Home

Netra X4200 Server Just the Facts

image

Contents

1. commands vastly reducing administrator overhead Easily integratable with enterprise management tools Sun Customer Ready Systems CRS program For factory configured pre racked custom Netra X4200 M2 servers refer to the CRS program website http www sun com crs Simplification and speed of system deployment Product Family Placement This product is a new entry in the Netra 2U product line The Netra X4200 M2 server is Sun s first Netra server to incorporate the Next Generation AMD Opteron all dual core processors The Netra X4200 M2 server is optimized for network workloads and is able to handle compute and floating point intensive applications with large amounts 32 GB of memory It is a complimentary product to the Netra T2000 and is applicable for those customers that have standardized on the X86 architecture and require support for multiple operating systems Feature Comparison of Netra X4200 M2 and Sun Fire X4200 M2 Servers Feature Netra X4200 M2 Server Sun Fire X4200 M2 Server CPUs Next Generation AMD Opteron 2000 Next Generation AMD Opteron 2000 HE Series embedded processors Series processors dual core only dual core only CPU Speed 2214 HE 2 2 GHz 2220 SE 2 8GHz 2218 2 6 GHz 2216 2 4GHz 2210 1 8 GHz Level 2 Cache 1 MB Level 2 cache per core 1 MB Level 2 cache per core CPU Interconnect HyperTransport 4 GB s HyperTransport 4 GB
2. 7 Product Family Placement 2 nette mete aet p T RE E ep Re PR 10 Farget USCS ss ccce pete eR ND ne c ien ipa tpi E e REM e metre t 12 UI LTD ILI P ease 12 14 Market Value Proposition Fe E ERR FRETI cusshe ERROR 14 14 Enabling 10 ro 15 Next Generation AMD Opteron Processor Basics sseessesesesseessseesssrereesresrererrrerertensesrsststrettsreeteseeernsererseesrsset 15 HyperTransport Techinology ee ttt e RR PEE ERR RERO 16 Intel s Front side Bus FSB Architecture AMD Direct Connect Architecture 16 New Next Generation AMD Opteron Processor Enhancements sese 17 AMD PowerNow EM Technology titre rot rr eR ERR CFR RR ETICE 17 Solaris Support for POWeftNOW iiie teer ee HER eR S ER UA pee e are e RE eite dietus 18 AMD VirtualizationTM Technology eese 18 System Architecture 19 OVerVIeW eei iere tg ER RE RERO E EE RED Re ODER ne Rd 19 QV ELVIS Wass S
3. 5 SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 48
4. e T A 46 Materials 48 amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 4 Positioning Figure 1 Netra X4200 M2 server Introduction Deregulation and privatization has created intense competition in the worldwide telecommunications market over the past few years The marketplace continues to evolve as voice and data solutions become more integrated and next generation wireless video and messaging technologies emerge Growing demand for scalable and available services coupled with modern economic realities are re shaping the design of the telecommunications infrastructure Now more than ever availability of key services can dictate success or failure with stringent service level agreements increasingly common At the same time today s challenging economic climate means that successful organizations must consider issues such as total cost of ownership TCO and investment protection to make sure their decisions make long term business sense The Netra X4200 M2 server delivers dramatic performance and flexibility along with space and power efficiency to meet the increasing demands of the network infrastructure The Netra X4200 M2 server is Sun s first Netra server to incorporate the Next Generation Advanced Micro Devices AMD Opteron all dual core processors Next Generation AMD Opteron pro
5. 20 Power Supplies E M 21 Front and Back Panel Features eese 21 CODnectlVILy eei eee e pee D RR Pe debet eret e Er det E bote e Uo estate peat ure 22 Reliability Availability and Serviceability RAS rece eee eee eese eese eee etas ense tne ta setas tne 24 ASNEI2U CT 25 Netra X4200 M2 Server Operating Systems essen 25 Supported Operatng Systems ent tite debe Peto med e e He edente fter ee 25 Firm Ware and Divers sere t ERE ti t e e E ERR REO tei eee et eins 25 Supported I O Cards enr bet e tae a t URS 25 Supported Storage and Associated S nennen nennen 25 Solaris 10 OS The most advanced operating system on the 1 26 Linux Complementing Sun s Solaris OS Strategy sesesssssessessseseeeeeeeeeere nennen eerte rene 27 Windows OS ve is enses bM et pan oie perpe euis ele 28 System Managements L 29 Sun Integrated Lights Out Manager 29 Sun N1 System Manager Management of One to Thousands of Sun Systems esee 29 Watchdog Timer en eee eive tet HEC IRR pb rS ER 30 Mus EC U TDI EE 31 Processor Opt
6. DIMM slots for a total of eight DIMM in a two CPU system There is a 6 4 GB sec access between processor and memory and one 1GHz 16x16 HyperTransport link between the two processors 8 GB sec Bandwidth Through HyperTransport each processor can access the other processor s memory In a system with a single CPU the processor must be placed into the designated processor slotO that connects to the rest of the I O infrastructure this processor only has access to 2 pairs of memory slots or maximum of 16GB using 4GB DIMMs The Netra X4200 M2 server supports 1 GB 2GB and 4 GB registered DDR2 667 memory for a system with up to a total of 32 GB of memory For optimal performance in both servers memory DIMMs need to be installed in pairs so the processor is able to run in 128 bit ECC mode Systems with an odd number of DIMMs are supported but the processor will run in 64 bit ECC mode reducing performance On board management for the Netra X4200 M2 server is provided by a separately powered Service Processor SP based on a Motorola MPC8248 microcontroller that communicates with the two main system processors and the rest of the system Accessible to the end user through a serial port and a dedicated 10 100 Ethernet NIC ILOM provides the administrator with full lights out manageability of the these servers which includes the ability to power cycle setup manage monitor and maintain the system locally or remotely ILOM supports both local and remote ma
7. ECC DDR2 667 memory four 146 GB 2 5 inch 10000 rpm SAS hard disk drives two DC power supplies RoHS 5 compliant Netra X4200 M2 Server 1x AMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 2x 1GB registered ECC DDR2 667 memory one 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two AC power supplies RoHS 5 compliant Netra X4200 M2 Server 2xAMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x2GB registered ECC DDR2 667 memory two 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two AC power supplies RoHS 5 compliant Netra X4200 M2 Server 2xAMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x4GB registered ECC DDR2 667 memory two 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two AC power supplies RoHS 5 compliant Netra X4200 M2 Server 2xAMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x4GB registered ECC DDR2 667 memory four 146 GB 2 5 inch 10000 rpm SAS hard disk drives two AC power supplies RoHS 5 compliant Sy amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 35 Power Cord Kits The Netra X4200 M2 server comes standard with two power supplies A no charge power cord kit option must be ordered for each AC power supply Available power cord kits include X311L AC power cord U S Brazil Asia except China AC power cord RoHS X312L
