Home
To the Installer - Motorola Solutions
Contents
1. 6 142 379 6 172 478 6 176 428 6 178 426 6 186 400 6 188 681 6 209 788 6 209 789 6 216 951 6 220 514 6 243 447 6 244 513 6 247 647 6 308 061 6 250 551 6 295 031 6 308 061 6 308 892 6 321 990 6 328 213 6 330 244 6 336 587 6 340 114 6 340 115 6 340 119 6 348 773 D305 885 D341 584 D344 501 D359 483 D362 453 D363 700 D363 918 D370 478 D383 124 D391 250 D405 077 D406 581 D414 171 D414 172 D418 500 D419 548 D423 468 D424 035 D430 158 D430 159 D431 562 D436 104 5 912 662 6 011873 6 080 001 6 234 389 6 193 152B1 Invention No 55 358 62 539 69 060 69 187 Taiwan No 1 601 796 1 907 875 1 955 269 Japan European Patent 367 299 414 281 367 300 367 298 UK 2 072 832 France 81 03938 Italy 1 138 713 3 02 Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 htto www symbol com 67923 01 Revision A
2. System Contact System Address Information MAC Address 00 11 22 33 44 55 IP Address 172 16 7 174 Subnet Mask 255 255 0 0 Default Gateway 0000 UAT ta rent 3 10 ES3000 Ethernet Switch Quick Install Guide sk Once the ES3000 user interface has been accessed using either the menu CLI or Web interfaces refer to the ES3000 User Manual for advanced device configuration Note information Go to http Avww symbol com services downloads to access the guide Installing a SFP Fiber Transceiver The ES3000 Ethernet Switch supports a SFP small form factor pluggable fiber channel transceiver used in fiber channel cable installations To install the SFP Fiber Transceiver 1 Remove the rubber plug protecting the optics on the transceiver 2 Insert the transceiver into the fiber transceiver cage available on ports 25 or 26 on the ES3000 Ethernet Switch 3 Ensure one of the following two cable types is used when connecting fiber cable to the ES3000 Ethernet Switch e LC 62 5um 125um multimode fiber optic cable e LC 50um 125um multimode fiber optic cable 4 Consult the system administrator for cable length and installation specifications unique to the installation environement le If removing the SFP transceiver disengage locking mechanism on SFP transceiver ey carefully before removing the transceiver from the ES3000 Ethernet Switch Note Customer Support Symbol Technologies provides its customers with prompt and accurat
3. exposure Radio Frequency Interference Requirements FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Radio Frequency Interference Requirements Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada C Marking and European Economic Area EEA Class A ITE WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Statement of Compliance Symbol Technologies Inc hereby declares that this device is in compliance with all the applicable Directives 89 336 EEC 73 23 EEC A Declaration of Conformity may be obtained from http www2 symbol com doc 14 83000 Ethernet Switch Quick Install Guide Copyright Copyrigh
4. 44 5 142 550 5 149 950 5 157 687 5 168 148 5 168 149 5 180 904 5 216 232 5 229 591 5 230 088 5 235 167 5 243 655 5 247 162 5 250 791 5 250 792 5 260 553 5 262 627 5 262 628 5 266 787 5 278 398 5 280 162 5 280 163 5 280 164 5 280 498 5 304 786 5 304 788 5 306 900 5 324 924 5 337 361 5 367 151 5 373 148 5 378 882 5 396 053 5 396 055 5 399 846 5 408 081 5 410 139 5 410 140 5 412 198 5 418 812 5 420 411 5 436 440 5 444 231 5 449 891 5 449 893 5 468 949 5 471 042 5 478 998 5 479 000 5 479 002 5 479 441 5 504 322 5 519 577 5 528 621 5 532 469 5 543 610 5 545 889 5 552 592 5 557 093 5 578 810 5 581 070 5 589 679 5 589 680 5 608 202 5 612 531 5 619 028 5 627 359 5 637 852 5 664 229 5 668 803 5 675 139 5 693 929 5 698 835 5 705 800 5 714 746 5 723 851 5 734 152 5 734 153 5 742 043 5 745 794 5 754 587 5 762 516 5 763 863 5 767 500 5 789 728 5 789 731 5 808 287 5 811 785 5 811 787 5 815 811 5 821 519 5 821 520 5 823 812 5 828 050 5 848 064 5 850 078 5 861 615 5 874 720 5 875 415 5 900 617 5 902 989 5 907 146 5 912 450 5 914 478 5 917 173 5 920 059 5 923 025 5 929 420 5 945 658 5 945 659 5 946 194 5 959 285 6 002 918 6 021 947 6 029 894 6 031 830 6 036 098 6 047 892 6 050 491 6 053 413 6 056 200 6 065 678 6 067 297 6 082 621 6 084 528 6 088 482 6 092 725 6 101 483 6 102 293 6 104 620 6 114 712 6 115 678 6 119 944 6 123 265 6 131 814 6 138 180
