Home
Sun Storage 2500-M2 Arrays
Contents
1. When a SLES 11 1 host with smartd monitoring enabled is mapped to volumes on either a Sun Storage 2500 M2 or 6780 array it is possible to receive IO FAILURE and Illegal Request ASC ASCQ log events Workaround Either disable smartd monitoring or disregard the messages This is an issue with the host OS Cluster Startup Fails When Devices Are in a Unit Attention State Configuration m Red Hat Enterprise Linux RHEL version 6 0 with Native Cluster m Device Mapper Multipath DMMP failover driver Problem or Restriction This problem occurs when the DMMP failover driver is used with the RHEL version 6 0 OS If you try to set up a Red Hat cluster with the DMMP failover driver cluster startup might fail during the unfencing stage where each host registers itself with the SCSI devices The devices are in a Unit Attention state which causes the SCSI registration command issued by the host during startup to fail When the cluster manager cman service starts the logs show that the nodes failed to unfence themselves which causes the cluster startup to fail Workaround To avoid this problem do not use the DMMP failover driver with RHEL version 6 0 To recover from this problem open a terminal window and run sg turs n 5 device where device is a SCSI device that is virtualized by the DMMP failover driver Run this command on every dev sd device that the DMMP failover driver manages It issues a Test Unit Ready comman
2. This software or hardware and documentation may provide access to or information on content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with resped to third party content products and services Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services Copyright 2011 2012 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui accompagne sont pes par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le logiciel m me partiellement sous quelque forme et par quelque roc d que ce soit Par ailleurs il est interdit de proc der toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except a es fins d interop rabilit avec des logiciels tiers ou tel que prescrit par la loi Les informations fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient exemptes d erreurs et vous invite
3. go to Step 6 a If the correct level of the multipath tools is not installed install the correct level of the multipath tools or update the existing multipath tools Then go to Step 6 6 Update the configuration file etc multipath conf See Setting Up the multipath conf File on page 15 for detailed information about the etc multipath conf file 7 On the command line enter chkconfig multipathd on This command enables multipathd daemon when the system boots 8 Edit the etc sysconfig kernel file to add directive scsi dh rdac to the INITRD MODULES section of the file 9 Download the KMP package for scsi dh rdac for the SLES 11 architecture from the website http forgeftp novell com driver process staging pub update 1si sle11 common and install the package on the host 10 Update the boot loader to point to the new initrd image and reboot the host with the new initrd image Setting Up the multipath conf File The multipath conf file is the configuration file for the multipath daemon multipathd The multipath conf file overwrites the built in configuration table for multipathd Any line in the file whose first non white space character is is considered a comment line Empty lines are ignored Installing the Device Mapper Multi Path for SLES 11 1 All of the components required for DMMP are included in SUSE Linux Enterprise Server SLES version 11 1 installation media However users might need to select th
4. XPCIE2FCGBE E Z 8 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 TABLE 6 Supported Fibre Channel HBAs for Linux Data Host Platforms Host OS Generic HBAs Oracle 2 Gbit HBAs Oracle 4 Gbit HBAs Oracle 8 Gbit HBAs Oracle Linux 5 5 5 6 6 0 RHEL 5 5 5 6 6 0 Oracle VM 2 2 2 SLES SG XPCIE1FC QF8 Z 10 1 10 4 11 11 1 QLogic QLE 256x QLE 246x QLA 246x QLA 234x QLA 2310F Emulex LP982 LP9802 9802DC LP9002 LP9002DC LP952 LP10000 10000DC LP1050 Lpe11000 LPe11002 LPe1150 Lpe12000 LPe12002 LPe1250 OLogic OLE 256x OLE246x QLA 246x QLA 234x QLA 2310F Emulex LP982 LP9802 9802DC LP9002 LP9002DC LP952 LP10000 10000DC LP1050 LP11000 LP11002 LP1150 Lpe11000 LPe11002 LPe1150 Lpe12000 LPe12002 Lpe1250 SG XPCI1FC EM2 SG XPCI2FC EM2 SG XPCIIFC OL2 SG XPCI2FC QF2 Z SG XPCIIFC EM2 SG XPCDFC EM2 SG XPCIIFC OL2 SG XPCI2FC QF2 Z SG XPCIE1FC OF4 SG XPCIE2FC OF4 SG XPCIE1FC EM4 SG XPCIE2FC EM4 SG XPCI1FC QF4 SG XPCI2FC QF4 SG XPCI1FC EM4 Z SG XPCI2FC EM4 Z SG XPCIE2FCGBE O Z SG XPCIE2FCGBE E Z SG XPCIE1FC OF4 SG XPCIE2FC OF4 SG XPCIE1FC EM4 SG XPCIE2FC EM4 SG XPCI1FC QF4 SG XPCDFC OF4 SG XPCI1FC EM4 SG XPCI2FC EM4 SG XPCIE2FCGBE O Z SG XPCIE2FCGBE E Z SG XPCIE1FC QF8 Z SG XPCIE2FC OF8 Z SG XPCIE1FC EM8 Z SG XPCIE2FC EM8 Z SG XPCIEFCGBE Q8 SG XPCIEFCGBE E8 SG XPCIE2FC QF8 Z SG XPCIE1FC EM8 Z SG XPCIE2FC EM8 Z SG XPCIEF
5. and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications which may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure its safe use Oracle orporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc UNIX is a registered trademark licensed through X Open Company Ltd
