Home
Tripp Lite SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
Contents
1. Pb Vous pouvez vous rendre sur le site Web de Tripp Lite pour des informations actualis es sur le recyclage des batteries et des produits Tripp Lite Veuillez suivre ce lien http www tripplite com en support recycling program cfm La politique de Tripp Lite en est une d am lioration continue Les sp cifications du produit sont sujettes changements sans pr avis Remarque au sujet de l tiquetage Deux symboles sont utilis s sur l tiquette V Tension CA Tension CC TRIPP LITE POWER PROTECTION Mendes Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 36 13 12 130 93 328A revB 13 12 130 93328A indb 36 1 6 2014 2 59 45 PM
2. button for one second The alarm will beep once briefly after one second has passed Release the button 13 12 130 93328A indb 5 1 6 2014 2 59 21 PM Optional Installation These connections are optional Your UPS will function properly without these connections El USB and RS 232 Serial Communications all models Use the included USB cable see EX and or DB9 serial cable see FE to connect the communication port on your computer to the communication port of your UPS Install on your computer the Tripp Lite PowerAlert Software appropriate to your computer s operating system Your UPS may feature additional communications ports these ports may also be connected to additional computers which have PowerAlert Software installed Consult your PowerAlert manual for more information EJ EPO Port Connection all models This optional feature is only for those applications which require connection to a facility s Emergency Power Off EPO circuit When the UPS is connected to this circuit it enables emergency shutdown of the UPS s inverter Using the cable provided connect the EPO port of your UPS see Ef to a user supplied normally closed or normally open switch according to the circuit diagram see AB The EPO port is not a phone line surge suppressor do not connect a phone line to this port 13 12 130 93328A indb 6 000000007 Em n deno BOO e SN Se 100000 L Q00000000000000000000000
3. Ground Screw Use this to connect any equipment that requires a chassis ground o L Storage and Service Storage Before storing your UPS turn it completely OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDBY button for one second an alarm will beep once briefly after the interval has passed then unplug the UPS from the wall outlet If you store your UPS for an extended period of time recharge the UPS batteries once every three months plug the UPS into a wall outlet allow it to charge for 12 hours and then unplug it and place it back in storage Note after you plug the UPS in it will automatically begin charging its batteries however it will not supply power to its outlets see Quick Installation section If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service A variety of Extended Warranty and On Site Service Programs are available from Tripp Lite For more information on service visit www tripplite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support 3 If the problem requires service visit www tripplite co
4. OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH 5 JUMPER OPTION 2 USER SUPPLIED NORMALLY OPEN SWITCH N O EPO SWITCH NO CONNECTION 1 6 2014 2 59 23 PM Basic Operation LED Interface Buttons Front Panel ON OFF STANDBY Button To turn the UPS ON with the UPS plugged into a live AC wall outlet press and hold the ON OFF STANDBY button for one second Release the button If utility power is absent you can cold start the UPS i e turn it ON and supply power for a limited time from its batteries by pressing and holding the ON OFF STANDBY button for one second To turn the UPS OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDBY button for one second Then unplug the UPS from the wall outlet The UPS will be completely OFF After you plug the UPS into a live AC outlet the UPS in Standby mode will automatically charge its batteries but will not supply power to its outlets until it is turned ON The alarm will beep once briefly after the indicated interval has passed If fully charged MUTE TEST Button To Silence or Mute UPS Alarms briefly press and release the MUTE TEST button To Run a Self Test with your UPS plugged in and turned ON press and hold the MUTE TEST button for two seconds Continue holding the button until the alarm beeps several times and the UPS performs a self test See Results of a Self Test be
5. ce produit sans l autorisation expresse de l autorit responsable de la conformit pourrait annuler le droit de l utilisateur d utiliser cet quipement Ce dispositif est conforme la partie 15 des r glements de la FCC Le fonctionnement est sujet aux 2 conditions suivantes 1 Ce dispositif peut causer des interf rences nuisibles et 2 ce dispositif peut accepter les interf rences recues y compris les interf rences qui peuvent causer un fonctionnement ind sirable Num ros d identification de certification de conformit des fins de certification de conformit r glementaire et d identification un num ro de s rie unique a t attribu votre produit Tripp Lite Le num ro de s rie ainsi que toutes les marques d homologation et les informations requises se trouvent sur la plaque signal tique du produit Lorsque vous demandez des informations concernant la conformit de ce produit reportez vous toujours au num ro de s rie Le num ro de s rie ne doit pas tre confondu avec le nom de la marque ou le num ro de mod le du produit Recyclage de l onduleur et des batteries Veuillez recycler les produits Tripp Lite Les batteries utilis es dans les produits Tripp Lite sont des batteries au plomb scell es Ces batteries sont hautement recyclables Se reporter aux codes locaux pour les exigences en ce qui a trait l limination Vous pouvez appeler Tripp Lite pour des informations concernant le recyclage au 1 773 869 1234
6. que cumple con los l mites para un dispositivo digital Clase A de acuerdo con la parte 15 de los Reglamentos de FCC Estos l mites est n dise ados para proporcionar una protecci n razonable contra interferencia da ina cuando opere en un entorno comercial Este equipo genera usa y puede radiar energ a de radiofrecuencia y si no se instala y usa de acuerdo con el manual de instrucciones puede causar interferencia a las radiocomunicaciones La operaci n de este equipo es probable que cause interferencia da ina en cuyo caso se solicitar al usuario corregir la interferencia a su costa El usuario debe usar cables y conectores blindados con este producto Cualquier cambio o modificaci n a este producto no aprobada expresamente por la parte responsable del cumplimiento puede invalidar la autoridad del usuario para operar el equipo AVISO DE FCC SOBRE INTERFERENCIA DE RADIO TV PARA MODELOS CLASE B Nota Este equipo ha sido probado y se encontr que cumple con los l mites para un dispositivo digital Clase B de acuerdo con la parte 15 de los Reglamentos de FCC Estos l mites est n dise ados para proporcionar una protecci n razonable contra interferencia da ina en una instalaci n residencial Este equipo genera usa y puede radiar energ a de radiofrecuencia y si no se instala y usa de acuerdo con el manual de instrucciones puede causar interferencia a las radiocomunicaciones Sin embargo no hay garant a que no ocurra interferencia en una
7. stico Si el LED permanece encendido solicite servicio a Tripp Lite Si su UPS requiere reemplazo de la bater a visite www tripplite com para localizar la bater a de remplazo espec fica de Tipp Lite para su UPS 20 13 12 130 93328A indb 20 1 6 2014 2 59 37 PM Recept culos de CA Su UPS cuenta con tomacorrientes de CA de 15 amperes Estos tomacorrientes alimentan a su equipo conectado con energ a de l nea CA durante la operaci n normal y energ a de la bater a durante apagones y ca das de voltaje El UPS protege al equipo conectado a estos tomacorrientes contra sobretensiones da inas y ruido en la l nea Si usted tiene una conexi n serial o USB a su UPS puede reiniciar el equipo conectado en forma remota NEMA 5 15R encendiendo y apagando los tomacorrientes usando el Programa PowerAlert de Tripp Lite Modelos selectos tienen sus tomacorrientes divididos en uno o m s bancos de carga their etiquetados LOAD 1 etc que pueden ser apagados y encendidos en forma remota usando del software para UPS de Tripp Lite sin interrumpir la energ a al equipo conectado a los otros tomacorrientes Modelos selectos cuentan con tomacorrientes especiales identificados con claridad en el panel posterior que proporcionan solamente protecci n contra sobretensiones sin respaldo por bater a dise ados para impresoras l ser y otros dispositivos de alto consumo Modelos selectos cuentan adem s con tomacorrientes etiquetados UNSWITCHED Si
8. voir l tape 3 ci dessous Note L onduleur fonctionnera correctement d s le d marrage d initialisation cependant le fonctionnement maximum de la batterie de l unit ne sera accessible qu apr s avoir t recharg e durant 24 heures Fl Brancher l quipement l onduleur l onduleur n est con u que pour supporter l quipement lectronique Ponduleur deviendra surcharg si la valeur VA nominale totale pour tout l quipement branch exc de la capacit de sortie de l onduleur Pour d terminer la valeur VA nominale de l quipement voir sa plaque SMART1000RM1U signal tique Si la valeur est indiqu e en Illustr e amp res multiplier le nombre d amp res par 120 pour d terminer la valeur VA Exemple 1 amp re x 120 120 VA Si vous n tes pas s r e d avoir surcharg les sorties de l onduleur consultez la description OUTPUT LOAD LEVEL niveau de charge des sorties y ili T El Mettre l onduleur sous tension Appuyer et maintenir le bouton ON OFF STANDBY marche arr t attente pendant une seconde L alarme se fera entendre bri vement une fois apr s le d lai d une seconde Rel cher le bouton 29 13 12 130 93328A indb 29 1 6 2014 2 59 44 PM Installation facultative Ces connexions sont facultatives L onduleur fonctionnera correctement sans ses connexions El Communication en s rie USB et RS 232 tous les modeles B85 em D0 0000000 0000
