Home
SUPERSERVER 7047R-TRF
Contents
1. HURAE AIRES EA ARIE IEA FE EE ARD TASTE TER EDS Chapter 4 Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne la remplacer que par une pile de type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant jAdvertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bater a exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las bater as gastadas seg n las instrucciones del fabricante Lm rona v nrpn T1123 maa noon Pw ys nip FIR MAND Dip 203 792107 NN Ten MINIT 99 v mumunn 12210 0 pY o Ai dl Alls 8 Ge jai lUa AUS Sagi iriall AS All Cine d US Lats Le sl p sill Gadi 1558 2 4S pil Slade li Sty Ua peal AI SHEA AJA SOA xuwe 990 geuu 7s aA Ata SS FRA MAJE wA suu AZAS AAA uber Aa aE Ale S
2. yo Jai casa J s ca So AN 5 d al SS alal Sall dl Ja 9 da NAW x SAU sep AMAL deren dier e TEA ue xeu AAAS BE Ads AEE wear au Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen 4 7 SUPERSERVER 7047R TRF USER S MANUAL Equipment Installation A Warning Only trained and qualified personnel should be allowed to install replace or service this equipment BLL F RI BEEN AUNT ORO it EE EA Ze EY ENTOES BER AE BURSA BEET EL aE SE n TEE BEBE IS SS Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden iAdvertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s rg Way Dsg nn 1 TPE DN Ton PPAT RWI 72353 15015 nm Steal Lead au pally Sall gall Jai eas oj Gay Sas wu xeu ER 389 Wa HE
3. Chapter 2 Server Installation 2 1 Overview This chapter provides a quick setup checklist to get your SuperServer 7047R TRF up and running Following these steps in the order given should enable you to have the system operational within a minimum amount of time This quick setup assumes that your system has come to you with the processors and memory preinstalled If your system is not already fully integrated with a serverboard processors system memory etc please turn to the chapter or section noted in each step for details on installing specific components The SuperServer 7047R TRF may be employed either as a tower or mounted in a rack as a 4U rackmount chassis If using it as a tower unit please read the Server Precautions in the next section and then skip ahead to Section 2 5 2 2 Unpacking the System You should inspect the box the system was shipped in and note if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the SuperServer 7047R TRF It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the system was shipped in may include two sets of rail assembl
4. Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stob Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control This feature allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal
5. SUPERSERVER 7047R TRF USER S MANUAL Installation Instructions A Warning Read the installation instructions before connecting the system to the power source VAT LEEW I FM eS yx REL ET gt EE BEC ESSE ZE Beart Warnung lesen Vor dem AnschlieRen des Systems an die Stromquelle die Installationsanweisungen jAdvertencia alimentaci n Lea las instrucciones de instalaci n antes de conectar el sistema a la red de Attention d installation Avant de brancher le syst me sur la source d alimentation consulter les directives nna npa Tn 199 UI DININI nx Rp v JAMS dado del dap MUS Waarschuwing aansluit Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron 4 4 Chapter 4 Warning Statements for AC Systems Circuit Breaker A Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A t Ay AE E TO TS BER GAED PRES LD SE CO RIMMEL UC x3 TREE TO ERK D 250 V 20 AZe A 7g CE AMEE PEW EP Su Rd E Cabs it GRP EB EP HEE ORR Ce p m PIE IRRKF250V 20A ea Fit PR FH SR IY CR Bat he ie DR ER SE
6. SUPER SUPERSERVER 7047R TRF oo000000 oo0000000 O0000000 0000000 D D USER S MANUAL Revision 1 0b The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in this manual at any time and without notice This product including software and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SU
7. This item displays the period of time during which long duration power is maintained Recommended Short Duration Power This item displays the short duration power settings recommended by the manufacturer Short Duration Power Limit This item displays the period of time during which short duration power is maintained 7 7 SUPERSERVER 7047R TRF USER S MANUAL gt Chipset Configuration gt North Bridge This feature allows the user to configure the settings for the Intel North Bridge IO Hub Configuration Intel VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual Working Memory through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enabled and Disabled Intel I OAT The Intel I OAT I O Acceleration Technolgy significantly reduces CPU overhead by leveraging CPU architectural improvements freeing the system resource for other tasks The options are Disabled and Enabled DCA Support Select Enabled to use Intel s DCA Direct Cache Access Technolgy to improve data transfer efficiency The options are Enabled and Disabled IOH 0 PCle Port Bifurcation Control This submenu allows the user to configure the following 8 PCle Port Bifurcation Control se
8. Disabled IDE Mode AHCI Mode and RAID Mode The following are displayed depending on your selection IDE Mode The following items are displayed when IDE Mode is selected Serial ATA SATA Controller 0 1 Use this feature to activate or dactivate the SATA controller and set the compatibility mode The options for Controller 0 are Enhanced and Compatible The default setting for SATA Controller 1 is Enhanced AHCI Mode The following items are displayed when the AHCI Mode is selected Aggressive Link Power Management Select Enabled to enable Aggressive Link Power Management to support Cougar Point BO stepping and beyond The options are Enabled and Disabled 7 14 Chapter 7 BIOS Port 0 Port 5 Hot Plug Select Enabled to enable hot plug support for a port specified by the user so that the user is allowed to change a hardware component or a device without shutting down the system The options are Enabled and Disabled Staggered Spin up Select Enabled to enable Staggered Spin up support to prevent excessive power consumption caused by multiple HDDs spinning up simultaneously The options are Enabled and Disabled RAID Mode The following items are displayed when RAID Mode is selected PCH RAID CodeBase Set this item to Intel or LSI to specify the codebase to be used for RAID support The options are Intel and LSI Port 0 5 Hot Plug Select Enabled to enable hot plug support for a port specified by the user The opt
9. ME Management Engine Subsystem Intel ME Subsystem Configuration This feature displays the following ME Subsystem Configuration settings ME Subsystem Select Enabled to support Intel Management Engine ME Subsystem a small power computer subsystem that performs various tasks in the background The options are Enabled and Disabled When ME Subsystem is enabled the following items will display ME BIOS Interface ME Version To set this feature select Load Fail Safe Defaults from the Exit menu and press Enter The Fail Safe settings are designed for maximum system stability but not maximum performance 7 4 Event Logs Change SmBIOS Event Log Settings Enabling Disabling Options Smbios Event Log Change this item to enable or disable all features of the Smbios Event Logging during boot The options are Enabled and Disabled Erasing Settings Erase Event Log This option erases all logged events The options are No Yes Next reset and Yes Every reset When Log is Full This option automatically clears the Event Log memory of all messages when it is full The options are Do Nothing and Erase Immediately Smbios Event Log Standard Settings 7 22 Chapter 7 BIOS Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled The options are Disabled and Enabled MECI The Multiple Event Count Increment MECI counter counts the number of occurences a duplica
10. Overloadirig iuter etai o iei ce pue 2 3 Reliable Ground eec 2 4 Installing the System into a Rack Identifying the Sections of the Rack 2 4 Installirig the Chassis Ralils eiecit Een rettet Peas 2 6 Installirig the Rack Rails tite tree er aen there ed 2 7 vi Table of Contents Installing the Server into the Rack citet perire 2 8 2 6 Checking the Serverboard 2 9 2 7 Checking the Drive Bay Setup eee eB iege 2 10 Chapter 3 System Interface 3 1 OVENI WW oneri eege ee een Een 3 1 3 2 Gontrol Panel B ttOns oreet rr rire eene ren 3 1 POW Sire tia ei eie eee ido ea use daba 3 1 CI M 3 1 E WEE uge EE 3 2 Ower eege 3 2 QI EE 3 2 3 2 3 2 Information RE 3 3 ele E RE 3 3 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning OTM OM aes 4 1 Installation Iristr ctioris nni i rrr rrr rr t Ps 4 4 Circuit E 4 5 Power Disconnection Warhihg eee Ete 4 6 Se eu we NEE 4 8 e EE 4 9 Battery 4 10 Redundant Power Supplies rrr certc Irt td C dieta 4 12 Backplane
11. PAE E TA ATS 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw Uberstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt jAdvertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installation lectrique du local V rifiez que le courant nominal du dispositif de protection n est pas sup rieur 250 V 20 A xm v Ow xp ny 31352 nipnian Aan Oy n 0x12 250 V 20 0 in YAWN IPT 197 En 4 5 SUPERSERVER 7047R TRF USER S MANUAL al jl gall Mel clase cole D all 20 250V e Gal 38 91 Seal andi asl o A duds team sae dad Aes ZAA AAC WEA 250VCEE 20A GESI9D CR m onm 5 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Power Disconnection Warning Warning The system must be disconnected from all sources of power and the pow
12. TPMT 4 12 Chapter 4 Warning Statements for AC Systems aloo las gs 5 Leah lag oj Ss 48 els w ll Ce baa all C 541 4als 1 Gay AI 1 JANE 8 daa F BALA ade AA AAE PAT Waarschuwing Deze eenheid kan meer dan n stroomtoevoeraansluiting bevatten Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken Backplane Voltage A Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing WIT Or LOADS IER I SITL ENED DO TWEETS SEES AEETIS E gt A Ruy i RETE EITS LAERA ERR EE Warnung Wenn das System in Betrieb ist treten auf der RUckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung iAdvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise 4 13 SUPERSERVER 7047R TRF USER S MANUAL Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenance nan 51523 nno LITTIN baaa 3nrn v nyan yen 012 nR
13. Address The options are Enabled and Disabled PERR Generation Select Enabled to allow a device to generate PERR number for a Bus Signal Error Event The options are Enabled and Disabled SERR Generation Select Enabled to allow a device to generate a SERR number for a Bus Signal Error Event The options are Enabled and Disabled Maximum Payload This feature selects the setting for the PCIE maximum payload size The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes Maximum Read Request This feature selects the setting for the PCIE maximum Read Request size The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes 7 16 Chapter 7 BIOS ASPM Support This feature allows the user to set the Active State Power Management ASPM level for a PCI E device Select Force LO to force all PCI E links to operate at LO state Select Auto to allow the system BIOS to automatically set the ASPM level for the system Select Disabled to disable ASPM support The options are Disabled Auto and Force LOs Onboard LAN Option ROM Select This feature selects whether to load the iSCSI or PXE onboard LAN option ROM The options are iSCSI and PXE Load Onboard LAN1 Option ROM Load Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 Option ROM LAN4 Option ROM This is to boot the computer using a network device The default setting
14. Delete gt key is used to invoke the BIOS setup screen There are a few cases when other keys are used such as lt F1 gt lt F2 gt etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note that BIOS has default text messages built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values indicates a submenu Highlighting such an item and pressing the Enter key will open the list of settings within that submenu The BIOS setup utility uses a key based navigation system called hot keys Most of these hot keys lt F1 gt lt F10 gt Enter lt ESC gt Arrow keys etc can be used at any time during the setup navigation process 7 1 SUPERSERVER 7047R TRF USER S MANUAL 7 2 Main Menu When you first enter AMI BIOS Setup Utility you will see the Main Menu screen You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys The Main Menu screen provides you with a system overview which includes the version built date and
15. ID of the AMIBIOS the type speed and number of the processors in the system and the amount of memory installed in the system System Time System Date You can edit this field to change the system time and date Highlight System Time or System Date using the lt Arrow gt keys Enter new values through the keyboard Press the lt Tab gt key or the lt Arrow gt keys to move between fields The date must be entered in DAY MM DD YYYY format The time is entered in HH MM SS format Please note that time is in a 24 hour format For example 5 30 A M appears as 05 30 00 and 5 30 P M as 17 30 00 7 3 Advanced Settings Menu Use the arrow keys to select Advanced and press lt Enter gt to access the following submenu items gt Boot Feature Quiet Boot Set this value to allow the bootup screen options to be modified between POST messages or the OEM logo Select Disabled to allow the computer system to display the POST messages Select Enabled to allow the computer system to display the OEM logo The default setting is Enabled AddOn ROM Display Mode This sets the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Select Force BIOS to use the Option ROM display mode set by the system BIOS The options are Force BIOS and Keep Current Bootup Num Lock Use this feature to set the Power on state for the Numlock key The options are Off and On Wait For F1 If Error 7 2 Chapter 7 BIO
16. Note After making changes on a setting be sure to reboot the system for the changes to take effect gt BMC Network Configuration LAN Channel 1 This feature allows the user to configure the settings for LAN Channel 1 Update IPMI LAN Configuration This feature allows the user to decide if the BIOS should configure the IPMI setting at next system boot The options are No and Yes If the option is set to Yes the user is allowed to configure the IPMI settings at next system boot Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If Unspecified is selected the BIOS will search the next available IP address for this computer without modifying BMC network parameters The options are Static and DHCP Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form e 192 168 10 253 Subnet Mask This item displays the sub network that this computer belongs to The value of each three digit number separated by dots should not exceed 255 Station MAC Address This item displays the Station Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers 7 24 Chapter 7 BIOS Router IP Address This item displays the Router IP address for this computer This
