Home
Honeywell SP5600 Optimus R
Contents
1. r Field data IV Fix data length v Initial value or text V Add prefix code Add suffix code J Show input mark Left Aligned Padded with S r Barcode Input Y Read Partial Barcode IAE MOD 10 Add Double Add next high cT MOD 10 Triple Add Triple next high MOD 11 Repeat Arithmetic next high MOD 10 Double 4dd Double next low Maximum length MOD 10 Add Double Add next low v Check leading code MOD 10 pie Add Triple next low Scan Enter Fixed data length HEntettS Can cc Figure 8 Properties Options Click on the checkbox to activate this option This setting sets the allowable length of the data collected to a fixed length The developer determines that length by the number entered in the field Any data entered into this field that is greater than the specified value will be truncated For data entered that is less than the specified value spaces or 0 s will be added in front of or end of the transaction data depending on the Left or Right alignment The alignment is determined by the drop down menu see Figure 8 If the checkbox is unchecked the data length of this field is unstructured The Form data field will instead be bound by the data type and minimum length and maximum length specified for this input field Initial value or text This setting specifies whether or not there will be an initial value or text for this field
2. 13 Application Creation Properties Cont Add prefix code Setting adds a set string as a prefix to data entered in this field Click on the checkbox to activate selection Add suffix code Setting adds a set string as a suffix to data entered in this field Click on the checkbox to activate selection Show input mark Show input marks for example the underline character in this field indicating the maximum length of the data required for the field Read partial bar code By default the system will return the whole bar code that has been decoded Activating this setting enables the systems ability to use part of the bar code that is specified by the settings The starting position of each bar code defaults to 1 and the maximum length defaults to 20 Check leading code The leading code check is used for verifying the bar code input If the leading code is not matched the input bar code will be rejected Check Digit Verification Check digit verification is a special check on a numeric or an alphanumeric field in which the last rightmost character is a check digit Verification can be either modulus 10 or modulus 11 Modulus checks are used when the risk of error keying in numbers must be reduced to a minimum The Optimizer has both available via the drop down menu under the Check Digit Verification setting Auto ENTER The auto ENTER setting automatically appends the data entered with a carriage return The developer c
3. Output Record The Output Record setting will not save the data The data will be sent directly to the host device Output Screen The Output Screen setting will not save the data This option will configure the Optimus to output the entire contents of terminal s screen prompts and data 11 Application Creation Record selection options cont Save and Output Record This selection option allows the developer to configure the Form to accomplish two tasks instantly It allows the transactional data to be saved in a table on the unit and outputs data directly to the host device Save and Output Screen The Save and Output Screen setting will save the transactional data in a table on the unit and output the entire contents of terminal s screen prompts and data Date and Time Stamp The date and time stamp can be customized as well The date and time stamp can be added to the front or end of the transactional data collected The format of the time stamp can also be customized to fit the desires of the customer See figure 6 x r Date Format Y MM DD 4 p Time Format HH MM SS IV Yea 4 Digits vvv y V Hour v Month v Minute Y Day V Second JV Separator V Separator Date Style Year Month Day z IV Separate DATE stamp and TIME stamp to two fields DK Cancel Figure 6 Date and Time Stamp settings Lookup Table The lookup table property gives the devel
4. 95947 ROISSY CDG CEDEX Tel 33 0 1 48 63 78 78 Fax 33 0 1 48 63 24 94 Email info fr metrologic com Italy Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell Emilia BO Tel 39 0 51 6511978 Fax 39 0 51 6521337 Email info it metrologic com Poland Metrologic Instruments Poland Sp z 0 0 Poleczki 21 02 822 Warsaw Poland Tel 48 22 545 04 30 Fax 48 22 545 04 31 Email info pl metrologic com 38 Singapore Metrologic Asia Pte Ltd 50 Kallang Avenue 01 02 Noel Corporate Building Singapore 339505 Tel 65 6842 7155 Fax 65 6842 7166 Email info sg metrologic com China MTLG Auto ID Instruments Shanghai Co Ltd Room 1419 No 1 Ji long Road Waigaoqiao Bonded Zone Shanghai 200000 Tel 86 21 58692780 Fax 86 21 58692782 Email info cn metrologic com China Suzhou Sales Office BLK A Room 03 03 04 No 5 Xinghan Street Xinsu Industrial Square China Singapore Suzhou Industrial Park Suzhou PRC Tel 86 512 67622550 Fax 86 512 67622560 Email info cn metrologic com China Guangzhou Sales Office Room 2307 Foreign Economic and Trade Building 351 Tianhe Road Guangzhou City Guangdong Province PRC Tel 86 20 38823476 Fax 86 20 38823477 Email info cn metrologic com Contact Information and Office Locations South America and Central America European Middle East and Brazil Metrologic do Brasil Ltda Rua da Paz 2059 CEP 04713
5. Goto This setting allows the developer to specify a particular form or menu that the menu item will transition too 17 Application Creation Menu properties cont Save Data Click on the checkbox to activate this setting If this setting is activated it will configure the Optimus to save the data for each form in a separate file Menu and Item caption Save caption Add the menu caption to the transaction record if this menu is running Save selected item Save the selected menu item to the data file if this menu is used Pass down Do not save the above data just pass it to the next menu or form Action ESC The setting specifies which form or menu to be shown when the user hits the ESC key Normally this key is used to go back to the previous form or menu Menu Caption The Menu caption setting specifies the caption for the current menu This is an optional setting 18 Application Creation LOOKUP TABLE A lookup table is a database file created for information reference The lookup table provides data to the active form when there is a match to a field in the table The level of interaction is dependent on the settings of the active form The Optimizer program allows the developer to create up to three lookup tables A lookup table includes the following properties 1 Lookup Table Number 2 Field Property 3 Number of fields 4 Field number 5 Offset 6 Length 7 Primary Key 8 Action
6. Setting determines if the data can be uploaded to the host device from the terminal 20 Application Creation BAR CODE The bar code property page includes all the bar code types that are supported by the Optimus The developer can enable or disable each type of bar code In addition the developer can configure the parameters of each bar code type to conform to the application requirements The many settings under each bar code symbology enable the developer to create application programs that will enhance all transactional data gathered by the Optimus The Bar code properties include 1 Time out 2 Read Redundancy 3 Code Types untitled Optimus S Optimizer File Language Tools Help Dc Application Template 11 Startup ls _ S secends 1 Settings amp Initia Read redundancy None Once C Twice C Three times Menu 13 Lookup Table Code Types cdi 0 Form I2of5 E pai Industrial 25 Interleave 25 1235 Codabar Code EAN MSI LG Matrix 25 Negative 39 93 128 ss Codabar Negative cS Code 29 9328 ER ER EN ER EAN wp MSI laliar French Plessey Telep RSS UPCE LPCA 4 harmacods en llalian French Pharmacode Plessey T elepen ASS UPCE UPCA Metrologic Figure 11 Time out The Time out setting determines the maximum amount of time the Optimus will engage the integrated laser scanner This time out duration is specified in units of seconds The default time out