9. OUVERT ins FOURNI PAR L UTILISATEUR parasurtenseur de ligne t l phonique ne pas A brancher une ligne t l phonique a ce port AUCUNE CONNEXION AUCUNE CONNEXION Op ration de base Interface DEL 13 12 130 93328A indb 30 1 6 2014 2 59 44 PM Fonctionnement de base suite Boutons panneau avant Bouton ON OFF STANDBY marche arr t attente Pour mettre l onduleur sous tension avec l onduleur branch dans une prise murale CA sous tension appuyer et maintenir le bouton ON OFF STANDBY marche arr t attente pendant une seconde Rel cher le bouton Si l alimentation lectrique est absente l onduleur peut tre d marr froid c d le mettre en marche et fournir du courant pendant une p riode de temps limit e partir de ses batteries en appuyant et en maintenant le bouton ON OFF STANDBY pendant une seconde Pour mettre l onduleur hors tension avec l onduleur sous tension et recevant du courant du secteur appuyer et maintenir le bouton ON OFF STANDBY marche arr t attente pendant une seconde D brancher ensuite l onduleur de la prise murale The UPS will be completely OFF Apr s avoir branch l onduleur dans une prise de courant CA sous tension l onduleur en mode Standby attente va automatiquement charger ses batteries mais ne va pas alimenter ses sorties jusqu ce qu il soit mis sous tension l alarme se fera bri vement enten
10. Para silenciar o Enmudecer las alarmas del UPS oprima brevemente y libere el bot n MUTE TEST Para ejecutar un Autodiagn stico con su UPS enchufado y encendido oprima y sostenga por dos segundos el bot n MUTE TEST Contin e sosteniendo el bot n hasta que la alarma suene varias veces y el UPS ejecute un autodiagn stico Vea a continuaci n Resultados de un Autodiagn stico Nota puede dejar equipo conectado durante un autodiagn stico No obstante su UPS no ejecutar un autodiagn stico si no est encendido consulte la descripc n del Bot n ON OFF STANDBY PRECAUCI N No desconecte su UPS para probar las bater as Esto eliminar la conexi n segura a tierra y puede introducir una sobretensi n da ina en las conexiones de su red Resultados de un Autodiagn stico La prueba durar aproximadamente 10 segundos mientras el UPS conmuta a bater a para probar su capacidad de carga y la carga de la bater a e Si el LED OUTPUT LOAD LEVEL Nivel de Carga de Salida permanece encendido en rojo y la alarma continua sonando despu s de la prueba los tomacorrientes del UPS est n sobrecargados Para eliminar la sobrecarga desconecte algunos de sus equipos y corra repetidamente el autodiagn stico hasta que el LED OUTPUT LOAD LEVEL Nivel de Carga de Salida ya no permanezca encendido y la alarma ya no suene iPRECAUCI N Cualquier sobrecarga que no sea corregida de inmediato por el usuario siguiendo un au
11. autom ticamente a cargar sus bater as sin embargo no suministrar energ a a sus tomacorrientes ver secci n de Instalaci n R pida Si usted deja sus bater as del UPS descargadas por un per odo prolongado sufrir n una p rdida permanente de capacidad Servicio t cnico Tripp Lite tambi n pone a su disposici n una variedad de Garant as extendidas y Programas de servicio t cnico en el sitio Si desea m s informaci n sobre el servicio t cnico visite www tripplite com support Antes de devolver su producto para servicio t cnico siga estos pasos 1 Revise la instalaci n y los procedimientos de operaci n que se encuentran en este manual para asegurarse de que el problema de servicio no se debe a una mala lectura de las instrucciones 2 Si el problema persiste no se comunique ni devuelva el producto al mayorista En cambio visite www tripplite com support 3 Si el problema exige servicio t cnico visite www tripplite com support y haga clic en el enlace Devoluciones de productos Desde aqu puede solicitar un n mero de Autorizaci n de Material Devuelto RMA que se necesita para el servicio t cnico En este sencillo formulario en l nea se le solicitar n los n meros de serie y modelo de la unidad junto con otra informaci n general del comprador El n mero RMA y las instrucciones para el env o se le enviar n por correo electr nico La presente garant a no cubre ning n da o directo indirecto especial o cons
12. circuito N C EPO SWITCH OPCI N 2 INTERRUPTOR NORMALMENTE ABIERTO ver PB El puerto de EPO no es un PROPORCIONADO POR EL USUARIO supresor de sobretensiones de l nea Me ERG SWITCH telef nica no conecte una l nea telef nica a este puerto SIN CONEXI N Operaci n B sica Interfaz LED 13 12 130 93328A indb 18 1 6 2014 2 59 36 PM Operacion B siCa continuaci n Botones Panel Frontal Bot n ON OFF STANDBY Para encender el UPS con el UPS enchufado en una toma de CA energizada de pared oprima y sostenga por un segundo el bot n ON OFF STANDBY Suelte el bot n Si no hubiera energ a de la red p blica usted puede arrancar en fr o el UPS i e enci ndalo y suministre energ a de sus bater as por un tiempo limitado oprimiendo y sosteniendo por un segundo el bot n ON OFF STANDBY Para apagar el UPS con el UPS encendido y recibiendo energ a de la red p blica oprima y sostenga por un segundo el bot n ON OFF STANDBY Despu s desconecte el UPS del tomacorriente de la pared El UPS se apagar completamente Despu s de conectar el UPS en un tomacorriente de CA activo el UPS en modo de espera cargar autom ticamente sus bater as pero no suministrar energ a a sus tomacorrientes hasta que se encienda La alarma sonar brevemente una vez despu s de transcurrido el intervalo indicado Si est n completamente cargadas Bot n MUTE TEST
13. may not be remotely switched off See software instructions for details Communications Ports USB or RS 232 These ports connect your UPS to any workstation or server Use with Tripp Lite s PowerAlert Software and included cables to enable your computer to automatically save open files and shut down equipment during a blackout Also use PowerAlert Software to monitor a wide variety of AC line power and UPS operating conditions Consult your PowerAlert Software manual or contact Tripp Lite Customer Support for more information See USB and RS 232 Serial Communications in the Optional Installation section for installation instructions EPO Emergency Power Off Port Your UPS features a EPO port that may be used to connect the UPS to a contact closure switch to enable emergency inverter shutdown See Optional Installation Accessory Slot Remove the small cover panel from this slot to install optional accessories to remotely monitor and control your UPS Refer to your accessory s manual for installation instructions Contact Tripp Lite Customer Support at 773 869 1234 for more information including a list of available SNMP network management and connectivity products Power Sensitivity Adjustment This dial is normally set fully counter clockwise which enables the UPS to provide maximum protection against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to providing sine wave power fro
14. oxide Do not connect surge suppressors or extension cords to the output of the UPS This might damage the UPS and may affect the surge suppressor and UPS warranties 13 12 130 93328A indb 2 1 6 2014 2 59 12 PM Important Safety Instructions Battery Warnings e Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or visit www tripplite com UPSbatteryrecycling for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com support battery index cfm to locate the specific replacement battery for your UPS The RBC Type can also be found on the label affixed to the Battery Retention Plate During hot swap battery replacement the UPS will not provide backup power in the event of a blackout or other power interruptions Do not operate the UPS without batteries e Serv
15. the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC rules Operation is subject to the following 2 conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen
16. 060000000 Q0000000000000000000000000000000 Utiliser le c ble USB inclus voir EES et ou le c ble de s rie DB9 voir EE pour connecter le port de communication de l ordinateur au port de communication de l onduleur Sur l ordinateur installer le logiciel PowerAlert de Tripp Lite compatible avec le syst me d exploitation de l ordinateur Il est possible Tm que l onduleur comprenne des ports de 299 N 000 communications additionnels ces ports 8880 CI Ey w Esp n DB d Cle 7 x O00000000000000c85 peuvent aussi tre connect s a d autres 990099000900 TN ordinateurs sur lesquels le logiciel PowerAlert a n t install Consulter le manuel PowerAlert pour plus d informations Fi Connexion du port d arr t d urgence EPO tous les modeles Cette caract ristique en option se rapporte seulement aux applications qui n cessitent une connexion un circuit d arr t d urgence EPO d une installation Lorsque l onduleur est connect ce circuit cela permet la mise hors tension d urgence de l inverseur de l onduleur OPTION 1 COMMUTATEUR NORMALEMENT FERM A l aide du cable fourni brancher le port FOURNI PAR L UTILISATEUR d arr t d urgence EPO de l onduleur voir EZ ue JUMPER un commutateur fourni par l utilisateur PE normalement ferm ou normalement ouvert selon le diagramme du circuit voir EE Le port d arr t d urgence EPO n est pas un OPTION 2 COMMUTATEUR NORMALEMENT
17. 14 2 59 17 PM Mount all UPS models in an upright tower position using included hardware The user must determine the fitness of hardware and procedures before mounting All UPS Models Stand your UPS on its side with the LED Control panel at the top Attach one rack mounting ear EN to each side of the UPS using included screws El Attach the rack mounting ears to the floor with user supplied hardware Quick Installation El Plug the UPS into an outlet on a dedicated circuit NEMA 5 15P NOTE after you plug the UPS into a live PIHESHIOWII AC outlet the UPS in Standby mode will automatically charge its batteries but will not supply power to its outlets until it is turned ON see Step 3 below Note UPS system will function properly upon initial startup however maximum runtime for the unit s battery will only be accessible after it has been charged for 24 hours Fl Plug your equipment into the UPS Your UPS is designed to support only electronic equipment You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS s Output Capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA If you are unsure if you have overloaded the UPS s outlets see OUTPUT LOAD LEVEL LED description El Turn the UPS ON Press and hold the ON OFF STANDBY
18. F Deje espacio adecuado alrededor del UPS para una ventilaci n apropiada No obstruya las ventilaciones o aberturas de ventiladores Al instalar el sistema UPS en una orientaci n de torre Aseg rese de que el panel de la pantalla de LED est en la aparte superior del UPS no en la inferior No instale la unidad con su panel frontal o posterior viendo hacia abajo en cualquier ngulo El instalar de esta manera inhibir seriamente el enfriamiento interno de la unidad causando eventualmente da o al producto no cubierto por la garant a Advertencias para la Conexi n del UPS El UPS contiene su propia fuente de energ a bater a Las terminales de salida pueden estar energizadas a n cuando el UPS no est conectado a una alimentaci n de CA Conecte el UPS a un tomacorriente de CA conectado correctamente a tierra No modifique la clavija del UPS en modo alguno que pueda eliminar la conexi n a tierra del UPS No use adaptadores que eliminen la conexi n a tierra del UPS No enchufe el UPS en s mismo esto danara al UPS y anular su garant a Si est conectando el UPS a un generador de CA activado por motor debe probarse que el generador proporciona una salida de grado computadora filtrada y con frecuencia regulada Conectar el UPS a un generador anular el Seguro M ximo de por Vida Advertencias para la Conexi n del Equipo No se recomienda el uso de este equipo en aplicaciones de soporte de vida en d
