Home
Tripp Lite Internet Office UPS System
Contents
1. BC Pro Fe NOM Tested To Comply With FCC Standards FOR HOME OR OFFICE USE Not suitable for mobile applications f important Safety instructions O K easi operation Storage amp service O EEO 7 Espa ol 8 Fran ais 16 S C a TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2006 Tripp Lite All rights reserved BC Pro is a registered trademark of Tripp Lite Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of this product Failure to heed these warnings will void the warranty UPS Location Warnings Install the UPS indoors away from excess moisture or heat dust or direct sunlight For best performance keep the indoor temperature between between 32 F and 104 F 0 C and 40 C Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings Connect the UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS plug and do not use an adapter that would eliminate the ground connection Do not use extension cords to connect the UPS to an AC outlet The warranty will be void if anything other than Tripp Lite surge suppressors are used to con
2. Network Line B USB Communications Surge Suppression The UPS has jacks which protect against surges over a phone or network data line Using telephone cords as appropriate connect the wall jack to the UPS jack marked IN Connect equipment to the UPS jack marked OUT Make sure the equipment connected to the UPS jacks is also protected against surges on the AC line Use any USB cable to connect the computer s USB port to the USB port of the UPS Download the PowerAlert UPS monitoring software program appropriate for the computer s operating system from www tripplite com software and install it Basic Operation Buttons ON OFF Button C Switch the Operating Mode While the UPS is plugged into a live AC outlet press the ON OFF button and hold it until the UPS beeps about 2 seconds to toggle between ON and OFF s ON Mode ENABLES battery backup UPS Conditions The UPS charges the battery and supplies power to the outlets while receiving utility line power The v indicator light will illuminate If utility power fails the UPS provides power from battery Cold Start Cold start the UPS to use it as a stand alone power source when utility power is not present if the UPS battery is charged To cold start the UPS press and hold the ON OFF button until the UPS beeps about 2 seconds then releas
3. ATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the warranty period enclose a copy of the sales receipt Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC RADIO TV INTERFERENCE NOTICE Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from t
4. e it The indicator will illuminate and AC power inverted from stored battery power will be provided to the outlets Basic Operation continued MUTE TEST Button Silence the UPS On Battery Alarm Press and hold this button to silence the UPS on battery alarm a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery Note When the battery is nearly depleted the low battery alarm a continuous beep that cannot be silenced will warn to shut down connected equipment immediately Run a Self Test To run a self test leave connected equipment on With the UPS plugged in and ON press and hold the button until the UPS beeps about 2 seconds then release it Self Test Results All LEDs will be lit and the UPS will emit several short beeps as it momentarily switches to battery to test charge and load capacity The test will last up to 10 seconds If the inverter is overloaded the audible alarm will sound and the UPS will automatically shut down if this happens remove some of the load from the UPS Surge outlets and run the self test again If the batteries are weak the 2 LED will stay lit and the UPS will continue to beep after the test If this happens let the UPS charge its batteries for 12 hours and repeat the test If the condition persists contact Tripp Lite for service CAUTION Do not unplug the UPS to test its batteries This will remove safe
5. eb at www tripplite com support battery index cfm to locate the specific replacement battery for your UPS Do not attempt to add external batteries Quick Installation H Connect the UPS to an electrical outlet Make sure the outlet does not share a circuit a with a heavy electrical load such as an air conditioner or refrigerator E B Plug a computer monitor and or other equipment into the UPS system The UPS is designed to support only computer equipment Connecting high power draw equipment such as household appliances or laser printers to outlets providing UPS battery backup will overload the UPS Special outlets clearly labeled on the rear panel provide surge only not battery backup protection designed for laser printers and other high power draw equipment UPS Surge receptacles are used to provide connected equipment with AC line power during normal operation and battery power during blackouts and brownouts They also protect equipment against damaging surges and line noise Connect the computer and monitor to the UPS Surge receptacles Ei Select UPS Operating Mode Press the ON OFF button to toggle the UPS between the ON v LED lit and the OFF V LED not lit modes Quick Installation optional These connections are optional The UPS will function properly without these connections H Phone Line