7. gt arn This is the location the transactional data received will be stored The setting can 7 Add Retum character teach record Peo Append Overwrite v Add Line Feed character to each record be setup by clicking on the text box and typing in the directory location where the data will be stored It is also possible to ducunt use the browse button to select a location for the data Y View the received data v Always show this dialog box v Keep online for receiving data automatically Polling time 2 1 999 sec cor Figure 30 Receive Data Options 35 Communication Receive Data properties cont File Mode This setting is the mode by which the data will be written to the file Overwrite Allows the developer to specify the file name Creates a new file and if there is an already existing file by the same name it overwrites it with the new data Append Allows the developer to specify the file name Creates a new file if there is already an existing file by the same name it will add the new data to the end of the file Output to Keyboard Acts like a keyboard wedge unit Data is outputted like a keyboard one character at a time Auto Similar to overwrite but allows the data read utility to run in the background polling the COM port waiting for a terminal to upload Creates a random filename based on the time 24hr Auto Append Similar to Auto but allows the developer to s
8. Qualification Because of the weak structure of the 2 of 5 codes a partial scan has a high probability of decoding as a valid but shorter 2 of 5 codes known as short scan To prevent this kind of undesired reading the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length Code length parameters can be configured in two ways Fixed Code Length or Max Min code length If the fixed code length is selected up to 2 fixed lengths can be specified And if max min code length is selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified Read Odd Number of Digits This parameter is available only for the Interleave 25 This parameter must be enabled in order to read Interleave 25 labels that contain odd number of digits Codabar CodaBar is a variable length bar code type that permits the encoding of the following 22 characters 0 1 2 3 4 5 6 7 8 9 comma A B C D The characters A B C and D are only used as start and stop characters Thus the first and last digits of a CodaBar message must be A B C or D and the body of the message should not contain these characters Enable Codabar Enables Codabar as an active bar code type Codabar Negative Start Stop Selection There are four different start stop pairs v Enable Codabar available as listed below
9. duration is three seconds 21 Application Creation Bar code properties cont Read Redundancy Read redundancy is a method by which the scanner can reliably determine that the data gathered is accurate by conducting multiple scans of the information The default setting is none If the read redundancy setting is set to once the scanner will decode the bar code one additional time and if the decoded information of both scans is identical than the data collected is determined to be good data reduce the scan rate of the Optimus The bar code decoding scanning It is important to note that increasing the level of read redundancy will 1 ability of the scanner will be prolonged to verify the data being scanned Code Type These settings establish all of the bar code types that are active for the application program Only the active bar code types will be scanned All inactive code types will be disregarded and will not scan Industrial Interleave Matrix 25 Interleaved 2 of 5 is a high density variable length numeric only symbology that encodes digit pairs in an interleaved manner The odd position digits are encoded in the bars and the even position digits are encoded in the spaces Because of this 2 of 5 bar codes must consist of an even number of digits Also because partial scans of 2 of 5 bar codes have a slight chance of being decoded as a valid but shorter bar code readers are usually set to read a fi
10. info uk metrologic com Kingsclere Road Basingstoke Hampshire RG21 6XG Tel 44 0 1256 365900 Fax 44 0 1256 365955 Email info uk metrologic com 39 China Beijing Sales Office Tower A 5th Floor Unit 5204 China Intn l Science and Tech Convention Center No 12 Yu Min Road Chao Yang District Beijing China 100029 Tel Fax 86 10 82253472 Email info cn metrologic com India Metrologic India 403 4th Floor Carlton Towers No 1 Airport Road Bangalore India 560 008 Tel 91 80 51256718 Fax 91 80 51256719 Email info in metrologic com Japan Metrologic Japan Co Ltd Matsunoya Building 6 Floor 3 14 8 Higashiueno Taitou ku Tokyo 110 0015 Japan Tel 81 3 3839 851 1 Fax 81 3 3839 8519 Email info jp metrologic com
11. m Start Stop Character 1 None None 2 abcd abcd C abed abed 3 abcd tn e PU 4 ABCD ABCD rates 5 ABCD TN E C ABCD ABCD C ABCD TN E Enable Negative Figure 13 23 Application Creation Bar code properties cont Code39 The Normal CODE 39 is a variable length bar code type that can encode the following 44 characters 1 2 3 4 5 6 7 8 9 0 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Each Code 39 bar code is framed by a start stop character represented by an asterisk The Asterisk is reserved for this purpose and may not be used in the body of a message In cases where data security is required Code 39 allows for a check character Code 93 CODE 93 is a variable length bar code type that can encode the complete 128 ASCII character set CODE 93 is an enhancement to the Code 39 bar code type that provides a slightly higher character density than Code 39 CODE 93 also incorporates two check digits as an added measure of data security Code128 Code 128 is a variable length high density alohanumeric bar code type Code 128 has 106 different bar and space patterns and each pattern can have one of three different meanings depending on which of three different character sets is employed One character set encodes all upper case and ASCII control characters another encodes all upper and lower case characters and the third set encodes numeric digit pair
12. 002 Ch cara Santo Ant nio Sao Paulo SP Brasil Tel 55 11 5182 8226 Fax 55 11 5182 8315 Email info br metrologic com Outside Brazil Metrologic South America Rua da Paz 2059 CEP 04713 002 Ch cara Santo Ant nio Sao Paulo SP Brasil Tel 55 11 5182 7273 Fax 55 11 5182 7198 Email info 2sa metrologic com European Middle East and African Headquarters Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim Munich Germany Tel 49 89 89019 0 Fax 49 89 89019 200 Email info europe metrologic com Germany Austria and Switzerland Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim Munich Germany Tel 49 89 89019 0 fax 49 89 89019 200 Email info de metrologic com African Headquarters Asian Headquarters Singapore Russia Metrologic Russia Bolshaya Novodmitrovskaya 14 RU 125015 Moscow Russia Tel 7 095 730 7424 Fax 7 095 730 7425 Email info ru metrologic com Spain Metrologic Eria Ib rica SL Juli n Camarillo 29 D 1 28037 Madrid Tel 34 913 272 400 Fax 34 913 273 829 Email info es metrologic com Metrologic European Repair Center MERC Metrologic Eria Ib rica SL C Alfonso Gomez 38 40 1D 28037 Madrid Tel 34 913 751 249 Fax 34 913 270 437 United Kingdom Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road Basingstoke Hampshire RG21 6XG Tel 44 0 1256 365900 Fax 44 0 1256 365955 Email