5. Quick Installation Guide a ffl symbol The Fi JA Mobility rprise Mobility Company 2 ES3000 Ethernet Switch Quick Install Guide To the Installer This guide is intended for the technician responsible for installing the Symbol ES3000 Ethernet Switch It is also assumed that the technician is familiar with Ethernet LAN based networking concepts The Symbol ES3000 Ethernet Switch is available in the following models e ES3000 PWR supporting PoE Part Number ES 3000 PWR 10 WW e ES3000 non PoE Part Number ES 3000 10 WW The purpose of this document is to provide specifications features and guidelines for the installer to use during installation This document does not give site specific installation instructions Refer to www symbol com for accessing the ES3000 User Guide for general device configuration information and the ES3000 Advanced Concept Guide for advanced configuration information unique to the ES3000 Document Conventions Before working on any equipment be aware of the hazards associated with its installation and use Also become familiar with standard practices for preventing accidents le Indicates tips hints and special requirements Q Note Care is required Disregarding cautions can cause data loss or equipment damage pe Indicates a potentially dangerous condition or procedure that only Symbol trained DO personnel should attempt to correct or perform Power Cord Set Only use a powe
6. both the PoE and non PoE Ethernet Switch models should contain the following ES3000 Ethernet Switch Quick Installation Guide Rack mounting brackets Power cord optional Null modem serial cable Supplying Power To cable the ES3000 Ethernet Switch to receive power 1 Connect the supplied AC power cord to the power connector on the rear of the Ethernet Switch 2 Plug the cord into a standard AC outlet with a voltage range from 100VAC to 240VAC The Ethernet Switch immediately receives power Administration of the ES3000 Ethernet Switch There are three management user interfaces on the switch menu driven CLI and Web The menu driven and CLI interfaces are accessed using a direct serial connection or via Telnet over an Ethernet connection The Web interface is reached via HTTP over an Ethernet connection to the switch Via direct serial connection yes Via Ethernet connection yes via Telnet yes via Telnet yes via HTML Managing the switch remotely via Telnet or Web requires the switch to have an IP address assigned to it The administrator must know what that IP address is By default the switch is configured to use DHCP to obtain its IP address If the IP address assigned to the switch from the DHCP server can be determined use any of the management interfaces If not access the switch via direct serial connection to determine the IP address assigned via DHCP If a DHCP server is not available on the network access
7. e customer support Use the Symbol Support Center as the primary contact for any technical problem question or support issue involving Symbol products If the Symbol Customer Support specialists cannot solve a problem access to all technical disciplines within Symbol becomes available for further assistance and support Symbol Customer Support responds to calls by email telephone or fax within the time limits set forth in individual contractual agreements When contacting Symbol Customer Support please provide the following information e Serial number of unit e Model number or product name e Software type and version number North American Contacts Inside North America contact Symbol at For sales and product information Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 Telephone 1 631 738 2400 1 800 SCAN 234 Fax 1 631 738 5990 For product support and service Symbol Global Support Center Telephone 1 800 653 5350 1 631 738 6213 Outside North America Fax 631 563 5410 Email supportOsymbol com 12 83000 Ethernet Switch Quick Install Guide International Contacts Outside North America contact Symbol at Symbol Technologies Inc Symbol Place Winnersh Triangle Berkshire RG41 5TP United Kingdom Telephone 0800 328 2424 Inside UK 44 118 945 7529 Outside UK For other sales offices use the Symbol Services Web site for contact information http www symbol com services h
8. oad protection Verify the power connector is accessible at all times during the operation of the equipment Do not work with equipment power circuits in dimly lit spaces Do not install this equipment or work with its power circuits during thunderstorms or weather conditions where power surges can exist Verify adequate ventilation around the device and that ambient temperatures meet equipment operation specifications For plugable equipment the socket outlet shall be installed near the equipment and shall be easily accessible Introduction The Symbol ES3000 Ethernet Switch provides centralized management of network components across the wired network infrastructure The Ethernet Switch connects directly to distributed LAN resources network switch or managed hubs The rack mountable design allows easy installation with other network components The Ethernet Switch provides several features to assist in an efficient system installation e LED Indicators indicate status for power and the condition of the Ethernet ports e Front Mounted Ethernet Ports allows easy access to Ethernet cabling e Serial Console Port allows installers and administrators to connect directly to the device s command line interface CLI Specifications Width 482 6 mm with mounting brackets 440 mm without mounting brackets Height 44 mm 1RU Depth 256 mm Weight PoE version 8 95 lbs with rack brackets PoE version 8 80 Ibs without rack brackets N