6. le cas ch ant a lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas concu ni n est destin tre utilis dans des applications risque notamment dans des applications pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est de votre responsabilit de prendre toutes le
7. section blacklist m devices Lists all multipath devices with their matching vendor and product values m multipaths Lists the multipath device with their matching WWID values Determine the Attributes of a MultiPath Device To determine the attributes of a multipath device check the multipaths section of the etc multipath conf file then the devices section then the defaults section The model settings used for multipath devices are listed for each storage array and include matching vendor and product values Add matching storage vendor and product values for each type of volume used in your storage array For each UTM LUN mapped to the host include an entry in the blacklist section of the etc multipath conf file The entries should follow the pattern of the following example 16 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 blacklist device vendor product Universal Xport The following examples show the devices section from the etc multipath conf file Be sure the vendor ID and the product ID for the Sun Storage 2500 M2 arrays are set as shown in the following examples For 2530 M2 devices device vendor product path_grouping_policy prio getuid_callout polling_interval path_checker path_selector hardware_handler failback immediate features no_path_retry rr_min_io For 2540 M2 devices device vendor product path_grouping_policy prio getuid_callout polling_i
8. supports concatenation striping snapshots mirroring and multipathing The multipath function is provided by the combination of the kernel modules and user space tools The DMMP is supported on SUSE Linux Enterprise Server SLES Version 11 and 11 1 The SLES installation must have components at or above the version levels shown in the following table before you install the DMMP TABLE 11 Minimum Supported Configurations for the SLES 11 Operating System Version Component Kernel version kernel default 2 6 27 29 0 1 1 Scsi dh rdac kmp lsi scsi dh rdac kmp default 0 0 2 6 27 19 5 1 Device Mapper library device mapper 1 02 27 8 6 Multipath tools multipath tools 0 4 8 40 6 1 To update a component download the appropriate package from the Novell website athttp download novell com patch finder The Novell publication SUSE Linux Enterprise Server 11 Installation and Administration Guide describes how to install and upgrade the operating system Device Mapper Features m Provides a single block device node for a multipathed logical unit m Ensures that I O is re routed to available paths during a path failure m Ensures that the failed paths are revalidated as soon as possible m Configures the multipaths to maximize performance m Reconfigures the multipaths automatically when events occur m Provides DMMP features support to newly added logical unit m Provides device name persistency for DMMP devices under dev mapper
9. use for handling device specific knowledge failback 10 A parameter to tell the daemon how to manage path group failback In this example the parameter is set to 10 seconds so failback occurs 10 seconds after a device comes online To disable the failback set this parameter to manual Set it to immediate to force failback to occur immediately 18 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 TABLE 12 Attributes and Values in the multipath conf File Continued Attribute Parameter Value Description features 2 Features to be enabled This parameter pg_init_retries sets the kernel parameter 50 pg_init_retries to 50 The pg_init_retries parameter is used to retry the mode select commands no_path_retry 30 Specify the number of retries before queuing is disabled Set this parameter to fail for immediate failure no queuing When this parameter is set to queue queuing continues indefinitely rr_min_io 100 The number of I Os to route to a path before switching to the next path in the same path group This setting applies if there is more than one path in a path group Using the Device Mapper Devices Multipath devices are created under dev directory with the prefix dm These devices are the same as any other bock devices on the host To list all of the multipath devices run the multipath 11 command The following example shows system output from the multipath 11 command for one of the multi
10. with proper settings 20 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Restrictions and Known Issues The following are restrictions and known issues applicable to this product release m Restrictions on page 21 m Controller Issues on page 22 m OS Issues on page 23 Restrictions Single Path Data Connections In a single path data connection a group of heterogeneous servers is connected to an array through a single connection Although this connection is technically possible there is no redundancy and a connection failure will result in loss of access to the array Caution Because of the single point of failure single path data connections are not recommended SAS Host Ports on the Sun Storage 2540 M2 Although SAS host ports are physically present on the Sun Storage 2540 M2 array controller tray they are not for use not supported and are capped at the factory FIGURE 1 shows the location of these ports The Sun Storage 2540 M2 only supports Fibre Channel host connectivity FIGURE1 SAS Host Ports on the 2540 M2 2540 M2 Sun Storage 2500 M2 Arrays Hardware Release Notes 21 SAS 2 Phase 5 HBA Unable to Boot from Attached 2530 M2 Volume Bug 7042226 SAS 2 HBA device booting is not supported using Phase 5 HBA firmware This restriction will be lifted with the Phase 10 HBA firmware Controller Issues 1 0 Errors Occur During Contro