13. 19 Field Prop e 19 N mber of fields see ee ROG eei iei END GE 20 dz EXER 20 IJ CD 20 Lengt MC qpvubeanevcens 20 Pnmary Koy ibat t eei bue tu ure e erc bieten iain ner rre istnd e be dr os 20 Action Input HAS TIO match rte coti t eie ingerit n eerte ii 20 Action Formatof record Is WI Ohg ct e reete He A adi RR eee 20 Data read and upload rere eo ene et ere nis EE Norte ree e eg ERE Ee Pere e ree do sa 20 lf ze 21 TIG OU o hs ob eot aM A Mi Mu o des LR Ne loo M cM A er M dedos dd ee les 21 Head Bed ndancy bene do 22 Code Type eene D Reo e dabas 22 Es sanior de rRNA eat ated a E a tl e E e Ld AE dada 22 Codabari o e escena Mee UE ea e ek ale oes oh MEL Por AM Euer D ed LE Ct ep IE AS 23 Geox M Em Em 24 COSI S ER 24 Code 128 Enn 24 EANS E EAN Tr e tee a de e e e I S 25 MS e bra ld nd ed IN ea dl Pe 26 Table of Contents Italian French Pharma OOA A essent tnnt teneerne entree eter entree erret tese stesse tese er esee tes sers seres seres NS 27 PE us aca aca sesh acs erates ote ou coherent KEA EE OE ENNES 28 REI 28 LU rad Steet tact ce hU a DE Mm MA a MEE Ra MEC 28 DURA ep tu En ME MEM E E AARIN AME 29 STATUS aka 30 Application dd Mi A AA eet e iE RAN 31 Prompt amp Message Settings esses eese eene tenete thee nnt tenete then a eren tene entree ne
14. AN13 Addon 5 scanner to scan and decode the 2 character supplemental Figure 15 25 Application Creation Bar code properties cont Enable EAN13 ISBN ISSN Conversion If these settings are enabled the scanner will convert the code read into ISBN or ISSN code if the formats are correct EAN13 codes start with 978 or 979 for ISBN and 977 for ISSN Transmit Checksum If this parameter is enabled the checksum character will be included in the data being transmitted Enable G T I N Global Trade Identification Number This setting enables the scanner to scan and decode the GTIN embedded within the EAN8 and EAN13 bar code types Enable EAN13 Addon Enable EAN13 Addon 2 Setting enables the ability of the scanner to scan and decode the 2 character supplemental Enable EAN13 Addon 5 Setting enables the ability of the scanner to scan and decode the 2 character supplemental MSI MSI is a variable length numeric only bar code type The bar code type is based on a four bit binary number scheme Each character is framed by a start and a stop pattern and contains a check character that is calculated from the values of each of the encoded data digits MSI Checksum Verification Setting specifies that the scanner will perform checksum verification when decoding bar code Three kinds of checksum calculations can be implemented for MSI code Single Modulo 10 Enables the Optimus to scan and decode b
15. Menu Options This option allows the user to download an application program to the Optimus When downloading an application program the Optimizer downloads all active settings in the Application Template of the current window to the Optimus This option allows the user to download a specific lookup table to the Optimus Note see Common Terms for Lookup Table definition This option allows the user to setup the reception of data from a particular Optimus This is used to interface with an existing database for real time lookups and data updates The Help menu provides version number and other information about the Optimizer program This option is not available when the application template selected is either the OptimusS WLAN or the OptimusR WLAN This options is not available when the application template selected is either the OptimusS or OptimusR Application Creation An application is mainly composed of two components Form and Menu These are the two key elements required to create a customized application program In order to create an application program customized for a customer s application it will be necessary for a developer to be familiar with all of the available menus of the Optimizer program In this section the properties of those menu options will have detailed descriptions FORM A Form is the basic building block of an Optimizer Application It is essentially a data collection template with input prompts Da
16. able 34 Communication Download Lookup Table Utilizing this option the developer can download a customized lookup table to the Optimus using the Download Lookup Table option A small window will appear with configuration settings See Figure 29 The configurable settings are similar to the xl Download Program option The one i l difference being the browse button by Filename Browse clicking on the browse button the developer can select the appropriate C Program Files Optimizer Lookup TxT lookup table The lookup table used should be a text file e g Lookup TXT DgmiGes vius MODEM As with the Download Program option if EOE mm the modem option is selected the Baud rate 00bps EGA Configure button will become active and must be clicked on in order to configure the modem and have a proper communication via the modem option cea Note Communication settings must Figure 29 Download Lookup Options match between the OP_Load and Optimus or data cannot be transmitted Receive Data x The Receive Data Read Data utility option is a utility that can be used to transmit data Directory C Program Files Optimizer 0 directly to the host device The com port and Femme Menooge TXT baud rate must still be set properly The l developer is also able to customize certain COM port 2 1 25 format settings 115200 Baud rate 57600 38400 19200 Directory l l File mode Dvemwie
17. active on the Optimus upon power up The Startup menu enables the application program developer to specify which settings and prompts will be accessible upon the initialization of the Optimus unit properties include 1 Startup a Application start from b Number of Delimiter 2 Prompt and Message Settings 3 Prompt amp Message a Use large font for all prompts b Import Prompts amp Messages The Startup menu y default Optimus S Optimizer O xl File Language Tools Help D cu r Startup uem Template Application start from Number of Delimiter Value Char Startup E E Settings For E 1 o Ez ox 1 Bar Code FE amp T Menu 2 Lookup Table Prompts amp Messages Main Menu 2 x 16 M Form Use large tont tor all prompts 1 Run Program Run Program Import PromplssiMessages 2 Utilities pue Prompt Items Main Menu 1 Run Program Save Record Eno Messages 2 Ullities 7 1 Transfer Files 1 Get Program 2 Send Data 2 Browse Records 3 Clea Records Delete Record 4 Reader Tes zi Reset All Metrologic Figure 21 Startup Property Options 30 Application Creation Statup Application start from This setting determines the form or menu that will be active initially on the Optimus The active form or menu is determined by the number of forms and menus available for the particular application program e g If two menus are creat
18. an determine the location of the carriage return via the drop down box and have the return after the data is entered Scan ENTER or added before ENTER Scan the data so the user need not press the ENTER key to move to the next field Lookup No lookup table is selected by default The lookup setting will identify a specific field within the available lookup table to be accessed If the specified lookup field is the Primary key field in a lookup table all other input fields that form will be filled with the lookup data A lookup field prefixed with means any data for that field will be updated to the original lookup data A lookup field prefixed with means any added data for that lookup field will be subtracted from the original lookup data If you configure a lookup table in the lookup table menu it can be assigned to a form Application Creation Min Len and Max Len The Min Len property sets the minimum length the bar code must be in order to qualify as a valid bar code The Max Len property can be set to limit the length of the data for a particular field The properties work in conjunction The Optimizer program automatically limits the values available If the maximum length is longer than the field can display the entered data will left scroll or move to the next field if the data type of the next field is EXTENSION If the length of a bar code is longer than the maximum length the system will prompt a warming message to the