9. on PoE version 7 90 Ibs with rack brackets Non PoE version 7 75 Ibs without rack brackets Max Power Consumption 100VAC 240VAC 50Hz 60Hz 3 5A PoE 100VAC 240VAC 50Hz 60Hz 1 5A non PoE Operating Temperature 0 to 40 C Operating Humidity 10 to 85 without condensation MTBF ES 3000 PWR 10 WW 140 000 hours 25 C ES 3000 10 WW 355 000 hours O 25 C FIBER 3000 1S WW 1 250 000 hours 25 C 6 ES3000 Ethernet Switch Quick Install Guide Installation Preparing for Site Installation Site preparation for the ES3000 Ethernet Switch installation begins with a site survey and network analysis Review the site survey reports to determine specific equipment placement site specific port capacity and power drops Ensure the installation area is free of dust and dirt Review the following guidelines for site preparation Assign installation responsibility to appropriate personnel Identify where all installed components are located Verify appropriate rack mounting requirements Arrange for a sufficient number of power drops to support the equipment installation Verify adequate ventilation to all installed equipment Identify and prepare Ethernet and TCP IP and serial port connections Verify cable lengths are within maximum allowable distances for optimal signal transmission Package Contents Inspect the package contents and report any missing or damaged items to the Symbol sales representative The package for
10. owto howto_contact_us html Web Support Sites Comprehensive On line support is available at the MySymbolCare Web site Registration is free and a variety of services can be linked through this web portal MySymbolCare http Awww symbol com services msc Symbol Services Homepage http www symbol com services Symbol Software Updates http Awww symbol com services downloads Symbol Developer Program Web site http devzone symbol com Additional Information Obtain additional information by contacting Symbol at Telephone 1 800 722 6234 Inside North America 1 631 738 5200 Inside Outside North America http www symbol com Regulatory Information All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required Any changes or modifications to Symbol Technologies equipment not expressly approved by Symbol Technologies could void the user s authority to operate the equipment Laser Devices The laser module complies with US 21CFR1040 10 amp 1040 11 and EN60825 1 1994 A11 A2 The laser classification is marked on the SFP Module Class 1 Laser devices are not considered to be hazardous when used for their intended purpose The following statement is required to comply with US and international regulations Caution Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous laser light
11. r cord approved for its intended country of operation U S A and Canada The cord set must be UL approved and CSA certified The minimum specification for the flexible cord is No 18AWG Type SV or SJ 3 conductor The cord set must have a rated current capacity of at least 15A The attachment plug must be an earth grounding type with a NEMA 5 15P 15A 125V or NEMA 6 15P 15A 250V configuration Denmark The supply plug must comply with section 107 2 D1 standard DK2 1a or DK2 5a Switzerland The supply plug must comply with SEV ASE 1011 Others The power cord shall meet local regulation requirement if any The appliance coupler the connector to the unit and not the wall plug must have a configuration for mating with an EN60320 IEC320 appliance inlet 4 ES3000 Ethernet Switch Quick Install Guide Warnings Only trained and qualified personnel are allowed to install this equipment Remove any jewelry rings watches necklaces etc while installing this equipment Install this equipment in racks with appropriate dimensions and weight allowances Verify racks are anchored and do not install in a way that can cause the equipment to tip and break Damage to the device or bodily injury can occur from equipment not appropriately mounted and secured Verify the unit and any device connected to it is properly wired and grounded Attach only approved power cords to the device Verify connecting power circuits have appropriate overl
