Tripp Lite INTERNET500I

image

Contents

1. Owner s Manual TRIPLE Bisa ab 1111 W 35th Street Standby UPS Systems 230V Chicago IL 60609 USA Customer Support 1 773 869 1234 ES PANO L p 7 www tripplite com FRANCAIS p 13 p 2 Quick Installation p 3 4 Basic Operation p 4 5 Storage amp Service p 6 Specifications Copyright 2000 Tripp Lite All rights reserved This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems UPS Location Warnings e Install your UPS indoors away from excess moisture heat dust and direct sunlight e For best performance keep the indoor temperature between O C and 40 C between 32 F and 104 F e Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS to a grounded AC power outlet Do not remove or modify the ground pin of the UPS s plug Do not use plug adapters that would circumvent the UPS s ground connection Do not plug your UPS into itself this will damage the UPS and void your warranty e If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alt
2. flashing Setting Advantages Continues to charge the battery when power is present while turning OFF the inverter to prevent battery backup operation when equipment is not in use Use this momentary switch to do three things Silence the UPS alarm Move this switch to the left and release it Note When the battery is nearly depleted the alarm resumes and cannot be silenced to alert you to immediately shut down connected equipment The UPS alarm consists ofa series of short beeps followed by a brief pause The alarmis activated when the UPS switches to battery during a blackout or brownout Test your UPS s battery charge With your connected equipment and your UPS turned ON move this switch to the left hold it there for 2 seconds and release it The UPS will beep and flash its LEDs as it momentarily switches to battery to test its charge If the UPS alarm sounds afterwards or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Tf your model is not equipped with this switch you can still test your UPS batteries First plug your UPS into a grounded surge suppressor which will maintain the ground connection then turn the surge suppressor s power switch
3. Lite software and cabling to automatically save Available open files and shut down equipment during a blackout This port on a sends contact closure signals to indicate line fail and low models battery status It also receives a shut down signal from the connected computer to conserve the UPS battery charge Contact Tripp Lite Customer Support for more information 5 Storage amp Service Storage First turn your UPS OFF and disconnect its power cord from the wall outlet Then disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning your UPS to Tripp Lite contact your local Tripp Lite dealer or distributor You will be referred to a service center Carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt Specifications Internet 300 Internet 500 Output Capacity VA Watts 300 185 500 280 Battery Runtime Half Load Full Load Minutes 17 5 17 5 Typical Runtime Desktop PC 15 in monitor Minutes 15 30 Battery Recharge R
4. OFF Cold Start your UPS If your UPS is equipped with a MUTE TEST switch you may cold start it and use it as a stand alone power source when utility power is not present providing that the UPS s battery is charged To cold start your UPS first turn the OFF ON switch ON Then move the MUTE TEST switch to the left hold momentarily and release when the fj indicator light begins to flash Chronic mild brownouts that cause the UPS to switch to battery power frequently could leave your batteries low on charge The adjustable voltage potentiometer allows you to prevent excessive NORM ddd battery drain by lowering the voltage point at which the UPS switches to battery To keep your UPS from switching to battery 6 Available onselect during mild brownouts turn the potentiometer clockwise to lower models the voltage point as much as 18 below the nominal setting of 190 volts when set fully clockwise Note Your UPS s optimal setting will depend on the voltage conditions in your area Adjust the potentiometer clockwise only if you want to reduce how often your UPS switches to battery Your UPS will Junction properly at any setting Use caution when adjusting the potentiometer while the UPS is powering voltage sensitive loads Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will turn ON whenever your UPS is plugged in and receiving n