19. ar code that contain the single Modulo 10 checksum 26 Y Enable MSI r Checksum Verfication Single Modulo 10 m Checksum Transmission C Last digit not transmistted C Double Module 10 Transmitted C Modulo 11 amp 10 C Last 2 digit not transmistted Length Gualification 4 Length C Fixed Length Max Length 127 Max Min Length Mix Lenath Figure 16 Application Creation Bar code properties cont Double Modulo 10 Enables the Optimus to scan and decode bar code that contain two Modulo 10 check digits Modulo 11 amp 10 Enables the Optimus to scan and decode bar code that contain the Modulo 10 and 11 check digit Note f the checksum is incorrect the bar code won t be read Checksum Transmission The developer can control how the checksum is transmitted by configuring these parameters 1 Last digit not transmitted 2 Transmitted 3 Last 2 digits not transmitted Length Qualification Because of the weak structure of the MSI code a partial scan has a high probability of decoding as a valid but shorter MSI code To prevent this kind of undesired readings the Code Length settings can help to ensure that the correct code is read by qualifying the allowable code length Code length limitations can be set in 2 ways Fixed Code Length If the fixed code length is selected up to 2 fixed lengths can be specified Max Min code length If max min co
20. button marked Reset All Additionally the developer can choose to use a large font for the prompts and messages specified 31 Import Prompts amp Messages 2 Utilities r Main Menu 2 x 16 1 Run Program 1 Run Program 2 Utilities B 2 Utilities E 1 Transfer Files 1 Get Program 2 Send Data 2 Browse Records 3 Clear Records Delete Record 4 Reader Test zl Reset All Figure 22 Prompts amp Messages Use large font for all prompts Import Prompts amp Messages Prompt Items Main Menu T Run Program Save Record Error Messages 2 Utilities E 1 Transter Files 1 Get Program 2 Send Data 2 Browse Records B 3 Clear Records Delete Record 4 Reader Test xl Reset All Figure 23 Application Creation Settings The Settings property enables the developer to set the communication method for multiple interfaces beep tones data operation methods security with password protection and hot button function keys Under the Settings menu there are the following three options 1 Initial 2 Security 3 Function Key Initial The initial property settings are the basic settings required for initial setup The options under this property will determine the many operational variables In order to alter those operational methods the developer will be required to change the following properties Upload and Download options Data Deletion Record Prompts Beep tones
21. cess by which the Form will follow Next Fom1 y based on the active settings of the Action parameters Esc Main y Next Record The Next setting determines where the application Save ici duds program will proceed automatically upon completion of the current active Form e g loop the same form over and over again or have a multi form process Save into data file Update lookup table Save amp update Pass down Dutput Record Dutput Screen Esc The Esc setting linked to the ESC key on the Optimus keypad This setting provides the developer with the ability to map the ESC key for navigation to another form Figure 5 or to escape to the main menu save amp Output Screen Yi Record The developer has the ability to control how the transactional data being collected is processed using the Record setting This setting contains a drop down menu see Figure 13 that has multiple options available for selection to determine the course of the data Save into data file The default setting It will set the Form to save the data into a separate table in the Optimus unit Update Lookup The data in the lookup table is modified as specified by the Form settings Save and Update Performs both the Save into data file and Update lookup action Pass down The data collected will not be saved within the current form rather it will pass the data to the next form in sequential order
22. constantly search for data from the Optimus Activating this setting will enable the host device to poll the Optimus for data at a specified interval of time The time interval must be set in seconds 1 999 seconds Polling time The amount of time specified for the host device to poll the Opimus for newly acquired data 37 Contact Information and Office Locations Corporate Headquarters Metrologic Instruments Inc 90 Coles Road Blackwood NJ 08012 4683 Tel 856 228 8100 Fax 856 228 6673 Sales Fax 856 228 1879 Marketing Fax 856 228 0653 Legal Finance Email info metrologic com North America Metrologic The Americas 1571 Imperial Way Suite B West Deptford NJ 08066 Tel 1 856 537 6400 Fax 1 856 537 6474 Email info us metrologic com Adaptive Optics Associates AOA Ten Wilson Road Cambridge MA 02138 1128 Tel 617 806 1400 Fax 617 806 1899 Email info aoainc com Omniplanar 1571 Imperial Way Suite A West Deptford NJ Tel 856 537 6100 Fax 856 537 6116 Email info omniplanar com European Middle East and African Headquarters amp Germany Office Asian Headquarters Singapore Eastern Europe and Middle East Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim Munich Germany Tel 49 89 89019 222 Fax 49 89 89019 173 Email info east metrologic com France Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord Il BP 50057
23. de length is selected the max length and the min length must be specified and the scanner will only accept those codes with lengths that fall between the max min length specified in the Length setting Length The min and max length the length qualification setting references to qualify a bar code as a valid bar code Italian French Pharmacode Italian French Pharma code For Italian French Pharmacode there is always a checksum character included in the bar code So the checksum verification is always performed when decoding these bar codes The user though can choose whether the checksum character is to be transmitted or not The start stop transmission of this code shares the same setting of Code 39 Enable Italian Pharmacode Figure 17 Checksum Transmission Setting specifies whether the checksum characters are included in the transmitted data 27 Application Creation Bar code properties cont Plessey A variable length numeric only bar code type Each symbol is framed by a start and a stop pattern and contains a check character that is calculated from the values of each of the encoded data digits Telepen Telepen is the only bar code type to directly represent the full ASCII character set without shift characters It is an extremely secure bar code type that has negligible risk of misreads Enable Plessey Convert to UK Plessey If this parameter is enabled the scanner wvill change each