12. se the ES3000 Web Management interface to configure the device le A network connection is required between the device and the host to use the Web ey Management interface to configure the device Note 1 Access the Web interface using a Web browser by entering the switch IP address into the address bar Press Enter Enter Network Password 21x yo Please type your user name and password Site 17216 7 174 Realm Godhead UserName fo s Password O TT Save this password in your password list ok _ Coca Internet Explorer 5 0 or later or Netscape Navigator 6 0 or later is required 2 Enter a user name of admin and password of symbol Press OK The Web interface General Information page displays 3 Ethernet Switch 3000 Network Management System Microsoft Internet Explorer Ele Edt View Favoes look Help ES 3000 inernet sui D General Info _ System Admin I Ports VLANs L IGMP Snooping Spanning Tree J Qos PARAR AANAAA E o ius esso Y M Y 000000000000 General Information System Up Time Oday s 2hr s 39min s 15sec s Boot Code Version Date 1 0 0 6 Feb 13 2004 11 34 49 Runtime Code Version Date 1 0 402 Feb 16 2004 18 47 16 Hardware Information Revision H WWersion1 POE DRAM Size 32MB Flash Size 8MB Console Baud Rate 19200 bps Administration Information System Name System Location
13. t c 2004 by Symbol Technologies Inc All rights reserved No part of this publication can be modified or adapted in any way for any purposes without permission in writing from Symbol The material in this manual is subject to change without notice Symbol reserves the right to make changes to any product to improve reliability function or design No license is granted either expressly or by implication estoppel or otherwise under any Symbol Technologies Inc intellectual property rights An implied license only exists for equipment circuits and subsystems contained in Symbol products Symbol the Symbol logo are registered trademarks of Symbol Technologies Inc Other product names mentioned in this manual can be trademarks or registered trademarks of their respective companies and are hereby acknowledged IBM is a registered trademark of International Business Machine Corporation Microsoft Windows and Windows NT are registered trademarks of Microsoft Corporation Novell and LAN Workplace are registered trademarks of Novell Inc Toshiba is a trademark of Toshiba Corporation Patents This product is covered by one or more of the following U S and foreign Patents 4 593 186 4 603 262 4 607 156 4 652 750 4 673 805 4 736 095 4 758 717 4 760 248 4 806 742 4 816 660 4 845 350 4 896 026 4 897 532 4 923 281 4 933 538 4 992 717 5 015 833 5 017 765 5 021 641 5 029 183 5 047 617 5 103 461 5 113 445 5 130 520 5 140 1
14. the switch via direct serial connection to assign an IP address to the switch To configure or determine the IP address on the switch via direct serial connection 1 Use Hyperterminal or other communications utility to secure a connection to the ES3000 Ethernet Switch 2 Configure the terminal emulation application and operating system to support the following serial port specifications Terminal Type VT 100 Bits per second 19200 Data bits 8 8 ES3000 Ethernet Switch Quick Install Guide Parity None Stop bits 1 Flow control None Hit the return key lt Enter gt to display the ES3000 logon screen Enter a user name of admin and password of symbol Press Enter Select System Admin from the main menu Press Enter Select Access from the System Admin menu Press Enter Select IP Config from the Access menu Press Enter 93 01 09 The System IP Configuration Menu displays F Hyper Terminal HyperTerminal olx File Edit View Call Transfer Help Ole als ajaj si ES3000 Local Management System Access gt System IP Configuration Menu MAC Address 00 13 24 36 46 13 IP Address 0 0 0 0 Subnet Mask 0 0 Default Gateway 0 0 0 0 Mode Enabled Set I P Address Set Subnet Mlask Set Default Glateway Set DIHCP Status Qluit to previous menu Command gt Enter the character in square brackets to select option Connected 0 37 02 VT100 182008N SCROLL CAPS NUM Capture Print echo 4 To u
Download Pdf Manuals
Related Search
Related Contents
FICHE PRODUIT MEGUIAR`S G18216 CIRE ULTIMATE WAX AgentCOM User Manual Philips 6885XL Electric Shaver User Manual Arat NS1574.2 holder Weider PRO 6900 SYSTEM 14922 User's Manual technical manual Certificat de Qualification Professionnelle Assistant(e) commercial(e Gorenje NRK6192JBK fridge-freezer Copyright © All rights reserved.
Failed to retrieve file