring 5 Plug the appliance into the mains or switch it on at the fuse box Note If the light do
3. been removed it must be re installed 6 Re insert the two filter cartridges Removing the activated carbon filter Q The activated carbon filter is removed in reverse sequence Changing the activated carbon filter If used normally 1 to 2 hours daily the activated carbon filter should be changed approx once a year Activated carbon filters can be purchased from SPECIALIST OUTLETS see optional accessories on the last page Use original filters only This will ensure optimum performance Disposing of the old activated carbon filter Activated carbon filters do not contain any pollutants They can be disposed of e g as residual waste Cleaning and care Switch off the extractor hood and isola te by pulling out the mains plug or swit ching off the disconnector on the instal lation side QO At the same time as you renew the grease filter see Filters and maintenance clean off any grease from all accessible parts of the housing This significantly reduces the fire hazard and ensures that the extractor hood performs as effectively as possible Q Clean the extractor hood with a hot detergent solution or a mild window cleaning agent If the hood is extremely dirty older stains use a liquid window cleaner QO Do not scratch off dried on dirt but wipe off with a damp cloth QO Do not use scouring agents Warning Clean the control buttons with a mild detergent solution and a soft damp
4. SIEMENS Operating and installation instructions LB 23 LB 54 LB 75 Operation Instructions Operating modes Exhaust air mode QO The extractor hood fan extracts the kit chen vapours and conveys them through the grease filter into the atmos phere Q The grease filter absorbs the solid particles in the kitchen vapours QO The kitchen is kept almost free of grease and odours Circulating air mode Q An activated carbon filter must be fitted for this operating mode see Filters and maintenance Activated carbon filters can be purchased from specialist outlets see Optional accessories on the last page U The ventilator fan draws the vapours produced during cooking into the extractor hood where they pass through the grease filter and the activa ted carbon filter before the clean air is discharged back into the kitchen U The grease filter absorbs the grease contained in the vapours produced during cooking U The activated carbon filter absorbs any odorous substances When the extractor hood is operated in exhaust air mode simultaneously with a different burner which also makes use of the same chimney such as gas oil or coal fired heaters continuous flow heaters hot water boi lers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that t
5. ance if damaged A The appliance may be connected to the mains by a qualified technician only A The appliance is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance Ai the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his custo mer service or a similarly qualified person in order to prevent serious injury to the user A Dispose of packaging materials properly see Installation instructions A This extractor hood is designed for domestic use only A Light bulos must always be fitted when the extractor hood is in use A Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading A Never operate the extractor hood without a grease filter A Overheated fat or oil can easily catch fire If you are cooking with fat or oil e g chips etc never leave the cooker unattended A Do not flamb food directly under the extractor hood Risk of grease filter catching fire due to flames QO Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance QO Please retain the operating and installation instructions for a subsequent owner A The hotplates must always be covered
6. ap Q Insert the two lugs on the one way flap into the holes on the air pipe connector or air outlet and lock into position A Before installing the one way flap ensu re that the lettering or stamp is on the out side 11 Prior to installation Optimum performance of the extractor hood Q Short smooth extraction pipe As few pipe bends as possible Q Largest possible pipe diameter prefera bly 150 mm and large pipe bends Round pipes We recommend for single motor model inner diameter of at least 120 mm for double motor model inner diameter of at least 150 mm Flat ducts must have an inner cross section equivalent to round pipes which have an inner diameter of 120 150 mm 120mm approx 113 cm 150 mm approx 177 cm Q If pipe diameters differ use sealing strip QO Ensure an adequate air supply for exhaust air mode Pipe connection Extractor hoods with 120 mm air outlet 100 mm extraction pipe Q Insert the reducing connector see optio nal accessories on the last page into the air pipe connector and then attach the exhaust air pipe 120 mm extraction pipe Q Attach the exhaust air pipe directly to the air pipe connector 12 Extractor hoods with 150 mm air outlet 150 mm extraction pipe Q Screw the reducing connector see optional accessories on the last page onto the air outlet Q Attach the extraction pipe to the redu cing connector 150
