Home
Omnitron iConverter 1-Module Redundant
Contents
1. locate the DC circuit breaker and switch the circuit breaker to the OFF position Prepare a power cable using a three conductor insulated wire not supplied with a 14 AWG gauge Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cables to the chassis by fastening the stripped ends to the DC power connector Page 8 Figure 4 48 VDC and AC DC Redundant Power Configuration WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to the circuit breaker and switch the circuit breaker ON Confirm that the unit has powered up properly by checking the power status LED located on the front of the installed chassis See Section 3 2 for the details concerning the operation and definition of the front panel LEDs Page 9 3 1 4 Power over Ethernet PoE Option On models with the PoE feature see Table 1 UTP PortA the left port on the front of the chassis can be configured as a PoE Powered Device PD It accepts power from a UTP based Power Sourcing Equipment PSE and supports the following PoE standards 1 IEEE 802 3af 2003 Alternative A power over data wires 2 IEEE 802 3af 2003 Alternative B power over spare wires 3 Pre Standard Cisco PoE power over spare wires with reversed polarity older Cisco switche
2. please consult the specific module s user manual Page 5 3 0 CONFIGURATION 3 1 Redundant Power Configurations The chassis support multiple redundant load sharing power configurations The power is connected to the back of the chassis with connectors labeled Pwr1 and Pwr2 Pwr1 is the primary power connection and Pwr2 is the backup There are four primary power options and two backup options The combinations of primary and backup power include low voltage barrel connector low voltage terminal high voltage terminal and PoE from the UTP ports The manner in which the power is connected will depend on the model selected Refer to Table 1 for the specific power input options supported on each chassis model 3 1 1 AC DC Power Option Low Voltage Barrel To power the chassis using AC DC adapter connect the AC DC adapter to the AC outlet Then connect the barrel plug at the end of the wire on the AC DC adapter to the 2 5mm DC barrel connector on the chassis A wire saddle is located below each barrel connector to secure the power line and prevent accidental removal Repeat the process if the chassis was ordered with the additional low voltage barrel option Figure 2 Redundant AC DC Configuration Note The chassis must be used with an Omnitron supplied AC DC Power Adapter Confirm that the unit has powered up properly by checking the power status LED located on the front of the chassis See Section 3 2 for
3. consequential damages whether based on contract tort or any legal theory Page 25 7 0 TECHNICAL SUPPORT If you encounter problems with this product contact Omnitron Technical Support Phone 1 800 675 8410 USA 1 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 Email support omnitron systems com URL http www omnitron systems com Form 040 8245 001D 10 07 Page 26
4. CN Omnitron Systems Technology Inc iConverter 1 Module Redundant Chassis User Manual 140 Technology 500 Irvine CA 92618 Phone 949 250 6510 Fax 949 250 6514 Table of Contents INTRODHGCTION geesde EEN 3 General Description cccecccsseeecesseeeeeseeeeeesseeeeesesaeeenseeeeeeneeeeeees 3 About This Manual eceecee eee ee eee eee een eenneenseeneeneeaeeeeeeeees 3 Chassis Model Numbers ccccsseceeeseeeeeseeeeeeeeeeseeeeeeeeesneeeeneees 4 INSTALLATION eege 4 Chassis Installation ccccessssseeeeeeeseeseeeeeeeesneeeeeeeeeesseeseeneees 4 Module Installation c cccccsssccceeeeseeeeeeeeeeeseeeeeeeeeeeeneeseeeeeeenaes 5 Fiber Installation esanian 5 CONFIGURATION cise Assis EEeeeegengeb ges aaaea aaa aaa 6 Redundant Power Configurations cccssscceeseeeeseeeeeeseeeneeeees 6 AC DC Power Option Low Voltage Barrel ccsssseeerees 6 24 VDC Option Low Voltage Terminal ccsccsssseeesseeseeeeees 7 48 VDC Option High Voltage Terminal cssseeeesseeseeeeeees 8 Power over Ethernet POE Option ccssssseceeeeeseeseeeeees 10 LED INGIGALONS sessiic ce ccscedesitetecclinetes eect a 11 Contact Closure Sensors cccseecsssseeeeeseeeeeseeeeeeseeeeeeseneeenseeneess 12 Ethernet Backplane ccccsseeeeeseeeseseeeeeesseeeeenseeeseseeeeeesseeneeeeas 14 CHASSIS MANAGEMENT 2 ccseeceeeeeese
