Home
Longshine LCS-C844 network media converter
Contents
1. 30 SNMP Configuration 31 System Restart 33 Command Line Interface 35 Command Definitions 35 Web Browser 37 Appendix A ceres 46 Serial IP 46 1 Introduction About This Guide Welcome Thank you for selecting the RS 232 422 485 to 10 100Base TX Device Server This unit is designed to provide a RS 232 422 485 connection over twisted pair cable where the connected devices have RS 232 422 485 interfaces Enabling serial devices such as CNCs and PLCs to instantly connect to an existing Ethernet Fast Ethernet network the Serial to Ethernet Device Server represents a robust solution for devices controllers for MIS personnel Purpose This guide discusses how to install and configure your RS 232 422 485 to 10 100Base TX Device Server Terms Usage In this guide the term Device Server first letter upper case refers to your RS 232 422 485 to 10 100Base TX Device Server and device server first letter lower case refers to other device servers Features e Complies with EIA TIA and IEEE standards e Supports 4 wires full duplex asynchronous serial data transmission RS 422 485 e Supports 2 wires hal
2. 2 Internet System Details This category has two options of System Info and Master Info a System information is as shown above will show IP Address Subnet Mask and Gateway 38 settings After editing the setting press Apply to implement the settings b Master Info will show the hardware and firmware version Master Information Hardware Version 6700 00633 0100 Firmware Version 1 00 02 built at Jan 9 2006 11 17 12 Configuration User can monitor the serial port status and configure TCP port number from this menu a Serial Port Config window will show you the serial port configuration and allow to assign the TCP port number to operate via Serial IP Redirector software RS232 422 485 Transfer Configuration Server Client Mode Configuration Server Client Type SERVER TCP Port Number 1234 value 1024 65535 Packet mode of serial input Disable Packet mode inter packet timeout 20 ms value 10 5000 Serial Port Configuration Operation Mode X Baud Rate 38400 Parity None Word Length 8 Stop Bits Bal Flow Control NONE Reset Apply 39 In case you are using serial device with 2 wire RS 485 application or Modbus protocol do not forget to Enable Packet mode of serial input Also put appropriate inter packet timeout value to allow the smooth data communication b Serial Connect Status will show the serial port connection to the serial devi
3. Comnand List Help commands backup configuration file Logout Help comnands logout Logout lIping Ping a specified host with IP address eset Reset system or reset factory default setting Set commands Show commands pgrade Upgrade run time firmware or configuration file 11 gt Command List Command Definitions backup Use this command to save configuration settings to file exit Type exit or logout and press ENTER to quit the program help To access help commands list logout To logout from the device server 35 ping reset show set NOTE Type ping followed by a space and then the IP address of the device to send a test signal If a response is received then the device is connected To view a full list of ping options type ping and press ENTER Type reset config and press ENTER to load factory default settings or type reset system and press ENTER to restart the system Type show to display variety of device server settings To configure the management settings type the commands below followed by the ENTER key Separate each port of the command line with a space set admin follow the prompts to change user name and password set the command is for factory setting use set ethO ip new address network mask new network mask gateway new gateway Use this command to set new Ethernet set
4. lt Enter gt to change the value Once change the value select lt SAVE gt to apply the changes System Information Description Serial IP Device Server Model Name RS 232 422 485 To ETH Device Server Company Name Board 6700 00633 0108 MAC 1 Address 1 88 88 84 91 88 01 DHCP Client Disabled IP Address Fai 92 168 6 200 Subnet Mask 255 255 8 8 Gateway 192 168 8 1 lt SAUE gt lt Tab gt to move lt Enter gt to select After entering the new IP address The system will confirm whether the operation is successful NOTE Copy the new address down on a piece of paper You will need the address when you are going to use Telnet or set up data transfer communication connection Warning IP addresses are unique If an address isn t available please contact the appropriate authorities to apply for one Telnet Access The Device Server is accessible via a Telnet At the command prompt type telnet 192 168 0 254 If connecting with default IP You will be prompted to 21 Enter user name and password as mentioned and shown in the topic Console Port Access Use CLI or Menu driven interface to perform the changes NOTE The only limitation of Telnet Access is that users can not assign new IP address to device server Please use Console Port Access or Web Access to assign new IP address Web Access The Device Server is accessible via a web browser once connected to the network Type the