24. e Metrologic We really work for you METROLOGIC INSTRUMENTS INC Optimizer User s Guide Table of Contents o Mee c NERO RASE 5 U TIEREIES 208353 tsb EEE thee ceo oleh seh as texto had b cba s enu einst ian o toa ca 5 GOMMONCREBMS odas eite daos a n dd thea ewes canines 6 Getting ESI La CETO ere E T sa cp E P sQe rar YOr FER KIM T 7 A EE E E E EE T AA DE aol geo eect ahaa a ge AEE E ETE 8 S cU c E APA cara Sangean at ld A EEEE 8 TIOS a IE M 9 PP MENDES arbi p O o MA d CA M M AU Ud UTI 9 Application Creation is 10 ue ii rada das 10 Form NUMDG Mes a eee dead de a Lo a ESEE e ea LL Le de 11 ACUM o Mc E 11 Date and Time Stamp s dett etre Redi t n eee e t nm e e e ERR edet 12 LOOKUP TAG es 12 SE VAI iss cc tate E N EEE ER 12 aie cs m 13 Min Lenta MELO a usse er tret tree idea dede s 15 INPUETYDO 15 dejo ee A 15 PEICHBRUISTL 15 MENU me S 17 Menu NUDE EE 17 NN 17 Ic 17 Save Data ene NN 18 Menu adn lem Caption e tt ede e RITTER Ue i e ie E e PER VI E Pe EET Ee REUS 18 Yelle eec a o e 18 LOOKUP RA RRA 19 Lookup Table Number tere n tete detec
25. ed and one form then those are the only active options that will be available in the drop down box Number of Delimiter This setting determines if there will be any delimiter for the transactional data scanned There are a maximum of two characters available to act as the delimiter in the startup menu The default setting for this property is one with a comma being the delimiter Prompt and Message Settings This area next to the Prompt and Message property window is where all of the settings for each prompt or message are displayed For each prompt or message highlighted a variety of settings will appear that can be altered to fit the developers application program requirements Prompts amp Messages The settings available under this r Prompts amp Messages Use large font for all prompts Prompt Items Main Menu B 1 Run Program Save Record Error Messages property give the developer the ability to use custom prompts and messages Redefining the prompts and messages can be accomplished by importing an existing Optimizer file into the startup menu The default prompts and their corresponding settings are displayed in the window under the property settings The default prompts and messages have different settings under each that can be edited to conform to any custom application In the event that the developer desires to have the default settings reestablished this can be done by simply clicking on the
26. en function keys with specific actions linked to that particular function key essentially a hot button There are a maximum of seven special functions keys available for custom configuration The function keys can be setup to perform a variety of actions as shown in Figure 26 To enable the function keys activate the check box for Enable Function Key Mappings The drop down box next to each function key provides a list of all the available actions m Security Password 10 digits Metrologic Settings Upload Method Edit Data Download Method I Clear Records Transmin speed Set Data Time Backlight Get Program Data Deletion Get Lookup Record Prompting Figure 25 Security Options untitled Optimus 5 Optimizer BI xj File Language Tools Help Dc Application Template JV Enable Function Key Mappings 1 Startup G Settings Function 1 FN 1 Initial Security Function 2 FN 2 Pun Program Function Key es e ransfer Files Ep Function 3 FN 3 Browse Records H Menu Clear Records 3 T Lookup Table Reader Test ce T Form Function 4 FN 4 Settings Function 5 FN 5 Nil Download Method Transmit Speed Backligh Function 6 FN 6 Nil Function 7 FN 7 Nil r Set Date Time View Settings Figure 26 Function Key Options 33 Communication Communication menu allows the developer to transfer data and programs
27. et setting value identifies the start position for particular field of the lookup table It is important to note that the total value of the Offset and the Length settings can be no greater than 255 Length The Length setting specifies the length of the field in the lookup table It is important to note that the total value of the Offset and the Length settings can be no greater than 255 Primary Key References field in a lookup table to populate all other fields in a record if there is a match Action when the input has no match Setting determines the appropriate action to be taken when the input data does not have a match in the lookup table database The default setting is continue meaning the program will proceed to the next input field without showing any message The following are the available actions to be taken Continue Show warning message Insert to lookup table Show warning message and insert Clear the screen Show warning message and clear screen DIAN Action when the format of the record is wrong Setting determines the appropriate action to be taken when the table is being downloaded to the Optimus if the transactional data format does not match the settings specified in the lookup table The default is stop the download process meaning that the active download with stop The following are the available actions 1 Stop the download process 2 Truncate Reformat the record 3 Skip the record Data read and upload
28. for key clicks good read and warnings Backlight Transmit Speed Download Method DUO UU orm y untitled Optimus S Optimizer m al xj File Language Tools Help Dea E Application Template tial settngs Startup Upload Method Data Deletion g m emm E CradieR C WA Manual C Automatic nial t C Modem C Bhetooth SPP J n Ke BT mode only Record Prompts 11 Bar Code Miedo C No prompt Show count T Menu Lookup Table Download Method Show data E Fo C Cradiel C IDA Stayon the LCD e 99 amp 100m C Modem C Bluetooth SPP C Press any key to continue BT mode only C Tonel Tone2 ALS pr Transit Speed 7 Tone C Torei C Tones z Barcode Good Read Baud Rate 115200 bps C Mute One beep L C Twobeeps C Thee beeps Backlight Disablec C Enabled Tum Backlight off ifidle for gt 179 x10sec Waming teop C One beep Two beeps C Three beeps Figure 24 Initial Settings 32 Application Creation Security The Security settings available give the developer the ability to limit certain functions This is accomplished by setting a password for those functions thereby limiting access to certain functions to a select group of individuals The developer can create a 10 character password that must be entered to change any property that has the selection box checked Function Key The Function Key property allows the developer to setup sev
29. ld Application Creation MENU A Menu is the other key component to a well structured application program The Menu allows the developer to subdivide and configure the access of different forms for numerous applications The association between the menus and forms give the developer the ability to design application programs that make even the most difficult applications manageable The Optimizer can create a maximum of 10 menus each with unique settings See Common terms for menu definition page 5 Below is the description of each of the Menu settings Menu number Item Caption Goto Save Data Menu amp Item Caption Action OCT Oe a s untitled Optimus 5 Optimizer 45 x lt 2 Application Template a BEAT Small 16 chars x 10 lines 1 C Large 12 chats x 10 lines 2 Main 3 Main Me Action 4 Main Esc Man 5 Main Me FT LE Main 8 Me Y Menu caption 7 Main Q e 8 Main 8 Ss 9 Main 8 M L 10 Mai de Menu amp Item ca 5 Lookup Table ption 5 ig Y Save ca ption gt v Save selected it 2 Form ae iem Fom 1 e I Pass down e e Fom o Figure 9 Menu Number The Menu number selection allows the developer to select menu 1 through 10 As a feature the developer can create 10 unique menus and each menu is capable of having unique settings Item caption Setting determines the name of each menu item