17. P Serial Port Console Redirection These submenus allow the user to configure the following Console Redirection settings for a COM Port 0 or COM Port 1 as specified by the user COM 0 COM 1 Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection The options are Enabled and Disabled The default setting for COMO is Disabled and for COM1 is Enabled P Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Selet VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 7 18 Chapter 7 BIOS Bits Per Second This item sets the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Bits
18. Pins 1 2 Normal Default Pins 2 3 Write Protect Enabled Chapter 5 Advanced Serverboard Setup Manufacturer Mode Select ME Mode Select Jumper Settings JPME1 Jumper Setting Definition Close this jumper JPME1 to bypass SPI flash security and force the system to use the Manufacturer mode which 095 the will allow the user to flash the system Pins 2 3 Manufacture Mode firmware from a host server to modify system settings See the table on the right for jumper settings 5 10 Onboard Indicators GLAN LEDs GLAN LED Link Speed Activity There are two LAN ports LAN1 2 on the motherboard Each Ethernet LAN port has two LEDs The Yellow LED on the right indicates connection and GLAN Activity Indicator activity The Link LED on the left side Right LED Settings Shige Color Status Definition may be green amber or off to indicate the speed of the connection See the tables at right for more information Yellow Off No Connections Flashing Active LAN Connection Speed Indicator Left LED Settings LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz IPMI Dedicated LAN LEDs IPMI LAN In addition to LAN Ports 1 2 an CIE E Dedicated LAN is also located on the I O Backplane The amber LED on the right indicates connection IPMI LAN Link Speed LED Left amp Activity LED Right and act
19. antistatic bags when not in use Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static protected 5 1 SUPERSERVER 7047R TRF USER S MANUAL 5 2 Processor and Heatsink Installation Warning When handling the processor package avoid placing direct pressure on the label area Warning Always connect the power cord last and always remove it before adding removing or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink Important If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Warning Make sure to install the system board into the chassis before you install the CPU heatsink Warning When receiving a server board without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to the Supermicro website for updates on CPU support and memory options Installing the LGA2011 Processor 1 There are two load levers on the LGA2011 socket To open the socket cover first press and release the load lever labeled Open 1st ess down on Load Lever labeled Open 1st 5 2 Chapter 5 Advanced Serverboard Setup 2 Press the second load lever labeled Close 1st to release the lo
20. changes you ve made so far Restore Defaults Select this feature and press lt Enter gt to load the default settings that help optimize system performance When the dialog box appears asking you if you want to load the defaults click Yes to load the default settings or click No to abandon defaults Save As User Defaults Select this feature and press lt Enter gt to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to save the current values as user s default settings or click No to keep the defaults previously saved as the user s defaults 7 26 Chapter 7 BIOS Restore User Defaults Select this feature and press lt Enter gt to load the user s defaults previously saved in the system When the dialog box appears asking you if you want to restore user s defaults click Yes to restore the user s defaults previously saved in the system or click No to abandon the user s defaults that were previously saved Boot Override This feature allows the user to enter a new setting to overwrite the original setting that was saved for the following devices e IBA GE Slot 0400 v1376 UEFI Built in EFI Shell PO ST91000640NS 7 27 SUPERSERVER 7047R TRF USER S MANUAL Notes 7 28 Appendix A BIOS POST Error Codes Appendix A BIOS POST Error Codes During the POST Power On Self Test routines which are performed eac
21. coded I O ports on the X9DRi F include two COM ports one header and one port a VGA monitor port eleven USB 2 0 ports 4x rear 6x header 1x Type A two gigabit Ethernet ports and one dedicated IPMI LAN port Note 1 For more information on IPMI configuration please refer to the IPMI User s Guide posted on our website at http www supermicro com support manuals Graphics Controller The X9DRi F features an integrated Nuvoton WP450R BMC Base board Controller BMC chip which also acts as a video controller 1 2 Chapter 1 Introduction Other Features Other onboard features that promote system health include onboard voltage monitors auto switching voltage regulators chassis and CPU overheat sensors power management AC power loss recovery virus protection and BIOS rescue 1 3 Server Chassis Features The following is a general outline of the main features of the SC745TQ R920B server chassis System Power The SC745TQ R920B features dual redundant 920 Watt power supply Power must be removed from the server before replacing a failed power supply unless a second optional 920 Watt power module is installed to provide the system with redundant power Front Control Panel The control panel on the SuperServer 7047R TRF provides you with system monitoring and control LEDs indicate system power HDD activity network activity system overheat and power supply failure A main power button and a system reset button are
22. on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely into the rack you should hear the locking tabs click Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack see Figure 2 4 Figure 2 4 Installing the Server into a Rack L Note The figure above is for illustrative purposes only Always install servers to the bottom of the rack first 2 8 Chapter 2 Server Installation 2 6 Checking the Serverboard Setup After setting up the the system you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made Accessing the Inside of the System 1 2 If rack mounted first release the screws that secure the unit to the rack Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click There are two screws that secure the cover to the chassis remove these first Locate the latch on the top side if tower of the chassis depress where it says push then lift the latch to release the cover Lift the cover from the chassis to gain full access to the inside of the server See Figure 2 5 Checking the Components and Setup 1 You may have one or two processors already installed into the serverboard Each processor should have its ow
23. questions or experience difficulty contact Supermicro s Technical Support department for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be found on our web site at http Awww supermicro com about policies safety_information cfm Warning Definition A Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents PET OE Fe COMTI Af 397 ure dn 503 3 0C vd C 6 3 SES jr TUS fic TE CT XS PEW ERPS AE BY RE SZ BU SAY LPG ECE TLE IRA FAVA BI ELA FPR SRT LL E EE BEHS ERE EES e ARTE aT OT RE SAS uT RS Gr IR rer TERE Ea ZA EIER gt XE A SEAR TT RE LTETEFE n IERI eme SEE UH ATE H EH t zA S H SUPERSERVER 7047R TRF USER S MANUAL Warnung WICHTIGE SICHERHEITSHINWEISE Di
24. support PCI expansion cards in the system The RSC R2UU UA3E8 riser card can support one card and three full height full length PCI Express x8 expansion cards Installing a PCI Add on Card 1 Remove the chassis cover 2 Release the locking tab that corresponds to the PCI slot shield for the slot you wish to populate 3 Insert the expansion card into the riser card pushing down with your thumbs evenly on both sides of the card 4 Slide the add on card into the riser card and attach the add on card bracket in place of the PCI slot shield 5 Secure the add on card by closing the PCI slot shield lever 6 Connect cables to the add on card as necessary Note If the left side riser is with 2 or more x8 PCI E slots make sure an installed card on the left side riser is detected If it is not then go to the system s BIOS Setup and in Advanced PCI PnP Configuration SXB1 Configuration BIOS setting select the 2x8 option Then save the BIOS setting changes and reboot the system 5 12 Chapter 5 Advanced Serverboard Setup 5 7 Serverboard Details Figure 5 4 X9DRi F Serverboard Layout not drawn to scale wel LAND 15823 usan COM iua ae EH EN ep Si E oooom 2095 20000 lo D KBMAEB oo oo g LAN _ B B s m s B S 5 n n E E d 5 BB s als J
25. wriggling the heatsink 3 Once the CPU is loosened remove the CPU from the CPU socket 4 Remove the used thermal grease and clean the surface of the CPU and the heatsink Reapply the proper amount of thermal grease on the surface before reinstalling the CPU and the heatsink Installing the Heatsinks We recommend the use of active type heatsinks except for 1U systems Use any onboard fan header for the CPU s heatsink fan To install the heatsink please follow the installation instructions that are included with your heatsink package Note Make sure the heatsink is placed so that the fins of the heatsink are in the direction of the airflow in your system Loosen screws in sequence as shown Screw 1 Screw 4 Screw 2 SUPERSERVER 7047R TRF USER S MANUAL 5 3 Connecting Cables Now that the processors are installed the next step is to connect the cables to the serverboard These include the data ribbon cables for the peripherals and control panel and the power cables Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back If you need to disconnect any of these cables you should take care to reroute them as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations If you are configurin
26. 20 Chapter 5 Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X9DRi F serverboard connect the data and power cables and install add on cards All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently 5 1 Handling the Serverboard Static electrical discharge can damage electronic components To prevent damage to printed circuit boards it is important to handle them very carefully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from static discharge Precautions e Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their
27. AIRE 8 amp 5 2 E 00000000 ol E econ ean GZ us e Aerea Ki SUPERO X9DR F 3 Bess t EN E 2 TY E Ke Loo EZ ER 3 pA H SES 602 2238 1 82s salsas Bee Jol 9 g g g slol gl Zieler 5 5 82138 8 8 8 8 PIA E Cg 3 SE SE E 853 4 90 T NC H Re Hid Notes e See Chapter 2 for detailed information on jumpers I O ports and JF1 front panel connections e indicates the location of Pin 1 Jumpers LED Indicators not indicated are for testing only Use only the correct type of onboard CMOS battery as specified by the manufacturer Do not install the onboard battery upside down to avoid possible explosion SUPERSERVER 7047R TRF USER S MANUAL X9DRi F Quick Reference Jumper Description Default Setting JBT1 CMOS Clear See Section 2 7 JPB1 BMC Enabled Pins 1 2 Enabled JPG1 VGA Enabled Pins 1 2 Enabled JPL1 GLAN1 GLAN2 Enable Pins 1 2 Enabled JPME1 Manufacture Mode Pins 1 2 Normal JWD Watch Dog Timer Enable Pins 1 2 Reset JWP1 Write Protect Enable Pins 1 2 Normal LED Descri
28. ANAS 899 gau 4 8 Chapter 4 Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geinstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area A Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations TAA RIEL RS Dt ARIS ML RIES TERME ZZ Ath ML ERI BEE GENT TOMO 2070 F BENNY TO 24M A OZ WfBECS OF ARTE E LASER RIVE AAAS AAEM ELA EE SE TT im E HEERE EER BEC ee A o c ELITR EENE RLE 2 Warnung Diese Einheit ist zur Installation in Bereichen mit beschranktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich iAdvertencia Esta unidad ha sido disefiada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet
29. CH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cell
30. E YTOR VE VDE RUT US nl FETED D BEO COMODO RISES FEW ea 4 16 Chapter 4 Warning Statements for AC Systems Tr SEN ALAS ER USE gt Us FREER NOTERNE CLAS IR LEE BUTT AE iere RRR Pit KGET ec Warnung Die L fter drehen sich U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenstande von den ffnungen des L ftergeh uses entfernt jAdvertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du ch ssis Prenez garde ce que doigts tournevis et autres objets soient loign s du logement du bloc ventilateur INN V OTD PTY ONT JIN TINA WNT pon O07 UND VAT TINA Nw 907 myaxwn klick pn 20 Baal ye day pall AES A 5 sie gat JUS Y all Saal s coe ll casi As 8 yall ALS e las Lt la e y 3 1 AYA a zum 919 9 7p e SA BE xxi 2 spass VS 4 FUG elg S71 ub Aapee GE mapu x
31. Ethernet ports LAN1 ESN TS LAN2 are located on the I O backplane Pine Kee the motherboard In addition 10 SEND IPMI_Dedicated LAN is located above 2 TDO 11 Act LED USB 0 1 ports on the backplane to 3 TDO 12 P3V3SB provide KVM support for IPMI 2 0 All 4 TD1 13 Link 100 LED these ports accept RJ45 type cables EE Please refer to the LED Indicator Section for LAN LED information G Ru 14 Link 1000 LED Yellow 3V3SB 6 TD2 15 Ground T TD2 16 Ground 8 TD3 17 Ground 9 TD3 18 Ground NC No Connection 5 18 Universal Serial Bus USB Four Universal Serial Bus ports USB 0 1 USB 2 3 are located on the I O back panel In addition three USB headers located close to the IO Hub provides six front accessible USB connections USB 4 5 USB 8 9 USB 10 11 One Type A connector USB6 also supports front panel USB connection Cables are not included See the tables on the right for pin definitions Fan Headers This motherboard has eight system CPU fan headers Fan 1 Fan 6 Fan A Fan B on the motherboard All these 4 pin fans headers are backward compatible with the traditional 3 pin fans However fan speed control is available for 4 pin fans only The fan speeds are controlled by Thermal Management via Hardware Monitoring in the Advanced Setting in the BIOS See Chapter 4 for more details See the table on the right for pin definit