11. 2002 LPe1250 Lpe11000 LPe11002 LPe1150 LP11000 LP11002 LP1150 LP9802 9802DC 982 LP952 LP9002 LP9002DC 10000 10000DC LP1050 10 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 TABLE7 Supported Fibre Channel HBAs for Windows Data Host Platforms Continued Host OS E Servers Generic HBAs Sun 2 Gb HBAs Sun 4 Gb HBAs Sun 8 Gb HBAs Microsoft QLogic SG XPCHFC EM2 SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z Windows QLE 256x SG XPCDFC EM2 SG XPCIE2FC QF4 SG XPCIE2FC QF8 Z 2008 QLE 246x SG XPCHFC QL2 SG XPCIEIFC EM4 SG XPCIE1FC EM8 Z 64bitwith OLA 246x SG XPCI2FC QF2 Z SG XPCIE2FC EM4 SG XPCIE2FC EM8 Z F R2 GLA 234x SG XPCI1FC QF4 SG XPCIEFCGBE Q8 AMD QLA 2310F SG XPCI2FC QF4 SG XPCIEFCGBE E8 EM64T Emulex SG XPCI1FC EM4 IA64 LPe12000 LPe12002 LPe1250 SG XPCI2FC EM4 Lpe11000 LPe11002 LPe1150 SG XPCIE2FCGBE Q Z LP11000 LP11002 LP1150 SG XPCIE2FCGBE E Z LP9802 9802DC 982 LP952 LP9002 LP9002DC 10000 10000DC LP1050 For generic HBA support contact the HBA manufacturer TABLE8 Supported SAS HBAs for Solaris and Linux Data Host Platforms Host OS Oracle 3 Gbit HBAs SAS 1 Oracle 6 Gbit HBAs SAS 2 t Solaris 10u9 minimum SG XPCIE8SAS E Z SG X SAS6 EXT Z Oracle Linux 5 5 SG XPCIE8SAS EB Z SG X SAS6 EM Z RHEL 5 5 See SAS 1 HBA Settings on page 12 t See Restrictions on page 21 TABLE9 Supported SAS HBAs for Microsoft Windows Data Host Platforms Host OS Oracle 3 Gbit HBAs SAS 1 Oracle
12. 3 and TABLE 4 provide a summary of the data host requirements for the Sun Storage 2500 M2 Arrays You must install multipathing software on each data host that communicates with the Sun Storage 2500 M2 Arrays For additional information on multipathing software see the following m Sun StorageTek RDAC Multipath Failover Driver Installation Guide For Linux OS m Device Mapper Multipath DMMP for the Linux Operating System on page 13 Note Download RDAC multipathing drivers from My Oracle Support at https support oracle com using keyword RDAC or MPP See Downloading Patches and Updates on page 3 for more information Note Single path data connections are not recommended For more information see Single Path Data Connections on page 21 TABLE3 Supported Fibre Channel Multipathing Software Multipathing os Software Minimum Version Host Type Setting Notes Solaris 10 STMS MPxIO Update 5 Solaris with Multipathing software MPxIO included in Solaris OS 10 Oracle Linux 6 0 5 6 5 5 RDAC 09 03 0C02 0453 Linux Unbreakable Linux DMMP Unbreakable Multipathing software included in OS Oracle VM 2 2 2 RDAC RDAC version Linux 09 03 0C02 0331 is included with Oracle VM 2 2 2 RHEL 6 0 5 6 5 5 RDAC 09 03 0C02 0453 Linux SLES 10 4 10 SP3 RDAC MPP 09 03 0C02 0453 Linux 6 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 TABLE3 Supported Fibre Channel Multipathing Software Continued M
13. 6 Gbit HBAs SAS 2 Windows 2008 SG XPCIE8SAS E Zt SG X SAS6 EXT Zt Windows 2008 R2 Windows 2003 SP2 Notsupported with SAS 2 HBAs t With firmware 1 30 04 00 phase 17 See http www 1si com sep Pages oracle sg xpci8sas e sRoHS aspx t With firmware 2 00 29 00 phase 5 See http www 1si com sep Pages oracle sg x sas6 int ext em z aspx Sun Storage 2500 M2 Arrays Hardware Release Notes 11 SAS 1 HBA Settings TABLE 10 lists supported HBA settings for SAS 1 HBA compatibility Configuration Firmware 01 29 06 00 IT with NVDATA 2DC5 BIOS 6 28 00 00 FCode 1 00 49 TABLE 10 SAS 1 HBA Settings Host OS Settings Solaris 10u9 SPARC HBA defaults Solaris 10u9 x86 IODeviceMissingDelay 20 ReportDeviceMissingDelay 20 Oracle Linux 5 5 IODeviceMissingDelay 8 RHEL 5 5 ReportDeviceMissingDelay 144 Supported FC and Multilayer Switches The following FC fabric and multilayer switches are compatible for connecting data hosts and the Sun Storage 2540 M2 array See the release notes for your switch hardware for firmware support information m Brocade SilkWorm 200E 300 4100 4900 5000 5100 5300 7500 48000 DCX m Cisco 9124 9134 9216 92161 92221 9506 9509 9513 m OLogic SANBox 5602 9000 12 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Device Mapper Multipath DMMP for the Linux Operating System Device Mapper DM is a generic framework for block devices provided by the Linux operating system It
14. 74 01 c Click Search If you do not have a patch number a Under the Patch Search section click the Search tab and then click the Product or Family Advanced Search link b Check Include all products in a family c In the Product field start typing the product name For example Sun Storage Common Array Manager CAM Select the product name when it appears d In the Release field expand the product name check the release and patches you want to download and then click Close e Click Search Select the patch you want to download Click ReadMe for a patch description and installation instructions Click Download for a single patch or Add to Plan to download a group of patches System Requirements The software and hardware products that have been tested and qualified to work with Sun Storage 2500 M2 Arrays are described in the following sections Sun Storage 2500 M2 Arrays require Sun Storage Common Array Manager Version 6 8 0 or higher software Firmware Requirements on page 5 Supported Disk Drives and Tray Capacity on page 5 Array Expansion Module Support on page 5 Data Host Requirements on page 6 4 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Firmware Requirements The Sun Storage 2500 M2 Arrays firmware version 07 80 xx xx or higher is installed on the array controllers prior to shipment and is also delivered with Sun Storage Common Ar