19. Hacer contacto con cualquier parte de una bater a conectada a tierra puede causar un choque el ctrico La posibilidad de dicha descarga puede reducirse si dichas conexiones a tierra son retiradas durante la instalaci n y mantenimiento aplicable al equipo y alimentaciones remotas por bater a que no tengan un circuito de alimentaci n aterrizado Para equipo enchufable el tomacorriente deber instalarse cerca del equipo y deber ser f cilmente accesible 15 13 12 130 93328A indb 15 1 6 2014 2 59 27 PM Instalacion Rack Instale su equipo en rack de 4 postes 6 2 postes o en un gabinete vea a continuaci n para la instalaci n en 2 postes Antes de la instalaci n el usuario debe determinar la adecuaci n de los accesorios y procedimientos Si los accesorios y procedimientos no son adecuados para su aplicaci n p ngase en contacto con el fabricante de su rack o gabinete Los procedimientos descritos en este manual son para tipos comunes de racks y gabinetes y pueden no ser apropiados para todas las aplicaciones Nota Las ilustraciones pueden diferir de su modelo Instalaci n en 4 Postes Todos los modelos de UPS incluyen los accesorios requeridos para instalar en un rack de 4 postes 1 Instale las orejas de instalaci n EM en los orificios frontales de instalaci n de su equipo El usando los tornillos suministrados M Las orejas deben apuntar al frente El Usando un ayudante si fuera necesario levante su equipo
20. Owner s Manual S y SmartPro 1U Rackmount Intelligent Line Interactive UPS Systems 120V Output 500VA 1000VA SMART500RT1U SMART750RM1U SMART1000RM1U Series AG 0097 Series AGSM8269 Series AGSM5060 Not suitable for mobile applications Important Safety Instructions 2 Mounting 4 Quick Installation 5 Optional Installation 6 Basic Operation 7 Storage and Service 10 Battery Replacement 11 Warranty Registration 12 Espa ol 13 Francais 25 TRIPP LITE POWER PROTECTION MED Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite 13 12 130 93328A indb 1 1 6 2014 2 59 12 PM Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation operation and storage of this product Failure to heed these warnings may affect the warranty UPS Location Warnings Use caution when lifting the UPS Because of the considerable weight of all rackmount UPS systems at least two people should assist in lifting and installing them e Install the UPS indoors away from excess moisture or heat dust or direct sunlight For best performance the ambient temperature near the UPS should be between 0 C and 40 C between 32 F and 104 F Leave adequate space around all sides of the UPS for pr
21. ada lado del UPS usando los tornillos incluidos El Fije las orejas de instalaci n del rack al piso con los accesorios suministrados por el usuario Instalaci n R pida Fa Enchufe el UPS en un tomacorriente en un circuito NEMA 5 15P Se dedicado Muestra Clavija iNota Despu s de conectar el UPS en un tomacorriente activo de CA el UPS en modo de espera cargar autom ticamente sus bater as pero no suministrar energ a a sus tomacorrientes hasta que se encienda ver paso 3 a continuaci n Nota El sistema UPS funcionar adecuadamente desde la puesta en marcha inicial no obstante la autonom a m xima de la bater a de la unidad solo se alcanzar despu s de que se haya cargado durante 24 horas Fi Enchufe su equipo en el UPS Su UPS est dise ado para soportar solamente equipo electr nico Usted sobrecargar el UPS si el valor total en VA para todo el equipo que conecte excede la capacidad de salida del UPS Para localizar los valores de VA de su equipo consulte las placas de identificaci n Si el equipo est especificado en amperes multiplique el n mero de amperes por 120 para determinar VA Ejemplo 1 Ampere x 120 120 VA Si no est seguro de si ha sobrecargado las salidas del UPS consulte la descripci n de LED NIVEL DE CARGA DE SALIDA El Encienda el UPS Oprima y sostenga por un segundo el bot n ON OFF STANDBY La alarma emitir un breve bip despu s de transcurrido u
22. ase suite Autres caract ristiques de l onduleur panneau arri re Prises CA L onduleur est quip de sorties CA de 15 amp res Ces prises de sortie fournissent au mat riel branch une ligne d alimentation CA lors d un fonctionnement normal et de la puissance des batteries durant les pannes de courant et les baisses de tension L onduleur prot ge l quipement branch ces prises contre les surcharges dommageables et les bruits de circuit Si un connexion USB ou de s rie est connect e l onduleur l quipement connect peut tre r initialis distance en NEMA 5 15R mettant hors tension et sous tension les prises en utilisant le logiciel PowerAlert de Tripp Lite Les prises de certains mod les sont divis es en un ou plusieurs bancs de charge tiquet s LOAD 1 etc qui peuvent tre mis sous tension et hors tension distance en utilisant le logiciel pour onduleur Tripp Lite sans interrompre l alimentation de l quipement branch aux autres prises Certains mod les sont quip s de prises sp ciales clairement tiquet es sur le panneau arri re qui fournissent une protection uniquement contre les surtensions et non pas batteries de Secours concues pour les imprimantes laser et autres dispositifs dont l appel de courant est lev Certains mod les sont galement quip s de prises tiquet es UNSWITCHED non commut e qui ne peuvent par tre mises hors tension distance Consulter les ins
23. ce that may cause undesired operation Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product UPS and Battery Recycling Please recycle Tripp Lite Products The batteries used in Tripp Lite products are sealed Lead Acid batteries These batteries are highly recyclable Please refer to your local codes for disposal requirements You can call Tripp Lite for recycling info at 1 773 869 1234 You can go the Tripp Lite Website for up to date information on recycling the batteries or any Tripp Lite product Pb Please follow this link http www tripplite com en support recycling program cfm Tripp Lite has a policy of continuous improvement Product specifications are subject to change without notice Note on Labeling Two symbols are used on the label V AC Voltage DC Voltage TRIPP LITE POWER PROTECTION Mendes Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 12 13 12 130 93328A indb 12 1 6 2014 2 59 25 PM Manual del propietario SmartPro para Ins
24. dre une fois une fois l intervalle d fini coul Si enti rement charg Bouton MUTE TEST sourdine test Pour mettre les alarmes de l onduleur en sourdine ou Mute appuyer bri vement et rel cher le bouton MUTE TEST sourdine test Pour effectuer un autotest avec l onduleur branch et sous tension appuyer et maintenir le bouton MUTE TEST sourdine test pendant deux secondes Continuer maintenir le bouton enfonc jusqu ce que l alarme se fasse entendre plusieurs fois et que l onduleur effectue un autotest Voir Results of a Self Test r sultats d un autotest ci dessous Remarque vous pouvez laisser l quipement connect durant un auto test Londuleur par contre n effectuera pas un autotest s il n est pas sous tension voir la description du bouton ON OFF STANDBY marche arr t attente ATTENTION Ne pas d brancher l onduleur pour v rifier ses batteries Cela aura pour effet d liminer la mise la terre de s curit et risque d introduire une surtension dommageable dans les connexions de r seau R sultats d un autotest Le test dure environ 10 secondes et l onduleur passe en mode batteries pour tester sa capacit de charge et la charge de la batterie Si le voyant DEL OUTPUT LOAD LEVEL niveau de charge de sortie rouge demeure allum et si l alarme continue se faire entendre apr s le test les prises de l onduleur sont surcharg es Pour liminer la surcharg
25. e vie ultime Avertissements concernant le raccordement de l quipement n est pas recommand d utiliser cet quipement dans des applications de soutien la vie o une d faillance de cet quipement est raisonnablement susceptible d entrainer la d faillance de l quipement de maintien des fonctions vitales ou d affecter de mani re importante sa s curit ou son efficacit Ne pas utiliser cet quipement dans un milieu o il existe un m lange anesth sique inflammable avec de l air de l oxyg ne ou de l oxyde nitreux Ne pas brancher de limiteurs de surtension ou de rallonges lectriques la sortie de l onduleur Cela risquerait d endommager l onduleur et d affecter le limiteur de surtension de m me que les garanties de l onduleur 26 13 12 130 93328A indb 26 1 6 2014 2 59 40 PM Consignes de s curit importantes Avertissements concernant les batteries e Les batteries peuvent pr senter un risque de d charge lectrique et de br lures caus s par les courants lev s des courts circuits Observer les pr cautions qui s imposent Ne pas jeter les batteries dans le feu Ne pas ouvrir l onduleur ou les batteries Ne pas cr er de court circuit ou de pont entre les bornes de la batterie et un quelconque objet D brancher et mettre hors tension l onduleur avant de remplacer la batterie Utiliser des outils ayant des poign es isol es Il n existe aucune pi ce r parable par l utilisateur l int rieur de l
26. e d brancher certains des appareils et effectuer l autotest plusieurs reprises jusqu ce que le voyant DEL OUTPUT LOAD LEVEL niveau de charge de sortie rouge s teigne et que l alarme ne se fasse plus entendre ATTENTION Toute surcharge qui n est pas imm diatement corrig e suite un autotest peut amener l onduleur se mettre hors tension et cesser de fournir de la puissance de sortie dans le cas d une panne d lectricit ou d une chute de tension du secteur Si le voyant DEL BATTERY WARNING avertissement de la batterie demeure allum et que l alarme continue de se faire entendre apr s le test les batteries de l onduleur ont besoin d tre recharg es ou remplac es Permettre l onduleur de se recharger sans interruption pendant 12 heures et r p ter l autotest Si le voyant DEL demeure allum contacter Tripp Lite pour obtenir du service Si les batteries de l onduleur ont besoin d tre remplac es visiter www tripplite com pour d terminer la batterie de remplacement Tripp Lite sp cifique votre onduleur alarme se fera bri vement entendre une fois une fois l intervalle d fini coul 31 13 12 130 93328A indb 31 1 6 2014 2 59 44 PM Fonctionnement de base suite T moins panneau avant Toutes les descriptions des t moins s appliquent lorsque l onduleur est branch dans une prise murale et qu il se trouve sous tension DEL POWER puissance ce t moin DEL ver
