Home

Tripp Lite Audio/Video Digital UPS

image

Contents

1. Not suitable for mobile applications important Safety Instructions gt K e eT gt ee orovreosrio Espanol 7 Fran ais 12 TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com Copyright 2007 Tripp Lite All rights reserved All trademarks are the property of their respective owners Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings The UPS is designed for indoor use only in a controlled environment away from excess moisture tempera ture extremes conductive contaminants dust or direct sunlight e Leave adequate space around all sides of the UPS for proper ventilation e Do not mount unit with its front or rear panel facing down at any angle Mounting in this manner will seriously inhibit the unit s internal cooling eventually causing product damage not covered under warranty UPS Connection Warnings e Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection Do not use extension cords to connect the UPS to an AC outlet Yo
2. Surge Only Protected Outlets Provide surge and line noise protection not battery backup Plug equipment that does not require battery backup during a utility power failure such as a printer scanner or fax machine into these outlets Battery Backup Protected Surge Protected Outlets Provide both battery backup and surge protection Plug your computer monitor and other critical equipment into these outlets NOTE DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS USB Communication Port This port can connect your UPS to a computer in order to automatically save open files and shut down the computer if it is left unattended during an extended power failure Use with Tripp Lite s PowerAlert Software and appropriate USB cable A PowerAlert CD and or USB cable are included with select models If PowerAlert is included with your model insert the CD into the CD tray of your computer and follow the installation instructions If PowerAlert Software and or the appropriate cable did not come with your UPS you can obtain the software FREE via the Web at www tripplite com Any user supplied USB cable may be used to connect your UPS to your computer Note This connection is option al The UPS will work properly without this connection Also Note This UPS System automatically provides basic communication com patibility with many integrated Windows Macintosh and Linux power management applications Tel DSL Protection Jacks select models only RJ
3. protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC rules Operation is subject to the following 2 conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Equipment Attachment Limitations models with the Industry Canada label in Canada only
4. 00 SAV LEAD or 1 800 8 BATTERY 1 800 822 8837 or visit www rbrce com for recycling information Tripp Lite offers a complete line of replacement bat teries at www tripplite com Do not attempt to add external batteries to the UPS Quick Installation STEP 1 Place the UPS in either a horizontal desktop or vertical tower position The UPS s housing is designed with sides that slope slightly in order to tilt the LCD Display up for easy viewing in either position horizontal or vertical As another aid to easy viewing the LCD Display can be rotated To rotate the display carefully insert a small tool in the slots on the sides of the display to pop it out of the UPS housing rotate the display and snap it back into the UPS housing CAUTION To safely balance the UPS when it is placed in a vertical tower position make sure the LCD Display is located at the top of the front panel STEP 2 Plug the UPS into an outlet that doesn t share a circuit with a heavy electrical load An air conditioner refrigerator etc After plugging the UPS into a wall outlet push the ON OFF button for one second to turn the UPS on see Basic Operation section Please Note The UPS will not turn on automatically in the presence of live utility power Quick Installation Continued STEP 3 Plug your equipment into the UPS Select outlets will provide battery backup and surge pro tection plug your computer monitor and other c
5. 8 Notice United States Only If your Modem Fax Protection causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment s Modem Fax Protection please call Tripp Lite Technical Support at 773 869 1234 for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Modem Fax Protection This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation commission for information FCC Radio TV Interference Notice U S only Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable
6. NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Regulatory Compliance Identific
7. ation Numbers Note on Labeling For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with Two symbols are used on the label all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number V AC Voltage of the product V DC Voltage follows a policy of continuous improvement Product specifications are subject to change without TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 200703079 93 2663_ES