5. Server cl SeriaVIP Control Panel 4 3 2 Configuration of COM3 Port Number COMS IP Address Conneqtto server 192 168 0 200 Accept Connections Configuration Wizard 1234 User Credentials Use Credentials From COM Port Options DSR Emulation DED Emulation CIS Emulation DIR is modem escape Restore Failed Connections Select Ports Port Monitor Licensing Advanced we About After assigning the IP address and port number press Configuration Wizard button to check if the link is established 47 the following screen press 9 Stat button If the link is function well the following screen will appear Configuration Wizard COM3 t3 IP Address of Server Port Number 192 168 0200 1234 Test for presence of a modem connected to the server Status Connected to Server COM Port Control Support Detected Telnet Protocol Detected Server signature Serial IP Device Server Session Completed Port Option CTS Emulation disabled Security Disabled 9 Start 92 Use Settings ER Cancel If the link has trouble the error message will appear To solve the problem please check the following a Whether IP address and Port numbers are correct 48 b DIP Switch 1 is at OFF position for data trans
6. off Port is operating at full duplex On Green Receiving data packets RS 232 422 485 data ACT Flashing packets being transmitted or received Off No data packets received POST On Green Indicates normal operation Off Device Server is off line 17 5 Configuration There are two separate methods for configuring this Device Server for use In the first section of this chapter the Command line Interface CLI or Menu driven interface via the Console Port to set the device IP and TCP configuration to monitor managed the attached serial device via Serial IP Redirector software The second section will describe CL or Menu driven via Telnet configuration Firstly make the connection below Device RS 232 Cable Server lt gt 3 Female Computer DIP Switch 1 set to ON position Console Port Access The Device Server is accessible via a terminal emulator attached to the RS 232 console port Please follow the step below 1 Attaching the serial cable to COM of computer and serial port of device server 2 Select Hyper Terminal from start menu programs gt Accessories gt communication 18 window will appear assign the connection name Then select the correct available COM port COM1 or COM2 After this enter the port settings as below Bits per seconds 38400 Data bits 8 Parity None Stop bits 1 Flow Control None 3 Once connection is established you will see a log in sc
7. 1 About This Guide 1 2 3 Package Contents 5 2 Hardware 6 Product 6 Product Illustrations cesses 7 Installation noe are 8 LOCATION reote 9 Wall Mount Installation 10 Din Rail Mount Installation 10 Powering On 12 Connecting Copper Cable 13 DB9 Male Connector Pin Assignments 14 Serial Connection 15 Definition of DIP Switches 15 4 LED 17 5 Configuration eere 18 Console Port Access 18 amp 21 Web 5 22 6 Management essen nnne 24 Via Menu Driven Console Port amp Telnet 24 System Information 25 DHCP Configuration Menu 26 RS 232 422 485 Transfer Configuration 26 Monitor 2 004040 20 0 29 TFTP Firmware Upgrade
8. community string If the SNMP Network Management Station only knows the set community string it can read and write to the MIBs However if it only knows the get community string it can only read MIBs The default get and set community strings for the Device Server are public 32 System Restart Menu This menu allows users to restore the factory default setting for the Device Server and or to reset the system manually Selecting this option will lead to another window with the following two options to select System Restart Menu Restore Factory Default Settings System Reset Exit lt Tab gt to move lt Enter gt to select System Restart Menu Restore Factory Default Settings Selecting this option will lead to restore factory default settings to the device server Highlight the field and hit the lt ENTER gt key to execute System Restart The System Restart allows a user to perform a warm restart and validate newly saved configuration to the 33 device server Highlight the System Restart field and hit the lt ENTER gt key to reset the unit Warning After each configuration session be sure to set DIP switch 1 to the OFF position Otherwise the device server will not transmit any data 34 Command Line Interface Once you logged in and select the option of Command Line Interface a window with command prompt will appear Type or help and it will show you the command list