7. ardous situation Improper repairs may put the user at considerable risk Length of connection cable 1 20 m Electrical specifications The electrical specifications can be found on the rating plate inside the appliance when the filter frame has been removed A Do not place hand in the air outlet This appliance complies with the EC radio interference suppression regulations Installation The extractor hood is particularly suitable for installation in a flue or chimney To ensure optimum extraction perfor mance especially important for kitchen island solu tions Q Install the extractor hood as high as possible within the structure Q The structure must cover the entire cooking area The following cutouts must be made for the installation depending on the model Extractor hood with rocker switch 53 cm wide 1 motor a PIB 248 120 2100 13 Installation Extractor hood with slide control 53 cm wide 1 and 2 motor m b we 88 un Na S S ee i 150 2120 N eg 14 Extractor hood with slide control 73 cm wide 1 and 2 moto
8. e operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if the combustion air can be replenished by being able to flow through non closeable openings such as in doors windows wall ventilation boxes or by alternative technical measures such as reci procally shutting the other device off etc Pa a T If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and ovens All legal requirements concerning the discharge of exhaust air must be observed Unrestricted operation is possible if the extractor hood is used in recirculating mode with activated carbon filter The extractor hood should be fitted with a one way flap for exhaust air mode if there is not already one installed in the exhaust air pipe or wall box If a one way flap is not enclosed with the appliance purchase one from a specialist outlet see optional acces sories on the last page Attaching the one way fl
9. es not function check that the bulbs have been inserted correctly Installation Instructions Important information A Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance render it unusable UN You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal UN The extractor hood can be used in exhaust air or circulating air mode UN Aways mount the extractor hood over the centre of the hob A Minimum distance between electric hob and bottom edge of extractor hood 650 mm A the extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are observed UN The smaller the gap between the extractor hood and hotplates the greater the likelihood that droplets will form on the underside of the extractor hood 10 Additional information concerning gas cookers UN when installing gas hotplates comply with the relevant national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI
10. he underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and ovens Unrestricted operation is possible if the extractor hood is used in recirculating mode with activated carbon filter A If no activated carbon filter is installed it is not possible to bind the odorous substances in the cooking vapours Before using the first time Important notes Q The Instructions for Use apply to several versions of this appliance Accordingly you may find descriptions of individual features that do not apply to your specific appliance QO This extractor hood complies with all relevant safety regulations Repairs should be carried out by qualified technicians only Improper repairs may put the user at considerable risk A Do not use the appli
11. he vapour extractor tray has been pushed back into the hood Filters and maintenance Various types of grease filter can be used to absorb the grease contained in the vapours produced during cooking Fleece grease filter The filter mat is made from material that is itself virtually non inflammable Caution AS it becomes more and more saturated with grease however the filter becomes increasingly inflammable The efficiency of the extractor hood can also be adversely affected Important Renewing the fleece filter at appropriate intervals prevents the possibility of it catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place Renewing the fleece filter Q Under normal operating conditions 1 to 2 hours per day the fleece filter will require replacing after 8 to 10 weeks Printed fleece filters must be renewed no later than when the colou red printing has started to fade U Use only original replacement filters In so doing you will ensure that safety regulations are upheld and the extractor hood performs as effectively as possi ble Disposing of the old fleece grease filter Fleece grease filters do not contain any pollutants They can be composted and disposed of as biodegradable waste Filters and maintenance Metal grease filter The filter mat is made of non combustible metal Caution As it becomes more and more saturated with grease the fi
12. lter also becomes increasingly inflammable The efficiency of the extractor hood can also be adversely affected Important Clean the metal grease filter at regular intervals Cleaning the metal filter Under normal operating conditions 1 to 2 hours per day the metal grease filter will require cleaning after 8 to 10 weeks Q The filter can be cleaned in a dishwasher This can however cause slight discoloration Important Metal filters that are heavily saturated with grease should not be cleaned at the same time as any crockery etc U If the filter mat is going to be cleaned by hand soak it first of all in a hot deter gent solution for several hours Clean the filter with a brush rinse it off thoroughly and allow it to drip dry U Use only original replacement filters In so doing you will be ensuring that the extractor hood performs as effectively as possible Removing and installing the grease filter Extractor hoods with a filter mat 1 Rotate the handles on the left and right of the filter grille OOOO i ere 4 OOO Ss ae Z CG JO y a 2 Press the retaining spring and remove the filter frame 3 Remove the wire grille and replace the filter mat 4 Install the filter frame in reverse sequence A Re attach the retaining spring UN The left and right sides of the filter frame must lock into position Activated carbon filter Filters and maintenance Remo