15. CGBE E8 SG XPCIEFCGBE Q8 For generic HBA support contact the HBA manufacturer Sun Storage 2500 M2 Arrays Hardware Release Notes 9 Sun 2 Gb HBAs Supported Fibre Channel HBAs for Windows Data Host Platforms Sun 4 Gb HBAs Sun 8 Gb HBAs SG XPCIIFC EM2 SG XPCDFC EM2 SG XPCI1FC QL2 SG XPCI2FC QF2 Z SG XPCIE1FC QF4 SG XPCIE2FC QF4 SG XPCIE1FC EM4 SG XPCIE2FC EM4 SG XPCI1FC QF4 SG XPCDFC OF4 SG XPCITIFC EMA SG XPCI2FC EM4 SG XPCIE2FCGBE O Z SG XPCIE2FCGBE E Z SG XPCIE1FC QF8 Z SG XPCIE2FC OF8 Z SG XPCIE1FC EM8 Z SG XPCIE2FC EM8 Z SG XPCIEFCGBE Q8 SG XPCIEFCGBE E8 SG XPCIIFC EM2 SG XPCDFC EM2 SG XPCI1FC QL2 SG XPCI2FC QF2 Z SG XPCIE1FC QF4 SG XPCIE2FC QF4 SG XPCIE1FC EM4 SG XPCIE2FC EM4 SG XPCI1FC QF4 SG XPCI2FC QF4 SG XPCIIFC EMA SG XPCI2FC EM4 SG XPCIE2FCGBE O Z SG XPCIE2FCGBE E Z SG XPCIE1FC QF8 Z SG XPCIE2FC QF8 Z SG XPCIE1FC EM8 Z SG XPCIE2FC EM8 Z SG XPCIEFCGBE E8 SG XPCIEFCGBE Q8 TABLE 7 Host OS Servers Generic HBAs Microsoft QLogic Windows QLE 256x up QLE 246x erver 32 bit x86 QLA 246x IA32 QLA 234x 7 QLA 2310F 64 bit Q x64 Emulex AMD LPe12000 LPe12002 EM64T LPe1250 IA64 Lpe11000 LPe11002 LPe1150 LP11000 LP11002 LP1150 LP9802 9802DC 982 LP952 LP9002 LP9002DC 10000 10000DC LP1050 Microsoft QLogic Windows QLE 256x 2003 QLE 246x 32 bit with QLA 246x SP2 R2 LA x86 1A32 QLA 234x QLA 2310F Emulex LPe12000 LPe1
16. Configuration m Red Hat Enterprise Linux RHEL or Oracle Linux version 5 5 or 5 6 m RDAC driver version 09 03 0C02 0453 Bug 7042297 Before running a make on the RDAC driver the following kernel packages are required m kernel 2 6 18 194 el5 m kernel devel 2 6 18 194 e15 x86 64 rpm m kernel headers 2 6 18 194 e15 x86 64 rpm m glibc headers 2 5 49 x86_64 rpm m glibc devel 2 5 49 x86 64 rpm m libgomp 4 4 0 6 e15 x86 64 rpm m gcc 4 1 2 48 e15 x86 64 rpm RHEL6 DMMP Excessive Log Messages Bug 7034078 When booting a Red Hat Enterprise Linux 6 0 host mapped to volumes on a Sun Storage 2500 M2 array in a multipath configuration using DMMP it is possible to receive excessive messages similar to the following m multipathd dm 2 add map uevent m multipathd dm 2 devmap already registered Workaround This is normal behavior on RHEL 6 0 Sun Storage 2500 M2 Arrays Hardware Release Notes 23 Oracle Linux 6 Boots With Messages Bugs 7038184 7028670 7028672 When booting an Oracle Linux 6 0 host mapped to volumes on Sun Storage 2500 M2 and 6780 arrays it is possible to receive one of these messages FIXME driver has no support for subenclosures 1 FIXME driver has no support for subenclosures 3 Failed to bind enclosure 19 Workaround This is a cosmetic issue with no impact to the I O path There is no workaround Log Events Using SLES 11 1 With smartd Monitoring Enabled Bug 7014293
17. Sun Storage 2500 M2 Arrays Hardware Release Notes Release 6 9 x S amp Sun Part No E24025 02 ep PJE February 2012 Copyright 2011 2012 Oracle and or its affiliates All rights reserved This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related software documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government the following notice is applicable U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such the use duplication disclosure modification
18. ce discovery might occur and the syslog might get populated with buffer I O error messages If the storage vendor and model are not included in scsi_dh_rdac device handler slower device discovery might be seen and the syslog might get populated with buffer I O error messages Use of the DMMP and RDAC failover solutions together on the same host is not supported Use only one solution at a time Installing the Device Mapper Multi Path 1 2 Use the media supplied by your operating system vendor to install SLES 11 Install the errata kernel 2 6 27 29 0 1 Refer to the SUSE Linux Enterprise Server 11 Installation and Administration Guide for the installation procedure To boot up to 2 6 27 29 0 1 kernel reboot your system On the command line enter rpm qa grep device mapper and check the system output to see if the correct level of the device mapper component is installed a If the correct level of the device mapper component is installed Go to Step 5 14 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 a If the correct level of the device mapper component is not installed install the correct level of the device mapper component or update the existing component Then go to Step 5 5 On the command line enter rpm qa grep multipath tools and check the system output to see if the correct level of the multipath tools is installed m If the correct level of the multipath tools is installed