32. Information LED Status Description Continously on and red An overheat ocondition has occured This may be caused by cable congestion Blinking red 1 Hz Fan failure check for an inoperative fan Blinking red 0 25 Hz Power failure check for an inoperative power supply Solid blue Local UID has been activated Use this function to locate the server in a rack environment Blinking blue 300 msec Remote UID has been activated Use this function to locate the server from a remote location 3 4 Drive Carrier LEDs Green Each hard drive carrier has a green LED When illuminated this green LED on the front of the hard drive carrier indicates drive activity A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed Please refer to Chapter 6 for instructions on replacing failed hard drives Red The red LED to indicates a hard drive failure If one of the hard drives fail you should be notified by your system management software Please refer to Chapter 6 for instructions on replacing failed hard drives SUPERSERVER 7047R TRF USER S MANUAL Notes 3 4 Chapter 4 Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements The following statements are industry standard warnings provided to warn the user of situations which have the potential for bodily injury Should you have
33. Installation This chapter describes the steps necessary to install the SuperServer 7047R TRF into a rack and check out the server configuration prior to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system Chapter 4 System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 7047R TRF Chapter 5 Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRi F serverboard including the locations and functions of connections headers and jumpers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard SUPERSERVER 7047R TRF USER S MANUAL Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC745TQ R920B server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SAS SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes a
34. Ms P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 2 CPUs amp CPU1 CPU2 8 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 2 CPUs A CPU1 CPU2 10 16 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 Any memory pairs in P1 P2 DIMM slots 2 CPUs amp CPU1 CPU2 16 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 P1 A2 P1 B2 P1 C2 P1 D2 P2 E2 P2 F2 P2 G2 P2 H2 DIMM Module Population Configuration For memory to work properly follow the tables below for memory installation RDIMM Support POR on the E5 2600 Series Processor Platform DIMM DIMMs RDIMM Type POR Speeds in MHz Ranks per DIMM Slots per Populated RDIMM Reg Any Channel per DDR Registered Combination Channel 1 1 Reg ECC DDR3 800 1066 1333 1600 1866 SR DR or QR 2 1 Reg ECC DDR3 800 1066 1333 1600 SR DR or QR 2 2 Reg ECC DDR3 800 1066 1333 1600 Mixing SR DR QR Population Rules 1 Any combination of x4 and x8 RDIMMs with 1 Gb or 2 Gb DRAM Density are supported 2 Populate DIMMs starting with DIMM A1 3 When mixing QR with SR or DR on the same DDR channel put the QR in DIMMAT first Note For the memory modules to work properly please install DIMM modules in pairs with an even number of DIMMs installed Note All channels in a system will run at the fastest common frequency 5 11 SUPERSERVER 7047R TRF USER S MANUAL 5 6 Adding PCI Expansion Cards PCI Expansion Slots One riser card is used to
35. NS to enable PCI Exp Generation 3 support for Port 2A The options are GEN1 GEN2 and GEN3 IOUS PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU3 and PCle port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 3A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3A Select GEN2 to enable PCI Exp Generation 2 support for Port 3A Select GENS to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GEN3 gt QOPI Configuration Current QPI Link This item displays the current status of the QPI Link Current QPI Frequency This item displays the current frequency of the QPI Link QPI Quick Path Interconnect Link Speed Mode Use this feature to select data transfer speed for QPI Link connections The options are Fast and Slow 7 10 Chapter 7 BIOS Link Frequency Select Use this feature to select the desired frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s gt DIMM Configuration Total Memory This item displays the total memory size available in the System Current Memory Mode This item displays the current memory mode Current Memory Speed This item displays the current memory speed Mirroring This item displays if memory mirroring is supported by the motherboard Sparing This item displays if memory sparing can be supported by the motherboard gt DIMM Infor
36. S Select Enabled force the system to wait until the F1 key is pressed when an error occurs The options are Disabled and Enabled Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Enabled the ROM BIOS of the host adaptors will capture Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Disabled the ROM BIOS of the host adaptors will not capture Interrupt 19 and the drives attached to these adaptors will not function as bootable devices The options are Enabled and Disabled Power Configuration Power Button Function If this feature is set to Instant Off the system will power off immediately as soon as the user presses the power button Select 4 Second Override for the system to power off when the user presses the power button for 4 seconds or longer The options are Instant Off and 4 Seconds Override Restore on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last state before a power loss The options are Power On Stay Off and Last State 7 3 SUPERSERVER 7047R TRF USER S MANUAL P CPU Configuration This submenu displays the information o
37. SATA Drives 1 To remove a carrier first open the front bezel 2 Push the release button located beside the drive LEDs See Figure 6 5 3 Swing the handle fully out and then use it to pull the unit straight out Note Your operating system must have RAID support to enable the hot swap capability of the drives Mounting a SATA Drive in a Drive Carrier 1 Insert the drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 2 Secure the drive to the carrier with four screws see Figure 6 6 6 6 Chapter 6 Advanced Chassis Setup Figure 6 5 Removing a Drive Carrier Figure 6 6 Mounting a Drive in a Carrier Pd Se SATA Backplane The SAS SATA drives plug into a backplane Installing Components in the 5 25 Drive Bays The SuperServer 7047R TRF has two 5 25 drive bays Optional DVD ROM drives can be installed into these 5 25 drive bays 1 First power down the system and then remove the top left chassis cover to access the drive components 2 With the cover off remove the two or four screws that secure the drive carrier to the chassis one side only then push the entire empty drive carrier out from the back Adding an Optional DVD ROM Drive 1 Remove the guide plates one on each side from the empty drive carrier and screw them into both sides of the DVD ROM drive using the holes provided 2 Slide the DVD ROM into
38. T Lenger CAE Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen Ger te als Produkte von Supermicro nur bezeichnet gezeigt haben 4 18 Chapter 4 Warning Statements for AC Systems jAdvertencia Al instalar el producto utilice los cables de conexi n previstos o designados los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el c digo de otros dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie Appareils lectrom nagers et de loi sur la s curit Mat riel interdit l utilisation de UL ou CSA c bles certifi s qui ont UL ou CSA indiqu sur le code pour tous les autres appareils lectriqu
39. T 5352 nnn n0 man Aa cle 52 gs gall d a Z Jel Aad Ae yaa OS 4 Lente 31 2 S42 gd SAW Backplane VE 2 5 Aol eju WY suc 412 9 Al 9 4 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het Systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes A Warning Installation of the equipment must comply with local and national electrical codes 7745 KO p oot OUR HEL Fi OUO EU Zo 35 3 O ERO a BUG ICS 5 238 245 0 897 We RDA IUE BSC FELD AA FF BUR FIL Warnung Die Installation der Gerate muss den Sicherheitsstandards entsprechen 4 14 Chapter 4 Warning Statements for AC Systems jAdvertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales zin DAWN pin own nmm Dp x xm 0779727973 Sownn mn nvno n n nipnn sib d al ill Bai GI casa th Gus 3 ox a 47 aol ure aser Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Product Di
40. U Select Enabled to support Intel Virtualization Technology which will allow one platform to run multiple operating systems and applications in independent partitions creating multiple virtual systems in one physical computer The options are Enabled and Disabled 7 5 SUPERSERVER 7047R TRF USER S MANUAL Note If there is any change to this setting you will need to power off and restart the system for the change to take effect Please refer to Intel s website for detailed information Clock Spread Spectrum Select Enabled to enable Clock Spectrum support which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed The options are Disabled and Enabled gt CPU Power Management Configuration This submenu allows the user to configure the following CPU Power Management settings Power Technology Select Energy Efficiency to support power saving mode Select Custom to customize system power settings Select Disabled to disable power saving settings The options are Disable Energy Efficient and Custom If Custom is selected the following options become available EIST EIST Enhanced Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation Please refer to Intel s web site for detailed information The options are Disabled and Enab
41. Voltage criterio 4 13 Comply with Local and National Electrical 4 14 ies He Oe 4 15 Hot Swap Fan Warming i ten nere ie eren rene 4 16 Power eet Bee le 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Senerboard ic acs o rr creer eat oct 5 1 51 5 5 1 UNPACKING eR E 5 1 5 2 Processor and Heatsink Installationen inaa 5 2 Installing a Passive CPU Heatsink 5 6 Removing the Heatsink 5 7 vii SUPERSERVER 7047R TRF USER S MANUAL 5 87 Connecting ele EE 5 8 Connecting Data Cables ri rait parent nb Ped Re oda cds 5 8 Connecting Power Cable Sineik ian 5 8 Connecting the Control Pariel rente t ttr 5 8 SA M ttegeessen 5 9 5 5 Installing MEMON cn eerte Maer dE 5 10 Memory Te GE 5 10 DIMM Module Population Configuration 5 11 5 6 Adding PGI Expansion Cards eri re eere eee 5 12 E ee RR EI 5 13 5 8 Gonnector Definitions err D Renee tke de i en rne a 5 16 5 9 Jumper Seting EE 5 23 TE welle Eelere Eil 5 23 EL We lee lge Ree e 5 25 5 11 SATA Drive Connections non nth entren rn ern rien 5 26 5 12 Installing Soft
42. WS 741P 1R Rated Output Voltages 12V 12A 5Vsb 5A Operating Environment Operating Temperature 0 to 60 C 32 to 140 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 2096 to 9596 non condensing Non operating Relative Humidity 5 to 9596 non condensing B 2 Appendix B System Specifications Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate B 3 SUPERSERVER 7047R TRF USER S MANUAL continued from front The products sold by Supermicro are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircraft aircraft devices aircraft emergency com munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermic
43. Ware Au 5 27 SuperDoctor lll TT 5 28 5 14 Battery sen 5 30 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive DEVICES er e tia i 6 1 tazen EP 6 1 6 2 Front Control Pariel citt rr etre eot eh ctae deret 6 2 6 9 System Fas etnies cc cud sc oe ndi Agen 6 4 6 4 6 4 Drive Bay Installations A E 6 6 SATA NEE 6 6 SATA Backplarie eed PR REED 6 7 tele Le Ee EE 6 8 6 5 JPoWer SUDDply erret esae aere e eerste 6 9 Power Supply Fal lS oet eret toco irre eret Ee 6 9 Chapter 7 BIOS 7 1 leie Ierd TEMOR 7 1 Starting E e OO EE 7 1 MOM xs 7 2 System Time System Dale n rti ce ere 7 2 7 3 Advanced Settings Menu 7 2 TA Event Logs iin ra tbi EC De abated eee riae rd 7 22 COMME JU 7 23 Table of Contents MEE EE 7 25 VE V EE 7 25 4 8 EE 7 26 Appendix A BIOS POST Error Codes Appendix B System Specifications Drive Bays te pee e ERE de cadi raa eeu EA B 1 Peripheral Drive Bays cde dive eerie us B 1 Expatisionilots iiic ip preise pease eva EE RE Pod B 1 KH DEE 2 SUPERSERVER 7047R TRF USER S MANUAL N
44. Wel SUPERSERVER 7047R TRF USER S MANUAL Waarschuwing Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel uit het chassis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing Power Cable and AC Adapter A Warning When installing the product use the provided or designated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malfunction or a fire Electrical Appliance and Material Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the code for any other electrical devices than products designated by Supermicro only PI FLACV RT A DMRS obo PURE SHE ENGL ilia FEA TRTA BAL HOT 7 27 AEE S bem Acca DES XH Zl ULEZECSASEO7 7JW UL CSEv Z25a Fix il SupermicroZ FS BLAST AC SEELEN SESE iat EERE HA a PEA RE zo ERY Supe rmi m BSH Te Ze EEL TS LE RE FHZRZEULERCSAVA TER CRA ES ASUL CSAFFS Tal Ba EE AR Se Ee I ES ECR OY 5 PEEK SE BRT Supermicro EKA m BIA oR STH CA S
45. ad plate that covers the CPU socket from its locking position Press down on Load the Lever Pull lever away labeled Close 1st from the socket 3 With the lever labeled Close 1st fully retracted gently push down on the Open 1st lever to open the load plate Lift the load plate to open it completely Gently push down to pop the load plate open 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket SUPERSERVER 7047R TRF USER S MANUAL 5 Use your thumb and index finger to hold the CPU on its edges Align the CPU keys which are semi circle cutouts against the socket keys Socket Keys 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Warning You can only install the CPU inside the socket in one direction Make sure that it is properly inserted into the CPU socket before closing the load plate If it doesn t close properly do not force it as it may damage your CPU Instead open the load plate again and double check that the CPU is aligned properly 5 4 Chapter 5 Advanced Serverboard Setup 7 With the CPU inside the socket inspect the four corners of the CPU to make sure that the CPU is properly installed 8 Close the load plate with