13. mm extraction pipe Q Attach the exhaust air pipe directly to the air outlet Afa one way flap has been fitted con duct a performance test Extractor hoods with rectangular air outlet T Q Screw the enclosed T air pipe connector over the air outlet MM Recirculated air mode Par Q The air cleaned by an additional activa ted carbon filter is conveyed back into the room Q In recirculated air mode the exhaust ope ning must be protected by a grille see optional accessories on the last page in order to prevent a mechanical or electri cal hazard Electrical connection The extractor hood must be connected to a correctly installed earthed socket only Attach the earthed socket as close to the appliance as possible and in an accessible position If the earthed socket is no longer accessible following installation of the extractor hood a disconnector must be provided on the installation side Dis connectors are switches with a contact opening of more than 3 mm and all pole disconnection LS switches and contactors are regarded as disconnectors The appliance must be isolated before repairs are carried out Repairs may be carried out by authorised technicians only A If the connection cable of this appliance is damaged it must be replaced by the manufacturer his customer service or a similarly qualified person in order to prevent a haz
14. r 696 gt m oa E Installation 1 Remove the filter grille see operating instructions 2 Connect the power 3 Press the extractor hood up into the installation opening until the installation aid locks into position at the front and rear 4 Screw in the extractor hood 5 Insert and secure the filter grille see operating instructions Weight in kg A Exhaust Recircu Model Width ato a 1 motor Slide contr 11 6 2 motor Slide control 53cm 8 3 9 5 si Dio 2 1 Slide control 73 cm 8 7 9 9 Design changes with respect to technical development shall remain withheld Removal 1 Loosen the screws 2 Hold the underside of the extractor hood Hold the underside of the extrac tor hood Installation spring 3 Lower the extractor hood and remove 15 LZ 23000 LZ 72040 LZ 73040 LZ 73050 461423 481051 095660 9000 018538 Siemens Elektrogerate GmbH Printed in Germany 0904 Hi
15. ving and installing the activa ted carbon filter Extractor hoods with two filter cartridges Warning The halogen bulbs must be swit ched off and cool Extractor hoods with a filter mat 1 Remove the filter see grease filter Q The wire grille is no longer required when an activated carbon filter is installed in the direction of the arrow and fold down the grease filter slightly Detach the grease filter by pulling it towards 1 Depress the detent on the grease filters yourself 2 Place the activated carbon filter on the filter mat and clamp it in 2 Clean the grease filters 3 Re i insert the clean grease filters Install the filter frame USee grease filter 3 Activated carbon filter Extractor hoods with two filter cartridges 1 Remove the filter cartridge Q See grease filter 2 Insert the screw through the wing nut and the sleeve and screw in the middle screw in the false bottom required only during the initial installation Screw sleeve and wing nut are enclosed with the activated carbon filter 3 Using a screwdriver press in the two lugs on the false bottom If a spacer rail has been installed it must be removed 4 Tape over the activated carbon filter with the enclosed sealing strip 5 Insert the activated carbon filter at the rear fold up and lock in the middle with the wing nut If the spacer rail has
16. with a utensil A Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Installation instructions Gas hobs Gas cookers A Do not use all the gas hotplates simultaneously for a prolonged period max 15 minutes at maximum thermal load otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood If the extractor hood is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously If you encounter a problem If you have any questions or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following E Nr FD Enter the relevant numbers into the box above The E Nr product no and FD production date are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached How to operate the extractor hood AN The most effective method of remo ving vapours produced during cooking is to Q Switch the ventilator ON as soon as you begin cooking Q Switch the ventilator OFF a few minutes after you have finished cooking Operating controls on different models Light Intensive setting Fan settings JET Light Intensive setting SG Fan settings Note The light can be switched on at any time including when t
Download Pdf Manuals
Related Search
Related Contents
bdiNDI_UserManual_CPU32_32+ エアコンのお手入れ方法 St. Lawrence Martyr School Fun Run Website User Manual USER MANUAL - Bandshed.net PDF Manual de instrucciones DS-W 10.5 (ES), 316.5 kB Todos os avisos de segurança fornecem detalhes específicos do Danses de toutes les Bretagnes インターネット接続・メール設定 A Saint-Denis, les fenêtres dans tous leurs éclats М8247/07186 Copyright © All rights reserved.