Home

Allied Telesis AT-CM301

image

Contents

1. DIP Switch 4 DIP Switch 1 Off On 1447 Operating Mode Switch 4 Switch 3 Switch 2 Switch 1 Link Test default setting Off Off Off Off MissingLink Off Off Off On Smart MissingLink Off Off On Off Link Test with OAM Off On Off Off MissingLink with OAM Off On Off On Smart MissingLink with OAM Off On On Off Installing the Media Converter Note The media converter supports hot swapping and can be installed while the chassis is powered on To install the media converter 1 Remove the slot cover from one of the slots in the Converteon chassis by loosening the captive screw with a Phillips head screwdriver The unit can be installed in any of the media converter slots Note Retain the slot cover and reinstall it if you ever remove the card An open slot allows dust to enter the unit and reduces proper airflow in the chassis 2 Align the edges of the line card with the guides in the slot and carefully slide the card into the chassis until it is flush with the front of the chassis Light pressure may be needed to seat the module on the connector on the backplane in the chassis 3 Secure the line card in the chassis by tightening the captive screw with a Phillips head screwdriver 4 Remove the dust cover from the fiber optic port Connect the fiber optic cable to the fiber optic port 6 Connect a twisted pair cable to the
2. F to 158 F Operating Relative Humidity 5 to 90 RH non condensing Storage Relative Humidity 5 to 95 RH non condensing Operating Altitude Range Up to 3 048 m 10 000 ft MTBF 1 500 000 hours Electrical Ratings Power Consumption 8 5 Watts maximum LEDs ECO Friendly Button OAM The recessed ECO Friendly button on the front panel of the line card is used to toggle the Operating Mode SML ML Operations low power mode which controls the LEDs You can use the mode to turn off the LEDs to Smart Missing Link Administration conserve power when you are not monitoring them To toggle the LEDs on or off press MissingLink _ and the recessed button with a pointed object such as the end of a straightened paperclip Maintenance You can also toggle the low power mode with the AT CV5M02 Management Card The 7 low power mode does not affect the network operations of the line card or control the Link Test mode off off off RDY LED Link Test mode with OAM off off On e Default Settings MissingLink mode off On off The default settings for the media converters are listed here MissingLink mode with OAM Off On On Feature Default Setting Smart MissingLink mode On Off Off 3 Basic Settings Smart MissingLink mode with OAM O Off O ei wee OE k Operating Mode Link Test The 100Base FX port has two LEDs Maximum Frare Siz
3. MV Allied Telesis AT CM301 and AT CM302 Fast Ethernet Media Converters Installation Guide Overview The AT CM301 and AT CM302 Media Converters are members of the Converteon family of media converter products They provide a simple and reliable way to connect Fast Ethernet networks across distances of up to 2 kilometers 1 24 miles using multimode fiber optic cable The products feature a 10 100Base TX port and a 100Base FX port The two cards support all of the same features but they have different connectors on the 100Base FX fiber optic ports The features are listed here 10 100Base TX Twisted Pair Port IEEE 802 3u Auto Negotiation Half or full duplex mode Auto MDI MDI X RJ 45 connector O IEEE 802 3x flow control at 10 or 100 Mbps oonu 100Base FX Port Supports distances up to 2 kilometers 1 24 miles using 50 125 um or 62 5 125 um core cladding multimode fiber optic cable Fiber Optic Port Connectors AT CM301 duplex ST AT CM302 duplex SC Operating Modes O Link Test O MissingLink O Smart MissingLink The operating modes can be activated with or without support for Operations Administration and Maintenance Q Operations Administration and Maintenance OAM Features Loopback tests Remote Converteon line card management Remote management software downloads Dying gasp Variable requests Other Features Jumbo frames up to 10 240 bytes Ingress and egress pack
4. RJ 45 twisted pair port on the line card Output Optical Power 62 BOL 19 dBm min 14 dBm max 125 um EOL 20 dBm min 14 dBm max Receiver Wavelength 1310 nm Sensitivity 31 dBm max Maximum Input Power 14 dBm min LEDs LED Color Description The RDY LED displays general status information FD Off The port is operating in half duplex mode Full LED State Status Operating Mode duplex Green The port is operating in full duplex mode RDY Off The line card is initializing the AT S102 Management Software 100M Off The port is operating at 10 Mbps Ready which takes approximately one minute or the card is not receiving power Green The port is operating at 100 Mbps Green The line card has initialized its management software and is ready to transfer network traffic Note The operating mode of the line card is displayed by the SML ML and OAM LEDs For more information on the Link LEDs refer to the explanation of the media converter operating modes in the Converteon AT S73 AT S99 and AT S102 Management Software User s Guide Technical Specifications Physical and Environmental 22 mm x 73 mm x 130 mm 86 in x 2 9 in x 5 1 in Dimensions H x W x L Weight 113 grams 0 25 Ib Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 25 C to 70 C 13