5. ate 2 4 hrs 2 4 hrs Approvals UL CE UL CE Modem Fax Protection starts at 260V 1 line 1 line Internet 700 Output Capacity VA Watts 700 425 Battery Runtime Half Load Full Load Minutes 17 5 Typical Runtime Desktop PC 15 in monitor Minutes 45 Battery Recharge Rate 2 4 hrs Approvals UL CE Modem Fax Protection starts at 260V 1 line ALLMODELS Input Voltage Frequency 230V 60 Hz On Battery Output Voltage Range 230V 5 Output Waveform Line Mode filtered sine wave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp Bstandards AC Noise Attenuation gt 40 dB AC Protection Modes H to N Hto G Nto G Wiring Diagram WireColor Wire1 We Wire3 gt American Black White Green Green Yellow Wire Reference Wiret American finen Neur Ground European Line 1 Line 2 or Neutral Ground Yellow
6. er the performance of a life support device e Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object e The UPS batteries are recyclable Refer to local codes for disposal requirements Do not dispose of the batteries in a fire e Do not attempt to add external batteries Quick Installation D Connect your computer to the UPS and the UPS to an electrical outlet 1 Unplug your computer s power cord from both your AC outletand your computer s AC input 2 Insertthe female plug of your computer s cord B into your UPS s AC input Insert the male plug of your computer s cord into your AC outlet 3 Find the power cord that came with your UPS A Insert the UPS cord s female plug int
7. o your computer s AC input Insert the UPS cord s male plug into any of your UPS s female output receptacles 2 Plug your equipment into the UPS s outlets Cords and receptacle adapters are available from EEE Tripp Lite to accommodate mostoutletconfigura tions If rewiring is necessary refer to the Wire Color Code Chart in Specifications pg 6 Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors to the battery supported outlets 3 Set your UPS s OFF ON Switch USA Canada amp Western Europe e Set it and leave it ON at all times All Other Countries e Setto OFF when you are not using connected equipment WARNING When set to OFF UPS will not provide battery backup during a blackout or brownout e Setto ON when youare using connected equipment See Basic Operation section for the Switch Function UPS Conditions and Setting Advantages Optional Installation Seas Select models OPTION 1 Phone Line Surge Suppression t TETHER Using telephone cords connect your wall jack to the UPS jack marked LINE or IN Connect your equipment to the UPS jack marked EQUIP or OUT OPTION 2 UPS Software Using Tripp Lite cable if supplied connect the DB9 port of your c
8. omputer to the DB9 port of your UPS B Load software if supplied and run installation E program appropriate for your operating system me EST oa a en t These connections and settings are optional Your UPS will function properly without these connections and settings f Make sure the equipment you connect to the UPS s telephone jacks is also protected against surges onthe AC line Continued Optional Installation continued OPTION 3 Brownout Voltage Adjustment Adjust the Voltage Potentiometer UPS back panel clockwise to lower the voltage point at which the UPS switches from on line to battery output Your UPS will function properly without these connections or settings Use caution when adjusting the potentiometer while the UPS is powering a voltage sensitive load Basic Operation Switches MUTE TEST Available on select models With your UPS plugged in set this switch according to the recommendations in Step 3 of the Quick Installation section ON Position Function ENABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The v indicator light is illuminated Setting Advantages Provides battery backup during blackouts or brownouts OFF Position Function DISABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The ve indicator light is illuminated The amp indicator light is
9. ormal AC line power This red light will turn ON when your UPS is providing your equipment with battery power This yellow light will turn ON after you test your UPS battery s charge with the Mute Test Switch to indicate that the UPS s battery is less than fully charged If it stays on continuously Available contact Tripp Lite for service The light will flash after you set the onselect OFF ON Switch to the OFF position to indicate that the UPS me will not provide battery backup during a blackout or brownout Other UPS Features AC Receptacles The receptacles provide your connected equipment with AC line gt power during normal operation They will provide battery power ele during blackouts and brownouts only if the OFF ON Switch is set to the ON position The receptacles also protect your equipment against damaging surges and line noise RJ11 Telephone Jacks These jacks protect your equipment against telephone line surges Connecting your equipment to these jacks is optional Your UPS will still work properly without this connection Battery Replacement Door Under normal conditions the original battery in your UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 DB9 Serial Port i The DB9 port connects your UPS to any workstation or server Use with Tripp