46. also included In addition two USB ports have been incorporated into the control panel to provide front side USB access UO Backplane The SC745TQ R920B is an extended ATX form factor chassis that may be used in either a tower or a 4U rackmount configuration The I O backplane provides seven tool less motherboard expansion slots one COM port one parallel port one VGA port two USB 2 0 ports PS 2 mouse and keyboard ports two gigabit Ethernet ports and a dedicated IPMI LAN port Cooling System The chassis has an innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chassis as well as two 8 cm hot plug exhaust fans located at the rear of the chassis An air shroud channels the airflow from the system fans to efficiently cool the processor area of the system The power supply module also includes a cooling fan 1 3 SUPERSERVER 7047R TRF USER S MANUAL 1 4 Advanced Power Management for F Models Only Intel Intelligent Power Node Manager NM The Intel Intelligent Power Node Manager IPNM provides your system with real time thermal control and power management for maximum energy efficiency Although IPNM Specification Version 1 5 is supported by the BMC Baseboard Management Controller your system must also have IPNM compatible Manageability Engine ME firmware installed to use this feature Manageability Engine ME The Manageability Engine which is an ARC c
47. appareil doit tre install e dans des zones d acc s r serv s L acc s une zone d acc s r serv n est possible qu en utilisant un outil sp cial un m canisme de verrouillage et une cl ou tout autre moyen de s curit 4 9 SUPERSERVER 7047R TRF USER S MANUAL nba av TIN nova sn PO nma wow OR mmn penn v 53335 PPB 3352 POR 75 Saba 5 eh 6 il bas ode Geared e dala sla JS h i sas iihi ll Ja ele el Alas s gl d c Gia y J A e alt 46 09 petu ee AAE AARAA SFE Wu 4 7 HE 7l Sas SANT As d t 99 EAA Yeu Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling A Warning There is the danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions BA OSB Dt idt A DHESET EM FOLO ZA PEO Ere Rid Bic He FEW ES m DES Dit FL E PERE ID Be FB SE
48. ase refer to Chapter 6 Checking the Airflow 1 Airflow is provided by four hot swap 8 cm chassis fans working in conjunction with an air shroud Two 8 cm exhaust fans are also mounted at the rear of the chassis The system component layout was carefully designed to promote sufficient airflow through the chassis Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans Keep this in mind when you reroute them after working on the system Supplying Power to the System The last thing you must do is to provide input power to the system 1 Plug the power cords from the power supplies unit into a high quality power strip that offers protection from electrical noise and power surges It is recommended that you use an uninterruptible power supply UPS Depress the power on button on the front of the chassis Chapter 2 Server Installation Rack Configuration shown 2 11 Figure 2 5 Accessing the Inside of the System f 22888888399527 ETP f SUPERSERVER 7047R TRF USER S MANUAL Notes 2 12 Chapter 3 System Interface Chapter 3 System Interface 3 1 Overview The control panel on the SUPERSERVER 7047R TRF has several LEDs and two buttons There are also two LEDs on each SATA drive carrier These LEDs keep you constantly inf
49. board Setup Figure 5 1 Front Control Panel Header Pins JF1 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various I O ports Figure 5 2 Rear Panel UO Ports 4 Li 1 COM Port 1 Turquoise 6 Back Panel USB Port 3 2 Back Panel USB Port 0 7 Gigabit LAN 1 3 Back Panel USB Port 1 8 Gigabit LAN 2 4 PMI_Dedicated LAN 9 Back Panel VGA Blue 5 Back Panel USB Port 2 5 9 SUPERSERVER 7047R TRF USER S MANUAL 5 5 Installing Memory Caution Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Memory Support The X9DRi F supports up to 512 GB of DDR3 1866 1600 1333 1066 800 MHz speed registered ECC 1GB 2GB 4GB 8GB 16GB and 32GB size SDRAM in 16 DIMM slots See the following table for memory installation Memory speed support is dependent on the type of CPU used on the board Installing Memory Modules 1 Insert the desired number of DIMMs into the memory slots starting with DIMM 1A For best memory performance please install memory modules of the same type and same speed on the memory slots as indicated on the tables below 2 Insert each DIMM module vertically into its slot Pay attention to the notch along the bottom of the module to av
50. compagnent cet appareil r f rez vous au num ro de l instruction situ la fin de chaque avertissement CONSERVEZ CES INFORMATIONS mms NAT mn bon 155 op nx vmm ni YY pns YY nnns AAA n n vp mx v nw mY Pappen IX NIRV WI TTPA NWR PD pasan ns IIT AR Pena PRVI 7252 22015 ONIDV 1900 mo Typ imnib3o O I 97F nan N NIPT 155 1815752 NDOT NN NIP v 4 2 Warning Statements for AC Systems 4 Sas Als eh Al pas elei Jl D l pha Sil gall ge Aal ele ele Seles cel gle Ath Sl Gaal ss sl E shy gil 48 ll GLA ule OSs pies US Adi ch all enia SAS ss 321 4x Se 9909 WSS be suu 9 ae AAS ze Qe JA BE e dat az 28 7 Ao 417 8 5 99252 SFU DAA AWS YAS 959 BE eT a mM BUCH 19 Ware 27 AA 7 arg vp Ee Alea Wes ael BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar U verkeert in een situatie die lichamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES 4 3
51. d faster than the connections of Parallel ATA See the table on the right for pin definitions 5 26 Chapter 5 Advanced Serverboard Setup 5 12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp ftp supermicro com Some of these must be installed such as the chipset driver After accessing the ftp site go into the CDR_Images directory and locate the ISO file for your motherboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure 5 5 should appear Figure 5 7 Driver Tool Installation Display Screen S SUPERMICRO X9DR3 i F Motherboard Drivers amp Tools WinXP Intel Chipset INF files SUPERMIC R Matrox G200e Graphics Driver Drivers amp Tools Microsoft Nei Framework Optional Intel C602 C606 Chipset X9DR3 i F LSI MegaRAID Storage Manager Intel Rapid Storage Technology Enterprise Intel PRO Network Connections Drivers Trusted Platform Module Driver Optional SUPERMICRO SuperDoctor III SUPERMICRO Computer Inc Bui
52. d Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit and press lt Enter gt When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS without saving the changes or click No to quit the BIOS and save changes Save Changes and Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration parameters can take effect Select Save Changes and Exit and press lt Enter gt When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS without saving the changes or click No to quit the BIOS and save changes Save Options Save Changes Select this option and press lt Enter gt to save all changes you ve done so far and retun to the AMI BIOS utility Program This will not reset reboot the system When the dialog box appears asking you if you want to save configuration click Yes to save the changes or click No to return to the BIOS without making changes Discard Changes Select this feature and press lt Enter gt to discard all the changes and return to the BIOS setup When the dialog box appears asking you if you want to load previ ous values click Yes to load the values previous saved or click No to keep the
53. d system temperatures See the table on the right for pin definitions Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened 5 20 Serial Port Pin Definitions COM1 COM2 Pin Definition Pin Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC NC No connection PWR LED Connector Pin Definitions JD1 Pin Setting Definition Pin 1 Anode Pin2 Cathode Pin3 NA Speaker Connector Pin Definitions Pin Setting Definition Pins 4 7 External Speaker Pins 6 7 Internal Speaker Default PWR SMB Pin Definitions JI2C1 Pin Definition 1 Clock 2 Data S PWR Fail 4 Ground 5 3 91 Chassis Intrusion Pin Definitions JL1 Pin Definition 1 Intrusion Input 2 Ground TPM Header Port 80 A Trusted Platform Module Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on the right for pin definitions Information Overheat LED Fan Fail The JOH1 header is used to connect an LED indicator to provide warnings of chassis overheating and fan failure This LED will blink when a fan failure occurs Refer to the tables on right for pin definitions IPMB A System Manag
54. der from bottom to top or from left to right if rackmounted A bezel covers the drive area but does not need to be removed to access the drives simply swing open the bezel If you wish to remove the bezel piece push on the three tabs on the inside of the left lip of the front chassis cover Then slightly swing out the same left side of the cover about 7 inch only Remove by pushing on the open side of the cover to remove it from the chassis do not try to swing or pull it straight out after opening the left side The drives are mounted in drive carriers to simplify their installation and removal from the chassis These drives are hot swappable meaning they can be removed and installed without powering down the system The carriers also work to promote proper airflow for the system For this reason even carriers without drives must remain in the server Warning Regardless of how many drives are installed all drive carriers must remain in the drive bays to promote proper airflow Warning Use extreme caution when working around the SAS SATA backplane Do not touch the backplane with any metal objects and make sure no cables touch the backplane or obstruct the airflow holes Warning Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro Web site at http www supermicro com products nfo files storage SAS CompList pdf Installing Removing
55. e Enabled and Disabled EHCI Controller 1 EHCI Controller 2 Select Enabled to enable Enhanced Host Interface EHCI Controller 1 or Controller 2 to improve overall platform performance The options are Enabled and Disabled Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support legacy USB debvices Select Auto to disable legacy support if USB devices are not present Select Disable to have USB devices available for EFI Extensive Firmware Interface applicatioins only The settings are Enabled Disabled and Auto 7 13 SUPERSERVER 7047R TRF USER S MANUAL Port 60 64 Emulation Select Enabled to enable UO port 60h 64h emulation support for the legacy USB keyboard so that it can be fully supported by the operating systems that do not recognize a USB device The options are Disabled and Enabled EHCI Hand off Select Enabled to enable support for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When enabled ownership change will be claimed by the EHCI driver The options are Disabled and Enabled gt SATA Configuration When this submenu is slected the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items SATA Port0 SATA Port5 The AMI BIOS displays the status of each SATA port as detected by the BIOS SATA Mode Use this feature to configure SATA mode for a selected SATA port The options are
56. e room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern SUPERSERVER 7047R TRF USER S MANUAL Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc 2 5 Installing the System into a Rack This section provides information on installing the system into a rack unit Rack installation requires the use of the optional rackmount kit If the system has already been mounted into a rack or if you are using it as a tower you can skip ahead to Sections 2 5 and 2 6 There are a variety of rack units on the ma
57. el PCH C606 Southbridge chipset BIOS 64 Mb AMIBIOS SPI Flash ROM Memory Capacity Sixteen 16 single dual tri quad channel DIMM slots supporting up to 512 GB of DDR3 1866 1600 1333 1066 800 MHz speed 1GB 2GB 4GB 8GB 16GB and 32GB size registered ECC SDRAM Note See the memory section in Chapter 5 for details SATA Controller Intel PCH C606 on chip controller for six port Serial ATA RAID 0 1 5 and 10 supported Drive Bays Eight hot swap drive bays to house eight SATA or SAS drives SAS requires optional SAS controller card default support is for six drives only Peripheral Drive Bays Three 5 25 drive bays Expansion Slots Three 3 Express 3 0 x16 card slots Slot2 Slot4 Slot6 and Three 3 Express 3 0 x8 slots Slot1 Slot3 Slot5 for standard size add on cards B 1 SUPERSERVER 7047R TRF USER S MANUAL Serverboard X9DRi F Extended ATX form factor Dimensions 12 00 L x 13 00 W 304 80 mm x 330 20 mm Chassis SC745TQ R920B tower 4U mini tower Dimensions as tower WxHxD 7 x 19 x 27 in 178 x 483 x 686 mm Weight Gross Bare Bone 70 Ibs 31 8 kg System Cooling Three 3 8 cm system cooling fans Two 2 8 cm rear exhaust fans One 1 air shroud System Input Requirements AC Input Voltage 100 230V AC auto range Rated Input Current 9A 4A Rated Input Frequency 50 to 60 Hz Platinum 90 Platinum Level Power Supply Rated Output Power 920 Watt Part P
58. ement Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB connection on your system 5 21 Chapter 5 Advanced Serverboard Setup TPM Port 80 Header Pin Definitions JTPM1 Definition LCLK LFRAME LRESET LAD 3 3 3V LADO SMB CLK4 3V DUAL GND LPCPD Pin Definition 2 GND lt KEY gt 5V X LAD 2 LAD1 GND SMB_DAT4 SERIRQ CLKRUN X LDRQ X Overheat LED Pin Definitions JOH1 Pin Definition 1 VDC 2 OH Active Information OH Fan Fail LED Status State Message Solid Overheat Blinking Fan Fail IPMB Header Pin Definitions JIPMB1 Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection SUPERSERVER 7047R TRF USER S MANUAL T SGPIO 1 2 Headers Two SGPIO Serial Link General Purpose Input Output headers are located on the motherboard These headers support Serial_Link interface for onboard SATA connections See the table on the right for pin definitions BIOS Recovery JP3 BIOS Recovery is used to enhance system performance and power efficiency In the single operation mode online upgrade will be available via Recovery mode See the table on the right for pin definitions Legacy Wake On LAN Header JSTBY The onboard LAN por ts do not need a WOL header to support their Wake On LAN function Instead the legacy WOL header was preserved JSTBY to
59. er cord removed from the power supply module s before accessing the chassis interior to install or remove system components HEROD Eg VAF LAY HAY bOMOMG TE LE WMD DL Vy YAM ILA 3 cli VAFLOEPUETS TOY 2 dn UIE BIA BSE 2 VY SIRO 00705089 EMITAN AEA BT re ET A LIER IDES ER Chapter 4 Warning Statements for AC Systems Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Versorgungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen jAdvertencia El sistema debe ser disconnected de todas las fuentes de energ a del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me opp PINI IDA TIAN Von v op nrmpn Don nx v D nn mon IN Popp Tm maion 70 sang pon nu 155 Waal Baa Gye el jg SIE Ls Al e 80