8. Engineering Task Force that provides authentication and encryption over the Internet Unlike SSL which provides services at layer 4 and secures two applications IPSec works at layer 3 and secures everything in the network Intelligent Platform Management Interface System management architecture for providing an industry standard interface and methodology for system management Also referred to as Ecache or External Cache A memory cache external to the CPU chip The AMD Opteron processor integrates 1 MB of L2 cache per CPU Mean Time Between Failures The average time a component works without failure Simple Network Management Protocol A set of protocols for managing complex networks The first versions of SNMP were developed in the early 80s SNMP works by sending messages called protocol data units PDUs to different parts of a network SNMP compliant devices called agents store data about themselves in Management Information Bases amp Sun microsystems Sun Confidential Internal and Sun Channel Partners Use Only 46 Hot pluggable Hot swappable Carrier grade NEBS Just the Facts August 2007 MIBs and return this data to the SNMP requesters A feature that allows an administrator to add or remove a device such as a disk drive without affecting hardware system integrity A feature that allows an administrator to remove and or replace a device without affecting software integrity This means that wh
9. Keyboard Video Mouse KVM and remote media capability Video redirection Remote power control remote access to BIOS remote FRU status Remote Keyboard Video Mouse KVM and remote media capability Video redirection Remote power control remote access to BIOS remote FRU status Remote Keyboard Video Mouse KVM and remote media capability Video redirection Remote power control remote access to BIOS remote FRU status System management paths A single dedicated management 100BaseT port system serial port and four system Ethernet ports A single dedicated management 100BaseT port system serial port and four system Ethernet ports NEBS Level 3 Certified N A Telco Alarms YES NO Feature Comparison with Other Netra Rack Servers Feature Netra X4200 Netra T2000 Netra 240 Netra 440 CPUs Next Generation 4 6 8 core Up to two 1 5 GHz Up to four 1 6 GHz AMD Opteron 2214 1 0 1 2 GHz UltraSPARC Ii UltraSPARC CPUs HE Series embedded UltraSPARC T1 CPUs CPUs processor dual core only Threads 2 per CPU 32 max 1 per CPU 1 per CPU 4 max 2 max 4 max Max memory 32 GB 32 GB moving to 64GB 16 GB 32 GB Max internal Up to two 146 GB Up to two 146 GB w Up to two 146GB Up to four 146GB 15K disk drives w DVD or four DVD or four 146 GB 15K Ultral60 SCSI Ultra320 SCSI Just the Facts August 2007 amp SUN microsystems Sun Confidential
10. Keyboard Mouse Video Storage KVMS Remote media capability floppy CD etc Full DMTF CLI Browser UI for control of the system through a graphical interface IPMI 2 0 compliant for management and control SNMP v2c for system monitoring Monitor and report system and component status on all FRUs All management which does not require physically touching the system can be performed remotely Easily integrates into customer s existing management environment by supporting industry standards ILOM is a core part of system there is no additional charge for this functionality as with the competition System Manager Optional software provides complete hardware life cycle management for Sun systems from a single central console Available for a no cost download at http www sun com software products system manager in dex xml Functions include Reduces total cost of ownership and increases efficiencies of managing groups of Sun systems supports SPARC and x64 systems Provides fast and easy access to systems for monitoring and maintenance from a single centralized console Enables one to many grouped Just the Facts August 2007 amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only 9 Bare metal discovery firmware updating OS patching OS Provisioning Monitoring Event logging
11. M2 Server W9D N87 24 3G 3 year upgrade to SunSpectrum Gold 24x7 for Netra X4200 M2 Server W9D N87 3G 3 year upgrade to SunSpectrum Gold for Netra X4200 M2 Server W9D N87 3S 3 year upgrade to SunSpectrum Silver for Netra X4200 M2 Server Sun System Service Plans for Windows OS The Sun System Service Plans for Windows OS are designed to be flexible enough to cover most customers requirements for support Highlights Integrated whole system support for Sun s X64 systems running Microsoft Windows All the essentials for one great price Priority service No per incident limits Warranty Upgrade to Sun System Service Plans for Windows OS for Netra X4200 M2 Server The following are part numbers and descriptions for the warranty upgrade to Sun System Service Plans for Windows OS Just the Facts August 2007 W9D N87W 1S Upgrade to 1 year Sun Windows Silver Support for Netra X4200 M2 Server W9D N87W 1G Upgrade to 1 year Sun Windows Gold Support for Netra X4200 M2 Server W9D N87W 1P Upgrade to 1 year Sun Windows Platinum Support for Netra X4200 M2 Server W9D N87W 28 Upgrade to 2 year Sun Windows Silver Support for Netra X4200 M2 Server W9D N87W 2G Upgrade to 2 year Sun Windows Gold Support for Netra X4200 M2 Server W9D N87W 2P Upgrade to 2 year Sun Windows Platinum Support for Netra X4200 M2 Server W9D N87W 3S Upgrade to 3 year Sun Windows Silver Support for Netra X4200 M2 Server W9D N87W 3G Upg
12. PCI X 4 HyperTransport PCIX Building block structure 1 0 Tunnel 1 0 Up to 5 devices supported in chain Device N EIDE Ethernet HyperTransport USB pem m 1 0 Hub LPC IEEE 1394 gt PCI Bus 33MHz 32 bit Figure 3 Sample HyperTransport Technology Interconnect Block New Next Generation AMD Opteron Processor Enhancements The Next Generation AMD Opteron Processor Design for Socket F 1207 formerly known as Rev F is a redesign of the original Dual Core AMD Opteron formerly known as Rev E design and offer the following enhancements New socket design all native dual core processors Consistent processor power requirements Supports lower power DDR2 memory technology Consistent socket design and power requirements planned for Quad Core AMD Opteron processors AMD PowerNow Technology AMD Virtualization support formerly known as Pacifica AMD PowerNow Technology AMD PowerNow 15 a dynamic processor voltage and frequency throttling technology that works in conjunction with a server s BIOs and the operating system to minimize power consumption under less than maximum workloads amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 17 For AMD PowerNow technology to work both the operating system and server BIOS must be qualified to run AMD s PowerNow Please see below for specific produc
