Home

Omnitron miConverter GX/T

image

Contents

1. F O AN a Port configured for F O Auto Neg reen manual negotiation Blinking 1Hz Configured as AN but linked in Manual mode F O Activity Synchronized Blinking 1Hz Green NA AN error or Remote Fault bit F O AN detected lon UTP port linked at 100Mbps UTP Activity FOOTING Green No activity Blinking 10Hz Link activity at 100Mbps lon UTP port linked at 1000Mbps UTP Activity E 4000 Link actt Green No activity Blinking 10Hz Link activity at 1000Mbps Teo lon UTP port linked at 10Mbps 10 Link Act Green No activity Blinking 10Hz Link activity at 100 1000 koMops Page 8 SPECIFICATIONS Model miConverter GX T Description 10 100 1000BASE T UTP to 1000BASE X Fiber Converter Power Requirements DC Power Typical DC Power Connector Protocols 10BASE T 100BASE TX 1000BASE T 1000BASE X Frame Size 10 240 byte max frame size Cable Types UTP EIA TIA 568A B Category 5 and higher Fiber Multimode 50 125 62 5 125 100 140 um Single mode 9 125 um Connector Types UTP RJ45 Fiber Dual Fiber SC ST Single Fiber sc SFP LC LED Display Pwr AN F O Lk UTP 10 UTP 100 UTP 1000 5 to 12VDC 0 35A 5VDC 2 5mm DC Jack or 2 Pin Terminal Connector AC Power Adapter US AC Power Adapter Universal or Country Region Specific 100 120VAC 60Hz 0 02A 120VAC 100 240VAC 50 60Hz 0 02A 120VAC
2. up position before insertion 5 Mount the miConverter GX T using the included Velcro strips or optional wall mounting bracket kit P N 1091 0 6 To power the unit using the AC DC adapter connect the AC DC adapter to the AC outlet Then connect the barrel plug at the end of the wire on the AC DC adapter to the 2 5mm DC barrel connector center positive on the unit Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit To power the unit using a DC power source prepare a power cable using a two conductor insulated wire not supplied with a 14 AWG gauge minimum Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cables to the GX T unit by fastening the stripped ends to the DC power connector Connect the power wires to the DC power source The Power LED should indicate the presence of power WARNING Note the wire colors used in making the positive and negative connections Use the same color assignment for the connection at the DC power source Page 4 LED INDICATORS Ean Color Off State On Blinking State Power Green No power Power pi lon Module has power lon UTP port linked at 1000Mbps Fiber Activity Blinking 10Hz Link activity at Green No actvity F O Link Act HOOOMbps Blinking 1Hz Energy detected On Fiber port configured for AN
3. Fiber Optic link LED does not illuminate after installation is complete Possible Causes A Confirm that the fiber optic cable is properly connected to the miConverter GX T and the remote fiber optic device B Confirm that the fiber cable type matches the fiber transceiver type multimode single mode on the miConverter GX T C If using a dual fiber model confirm that the transmitter Tx is attached to the receiver side of its link partner and that the receiver Rx is attached to the transmitter D If using a single fiber model confirm that the Tx wavelength on the miConverter GX T matches the Rx of the connected fiber optic device Page 11 Page 15 Problem The UTP link LED does not illuminate after installation is complete Possible Causes A Confirm that the UTP cable is connected properly to the miConverter GX T and the attached UTP device B Confirm that the UTP cable pin out is correct EIA TIA 568 A C Verify the miConverter GX T UTP port is configured with the proper settings based on the attached device AN or MAN 1000 100 or 10 HD or FD Note If corrective actions do not resolve your situation please contact Omnitron Systems Technical Support Page 12 TECHNICAL SUPPORT For help with this product contact Omnitron s Tech Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology 500 Irvine CA 92618 USA E mail support o
4. SPECIFICATIONS CONT Dimension W 1 71 x L 4 10 x H 0 84 Weight without power adapter 5 oz with USB power adapter 6 oz with AC power adapter US 12 oz Compliance Operational Temperature Standard 0 to 50 C Storage Temperature 50 to 80 C Humidity o non condensing S10 95 Altitude 100m to 4000m MTBF hrs without power adapter 878 000 with US or Country Region Specific 250 000 power adapter wiin 100 000 Universal power adapter Page 9 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS Or you may register your product on the Internet at http www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron
5. designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Page 13 Page 10 Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory Page 14 TROUBLESHOOTING GUIDE Problem The Power LED does not illuminate after installation is complete Possible Causes A Confirm that the power supply is connected B Confirm that the correct power supply is being used Problem The