19. d to clear the Unit Attention state and allow node registration on the device to succeed 24 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Node Unfencing Fails when Automatically Generated Host Keys Are Used during a Red Hat Cluster Suite Services Startup Operating System Red Hat Enterprise Linux 6 with Native Cluster Problem or Restriction This problem occurs the first time a cluster is set up when the cluster conf file does not have manually defined host keys When the cluster conf file was first defined to set up a cluster with SCSI reservation fencing the cluster services were started on the nodes With SCSI reservation fencing the hosts try to generate and register a key on the clustered devices as part of the cluster manager s startup The cluster manager service cman fails to start and the key cannot be zero error message appears in the host log Workaround To avoid this problem use only power fencing Do not use SCSI reservation fencing To recover from this problem change to manually defined host keys and restart the cluster services Red Hat Cluster Suite Services with GFS2 Mounts Cannot Transfer Between Nodes when the Client Mounts with NFSv4 Operating System Red Hat Enterprise Linux 6 Native Cluster Problem or Restriction This problem occurs during an attempt to transfer a cluster service manually when a client is connected using NFSv4 The Global File System GFS 2 mount points failed to unmou
20. e VM 2 2 2 2540 M2 only a RedHat Linux 6 0 5 6 5 5 2530 M2 and 2540 M2 m SuSe Linux 11 1 10 4 10 SP3 a Windows 2003 SP2 R2 clustered and non clustered a Windows Server 2008 R2 SP1 clustered and non clustered m Sun Storage Common Array Manager enhancements as described in the CAM Release Notes Product Overview The Sun Storage 2500 M2 Arrays are a family of storage products that provide high capacity high reliability storage in a compact configuration The controller tray with two controller modules provides the interface between a data host and the disk drives Three array models are offered m The Sun Storage 2540 M2 array provides a Fibre Channel FC connection between the data host and the controller tray at 8 Gbit sec m The Sun Storage 2530 M2 array provides a Serial Attached SCSI SAS connection between the data host and the controller tray at 6 Gbit sec Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 m The Sun Storage 2501 M2 array expansion tray provides additional storage via SAS interface at 6 Gbit sec It is connected to either of the above controller tray models The Sun Storage 2500 M2 Arrays are modular and rack mountable in industry standard cabinets The arrays are scalable from a single controller tray configuration to a maximum configuration of one controller tray and three expansion trays The maximum configuration creates a storage array configuration with a total of 48 drives at
21. e specific component based on the storage hardware type By default DMMP is disabled in SLES You must follow the following steps to enable DMMP components on the host Sun Storage 2500 M2 Arrays Hardware Release Notes 15 1 On the command line type chkconfig multipath on The multipathd daemon is enabled with the system starts again 2 Edit the etc sysconfig kernel file to add the directive scsi_dh_rdac to the INITRD_MODULES section of the file 3 Create a new initrd image using the following command to include scsi_dh_rdac into ram disk mkinitrd i boot initrd r rdac k bootvmlinuz 4 Update the boot leader to point to the new initrd image and reboot the host with the new initrd image Copy and Rename the Sample File Copy and rename the sample file located at usr share doc packages multipath tools multipath conf synthetic to etc multipath conf Configuration changes are now accomplished by editing the new etc multipath conf file All entries for multipath devices are commented out initially The configuration file is divided into five sections m defaults Specifies all default values m blacklist All devices are blacklisted for new installations The default blacklist is listed in the commented out section of the etc multipath conf file Blacklist the device mapper multipath by WWID if you do not want to use this functionality m blacklist exceptions Specifies any exceptions to the items specified in the
22. ety Information for Sun Hardware Systems Sun Storage Common Array Manager Release Notes Sun Storage 2500 M2 Arrays Site Preparation Guide Sun Storage 2500 M2 Arrays Support Rail Installation Guide Sun Storage 2500 M2 Arrays Hardware Installation Guide Sun Storage Common Array Manager Quick Start Guide Sun Storage Common Array Manager Installation and Setup Guide Sun Storage Common Array Manager Array Administration Guide Sun Storage Common Array Manager CLI Guide Sun StorageTek MPIO Device Specific Module Installation Guide For Microsoft Windows OS Sun StorageTek RDAC Multipath Failover Driver Installation Guide For Linux OS Sun Storage 2500 M2 Arrays Hardware Release Notes 27 Documentation Support and Training These web sites provide additional resources m Documentation http www oracle com technetwork indexes documentation index html m Support https support oracle com m Training https education oracle com 28 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012