30. musR application templates The OptimusS WLAN and OptimusR WLAN application templates have a maximum length of 50 characters 15 Application Creation Data Type properties Cont Text Any ASCII character Integer An Integer is a positive whole number e g 1 2 3 negative whole number 1 2 3 and zero 0 Real Real number is any rational or irrational number This includes whole negative and decimal numbers Letter Alpha characters are letters of the alphabet both lower case and uppercase letters may be used A to Z Auto Automatically increases or decreases the original value of the lookup field by 1 Boolean Accepts only 0 1 Y or N input Lookup The input will come from the specified lookup field in the lookup table Unlike the other data types text integer real and letter the data of the lookup type can not be changed by the user Fixed data Not allowed to input but the data will be added to the transaction data Prompt Not allowed to input and the data in this field won t be saved Counter Not allowed to input but shows the record counts in this field Pass down The data of this field will come from previous form or menu where Record type was specified as pass down Extension Use the same data type as previous line but no prompts can be specified in this field The maximum data length is determined by the maximum data length of the previous fie
31. nte ten 31 Prompts amp Messages e neo vcre me e o D isla dd HE eU eiii A pere ee D ES 31 SETTINGS de serie aerate eave wwtw cance vada caw iaa 32 Initial poa Be ee T odor da da da Rec dete Salk the undi e Aa Bed EEEE nerd Base Joe 32 SEU e 33 FUNCION KEY iaa 33 COMMUN AO SEE TEEOSTTTOS TTD TOTIS OU a a E EE ONE TE a UTEM 34 DOWNLOAD PROGRAM o anne rre nnns 34 DOWNEOADAZOOKUP a ABLE on dad bt tnb A A bb bc i be orbis 35 RECEIVE DAA E os orc UU TENE TENET IERI M IM I UM 35 Contact Information and Office Locations cceeeeeeeeee eene enne nnn nnn 38 Introduction The Optimizer software program is a rapid SW development tool designed and developed specifically for the Optimus series of portable data terminals The Optimizer program is a well structured application program that has user friendly menus and easily accessible options all of which make Optimizer the perfect companion software to produce the most optimal results for both the user and any custom application The Optimizer has a multitude of features that include Ease of Install Graphical User Interface GUI Intuitive menus Variety of comprehensive options The Optimizer s GUI enables the user to define the parameters by which the data collection operation shall function The menus and options allow users to easily create data collection templates and download applications to the Optimus The Optimi
32. occurrence of the character A into character X in the code Transmit Checksum If this parameter is enabled the checksum characters two characters will be transmitted together with data Enable Telepen AIM Telepen Support full ASCII code including all alphanumeric and special characters Original Telepen Support only numeric numbers UPC E UPC E is a small seven digit UPC bar code type for number system O It allows for a supplemental two or five digit number to be appended to the main bar code symbol The supplemental is simply a small additional bar code that is added onto the right side of a standard UPC symbol and consist of either 2 or 5 characters Enable UPC E This setting enables UPCE as an active bar code type Convert to UPC A Converts the UPCE bar code scanned to a UPCA bar code and follows the characteristics associated with the UPCA code type 28 Plessey T elepen r Enable Plessey Convert to UK Plessey v Transmit Checksum CT Enable Telepen f Alf Telepen Full 451 Orignal Telepen Numeric Figure 18 UPCE Iv Enable UPCE Convert to UPCA Transmit System Number J Transmit checksum m UPCE Addon Enable UPCE Addon 2 Enable UPCE Addon 5 Figure 19 Application Creation Bar code properties cont Transmit System Number The UPCE comes with 2 varieties System Number 0 and System Number 1 These two differ in the way data
33. oper the option of setting up a specific lookup table to be accessed for use with the form Branch B ranch Function Key Branch to Branching allows the user to use function keys to automatically FN 1 Disable v leave the current form and go directly to another form or menu N2 ose zi without having to save data To setup the Branching properties simply use the drop down menu and select the form that will m3 se correspond with the particular function selected There are a FN 4 Disable v maximum of four function keys that can be setup to perform this Bess operation Using the Branch setting limits the capability of the available function keys This option is not available when the application template selected is either OptimusS WLAN or OptimusR WLAN Figure 7 12 Application Creation Properties Parsing is used when the developer needs to analyze or separate the data input into more easily processed components The parsing options are illustrated in Figure 8 The parsing options available allow the developer to add a suffix or prefix Additionally Optimizer can setup the data length to be a fixed length and pad the data if necessary The Bar code Input can enable the Optimus to read partial codes verify check digits and setup how the data should be entered Left Aligned Padded with Space Right Aligned Filled with Space Left Aligned Padded with 0 Right Alig
34. orm Menu Lookup Table A collection of similar data separated into different groups to make it easy to organize and find specific items A the structure where all data is stored A database is usually made up of multiple tables A single row of a table A record holds all the information about a particular item A single column in a record A field holds information about a single attribute of a particular item The basic building block of an Optimizer Application The developer lays out fields on the screen and associates variables with the lines the user will fill in Multiple forms can be used to accomplish different tasks Can be used to group structures of forms to accomplish different tasks File can be downloaded to the terminal and stored as a table and then uploaded back to the host to have a complete inventory database Lookup files are not necessary for functionality as data tables can be created for each form independent of the lookup table Getting Started After successful installation of the Optimizer program on the host device activation of the program can easily be accomplished The application window for the Optimizer program will appear on the display of the host device untitled Optimus 5 Optimizer 7 zi x Fie Language Tools Help D oc Dona oa 0 m Bar Code 11 Startup 1 Settings 11 Bar Code ff Menu 11 Lookup Table 13 Form Startup Settings Menu Looku
35. p Table Form E B A Metrologic Figure 1 Optimizer Startup Window Figure 1 illustrates the opening screen of the Optimizer program The opening screen enables the user to view all of the available menu options The first step in developing an application for the Optimus is understanding the functionality of the Optimizer programs many menus and settings Many of the menus and settings are self explanatory Understanding the extensive list of settings offered by the Optimizer program will allow even the novice developer to create detailed application programs In turn those programs will allow the users of the Optimus to complete data collection tasks quickly and easily The list of menu options begins with those available at the top of the screen File Language Tools Help The installation of the Optimizer program should run automatically upon insertion of the CDROM If the installation does not commence upon insertion of the CDROM please see the troubleshooting section of this manual on page XX Getting Started The File menu contains the familiar Windows M options such as New Open and Save However it also contains options unique to the Optimizer program as illustrated in Figure 2 File Language Tools Help New Ctrl Open Ctri O Save Ctri 5 Sd O 0000 G Startup Settings Bar Code Menu Lookup Table Form Terminal Type Convert to Optimus X Exit Me