5. e 10240 bytes Twisted Pair Port Auto Negotiation with auto MDI MDI X LED Color Description Ingress and Egress Filtering None LK Off The fiber optic port has not formed a link with the remote device Low Power Mode Disabled Link Green The port has formed a link with the fiber optic port on the remote Operating Mode DIP Switches Enabled device OAM Settings Blinking The media converter is operating in the Smart MissingLink mode Green and the twisted pair port has not formed a link with a network device Admin State Enabled AT Off The port is not connected to a fiber optic cable has not formed a link Mode Passive Activity with the remote device or is not sending or receiving network traffic Maximum OAMPDU Size 1518 bytes Blinking The fiber optic port is receiving or transmitting network packets Green Loopback Support Enabled Variable Retrieval Support Enabled The 10 100Base TX twisted pair port has four LEDs LED Color Description LK Off The port has not formed a link with a network device Link Green The port has formed a link with a network device Flashing Green The media converter is operating in the Smart MissingLink mode and the fiber optic port has not formed a link with a network device AT Off The port is not receiving or transmitting network packets Activity Blinking Green The port is receiving or transmitting network packets Fiber Optic Port Specifications Gen
6. eil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Emission FCC Class A EN55022 Class A VCCI Class A C TICK CE Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN55024 UL60950 1 ULys EN60950 1 TUV CAN CSA C22 2 No 60950 1 Immunity Electrical Safety Copyright 2008 Allied Telesis Inc All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesis Inc www alliedtelesis com
7. eral Maximum Distance 2 km 1 24 miles Fiber Optic Cable 50 125 um or 62 5 125 um core cladding multimode fiber optic cable Transmitter Wavelength Output Optical Power 50 125 um 1310 nm BOL 22 5 dBm min 14 dBm max EOL 23 5 dBm min 14 dBm max Electrical Safety and Emissions Statements Standards This product meets the following standards when installed in compliant host equipment U S Federal Communications Commission RADIATED ENERGY Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved of by the manufacturer or the FCC can void your right to operate this equipment Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appar
8. et rate limiting Operating mode and port status LEDs Low power mode Cyclical redundancy check Suitable for managed and unmanaged network environments Management available with the AT CV5M02 Management Card O AT S102 Management Software preinstalled o agagnondanaa AaAaada Requires the AT CV5M02 Management Card Requires an AT CV5M02 Management Card in the upstream AT CV5000 Chassis Note These line cards cannot be managed with the AT CV5M01 Management Card 613 001068 Rev A Converteon Enclosures This product is supported in all four Converteon enclosures AT CV5000 Chassis AT CV1203 Chassis AT CV1200 Chassis AT CV1000 Chassis Related Documents For background information on the Converteon product refer to the Converteon AT S73 AT S99 and AT S102 Management Software User s Guide available from the Allied Telesis web site Verifying the Package Contents The following items should be in the shipping container O One AT CM301 or AT CM302 Media Converter O This Installation Guide Warranty card If any item is missing or damaged contact your Allied Telesis sales representative for assistance You should retain the original shipping material in case you need to return the unit to Allied Telesis Caution AN The media converter line card is sensitive to and can be damaged by electrostatic discharge Wear a grounding device and observe electrostatic disc
9. harge precautions when installing the card in the chassis Reviewing Safety Precautions Before installing the media converter review the safety precautions detailed in the Converteon chassis Installation Guide Twisted Pair Cable Specifications The cable specifications for the 10 100Base TX twisted pair port are listed here Speed Cable Type Maximum Operating Distance 10 Mbps Standard TIA EIA 568 B compliant Category 3 or 100 m 328 ft better shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz 100 Mbps Standard TIA EIA 568 A compliant Category 5 or 100 m 328 ft TIA EIA 568 B compliant Enhanced Category 5 Cat 5e shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz Fiber Optic Cable Specifications Line Card Connector Maximum Fiber Optic Cable Distance AT CM301 Duplex ST 2 km 1 24 mi 50 125 um or 62 5 125 um core cladding multimode fiber optic cable AT CM302 Duplex SC 2 km 1 24 mi 50 125 um or 62 5 125 um core cladding multimode fiber optic cable Setting the DIP Switches The line card has DIP switches for setting the operating mode You can also set the operating mode with the optional AT CV5M02 Management Card To use the DIP switches refer to the figure and table For background information on the operating modes refer to the Converteon AT S73 AT S99 and AT S102 Management Software User s Guide