9. must use a power cord set that has been approved for the receptacle type and electrical current in your country Connecting Copper Cable The 10 100BASE TX RJ 45 Ethernet port fully supports auto sensing and auto negotiation 1 Insert one end of Category 5 twisted pair cable into an available RJ 45 port on the Device Server and the other end into the port of the network node 2 Check the corresponding port LED on the Device Server to make sure that the connection is valid Refer to LED chart in next section NOTE The RJ 45 port accepts both straight through and cross over Ethernet cables without the need to re configure the port DB9 Male Connector Pin Assignments 6 1 7 2 9 5 See ee duplex Full Half Direction duplex duplex 1 DCD OUT 2 RX RX DATA B IN 3 TA TX 4 m 5 GND GND GND 6 DSR OUT 7 RTS RX IN 8 CTS TX OUT 9 RI N NOTE Bi directional RS 485 BUS line 14 Serial Connection This Device Server features DIP switches on the rear panel that sets the unit to the correct type of cable configuration to support connection with a RS 232 422 485 device Definition of DIP Switches No Dip description Default 1 ON Console OFF Data OFF 2 RS 232 ON 3 RS 422 485 4W OFF 4 RS 485 2W OFF 5 NA OFF 6 NA OFF 7 TMR Terminator OFF For setting the
10. number Byte counts from UART Byte counts to network Byte counts from network Byte counts to UART RS232 422 485 Transfer Configuration Server Client Type SERUER ICP Port Number 1235 Serial Port Configuration Operation Mod Baud Rate Parity Word Length Stop Bits Flow Control NONE lt Tab gt to move lt Enter gt to select Monitor Menu Firmware Upgrade Menu From this menu the user can upgrade the existing firmware to newer firmware available from a TFTP server Simply enter the file name of the updated firmware in the file name field and enter the IP address of the TFTP server in the IP address field to perform the upgrade Selecting lt update gt will start downloading the newer firmware and system will restart to apply the firmware TFTP Firmware Upgrade menu 30 SNMP Configuration Menu Use the SNMP Configuration screen to display and modify parameters for the Simple Network Management Protocol SNMP The Device Server includes an onboard SNMP agent that monitors the status of its hardware as well as the traffic passing through its ports A computer attached to the network called a Network Management Station NMS can be used to access this information Community strings control access rights to the agent module To communicate with the Device Server NMS must first submit a valid community string for authentication The options for configuring community strings and relate
11. 32V DC 800mA Frequency 47Hz to 63Hz Temperature Operating 0 C to 50 C Relative Humidity 10 to 80 non condensing Storage 20 to 80 C Relative Humidity 5 to 90 non condensing Emissions FCC Part 15 of Class A amp CE approved Dimensions 109 2 x 90 x 30mm L x W x H Weight 280 grams Package Contents The package should include the following One RS 232 422 485 to 10 100 Base TX Device Server unit One power adapter please check connector type and input power specification Four self adhesive pads DIN Rail Kit Screws for wall mount installation User s Manual CD Serial IP Redirector software CD 2 Hardware Description Product Overview The Device Server features complete Ethernet and TCP IP network support that allows devices in industry with RS 232 422 485 connectors such as milling machines measurement instruments and robots to connect to LAN based automation Other devices typically found on campus networks such as card readers code readers lab equipment medical equipment and other similar serial devices can now instantly migrate to a TCP IP network Additionally by deploying the device server enable users to monitor and manage up to 256 serial devices from single PC with the help of Serial IP Redirector software Product Illustrations RS 232 422 485 LEDs Serial Port RJ 45 Front panel DIP Switches Power Power LED Connector Rear panel 3 Installation To in
12. IP address at web browser 192 168 0 254 if connecting with default IP A window will be prompted to Enter user name and password 6 Connect to 192 168 0 200 MN Web Manager User name admin a Password Remember my password Note We use IP 192 168 0 200 to write this manual 22 After successful login select System Info option and following window will appear Edit the required parameter and press Apply to save Description Model Name Up Time IP Address Subnet Mask Gateway System Information Serial IP Device Server RS 232 To ETH Device Server Oday 6 hour 51 min 24 sec 192 168 0 200 255 255 o 0 If 23 6 Management Via Menu Driven Console Port amp Telnet The figure below shows the Main Menu screen From this screen the configuration options available provide the user to quickly access and adjust the device server settings as required Main Menu DHCP Configuration Menu RS232 422 485 Configuration Menu Monitor Menu Firmware Upgrade Menu SNMP Configuration Menu System Restart Menu Exit lt Tab gt to move i lt Enter gt to select Main Menu Screen Use TAB key to move the cursor to different fields and press Enter to select edit the option 24 System Information Menu From this menu the user can view some system related information and default IP addr