5. Terminal DC Terminal RJ 45 DC Barrel DC Terminal Closure Ports 9 24V 9 24V 24 60V POE 9 24V 9 24V 8245 111 x Two US 8245 112 x Two Univ 8246 111 x Two US 8246 112 x Two Univ 8246 511 One US 8246 512 One Univ 8247 111 x Two US 8247 112 D Two Univ 8247 121 x One US 8247 122 x One Univ 8247 312 One Univ 8247 320 8248 111 x Two US 8248 112 x Two Univ 8248 121 x One US 8248 122 x One Univ 8248 220 8248 311 Two US Two Univ x x x x x x x 8248 312 x 8248 320 8248 511 x x x x x x x x x x x x x One US x x x x x x x x x x x x x x x x x x x 8248 512 3248520 One Univ EE Jo ee E Jo T fJ Oo Jo T fJ Oo o Jo T fJ ee Oo J Teef gt Oo J EC gt Oo Jo T fJ ee Oo o Jo T fJ ee RSC oo T S eee Oo Jed J gt E ee J gt Oo Jeo T J ee Oo o Jo T f gt Ooo ST T f gt Oe oo T S ee EE e ee Oo Jee J gt Oo Jeo T J Oo SJ Tef gt Oo o J Tef gt Oo d Te Table 1 Chassis Model Numbers 2 0 INSTALLATION 2 1 Chassis Installation The iConverter 1 Module Redundant chassis is designed to accommodate wall mount or tabletop installations For wall mounting the 8249 0 iConverter Wall Mount kit sold separately is designed to attach the chassis to a wall backboard or other flat surface For tabletop installations place the unit on a flat level surface Attach the rubber feet to the bottom of the chas
6. VDC 0 27A 48VDC RJ 45 IEEE 802 3af 2003 Alternative A amp B Pre standard Cisco PoE 100 120 VAC 60Hz 0 2A 120VAC AC Power Adapter Universal 100 240 VAC 50 60 Hz 0 2A 120VAC L H 5 4 W x 6 8 L x 1 0 H without power adapter 1 5 Ibs Table 7 Model Specifications o 5 D a d iw O v S bd g QO bei 3 bd Q bei 3 High Voltage DC Power Connector PoE Connector AC Power Adapter US Refer to Table 1 for applicable product features Page 23 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Caution All user required operations can be performed without opening the unit Never attempt to open or remove the cover or tamper with the unit There are no user replaceable or serviceable parts in this unit Equipment is not intended to be installed and used in a place home school or public area accessible to the general population Page 24 Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days fro
7. atus of the module The screen displays the model and serial numbers hardware and software revisions as well as the condition of the LEDs Alarm Indicators and DIP switches The DIP switches 1 4 correspond with the physical switches on the back of the chassis These switches can be changed from the Module Screen by selecting the appropriate switch number DIP switches 9 75 can only by configured from the Module Screen options Select the appropriate option to change the DIP switch setting Module Screen iConverter 1 Module Redundant Identifier Switch ON Condition OFF Condition LY Alarm 1 Enable Alarm 1 Disable Alarm 2 Enable Alarm 2 Disable Alarm 3 Enable Alarm 3 Disable Alarm 4 Enable Alarm 4 Disable ot Available ot Available ot Available ot Available Soft Switch ON Condition Off Condition os Port A Manual Port A AN Mode Port A 10 Mbps Port A 100 Mbps Port A HDX Port A FDX Port B Manual Port B AN Mode Port B 10 Mbps Port B 100 Mbps Port B HDX Port B FDX Pause Enabled Pause Disabled ot Available Toggle Switch 1 16 S tatus Port C tl1 gt Figure 10 Module Screen Showing DIP switches Only Page 18 The Module Screen also provides access to the status and control screen To select the Status Screen enter S Module Screen iConverter 1 Module Redundant Identifier Chassis Number 7 Slot Number 2 Model Number 8248 512 Serial Number XXXXXXXX Manufacturing Date XXXXXXXX Product R
8. e following pin configuration en ES ri Sensor 3 Alarm Table 5 Contact Closure Sensors Pinout Configuration Page 13 3 4 Ethernet Backplane The chassis contains two Ethernet backplane buses A and B that operate at 10 100Mbps Both buses are enabled by default When an iConverter module that features Ethernet backplane connectivity is installed in the chassis the A bus connects directly to UTP Port A and the B bus connects directly to UTP Port B as shown in Figure 6 Inserted Module Ethernet Switch Backplane B Backplane A Figure 6 Backplane Connectivity The data traversing across the Ethernet backplane can be controlled by configuring the installed iConverter module See the specific iConverter module s User Manual for additional details Page 14 4 0 CHASSIS MANAGEMENT 4 1 Overview The 1 Module Redundant chassis features configurable options and status information depending on the model Configurable parameters and status information available through the serial console port on the installed iConverter Management Module are e Contact Closure Alarm notification Enable disable physical DIP switches e Port A B Control UTP auto negotiation 10 100 and Full Half Duplex e Pause Control Enable disable e Port Access Control Enable disable e Power Supply 1 2 Voltage current and temperature 4 1 1 Configuring and Monitoring the C