13. Use Only 42 More information is available at http www sun com service support sunspectrum SunSpectrum service plan highlights include Integrated whole system support All the essentials for one great price Priority service No per incident limits Includes Solaris Operating System releases and updates Resources for proactive system management A choice of four simple plans Proven return on investment SunSpectrum Service Plans Features Platinum Gold Silver Bronze Service Plan Service Plan Service Plan Service Plan Mission critical Systems Business critical Systems Basic System Support Self Maintenance Support One stop Interoperability Assistance Solaris Releases Online System Admin Resources SunSpectrum eLearning Library Customer sites meeting an annual SunSpectrum contract minimum approximately 160 000 USD Additional Services for can receive additional services including the creation of a personalized support plan periodic Qualifying Sites support reviews patch assessments and educational services For local qualification criteria visit sun com service support localinfo html Availability of specific features coverage hours and response times may vary by location or product Response times are determined by customer defined priority The response times shown are for service requests designated by the customer as Priority 1 To receive the best support Sun recommends that
14. of bare metal Sun Fire X2100 Sun Fire X2100 M2 Sun Fire X2200 M2 X4100 X4200 X4500 X4600 V20z and V40z systems and Sun Blade 8400 Server Modules In addition this software also supports Sun SPARC systems Sun Fire V210 Sun Fire V240 Sun Fire V440 Netra 240 Netra 440 Netra T2000 Netra X4200 M2 Sun Fire T1000 and T2000 systems Key features include Discovery of systems Hardware Monitoring Grouping for one to many commands OS Monitoring Bare Metal OS Provisioning Event Notification System BIOS firmware and OS updates Event Logging Role Based Access Control Lights Out Management Hybrid UI with browser and CLI AS amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 29 ILOM Watchdog Timer ILOM features a watchdog mechanism to detect and respond to system hang should one ever occur The ILOM watchdog is a timer that is continually reset by a user application as long as the operating system and user application are running In the event of a system hang the user application is no longer able to reset the timer The timer will then expire and will perform an action set by the user eliminating the need for operator intervention One of the benefits of the Netra X4200 M2 Watchdog Timer functionality is the end to end coverage from power on reset through BIOS and OS boot to user application execution If enabled in the BIOS setup menus default opera
15. AC power cord Continental Europe RoHS X312E AC power cord China RoHS X386L AC power cord Australia RoHS X312F AC power cord Argentina RoHS X317L AC power cord U K RoHS X314L AC power cord Switzerland RoHS X384L AC power cord Italy RoHS X383L AC power cord Denmark RoHS X312G AC power cord Korea RoHS X332A Taiwan Localized power cord kit RoHS Assemble to Order Configurations ATO Assemble to Order ATO configurations are not available now They will be available in August 2007 The listed configurations and upgrades greatly reduce the need for custom configurations Netra X4200 M2 Server XATO Chassis Options N87 AD Z Netra X4200 M2 Base Chassis Two HDD slots 1 DVD Bay 2 August 2007 DC PSU RoHS 5 compliant N87 AA Z Netra X4200 M2 Base Chassis Two HDD slots 1 DVD bay 2 August 2007 AC PSU RoHS 5 compliant N87 BD Z Netra X4200 M2 Base Chassis Four HDD slots no DVD bay August 2007 2 DC PSU RoHS 5 compliant N87 BA Z Netra X4200 M2 Base Chassis Four HDD slots no DVD bay August 2007 2 AC PSU RoHS 5 compliant AS amp SUN microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 36 Options The following options are supported by the Netra X4200 M2 server Options that include an X in the part number indicate that the part can be ordered as a field installable part or for factory integrati
16. Internal and Sun Channel Partners Use Only Linux Windows Feature Netra X4200 Netra T2000 Netra 240 Netra 440 146 GB w o DVD w o DVD 2 5 SAS 2 5 SAS HDDs HDDs Removable Tray Load DVD RW Tray Load DVD RW Slimline DVD RW Slimline DVD RW media Interfaces Dual USB 2 0 ports Dual USB 1 1 ports 1 x Dual serial Dual Dual serial Four USB 1 x 10MB s Ethernet 10MB s Ethernet one USB 1 x 10MB s One SCSI 1 x 10MB s one serial serial Ethernet one SCSI Ethernet PCI slots Three 133MHZ PCI Three 133MHZ PCI X 3 PCI slots full 6 PCI slots full height X slots full height slots full height 2x full height 1x full length full length 2x full length Ix half length 1x half height 2x half length height One PCI E slot MD2 One PCI E slot MD2 low profile low profile Ethernet Four on board Four on board Gigabit Four on board Two on board Gigabit Gigabit ports ports Gigabit ports ports Form factor 2U 16 7 20 2U 16 7 20 2U 16 7 20 5U 17 32 19 5 Solaris OS Solaris 10 for x86 Beginning with Solaris Solaris 8 9 and 10 Solaris 8 9 and 10 version Red Hat and SuSE 10 6 06 Target Users Target users are found in the following market areas Network equipment providers including wireless and wireline telecommunications infrastructures Service providers deploying data centers POPs or metropolitan area networks Government and military installations Manu
17. Netra X4200 M2 Server Just the Facts SunWIN token 496298 June 2007 Version 1 2 icrosystems Copyrights 2006 Sun Microsystems Inc Rights Reserved Sun Sun Microsystems the Sun logo IPX Customer Ready Systems Netra N1 ONC Solaris Sun Fire Sun StorEdge SunSpectrum and SunVTS are trademarks or registered trademarks of Sun Microsystems Inc in the United States and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the United States and other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc UNIX is a registered trademark in the United States and other countries exclusively licensed through X Open Company Ltd AMD Opteron PowerNow HyperTransport the AMD Arrow Logo the AMD Opteron logo thereof are trademarks or registered trademarks of Advanced Micro Devices amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 2 Table of Contents IU IPI E M H 5 Introduction a eg erre treten eme ea endo i men eee pee eet eie ti ene eee 5 Key Message II N 6 Key Product Features Functions and Benefits eseesssseeeseeeeeeeeeeeeee nennen eene enne
18. RAID 0 Integrated Mirror or IM volumes RAID 1 Power Supplies The Netra X4200 M2 server is equipped with a dual redundant hot swappable power supply system One power supply is sufficient to run a fully populated server however for maximum protection against power supply failures Sun recommends that both power supplies be installed in the system at all times The power supplies are rated at 550 watts each In normal operation the power supplies share the power demands of the system equally between the pair Refer to the Specifications section for more information on power ratings Front and Back Panel Features amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 21 Figure 7 Netra X4200 server rear panel features Connectivity Networking The Netra X4200 M2 server includes four on board auto negotiating Gigabit Ethernet ports These ports are all capable of providing simultaneous full bandwidth operation with no shared bandwidth limitations Each of the four Ethernet RJ45 connectors is associated with two LEDs one to indicate link status the other to indicate network activity In addition a dedicated 10 100BASE T network management port is available on the back panel for a remote management connection to the ILOM Service Processor Sy amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners
19. ST R BSMI MIC UL cUL pending UL DEMKO GS UL S mark CCC ETSI EN 300 019 2 1 2 3 Class 1 2 2 3 3 1E Except 5 C cold start Except condensing humidity Except rain Seismic GR 63 CORE requirements for earthquake zone 4 Just the Facts August 2007 AS amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only 33 Ordering Information Standard Configurations Preconfigured Systems The Netra X4200 M2 server run the Solaris 10 Operating System on x64 as well as standard Linux distributions and Microsoft Windows Server 2003 Enterprise and Standard Editions For a list of supported OS versions please refer to section Netra X4200 M2 Server Operating Systems Support The Netra X4200 2 server can be ordered using the configuration part numbers listed in this section servers ship with one or two dual core Next Generation AMD Operton processor Model 2214 HE embedded class The processor in the Netra X4200 M2 runs at 2 2GHz with a 1 MB L2 cache Two power cords for the AC version specific to the environment or geography must be ordered as a separate line item base configurations include 2 RU packaging Three PCI X slots 3x full height 2xfull length 1xhalf length Up to two AMD Opteron socket F 1207 2214 One Slimline tray loaded DVD drive HE embedded class dual core processors Eight memory slots supporting registered Two USB 2 0 ports and one
20. Use Only 22 USB Ports The Netra X4200 M2 server comes with two USB 2 0 ports The two ports are located on the right side of the rear of the panel Telco Alarm Port A DB15 connector is provide Telco alarm access to the system The telco alarm function and connector pinouts are same as Netra 210 Netra 240 Netra 440 Netra T2000 systems amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 23 Reliability Availability and Serviceability RAS Reliability availability and serviceability RAS are aspects of a system s design that affect its ability to operate continuously and to minimize the time necessary to service the system Reliability refers to a system s ability to operate continuously without failures and to maintain data integrity System availability refers to the ability of a system to recover to an operational state after a failure with minimal impact Serviceability relates to the time it takes to restore a system to service following a system failure Together reliability availability and serviceability features provide for near continuous system operation To deliver high levels of reliability availability and serviceability the Netra X4200 server offers the following features Simplicity of design with the AMD Opteron processors and HyperTransport requires less components and thus provides higher reliability ECC memory with ChipKill supp
21. VGA port HD 15 DDR2 667 MHz ECC DIMMs Two disk drive bays and DVD or Four disk Integrated lights out manager ILOM with drive bays and no DVD dedicated 100BASE T Ethernet port and RJ45 serial port Four 1 Gigabit Ethernet ports One 19 inch 4 post rackmount kit One PCI E slot MD2 low profile Two 550W 1 1 hot swappable DC or AC power supplies S amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 34 Standard Configuration Part Numbers eee rere N87 SFZ22H8GLBD N87 SFZ22H16GLBD N87 SFZ22H16GLDD N87 SFZ12H2GLAA N87 SFZ22H8GLBA N87 SFZ22H16GLBA N87 SFZ22H16GLDA Netra X4200 M2 Server 1x AMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 2x1GB registered ECC DDR2 667 memory one 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two DC power supplies RoHS 5 compliant Netra X4200 M2 Server 2xAMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x2GB registered ECC DDR2 667 memory two 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two DC power supplies RoHS 5 compliant Netra X4200 M2 Server 2xAMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x4GB registered ECC DDR2 667 memory two 146 GB 2 5 inch 10000 rpm SAS hard disk drives DVD drive two DC power supplies RoHS 5 compliant Netra X4200 M2 Server 2x AMD Opteron Model 2214 HE dual core processor 2 2GHz 1MB 4x4GB registered
22. able to support legacy telco PCI cards that are still full height and full length The provided slots are both 133MHz 64bit wide 3 3V providing the highest speed available for the older cards that are available in PCI X configurations amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 20 Internal Hard Disk I O Subsystem The Netra X4200 M2 server supports up to four hard disk drives controlled by an LSI SAS1064 controller providing four ports of SAS connectivity to disk drives at bandwidths of 3Gb sec full duplex for each disk Disks are NEBS Certified 146 GB 10000 rpm SAS disks 2 5 inch small form factor server grade and are certified for 24x7 operation Due to the small physical size of these drives and the high spindle speeds access times to disk are extremely good AII disks are hot pluggable A benefit of using small disks is that they allow designers to maximize the air intake area at the front of the server to improve airflow further increasing environmental margins and server reliability Hardware RAID striping and mirroring is supported on the Netra X4200 M2 server RAID technology allows for the construction of a logical volume made up of several physical disks to provide data redundancy increased performance or both The Netra X4200 M2 server onboard disk controller supports the following RAID configurations Integrated Stripe or IS volumes
23. ardizing on a x64 platform infrastructure for mixed workloads including single thread multi thread and FP applications In addition the Netra X4200 M2 server is applicable for customers requiring application flexibility and protection of asset investments delivered through full Solaris binary compatibility with support of Linux or Windows based applications The Netra X4200 M2 server reaffirms Sun s commitment to customers who invested in the Netra product line by offering a product that delivers enhanced performance throughput consistent form fit and function Ruggedized packaging and NEBS level 3 certification provides a high level of system reliability which helps ensure that the Netra X4200 M2 server continues to operate under extreme environmental conditions Availability The Netra X4200 M2 server PTO standard configurations have reached general availability Customer specific ATO configurations will lag the RR of PTO standard configurations by at least three months to help provide a smoother production ramp of Customer specific ATO configurations will lag their RR by at least one month amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 14 Enabling Technology Next Generation AMD Opteron Processor Basics The Next Generation AMD Opteron processor leverages the same proven Direct Connect Architecture and CMP Chip level Multi Processing design fea