27. e montage avec 2 montants L utilisateur doit d terminer l aptitude du mat riel et des proc dures avant le montage Si le mat riel et les proc dures ne conviennent pas l application contacter le fabricant du b ti ou de l enceinte pour b ti Les proc dures d crites dans le pr sent manuel sont pour les b tis et les enceintes pour b ti de type commun et peuvent ne pas tre appropri es pour toutes les applications Remarque Les illustrations peuvent diff rer de votre mod le Montage avec 4 montants Tous les mod les d onduleur incluent le mat riel requis pour monter dans un b ti 4 montants 1 Attacher les oreilles de montage EN aux trous de montage avant de l quipement E en utilisant les vis fournies Tl Les oreilles devraient faire face vers l avant 2 Avec l assistance d une autre personne au besoin souler l quipement et le monter au b ti L attacher en vissant la quincaillerie appropri e EY travers ses oreilles de montage et dans les rails du b ti Montage avec 2 montants t l communication Monter les mod les d onduleur 1U dans des b tis 2 montants avec la quincaillerie incluse en suivant la proc dure ci dessous Si vous effectuez le montage de mod les d onduleur 2U dans des b tis 2 montants ils n cessitent l ajout d une trousse d installation de montage en b ti 2 montants Tripp Lite 2 mod le 2POSTRMKITWM vendue s par ment Consulter le manuel du p
28. e forma que el efecto en el equipo de cualquier distorsi n de forma de onda en la salida del UPS pueda evaluarse sin interrupci n de las operaciones cr ticas Breaker s de Alimentaci n todos los modelos protege n su circuito el ctrico contra sobrecorriente originada en la carga del UPS Si se dispara n este os breaker s retire algo de la carga y entonces reestabl zcalo s oprimi ndolo s Breaker de Salida Modelos selectos Su UPS cuenta con uno o m s breakers que protegen su UPS contra sobrecarga en la salida Si uno o mas breakers se dispara retire algo de la carga en el los circuito s entonces oprima el los breaker s para reestablecerlo s C e Tornillo de Conexi n a Tierra selo para conectar cualquier equipo que requiera una conexi n de tierra a chasis Almacenamiento y Servicio Almacenamiento Antes de almacenar su UPS ap guelo completamente con el UPS encendido y recibiendo energ a de la red p blica oprima y sostenga por un segundo el bot n ON OFF STANDBY sonar brevemente una alarma una vez despu s que haya transcurrido el intervalo a continuaci n desconecte el UPS del tomacorriente de pared Si almacena su UPS por un per odo prolongado de tiempo recargue las bater as del UPS una vez cada tres meses enchufe el UPS en un tomacorriente de pared permita que cargue por 12 horas y despu s descon ctelo y p ngalo nuevamente en almac n Nota despu s que enchufe el UPS empezar
29. e inst lelo en el rack Suj telo atornillando los accesorios adecuados EJ a trav s de sus orejas de instalaci n y en los rieles del rack Instalaci n en 2 Postes Telecom Instale los modelos de UPS de 1U en racks de 2 postes con los accesorios incluidos siguiendo el procedimiento descrito a continuaci n Si instala modelos de UPS de 2U en racks de 2 postes stos requieren la adici n de un Juego de Instalaci n para Rack de 2 Postes de Tripp Lite modelo 2POSTRMKITWM vendido por separado Para el procedimiento de instalaci n para modelos de UPS de 2U consulte el manual del propietario del juego de instalaci n E Instale las orejas de instalaci n EM en los orificios frontales de instalaci n de su equipo El usando los tornillos suministrados 3 Las orejas deben apuntar hacia atr s El Usando un ayudante si fuera necesario levante su equipo e inst lelo en el rack Suj telo atornillando los accesorios adecuados EJ a trav s de sus orejas de instalaci n y en los rieles del rack 13 12 130 93328A indb 16 1 6 2014 2 59 32 PM Instalacion Torre Instale todos los modelos de UPS en una posici n de torre vertical usando los accesorios incluidos Antes de la instalaci n el usuario debe determinar la adecuaci n de los accesorios y procedimientos Todos los Modelos de UPS Coloque su UPS en su sitio con el panel de LED Control en la parte superior Fije la oreja de instalaci n en rack EM a c
30. e la bater a interna se agotar eventualmente Vea a continuaci n la descripci n de LED BATTERY CHARGE Carga de Bater a LED VOLTAGE CORRECTION Correcci n de Voltaje Este LED verde se enciende continuamente el UPS est corrigiendo autom ticamente alto o bajo voltaje de CA en la alimentaci n de servicio sin el apoyo de la energ a de la bater a El UPS emitir adem s un ligero click Esto es normal son operaciones autom ticas del UPS no se requiere acci n de su parte LED de OUTPUT LOAD LEVEL Nivel de Carga de la Bater a Este LED multicolor indica la carga el ctrica aproximada del equipo conectado a los tomacorrentes de CA del UPS Cambiar de verde carga ligera a amarillo carga media a rojo sobrecarga Si el LED est rojo ya sea iluminado continuamente o destellando elimine de inmediato la sobrecarga desconectando algo de su equipo de los tomacorrientes hasta que el LED cambie de rojo a amarillo o verde iPRECAUCI N Cualquier sobrecarga que no sea corregida de inmediato por el usuario puede causar que el UPS se apague y deje de suministrar energ a de salida en caso de un apag n o ca da de voltaje LED BATTERY CHARGE Carga de Bater a cuando el UPS est operando de la energ a de la red p blica este LED indica el estado aproximado de carga de las bater as internas del UPS rojo indica que las bater as est n empezando a cargar amarillo indica que las bater as est n aproximadamente a
31. e mounting If hardware and procedures are not suitable for your application contact the manufacturer of your rack or rack enclosure The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications Note The illustrations may differ from your model 4 Post Mounting All UPS models include hardware required to mount in a 4 post rack 1 Attach mounting ears E to the front mounting holes of your equipment El using the screws provided A The ears should face forward El Using an assistant if necessary lift your equipment and mount it to the rack Attach it by screwing the appropriate hardware LJ through its mounting ears and into the rack rails 2 Post Telecom Mounting Mount 1U UPS models in 2 post racks with included hardware following the procedure below If you mount 2U UPS models in 2 post racks they require the addition of a Tripp Lite 2 Post Rackmount Installation Kit model 2POSTRMKITWM sold separately See Installation Kit owner s manual for installation procedure for 2U UPS models 1 Attach mounting ears E to the front mounting holes of your equipment El using the screws provided IJ The ears should face backward El Using an assistant if necessary lift your equipment and mount it to the rack Attach it by screwing the appropriate hardware LJ through its mounting ears and into the rack rails 13 12 130 93328A indb 4 1 6 20
32. e tout autour de l onduleur pour une ventilation ad quate Ne pas obstruer les vents ou les ouvertures du ventilateur Lorsque l onduleur est mont en tour s assurer que le panneau de l cran DEL se trouve dans la partie sup rieur de l onduleur et non pas dans la partie inf rieure Ne pas monter l appareil avec ses panneaux avant et arri re face vers le bas quel que soit l angle En montant le syst me de cette facon vous pourriez bloquer le syst me de refroidissement interne de l appareil et causer des dommages s rieux et non couverts par la garantie Avertissements concernant la connexion de l onduleur e onduleur contient sa propre source d nergie batterie Les bornes de sortie peuvent tre sous tension m me lorsque l onduleur n est pas branch une alimentation CA Brancher l onduleur une prise de courant CA correctement mise la terre Ne pas modifier la fiche de l onduleur d une facon qui pourrait liminer le raccordement la terre de l onduleur Ne pas utiliser d adaptateurs qui liminent le raccordement la terre de l onduleur Ne pas brancher l onduleur lui m me cela aura pour effet d endommager l onduleur et d annuler la garantie Si l onduleur est branch une g n ratrice CA entrain e par un moteur la g n ratrice doit fournir une tension de sortie filtr e et adapt e aux quipements informatiques Connecter l onduleur une g n ratrice aura pour effet d annuler l assuranc
33. ecuencial del producto que ocurra durante el env o a Tripp Lite o a un centro de servicio t cnico de Tripp Lite autorizado Los productos enviados a Tripp Lite o a un centro de servicio t cnico de Tripp Lite autorizado deben tener prepagos los cargos de transporte Escriba el n mero RMA en el exterior del embalaje Si el producto se encuentra dentro del per odo de garant a adjunte una copia de su recibo de venta Env e el producto para servicio t cnico mediante un transportador asegurado a la direcci n que se le proporcion cuando solicit el numero RMA 22 13 12 130 93328A indb 22 1 6 2014 2 59 37 PM Reemplazo de la Bateria Bajo condiciones normales las baterias originales de su UPS durar n muchos a os Antes de reemplazar las bater as consulte la secci n de Seguridad Las bater as est s dise adas para reemplazo Hot Swap es decir dejando el UPS encendido pero alg n personal de servicio calificado puede querer apagar el UPS y desconectar el equipo antes de proceder Procedimiento E Remueva el Panel Frontal 2 Desconecte las Bater as EJ Retire Deseche las Bater as E Coloque las Bater as Bl conecte las Bater as Acople los conectores negro con negro y rojo con rojo g Reinstale el Panel Frontal 23 13 12 130 93328A indb 23 1 6 2014 2 59 37 PM AVISO DE FCC SOBRE INTERFERENCIA DE RADIO TV PARA MODELOS CLASE A Nota Este equipo ha sido probado y se encontr
