Home

Intel AXXBASRAIL13 mounting kit

image

Contents

1. The inner slides must be positioned all the way forward in the rails to ensure proper installation of the server 2 Engage the matching rails and slide the server chassis into the rack see letter B in Figure 5 until the two safety stops lock into position see letter C in Figure 5 AF000631 Figure 5 Installing the Server Chassis into the Rack 6 Basic Rail Kit Install Guide for Intel Server Chassis Rail Kit Installation Instructions 3 Depress the two safety locks one on each side See letter A in Figure 6 4 Slide the server chassis all the way into the rack See letter B in Figure 6 5 Use the rack screws 778 32 x 3 4 to secure the chassis and rack handles into the rack See letter C in Figure 6 AF000630 Figure 6 Installing the Server Chassis into the Rack Basic Rail Kit Install Guide for Intel Server Chassis 7 Rail Kit Installation Instructions 8 Basic Rail Kit Install Guide for Intel Server Chassis
2. at http support intel com support motherboards server sb cs 010770 htm Wichtige Sicherheitshinweise Lesen Sie zun chst s mtliche Warnund Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Sicherheitshinweise zu Intel Serverplatinen und Servergeh usen auf der Intel Server Deployment Toolkit CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le ntel Server Deployment Toolkit CD ou bien rendez vous sur le site http support intel com support motherboards server sb cs 010770 htm Instrucciones de seguridad importantes N Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar cualquiera de las instrucciones Vea Intel Server Boards and Server Chassis Safety Information en el Intel Server Deployment Toolkit CD y o en http support intel com support motherboards server sb cs 010770 htm EITHER A Z BU BMAP ARRAREN FHS http support intel com support motherboards server sb CS 010770 htm EA Intel Server Boards and Server Chassis Safety Information Intel IRSOEBERSMRSBVAZE fig Basic Rail Kit Install Guide for Intel Server Chassis i
3. death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2008 Intel Corporation All Rights Reserved ii Basic Rail Kit Install Guide for Intel Server Chassis Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions See also Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit CD and or
4. inner rail from the rail assembly See letter C in Figure 2 AF000627 Figure 2 Removing the Inner Rail from the Rail Assembly Basic Rail Kit Install Guide for Intel Server Chassis 3 Rail Kit Installation Instructions Install Outer Rail Slides to Rack Posts 1 Attach the outer rail slides to the rack posts using two 48 32 x 1 2 screws at the front posts and two 28 32 x 1 2 screws at the rear posts See letter A in Figure 3 Note The rail flanges mount to the inside of each post AF000628 Figure 3 Installing the Outer Rail Slides to the Rack Posts Basic Rail Kit Install Guide for Intel Server Chassis Rail Kit Installation Instructions Attach Inner Rails to Server Chassis Sidewalls 1 Insert the inner rails over the server chassis sidewall studs See letter A in Figure 4 2 Slide the inner rails toward the front of the server chassis See letter B in Figure 4 3 Secure the inner rails with one 6 32 x 1 4 screw for each rail See letter C in Figure 4 AF000629 Figure 4 Attaching the Inner Rails to the Server Chassis Sidewalls Basic Rail Kit Install Guide for Intel Server Chassis Rail Kit Installation Instructions Install the Server Chassis into the Rack 1 Align the inner rails attached to the server chassis with the outer rail assemblies attached to the rack See letter A in Figure 5 Note
5. 6 Installing the Server Chassis into the Rack 7 Basic Rail Kit Install Guide for Intel Server Chassis vii List of Figures viii Basic Rail Kit Install Guide for Intel Server Chassis 1 Rail Kit Installation Instructions Use the instructions in this installation guide to install the AXXBASRAIL13 rail kit to one of the following Intel products Intel Server Chassis SR1500 Intel Server Chassis SR1550 Intel Server Chassis SR1600 Intel Server Chassis SR1625 Intel Server Chassis SR2400 Intel Server Chassis SR2500 Intel Server Chassis SR2600 Intel Server Chassis SR2625 Intel Server System SR1560SF Before You Begin Before installing the rail kit observe these safety guidelines 1 Turn off all peripheral devices connected to the server 2 Turn off the server by pressing the power button on the front of the chassis Then unplug the AC power cord s from the chassis or wall outlet 3 Label and disconnect all peripheral cables and all telecommunications lines connected to I O connectors or ports on the back of the chassis 4 Provide electrostatic discharge ESD protection by wearing an anti static wrist strap attached to a chassis ground any unpainted metal surface when handling components Tools and Supplies Needed Phillips cross head screwdriver 1 bit and 2 bit Anti static wrist strap and conductive foam pad recommended Basic Rail Kit Install Guide for Intel S