9. eeeeeeseeeeeeeeeseeeeeeeees 15 EVEN EE 15 Configuring and Monitoring the Chassis ccssessseeeees 15 APPLICATIONS E 21 Battery Backup with Alarms cccccssseeeessseeeeeeseeeeseeeeesseeeeeeeees 21 Contact Closure Sensor Configuration cccssseeeeeeeeeeeeeees 22 SPECIFICATIONS sic ccstccecssacesszentsccecsadvewecevaccertetescdacscnuevestedereeeste 23 TECHNICAL SUPPORT c cccsssccseecessecenssrestecssnecenseesseceneeeenanse 26 Page 2 1 0 INTRODUCTION 1 1 General Description The iConverter 1 Module chassis features a number of redundant power inputs UTP port and alarm options It supports primary and secondary power input options and variety of power connection types By utilizing the optional UTP ports the unit can be powered from a connected Power Sourcing Equipment PSE Optional contact closure sensors are provided for connection to external alarm indicators By installing a managed iConverter module into the chassis the chassis functions can be remotely managed by Telnet and SNMP software such as Omnitron s NetOutlook Management software 1 2 About This Manual This document supports release 1 1 of the iConverter 1 Module Redundant chassis iConverter management module and NetOutlook must be at version 3 3c or higher Page 3 1 3 Chassis Model Numbers Primary Power Backup Power Two UTP Low Voltage Low Voltage High Voltage Low Voltage Low Voltage Contact RJ 45 DC Barrel DC
10. evision x Software Revision Xex P1 Volts 0 0 V P2 Volts Pl Current 0 0 A P2 Current Temp 113 F 45C PoE Installed Fan Not Installed Alarm Alarm Alarm Alarm Enter Choice Previous Screen 0 H elp Figure 11 Status Screen Page 19 For models with UTP ports the Control Screen is available to enable or disable Port A and Port B To select the Control Screen enter C Module Screen iConverter 1 Module Redundant Identifier Chassis Number 7 Slot Number 2 Model Number 8248 512 Port Access Control Setup 1 Port A Enable 2 Port B Enable Port VLAN Path Setup Port to Backplane Port to Backplane Port to Backplane Port to Backplane Port to Port B Enter Choice Previous Screen 0 H elp Figure 12 Control Screen Page 20 5 0 APPLICATIONS 5 1 Battery Backup with Alarms When the chassis is used with a battery backup power system the alarm contact sensor can be used to report conditions associated with the backup power system In this configuration the chassis can provide a managed power fault detection system The figure below depicts an APC PowerShield battery backup unit connected to the chassis using the 8 pin terminal connector on the back of the chassis In this configuration the chassis is monitoring the power conditions of the APC units and will report any failures to the network management system ELL EEE DC Power 1 Module Redu
11. hassis Remote configuration of the chassis is provided by installing an iConverter Management Module such as a 10 100M To configure attach the Management Module to a RS 232 equipped computer with terminal emulation software such as HyperTerminal The Management Module Serial Console Port DCE is a mini DIN 6 female connector which can be changed to a DB 9 connector with the adapter included with the module Part 8082 0 Attach the ends of serial cable to the serial port of the PC and the Serial Console Port of the Management Module This is a standard asynchronous serial interface Start HyperTerminal and select the correct COM Port in the HyperTerminal Connect To window Set the PC s serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE Page 15 Power the chassis containing the Management Module and press lt ENTER gt to bring up a command line prompt on the attached PC The Management Options screen will be displayed Management Options iConverter Serial Agent Network Management 1 Chassis and Module Management 2 Set Module Identifier Management Module Preferences IP and Control Preferences SNMP Preferences Abandon Preference Changes Save Preference Changes Restore to Factory Defaults Restart Management Module Other Networking Features Management Module Maintenance 10 Firmware Update 11 Set Date Time IP Address 192 168 1 220 Cha
12. m the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM Or you may register your product on the Internet at http www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or