24. ber Applying the allowance code will calculate the trade in allowance percentage off of the list price of the new Netra X4200 M2 server This trade in allowance is used in addition to the customers VEU discount For a complete list of eligible trade in products you can go to http ibb eng The customer must order an RMA kit with each upgrade and the customer will be required to trade in their old servers within ninety days of shipment of the new server The allowance codes are not applicable to products in CAT D amp Sun Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 41 microsystems Service and Support Warranty The Netra X4200 M2 server features a 1 year warranty Duration 1 year Next Business Day HW coverage hours Business hours HW response times Next business day Delivery Method Parts Exchange or On site HW phone coverage Business hours HW phone response time 8 hours Sun Service Plans Sun Global Customer Services offers a full range of services to assist customers who deploy the Netra X4200 M2 servers Whether it is architecture services implementation services or services to help customers manage the servers once released to production Sun has the right services during every phase of the project s life cycle Sun provides a service plan to meet every customers needs the SunSpectrum Service Plan for full system support ranging from basic to mission crit
25. cessors now support DDR2 memory and come with hardware assisted AMD Virtualization In addition the Next Generation AMD Opteron processors offer a seamless upgrade path to Quad Core AMD Opteron processors with the same consistent socket design The Netra X4200 M2 carrier grade server offers flexibility and choice in a rack optimized less than 20 inch deep 2RU enclosure It runs both 32 bit and 64 bit applications on multiple operating systems and offers the choice of four internal hard drives maximizing storage capacity in a 2RU form factor The Netra X4200 M2 server also integrates four Gigabit Ethernet ports to provide connectivity for high speed high bandwidth networking System uptime is enhanced by redundant hot swappable AC DC power supplies and hot pluggable hard disk drives Additionally the Netra X4200 M2 server comes with Integrated Lights Out Management ILOM enabling simple remote monitoring and management from anywhere on the network providing the kind of reliability and serviceability features that global telecommunication companies demand As with other Netra servers the Netra X4200 M2 is a ruggedized NEBS Level 3 certified and ETSI compliant server making it ideal for the most demanding applications in the toughest environments In addition to supporting the Solaris Operating System the Netra X4200 server also provides support for Linux and Windows operating systems offering customers unmatched agility efficiency and i
26. customers install Sun Net Connect software on SPARC based systems This software creates a secure customer controlled link to the Sun Solution Center which helps enable expedited Solaris OS troubleshooting remote diagnostics and a number of customer enabled alerting and reporting functions Based on Total Economic Impact Study by Forrester Research This study is available at sun com service support sunspectrum amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 43 Warranty Upgrade to SunSpectrum Service The following table includes the part numbers and descriptions for the warranty upgrades to SunSpectrum programs for the Netra X4200 M2 servers W9D N87 1P 1 year upgrade to SunSpectrum Platinum program for Netra X4200 M2 Server W9D N87 24 1G 1 year upgrade to SunSpectrum Gold program 24x7 for Netra X4200 M2 Server W9D N87 1G 1 year upgrade to SunSpectrum Gold for Netra X4200 M2 Server W9D N87 1S 1 year upgrade to SunSpectrum Silver program for Netra X4200 M2 Server W9D N87 2P 2 year upgrade to SunSpectrum Platinum for Netra X4200 M2 Server W9D N87 24 2G 2 year upgrade to SunSpectrum Gold 24x7 for Netra X4200 M2 Server W9D N87 2G 2 year upgrade to SunSpectrum Gold for Netra X4200 M2 Server W9D N87 2S 2 year upgrade to SunSpectrum Silver for Netra X4200 M2 Server W9D N87 3P 3 year upgrade to SunSpectrum Platinum for Netra X4200
27. developed by IBM for situations that demand high availability It allows a system usually CPU or motherboard to detect problems with the computer s memory and selectively disable the problematic DIMMS Error Correcting Code type of memory that corrects errors on the fly Peripheral Component Interconnect Express Formerly known as third generation I O this implementation of the PCI computer bus that uses existing PCI programming concepts and communication standards but bases it on a much faster serial communications system Peripheral Component Interconnect Extended A computer bus technology that increases the speed that data can move within a computer from 66 MHz to 133 MHz Serial Attached SCSI The successor to the original SCSI technology with the ability to address up to 16 256 devices per port It also has a more reliable point to point serial connection at speeds of up to 3 Gbps The most widely used LAN access method defined by the IEEE 802 3 standard uses standard RJ 45 connectors and telephone wire 100Base T is also referred to as Fast Ethernet And 1000Base T is also referred to as Gigabit Ethernet Internet Key Exchange A method for establishing a security association that authenticates users negotiates the encryption method and exchanges the secret key IKE is used in the IPSec protocol Input output Transferring data between the CPU and any peripherals IP Security A security protocol from the IETF Internet
28. dicates the residue group a way of grouping system in the Sun installed base The letters A through X are reserved for Sun systems The letter Z is used for competitive systems N87 Identifies the product family that the customer is purchasing P2 if there is a promotion Promotion code used for tracking corporate sponsored and other types of promotions amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 40 How to Determine the Right Allowance Code Scenario My customer has a Netra 1120 server and would like to upgrade to a Netra X4200 M2 server What allowance part number should I select 1 From left hand column select the platform the customer has 2 The correct allowance part number appears in the right column The correct number for the Sun Fire 280R server is ALW 10 S L N87 This part number is applied to the list price of the standard marketing part number In this case it is a 10 allowance for the old Sun Fire 280R server Entry Level Server Upgrade and Allowance Matrix Sun Fire V100 V120 Netra 120 ALW 05 S L N87 Sun Enterprise 250 220R Netra 1120 1125 Sun Fire V210 V240 V250 ALW 10 S L N87 Sun Enterprise 450 420R 280R V440 XX00 3 to 5 year old competitive systems ALW 05 S Z1 N87 Less than 3 year old non Sun systems ALW 10 S Z2 N87 Upgrade Ordering Notes The ALW code is applied the the system part num