36. pecify a file to append downloaded data File Name File Name is the name of the file that will be created when the data is received The file will stored in the location specified by the directory setting The file will be saved as text TXT file Add Return character to each record Clicking on the check box will activate this setting This setting will add a carriage return CR to the end furthest to the right of each data entry Add Line Feed character to each record Activating this setting will allow each data entry received to be imported into the file on separate lines It will add the line feed LF character to each data entry Show Messages in case of error This setting is checked will display the error messages should any occur View the received data This setting will prompt the user to decide if all data being received should be viewed To activate the setting the check box must be checked If the setting Keep online for receiving data automatically is active this will not be an available option 36 Communication Receive Data properties cont Always show this dialog box This setting must be activated in order to have the Receive Data options available for configuration It is important to note that if this box is unchecked the configuration settings for the receiving data will not be available to alter Keep online for receiving data automatically This setting will cause the application to
37. s 00 through 99 This third character set effectively doubles the code density when printing numeric data Code 128 also employs a check digit for data security Enable Code 39 Click on this checkbox to enable Code 39 as an active bar code type Transmit Start Stop Code 39 93 128 Setting specifies whether the start stop characters of Code 39 are included in the data being transmitted Transmit Start Stop rj w Enable Code 39 Verify Checksum Verify Checksum Setting specifies is the scanner will perform checksum verification when decoding bar codes Code 39 Full ASCII v Transmit Checksum Note If the checksum is incorrect the bar code won t be read w Enable Code 93 Transmit Checksum Setting specifies whether the checksum characters are included in the data being transmitted Figure 14 v Enable Code 128 Code 39 Full ASCII Enable this setting to read and decode full ASCII Code 39 The default setting enables the scanner to read and decode the standard Code 39 24 Application Creation Bar code properties cont Enable Code 93 Click on this checkbox to enable Code 93 as an active bar code type Enable Code 128 Click on this checkbox to enable Code 128 as an active bar code type EAN8 EAN13 EAN or European Article Numbering system also called JAN in Japan is a European version of UPC It uses the same size requirements and a similar encoding scheme as for UPC codes EAN 8 encode
38. s 8 numeric digits consisting of two country code digits five data digits and one check digit EAN 13 is the European version of UPC A The difference between EAN 13 and UPC A is that EAN 13 encodes a 13th digit into the parity pattern of the left six digits of a UPC A symbol This 13th digit combined with the 12th digit usually represent a country code Both EAN 8 and EAN 13 support a supplemental two or five digit number to be appended to the main bar code symbol Supplemental messages must consist of either two or five numeric digits and will appear as a small additional bar code on the right side of a standard EAN symbol Enable EAN8 Setting enables EAN8 as an active bar code type Convert to EAN13 This setting enabled will allow an EAN8 bar code type read to be expanded and converted to an EAN13 The decoding of the bar code will then be processed as an EAN193 Transmit Checksum The checksum character will be EAN included in the data being Y Enable EANS gt rdv Enable EAN13 transmitted when this setting is i enabled Convert to EAN13 ISBN Conversion v Transmit checksum ISNN Conversion Enable EAN8 Addon EANG Addon Iv Transmit Checksum Setting enables the ability of the scanner to scan and decode the 2 Enable EAN8 Addon 5 EAN13 Addon character supplemental Enable EAN13 Addon 2 Enable EAN8 Addon 5 Enable EANT28 Setting enables the ability of the TS Transmit bode tL F Enable E
39. ta can be saved in a transaction table or updated in a lookup table after the user completes the input of a form The Optimizer is able to develop and use multiple forms to accomplish a multitude of tasks The Optimizer has the capability of creating a maximum of 10 forms Under the Application Template select the Form menu option to access the Form properties 1 Form number 2 Action 3 Date and Time Stamp 4 Lookup Table 5 Branch 6 Parsing 7 Min Len and Max Len 8 Input Type 9 Prompt 10 Data Type untitled Optimus S Optimizer File Language Tools Help DG Branch Function Key Branch to FN 1 Disable kd FN 2 Disable y Font FN 3 Disable M Small 16 chars x 8 ines C Large 12 chars x 4 ines cr Ct FN 4 Disable Y 1 Bar Code M Menu Record Save into datafile Y 2 3 OVDODVODIDO a up Table BB ne eo x 06660000000 Figure 4 Form Properties 10 Application Creation Form Number The Form number selection allows the developer to select form 1 through 10 As a feature the developer can create 10 unique forms and each form can have different settings Having the flexibility of 10 forms enables the developer to create enhanced application programs Action The Action property allows the developer to setup navigation Fom 1 control and data output of a Form It allows the developer to m pred T setup step by step the pro
40. to and from the Optimus to a host device To access the communication settings highlight the Tools menu See Figure 27 Communication option will appear with three options available for setting up communication to the host device untitled Optimus S Optimizer 01 xl File Language Tools Help itr E Communication gt Download Program F6 Download Lookup table F7 Application Template Receive data F8 0 m tj a Startup H E Settings Startup Settings Bar Code Menu Lookup Table Form Bar Code E Menu 3 1 Lookup Table E Form Metrologic Figure 27 Download Program The utility used for program downloads is OP_Load This executable utility enables either the developer or the user to configure the program download for RS232 Cradle IR and Modem It is necessary to specify the correct communications port 1 255 are COM port available for the host device Baud rate is another setting which must be set correctly RS232 or IrDA s0P_Load v1 11 Credle IR MODEM Download via Baud rate If the modem option is selected the Configure button will become active and must be clicked on in order to configure the modem and have proper Figure 28 Program Download communication via the modem option Note Communication settings must match between the OP Load and Optimus or data cannot be transmitted Depending on the model of Optimus selected will determine the options avail
41. trologic Figure 2 File Menu Options The options unique to the Optimizer program are Terminal Type and Convert to Optimus R Terminal Type Allows the user to choose the correct model template This is important when determining the correct settings for the active application Convert to This option gives the developer the ability to create an application program for a particular terminal and convert it to the necessary format of another terminal The Language menu allows the user or developer to choose the active language The default is English Optional language modules can be loaded for custom language requirements For more information contact a Metrologic Instruments representative Getting Started The Tools menu though a familiar listing for Windows M programs has options completely unique to the Optimizer program In Figure 3 the available options under the Tools menu are displayed untitled Optimus 5 Optimizer File Language Tools Help Communication gt Application Template T Startup amp T Settings 11 Bar Code H T Menu amp i T Lookup Table amp T Form Aobxl Download Program F6 Download Lookup table F7 Receive data F8 bh amp B Bar Code Startup Settings Menu Lookup T able Form Download Program Download Lookup Table Heceive Data Data Optimizer Metrologic Figure 3 Tools