13. LONGSHINE Longshine Technologie Europe GmbH LCS C844 Device Server www longshine de RS 232 422 485 to 10 100Base TX Device Server User s Manual COPYRIGHT All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means whether electronic mechanical photo copying recording or otherwise without the prior written permission of the publisher many ay FCC WARNING N Fe gt us This equipment has been tested and found to with the limits for class A device pursuant to part 15 of FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense This is Class A product In domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Take special note to read and understand all content given in the warning boxes AA Warning Table of Contents 1 Introd ction te coii iiec e aoc anna cune nain
14. ce RS232 422 485 Connection Status Connect Status Server Type Peer IP Address 192 168 0 21 Dest Srce Port Number 1753 1234 Byte Counts From UART 543 Byte Counts To Network 543 Byte Counts From Network 9 Byte Counts To UART 9 User can get the instant information about the connectivity Connect Status Server or Client Peer IP Address of remote PC access the serial device via Device Server Dest Srce Port Number Showing the destination and source Port numbers Source port number will be as configured Byte Counts From UART Displaying the number of bytes transmitted from serial device 40 Byte Counts to Network Displaying the number of bytes received to TCP IP network Byte Counts From Network Displaying the number of bytes transmitted from Network Byte Counts to UART Displaying the number of bytes received to serial device Mgmt Configuration This category offers multiple management options User Config This option will allow user to change the username and user password for the device server management User Configuration User Name User Password admin Type the new user name in the User Name and password to User Password Selecting Apply will implement the new user name and password which will be required to manage the device server Warning It is recommended to keep a written record in a safe place for the User Name and Password In case you los
15. control function of the serial port see the table below DIP 1 Serial Connection ON RS 232 Console OFF Data Communication NOTE 1 If using console mode turn the DIP Switch 1 to ON position For data communication from the serial device keep the switch to OFF position In case of ON position data communication will be blocked and at OFF position console port access 2 For some RS 422 485 devices which may not be designed to provide DB 9 connection please check the pin definition to connect the devices 3 For the first time installation you have to use console mode to setup the IP and TCP port configuration with RS 232 cable 15 Always use Cross Over cable if using Straight Through you must use Null Modem to use Telnet option 16 4LED Indicators This Device has LED indicators located at the front of the device The LEDs have been designed to give easy at a glance network status and provides real time connectivity information Please see below for an interpretation of their functions LED Indicators LED Condition Status Device Server is receiving PWR On Green power Off Power off or failure Illuminated when RJ 45 On Green connector attached and link signals received ACT 4 RJ 45 Flashing Data traffic passing through Green RJ 45 port Off No link established On Green RJ 45 port in 100Base mode 100
16. d trap functions are described in the following figures and tables SNMP Configuration System Name RS 232 422 485 To ETH Device Server Locati Contact name Get Community public Set Community public SNMP Trap Index Status IP address Community public Enabled 192 168 8 188 Disabled 8 8 8 8 4 2 3 Disabled 8 8 8 4 Disabled 8 8 8 5 Disabled 8 8 8 8 8 8 public lt lt Tab gt to move i lt Enter gt to select i lt Esc gt to Cancelgel SNMP Configuration 31 Use the lt Tab gt and lt Enter gt keys as previously Enter the IP address of computers for when abnormalities on a connection occur and an alarm to be sent Enter their community names and disable or enable their alarm function accordingly See descriptions below Parameter Description Index Number assigned to each trap Status Disable or enable their alarm function accordingly IP Address Enter the IP address of computers for when abnormalities on a connection occur and an alarm to be sent Enter their community names and disable or enable their alarm function accordingly Community Enter their community names You can use an external SNMP based application to configure and manage the Device Server This management method requires the SNMP agent on the Device Server and the SNMP Network Management Station to use the same community string This management method in fact uses two community strings the get community string and the set