23. ilisation 5 cx CA Adobe PostScript Sun Storage 2500 M2 Arrays Hardware Release Notes This document contains important release information about Oracle s Sun Storage 2500 M2 Arrays managed by Sun Storage Common Array Manager CAM Version 6 9 0 Read this document so that you are aware of issues or requirements that can affect the installation and operation of the array The release notes consist of the following sections What s New for This Release on page 2 Product Overview on page 2 About the Management Software on page 3 Downloading Patches and Updates on page 3 System Requirements on page 4 Device Mapper Multipath DMMP for the Linux Operating System on page 13 Restrictions and Known Issues on page 21 Related Documentation on page 27 Documentation Support and Training on page 28 What s New for This Release Firmware version 7 80 xx x delivered with CAM 6 9 adds these features to Sun Storage 2500 M2 arrays m Expanded features Support for 96 drives 7 expansion trays Performance Enhancer increases performance of the base controller m Data Services support a Snapshot license up to 128 snapshots per array 8 per volume with Snapshot Rollback Volume Copy license up to 255 per array Storage Domains license up to 32 per array m Data host support for a Oracle Linux 6 0 5 6 5 5 Fibre Channel Oracle Unbreakable Linux a Oracl
24. ller Firmware Download Configuration m Red Hat Enterprise Linux RHEL version 6 with kernel 2 6 32 only m PowerPC m Emulex 10N9824 HBA m Device Mapper Multipath DMMP failover driver m Sun Storage 2500 M2 controller tray m Sun Storage 6180 controller tray Note This problem does not occur in RHEL version 6 0 with kernel 2 6 33 Problem or Restriction An I O error occurs during an online controller firmware upgrade Workaround To avoid this problem quiesce the host I O before the performing controller firmware upgrades To recover from this problem make sure that the host reports that it has optimal paths available to the storage array controllers and then resume I O 2500 M2 Controller Firmware Panics during Firmware Download Configuration m Sun Storage 2500 M2 controller tray m Controller firmware version 7 77 m Environmental services monitor ESM IOM Problem or Restriction This problem occurs when a firmware download to the controller causes the controller to panic and reboot 22 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Workaround Stop all I O to the array before initiating the firmware download Once the download is initiated the controller automatically reboots recovering the system Caution To avoid potential data loss stop all I O to the array before initiating the firmware download OS Issues Linux RDAC 09 03 0C02 0453 Make Install Dependencies
25. m Configures multipaths automatically at an early stage of rebooting to permit the OS to install and reboot on a multipathed logical unit Sun Storage 2500 M2 Arrays Hardware Release Notes 13 Known Limitations and Issues of the Device Mapper When storage is configured with AVT mode delays in device discovery might occur Delays in device discovery might result in long delays when the operating system boots In certain error conditions with no_path_retry or queue_if_no_path feature set applications might hang forever To overcome these conditions you must enter the following command to all the affected multipath devices dmsetup message device 0 fail_if_no_path where device is the multipath device name for example mpath2 do not specify the path An I O hang might occur when a volume is unmapped without first deleting the DM device Note This limitation applies to only the SUSE 11 OS Stale entries might not be noticed in multipath 11 output if the volumes are unmapped or deleted without first deleting the DM device and its underlying paths Note This limitation applies to only the SUSE 11 OS Currently the mode select command is issued synchronously for each LUN With large LUN configurations slower failovers for DM multipath devices might occur if there is any delay in completing of the mode select command Note This limitation applies to only the SUSE 11 OS If the scsi_dh_rdac module is not included in initrd slower devi
26. must be sufficiently stressed that the controller response is more than 30 seconds at which time a command is issued to abort if no response is received The abort will be retried indefinitely even when the abort is successful The application either times out or hangs indefinitely on the read or write that is being aborted The messages file reports the aborts and resets might occur on the LUN the host or the bus Factors effecting controller response include Remote Volume Mirroring the controller state the number of attached hosts and the total throughput Workaround To recover from this problem reset the power on the server 26 Sun Storage 2500 M2 Arrays Hardware Release Notes February 2012 Related Documentation Product documentation for Sun Storage 2500 M2 Arrays is available at http www oracle com technetwork documentation oracle unified ss 193371 html Product documentation for Sun Storage Common Array Manager is available at http www oracle com technetwork documentation disk device 194280 html TABLE 15 Related Documentation Application Title Review safety information Review known issues and workarounds Prepare the site Install the support rails Install the array Get started with the management software Install the management software Manage the array Install and configure Multipath failover drivers Sun Storage 2500 M2 Arrays Safety and Compliance Manual Important Saf