29. el 3 certification Enables continuous operation in earthquake Zone 4 environments complies with regulatory regulations for deployment in central office environments Maximizes availability and decreases downtime due to environmental conditions Ruggedized enclosure Provides the highest levels of protection from temperature fluctuations humidity vibration pollutants or other air contaminants such as dust resist retard fire or other electrical hazards Increases reliability and availability Minimizes downtime due to enviromental conditions 19 inch 4 post rackmount kit and flip down bezel are standard with every system Other rackmount kits available 19 inch 2 post 23 inch 2 post 600mmx600mm and 19 inch 4 post slide rail Provides ease of serviceability and ability to rack system in a variety of industry racks Reduces service time and gives customers the flexibility to rack mount the Netra X4200 in a variety of different industry racks Dry Contact Alarms Four programmable alarms are available in the Netra X4200 M2 server these include Critical Major Minor and User Critical Major and Minor alarms are to be used to denote corresponding system states while User alarm is user definable Enables Telco operators to use a relay to signal fault conditions to a rack or control room panel as well as an alarm monitoring system Redundant AC DC power supplies with separate ru
30. ersion Just the Facts August 2007 AS amp Sun microsystems Sun Confidential Internal and Sun Channel Partners Use Only 37 X4353A Z PCI E Cards Networking Interfaces X 7280A 2 X4447A Z X4446A Z PCI E Cards Security X6000A X6099A Air Filter 10 pack for 4 HDD version Dual port GigE UTP low profile RoHS 6 Quad GbE X8 Quad GbE X4 Crypto Accelerator 6000 SSL IPSec RoHS 6 Sun Crypto Accelerator 6000 Software CD to enable IPsec support Requires a shielded cable to pass ESD discharge requirements at SKV Estimated NEBS complete end August 2007 Estimated NEBS complete end August 2007 PCI X Cards Storage Interfaces SG X PCI2FC QF4 SG X PCI2FC QF2 Z SG X PCI2SCSILM320 Z Dual port 4Gb FC includes standard and low profile brackets RoHS 6 Dual port 2Gb FC RoHS 6 Dual port Ultra320 SCSI includes standard and low profile brackets RoHS 6 SG X PCI2FC EM4 Z Dual port 4Gb FC Estimated NEBS complete end August 2007 PCI E Cards Storage Interfaces PCI PCI X Cards Networking X 4445A Quad GigE RoHS 6 X 4151A 2 GigaSwift Ethernet MMF Adapter RoHS 6 X 7285A Dual port GigE UTP RoHS 6 Please note that the above mentioned X Option PCI cards have been NEBS tested As more cards undergo NEBS testing they will be added to the list General Configuration Notes 1 Single processor systems can be expa
31. facturing Utilities Target Applications The Netra X4200 M2 delivers extreme performance and flexibility with optimum power and space efficiency for the below targeted applications Media Gateway Controller Operations and maintenance for telecommunications network Signaling Gateway ntelligent Network MMS Multimedia Messaging Services 5MS Short Messaging Services Unified Messaging Application Server Web Server Content Caching Network Proxy Home Virtual location registries HLR VLR Just the Facts August 2007 p microsystems Sun Sun Confidential Internal and Sun Channel Partners Use Only 12 Base Station Controller BSC Content Distribution Networks DNS Services Firewall VPN IPSEC P Traffic management e Security Streaming Media Defense Military Intelligence applications include shipboard command and control mobile weapons control and remote intelligence access servers Embedded OEM applications such as industrial process control semiconductor test equipment and network imaging systems amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 13 Selling Highlights Market Value Proposition The Netra X4200 M2 server delivers dramatic performance and flexibility along with space and power efficiency to meet the increasing demands of the network infrastructure It is ideal for customers stand
32. gned with features that include front and back system LEDs front accessible hot swappable drives socketed system configuration chip and modular field replacement units FR Administration and recovery for the Netra X4200 is provided though the Integrated Lights Out Management ILOM The ILOM provides remote monitoring and diagnosis of the system and allows full remote KVMS functionality with video and media redirection In addition the optional Sun N1 System Manager software centralizes lifecycle management discovery configuration provisioning and monitoring of groups of systems DURABILITY Ruggedized e Ruggedized packaging provides a high level of system reliability which helps ensure that the Netra X4200 M2 servers continue to operate under the extremes of environmental conditions COMPATABILITY Investment Protection Customers can standardize on one hardware platform for all major operating systems in their network In addition the Netra X42000 M2 supports full height and full length PCI X cards allowing the use of legacy telecommunication cards Continuity amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 6 e Netra based servers are used around the globe in a variety of locations including telecommunications central offices and wireless base stations Internet data centers metropolitan area networks POPs and enterprise service provider inf
33. ical service levels and the Sun Software Service Plan SunSpectrum Service Plans Get integrated hardware and software support Sun Software Service Plans For fundamental software services such as technical phone or web based support and software maintenance updates and upgrades Sun offers two levels of service for production system software Why the Warranty Isn t Enough While computer system warranties provide business customers with some assurance of product quality they do not provide many essential system services or operating system support In addition warranties provide default repair times and coverage hours which may not suit customer needs It s just that a warranty and a Service Plan are two very different things with two very different objectives Break fix is no way to live make sure your customers have service plan coverage on all their active Sun systems For more information go to http www sun com comparewarranty SunSpectrum Service Plans SunSpectrum service plans provide integrated hardware and Solaris Operating System support for Sun systems as well as comprehensive storage system support For each Sun system customers can choose the service plan that best fits their needs Customers benefit from lower SunSpectrum Instant Upgrade SIU pricing when purchasing support at time of system sale amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners
34. ile the system does not need to be rebooted the new component is not automatically recognized by the system Ruggedized rack mountable systems with features including remote alarm capabilities front back cooling front accessibility of media rear cabling and rugged NEBS compliant packaging Network Equipment Building Standard A stringent standard for durability grounding cables and hardware interfaces specified by Telcordia Technologies formerly Bellcore for equipment used in Telco central offices amp Sun microsystems Sun Confidential Internal and Sun Channel Partners Use Only 47 Materials Abstract materials will be available on SunWIN except where noted otherwise Product Literature Netra X4200 M2 Server Just the Reference Guide this Training SunWIN 496298 Facts document Sales Tool Reseller Web Netra X4200 M2 Server Data Sheet Data Sheet Sales Tool SunWIN 496303 Reseller Web Netra X4200 M2 Server Customer Customer Presentation Sales Tool SunWIN 496307 Presentation Netra X4200 M2 Server Technical Technical Presentation Training SunWIN 496309 Presentation Sales Tool Beating IBM with the Netra X4200 Competitive Beatsheet Sales Tool SunWIN 496316 M2 Server White Papers Netra X4200 M2 Server Architecture White Paper Sales Tool SunWIN 496314 External Web Sites General information on the Netra http sun com netra x4200 X4200 Server S