17. ess The user should set up appropriate IP address subnet mask and Gateway for his own network After entering a new IP address Telnet and data communication will be based on the new address System Information Description Serial IP Device Server Model Name RS 232 422 485 To Device Server Company Name Board Name 6700 00633 0100 MAC 1 Address 80 08 84 91 88 01 DHCP Client Disabled IP Address 2 Subnet Mask Gateway 192 168 0 1 lt SAUE gt lt Tab gt to move i lt Enter gt to select System Information menu Once changes are made move the cursor to lt SAVE gt by using TAB key and press Enter to save the settings Change of IP will lead to restart the Device Server Note In Telnet mode you can t change the IP address 25 DHCP Configuration Menu DHCP Dynamic Host Configuration Protocol allows the Device Server to obtain an IP address from DHCP server automatically NOTE A DHCP server must exist and be available in your local network prior to enabling the DHCP client DHCP Configuration menu Use Spacebar to enable the DHCP Client settings Select lt SAVE gt to apply the settings and lt ESC gt to move to the previous menu If you don t want to save the changes made just select lt ESC gt and you will move to previous menu without making any changes RS 232 422 485 Transfer Configuration The RS 232 422 485 menu is applicable to all RS 232 RS 422 RS 485 mode
18. f duplex asynchronous serial data transmission RS 485 e Supports serial port asynchronous data rates up to 115 2 Kbps e Extended distances up to 1 2 km 24 AWG using RS 422 485 e Auto detecting 10 100 Mbps Ethernet interface Terminator feature improves signal quality and distance LEDs for at a glance device status Wall mount or Din Rail mountable installation Power range 9 32V DC FCC Class A amp CE approved Specifications Standards Ports Max Distance Data Rates Signals Configuration IEEE 802 3 10BASE T Ethernet IEEE 802 3u 100BASE TX Fast Ethernet EIA TIA RS 232 422 485 EIA TIA 574 UTP 100 120 RJ 45 type 1x 9 pin serial connector D sub Male UTP 100 meters Cat 3 4 5 Serial 15 meters RS 232 1 200 meters RS 422 RS 485 UTP 10 or 100 Mbps Serial 115 2 kbps asynchronous RS 232 TxD RxD CTS RTS DTR DSR RI DCD GND RS 422 TxD RxD GND RS 485 Data Data GND Bits Per Second 38400 Parity None Data bits 8 Stop bits 1 Flow Control None The console connection is only available once the DIP switch 1 is ON Switches Power Environment DIP 1 Enables disables console data communication mode DIP 2 Enables disables RS 232 DIP 3 Enables disables RS 422 485 4 wire DIP 4 Enables disables RS 485 2 wire DIP 5 N A DIP 5 N A DIP 7 Enables disables termination TMR External power adapter 9
19. fer mode DIP Switch 2 3 and 4 are correctly selected as per the serial device attached Once the link is established you can manage the serial device attached to the device server from remote workstation installed Serial IP Redirector software From the Serial IP Port Monitor option you can see the connectivity status and IP address of the device server amp SeriaUIP Port Monitor 4 3 2 Jog File Edt Help Activity Trace Port Status IP Address COM3 Connected 192 168 0 200 COM4 If more devices are attached and connected the status and IP address of those devices will also be showed against each Virtual COM port as shown below 49 Pot Status iPAddes M Connected 192 168 0 200 com Qi Connected 192 168 1 200 coms 50 51
20. king on the Restore button will set the device server back to factory defaults All saved configurations will be lost 45 Appendix Serial IP Redirector Install the Serial IP Redirector software from CD Rom Once it s installed you can read the documentation to get assistance related to Serial IP Redirector The documentation will be installed to your PC with the software The serial IP icon can be found at the right corner of system tray Right click the icon and select Configure the following window will appear mm IP Address Port Number Connect to server Accept Connections Select Ports Configuration of COM3 User Please select the COM ports m you would like to redirect to 4 JCOM5 COME com COMS 1 10 Me COM11 COM12 OK Cancel Help Bes Be ey Licensing Advanced Close Help About 46 Click on Select Ports option to configure the Virtual COM ports You can select up to 256 virtual COM ports COM1 and COM2 are normally physical ports so will not appear here The selected ports will be shown on the left top corner of the Configure screen Selecting the Connect to server will allow you to enter IP address and port number Enter the correct IP address and port number assigned to the Device