34. ed to yellow or green CAUTION Any overload that is not corrected by the user immediately may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a blackout or severe brownout this LED indicates the approximate amount of energy ultimately affecting runtime which the UPS s batteries will provide red indicates a low level of energy yellow indicates a medium level of energy and green indicates a high level of energy Since the runtime performance of all UPS batteries will gradually deplete over time it is recommended that you periodically perform a self test see MUTE TEST Button description to determine the energy level of your UPS batteries BEFORE a blackout or severe brownout occurs During a prolonged blackout or severe brownout you should save files and shut down your equipment since battery power will eventually be depleted When the LED turns red and an alarm sounds continuously it indicates the UPS s batteries are nearly out of power and UPS shut down is imminent BATTERY WARNING LED this LED lights red and an ala
35. empre Vivo que no pueden apagarse en forma remota Para detalles consulte las instrucciones del software Puertos de Comunicaciones USB o RS 232 Estos puertos conectan su UPS a cualquier estaci n de trabajo o servidor Use con el Software PowerAlert de Tripp Lite y los cables incluidos para habilitar su computadora para guardar autom ticamente archivos abiertos y apague el equipo durante un apag n Use tambi n el Software PowerAlert para monitorear una amplia variedad de condiciones de la alimentaci n de CA y operaci n del UPS Para m s informaci n consulte su manual del Software PowerAlert o p ngase en contacto con Soporte al Cliente de Tripp Lite Consulte Comunicaciones USB y Serial RS 232 en la secci n Instalaci n Opcional para las instrucciones de instalaci n Puerto EPO Emergency Power Off Apagado de Emergencia Su UPS cuenta con un puerto EPO que puede usarse para conectar el UPS a un interruptor de cierre de contacto para activar el apagado de emergencia del inversor Consulte la Instalaci n Opcional Ranura Auxiliar Retire el panel peque o de la cubierta de esta ranura para instalar accesorios opcionales para monitorear y controlar su UPS en forma remota Para instrucciones de instalaci n consulte su manual de accesorios Para m s informaci n p ngase en contacto con Soporte al Usuario de Tripp Lite al 773 869 1234 incluyendo una lista de productos disponibles de SNMP administraci n de red y conectiv
36. ent battery for your UPS The alarm will beep once briefly after the indicated interval has passed Indicator Lights Front Panel All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON POWER LED this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source The LED flashes and an alarm sounds 4 short beeps followed by a pause to indicate the UPS is operating from its internal batteries during a blackout or severe brownout If the blackout or severe brownout is prolonged you should save files and shut down your equipment since internal battery power will eventually be depleted See BATTERY CHARGE LED description below VOLTAGE CORRECTION LED this green LED lights continuously whenever the UPS is automatically correcting high or low AC voltage on the utility line J without the assistance of battery power The UPS will also emit a slight clicking noise These are normal automatic operations of the UPS no action is required on your part OUTPUT LOAD LEVEL LED this multicolored LED indicates the approximate electrical load of equipment connected to the UPS s AC outlets It will turn from green light load to yellow medium load to red overload If the LED is red either illuminated continuously or flashing clear the overload immediately by unplugging some of your equipment from the outlets until the LED changes from r
37. er e MISE EN GARDE Ne pas ouvrir ou endommager les batteries Les lectrolytes d gag s sont dangereux pour la peau et les yeux Ils peuvent tre toxiques MISE EN GARDE Une batterie peut pr senter un risque de d charge lectrique et un courant lev du court circuit Les pr cautions suivantes doivent tre observ es lorsque l on manipule les batteries o Enlever les montres les bagues ou tout autre objet m tallique o Utiliser des outils munis de poign es isol es O Porter des gants et des bottes en caoutchouc o Ne pas d poser d outils ou de pi ces m talliques sur les batteries o S assurer que la batterie n est pas accidentellement mise la terre Si la batterie est accidentellement mise la terre enlever la source de connexion la terre Tout contact avec une partie d une batterie mise la terre pourrait causer un choc lectrique La probabilit d un tel choc peut tre r duite si de telles mises la terre sont limin es durant l installation et l entretien cela s applique aux fournitures de l quipement et des batteries distance qui n ont pas de circuit d alimentation mis la terre Pour l quipement lectrique la prise de courant doit tre install e proximit de l quipement et tre facilement accessible 21 13 12 130 93328A indb 27 1 6 2014 2 59 40 PM Montage bati Monter l quipement sur un b ti 4 ou 2 montants ou une enceinte pour b ti voir ci dessous pour l
38. es batteries El Enlever jeter les batteries 4 Ajouter les batteries B Connecter les batteries Attacher les connecteurs noir avec noir et rouge avec rouge g Remettre le panneau avant en place 35 13 12 130 93328A indb 35 1 6 2014 2 59 45 PM AVIS D INTERF RENCE RADIO TV DE LA FCC POUR LES MODLES DE CLASSE A Remarque Cet quipement a t test et trouv conforme aux restrictions applicables un appareil num rique de classe A conform ment la partie 15 des r glements de la FCC Ces restrictions sont concues pour assurer une protection raisonnable contre les interf rences nuisibles quand le mat riel est utilis dans un environnement commercial Cet quipement g n re utilise et peut mettre de l nergie radiofr quence et s il n est pas install et utilis en conformit avec le manuel d instruction peut causer des interf rences nuisibles aux communications radio L utilisation de cet quipement est susceptible de causer des interf rences dangereuses auquel cas l utilisateur devra corriger les interf rences ses propres frais L utilisateur doit utiliser des c bles et des connecteurs blind s avec ce produit Tout changement ou modification apport e ce produit sans l autorisation expresse de l autorit responsable de la conformit pourrait annuler le droit de l utilisateur d utiliser cet quipement AVIS D INTERF RENCE RADIO TV DE LA FCC POUR LES MODLES DE CLASSE B Remarque Ce
39. f rents r glages du cadran faire fonctionner l quipement connect en mode test s curitaire de facon ce que l effet sur l quipement de toute distorsion harmonique au niveau de la sortie de l onduleur puisse tre valu e sans perturber les op rations essentielles 33 13 12 130 93328A indb 33 1 6 2014 2 59 45 PM Fonctionnement de base suite Disjoncteur s d entr e tous les mod les Prot ger le circuit lectrique contre la surintensit de la charge de l onduleur Si ces disjoncteurs se d clenchent enlever une partie de la charge puis r armer le s disjoncteur s en les enfoncant en place Disjoncteur de sortie certains mod les L onduleur comporte un ou plusieurs dijoncteurs qui prot gent l onduleur contre les surcharges de sortie Si un ou plusieurs disjoncteurs se d clenche nt enlever une partie de la charge sur le s circuit s puis appuyer sur le s commutateur s du disjoncteur pour le r armer Vis de mise la terre utiliser cette vis pour brancher n importe quel quipement n cessitant une mise la terre au ch ssis Owe Entreposage et entretien Entreposage Avant d entreposer l onduleur le mettre compl tement hors tension avec l onduleur sous tension et recevant du courant du secteur appuyer et maintenir le bouton ON OFF STANDBY marche arr t attente pendant une seconde une alarme se fera bri vement entendre une fois une fois l intervalle d fini coul pui
40. icing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions When replacing batteries replace with the same type and number of batteries or battery packs CAUTION Do not dispose of batteries in a fire The batteries may explode e CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries o Remove watches rings or other metal objects o Use tools with insulated handles o Wear rubber gloves and boots o Do not lay tools or metal parts on top of batteries o Determine if battery is inadvertently grounded If inadvertently grounded remove source from ground Contact with any part of a grounded battery can result in electric shock The likelihood of such shock can be reduced if such grounds are removed during the installation and maintenance applicable to equipment and remote battery supplies not having a grounded supply circuit For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible 13 12 130 93328A indb 3 1 6 2014 2 59 12 PM Mount your equipment in either a 4 post or 2 post rack or rack enclosure see below for 2 post mounting The user must determine the fitness of hardware and procedures befor
41. idad Ajuste de Sensibilidad de Energ a Esta car tula est normalmente establecida completamente en sentido opuesto a las manecillas del reloj lo que activa al UPS para proporcionar m xima protecci n contra distorsi n de forma de onda en su entrada de CA Cuando ocurra dicha distorsi n el UPS cambiar a suministrar NORM DELAY energ a de onda sinusoidal de sus reservas de bater a por el tiempo que dure la distorsi n En reas con energ a deficiente de la red p blica o en donde la energ a de alimentaci n del UPS provenga de un generador la distorsi n cr nica de forma de onda puede causar que el UPS conmute demasiado frecuentemente a respaldo por bater a descargando las reservas de la bater a Usted pude ser capaz de reducir cu n frecuentemente conmuta su UPS a respaldo por bater a debido a una distorsi n moderada de forma de onda experimentando con diferentes ajustes de esta car tula Cuando la car tula gira en sentido de las manecillas del reloj el UPS se vuelve m s tolerante a las variaciones en su forma de onda de CA de la alimentaci n NOTA Mientras m s se ajusta la car tula en el sentido de las manecillas del reloj mayor ser el grado de distorsi n de forma de onda que 21 13 12 130 93328A indb 21 1 6 2014 2 59 37 PM Operacion B sica continuaci n permitir pasar el UPS al equipo conectado Al experimentar con varios ajustes de esta car tula opere el equipo conectado en un modo de prueba seguro d
42. iles Consignes de s curit importantes 26 Montage 28 Installation rapide 29 Installation facultative 30 Op ration de base 30 Entreposage et entretien 34 Remplacement de la batterie 35 Avis 36 English 1 Espa ol 13 a TRIPP LITE POWER PROTECTION ho Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Droits d auteur O 2014 Tripp Lite Tous droits r serv s SmartPro est une marque de commerce enregistr e de Tripp Lite 13 12 130 93328A indb 25 1 6 2014 2 59 40 PM Consignes de s curit importantes CONSERVEZ CES INSTRUCTIONS Ce manuel contient des instructions importantes qui devraient tre respect es pendant l installation l utilisation et l entreposage de ce produit Le non respect de ces avertissements pourrait affecter la garantie Avertissements concernant l emplacement de l onduleur Faire preuve de prudence au moment de lever l onduleur Compte tenu du poids consid rable de tous les onduleurs mont s en b ti les op rations de levage et l installation devraient tre effectu es par au moins deux personnes e Installer l onduleur l int rieur l cart des sources de chaleur et d humidit excessives de la poussi re ou de la lumi re directe du soleil Pour un rendement optimal la temp rature ambiante proximit de l onduleur devrait se situer entre 0 C et 40 C entre 32 F et 104 F Laisser suffisamment d espac
