Home
Sun StorageTek 5800 System Release Notes
Contents
1. Entering the commands hwstat hwstat v and sysstat v shows the disk status as disabled and not as initializing while the disk is being enabled This is confusing and can lead to a duplicate enable operation being performed Timeout for Invalid Schema File Bug 6411146 If you attempt to commit an invalid schema xm1 file with the mdconfig c command the CLI becomes non operational and eventually times out Sun StorageTek 5800 System Release Notes 5 MisleadingIndicator of Utilization Relative to Total Space Bug 6421305 Note the following with the df command m df reports raw storage utilization You can use df effectively to view raw storage statistics for each disk in the cluster Therefore used is not equivalent to the total number of Object bytes stored in the system For example it includes space consumed by data parity Object headers and footers query indexes and so on m df statistics are refreshed every three minutes Storage utilization statistics reflected by df are refreshed every three minutes a 15 of storage capacity is reserved for recovery When using df to view storage utilization be aware that the system reserves 15 of raw storage This space is available so data recovery can be completed should a node or disk fail on a full cluster Misleading Data Integrity Verified Message Bug 6421293 If you power up the system access the CLI and then enter sysstat a Data Integrity Verified indication appears
2. 11 Service Contact Information 11 3 iv Sun StorageTek 5800 System Release Notes May 2006 Sun StorageTek 5800 System Release Notes This document contains important information about the Sun StorageTek 5800 system that was not available at the time the product documentation was published Read this document so that you are aware of issues or requirements that can affect the installation and operation of the Sun StorageTek 5800 System m Features in This Release on page 1 a List of Platform APIs on page 2 a Known Issues on page 2 m Release Documentation on page 11 m Service Contact Information on page 11 Features in This Release The Sun StorageTek 5800 system is an online storage appliance featuring a fully integrated hardware and software architecture in which the disk based storage nodes are arranged in a symmetric cluster The clustered and redundant design provides high availability good performance and exceptional data integrity The Sun StorageTek 5800 system provides the following features m Storage control data and metadata path operations distributed across the cluster to provide reliability and performance scaling m Total symmetry in both hardware and software No single point of failure with non disruptive serviceability that includes fail in place components for deferred maintenance m Optional storage of metadata associated with all data for easy reference and parallel
3. Configuration Bug 6405506 If you configure an SMTP server and a port in the CLI using the netcfg command the switch will not recognize the port you configured Sun StorageTek 5800 System Release Notes May 2006 Executing Configuration Changes with Reboot Bug 6406170 When you make a configuration change certain properties require a reboot to take effect Once the change is entered however you can no longer determine the current value since the netcfg command shows the new pending value instead You also cannot tell that the displayed value is a pending value and that a reboot is still required No CLI Error Message When System is Non Operational Bug 6241900 If you log in to the system enter the CLI help command and then enter additional commands such as version and sysstat an immediate exit from the login session results No error message is displayed Adding the v Option to Certain Commands Bug 6403938 Should you inadvertently add the v or verbose option to certain CLI commands such as hwcfg where its use is not supported the following error appears unknown error Can t find resource for bundle java util PropertyResourceBundle key common version name NullPointerException in Alert Code Bug 6408010 Should you use the wipe command a NullPointerException appears on the console The operation will continue despite the appearance of this error Inaccurate Disk Status Message Bug 6409249
4. search capability against an in memory metadata index Automated integrity and placement algorithms that eliminate redundant array of inexpensive disks RAID configuration and volume management Fully integrated load and capacity balancing technology A virtual view file system interface for auxiliary archive access using the Web based Distributed Authoring and Versioning WebDAV protocol A Software Developers Kit SDK with Application Programming Interfaces APIs documentation and an emulator List of Platform APIs This section provides an approved platform list for the Sun StorageTek 5800 system Application Programming Interfaces APIs including 2 Java library C library WebDAV Known Issues This section provide information about functional limitations and bugs filed against this version 1 0 product release Note that if a recommended workaround is available for a bug it follows the bug description The section contains the following topics Functional Limitations on page 3 Installation and Initial Configuration Issues on page 3 CLI Issues on page 4 Client API Issues on page 6 General Issues on page 7 Note that if a recommended workaround is available for a bug it follows the bug description Sun StorageTek 5800 System Release Notes May 2006 Functional Limitations The functional limitations of the version 1 0 release are as follows m Scaling to integrated multip