6. Basic Rail Kit Install Guide for Intel amp Server Chassis A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Server Chassis SR1500 Intel Server Chassis SR1550 Intel Server Chassis SR1600 Intel Server Chassis SR1625 Intel Server Chassis SR2400 Intel Server Chassis SR2500 Intel Server Chassis SR2600 Intel Server Chassis SR2625 Intel Server System SR1560SF Intel Order Number D59599 003 Rev 02 Disclaimer Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or
7. able provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and handling boards Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a jumper or you may bend or break the pins on the board iv Basic Rail Kit Install Guide for Intel Server Chassis Contents Contents Safety Information E iii Important Safety Instructions eism t iii Wichtige Sicherheitshinweise AEN iii Mrapiisp Es N be
8. erver Chassis 1 Rail Kit Installation Instructions Kit Content List AXXBASRAIL13 Each Rack Mount Kit contains the following Note The two included rail assemblies are NOT interchangeable Each is installed into the rack by its orientation right or left when standing in front of the rack The right rail assembly is identified with a BLUE RH sticker and the left rail assembly is identified with a GREEN LH sticker Note This kit includes two sets of 8 32x 1 2 screws One set of eight has a larger screw head size than the second set of eight Use the set of 8 32x1 2 screws that best fits the rack in which the rail kit is being installed Outer Rail Slide Assembly 2 See letter A in Figure 1 Inner Rail Slide 2 See letter B in Figure 1 Rail Safety Stop one each on inner slides See letter C in Figure 1 Outer Slide Rail Screws 8 48 32 x 1 2 See letter D in Figure 1 Inner Slide Rail Screw 8 46 32 x 1 4 See letter D in Figure 1 e Rack Screws 2 28 32 x 3 4 See letter D in Figure 1 AF000626 Figure 1 Rail Kit Components 2 Basic Rail Kit Install Guide for Intel Server Chassis Rail Kit Installation Instructions Installation Instructions Remove the Inner Rail from the Rail Assembly 1 Extend the inner rail until it locks See letter A in Figure 2 2 Depress the spring safety lock to release the inner rail See letter B in Figure 2 3 Remove the
9. ii Safely Information Warnings Heed safety instructions Before working with your server product whether you are using this guide or any other resource as a reference pay close attention to the safety instructions You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold System power on off The power button DOES NOT turn off the system AC power To remove power from system you must unplug the AC power cord from the wall outlet Make sure the AC power cord is unplugged before you open the chassis add or remove any components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not avail
10. iii Instrucciones de seguridad importantes ssssseeeseeen menn iii Rail Kit Installation Instructions eeeeeeee eee ee Lceeeeeeeeeeee eene 1 Before You BegiN 1 Tools and Supplies Needed sess seen enne nennen nnn enn nnn tenerent rennen nene 1 Kit Content List AXXBASRAJIL139 2 ierra cena senatui denar re ek nau dr nad Ra AR 2 Installation Instructions ssssssse mme nennen nnne nnne nnne 3 Remove the Inner Rail from the Rail Assembly AAA 3 Install Outer Rail Slides to Rack Posts sssessessssessseeseeeeeenee nnne eene nnn 4 Attach Inner Rails to Server Chassis Sidewalls eesssseeeeeennnnns 5 Install the Server Chassis into the Rack ssssssssssssesseeeeeeneee enne eene nnne 6 Basic Rail Kit Install Guide for Intel Server Chassis V Contents vi Basic Rail Kit Install Guide for Intel Server Chassis List of Figures List of Figures Figure 1 Rail Kit Components ecsici necs nent rtkhn tana nn ink una a nR tk ne cra Fu SR CER RR REN Rapids 2 Figure 2 Removing the Inner Rail from the Rail Assemblv A 3 Figure 3 Installing the Outer Rail Slides to the Rack Poet 4 Figure 4 Attaching the Inner Rails to the Server Chassis Sidewalls 5 Figure 5 Installing the Server Chassis into the Rack 6 Figure

Download Pdf Manuals

image

Related Search

Related Contents

PowerTraveller PMEV2001 mobile device charger  Modo de empleo Mantenimiento ¿Qué hacer?  OPENCOCKPITS IOCard USBRELAYS MANUAL DE INSTALACION  FICHA DATOS TÉCNICOS AR C.C. 30%  Cahier n° 4 : Accompagner une PME dans son  CDA WF250SS User's Manual    SXS500M2: Back Up Alarm  Spin and Learn Top Manual  NuTiny-SDK-NUC123 User Manual  

Copyright © All rights reserved.
Failed to retrieve file