43. instalaci n en particular Si este equipo causa interferencia da ina a la recepci n de radio o televisi n que pueda determinarse encendiendo y apagando el equipo se recomienda al usuario intentar corregir la interferencia usando una de las siguientes medidas reoriente o relocalice la antena receptora aumente la separaci n entre el equipo y el receptor conecte el equipo en un tomacorriente en un circuito distinto del que est conectado el receptor solicite ayuda al distribuidor o a un t cnico experimentado de radio televisi n El usuario debe usar cables y conectores blindados con este producto Cualquier cambio o modificaci n a este producto no aprobada expresamente por la parte responsable de compatibilidad puede invalidar la autoridad del usuario para operar el equipo Este dispositivo cumple con la parte 15 de los Reglamentos de la FCC La operaci n est sujeta a las dos condiciones siguientes 1 Este dispositivo no puede causar interferencia da ina y 2 este dispositivo debe aceptar cualquier interferencia recibida incluso interferencia que pueda causar una operaci n indeseable N meros de Identificaci n de Cumplimiento con Reglamentos Para el prop sito de certificaciones e identificaci n de conformidad regulatoria su producto Tripp Lite ha recibido un n mero de serie nico El n mero de serie se puede encontrar en la etiqueta de placa de identificaci n junto con todas las marcas e informaci n requeridas de aprobaci n A
44. l solicitar informaci n de conformidad para este producto refiera siempre el numero de serie El n mero de serie no debe confundirse con el nombre de la marca o el n mero de modelo del producto Reciclaje de UPS y Bater as Por favor recicle los productos de Tripp Lite Las bater as usadas en los productos de Tripp Lite son bater as selladas de Plomo Acido Estas bater as son altamente reciclables Refi rase por favor a sus c digos locales para requerimientos de desecho Puede llamar a Tripp Lite para reciclar informaci n al 1 773 869 1234 Pb Puede acudir al sitio Web de Tripp Lite en busca de informaci n actualizada sobre el reciclaje de bater as o cualquier producto de Tripp Lite Siga por favor este enlace http www tripplite com en support recycling program cfm Tripp Lite tiene una pol tica de mejora continua Las especificaciones del producto est n sujetas a cambio sin previo aviso Notas sobre la etiqueta Dos s mbolos se usan en la etiqueta V Voltaje de CA Voltaje de CD TRIPP LITE POWER PROTECTION cena 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 24 13 12 130 93328A indb 24 1 6 2014 2 59 38 PM Manuel de lutilisateur Montage en b ti 1U SmartPro Onduleurs intelligents interactifs en ligne Sortie de 120 V 500 1 000 VA SMART500RT1U SMART750RM1U SMART1000RM1U S rie AG 0097 S rie AGSM8269 S rie AGSM5060 Ne convient pas aux applications mob
45. la mitad de la carga y verde indica que las bater as est n completamente cargadas Cuando el UPS est operando con energ a de la bater a durante un apag n o reducci n severa se voltaje este LED indica la cantidad aproximada de energ a lo que finalmente afectan la autonom a que proporcionar n las bater as del UPS rojo indica un bajo nivel de energ a amarillo indica un nivel medio de energ a y verde indica un alto nivel de energ a Ya que el rendimiento de autonom a de todas las bater as de UPS se agotar gradualmente a trav s del tiempo es recomendable que usted realice un autodiagn stico peri dico ver descripci n de Bot n MUTE TEST para determinar el nivel de energ a de sus bater as del UPS ANTES que ocurra un apag n o reducci n severa de voltaje Durante un apag n o reducci n severa de voltaje prolongados debe guardar sus archivos y apagar su equipo ya que la energ a de la bater a se agotar eventualmente Cuando el LED se pone rojo y suena continuamente una alarma indica que las bater as del UPS est n pr ximas a agotarse y es inminente el apagado del UPS LED BATTERY WARNING ADVERTENCIA DE BATER A este LED se enciende en rojo y suena una alarma en forma intermitente despu s que usted inicie un autodiagn stico Vea descripci n del Bot n MUTE TEST para indicar que las bater as del UPS recesitan ser recargadas o reemplazadas Permita al UPS recargar continuamente por 12 horas y repita el autodiagn
46. low Note you can leave connected equipment on during a self test Your UPS however will not perform a self test if the UPS is not turned on see ON OFF STANDBY Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and battery charge e If the OUTPUT LOAD LEVEL LED remains lit red and the alarm continues to sound after the test the UPS s outlets are overloaded To clear the overload unplug some of your equipment and run the self test repeatedly until the OUTPUT LOAD LEVEL LED is no longer lit red and the alarm is no longer sounding CAUTION Any overload that is not corrected by the user immediately following a self test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout 13 12 130 93328A indb 7 1 6 2014 2 59 23 PM Basic Operation continuea e If the BATTERY WARNING LED remains lit and the alarm continues to sound after the test the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED remains lit contact Tripp Lite for service If your UPS requires battery replacement visit www tripplite com to locate the specific Tripp Lite replacem
47. m its battery reserves for as NORM DELAY long as the distortion is present In areas with poor utility power or where the UPS s input power comes from a backup generator chronic waveform distortion could cause the UPS to switch to battery too frequently draining its battery reserves You may be able to reduce how often your UPS switches to battery due to moderate waveform distortion by experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion the UPS will allow to pass to connected equipment When experimenting with different settings for this dial operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations 9 13 12 130 93328A indb 9 1 6 2014 2 59 23 PM Basic Operation continuea Input Breaker s all models Protect your electrical circuit from overcurrent draw from the UPS load If these breakers trip remove some of the load then reset them by pressing the breaker s in Output Breaker select models Your UPS features one or more breakers that protect your UPS from output overload If one or more breakers trip remove some of the load on the circuit s then reset them by pressing the breaker switch es in
48. m support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This simple on line form will ask for your unit s model and serial numbers along with other general purchaser information The RMA number along with shipping instructions will be emailed to you Any damages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center are not covered under warranty Products shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its warranty period enclose a copy of your sales receipt Return the product for service using an insured carrier to the address given to you when you request the RMA 13 12 130 93328A indb 10 1 6 2014 2 59 24 PM Battery Replacement Under normal conditions the original batteries in your UPS will last many years See Safety section before replacing batteries The batteries are designed for hot swap replacement i e leaving the UPS in ON mode but some qualified service personnel may wish to put the UPS in the OFF mode and disconnect equipment before proceeding Procedure 1 Remove Front Panel A Disconnect Batteries El Remove Dispose of Batteries 4 Add Batteries 5 Connect Batteries Attach co
49. moin DEL est rouge allum en continu ou clignotante supprimer imm diatement la surcharge en d branchant une partie de l quipement des sorties jusqu ce que la DEL passe du rouge au jaune ou vert ATTENTION Toute surcharge qui n est pas imm diatement corrig e par l utilisateur peut amener l onduleur se mettre hors tension et cesser de fournir de la puissance de sortie dans le cas d une panne d lectricit ou d une chute de tension du secteur DEL BATTERY CHARGE lorsque l onduleur fonctionne partir du courant du secteur ce t moin DEL indique l tat approximatif de la charge des batteries internes de l onduleur rouge indique que les batteries commencent se charger jaune indique que les batteries sont charg es environ la moiti de leur capacit et vert indique que les batteries sont compl tement charg es Lorsque l onduleur fonction partir de la puissance des batteries durant une panne d lectricit ou une chute de tension importante du secteur ce t moin DEL indique la quantit approximative d nergie affectant en fin de compte le temps d ex cution que les batteries de l onduleur vont fournir rouge indique un faible niveau d nergie jaune indique un niveau moyen d nergie et vert indique un haut niveau d nergie tant donn que la performance d ex cution de toutes les batteries de l onduleur va graduellement s puiser avec le temps il est recommand d effectuer p riodiquement un autote
50. n segundo Suelte el bot n 13 12 130 93328A indb 17 1 6 2014 2 59 34 PM Instalaci n Opcional Estas conexiones son opcionales Su UPS trabajar correctamente sin estas conexiones Fl Comunicaciones USB y Serial RS 232 todos los modelos Use el cable USB incluido ver EX y o cable serial DB9 ver FE para conectar el puerto de comunicaci n en su computadora al puerto de comunicaci n de su UPS Instale en su computadora el Software PowerAlert de Tripp Lite apropiado al sistema operativo de su computadora Su 502025 UPS puede contar con puertos de W Ena w Esp n EB 00 comunicaci n adicionales estos puertos EN IR pueden conectarse tambi n a OD computadoras adicionales que tengan instalado el Software PowerAlert Para m s informaci n consulte su manual de PowerAlert EJ Conexi n del Puerto EPO js e s y ep todos los modelos Mesum 290902002000000000022900 Esta caracteristica opcional es s lo para aquellas aplicaciones que requieran conexi n a un circuito de Apagado de Emergencia EPO de la instalaci n Cuando el UPS est conectado a este circuito habilita el apagado de emergencia del inversor del UPS OPCI N 1 INTERRUPTOR NORMALMENTE CERRADO PROPORCIONADO POR EL USUARIO 45 JUMPER Usando el cable proporcionado conecte el puerto de EPO de su UPS ver ET a un interruptor normalmente cerrado o normalmente abierto proporcionado por el usuario de acuerdo al diagrama del