21. or the Device Server are public and private respectively SNMP Communities SNMP Communities Community Name GET public SET private needed assign the new parameters and press Save to implement the settings IP Trap The following figure and table describe how to specify management stations that will receive authentication failure messages or other trap messages from the Device Server Up to 5 trap managers may be assigned 43 Trap Manager IP Address Community Name Status 192 168 0 59 public Enabled 192 168 1 112 private Disable 0 0 0 0 public Disable 0 0 0 0 public Disable v 0 0 0 0 public Disable Click on each parameter field to modify the desired setting then click on Undo to restore previously saved configurations or click on Save to retain newly entered information See descriptions below Parameter Description Enter the IP address of terminals for when abnormalities on a connection occur and an IP Address alarm to be sent Enter their community names and disable or enable their alarm function accordingly Community Enter their community names Name Status Disable or enable their alarm function System Restart Menu Users can restart reset the system via software from a remote location Restart Options 44 System Restore Factory Default Settings Restore the factory default settings of the Device System Reset Press Reset if the device is abnormally functioning A Clic
22. reen Firmware version 1 00 02 built at Jan 9 2006 11 16 19 Press ENTER key to start 4 Press ENTER and on the following screen type the default username admin leave the password field blank since there is no default value and press ENTER to proceed Firmware version 1 88 82 built at Jan 9 2006 11 16 19 Press lt ENTER gt key to start Username admin Password 5 Select either CLI User Interface or Menu driven Interface option by using the associated number key or using the TAB key and pressing ENTER A relevant Main Menu screen appears 19 lt 1 gt CLI User Interface lt 2 gt Menu Driven Interface The Device Server is preset with a factory IP address 192 168 0 254 that must be configured to the user s individual IP address It is important to do this so that the device server doesn t conflict with other devices with the same defaults NOTE Prior to following the instructions for HyperTerminal Configuration ensure that a serial cable connection between the device server and workstation exists Type the following command line to change the device IP address in CLI mode where xxx s represent values between 0 and 254 and the user should enter their own IP address in this form a set ethO If using the Menu driven interface Select the System Information from the Main Menu and following screen will appear Use TAB key to move the cursor and 20
23. ring is situated towards the top Attaching the Device Server to the DIN rail is easy just align and attach the top rail then press down and snap forward the Device Server to snap in the bottom rail as shown in the figures below Use following steps set up the Device Server metal spring x DIN Rail e The surface must support at least 500 gm for the Device Server e The power outlet should be within 1 82 meters 6 feet of the Device Server e Visually inspect the power adapter and make sure that it is properly connected Make sure that there is proper heat dissipation from and adequate ventilation around the Device Server Do not place heavy objects on the Device Server A Warning Please exercise caution when using power tools Also install this unit away from damp or wet locations or in close proximity to very hot surfaces These types of environments can have a detrimental effect on the unit and cables 11 Powering On Unit The Device server uses external power supply 9 32V 0 8A 50 60 Hz 1 Insert the power cable plug directly into the receptacle located at the back of the device 2 Plug the power adapter into an available socket 3 Check the rear panel LEDs as the device is powered on to verify that the Power LED is lit If not check that the power cable is correctly and securely plugged in Note For International use you may need to change the AC power adapter cord You
24. s Before using data 26 transfer mode option for the Device Server move the DIP Switch 1 to OFF position You can assign the port number to monitor and access the serial device via device server over the network Internet from a workstation using Serial IP Redirector software The TCP port number can be of any number from 1024 to 65535 RS232 422 485 Transfer Configuration Server Client Type SERVER Port Number 1234 Packet Mode lt serial gt Enable Packet Mode timeout lt ms gt 3 lt SAUE gt lt ESC gt Packet Timeout is between 1075000 lt Esc gt to cancel lt Enter gt to select RS 232 422 485 Transfer Configuration In case you are using a Serial device with 2 wire RS 485 application or Modbus RTU protocol do not forget to Enable Packet mode of serial input Also put appropriate inter packet timeout value to allow the smooth data communication To add the time out value via console mode first Enable the packet mode and Save the settings Once settings applied you will be able to change the timeout value 27 Warning Changes to the settings are saved to a system flash memory and do NOT take effect until a system reset or reboot has occurred This action validates the new settings 28 Monitor Menu This screen provides at a glance system status information Connection Status Connect Status Not connected Peer IP Address 8 8 8 8 Dest Srce port