5. At this point however the Data Doctor tool has not completed a lost fragment recovery cycle and is unable to determine whether or not all data fragments are indeed accounted for No Node Identifiers With sysstat verbose Bug 6421314 If you enter the sysstat command and its verbose option the system output that appears does not include node identifiers Updating the Schema During a Load Bug 6427699 If you attempt to update the schema using mdconfig while a system load is occurring the result is that the database becomes suspended in a create schema state Client API Issues This section describes known issues and bugs related to using the client API 6 Sun StorageTek 5800 System Release Notes May 2006 IllegalStateException Error With a QueryPlus Operation Bug 6395771 Harmless errors are printed to stdout during query operations with a select clause For a cluster they are displayed in the log For the emulator these errors are written to the shell where the emulator is launched Data Space Not Reclaimed in Emulator Bug 6403951 The emulator supports the Delete Metadata operation of NameValueObjectArchive delete and hc_delete_ez However the emulator does not remove the underlying data file when the last metadata record is deleted The semantics are correct but the underlying space is not reclaimed Emulator Installation Directory Must Not Contain Space Characters Bug 6407770 If you try to install t
6. Bug 6402543 When moving a rack there is no way to power all the components down since the CLI shutdown command powers down only the nodes Unable to Start or Shut Down the Database Bug 6392770 Starting up or shutting down the cluster without all nodes being online may force the query indexes to be rebuilt Until the rebuilding process is finished query results may be incomplete See the sysstat command for the status of the query engine Inconsistent Date Reporting Bug 6408658 If you attempt to determine when a file or directory was last modified or created be aware that there are inconsistencies in date reporting For example the directory listing get lastmodified might show a significant offset from Coordinated Universal Time UTC while the creationdate is about the same time without the offset These times should be similar or very close Node BIOS Issue Bug 6413587 When the Sun StorageTek 5800 node BIOS is booting up the following two conditions may occur m The BIOS fails to boot successfully and becomes non operational m The BIOS detects a false fan failure on one or more fans and shuts down Workaround Power on the node again through the front panel power switch If this does not fix the problem remove the power cord wait 30 seconds and then connect the power cord once more Sun StorageTek 5800 System Release Notes 9 Switch Failover Does Not Produce Switch Failover Alert Bug 6402478 Despite
7. S amp o SUN microsystems Sun Storage Tek 5800 System Release Notes Sun Microsystems Inc www sun com Part No 819 3813 10 May 2006 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology fiat is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the one may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Sun StorageTek Java AnswerBook2 docs sun com et Solaris are trademarks or register
8. e les droits de propri t intellectuels relatifs la technologie d crite dans ce document En particulier et sans limitation ces droits de propri t intellectuels peuvent inclure un ou plusieurs des brevets am ricains list s sur le site http www sun com patents un ou les plusieurs brevets suppl mentaires ainsi que les demandes de brevet en attente aux les tats Unis et dans d autres pays Ce document et le produit auquel il se rapporte sont prot g s par un copyright et distribu s sous licences celles ci en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y ena Tout logiciel tiers sa technologie relative aux polices de caract res comprise est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit peuvent d river des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Sun StorageTek Java AnswerBook2 docs sun com et Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux tats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sou
9. ed trademarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees viho implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc poss d
10. es VIPs However you cannot change the service node s IP address Thus if you have a conflict with the predefined factory service node IP you will be unable to change it Contact your Sun service representative for assistance Sun StorageTek 5800 System Release Notes 3 4 CLI Issues This section describes known issues and bugs related to using the command line interface CLI ssh Command Error Bug 6247537 After a master failover occurs the following message may appear on the console when you log in to the CLI WARNING REMOTE HOST IDENTIFICATION HAS CHANGED IT IS POSSIBLE THAT SOMEONE IS DOING SOMETHING NASTY Someone could be eavesdropping on you right now man in the middle attack It is also possible that the RSA host key has just been changed This message is innocuous and can be ignored No Warning When hwcfg disable DISK 1XX X Fails Bug 6327227 If disabling a disk fails for example because the disk cannot be unmounted no warning message is displayed Use hwstat v to view the status of the disk Using mdconfig Before the Database Is Ready Bug 6380366 If you access the CLI and type the mdconfig command before the database is ready the following error message is displayed Timed out waiting for the state machine Workaround Ensure that the database is operational by entering sysstat before using the mdconfig command Unrecognized Port
11. he Software Development Kit SDK the emulator configuration script fails if the specified directory name contains spaces Limitations on the Overall Metadata Size of Stored Data Items Bug 6427145 When using the C API the overall metadata size of a stored data item is limited to 76384 bytes The exact maximum size depends on many factors and should not be relied on This limitation does not apply to data stored using the Java API Limitations on Metdata Values Containing Non Printable Characters Bug 6427141 The behavior of metadata values that contain non printable characters is not guaranteed In particular two known limitations are that metadata values cannot contain the null character and that metadata values that contain the lt LF gt character will have the lt LF gt values silently removed in the stored value General Issues This section describes general issues related to the Sun StorageTek 5800 system Cryptic Error Message When Deleting a Deleted Object Bug 6187582 Deleting an object twice produces the following error message Sun StorageTek 5800 System Release Notes 7 8 ERROR failed to retrieve object request failed with status 400 no oa ctx The error message should say ERROR failed to retrieve object request failed with status 400 noSuchObject Supported Metadata Type Bug 6194366 The supported metadata type field double does not work in views in the version 1 0 relea
