1. The 16 port Switch LEDs provide useful information about the switch and the status of all individual ports Green Link Act Yellow 10M G 100M Yellow FDX Col Oae gv LED STATUS CONDITION Display The LED function of Port 1 16 is Link Act Mode Yellow The LED function of Port 1 16 is FDX Col Full Duplex Collision LEDs of if in Link Port has established a valid link Port 1 16 Act function Flashing Data packets being received or sent if in FDX The connection is Full Duplex Col function Flashing Packet collisions occurring A low level of collision is a part of normal Ethernet Operation Green The connection speed is 100Mbps The connection speed is 10Mbps The Display Mode is switched by the PUSH a push button switch on the panel 5 Troubleshooting 5 1 Resolving No Link Conditions The possible causes for a no link LED status are as follow e The attached device is not powered on e The cable may not be the correct type or is faulty e The installed building premise cable is faulty e The switch port may be faulty Note Because Port 16 MDI X port and the MDI port share the same components if the Port 16 MDI X port is used please don t use the MDI port Or if the MDI port is used please don t use the Port 16 MDI X port 5 2 Q amp A 1 Computer A can connect to Computer B but cannot connect to Computer C through the 16 port Switch v The network device of Comput
2. Not Used White Brown 8 NotUsed Brown 8 NotUsed Cable Type and Use Connection Speed Cable Type Hub to Hub or Switch 10Mbps Cross over Cat 3 4 5 twisted pair Hub to Hub or Switch 100Mbps Cross over Cat 5 twisted pair Hub to Server or Workstation 10Mbps Straight Through Cat 3 4 5 twisted pair Hub to Server or Workstation 100Mbps Straight Through Cat 5 twisted pair Hub to Print Server 10Mbps Straight Through Cat 3 4 5 twisted pair Hub to Print Server 100Mbps Straight Through Cat 5 twisted pair C Compliances EMI Certification FCC Class A Certification USA Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures are required to correct the interference Canada Department of Communications Class A This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equ
3. T 100BASE TX RJ45 ports MDI X MDI Selection Alternate Port Dimensions 430 x 105 x 44 mm 16 9 x 4 1 x 1 7 inch Weight 1 4 Kg 3 081b Certification CE Mark Emissions FCC Class A VCCI Class I CISPR Class A Immunity IEC 1000 4 2 3 4 Power Consumption 10Watts max Input Power Full range 100 to 240V 50 to 60 Hz Temperature Standard Operating 0 to 40 C 32 to 104 F Storage 40 to 70 C 40 to 158 F Humidity 5 to 95 Non condensing Network Bridging Function Filtering forwarding and learning Switching Method Store and forward Address Table 8K entries Queue Buffer 512K Bytes Shared Buffer Filtering Forwarding Rate Line speed B Cable Specification Two different types of cable are specified for use on the 16 port Switch e Standard straight through cable e Hub to Hub cross over cable Cable Schematics Standard Straight Through Cable an Switch side eh side H Adapter side Ping Pair TE i O p a Greon_ e o o e OE B me White Orange e e White Orange 4 NotUsed__ Bue 4 NotUsed_ Blue E__NotUsed__ _White Blue_ wewx 5__Not Used White Biue 6 Orange ee TK Orange 7 Not Used White Brown 7 Not Used _ __White Brown E Not Used Brom_ 8 Not Used Brown Hub to JE Cross Over Cable wae rr side i A A side e e RA Whit 4 NotUsed Bue _ 4 Not Used 5 Not Used White Blue 5 Not Used White Blue ee ee 7 Not Used White Brown 7
4. ASET FS Cat 3 4 5 Twisted pair cable Max 100m 328 et 3 2 Connecting to Another Ethernet Switch Hub The Switch can be connected to existing 10 Mbps or 100 Mbps hubs switches The switch to switch hub connection guidelines are as follows 3 2 1 MDI to MDX Connect Use normal Straight Through TP Cable when connecting the Switch MDI port to another standard port at the other FROM MDI port Straight Through cable Max 100m 328Pt TO MDX port switch hub 3 2 2 MDX to MDX Connect Use crossover TP cable when connecting the Switch device port to another standard port at the other switch hub FROM MDX port Cross over cable Max 100m 328 ft TO MDX port 3 3 Application An Ethernet switch can be used to overcome the hub to hub connectivity limitations as well as improve overall network performance Switches make intelligent decisions about where to send network traffic based on the destination address of the packet As a result the switch can significantly reduce unnecessary traffic The example below demonstrates the switch ability to segment the network The number of nodes on each segment is reduced thereby minimizing network contention collisions and boosting the available bandwidth per port Switch Another Ethernet we Ba l Speed Hub lt Nr lt Me za we Power User p wi i ra Nar Lad Fe lt Workgroup Workgroup 4 LEDs Conditions Defined 4 1 LEDs Defined
5. KS 116 16 Port 10 100 Workgroup Switch Installation Guide We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability quality or fitness for any particular purpose The information in this document is subject to change without notice We reserve the right to make revisions to this publication without obligation to notify any person or entity of any such changes Trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies Installation Guide 16 Port 10 100Mbps Workgroup Switch Sixteen 10 100Mbps RJ45 TX ports w one MDI uplink port shared with Port 16 reo eee F Front View Indicator Panel MDI X Ports MDI Port GA A a E Rear View Power Switch Power Socket Power 100 240VAC 1A P N 17000067 Contents Installation Guide 1 Introduction 1 1 Package Contents 1 2 Installation Procedure Where to Place the Switch 2 1 Placing the Switch onto a Desk or Shelf 2 2 Mounting the Switch onto a Rack Configure The Network Connection 3 1 Connecting Devices to the Switch 3 2 Connecting to Another Ethernet Switch Hub 3 2 1 MDI to MDX Connect 3 2 2 MDX to MDX Connect 3 3 Application LED Conditions Defined 4 1 LEDs Defined Troubleshooting 5 1 Resolving no Link Conditions 5 2 Q amp A Appendix A Product Specifications Appendix B Cable Specifications Appendix C Electro magnetic an