60. es que les produits d sign s par Supermicro seulement AC a bpun FON UN AC DARNA OPPO 05353 v nnum WIAA pns 18 n pn 01142 915 IN 525 992 neg 15 OW 1510 ym TION OP pim Dawn PWIA VPY 5 YY sn xp Ow mp Drog gp RVI CSA 2 18 UL 2 250157 072222 Wanwn 7292 TIP OPIDIO VY PIL VAWT II 25 129 UL CSA diols gst EA di uS bel Sigal cas pats 22 OY asas g AN j dhe Gi gas ef Gat 5 GY g GUIS cal ol ill gial dl la UL j CSA COUN daniel jas gld al ga g Ro w l 5 Supermicro J ja Aisall eS 3 T UL CSA Aale Jas ill AI AFS xe qe ASHAU 442 AAAS AAAS AVS yok qug ss GS ASSO WH HE Sale 99 47 Se Electrical Appliance and Material Safety Law 2 THIEN 449 ASS sep He Ge 47 345 Het ULHE CSANA 91 AJE AA AA UL CSA 354 SS ASS suu 4 19 SUPERSERVER 7047R TRF USER S MANUAL Waarschuwing Bij het installeren van het product gebruik de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen 4
61. eses Warnsymbol bedeutet Gefahr Sie befinden sich in einer Situation die zu Verletzungen f hren kann Machen Sie sich vor der Arbeit mit Ger ten mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen die zusammen mit diesem Ger t ausgeliefert wurden BEWAHREN SIE DIESE HINWEISE GUT AUF INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este s mbolo de aviso indica peligro Existe riesgo para su integridad f sica Antes de manipular cualquier equipo considere los riesgos de la corriente el ctrica y familiaricese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el texto traducido en el apartado de traducciones que a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entrainer des blessures ou des dommages corporels Avant de travailler sur un quipement soyez conscient des dangers li s aux circuits lectriques et familiarisez vous avec les proc dures couramment utilis es pour viter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de s curit traduites qui ac
62. et 4 Ground PWR Fail LED Pin Definitions JF1 5 6 Pin Definition 3 3V PWR Supply Fail OH Fan Fail LED Pin Definitions JF1 Pin Definition 3f Vcc 8 Control OH Fan Fail LED Status State Indication Solid Overheat Blinking Fan fail NIC2 LED Pin Definitions JF1 Pin Definition 9 Vcc 10 Ground NIC1 LED Pin Definitions JF1 Pin Definition 11 Vcc 12 Ground SUPERSERVER 7047R TRF USER S MANUAL HDD LED HDD LED The HDD LED connection is located Pin on pins 13 14 of JF1 Attach the hard drive LED cable here to display Pin Definition disk activity for any hard drives on the EE system including SAS Serial ATA and IDE See the table the right for pin definitions Power On LED Power LED The Power On LED connector is Bin E located on pins 15 and 16 of JF1 This connection is used to provide LED Pin Definition 15 5V Stb indication of power being supplied to EX the system See the table on the right 16 Control for pin definitions NMI Button NMI Button The non maskable interrupt button Pin SUED A header is located on pins 19 and 20 of JF1 Refer to the table on the right Pin Definition e 19 Control for pin definitions uds 20 Ground Ethernet Ports LAN Ports Two Gigabit
63. f the CPU as detected by the BIOS It also allows the user to configure CPU settings P Socket 0 CPU Information This submenu displays the following information regarding the CPU installed in Socket 0 Type of CPU CPU Signature Microcode Patch CPU Stepping Maximum CPU Speed Minimum CPU Speed Processor Cores Intel HT Hyper Threading Technology Intel VT x Virtualization Technology Intel SMX Trusted Execution Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache P Socket 1 CPU Information This item displays if a CPU is installed in Socket 1 CPU Speed This item displays the speed of the CPU installed in Socket 1 64 bit This item indicates if the CPU installed in Socket 1 supports 64 bit technology Hyper threading Select Enabled to support Intel Hyper threading Technology to enhance CPU performance The options are Enabled and Disabled 7 4 Chapter 7 BIOS Active Processor Cores Set to Enabled to use a processor s Second Core and beyond Please refer to Intel s web site for more information The options are All 1 2 and 4 Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value Enable this function to boot the legacy operating systems that cannot support processors with extended CPUID functions The options are Enabled and Disabled for the Windows OS Execute Disable Bit Capability Available if supported by the OS amp
64. fety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow the hot plug SATA drives and power supply modules to cool before touching them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling 2 2 Chapter 2 Server Installation Rack Mounting Considerations A Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack f the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of th
65. for LAN1 Option ROM is Enabled the default setting for LAN2 Option ROM is Disabled VGA Priority Use this feature to specify which graphics controller to be used as the primary boot device The options are Onboard and Offboard VGA Network Stack Select Enabled to enabel PXE Preboot Execution Environment or Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled gt Super IO Configuration WPCM450 Super IO Chip Displays the Super IO chip type P Serial Port 0 Configuration Serial Port 1 Configuration The submenus allow the user to configure the following settings for Serial Port 0 or Serial Port 1 Serial Port Select Enabled to enable a serial port specified by the user The options are Enabled and Disabled 7 17 SUPERSERVER 7047R TRF USER S MANUAL Serial Port Mode This feature allows the user to set the serial port mode for Console Redirection The options are SOL and COM Device Settings This feature indicates whether or not a reset is required for a serial port specified Change Settings This option specifies the base UO port address and the Interrupt Request address of Serial Port 1 and Serial Port 2 The options for Serial Port 1 and Port 2 are Auto IO23F8h IRQ 4 IOz3F8h IRQ 3 4 5 6 7 9 10 11 12 IOz2F8h IRQ 3 4 5 6 7 9 10 11 12 IOz3E8h IRQ 3 4 5 6 7 9 10 11 12 IOz2bE8h IRQ 3 4 5 6 7 9 10 11 12
66. g the system keep the airflow in mind when routing the cables The following data cables with their connector locations noted should be connected See the serverboard layout diagram in this chapter for connector locations e SGPIO cables T SGPIO 1 2 SATA cables i SATA 0 5 e Control Panel cable JF1 see next page Connecting Power Cables The X9DRi F has a 24 pin primary power supply connector designated JPWR3 for connection to the ATX power supply Connect the appropriate connector from the power supply to JPWR3 to supply power to the serverboard See the Connector Definitions section in this chapter for power connector pin definitions In addition your power supply must be connected to the two 8 pin Processor Power connectors at JPWR1 and JPWR2 Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel buttons and LED indicators Even and odd numbered pins are on opposite sides of each header All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection The red wire in the ribbon cable plugs into pin 1 of JF1 Connect the other end of the cable to the Control Panel printed circuit board located just behind the system status LEDs in the chassis See the Connector Definitions section in this chapter for details and pin descriptions of JF1 5 8 Chapter 5 Advanced Server
67. h time the system is powered on errors may occur Non fatal errors are those which in most cases allow the system to continue the boot up process The error messages normally appear on the screen Fatal errors are those which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the exception of Beep Code 8 are fatal errors 1 AMIBIOS Error Beep Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short beeps and 1 Memory error No memory detected in the system long beep 5 long and 2 short Display memory Video adapter missing or with faulty memory beeps read write error 1 Continuous beep System OH System Overheat 1 SUPERSERVER 7047R TRF USER S MANUAL Notes Appendix B System Specifications Appendix B System Specifications Processors Dual Intel E5 2600 V2 series series Socket R LGA2011 type processors Note You must install at least two processors for full functions to be supported Note Please refer to our web site for a complete listing of supported processors Chipset One Intel PCH C602 chipset and one Int
68. ies two rail mounting brackets and mounting screws needed for installing the system into a rack optional kit Follow the steps in the order given to complete the installation process in a minimum amount of time Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow 2 1 SUPERSERVER 7047R TRF USER S MANUAL Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches and approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing This product is not suitable for use with visual display work place devices acccording to 2 of the the German Ordinance for Work with Visual Display Units Warnings and Cautions Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Slide rail mounted equipment is not to be used as a shelf or workspace Server Precautions Review the electrical and general sa
69. ions RAIDKey Header A RAIDKey header JRK1 provides RAID function support to enhance system performance 5 19 Chapter 5 Advanced Serverboard Setup FP USB 4 5 8 9 10 11 USB 6 Pin Definitions USB 4 8 10 6 7 USB 5 9 11 Pin Definition Pin Definition 1 5V 1 5V 2 2 3 PO 3 PO 4 Ground 4 Ground 5 NC 5 Key NC No connection Backplane USB 0 1 2 3 Pin Definitions Pin Definition 1 5V 2 PO 3 PO 4 Ground 5 NA Fan Header Pin Definitions Pin Definition 1 2 12V 3 Tachometer 4 PWR Modulation RAIDKey Pin Definitions Pin Definition 1 Signal 0 2 3 Signal 1 SUPERSERVER 7047R TRF USER S MANUAL Serial Ports Two COM connections COM1 COM2 are located on the motherboard COM1 is located on the Backplane UO panel COM2 located close to PCI E Slot1 provides front access support See the table on the right for pin definitions Power LED Speaker On JD1 header pins 1 3 are used for power LED indication and pins 4 7 are for the speaker See the tables on the right for pin definitions Please note that the speaker connector pins 4 7 are used with an external speaker If you wish to use the onboard speaker you should close pins 6 7 with a jumper Default Power SMB Connector Power System Management Bus I2C Connector JI2C1 monitors power supply fan an
70. ions are Enabled and Disabled P SAS Configuration If a SAS port is detected in the system the following items will be displayed SCU Devices Select Enabled to enable support for PCH SCU System Configuration Utility devices The options are Disabled and Enabled OnChip SAS Oprom Select Enabled to support the onboard SAS Option ROM to boot up the system via a storage device if a SAS device is installed The options are Disabled and Enabled SCU Port 0 7 The SCU devies detected by the BIOS will be displayed 7 15 SUPERSERVER 7047R TRF USER S MANUAL gt Thermal Configuration Thermal Management Select Enabled to initialize the PCH Thermal subsystem device The options are Enabled and Disabled If Enabled is selected the following item appears gt PCle PCI PnP Configuration This submenu allows the user to configure the following PCle PCI PnP settings PCI ROM Priority Use this feature to select the Option ROM to boot up the system when there are multiple Option Roms available in the system The options are Legacy ROM and Compatible ROM PCI Latency Timer Use this feature to set the latency timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a device that supports 64 bit in the space above 4G
71. ivity while the green LED on the left indicates the speed of the Color Status Definition connection See the tables at right for Off Off No Connection more information Green Link 100 Mb s Solid Speed Left Amber Activity Active Blinking Right 5 25 SUPERSERVER 7047R TRF USER S MANUAL Onboard Power LED Onboard PWR LED Indicator An Onboard Power LED is located FED Settings LET LED Col Definiti at LE1 on the motherboard When er Off System Off PWR cable not this LED is on the system is on Be connected sure to turn off the system and unplug Green System On the power cord before removing or Green Flashing ACPI S1 State installing components See the tables Quickly at right for more information BMC Heartbeat LED BMC Heartbeat LED A BMC Heartbeat LED is located at Status DM1 Color State Definition DM1 on the motherboard When DM1 is blinking BMC functions normally See the table at right for more information Green Blinking BMC Normal 5 11 SATA Drive Connections Serial ATA Ports SATA Ports Pin Definitions There are six Serial ATA Ports SATA0 SATA3 I SATAO I SATA 5 located on the Pin Definition Pin Definition motherboard I SATA 0 1 support 1 Gem 2 Rs SATA 3 0 and I SATA 2 5 are SATA 2 TXP 6 RXP 2 0 ports These ports provide serial 3 TX_N 7 Ground link signal connections which are 4 Groun
72. jumping pins 1 and 2 Refer to the motherboard layout page for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins CMOS Clear JBT1 contact pads JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s It is also recommended that you remove the onboard battery from the serverboard 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver 3 Remove the screwdriver or shorting device 4 Reconnect the power cord s and power on the system Note 1 For an ATX power supply you must completely shut down the system remove the AC power cord and then short JBT1 to clear CMOS Note 2 Be sure to remove the onboard CMOS Battery before you short JBT1 to clear CMOS Note 3 Clearing CMOS will also clear all passwords Note 4 Do not use the PW_ON connector to clear CMOS 5 23 SUPERSERVER 7047R TRF USER S MANUAL LAN Enable Disable JPL1 enables or disables the GLAN Port1 GLAN Port2 on the motherboard See the table on the right for jumper settings The default setting is Enabled Watch Dog Enable Disable Watch Dog JWD is a system monitor that will reboot the system when a software application hangs Close Pi