51. nnectors black to black and red to red r3 Replace Front Panel 11 13 12 130 93328A indb 11 1 6 2014 2 59 24 PM Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See Web site for details FCC RADIO TV INTERFERENCE NOTICE FOR CLASS A MODELS Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC RADIO TV INTERFERENCE NOTICE FOR CLASS B MODELS Note This equipment has been tested and found to comply with
52. onde la falla de este equipo pueda razonablemente causar la falla del equipo de soporte de vida o afectar significativamente su seguridad o efectividad No use este equipo en presencia de una mezcla inflamable de anest sicos con aire ox geno u xido nitroso No conecte supresores de sobretensiones o cables de extensi n a la salida del UPS Esto puede da ar al UPS y afectar las garant as del supresor de sobretensiones y del UPS 14 13 12 130 93328A indb 14 1 6 2014 2 59 27 PM Instrucciones Importantes de Seguridad Advertencias de la Bateria as bater as pueden presentar un riesgo de descarga el ctrica y quemaduras por la alta corriente de corto circuito Observe las precauciones apropiadas No deseche las bater as en un fuego No abra el UPS o las bater as No ponga en corto o puentee las terminales de la bater a con objeto alguno Desenchufe y apague el UPS antes de ejecutar el reemplazo de la bater a Use herramientas con mangos aislados No hay partes dentro del UPS a las que el usuario pueda dar servicio El reemplazo de la bater a debe realizarlo s lo personal de servicio autorizado usando el mismo n mero y tipo de bater as Plomo cido Selladas Las bater as son reciclables Para informaci n sobre el reciclado refi rase a sus c digos locales para los requisitos de desecho o visite www tripplite com UPSbatteryrecycling Tripp Lite ofrece una l nea completa de Cartuchos de Bater a de Repuesto R B C para Sis
53. onduleur Le remplacement de la batterie devrait tre effectu uniquement par le personnel de service autoris en utilisant des batteries du m me type portant le m me num ro batterie au plomb acide scell e Les batteries sont recyclables R f rez vous vos codes locaux pour conna tre les exigences en mati re d limination des batteries ou visitez www tripplite com UPSbatteryrecycling pour plus de renseignements au sujet du recyclage Tripp Lite offre une gamme compl te de cartouches de batterie de remplacement d onduleur Visitez Tripp Lite sur le Web WWW tripplite com support battery index cfm pour trouver la batterie de remplacement sp cifique a votre onduleur Le type de cartouche de batterie de remplacement se trouve galement sur l tiquette appos e la plaque de r tention de la batterie Lors du remplacement chaud de la batterie l onduleur ne fournira pas d alimentation de secours dans l ventualit d une panne de courant ou d autres coupures de courant Ne pas faire fonctionner l onduleur sans batteries e remplacement des batteries devrait tre effectu ou supervis par du personnel comp tent dans le domaine des batteries et en tenant compte des mesures de s curit appropri es Au moment de remplacer les batteries les remplacer avec le m me type et le m me nombre de batteries ou de blocs batteries e MISE EN GARDE Ne pas jeter les batteries dans le feu Les batteries risqueraient d explos
54. oper ventilation Do not obstruct its vents or fan openings e When mounting the UPS system in a tower orientation make sure the LED Screen panel is at the top of the UPS not at the bottom Do not mount unit with its front or rear panel facing down at any angle Mounting in this manner will seriously inhibit the unit s internal cooling eventually causing product damage not covered under warranty UPS Connection Warnings he UPS contains its own energy source battery The output terminals may be live even when the UPS is not connected to an AC supply Connect the UPS to a properly grounded AC power outlet Do not modify the UPS s plug in a way that would eliminate the UPS s connection to ground Do not use adapters that eliminate the UPS s connection to ground Do not plug the UPS into itself this will damage the UPS and void your warranty If you are connecting the UPS to a motor powered AC generator the generator must provide filtered frequency regulated computer grade output Connecting the UPS to a generator will void its Ultimate Lifetime Insurance Equipment Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous
55. rm sounds intermittently after you initiate a self test See MUTE TEST Button description LA to indicate the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED continues to light contact Tripp Lite for service If your UPS requires battery replacement visit www tripplite com to locate the specific Tripp Lite replacement battery for your UPS 13 12 130 93328A indb 8 1 6 2014 2 59 23 PM AC Receptacles Your UPS features 15 amp AC outlets These output receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and brownouts The UPS protects equipment connected to these receptacles against damaging surges and line noise If you have a serial or USB connection to your UPS you can remotely reboot connected equipment by turning the receptacles OFF and ON NEMA 5 15R using Tripp Lite s PowerAlert Software Select models have their receptacles divided into one or more load banks labelled LOAD 1 etc which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment connected to the other outlets Select models feature special outlets clearly labeled on the rear panel which provide surge only not battery backup protection designed for laser printers and other heavy draw devices Select models also feature outlets labelled UNSWITCHED which
56. ropri taire de la trousse d installation pour la proc dure d installation pour les mod les d onduleur 2U E Attacher les oreilles de montage EN aux trous de montage avant de l quipement E en utilisant les vis fournies M Les oreilles devraient faire face vers l arri re 2 Avec l assistance d une autre personne au besoin souler l quipement et le monter au b ti Lattacher en vissant la quincaillerie appropri e EJ travers ses oreilles de montage et dans les rails du b ti 13 12 130 93328A indb 28 1 6 2014 2 59 43 PM Monter tous les mod les d onduleur dans une position en tour verticale en utilisant la quincaillerie incluse L utilisateur doit d terminer l aptitude du mat riel et des proc dures avant le montage Tous les mod les d onduleur Mettre l onduleur sur le c t avec le panneau de commande DEL sur le dessus Attacher une oreille de montage pour b ti EM chaque c t de l onduleur en utilisant les vis fournies El Attacher les oreilles de montage pour b ti au plancher en utilisant de la quincaillerie fournie par l utilisateur Installation rapide Fa Brancher l onduleur dans une prise sur un circuit sp cialis NEMA 5 15P Remarque Une fois branch une prise CA Fiche illustr e sous tension l onduleur en mode Attente commencera automatiquement recharger ses batteries mais n alimentera ses prises qu une fois l interrupteur plac en position ON marche
57. s d brancher l onduleur de la prise murale Si l onduleur est entrepos pour une p riode de temps prolong e recharger les batteries de l onduleur une fois tous les trois mois brancher l onduleur dans une prise murale lui permettre de se charger pendant 12 heures puis le d brancher et le retourner en entreposage Remarque apr s avoir branch l onduleur il va commencer automatiquement charger ses batteries il ne va toutefois pas alimenter ses sorties consulter Installation rapide Si les batteries de l onduleur sont laiss es d charg es pendant une p riode de temps prolong e cela nuira leur capacit de facon permanente Entretien Une vari t de garantie prolong es et de programmes de service sur place sont galement disponibles chez Tripp Lite Pour plus de renseignements sur le service visitez www tripplite com support Avant de retourner votre produit pour entretien ou r paration suivez les tapes suivantes 1 Relisez les directives d installation et de fonctionnement de ce manuel afin de vous assurer que le probl me n a pas pour origine une mauvaise lecture des directives 2 Sile probl me persiste ne pas communiquer ou renvoyer le produit au vendeur la place visitez www tripplite com support 3 Si le probl me n cessite une r paration visitez www tripplite com support et cliquez sur le lien Product Returns retour du produit De cet endroit vous pouvez demander un num ro d autorisation de re
58. st voir la description du bouton MUTE TEST sourdine test afin de d terminer le niveau d nergie des batteries de l onduleur AVANT qu une panne d lectricit ou une chute de tension importante du secteur ne se produise Durant une panne d lectricit prolong e ou une chute de tension importante du secteur il est recommand de sauvegarder les fichiers et de mettre l quipement hors tension tant donn que l alimentation des batteries va ventuellement s puiser Lorsque le t moin DEL passe au rouge et que l alarme se fait entendre en continu cela indique que les batteries de l onduleur sont presque puis es et que la mise hors tension de l onduleur est imminente DEL BATTERY WARNING avertissement de la batterie ce t moin DEL passe au rouge et une alarme se fait entendre de facon intermittente apr s l initiation d un autotest Voir la description du bouton MUTE TEST sourdine test pour indiquer que les batteries de l onduleur ont besoin d tre recharg es ou remplac es Permettre l onduleur de se recharger sans interruption pendant 12 heures et r p ter l autotest Si le t moin DEL demeure allum en continu contacter Tripp Lite pour obtenir du service Si les batteries de l onduleur ont besoin d tre remplac es visiter www tripplite com pour d terminer la batterie de remplacement Tripp Lite sp cifique votre onduleur 32 j MIS S 13 12 130 93328A indb 32 1 6 2014 2 59 45 PM Fonctionnement de b