8. d the alarm is no longer sounding Note The alarm beeps once per minute CAUTION Any overload that is not corrected by the user immediately following a self test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout If the REPLACE icon remains lit and the alarm continues to sound after the test the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 24 hours and repeat the self test If the icon continues to illuminate after repeated self tests contact Tripp Lite for service Battery replacement should only be performed by qualified service personnel If the UPS requires battery replacement Tripp Lite offers a complete line of replacement batteries at www tripplite com Note The alarm beeps once per minute Basic Operation Front Pane Continued LCD Status Screen The LCD Status Screen indicates a variety of UPS operational conditions All descriptions apply when the UPS is plugged into an AC outlet and turned on Note The LCD will illuminate for 1 second when the UPS is plugged in before it is turned on The LCD Status Screen can be rotated for easy viewing regard less of whether the UPS is in a horizontal or vertical a position To rotate the LCD Status Screen insert a small tool in the slots on the sides of the screen to pop it out of the UPS housing rotate the screen and snap it back into the UPS housing 3a Input Voltage Me
9. e problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and pur chase date and will attempt to correct the problem over the phone 3 If the problem requires service the technician will issue you a Returned Material Authorization RMA number which is required for serv ice If you require packaging the technician can arrange to send you proper packaging Securely pack the UPS to avoid damage during shipping Do not use Styrofoam beads for packaging Any damages direct indirect special incidental or consequential to the UPS incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the UPS System is within the 2 year warranty period enclose a copy of your sales receipt Return the UPS for service using an insured carrier to the address given to you by the Tripp Lite service technician Warranty R Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Part 6
10. ed Allow the UPS to recharge continuously for 24 hours and repeat the self test If the icon continues to illuminate contact Tripp Lite for service Battery replacement should only be performed by qualified service personnel 3e ON BAT On Battery Icon During a severe brownout or blackout this icon illuminates and an alarm sounds 4 short beeps followed by a pause to indicate the UPS is operating from its internal batteries Monitor the Battery Capacity Meter to determine the approximate battery charge level available to support equipment During a prolonged brownout or blackout the alarm will sound continuously and the BATTERY CAPACITY Meter will show one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power you should save files and shut down your equip ment immediately 3f FAULT Icon This icon will illuminate and an alarm will sound after a self test to indicate the battery supported outlets are overloaded To clear the overload unplug some of your equipment from the battery supported outlets and run the self test until the icon is no longer illuminated and the alarm is no longer sounding CAUTION Any overload that is not corrected by the user immediately following a self test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout 3g LCD Dimmer Adjusts the brightness of the LCD Status Screen Basic Operation Rear Panel
11. ess and hold the ON OFF Button for one second The UPS will be turned completely off deactivated 1 The alarm will beep once briefly after one second has passed Runtime will be proportionate to the ON OFF Button UPS battery s level of charge EA MUTE TEST Button e To Silence or Mute UPS Alarms briefly press and release the MUTE TEST button Note continuous alarms warning you to shut down connected equipment immediately cannot be silenced eTo Run a Self Test with your UPS plugged in and turned on press and hold the MUTE TEST button for two seconds Continue holding the button until the alarm beeps several times and the UPS performs a self test See Results of a Self Test below Note you can leave connected equipment on during a self test MUTE TEST Button CAUTION Do not unplug your UPS to test its battery This will remove safe electrical grounding and may introduce a damaging surge into your network connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and charge All LCD Display icons will be illuminated and the UPS alarm will sound If the FAULT icon remains lit and the alarm continues to sound after the test the battery supported outlets are overloaded To clear the overload unplug some of your equipment from the battery supported outlets and repeat the self test until the FAULT icon is no longer lit an