6. electrical grounding and may introduce a damaging surge into network connections Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on LINE POWER This green light will illuminate whenever the UPS is ON and receiving normal AC line power BATTERY POWER This yellow light will illuminate when the UPS is providing equipment with battery power REPLACE BATTERY This red light will illuminate continuously after the UPS runs a self test to indicate that the battery is weak If it remains lit after allowing the UPS to charge for twelve hours and running a second self test contact Tripp Lite for service Basic Operation continued Other UPS Features NORM DELAY AC Receptacles UPS Surge receptacles are used to provide connected equipment with AC line power during normal operation and battery power during blackouts and brownouts They also protect equipment against damaging surges and line noise Surge Only receptacles are used to provide peripherals with surge protection without committing precious battery power to support them during blackouts Telephone DSL Ethernet Protection Jacks These jacks protect equipment against surges over a telephone or data line Connecting equipment to these jacks is optional The UPS will work properly without this connection USB Communication Port Th
7. experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform and switches to battery less often NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion the UPS will allow to pass to connected equipment When experimenting with different settings for this dial operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations The experiment should last long enough to assure that all expected line conditions are encountered Storage amp Service Storage All connected equipment should be turned off then disconnected from the UPS to avoid battery drain Unplug the UPS from its AC receptacle then press and hold its ON OFF button to deactivate it The UPS is now ready for storage When storing the UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 12 hours If the UPS batteries are discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning the UPS for service contact the local Tripp Lite dealer or distributor They will provide a referral to a service center Please carefully pack the UPS using the ORIGINAL PACKING M
8. hat which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Part 68 Notice United States Only If your Modem Fax Protection causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment s Modem Fax Protection please call Tripp Lite Technical Support at 773 869 1234 for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Modem Fax Protection This equipment may not be used on coin service provided by the telephone company Connection to party l
9. in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite has a policy of continuous improvement Product specifications are subject to change without notice Note on Labeling Two symbols are used on the label V AC Voltage DC Voltage TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 200609130 93 2621_EN
10. ines is subject to state tariffs Contact your state public utility commission or corporation commission for information EQUIPMENT ATTACHMENT LIMITATIONS Models with the Industry Canada label in Canada only NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important
11. is port can connect the UPS to any computer for automatic file saves and unattended shutdown in the event of a power failure Use with Tripp Lite s PowerAlert Software and USB cable A USB cable is included with the UPS PowerAlert Software is available FREE via the Web at www tripplite com software NOTE This connection is optional The UPS will work properly without this connection Battery Replacement Door Under normal conditions the original battery in the UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section Should the UPS require battery replacement visit Tripp Lite on the Web at www tripplite com support battery index cfm to locate the specific replacement battery for the UPS Power Sensitivity Adjustment This dial is normally set fully counterclockwise which enables the UPS to protect against waveform distortions in its AC input When such distortions occur the UPS will normally switch to providing PWM sinewave power from its battery reserves for as long as the distortions are present In some areas with poor utility power or where the UPS s input power comes from a backup generator frequent brownouts and or chronic waveform distortion could cause the UPS to switch to battery too often draining its battery reserves It may be possible to reduce how often the UPS switches to battery due to waveform distortion or brownouts by
12. nect the UPS to an outlet e If the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of the UPS This may damage the UPS and will void the surge suppressor and UPS warranties Battery Warnings The UPS does not require routine maintenance Do not open the UPS for any reason There are no user serviceable parts inside e Batteries can present a risk of electrical shock and burns from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Use tools with insulated handles Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or in the USA only call 1 800 SAV LEAD or 1 800 8 BATTERY 1 800 822 8837 or visit www rbre com for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the W
Download Pdf Manuals