13. n High Voltage Terminal The DC power source should be available within 5 ft of the chassis The over current protection for the connection with centralized DC shall be provided in the building installation and shall be a UL listed breaker rated at 20 Amps and installed per the National Electrical Code ANSI NFPA 70 The 8247 3xx and the 8248 3xx require 24 60 VDC 0 6 Amps power The appropriate overloading protection should be provided on all DC power source outlets utilized WARNING Only a DC power source that complies with safety extra low voltage SELV requirements can be connected to the DC input power WARNING REGARDING EARTHING GROUND This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor To power the chassis using a 48 VDC power source
14. ndant Chassis APC PowerShield I Alarm indicators Figure 13 Redundant Chassis Power Utilizing the Contact Closure Sensors Page 21 The four sensors are compatible with APC PowerShield product The table below defines the pinouts for both units iConverter Chassis Description Closed Circuit Open Circuit Utility Power Battery Power Battery Reserve Battery Full Charged Battery Fails Self Test spe Battery Condition Battery Present Battery Missing Low Battery Battery Near Capacity Battery lt 20 Capacity Table 6 APC PowerShield Alarm Contact Configuration 5 2 Contact Closure Sensor Configuration The contact closures can be used to alert the network management system of problems associated with the remote location The contact closure sensor can also detect the opening and closing of a switch such as a equipment door being opened or closed The figure below illustrates this application Open Door Alarm Condition Figure 14 Chassis Configured for Open Door Alarm Page 22 6 0 SPECIFICATIONS iConverter 1 Module Redundant Power Chassis 10Base T 100Base Tx with 1536 max frame size Cable Types P EIA TIA 568A 568B UTI Connector Types Ue 9 24 VDC 1 5A 9 0VDC Low Voltage DC Power 2 5mm Barrel Connector or Field wireable 16 20 AWG Terminal Connector High Voltage DC Power 24 to 60 VDC or 24 to 60 VDC 0 3A 48VDC Field wireable 16 20 AWG Terminal Connector 44 to 57 VDC or 44 to 57
15. s The following table summarizes the UTP pinouts for each of the three PoE Standards supported by this product Standard Source Pin 7 Voltage IEEE 802 af 48 VDC RX RX TX TX using data protected DC DC DC Spare Spare DC Spare Spare pairs A IEEE 802 af 48 VDC using SCH protected pairs B Pre Stand 48 VDC Table 2 UTP PoE Connections UTP Port B does not support the PoE feature Page 10 3 2 LED Indicators The following table details the LED status indicators else corer toaena ar J Sg se Solid Power applied to power source 1 No power applied to power source 1 0 5 Hz Blinking Power applied to source 1 and contact closure is in the alarm state On UTP A linked at 10 Mbps or 100 Mbps Port A Link Activity Lnk Act No link on Port A 49 Hz Blinking Rx and Tx 10 or 100 Mbps data activity on Port A lf Port A link is 10 100 active the port is On UTP Port linked at 100 Mbps linked at 10 Mbps PWR1 Solid Power applied to power source 2 Supply 2 PWR2 dee to 0 5 Hz Blinking Power applied to source 2 P and contact closure is in the alarm state On UTP B linked at 10 Mbps or 100 Mbps Link Activity Lnk Act No link on PotB 40 Hz Blinking Rx and Tx 10 or 100 Mbps data activity on Port B H Port B link is 10 100 active the port is On UTP Port B linked at 100 Mbps linked at 10 Mbps Table 3 LED Definitions Page 11 3 3 Contact Closure Sensors On models with
16. sis to prevent the unit from sliding Make sure the unit is placed in a safe dry and secure location For external power installation and configuration see section 3 0 Page 4 2 2 Module Installation The iConverter 1 Module Redundant chassis supports a variety of managed and unmanaged iConverter modules When installing a module into the chassis carefully slide the module into the open slot Align the module with the installation guides and ensure that the module is firmly seated against the backplane Secure the module by fastening the front panel thumbscrew push in and turn clockwise to tighten to the chassis front Figure 1 Module Installation Note iConverter plug in modules are hot swappable and can be installed into any chassis in the iConverter family For additional information regarding iConverter module installation please consult the specific module s user manual 2 3 Fiber Installation Connect an appropriate multimode or single mode fiber cable to the fiber port of the installed module It is important to make sure that the transmit TX is attach to the receive side of the device at the other end and the receive RX is attach to the transmit side Single fiber SF media converter models operate in pairs The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end For additional information regarding iConverter module fiber installation