73. ld driver diskettes and manuals Browse CD Auto Start Up Next Time For more information please visit SUPERMICAO s web 5 27 SUPERSERVER 7047R TRF USER S MANUAL Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these items to install each item from top to the bottom one at a time After installing each item you must re boot the system before moving on to the next item on the list The bottom icon with a CD on it allows you to view the entire contents SuperDoctor III The SuperDoctor Ill program is a web based management tool that supports remote management capability It includes Remote and Local Management tools The local management is called SD III Client The SuperDoctor Ill program allows you to monitor the environment and operations of your system SuperDoctor III displays crucial system information such as CPU temperature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor 111 is ADMIN ADMIN Note When SuperDoctor Ill is first installed it adopts the temperature threshold settings that have been set in BIOS Any subsequent changes to these thresholds must be made within SuperDoctor III as the SuperDoctor III settings override the BIOS settings To set the BIOS temperature threshold settings again you would fi
74. led Turbo Mode This feature allows processor cores to run faster than marked frequency in specific conditions The options are Disabled and Enabled P STATE Coordination This feature selects the type of coordination for the P State of the processor P State is a processor operational state that reduces the processor s voltage and frequency This makes the processor more energy effiicient resulting in further gains The options are HW_ALL SW_ALL and SW ANY CPU C3 Report CPU C6 Report CPU C7 Report This BIOS feature enables or disables C3 C6 and C7 reporting to the operating system The options for C3 and C7 are Disabled and Enabled The options for C6 are Disabled and Enabled Package C State Limit If set to Auto the AMI BIOS will automatically set the limit on the C State package register The options are C2 C6 C7 and No Limit 7 6 Chapter 7 BIOS Energy Performance The options are Performance Balanced Performance Balanced Energy and Energy Efficient Factory Long Duration Power Limit This item displays the power limit set by the manufacturer during which long duration power is maintained Long Duration Power Limit This item displays the power limit set by the manufacturer during which long duration power is maintained Factory Long Duration Maintained This item displays the period of time set by the manufacturer during which long duration power is maintained Long Duration Maintained
75. mation CPU Socket 1 DIMM Information CPU Socket 2 DIMM Information The status of the memory modules detected by the BIOS will be displayed Memory Mode When Independent is selected all DIMMs are available to the operating system When Mirroring is selected the motherboard maintains two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring Lockstep and Sparing DRAM RAPL BWLIMIT This item sets the limits on the average power consumption and the bandwidth of a DRAM module in operation so that the OS can manage power consumption and energy budget of hardware more effectively within a certain window of time The options are 0 1 8 and 16 Perfmon and DFX Devices A PerfMon device monitors the activities of a remote system such as disk usage memory consumption and CPU load which will allow an IT administrator to maximize the performance of each computer within the network A DFX device usually in the form of a USB adaptor can be used to enhance audio performance Select Unhide to display the Perfmon and DXF devices installed in the system The options are HIDE and UNHIDE 7 11 SUPERSERVER 7047R TRF USER S MANUAL DRAM RAPL Mode RAPL which stands for Running Average Power Limit is a feature that provides mechanisms to enforce power consumption limits on supported processor
76. must be connected to the JF1 connector on the serverboard to provide you with system status and alarm indications A ribbon cable has bundled these wires together to simplify this connection Connect the cable from JF1 on the serverboard making sure the red wire plugs into pin 1 to the appropriate comnnector on the front control panel PCB printed circuit board Pull all excess cabling over to the control panel side of the chassis The LEDs on the control panel inform you of system status See Chapter 3 for details See Chapter 5 for details on JF1 Chapter 6 Advanced Chassis Setup 6 3 SUPERSERVER 7047R TRF USER S MANUAL 6 3 System Fans Three 8 cm chassis cooling fans located in the center of the chassis provide cooling airflow while two 8 cm exhaust fans expel hot air from the chassis The chassis is also fitted with an air shroud to concentrate the flow of cooling air over the areas of highest generated heat The fans should all be connected to headers on the serverboard see Chapter 5 Each power supply module also has a cooling fan Fan Failure Under normal operation all three chassis fans both exhaust fans and the power supply fans run continuously The chassis fans and the exhaust fans are hot swappable and can be replaced without powering down the system Replacing Chassis Cooling Fans 1 First remove the top left chassis cover see Chapter 2 for details on removing the cover to locate the fan that has st
77. n heatsink attached See Chapter 5 for instructions on processor installation Your server may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 If desired you can install add on cards to the system See Chapter 5 for details on installing PCI add on cards Make sure all power and data cables are properly connected and not blocking the chassis airflow See Chapter 5 for details on cable connections 2 9 SUPERSERVER 7047R TRF USER S MANUAL 2 7 Checking the Drive Bay Setup Next you should check to make sure the peripheral drives and the hard drives and backplane have been properly installed and all connections have been made Checking the Drives 1 All drives can be accessed from the front of the server For servicing the optional DVD ROM and IDE hard drives you will need to remove the top left chassis cover The hard drives can be installed and removed from the front of the chassis without removing any chassis covers To install components into the 5 25 drive bays you must first remove the top left chassis cover as described in the previous section Refer to Chapter 6 for details Refer to Chapter 6 if you need to reinstall a optional DVD ROM disk drive to the system Depending upon your system s configuration your system may have one or more drives already installed If you need to install hard drives ple
78. n introduction to BIOS and provides detailed information on running the CMOS Setup Utility Appendix A BIOS POST Error Codes Appendix B Installing Windows Appendix C System Specifications Preface Notes SUPERSERVER 7047R TRF USER S MANUAL Table of Contents Chapter 1 Introduction 1 1 1 2 1 3 1 4 Overview Processors INGUIN OF EE Serial ATA Onboard eet Ee 1 2 Graphics Controller 1 2 ug c 1 3 Server Chassis FealtU res ruine ette per eh ride reti 1 3 System Enc Rune PL ed mee 1 3 Front Control Panel ttt aen ener p ge 1 3 effet le et LEE 1 3 Cooling System 1 3 Advanced Power Management for F Models Only 1 4 Intel Intelligent Power Node Manager 1 4 Manageability Engine roro coepere t opere pne rehenes 1 4 een Ee e Lee EEN 1 6 Chapter 2 Server Installation 2 1 2 2 2 3 2 4 e Unpacking the System FSD ALIN GAO 2S SOU EE Choosing WEE e AT EE Warningstand Cautions rater bene Bree o bata eer dogs Rack Precautiolis ir enr ceni terree n p S e ead raa 5 CPC Rack Mounting Considerations Ambient Operating Temperature 2 3 Reduced AinlOW ssiri M 2 3 ewe Reen Le EE 2 3 Circuit
79. nnect these power supply connectors to the 24 pin power connector JPWR3 and two 8 pin power connectors JPWR1 JPWR2 on the motherboard Failure in doing so will void the manufacturer warranty on your power supply and motherboard 5 15 SUPERSERVER 7047R TRF USER S MANUAL 5 8 Connector Definitions Power Connectors ATX Power 24 pin Connector A 24 pin main power supply Pin Definitions JPWR3 connector JPWR3 and two 8 pin Pin Definition Pin Definition CPU PWR connectors JPWR1 2 19 sso are located on the motherboard 14 12V 2 93V These power connectors meet the SSI 15 COM 3 COM EPS 12V specification These power 16 PS ON 4 45V connectors must also be connected to 47 5 COM your power supply See the table on FERT 6 RES the right for pin definitions 19 COM 7 Warning To provide adequate power supply to the motherboard 20 Res NC 8 PWR_OK 21 5V 9 5VSB be sure to connect the 24 pin ATX PWR JPWR3 and two 8 PWR IPSE connectors JPWR1 JPWR2 to the Se ER 027 power supply Failure to do so will void 24 COM 12 3 3V the manufacturer warranty on your power supply and motherboard 12V 8 pin PWR Connector Pin Definitions JPWR1 2 Pins Definition 1 through 4 Ground 5 through 8 12V Required Connections PW ON Connector Power Button Pin Definitions JF1 Pin Definition The Power Button connec
80. ns 1 2 to reset the system if an application hangs Close Pins 2 3 to generate a non maskable interrupt signal for the application that hangs See the table on the right for jumper settings Watch Dog must also be enabled in the BIOS VGA Enable Disable Jumper JPG1 allows the user to enable the onboard VGA connector The default setting is 1 2 to enable the connection See the table on the right for jumper settings BMC Enable Jumper JPB1 allows you to enable the embedded WPCM 450 BMC Baseboard Management Controller to provide IPMI 2 0 KVM support on the motherboard See the table on the right for jumper settings Write_Protect Enable Close pins 1 2 of Jumper JWP1 to enable Write_Protect support for system security and data integrity See the table on the right for jumper settings 5 24 LAN Enable Disable Jumper Settings JPL1 Jumper Setting Definition 1 2 Enabled default 2 3 Disabled Watch Dog Enable Disable Jumper Settings JWD Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled VGA Enable Disable Jumper Settings JPG1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled BMC Enable Disable Jumper Settings JPB1 Jumper Setting Definition Pins 1 2 BMC Enable Default Pins 2 3 Disabled Write Protect Enable Disable Jumper Settings JWP1 Jumper Setting Definition
81. ns out to be a correctable error the error is corrected and sent to the requestor the original Source Memory is updated as well Select Enabled to use Demand Scrubbing for ECC memory correction The options are Enabled and Disabled Data Scrambling Select Enabled to enable data scrubbing and ensure data security and integrity The options are Disabled and Enabled 7 12 Chapter 7 BIOS DRAM RAPL RAPL which stands for Running Average Power Limit is a feature that provides mechanisms to enforce power consumption limits on supported processors The options are Mode 0 MODE1 and Disabled Device Tagging Select Enabled to support device tagging The options are Disabled and Enabled Thermal Throttling Throttling improves reliability and reduces power consumption in the processor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttling OLTT Peak BW Use this feature to set a percentage of the peak bandwidth allowed for OLTT Enter a number between 25 to 100 The default setting is 50 gt South Bridge This feature allows the user to configure the settings for the Intel PCH chip PCH Information This feature displays the following PCH information Name This item displays the name of the PCH chip Stepping This item displays the status of the PCH stepping All USB Devices Select Enabled to enable all onboard USB devices The options ar
82. oid installing incorrectly see Figure 5 3 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules To Install Insert module vertically and press down until it snaps into place Pay attention to the alignment notch at the bottom To Remove Use your thumbs to gently push the release tabs near both ends of the module This should release it from the slot Figure 5 3 Installing DIMM into Slot Notch Release Tab Notch d Note Notch should align with the receptive key point on the slot Release Tab p Top View of DDR3 Slot 5 10 Chapter 5 Advanced Serverboard Setup Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU1 P1 A1 P1 B1 P1 C1 P1 D1 P1 A2 1 2 P1 C2 P1 D2 CPU2 P2 E1 P2 F1 P2 G1 P2 H1 P2 E2 P2 F2 P2 G2 P2 H2 Processor and Memory Module Population Number of CPU and Memory Population Configuration Table CPUs DIMMs For memory to work proper please install DIMMs in pairs 1 CPU amp CPU1 2 DIMMs P1 A1 P1 B1 1CPU amp 4 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 1 CPU amp 5 8 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 Any memory pairs P1 A2 B2 C2 D2 DIMM slots 2 CPUs amp CPU1 CPU2 4 DIMMs P1 A1 P1 B1 P2 E1 P2 F1 2 CPUs amp CPU1 2 6 DIM
83. ontroller embedded in the IOH I O Hub provides Server Platform Services SPS to your system The services provided by SPS are different from those proveded by the ME on client platforms 1 4 Chapter 1 Introduction Figure 1 1 Intel PCH C602 C606 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details PCI E X16 G3 PCI E X16 G3 PCI E X16 G3 PCI E X8 G3 PCI E X8 G3 PCI E X8 G3 PCI E X4 G3 o 2 a E a SUPERSERVER 7047R TRF USER S MANUAL 1 4 Contacting Supermicro Headquarters Address Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A Tel 1 408 503 8000 Fax 1 408 503 8008 Email marketing supermicro com General Information support supermicro com Technical Support Web Site www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma gsupermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 23511 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Web Site www supermicro com tw Technical Support Email support supermicro com tw Tel 886 2 8226 3990 1 6 Chapter 2 Server Installation
84. opped working 2 Depress the locking tab on the failed fan on a chassis fan push the tab on the side of the housing inward on the exhaust fan push down on the colored tab With the tab depressed pull the unit straight out see Figure 6 3 The wiring for these fans has been designed to detach automatically 3 Replace the failed fan with an identical one Install it in the same position and orientation as the one you removed it should click into place when fully inserted Check that the fan is working then replace the top left side chassis panel Removing the Air Shroud Under most circumstances you will not need to remove the air shroud to perform any service on the system However if you wish to temporarily remove it the air shroud should always be in place when the system is operating please follow this procedure 1 Begin by depressing the tabs at the front and rear of the shroud to unlock it 2 Lift the air shroud up and out of the chassis see Figure 6 4 3 To reinstall simply position the air shroud in its proper place and push it in until you hear it click 6 4 Chapter 6 Advanced Chassis Setup Figure 6 3 Removing a Chassis Fan 5 287 3 8 EC Figure 6 4 Removing the Air Shroud 6 5 SUPERSERVER 7047R TRF USER S MANUAL 6 4 Drive Bay Installation SATA Drives A total of six SAS or SATA drives may be housed in the SC745 chassis The drive IDs are preconfigured as 0 through 5 in or