6. d Safety Compliances Appendix D Warranty 1 Introduction This 16 port Switch is a plug and play 10 100Mbps Fast Ethernet switching hub This switch can auto sense the operation speed 10Mbps or 100Mbps and operation mode full or half duplex It is very easy to install and use Every network connection can use up to 200Mbps bandwidth to transfer data because of the switch architecture of the Switch The total bandwidth of the Switch is 1 6Gbps Users can use this 16 port Switch to enhance their network performance easily There is a clear indicator panel for Link Act Full duplex Collision and connection speed of each port for network status monitor 1 1 Package Contents One 16 port 10 100Mbps Ethernet Switch One AC power cord Two rack mount kits and screws This installation guide 1 2 Installation Procedure Install the Switch Section 2 Connecting Devices to the Switch Section 3 Diagnosis the Network Connections Troubleshooting Section 4 5 Section 4 2 Where To Place the Switch This 16 port Switch can be placed on a flat surface your desk shelf or table or mounted onto a rack Place the 16 port Switch at a location with these connection considerations in mind e The switch configuration does not break the rules as specified in Section 3 e The switch is accessible and cables can be connected easily to it e The cables connected to the switch are away from sources of electrical interferenc
7. e such as radio computer monitor and light fixtures e There is sufficient space surrounding the hub to allow for proper ventilation the switch may not function according to specifications beyond the temperature range of 0 to 40 degrees C 2 1 Placing The Switch on a Desk or Shelf 1 Place the first switch on a firm flat surface where you want to install the stack 2 Place next switch on the first switch Please don t put more than three this 16 port Switches in a stack to prevent shaking of the stack 2 2 Mounting The Switch Onto a Rack 1 Use the brackets and screws supplied in the rack mounting kit 2 Use a cross head screwdriver to attach the brackets to the side of the switch 3 Position the switch in the rack by lining up the holes in the brackets with the appropriate holes on the rack and then use the supplied screws to mount the switch onto the standard EJA 19 inch rack 3 Configure the Network Connection 3 1 Connecting Devices to the Switch Connection Guidelines e Use Category 3 or 5 twisted pair Ethernet cable when connecting 10BaseT devices to the switch cable pin assignments defined in Appendix A e Use Category 5 straight through twisted pair Ethernet cable when connecting 100BaseTX devices to the switch cable specifications are defined in Appendix B e Always limit the cable distance to 100 meters 328 ft as defined by IEEE specification Cat 5 Twisted pair cable Max 100m 328 et 40B
8. er C may fail to work Please check the link act status of Computer C on the LED indicator Try another network device on this connection v The network configuration of Computer C may be something wrong Please verify the network configuration on Computer C 2 The possible causes for the 16 port Switch no work status are as follow v Power cord or the internal power supply problem Check the Power LED indicator y MDI MDI X port is misused Never use MDI port and Port 16 MDI X port at the same time because they share the same components v The cable may not be the correct type or is faulty And the cable length limit is 100 meters v The installed building premise cable is faulty 3 The LED display does not work correct v Because the LED of Port 1 16 can be switched between Link Act or FDX Col functions please check if the LED display is in the correct display mode Please refer to Section 4 for LED Display A Product Specifications Access Method CSMA CD 10 Mbps or 100 Mbps Standards Conformance IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX Communication Rate 10 100 Mbps on RJ 45 ports Communication Mode Full Half duplex Media Supported IOBASE T 100 Ohm Category 3 4 5 twisted pair 100BASE TX 100 Ohm Category 5 twisted pair Indicator Panel LEDs for Power Display Mode Link Act Speed or FDX Col Speed One PUSH button on the front panel for Display Mode switch Number of Ports Sixteen 10BASE
9. ipment standard entitled Digital Apparatus ICES 003 of the Department of Communications VCCI Class I Compliance Japan CORES ARRIERE S SRRSSEMalmmRe VOCI DEE ITED OS RAPER TI CORE TRER TRAT ote AEE REITI aY ET DOES 3A S OCHRE BT SLIBRANSCEMHVET CE Mark Declaration of Conformance for EMI and Safety EEC This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 class A EN60555 2 1995 class A EN60555 3 IEC1000 4 2 1995 4kV CD 8kV AD IEC1000 4 3 1995 3V m IEC1000 4 4 1995 1kV power line 0 5kV signal line This product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Warning Do not plug a phone jack connector in the RJ 45 port This may damage this device D Warranty We warrant to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of warranty time from the date of purchase from us or the authorized reseller The warranty does not cover the product if it is damaged in the process of being installed We recommend that you have the company from whom you purchased this product install it