42. user The maximum length can contain up to 80 characters Input Type The input type property determines how data will be entered There are three options available 1 Scanner 2 Keypad 3 Both Each option will limit the manner in which data is entered To ensure that data is entered correctly be sure to consider the restrictions of each option when making the selection If the form is setup to only accept data via the keypad then it will not validate data from the scanner This is also the case should the Scanner be the option selected Selecting the Both option can eliminate potential conflict problems Prompt The Prompt property specifies the text that will appear on the display of the Optimus when the particular form is selected and active There are a maximum of eight prompts per form that can be utilized To enter information in a prompt field box click on the selected field and enter the applicable information It is important to note that information cannot be entered into this field if no data type is selected It is important to note that the information cannot be entered into this field if no data type is selected Data Type Specify the data type for each field There are 12 types available Following are the details Null Null is selected if there is no selection for the particular field If null is selected there will be no prompt displayed on the screen This is the maximum number of characters for the OptimusS and Opti
43. when the input has no match 9 1 Action when the format of the record is wrong 0 Data read amp upload y untitled Optimus S Opmizer File Language Toos Help D c Application Template r Data read amp upload Iny read date orice Iv ookup data can be uploaded Action when the format of record is wrong Stop the download process Truncate Feformat the ecord Ship the record Figure 10 Lookup Table Number Action when the input has no match Continue C Show warning message C Insert to lookup file C Show waming message amp Insert C Clear the screen Show waming amp clear screen Bij Metrologic The Lookup Table Number selection allows the developer to select lookup table 1 through 3 Field property Setting specifies whether the data field will be fixed length or have a delimiter to separate the data If a delimiter is specified the developer will be required to denote the specific ASCII code character that will serve as the delimiter The default value is 44 which is a comma Using the arrow keys the developer can scroll through the values and their associated character 19 Application Creation Lookup Table properties cont Number of fields Setting specifies the number of fields in the lookup table Field The position of the field in the lookup table that is being defined Offset The Offs
44. within the bar code is encoded The system number 1 is the new UPCE extension to the ordinary UPCE system number 0 The developer can enable the Optimus to transmit the system number of the bar code Transmit Checksum If this parameter is enabled the checksum characters will be transmitted together with the data Note f the checksum is incorrect the bar code won t be read UPC E Addon Enable UPC E Addon 2 Enables the UPCE 2 digit addon supplemental to be scanned and decoded with the UPCE code Enable UPC E Addon 5 Enables the UPCE 5 digit addon supplemental to be scanned and decoded with the UPCE code UPCA UPC A is a 12 digit numeric bar code type UPC A symbols consist of 11 data digits and one check digit The first digit is a number system digit that normally represents the type of product being identified Transmit UPCA System Number If this parameter is enabled the system UPCA number first digit will be included in the data being transmitted Transmit UPCA System Number Transmit UPCA Checksum If this parameter is enabled the UPCA checksum character last digit will be included in the data being transmitted Convert UPCA to EAN 13 v Transmit UPCA Checksum Convert UPCA to EAN13 If this parameter is enabled the UPCA code Figure 20 will be expanded to EAN13 and follow the settings of EAN13 29 Application Creation Startup The Startup properties are the initial settings that will be
45. xed even number of digits when reading 2 of 5 symbols The number of digits are usually pre defined for a particular application and all readers used in the application are programmed to only accept I 2 of 5 bar codes of the chosen length Shorter data can be left padded with zeros to fit the proper length Interleaved 2 of 5 optionally allows for a weighted modulo 10 check character for special situations where data security is important Industrial 25 Start Stop Selection v Enable Industrial 25 This parameter provides the readability of all 25 code variants For example flight tickets actually use an Industrial 25 bar code but with Interleave 25 start stop In order to read this bar code the start stop selection parameter of Industrial 25 should be set to Interleave 25 r Start Stop Selection Length Qualification Industrial 25 C Interleave 25 C Matrix 25 Fixed Length Max Min Length m Checksum p Length 127 Verify Checksum Max Length Checksum Verification fi IV Transmit Check Min Length Specifies whether the scanner will perform ta lc pln checksum verification when decoding bar codes If the checksum is incorrect the bar Figure 12 code will not be read 22 Application Creation Bar code properties cont Checksum Transmission Specifies whether the checksum characters are included in the data being transmitted Code Length
46. zer gives users the ability to define their own data collection templates quickly and easily on a PC without writing any program code In minutes a new application can be designed on screen downloaded to the terminal and begin being used The Optimizer program alone is a powerful SW tool for any program developer but there are utilities that work in conjunction with Optimizer that make it even more robust The capabilities of the extra utilities include the ability to setup real time lookups access point echoing and more The tools are included on the CDROM with the Optimizer program and are installed under the c Program Files Optimizer directory when the Optimizer installation is completed Utilities OP Load exe Enables the customer to send the user created program to the Optimus ProgLoad exe Allows the updated runtimes to be loaded Data Read exe Used to name the data file and then receive data from the Optimus to the PC DLookup exe Allows the user to load a lookup file to the Optimus TCPServer exe Used to capture sample data from an access point during an echo DataOptimizer Used to interface with an existing database for real time lookups and data updates The menu options available change based on the terminal type being utilized The available terminal types are the OptimusS OptimusR OptimusS WLAN and OptimusR WLAN Introduction Common Terms Database Table Record Field F
Download Pdf Manuals
Related Search
Related Contents
ACTIVITY: Section 6 - Patient Assessment & Troubleshooting mavolcanoplot Mirage Micro™ LG LS720 Getting Started Guide (Spanish) "user manual" GEWAN 4.5 Benutzerhandbuch für Kommunen Philips AVENT SCF277 Mag-Bind®Stool DNA 96 Kit - Omega Bio-Tek Trumatic C 6002 EH - Campingcar Copyright © All rights reserved.
Failed to retrieve file