85. ormed of the overall status of the system and the activity and health of specific components 3 2 Control Panel Buttons There are two push buttons located on the front of the chassis a power on off button and a reset button Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system RESET i 1 1 1 K Reset Use the reset button to reboot the system 3 1 SUPERSERVER 7047R TRF USER S MANUAL 3 3 Control Panel LEDs The control panel located on the front of the SC745 chassis has six LEDs that provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any corrective action you may need to take sil Power Indicates power is being supplied to the system s power supply This LED should normally be on when the system is operating g HDD Indicates SATA drive activity when flashing mu m NIC1 Indicates network activity on LAN1 when flashing CI dE NIC2 Indicates network activity on LAN2 when flashing 3 2 Chapter 3 System Interface O Information LED See the following table for the status shown by this LED
86. otes Chapter 1 Introduction 1 1 Chapter 1 Introduction Overview The SUPERSERVER 7047R TRF is a high end server comprised of two main subsystems the SC745TQ R920B 4U tower chassis and the X9DRi F serverboard Please refer to our web site for information on operating systems that have been certified for use with the system www supermicro com In addition to the serverboard and chassis various hardware components have been included with the 7047R TRF as listed below Two 2 passive CPU heatsinks SNK P0048PS Three 3 8 cm system fans FAN 0074L4 Two 2 8 cm rear exhaust fans FAN 0082L4 One 1 air shroud MCP 310 49001 0N One 1 20 front control 16 to 16 pin ribbon cable CBL 0087 Four 4 200 mm 4 to 4 Pin Middle Fan Power Extension cables CBL 0216L SAS Accessories One 1 SAS backplane BPN SAS 743TQ Two 2 40 cm 8 to 8 pin ribbon cable w tube for SGPIO CBL 157L Six 6 35 cm SATA cables CBL 0061L Eight 8 3 5 drive trays MCP 220 00092 0B One rackmount kit Optional CSE PT26 Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety information http super dev about policies safety information cfm If you have any questions please contact our
87. ound as a locking tab emerges from inside the rail assembly and locks the inner rail Depress the locking tab to pull the inner rail completely out Do this for both assemblies one for each side 2 4 Chapter 2 Server Installation Figure 2 1 Identifying the Sections of the Rack Rails ter Inner ail ets 2 5 SUPERSERVER 7047R TRF USER S MANUAL Installing the Chassis Rails You will need to remove the top cover and the feet to add rack rails to the chassis First remove the top and right covers top and left covers when standing as a tower chassis by first removing the screws that secure them to the chassis Depress the button on the top side if tower of the chassis to release the cover and then pull the cover off Then unscrew the four feet and remove them from the chassis see Figure 2 2 You can now attach rack rails to the top and bottom now the sides of the chassis First add the rack handles Then position the inner chassis rail sections you just removed along the side of the chassis making sure the screw holes line up Note that these two rails are left right specific Screw the rail securely to the side of the chassis see Figure 2 3 Repeat this procedure for the other rail on the other side of the chassis You will also need to attach the rail brackets when installing into a telco rack Locking Tabs As mentioned the chassis rails have a locking tab which serves two functions The first i
88. p designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard Unpacking The serverboard is shipped in antistatic packaging When unpacking the board make sure the person handling it is static protected 6 1 SUPERSERVER 7047R TRF USER S MANUAL Figure 6 1 Chassis Front View Main Power System Reset USB Ports Dail Oo0000 5 25 Drive lt System LEDs D D oo DO D D D SuPERO o000000000 OO0000000000 8 Drive Bays behind locking bezel OU OC DU Lk les OO Jes OL Je E 6 2 Front Control Panel The front control panel
89. po FAAL Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden 4 11 SUPERSERVER 7047R TRF USER S MANUAL Redundant Power Supplies A Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit TUES CO m MESO BYES VCO 75083 Lay WSOC TN TORE MONE EU EE Ie ARE REA FEE AT BES SCRE ATS LEER AE E x CE BEREAN Bi Te LI ll JE I Be Er LEES m r Warnung Dieses Gerat kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden jAdvertencia Puede que esta unidad tenga mas de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant lectrique de l unit toutes les connexions d alimentation doivent tre d branch es INN pbon 5n op rmx TPN ny emn 25 von v 70 INR mno anm v mm
90. provide convenience for some embedded customers who need an internal power source from the board See the table on the right for pin definitions DOM Power Connector A power connector for SATA DOM Disk_On_Module devices is located at JWF1 Connect an appropriate cable here to provide power support for your DOM devices Video Connection A Video VGA port is located next to LAN2 on the I O backplane Refer to the board layout below for the location 5 22 SGPIO Header Pin Definitions T SGPIO1 T SGPIO2 Pin Definition Pin Definition 1 NC 2 Data In 3 Ground 4 Data Out 5 Load 6 Ground 7 Clock 8 NC NC No Connection ME Recovery Pin Definitions Pin Definition 1 No Connection 2 Signal 3 Ground Legacy Wake On LAN Header Pin Definitions JSTBY Pin Definition 1 5V Standby 2 Ground 3 Wake up signal DOM Power Connector Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Chapter 5 Advanced Serverboard Setup 5 9 Jumper Settings Connector Pins Explanation of Jumpers To modify the operation of the E Jumper motherboard jumpers can be used to choose between optional settings Jumpers create shorts between two SC ES pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board See the diagram at right for an example of
91. ption State Status DM1 BMC Heartbeat LED Green BMC Normal LE1 Standby PWR LED Green On SB Power On 5 14 Chapter 5 Advanced Serverboard Setup Connector Description COM1 COM2 Backplane COM Port1 Front Accessible COM2 Header FAN1 6 FAN A FAN B CPU System Fan Headers I SATA 0 1 Intel SB SATA 3 0 Connectors 0 1 Color White I SATA 2 5 Intel SB SATA 2 0 Connectors 2 5 Color Black J22 JPWR3 ATX 24 Pin Power Connector JPWR1 2 12V 8 Pin Power Connectors JD1 Speaker Power LED Indicator JF1 Front Panel Control Header JIPMB1 4 pin External BMC Header for an IPMI Card JL1 Chassis Intrusion JOH1 Overheat LED Indicator JP3 BIOS Recovery Power Supply SMBbus l C Header JRK1 SAS RAID Key JSTBY1 Standby Header JTPM1 TPM Trusted Platform Module Port 80 JWF1 SATA DOM Disk on Module Power Connector LAN1 LAN2 1G LAN Ethernet Ports 1 2 IPMI LAN Dedicated LAN SAS 0 3 4 7 Serial Attached SCSI Connectors 0 3 4 7 SP1 Onboard Buzzer Internal Speaker Slot2 Slot4 Slot6 PCI Express 3 0 x16 Slot1 Slot3 Slot5 PCI Express 3 0 x8 T SGPIO 1 2 Serial Link General Purpose I O Headers BP USB 0 1 2 3 Back Panel USB 0 1 2 3 USB 4 5 USB 6 USB 8 9 USB Front Panel Accessible USB Connections 10 11 VGA Backpanel VGA Port Warning To prevent damage to the power supply or motherboard please use a power supply that contains a 24 pin and two 8 pin power connectors Be sure to co
92. resolution support The options are Disabled and Enabled 7 19 SUPERSERVER 7047R TRF USER S MANUAL Legacy OS Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty Keypad Use this feature to select function key and keypad setting on Putty The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Out of Band Mgmt Port Use this feature to select the port for out of band management The options are COMO and COM1 Serial Port for Out of Band Management Windows Emergency Management Services EMS This item allows the user to configure Console Redirection settings to support Out of Band Serial Port management gt ACPI Settings Use this feature to configure Advanced Configuration and Power Interface ACPI power management settings for your system ACPI Sleep State Use this feature to select the ACPI State when the system is in sleep mode Select 51 CPU Stop Clock to erase all CPU caches and stop executing instructions Power to the CPU s and RAM is maintained but RAM is refreshed Select Suspend to use power reduced mode Power will only be supplied to limited components such as RAMs to maintain the most critical functions of the system The options are 51 CPU Stop Clock and Suspend Disabled Numa This feature enables the Non Uniform Memory Access ACPI support The options are Enabled and Disabled High Preci
93. rket which may mean the assembly procedure will differ slightly The following is a guideline for installing the server into a rack with the rack rails provided in the rackmount kit You should also refer to the installation instructions that came with the rack unit you are using A Warning Do not pick up the server with the front handles They are designed to pull the system from a rack only A Stability Hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Warning When initially installing the server to a rack test that the rail locking tabs engage to prevent the server from being overextended Have a rack lift in place as a precaution in case the test fails Warning In any instance of pulling the system from the rack always use a rack lift and follow all associated safety precautions Identifying the Sections of the Rack Rails The optional rackmount kit includes two rack rail assemblies Each of these assemblies consist of three sections an inner fixed chassis rail that secures to the chassis an outer rack rail that secures directly to the rack itself and two rail brackets which also attack to the rack see Figure 2 1 The inner and outer rails must be detached from each other to install To remove the inner chassis rail pull it out as far as possible you should hear a click s
94. ro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale B 4
95. rst need to uninstall SuperDoctor III Figure 5 8 Supero Doctor Ill Interface Display Screen Health Information SuperDoctor III Remote Management Health Information 5 28 Chapter 5 Advanced Serverboard Setup Figure 5 9 Supero Doctor Ill Interface Display Screen Remote Control SuperDoctor Remote Management Info Health Info Remote Control Graceful power control cancelable Supero Doctor III allows a user to inform the OS to reboot or shut down the system within 30 seconds On the system console a pop up window will appear with a message telling the local user to save his working files Before the system reboots or shuts down it s allowed to cancel the action either locally or remotely Power control noncancelable Supero Doctor III allows a user to inform the OS to reboot or shut down the system right away The system will reboot or shut down without any warning messages It s not allowed to cancel the action il Note The SuperDoctor IIl program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software SuperDoctorlll cfm For Linux we recommend that you use the SuperDoctor II application instead 5 29 SUPERSERVER 7047R TRF USER S MANUAL 5 14 Serverboard Battery Caution There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarites see Fig
96. s Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate WARNING Handling of lead solder materials used in this product may expose you to lead a chemical known to the State of California to cause birth defects and other reproductive harm Manual Revision 1 0b Release Date October 24 2013 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2013 by Super Micro Computer Inc All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for the installation and use of the SuperServer 7047R TRF Installation and maintainance should be performed by experienced technicians only The SuperServer 7047R TRF is a high end server based on the SC745TQ R920B 4U tower rackmountable chassis and the X9DRi F serverboard Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRi F serverboard and the SC745TQ R920B chassis Chapter 2 Server
97. s The options are DRAM RAPL MODEO DRAM RAPL MODE1 and Disabled MPST Support Select Enabled to enable the Message Processing Subscriber Terminal which is used to process short messages The options are Disabled and Enabled DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what the system is specified in the specification The options are Auto Force DDR3 800 Force DDR3 1066 Force DDR3 1333 Force DOR3 1600 and Force SPD Channel Interleaving This feature selects from the different channel interleaving methods The options are Auto 1 Way 2 Way 3 Way and 4 Way Rank Interleaving This feature allows the user to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor the original source When this item is set to Enabled the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enabled and Disabled Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory tur
98. s to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when you pull it out for servicing Figure 2 2 Preparing to Install the Chassis Rails Chapter 2 Server Installation Installing the Rack Rails Determine where you want to place the SuperServer 7047R TRF in the rack See Rack and Server Precautions in Section 2 3 Position the fixed rack rail sliding rail guide assemblies at the desired location in the rack keeping the sliding rail guide facing the inside of the rack Screw the assembly securely to the rack using the brackets provided Attach the other assembly to the other side of the rack making sure both are at the exact same height and with the rail guides facing inward Figure 2 3 Installing the Rails to the Chassis o SUPERSERVER 7047R TRF USER S MANUAL Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit The next step is to install the server into the rack You should have two brackets in the rack mount kit Install these first keeping in mind that they are left right specific marked with L and R Then line up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even