35. ions ie tiet Becta Gnd Orem et e e e E RD AER ets 31 M in ep 31 Standard Integrated Interfaces octets p tr EORR pe HERE 31 Nnvrul N 31 Environment Specifications i ire sec Sock RUE LEE E Rr bee 32 Power Source Requirements ene depot ee Perrier ee iere tec eie Deed cetur erp 32 Acoustic Noise Emissions iore ep e PR eb e PE Ere EE RE ed eR ipee eben 33 Agency Compliance Specification Sss nn pease ed ng ete teer ie dee ene e deans ee iis 33 Ordering FCD SUICIDE 34 AS amp SUN microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 3 Netra X4200 M2 Server XATO Chassis nennen nennen nennen nennen tenete teret 36 QUI M E EE O 37 Bae E PE T EEEE T EER E 40 Upsrade Paths E E E ERO E EE E EEA 40 Sun Upgrade Allowance Program Sun nne nennen trennen etre eene entente tenete 40 Allowance Code Numbering Scheme oie ce eedem pie rr a p Ebr PERO 40 Upsrade Ordeting Notes ice irte ro D peg te pe dace aid 4l NIIU de H sses 42 LEE 42 SUM eryice Plans sete nn ERE NER pe ee RO echtes 42
36. ive server alternatives Choice and Platform Neutrality right tool for the right job Customers can choose the OS platform to best meet their server to desktop computing needs With the Sun Java Enterprise System for Linux customers can standardize on a set of Java technology based network services across their heterogeneous infrastructure of volume x86 systems based on the Solaris OS or standard Linux to large SMP systems from Sun on x64 or SPARC processor based systems A growing line of Sun and third party Intel Xeon and AMD Opteron processor based servers allows Linux customers to scale to 64 bit computing Systems Approach Simplified Operations One Stop Linux Support AS amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 27 Sun brings a complete systems approach to Linux a value added web services stack for the entire system hardware OS tools and applications backed by Sun s global support infrastructure Delivering Linux from leading vendors Red Hat and SUSE Linux with front line support and training worldwide from Sun on x64 Xeon and Opteron processors hardware platforms from Sun and third parties Selling the simplest and most comprehensive middleware amp web services offering with Sun Java Enterprise System Optimized Java Technology Java Everywhere Broaden the reach of Java technology investments Sun is focused on ma
37. length 1x half length One Internal x8 PCI Express MD2 low profile slot Alarms Four fail safe dry contact alarms critical major minor and user DB 15 Mass Storage and Media Hot swappable 2 5 SAS Internal Up to two 146GB HDDs w DVD Up to four 146GB HDDs w o DVD two disk different chassis Internal DVD One Slimeline DVD RW External disk Leveraged from the Sun Fire X4200 M2 See http www sun com servers entry x4200 storage jsp Software Operating environment Solaris 10 Operating System on x64 64 bit Red Hat Enterprise Linux available May 2007 SUSE Linux available May 2007 Windows Server 2003 available May 2007 Sun Java Enterprise System 4 Solaris 10 on X64 Operating System Standard Linux distributions Languages C C FORTRAN Java programming language all other standard Sun AS amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 31 supported languages Networking Software Management ONC ONC TM NFS TM WebNFS TM TCP IP SunLink OSI MHS IPX SPX SMB technologies and XML CLI in band and out of band IPMI 2 0 in band and out of band SNMP out of band only Physical Specifications 19 inches to the connector plane Description US International Height 3 5 inches 2 RU 89 mm Width 17 4 inches including bezel 442 mm including bezel 16 7 i
38. ls using the out of band management Ethernet or using in band communication through the server s operating system With out of band management the system administrator can remotely control power of the system monitor system FRU status and load system firmware With in band management the system administrator can monitor system status and control system power down The Service Processor SP provides the following functions Capability to remotely manage the server through remote keyboard video mouse and storage redirection Extensive control and reporting over environmentals power hardware and BIOS OS features Remote flash upgrades of system BIOS and service processor software Remote diagnosis of failed components allows for rapid correction User configurable serial console accessible via a physical port or re directed through the management network Sun N1 System Manager Management of One to Thousands of Sun Systems Optional Sun 1 System Manager N1 SM software can provide comprehensive infrastructure life cycle management for Sun systems delivering an efficient way to manage multiple systems across the datacenter while simplifying management tasks reducing repetition and lowering the Total Cost of Ownership of Sun x64 systems N1 SM is provided with a no cost license and is available for download from http www sun com software products system manager index xml This software enables rapid discovery and provisioning of groups
39. ly 15 HyperTransport Technology The Next Generation AMD Opteron processor continues to use HyperTransport Technology links to provide a scalable bandwidth interconnect among processors I O subsystems and other chip sets HyperTransport Technology Helps increase overall system performance by removing I O bottlenecks typically found in Front Side Bus FSB architectures and efficiently integrating with legacy buses increasing bandwidth and speed and reducing latency of processors Provides up to 8 GB sec bandwidth per link at 16x16 bits 1 GHz operation providing sufficient bandwidth for supporting new interconnects such as PCI Express AMDA AMD AMDA AMD p 8 GB S p p n Opteron Opteron Memory Hub Controller Hub Intel s Front side Bus FSB Architecture AMD Direct Connect Architecture Figure 2 Intel versus AMD processor Architecture Intel s Front Side Bus FSB architecture requires a separate memory controller I O bottlenecks and reduced efficiencies are seen as data from CPU to CPU CPU to I O and CPU to memory all funnel through a central Front Side Bus AS Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 16 Device 0 AMD Opteron DDR Memory HyperTransport 1 0 links Processor Up to 8 0 GB sec total bandwidth bi directional at 16x 16 bits 1 GHz operation Device 1 Extensive data protection management Integrated power management
40. n on one power supply the A fully configured system can Increase availability and helps ensure uptime of critical power cords second power supply is for applications redundancy and load sharing S 5 UN microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 8 Four onboard 10 100 1000 Mbps Ethernet ports Exceptional I O performance and increased network reliability by providing redundancy ncreases network efficiency flexibility and availability Four PCI slots three 133 MHZ PCI X full height 2x full length 1x half height one x8 PCI E MD2 low profile For external connections to additional storage etc Full height PCI X slots provide support for legacy telecommunication cards Optional DVD RW Ability to read and write to a removable media access device Enables customers to store data on a removable media access device without external storage or hard drive requirements Support for Solaris 10 OS on x64 Red Hat and SuSE Linux Windows Server 2003 Run applications on industry standard platform running OS of choice Maximize application performance with best OS Ease transition to 64 bit computing Maximize IT investment by standardizing hardware to reduce required training and spares e Lights out Remote Management Sun Integrated Lights Out Manager ILOM Remote management with full