27. nt which caused the Red Hat Cluster Suite Services to go to the Failed state The mount point and all other mount points exported from the same virtual IP address becomes inaccessible Workaround To avoid this problem configure the cluster nodes to not allow mount requests from NFS version 4 NFSv4 clients To recover from this problem restart the failed service on the node that previously owned it Host Aborts I O Operations Operating System Red Hat Enterprise Linux version 6 0 Problem or Restriction This problem occurs during an online controller firmware upgrade The controller is not responding quickly enough to a host read or write to satisfy the host After 30 seconds the host sends a command to abort the I O The I O aborts and then starts again successfully Workaround Quiesce the host I O before performing the controller firmware upgrade To recover from this problem either reset the server or wait until the host returns an I O error Sun Storage 2500 M2 Arrays Hardware Release Notes 25 Host Attempts to Abort I O Indefinitely Operating System Red Hat Enterprise Linux version 6 0 with kernel 2 6 32 Red Hat Bugzilla Number 620391 Note This problem does not occur in Red Hat Enterprise Linux version 6 0 with kernel 2 6 33 Problem or Restriction This problem occurs under situations of heavy stress when storage arrays take longer than expected to return the status of a read or write The storage array
28. nterval path_checker path_selector hardware_handler failback immediate features no_path_retry Sun Storage 2500 M2 Arrays Hardware Release Notes SUN LCSM100 S group by prio rdac lib udev scsi id g u 5 rdac round robin 0 1 rdac 2 pg init retries 50 30 100 SUN LCSM100 F group by prio rdac lib udev scsi id g u d dev n 5 rdac round robin 0 1 rdac 2 pg init retries 50 30 d dev n 17 rr_min_io 100 The following table explains the attributes and values in the devices section of the etc multipath conf file TABLE 12 Attributes and Values in the multipath conf File Attribute Parameter Value Description path_grouping_policy group_by_prio The path grouping policy to be applied to this specific vendor and product storage prio rdac The program and arguments to determine the path priority routine The specified routine should return a numeric value specifying the relative priority of this path Higher numbers have a higher priority getuid_callout lib udev The program and arguments to call out Scsi id g u to obtain a unique path identifier d dev n polling interval 5 The interval between two path checks in seconds path checker rdac The method used to determine the state of the path path selector round robin 0 The path selector algorithm to use when there is more than one path in a path group hardware handler 1 rdac The hardware handler to
29. path devices mpathp 3600a0b80005ab177000017544a8d6b92 dm 0 LSI INF 01 00 size 5 0G features 3 queue_if_no_path pg_init_retries 50 hwhandler 1 rdac rw _ round robin 0 prio 6 active _ 5 0 0 0 sdc 8 32 active ready _ round robin 0 prio 1 enabled _ 4 0 0 0 sdb 8 16 active ghost Sun Storage 2500 M2 Arrays Hardware Release Notes 19 In this example the multipath device node for this device is dev mapper mpathp and dev dm 0 The following table lists some basic options and parameters for the multipath command TABLE 13 Options and Parameters for the multipath Command Command Description multipath h Prints usage information multipath 11 Shows the current multipath topology from all available information sysfs the device mapper path checkers and so on multipath f map Flushes the multipath device map specified by the map option if the map is unused multipath F Flushes all unused multipath device maps Troubleshooting the Device Mapper TABLE 14 Troubleshooting the Device Mapper Situation Resolution Is the multipath daemon At the command prompt enter the command multipathd running etc init d multipathd status Why are no devices listed At the command prompt enter the command cat when you run the proc scsi scsi The system output displays all of the multipath 11 devices that are already discovered command Verify that the multipath conf file has been updated
30. pport sun You must install multipathing software before you install any OS patches Download OS updates from the web site of the OS company The following tables list supported HBAs by interface type and operating system TABLE 5 Supported Fibre Channel HBAs for Solaris Data Host Platforms TABLE 6 Supported Fibre Channel HBAs for Linux Data Host Platforms TABLE 7 Supported Fibre Channel HBAs for Windows Data Host Platforms TABLE 8 Supported SAS HBAs for Solaris and Linux Data Host Platforms TABLE 9 Supported SAS HBAs for Microsoft Windows Data Host Platforms TABLE5 Supported Fibre Channel HBAs for Solaris Data Host Platforms Host OS Oracle 2 Gbit HBAs Oracle 4 Gbit HBAs Oracle 8 Gbit HBAs Solaris 10u5 SG XPCI1FC QL2 6767A SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z minimum SG XPCDFC QF2 Z 6768A SG XPCIE2FC OF4 SG XPCIE2FC QF8 Z SPARC SG XPCI1FC EM2 SG XPCIE1FC EM4 SG XPCIE1FC EM8 Z SG XPCDFC EM2 SG XPCIE2FC EMA SG XPCIE2FC EM8 Z SG XPCI1FC QF4 SG XPCIEFCGBE Q8 SG XPCI2FC QF4 SG XPCIEFCGBE E8 SG XPCI1FC EM4 SG XPCI2FC EM4 SG XPCIE2FCGBE O Z SG XPCIE2FCGBE E Z Solaris 10u5 SG XPCI1FC QL2 6767 A SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z minimum SG XPCI2FC QF2 Z 6768A SG XPCIE2FC OF4 SG XPCIE2FC QF8 Z x64 x86 SG XPCI1FC EM2 SG XPCIE1FC EM4 SG XPCIE1FC EM8 Z SG XPCI2FC EM2 SG XPCIE2FC EM4 SG XPCIE2FC EMS8 Z SG XPCI1FC QF4 SG XPCIEFCGBE E8 SG XPCI2FC QF4 SG XPCIEFCGBE Q8 SG XPCI1FC EM4 SG XPCI2FC EM4 SG XPCIE2FCGBE Q Z SG