99. should be in decimal and in dotted quad form e 192 168 10 253 Router MAC Address This item displays the Router Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers 7 6 Boot Boot Option Priorities Boot Option 1 Boot Option 2 Boot Option 3 Use this feature to specify the sequence of boot device priority Network Device BBS Priorities Hard Drive BBS Priorities This option sets the order of the legacy network devices and Hard Disks detected by the motherboard Delete Boot Option This feature allows the user to delete a previously defined boot device from which the system boots during startup Boot Option 1 Boot option 2 Boot Option 3 The settings are Built in EFI Shell and any pre defined boot device 7 7 Security This menu allows the user to configure the following security settings for the system Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 8 characters long User Password Use this feature to set a User Password which is required to log into the system and to enter the BIOS setup utility The length of the password should be from 3 characters to 8 characters long 7 25 SUPERSERVER 7047R TRF USER S MANUAL 7 8 Save amp Exit This menu allows the user to configure the Save and Exit settings for the system Discard Changes an
100. sion Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback reducing the de pendency on other timestamp calculation devices such as an x86 RDTSC Instruc 7 20 Chapter 7 BIOS tion embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The options are Enabled and Disabled gt Trusted Computing Available if TPM device is installed Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherboard to allow TPM support to improve data integrity and network security The options are Enabled and Disabled Current Status Information This item displays the information regarding the current TPM status TPM Enable Status This item displays the status of TPM Support to indicate if TPM is currently enabled or disabled TPM Active Status This item displays the status of TPM Support to indicate if TPM is currently active or deactivated TPM Owner Status This item displays the status of TPM Ownership Intel TXT LT SX Configuration Intel TXT Trusted Execution Technology helps protect against software based attacks and ensures protection confidentiality and integrity of data stored or created on the system 7 21 SUPERSERVER 7047R TRF USER S MANUAL gt
101. sposal A Warning Ultimate disposal of this product should be handled according to all national laws and regulations Sh o Bese COSI Ze BERL TIDA IH BO UR SA CO TET LES S HIVES Tt BEAL E AST RFP Me ARE A EAL e ET o uj IE p EE ARPT BR EA HET Hn 4 15 SUPERSERVER 7047R TRF USER S MANUAL Warnung Die Entsorgung dieses Produkts sollte gem t allen Bestimmungen und Gesetzen des Landes erfolgen jAdvertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis a des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent pi LITTIN ny3nn sp nvmi m ax 70 530 p170 Ae gl cil gll y gill apal Ane Soleil giall alil aie Kb qe apu tal dt ub spen el 7 By ch Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen Hot Swap Fan Warning A Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing E E
102. support for Port 3A Select GEN2 to enable PCI Exp Generation 2 support for Port 3A Select GENS to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GEN3 Port 3C Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3C Select GEN2 to enable PCI Exp Generation 2 support for Port 3C Select GENS to enable PCI Exp Generation 3 support for Port 3C The options are GEN1 GEN2 and GEN3 IOH 1 PCle Port Bifuracation Control This submenu allows the user to configure the following 6 PCle Port Bifurcation Control settings for the IOH 1 PCI Exp port This feature determines how to distribute the available PCI Express lanes to the PCI E Root Ports IOU1 PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU1 and PCl e port The options are x4x4 and x8 7 9 SUPERSERVER 7047R TRF USER S MANUAL Port 1A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1A Select GEN2 to enable PCI Exp Generation 2 support for Port 1A Select GEN3 to enable PCI Exp Generation 3 support for Port 1A The options are GEN1 GEN2 and GENS IOU2 PCle Port This feature allows the user to set the PCI Exp bus speed between IOU2 and PCle port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 2A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 2A Select GEN2 to enable PCI Exp Generation 2 support for Port 2A Select GE
103. support team at support supermicor com 1 1 SUPERSERVER 7047R TRF USER S MANUAL 1 2 Serverboard Features At the heart of the SuperServer 7047R TRF lies the X9DRi F a dual processor serverboard based on the Intel PCH C602 C606 chipset Below are the main features of the X9DRi F See Figure 1 1 for a block diagram of the chipset Processors The X9DRi F supports single or dual E5 2600 V2 series processors in Socket R LGA2011 type sockets Please refer to our web site for a complete listing of supported processors www supermicro com Note If only one CPU is installed then only half the PCI E slots PCI E 1 3 will function in the server The system needs both CPUs installed for all PCI E slots to funtion Memory The X9DRi F has 16 single dual tri quad channel 240 pin DIMM sockets that can support up to 512 GB of DDR3 1866 1600 1333 1066 800 MHz registered ECC SDRAM in two channel memory bus Memory sizes of 1GB 2GB 4GB 8GB 16GB and 32GB 1 35V 1 5V voltages are supported Please refer to Chapter 5 for installing memory Serial ATA An on chip PCH C606 SATA controller is integrated into theX9DRi F to provide a six port 3 Gb sec SATA subsystem which is RAID 0 1 5 and 10 supported The SATA drives are hot swappable units Note You must have RAID set up to enable the hot swap capability of the SATA drives Documentation on RAID setup guidelines can be found on our web site Onboard Controllers Ports The color
104. te event must happen before the MECI counter is incremented This is a numeric value ranging from 1 to 255 METW The Multiple Event Time Window METW defines number of minutes must pass between duplicate log events before is incremented This is in minutes from 0 to 99 View Smbios Event Log This feature displays the contents of the SmBIOS Event Log View System Event Log This feature displays the contents of the System Event Log 7 5 IPMI P System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes On every reset 7 23 SUPERSERVER 7047R TRF USER S MANUAL When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full Select Erase Immediately to erase all events in the log when the system event log is full The options are Do Nothing and Erase Immediately Cstom EFI Logging Options Log EFI Status Codes Select Enabled to log EFI Extensible Firmware Interface Status Codes Error Codes or Progress Codes The options are Disabled and Enabled
105. the CPU Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web Sites for more information Hardware Prefetcher Available when supported by the CPU If set to Enabled the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance The options are Disabled and Enabled Adjacent Cache Line Prefetch Available when supported by the CPU If this feature is set to Disabled The CPU prefetches the cache line for 64 bytes If this feature is set to Enabled the CPU fetches both cache lines for 128 bytes as comprised The options are Disabled and Enabled DCU Streamer Prefetcher Available when supported by the CPU Select Enabled to support Data Cache Unite DCU prefetch to speed up data accessing and processing in the DCU to enhance CPU performance The options are Disabled and Enabled DCU IP Prefetcher Select Enabled for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enabled and Disabled Intel amp Virtualization Technology Available when supported by the CP
106. the CPU inside the socket Lock the lever labeled Close 1st first then lock the lever labeled Open 1st second Use your thumb to gently push the load levers down to the lever locks Gently close the load plate Push down and lock the level labeled Close 1st Push down and lock the lever labeled Open 1st Lever Lock 5 5 SUPERSERVER 7047R TRF USER S MANUAL Installing a Passive CPU Heatsink 1 Do not apply any thermal grease to the heatsink or the CPU die the required amount has already been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the CPU 4 Finish the installation by fully tightening all four screws Screw 1 ES Motherboard Chapter 5 Advanced Serverboard Setup Removing the Heatsink Warning We do not recommend that the CPU or the heatsink be removed However if you do need to uninstall the heatsink please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket 1 Unscrew the heatsink screws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when
107. the bay and secure it to the chassis with the drive carrier screws you first removed 3 Attach the power and data cables to the drive 4 Replace the top left chassis cover before restoring power to the system 6 7 SUPERSERVER 7047R TRF USER S MANUAL Storage Module If the SuperServer 7047R TRF is to be used in a rack configuration you must turn the storage module 90 degrees This can be done before during or after setup Rotating the Storage Module 1 2 o o B oO Storage Module Open the chassis cover Disconnect any cables from the storage module to any components in the chassis Push the storage module release lever to unlock the storage module Grasp the external edges of the storage module and pull it from the chassis Turn the storage module 90 degrees as illustrated Reinsert the module into the chassis and reconnect the cords Figure 6 7 Rotating the Storage Module Storage Module Release Lever 6 8 Chapter 6 Advanced Chassis Setup 6 5 Power Supply The SuperServer 7047R TRF has two 920 Watt power supply modules The power supply has an auto switching capability which enables it to automatically sense and operate at a 100V 240V input voltage With redundant power the system does not need to be shut down when replacing a failed power supply module follow the procedure below but skip the steps on removing power Power Supply Failure If the power supply unit fails
108. the system will shut down and you will need to replace the power supply unit Replace with the same model which can be ordered directly from Supermicro see Contact Information in the Preface As there is only one power supply unit the system must be powered down before removing and or replacing the power supply for whatever reason Replacing the Power Supply 1 First power down the system 2 Unplug the AC power cord from the power supply module 3 Remove the screws that secure the module to the chassis then pull it completely out 4 Replace the failed unit with another unit of the exact same part number see Appendix 5 Gently but firmly push the new unit all the way into the open bay 6 Secure it to the chassis using the screws you previously removed 7 Finish by replacing the chassis left top cover and then plugging the AC power cord back into the new module you just added 8 Push the power button to restart the system 6 9 SUPERSERVER 7047R TRF USER S MANUAL Notes Chapter 7 BIOS 7 1 Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the SUPERSERVER 7047R TRF The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens Starting the Setup Utility To enter the BIOS Setup Utility hit the lt Delete gt key while the system is booting up In most cases the lt
109. tion is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button PW_ON 2 Ground can also be configured to function as a suspend button with a setting in the BIOS See Chapter 5 To turn off the power when the system is in suspend mode press the button for 4 seconds or longer Refer to the table on the right for pin definitions 5 16 Reset Connector The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis See the table on the right for pin definitions Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1 Refer to the table on the right for pin definitions Overheat Fan Fail LED OH Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure Refer to the table on the right for pin definitions and status indicators NIC2 LAN2 LED The LED connections for LAN2 are on pins 9 and 10 of JF1 Attach LAN LED cables to display network activity See the table on the right for pin definitions NIC1 LAN1 LED The LED connections for LAN1 are on pins 11 and 12 of JF1 Attach LAN LED cables to display network activity See the table on the right for pin definitions 5 17 Chapter 5 Advanced Serverboard Setup Reset Button Pin Definitions JF1 Pin Definition 3 Res
110. ttings for the IOH 0 PCI Exp port This feature determines how to distribute the available PCI Express lanes to the PCI E Root Ports IOU1 PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU1 and PCl e port The options are x4x4 and x8 Port 1A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1A Select GEN2 to enable PCI Exp Generation 2 support for Port 1A Select GENS to enable PCI Exp Generation 3 support for Port 1A The options are GEN1 GEN2 and GEN3 7 8 Chapter 7 BIOS Port 1B Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1B Select GEN2 to enable PCI Exp Generation 2 support for Port 1B Select GEN3 to enable PCI Exp Generation 3 support for Port 1B The options are GEN1 GEN2 and GENS IOU2 PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU2 and PCle port The options are xAx4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 2A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 2A Select GEN2 to enable PCI Exp Generation 2 support for Port 2A Select GENS to enable PCI Exp Generation 3 support for Port 2A The options are GEN1 GEN2 and GEN3 IOUS PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU3 and PCle port The options are xAx4x4x4 xAx4x8 x8x4x4 x8x8 and x16 and Auto Port 3A Link Speed Select GEN1 to enable PCI Exp Generation 1
111. ure 5 x This battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 10 Installing the Onboard Battery BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly 5 30 Chapter 6 Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform simple maintenance on the SC745TQ R920B chassis Following the component installation steps in the order given will eliminate most common problems If some steps are unnecessary skip ahead to the step that follows Refer to Chapter 2 for instructions on installing the system as a 4U rackmount Tools Required The only tool you will need is a Philips screwdriver 6 1 Static Sensitive Devices Static electrical discharge can damage electronic components To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from static discharge Precautions e Use a grounded wrist stra