59. t quipement a t test et trouv conforme aux restrictions applicables un appareil num rique de classe B conform ment la partie 15 des r glements de la FCC Ces restrictions sont concues pour assurer une protection raisonnable contre les interf rences nuisibles quand le mat riel est utilis dans une installation r sidentielle Cet quipement g n re utilise et peut mettre de l nergie radiofr quence et s il n est pas install et utilis en conformit avec le manuel d instruction peut causer des interf rences aux communications radio Cependant il n y a aucune garantie que les interf rences ne se produiront pas dans une installation particuli re Si cet quipement cause des interf rences nuisibles la r ception des signaux de radio ou de t l vision ce qui peut tre d termin en mettant l quipement hors tension et sous tension l utilisateur est encourag tenter de corriger l interface en faisant appel une ou plusieurs des mesures suivantes r orienter ou changer l emplacement de l antenne de r ception augmenter l cart entre l quipement et le r cepteur brancher l quipement dans une prise sur un circuit diff rent de celui auquel le r cepteur est connect consulter le concessionnaire ou un e technicien ne exp riment e en radio t l vision pour obtenir de l aide L utilisateur doit utiliser des c bles et des connecteurs blind s avec ce produit Tout changement ou modification apport e
60. t s allume en continu lorsque l onduleur est sous tension et qu il fournit de la puissance CA l quipement connect partir d une source d alimentation Le t moin DEL clignote et une alarme se fait entendre 4 bips courts suivis d une pause pour indiquer que l onduleur fonctionne partir de ses batteries internes durant une panne d lectricit ou une chute de tension importante du secteur Si la panne d lectricit ou la chute de tension importante du secteur est prolong e il est recommand de sauvegarder les fichiers et de mettre l quipement hors tension tant donn que l alimentation des batteries internes va ventuellement s puiser Voir la description du t moin DEL BATTERY CHARGE charge des batteries ci dessous DEL VOLTAGE CORRECTION correction de la tension ce t moin DEL vert s allume en continu chaque fois que l onduleur corrige automatiquement une haute ou une basse tension CA sur la ligne publique de transport d nergie sans l aide de l alimentation par batteries L onduleur va galement mettre un faible cliquetis Ce sont des op rations automatiques normales de l onduleur aucune mesure n est requise de votre part DEL OUTPUT LOAD LEVEL niveau de charge de sortie ce t moin DEL multicolore indique la charge lectrique approximative de l quipement branch aux sorties de l onduleur Elle va passer du vert faible charge au jaune charge moyenne au rouge surcharge Si le t
61. talaci n de 1U en Rack Sistemas UPS Inteligentes Interactivos Salida de 120V 500VA 1000VA SMART500RT1U SMART750RM1U SMART1000RM1U Serie AG 0097 Serie AGSM8269 Serie AGSM5060 No es adecuado para aplicaciones m viles Instrucciones Importantes de Seguridad 14 Instalaci n 16 Instalaci n R pida 17 Instalaci n Opcional 18 Operaci n B sica 18 Almacenamiento y Servicio 22 Reemplazo de la Bater a 23 Avisos 24 English 1 Francais 25 TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite Todos los derechos reservados SmartPro es una marca registrada Tripp Lite 13 12 130 93328A indb 13 1 6 2014 2 59 26 PM Instrucciones Importantes de Seguridad GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones importantes que deben seguirse durante la instalaci n operaci n y almacenamiento de este producto La omisi n en la observancia de estas advertencias puede afectar la garant a Advertencias de Ubicaci n del UPS Tenga cuidado al levantar el UPS Debido al peso considerable de todos los sistemas UPS para instalaci n en rack deben ayudar al menos dos personas para levantarlos e instalarlos e Instale el UPS en interiores alejado de humedad o calor excesivos polvo o luz solar directa e Para mejor rendimiento la temperatura ambiente en proximidad al UPS debe estar entre 0 C y 40 C entre 32 F y 104
62. temas UPS Para localizar la bater a de repuesto espec fica para su UPS visite Tripp Lite en el sitio www tripplite com support battery index cfm El tipo de RBC puede encontrarse tambi n en la etiqueta fijada en la placa de sujeci n de la bater a Durante el reemplazo de la bater a en funcionamiento el UPS no suministrar energ a de respaldo en caso de un apag n y otras interrupciones de energ a No opere el UPS sin bater as El Servicio a las bater as debe ser ejecutado o supervisado por personal conocedor de bater as y las precauciones requeridas e Al remplazar bater as utilice el mismo tipo y n mero de bater as o m dulos de bater as e PRECAUCI N No deseche las bater as en el fuego Las bater as pueden explotar e PRECAUCI N No abra o mutile las bater as El electrolito liberado es da ino a la piel y ojos Puede ser t xico e PRECAUCI N Una bater a puede presentar un riesgo de descarga el ctrica y quemaduras por corto circuito de alta corriente Al trabajar con bater as deben observarse las siguientes precauciones o Retire relojes anillos u otros objetos met licos o Use herramientas con mangos aislados o Use guantes y botas de hule o No apoye o deje herramientas o partes met licas sobre la parte superior de las bater as o Determine si la bater a est conectada a tierra de forma inadvertida Si est conectada a tierra de forma inadvertida elimine el origen de la conexi n a tierra
63. tions y compris une liste de SNMP produits de gestion de r seau et de connectivit disponibles R glage de la sensibilit de la puissance Ce cadran est normalement enti rement tourn dans le sens des aiguilles d une montre ce qui permet ON l onduleur de fournir une protection maximum contre les distorsions de l onde lectrique dans son entr e CA Lorsqu une telle distortion se produit l onduleur va NORM DELAY normalement commencer fournir de la puissance sinuso dale partir des r serves de ses batteries tant et aussi lontemps que la distorsion est pr sente Dans les endroits o le courant du secteur est de mauvaise qualit ou la puissance d entr e de l onduleur provient d une g n ratrice auxiliaire la distorsion harmonique chronique risque d entra ner l onduleur passer trop fr quemment en mode batterie puisant les r serves de ses batteries ll peut tre possible de r duire la fr quence des passages de l onduleur en mode batterie en raison de la distorsion harmonique mod r e en exp rimentant avec les diff rents r glages du cadran Lorsque le cadran est tourn dans le sens des aiguilles d une montre l onduleur devient plus tol rant aux variations au niveau des formes d onde CA de sa puissance d entr e REMARQUE Plus le cadran est tourn dans le sens des aiguilles d une montre plus l onduleur permettra le passage de distortion harmonique vers l quipement connect En exp rimentant avec les dif
64. todiagn stico puede causar que el UPS se apague y deje de suministrar energ a de salida en caso de un apag n o ca da de voltaje Si el LED de BATTERY WARNING ADVERTENCIA DE BATER A permanece encendido y la alarma contin a sonando despu s de la prueba las bater as del UPS necesitan ser recargadas o reemplazadas Permita al UPS recargar continuamente por 12 horas y repita el autodiagn stico Si el LED permanece encendido solicite servicio a Tripp Lite Si su UPS requiere reemplazo de la bater a visite www tripplite com para localizar la bater a de reemplazo espec fica de Tripp Lite para su UPS La alarma sonar brevemente una vez despu s de transcurrido el intervalo se alado 19 13 12 130 93328A indb 19 1 6 2014 2 59 37 PM Operacion B siCa continuaci n Luces Inicadoras Panel Frontal Todas las descripciones de las Luces Indicadoras se aplican cuando se enchufa el UPS en un tomacorriente de pared y encendido LED POWER este LED verde enciende continuamente cuando el UPS est encendido y suministrando energ a de CA a los equipos conectados desde una fuente de alimentaci n de servicio El LED destella y suena una alarma 4 bips cortos seguidos de una pausa para indicar que el UPS est funcionando desde sus bater as internas durante un apag n o reducci n severa de voltaje Si se prolonga el apag n o reducci n severa de voltaje debe guardar sus archivos y apagar su equipo ya que la energ a d
65. tour de mat riel RMA qui est exig pour une r paration Ce formulaire en ligne simple vous demandera le num ro de mod le et le num ro de s rie de votre unit ainsi que d autres renseignements g n raux concernant l acheteur Le num ro RMA ainsi que les instructions concernant le transport vous seront achemin es par courriel Tout dommage direct indirect sp cial ou fortuit survenu au produit pendant le transport Tripp Lite ou un centre de service autoris Tripp Lite est exclu de la garanti Les produits exp di s Tripp Lite ou un centre de service autoris doivent tre pr pay s Inscrire le num ro RMA sur le paquet Si le produit est encore couvert par la garantie de deux ans joindre une copie de votre facture d achat Retourner le produit pour r paration par un transporteur assur l adresse qui vous a t donn e lorsque vous avez demand le RMA 34 13 12 130 93328A indb 34 1 6 2014 2 59 45 PM Dans des conditions normales les batteries originales de l onduleur dureront plusieurs ann es Consulter la section S curit avant de remplacer les batteries Les batteries sont con ues pour le remplacement chaud c d en laissant l onduleur en mode sous tension mais le personnel d entretien qualifi pourrait d sirer mettre l onduleur en mode hors tension et d brancher l quipement avant de proc der Proc dure 1 Enlever le panneau avant FA D brancher l
66. tructions sur le logiciel pour plus de d tails Ports de communication USB ou RS 232 Ces ports connectent l onduleur n importe quelle station de travail ou serveur Ils doivent tre utilis s avec le logiciel PowerAlert de Tripp Lite et les c bles inclus pour permettre l ordinateur de sauvegarder automatiquement les fichiers ouverts et de mettre l quipement hors tension pendant une panne d lectricit Utiliser galement le logiciel PowerAlert pour surveiller une grande vari t de conditions de fonctionnement de l alimentation CA du secteur et de l onduleur Consulter le manuel du logiciel PowerAlert ou communiquer avec le service la client le de Tripp Lite pour plus de renseignements Consulter la section USB and RS 232 Serial Communications communications s rielles USB et RS 232 pour des directives concernant l installation Port d arr t d urgence EPO l onduleur comporte un port d arr t d urgence EPO qui peut tre utilis pour connecter l onduleur un commutateur de fermeture de contact pour permettre l arr t d urgence de l inverseur Consulter l installation facultative Fente accessoires enlever la petite plaque qui couvre la fente pour installer des accessoires en option pour la surveillance et la gestion distance de l onduleur Se reporter au manuel des accessoires pour des directives d installation Contacter le service la client le de Tripp Lite au 773 869 1234 pour plus d informa