12. le clusters is not enabled a Disaster protection by way of user level replication is the only native capability m The maximum queryable size for a single metadata attribute is 512 bytes for data stored on a cluster and 256 bytes for data stored in the emulator It is recommended that you adhere to a string size limit of 256 bytes in both the emulator and the cluster m The current behavior of indexable string attributes is as follows The first 512 bytes of the string value 256 bytes when using the emulator are stored in the metadata database and can be queried against a When using RetrieveMetadata the entire data value is retrieved a When using QueryP lus only the queryable portion of the data value is retrieved that is the first 512 or 256 bytes Ina query string literals longer than the maximum queryable size are also silently truncated to the same limit Installation and Initial Configuration Issues This section describes known issues and bugs related to installing and initially configuring the Sun StorageTek 5800 system Server Node Fails to Start Bug 6403228 When you attempt to bring up a server node with missing or faulty disks that server node might fail during the startup procedure Contact Sun Support to schedule replacement of the failed drives Unable to Change Service Node IP Configuration Bug 6405531 You can use netcfg and ifconfig to change the cluster administrative and data virtual IP address
13. s licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux tats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface utilisateur graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox dans la recherche et le era pement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique Sun d tient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox cette licence couvrant galement les licenci s de Sun impl mentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALIT MARCHANDE L APTITUDE UNE UTILISATION PARTICULI RE OU L ABSENCE DE CONTREFA ON LD com Ca Adobe PostScript Contents Sun StorageTek 5800 System Release Notes 1 Features in This Release 1 List of Platform APIs 2 Known Issues 2 Functional Limitations 3 Installation and Initial Configuration Issues CLI Issues 4 Client API Issues 7 General Issues 7 Release Documentation
14. se Lost Client Connection Error Bug 6268321 If the client connection is lost during store and delete operations the following error is displayed INFO request failed with IOException Error in parsing the status line from the response unable to find line starting with HTTP Workaround The store failed because of a network problem Retry the operation Inadvertent Double Storage Bug 6187879 Store operations become suspended and then time out in the client If you then try the operation again you might store the same data twice Workaround Delete the second instance of the stored object Avoid Concurrent Delete Operations Bug 6291970 Known issues arise when you perform concurrent delete operations Workaround Until this issue is resolved perform delete operations from a single client connection at a time Extra Time Needed for Store After Idle Time Bugs 6355668 and 6403926 Initial input output I O operations on an otherwise idle cluster may be slower than usual Sun StorageTek 5800 System Release Notes May 2006 Lack of Detail in Email Alerts Bug 6398940 With the exception of the mail header itself email alerts do not provide cluster specific information to enable you to distinguish between systems Workaround Read the mail headers to determine where the alert originated It will be the Administrative VIP configured for the cluster Shutting Down the Service Node
15. the fact that a proper failover alert was not sent the following alert appears indicating that you should perform a cluster assessment Cluster is booting or master failed over Other than by visually inspecting the cluster there is no way to determine if the switch has failed over Potential Disk Replacement Issues Bug 6422741 If you use a good disk from another node during a disk replacement it causes the node to assume the identity of the previous disk owner Workaround Use only new disks when performing a disk replacement Disk Write Cache Enabled Bug 6424800 With disk write cache enabled there is a very small probability that a complete power outage or three simultaneous catastrophic disk failures can result in data loss for recently stored files Testing of the failure scenarios presented here has not yet resulted in any data loss Rebooting Nodes While Operating on the Secondary Switch Bug 6425530 If your primary switch is not functioning and you are operating on the secondary switch rebooting a node repeatedly fails to bring up the data VIP at start up In addition the system configures some unusual interfaces eventually escalates and then reboots once more Rebooting the entire cluster while running on the secondary switch causes the cluster to become non operational Potential Disk Query Unavailable After Five Disk Failures Bug 6423238 In some instances five disk failures will cause the query engine
16. to become disabled Workaround Reboot the cluster and the query engine will automatically repair itself in approximately 12 hours 10 Sun StorageTek 5800 System Release Notes May 2006 Release Documentation Subject Title Part Number Installation and initial Sun StorageTek 5800 System Getting Started Guide 819 3808 10 configuration instructions System administration Sun StorageTek 5800 System Administration Guide 819 3810 10 information System regulatory and safety Sun StorageTek 5800 System Regulatory and Safety Compliance 819 3809 10 information Manual Note In addition there are two programmer guides available for the Sun StorageTek 5800 System including a Client API Reference part no 819 3811 10 and an SDK Developer s Guide part no 819 5501 10 For copies of these documents contact your local sales or support representative Service Contact Information If you need help installing or using this product go to http www sun com service contacting Sun StorageTek 5800 System Release Notes 11 12 Sun StorageTek 5800 System Release Notes May 2006