17. ssis Number 1 Enter Choice H elp Figure 7 Management Option Screen A new Management Module does not have a password and will skip the Password Entry screen and go straight to the Management Options screen Page 16 If a password has been set the Password Entry screen will be displayed Type the password and press lt ENTERs gt the Management Options screen will be displayed Omnitron Systems Technology Inc iConverter Serial Agent Copyright 2001 2007 OST Inc Password Entry Omnitron Systems Technology Technical Support 949 250 6510 140 Technology 500 Sales Products 800 675 8410 Irvine CA 92618 On the web at www omnitron systems com IP Address 192 168 1220 MAC 00 00 00 00 00 00 XXXXXXXX Pleas nter the password gt Figure 8 Password Screen To access the chassis configuration screens select 1 at the Management Options screen press lt ENTER gt The Chassis View screen will be displayed From the Chassis View screen select the slot number corresponding to the chassis NOTE Chassis configuration is also available using NetOutlook Chassis View 1 Module Redundant Chassis Number 7 Slot Model Type Module Identifier 1 8959 0 2FXM 2 8248 512 1 Module Redundant Module to View 1 2 Mgmt Opt 0 R eset H elp Figure 9 Chassis View Screen Page 17 The Module Screen DIP switch control shown provides general information concerning the configuration and st
18. the contact closure sensor feature see Table 1 the chassis provides an optional 8 pin connector 4 contact sensors on the back of the chassis that can be used to sense the state of external alarm conditions Each of the four sensor pins can detect if the wired circuit is open or closed or has high or low voltage from the external equipment A DIP switch located on the back of the chassis enables or disables alarm reporting If no external equipment is connected to the 8 pin connector it is important to disable the alarm reporting by configuring each DIP switch to the DISABLE position See Figure 5 for the location of the switch and terminal connector Enable saan 1234 Disable Rt Rt Rt Rt Alarms P LI h L Figure 5 DIP switch and Alarm Terminal Details Page 12 The table describes the function of each switch DIP Switch e N Position an Reporting Indication Down Disabled No alarm reporting Alarm 1 Up Enabled Front panel alarm indication Down Disabled No alarm reporting Alarm 2 Up Enabled Front panel alarm indication Down Disabled No alarm reporting Alarm 4 Up Enabled Front panel alarm indication Table 4 Contact Sensors DIP switch Configuration Up Enabled Front panel alarm indication Down Disabled No alarm reporting 3 Alarm 3 NOTE Not all chassis are equipped with the contact sensors Internally all signal return Rt pins are connected The 8 pin connector has th
19. the details concerning the operation and definition of the front panel LEDs Page 6 3 1 2 24 VDC Option Low Voltage Terminal The 8247 x2x 8247 2xx 8248 x2x and the 8248 2xx chassis require 9 24 VDC 1 5 Amps power input The appropriate overload protection should be provided at the power source To power the chassis using 24 VDC power source locate the 24 VDC circuit breaker and switch the circuit breaker to the off position Prepare the power cable using a two conductor insulated wire with a 14 AWG gauge not supplied Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cable to the chassis by fastening the stripped ends to the 24 VDC power connector Repeat the process if the chassis was ordered with the additional low voltage terminal option Warning Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Note The 9 24VDC power input can accept an input voltage up to 28VDC Connect the power wires to the circuit breaker and switch the circuit breaker ON Confirm that the unit has powered up properly by checking the power status LED located on the front of the installed chassis See Section 3 2 for the details concerning the operation and definition of the front panel LEDs Figure 3 Redundant 24 VDC Configuration Page 7 3 1 3 48 VDC Optio
Download Pdf Manuals
Related Search
Related Contents
User Manual - Stand Mixer Reviews 要求水準書 U-Line 2175BEVOL2 User's Manual merlin 6000 slave power supply Zubehör - HOPE 取扱説明書 - 日立の家電品 使用上のご注意 お使いになる前に 主な仕様 Copyright © All rights reserved.
Failed to retrieve file