6. k Propagate a port transmits a Link signal only when receiving a Link at its other port For example the UTP transmits a Link only when receiving a Link at the fiber port Fig 2 c Page 5 Ci tor T ason PN E r e iasan SM SF SM SF eee SM SF When choosing power options replace x in the model number with the suffix number that corresponds to the selected power supply ae _ Pees aons m saan 1310 1550 US Power Supply 120Volt 60Hz Universal Power Supply requires AC power cord 100 240Volt 50 60Hz European Power Supply 100 240Volt 50 60Hz UK Power Supply 100 240Volt 50 60Hz Australian Power Supply 100 240Volt 50 60Hz USB Power Adapter Cable US JPN Power Supply 100 240Volt 50 60Hz 2 Pin Terminal Connector Example 1223 3 6 SM DF 80KM with a USB Power Adapter Cable For power supplies 3 4 5 and 8 country region specific clips are used to provide the necessary power connection Single Fiber converters must be used in pairs The Tx wavelength on one end has to match the Rx wavelength on the other Page 2 LS LS ue Fiber gt O rO A Fib UTP oW kg fiber ole Switch 1 Converter A ConverterB Switch 2 LS LS gt gt R gt B j4 O O Switch 1 Converter A ConverterB Switch 2 LP LP gt gt x gt g C j4 eo we Switch 1 Converter A LEDLit X LED Off Fig 2 Li
7. mnitron systems com URL http www omnitron systems com Form 040 12200 001A 9 08 Page 16
8. ngth must match the Rx wavelength at the other end and Page 3 UTP UTP Mode 1 Mode 2 Configured for Auto Negotiation Down 1000F 1000H 100F 100H 10F 10H and Pause capable Down Manual 10M FDx Up Down Manual 100M HDx Up Manual 100M FDx When the module is configured for auto negotiation the module will advertise in the order shown in the parenthesis UTP Mode of Operation F O Manual Auto Man AN DIP Switch Setting this DIP Switch to Auto Negotiate AN factory setting enables the fiber port to determine duplex mode automatically If a connection can not be established the fiber port will automatically attempt to connect to the device by reconfiguring to manual mode If the connected device cannot provide the proper signal to indicate its own mode of operation or the fiber port can establish a link after attempting a manual connection this DIP Switch should be set to Manual Man This feature allows connections with legacy devices that do not support auto negotiation NOTE When the fiber port is configured for Manual Mode a link may not occur with the connected device Configure both devices to Manual mode to establish a link Page 7 the Rx wavelength must match the Tx wavelength at the other end 4 When using a GX T SFP model insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the GX T NOTE The release latch of the SFP Fiber transceiver must be in the closed
9. nk Modes Converter B Switch 2 UTP Mode Configuration DIP Switches See the table on page 7 When configured for auto negotiation Pause is always advertised Each port will resolve Pause capability independently during auto negotiation If NO Pause is resolved the port will not send or respond to Pause frames Page 6 WARNING Before inserting the Power Adapter verify that the power on the adapter is appropriate for your AC line voltage source POWER ADAPTER NOTICE This product should only be used with Omnitron supplied Power Supply model numbers 9113 PS 9115 PS 9116 PS 3 9116 PS 4 9116 PS 5 or 9116 PS 8 When powering the miConverter GX T using the USB Power Adapter cable P N 9130 2 the cable must be connected to a Full Powered USB Type A port 5V 500mA Note Not all USB Type A ports are Full Powered USB ports INSTALLATION PROCEDURE 1 Configure the appropriate miConverter GX T DIP Switch settings 2 Connect the UTP port via a Category 5 or better cable to a 10BASE T 100BASE TX or 1000BASE T Ethernet device 3 When using fixed fiber port models connect the appropriate multimode or single mode fiber cable to the fiber port of the installed module It is important to ensure that the transmit Tx is attached to the receive side of the device at the other end and the receive Rx is attached to the transmit side Single fiber SF media converter models operate in pairs The Tx wavele
10. osr Omnitron Systems Technology Inc miConverter GX T Media Converter User Manual Unit shown with optional wall mounting bracket kit DESCRIPTION The miConverter GX T is a 10 100 1000BASE T UTP to 1000BASE X fiber media converter that supports jumbo frames up to 10 240 bytes The GX T features fixed fiber and Small Form Pluggable SFP transceivers that support multimode single mode and single mode single fiber options Both the fiber port and the UTP port support auto negotiation an IEEE standard which defines how all the communicating devices automatically perform their configuration functions The auto negotiation feature can be disabled on both ports for manual configuration using DIP switches on the product This is useful in a situation where the GX T is connected to a non negotiating device and the configuration parameters must be set manually Page 1 DIP SWITCH SETTINGS Link Propagate LP UTP Mode 1 m UTP Mode 2 UP m F O Manual Negotiate Man i 4 OOL DOWN L F O Auto negotiate AN UTP Mode 2 UTP Mode 1 Link Segment LS Fig 1 DIP switches Link Segment Link Propagate LS LP DIP switch Setting the DIP switch to LS Link Segment a port transmits a Link signal independently of any received Link at any other port For example the UTP transmits a Link regardless of the fiber receiving a Link Fig 2 a amp b Setting the DIP switch to LP Lin