12. replace ment should be performed only by qualified service personnel During battery replacement qualified service personnel should refer to Battery Warnings in the Safety section and should observe the following procedure turn the UPS off unplug the power cord and remove the two screws on the UPS back panel to access the internal battery Tripp Lite offers a complete line of replacement batteries at www tripplite com Surge Only Protected Outlets Battery Backup Surge Protected Outlets USB Port Tel DSL Jacks Coaxial Jacks Storage amp Service Storage To avoid battery drain all connected equipment should be turned off and disconnected from the UPS Press and hold the ON OFF button for one second Your UPS will be completely turned off deactivat ed and will be ready for storage If you plan on storing your UPS for an extended period fully recharge the UPS batteries every three months Plug the UPS into a live AC outlet turn it on by pressing and hold ing the ON OFF button for one second and allow the batteries to recharge for 24 hours If you leave your UPS batteries discharged for a long period of time they will suffer a permanent loss of capacity Service Before returning your UPS for service follow these steps 1 Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions 2 If th
13. ritical devices here Select outlets will provide surge protection only plug your printer and other nonessential devices here See Basic Operation Section Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment you connect to the Battery Backup Protected Surge Protected outlets exceeds the UPS s Output Capacity To find your equipments VA ratings look on their nameplates If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA If you are unsure if you have overloaded the Battery Backup Protected Surge Protected outlets run a self test see MUTE TEST Button description CAUTION The UPS must be plugged into a live AC outlet and turned on for 24 hours after initial installation to fully charge the UPS s internal battery Your connected equipment will receive utili ty supplied AC power if present immediately after the UPS is plugged in and turned on howev er your connected equipment may not receive full battery backup in the event of a blackout or severe brownout until the UPS s internal battery is fully charged Basic Operation Front Panel ONOFF Button eTo turn the UPS on Press and hold the ON OFF Button for one second If utility power is absent pressing the Button will cold start the UPS i e turn it on and supply power from its battery eTo turn the UPS off Pr
14. style jacks pro tect connected equipment by stopping surges on a single phone fax or modem line Connect a phone cord from the wall jack directly to the Tel DSL jack labeled IN Connect a phone cord from the Tel DSL jack labeled OUT directly to the device to be protected The UPS system must always be the first item connected in line from the wall jack The UPS system must be plugged into a 3 wire grounded AC outlet for Tel DSL line surge protection to work Connecting your equipment to these jacks is optional Your UPS will work properly without this connection Coaxial Protection Jacks select models only Gold plated coaxial F connectors protect connected equipment by stopping surges on a single DSS satellite cable or antenna line Connect a coaxial cable from the wall jack directly to the coaxial jack labeled IN Connect a coaxial cable from the coaxial jack labeled OUT directly to the device to be protect ed The UPS system must always be the first item connected in line from the coaxial wall jack The UPS system must be plugged into a 3 wire grounded AC outlet for coaxial line surge protection to work Make sure cables connected to satellite dishes antennas etc are also grounded Connecting your equipment to these jacks is optional Your UPS will work properly without this connection Battery Replacement not shown Under normal conditions the original battery in your UPS will last several years Battery
15. ter This meter measures in real time the AC voltage that the UPS system is receiving from the utility wall outlet Although the LCD Status Screen Meter may occasionally display input voltages which stray outside the range of standard computer tolerance due to poor quality utility service rest assured that the UPS is designed through the use of automat ic voltage regulation to continuously supply connected equipment with stable computer grade output voltage In the event of a blackout power loss severe brownout low power or overvoltage high power the UPS will rely on its internal battery to supply computer grade output voltage 3b BATTERY CAPACITY Meter This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout or severe brownout the UPS will switch to battery power the ON BAT icon will be illuminated and the charge level will deplete 2g NEUT VOL VOLTAGE V BATTERY CAPACITY AH AG AVR REPLACE ON BAT FAULT 3c AVR Automatic Voltage Regulation Icon This icon will illuminate whenever your UPS is automatically correcting AC line voltage without depleting battery power This is a normal automatic operation of your UPS and no action is required on your part 3d REPLACE Battery Recharge Replace Icon This icon will illuminate and an alarm will sound after a self test to indicate the UPS battery needs to be recharged or replac
16. ur warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet e If the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might damage the UPS and will void the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Batteries can present a risk of electrical shock and burns from high short circuit current Observe prop er precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service personnel using the same number and type of batteries sealed Lead Acid The batteries are recyclable Refer to your local codes for dis posal requirements or in the USA only call 1 8