31. ray Manager CAM Version 6 9 0 Firmware is bundled with the CAM software download package To download CAM follow the procedure in Downloading Patches and Updates on page 3 Supported Disk Drives and Tray Capacity TABLE 1 lists the disk capacity form factor spindle speed interface type interface speed and tray capacity for supported SAS disk drives for the Sun Storage 2500 M2 arrays TABLE1 Supported Disk Drives Drive Description SAS 2 300G15K 300 Gbyte 3 5 15K RPM SAS 2 drives 6 Gbits sec 3600 Gbytes per tray SAS 2 600G15K 600 Gbyte 3 5 15K RPM SAS 2 drives 6 Gbits sec 7200 Gbytes per tray Array Expansion Module Support The Sun Storage 2530 M2 and 2540 M2 arrays can be expanded by adding Sun Storage 2501 M2 array expansion trays To add capacity to an array refer to the following Service Advisor procedures m Adding Expansion Trays m Upgrade Firmware Caution To add trays with existing stored data contact My Oracle Support for assistance to avoid data loss TABLE2 IOM Code for Sun Storage 2501 M2 Expansion Tray Supported Expansion Array Controller Firmware Tray IOM Code Sun Storage 6180 07 80 51 10 2501 M2 0361 Sun Storage 2500 M2 Arrays Hardware Release Notes 5 Data Host Requirements m Multipathing Software on page 6 m Supported Host Bus Adaptors HBAs on page 8 m Supported FC and Multilayer Switches on page 12 Multipathing Software TABLE
32. s mesures de secours de sauvegarde de redondance et autres mesures n cessaires son utilisation dans des conditions optimales de s curit Oracle Corporation et ses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre des marques appartenant d autres propri taires qu Oracle AMD Opteron lelogo AMD etlelogo AMD Opteron sont des marques ou des marques e d Advanced Micro Devices Intel et Intel Xeon sont des marques ou des marques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc UNIX est une marque d pos e conc d e sous licence par X Open Company Ltd Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers En aucun cas Oracle Corporation et ses affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des contenus produits ou services tiers ou leur ut
33. tached behind the controllers Use the latest version of Sun Storage Common Array Manager to manage the arrays See About the Management Software on page 3 for more information About the Management Software Oracle s Sun Storage Common Array Manager CAM software is a key component for the initial configuration and operation of Sun Storage 2500 M2 Arrays hardware It is installed on a management host cabled to the array via out of band Ethernet Note In band management is also supported To download CAM follow the procedure in the section Downloading Patches and Updates on page 3 Then review the latest Sun Storage Common Array Manager Quick Start Guide and Sun Storage Common Array Manager Installation and Setup Guide to begin installation CAM documentation can be found here http www oracle com technetwork documentation disk device 194280 html Downloading Patches and Updates To download patches and updates from My Oracle Support including the CAM management software follow this procedure 1 Sign in to My Oracle Support https support oracle com 2 At the top of the page click the Patches amp Updates tab 3 Search for software and patches in one of two ways m If you have a patch number Sun Storage 2500 M2 Arrays Hardware Release Notes 3 a Under the Patch Search section click the Search tab b In the Patch Name or Number field enter the patch number For example 10272123 or 1414
34. ultipathing os Software Minimum Version Host Type Setting Notes SLES 11 1 DMMP IM gt See Device Mapper Multipath DMMP for the Linux Operating System on page 13 Windows 2003 SP2 R2 MPIO 01 03 0302 0504 Windows 2003 Non clustered Non clustered Windows 2003 2008 MPIO 01 03 0302 0504 Windows Server You must use MPIO for MSCS Cluster 2003 Clustered 7 10 and above Windows 2008 R2 SP1 MPIO 01 03 0302 0504 Windows Server 64 bit only 2003 Although the minimum is stated Oracle recommends the latest update be installed TABLE4 Supported SAS Multipathing Software Multipathing os Software Minimum Version Host Type Setting Notes Solaris 10 MPxIO Update 9 Solaris with Multipathing software MPxIO included in Solaris OS 10 Oracle Linux 5 5 RDAC 09 03 0C02 0453 Linux RHEL 5 5 RDAC 09 03 0C02 0453 Linux Windows 2008 MPIO 01 03 0302 0504 Windows clustered Windows 2008 R2 Windows non clustered Windows 2003 SP2 MPIO 01 03 0302 0504 Windows clustered Windows non clustered Sun Storage 2500 M2 Arrays Hardware Release Notes 7 Supported Host Bus Adaptors HBAs HBAs must be ordered separately from Oracle or its respective manufacturers To obtain the latest HBA firmware a For Fibre Channel HBAs download firmware from My Oracle Support using keyword HBA For download instructions see Downloading Patches and Updates on page 3 a For SAS HBAs go to http www 1si com su
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi taxe de séjour Monitor - American Diagnostic Corporation ESPECIFICACIÓN DE PRODUCTO VEGEfast Diet Fresa VSP 112U User Manual Méthodologie CIM Radio Vague 2012-2 Owner`s Manual CableWholesale IDC-10/DB9 Chevrolet Opala / Caravan 1969 a 1980 modelo 70 Tracheostoma Housings — 37587-01F Copyright © All rights reserved.