25. stall your Device Server please see the following procedures e Location e Desktop Installation e Powering On Unit e Connecting Copper Cables 089 Male Connector Pin Assignment e Serial Connection e Ethernet Connection Location The location selected for installing the Device Server may greatly affect its performance When selecting a site we recommend considering the following rules 1 Install the Device Server in a fairly cool and dry See Technical Specifications for the acceptable temperature and humidity operating ranges 2 Install the Device Server in a location free from strong electromagnetic field generators such as motors vibration dust and direct exposure to sunlight 3 Leave at least 5cm of space at the front and rear of the unit for ventilation 4 Affix the provided rubber pads to the bottom of the Device Server for grip and to protect the case from scratching Wall Mount Installation The Device Server can also be installed by wall mounting The backside casing provides space for two screws each side Identify the exact location at wall by placing the Device Server and marking the screw positions Use the screw include in the package and snug them well to fix the Device Server Din Rail Mount Installation The aluminum DIN Rail attachment plate should already be affixed to the back panel of the Device Server If you need to attach the DIN Rail plate assure that the stiff metal sp
26. t the both or either one you need to reset the system to default setting This can be done by pressing a button at S1 location of PCB near to capacitor after removing the casing 41 Firmware Download The user can download the newer latest firmware to upgrade the device server once available The user has two options either they can upgrade via HTTP with browse option to select the firmware file Upgrade System by HTTP File Name Start Upgrade by HTTP Upgrade System by TFTP IP Address File Name Start Upgrade by TFTP If using TFTP method user must provide the valid IP address of TFTP server and the file name i e VK413 bin Once enter the parameters press Start Upgrade by HTTP TFTP to upgrade the firmware The window will appear to show the time to before restarting the device server to implement the upgraded firmware SNMP Config You can use an external SNMP based application to configure and manage the Device Server This management method requires the SNMP agent on the Device Server and the SNMP Network Management 42 Station to use the same community string This management method in fact uses two community strings the Get community string and the Set community string If the SNMP Network Management Station only knows the Set community string it can read and write to the MIBs However if it only knows the Get community string it can only read MIBs The default Get and Set community strings f
27. tings 36 set idle time in seconds set automatic logout when the program or communication is idle set xfer the command is for RS 232 configuration and data communication setting The command syntax is as below set xfer arg_1 data_1 arg_2 data_2 arg n data n Argument List Port Set TCP port number statistics Clear statistics upgrade Use this command to upgrade the firmware i e upgrade firmware Soft2 bin set snmp Use this command to set SNMP settings of the device server Warning After each configuration session be sure to set DIP switch 1 to the OFF position Otherwise the device server will not transmit any data Web Browser Interface 37 Please see the topic Web Access in previous chapter to log in the Device Server via web browser Once you logged in the following main screen will appear E http 192 168 0 200 Microsoft Internet Explorer BAX File Edt View Favorites Tools Help ay fers O Z 5 Address http 192 168 0 200 Go Links 10 100 RS 232 422 485 To ETH Device Server System Information Description Serial IP Device Server Model RS 232 422 485 To ETH Device Server Up Time 0 day 0 hour 36 min 34 sec IP Address 192 168 0 200 Subnet Mask 255 255 0 22 le le le Gateway 192 168 jo 1 le le le
Download Pdf Manuals
Related Search
Related Contents
TMDB System User Manual (Registrar) Manuale d`uso IT - Green Economy Srl Samsung CLX-3300 Felhasználói kézikönyv UNEPLAS GEL AGUA POTABLE 福岡大学薬品管理システム運用マニュアル A-854 RevC AutoAdjust LT - Impact Biomedical oxygen concentrator 7890 Basic Troubleshooting.book Unter uns Entre nous Leapfrog Hydro Documentation Copyright © All rights reserved.
Failed to retrieve file