41. nagement including remote KVM and media connectivity ILOM also provides industry standard GUI and CLI interfaces IPMI 2 0 and SNMP V1 v2c V3 support also enable fast integration into a customers existing monitoring schema Refer to the Netra X4200 M2 server block diagram for more details Expansion Slots The Netra X4200 M2 server is well equipped with both legacy PCI X slots and the more current PCI E high speed slot PCI Express Slots PCI Express PCI E is a high speed point to point dual simplex chip interconnect It is designed as the next generation system bus interconnect replacing the aging PCI bus PCI E operates at 2 5GHz and supports lane widths of x1 x4 and x8 in the Netra X4200 M2 server One x8 PCI E slot is provided The slot can also accommodate x1 or x4 cards Most cards including InfiniBand cards currently do not require more than a x4 slot for full bandwidth operation Graphics cards are the only currently available device that can come close to requiring the full x16 operation that PCI E can offer These larger slots are usually provided specifically for graphics cards in high end 3D visualization oriented workstations PCI X Slots Three PCI X slots are provided on the Netra X4200 M2 server to allow customers who need older PCI or PCI X I O cards to continue using the older generation of cards The PCI X slots are all full height and two are full length while one is half length They were designed to be
42. nches no including bezel 424 mm not including bezel Depth 20 inches max depth 508 mm max depth 483mm to connector plane rack mounts Weight approximate without PCI cards or 35165 2 disk version 37 2165 4 disk version 16 kgs 2 disk version 17 kgs 4 disk version Environment Specifications These are the environmental specifications for the Netra X4200 server Specification Operating Non Operating Temperature 5 C to 40 C 41 F to 104 F 40 C to 70 C 40 F to 158 F Short Term 5 C to 55 C 23 F to 131 F Relative Humidity 5 to 85 relative humidity noncondensing Up to 93 relative humidity Short term 5 to 90 relative humidity noncondensing 38 C 100 4 F max noncondensing but not to exceed 0 024 kg wet bulb water kg dry air 0 053 Ibs water 2 205 Ib dry air Altitude Up to 3000 meters 9 850 feet 40 C Up to 12 000 meters 40 000 feet Power Source Requirements The Netra X4200 M2 server has two autoranging AC or DC power supplies To ensure redundant operation of the power supplies the two power inputs should be connected to separate power sources These are the electrical limits and ranges for the Netra X4200 M2 server utilizing 550W power supplies Description AC Specification DC Specification Operating input voltage range 100 to 240 VAC 50 to 60 Hz 48VDC or 60VDC nominal 40VDC to 75VDC range Maximum operating input cu
43. ncy of switching between hypervisor and guest OS s through tagged TLB memory architecture amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 18 System Architecture Overview eccoor 10 7 GB sec SDRAM i BH EN sioe GPE HT ge Dem 2 Rear E an Nvidia G Ren GB SE ac RJ45 GB MS x Ethemet ee kkhk RJ45 Ethernet Connector 1 Motorola MPC8248 PCI X 3 64 133 MHz PCI X 1 64 133 MHz PCLX 2 64 133 MHz PCIE 8 Connector Figure 4 Netra X4200 M2 server block diagram The Netra X4200 M2 server comes with the following major components The Next Generation AMD Opteron 2214 HE embedded class processors Up to 32 GB of DDR2 SDRAM memory in 8 available memory slots Four on board Gigabit Ethernet ports Three PCI X full height 2x full length and 1x half length slots and one PCI Express MD2 low profile slot Up to two SAS disk drives with a tray load DVD or four SAS disk drives with no DVD amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 19 Overview The Netra X4200 M2 server features two CPU sockets that support Next Generation AMD Opteron model 2214 HE L1 socket embedded class processors The server is supported with one or two processors and each processor controls 2 pairs of
44. nded to include source code compatibility as well Linux Compatibility With unwavering support for interoperability and open standards and a commitment to delivering customer choice Sun has made Linux interoperability a high priority Six Key Linux Libraries included in Solaris OS are Glib Gtk JPEG PNG TIFF and XML2 Hundreds of Linux applications and libraries are provided with the Solaris OS including the GNOME desktop Linux Compatibility Assurance Toolkit LinCat helps to simplify the process of porting Linux applications to run natively on the Solaris OS Pricing Support Solaris 10 OS is free to end users upon registration and is available via free download Media kits are available for purchase Support is available at an additional charge Linux Complementing Sun s Solaris OS Strategy Key Messaging Sun the 1 systems provider brings a Comprehensive Systems Approach to Linux providing customers with a full Linux solution of hardware OS choice with Sun s value added Sun Java TM Enterprise System Sun Java Desktop System tools and services Sun enhances standard Linux distributions with an integrated systems offering that includes fully supported OS x64 rack mount servers and the Sun Java Enterprise System that simplifies platform support for customers and partners Sun brings added value to the system offering with faster low cost hardware which is the primary concern for most Linux customers seeking cost sensit
45. nded with a second CPU of the identical model speed only e g AMD Opteron 1x2214 HE embedded class processor based system can only use another AMD Opteron 2214 HE Just the Facts August 2007 AS amp Sun microsystems Sun Confidential Internal and Sun Channel Partners Use Only 38 embedded class processor Single processor system can also be expanded with one additional hard disk drive to a max of two drives The entry level single CPU standard configuration has only 2 memory slots that are usable the other 4 memory slots only work if a second CPU is installed This can be done by purchasing the optional second CPU option Memory must be installed in pairs Pairs of different densities may be mixed e g 2X1GB and 2x2GB on CPU 1 memory slots Symmetry is best for memory performance on 2 CPU systems e g 4 GB should have 2x1GB on CPU 1 memory slots and 2x1GB CPU 2 memory slots While 5 GB would run 2x1GB on CPU 1 2x2GBMB on CPU2 it will experience slower memory performance XATO Configuration Notes Availability August 2007 1 XATO allows the configuration of systems to exact customer requirements This provides the customer with a fully tested and configured system that requires little if any additional configuration prior to deployment All XATO orders require a working configuration A minimum of one CPU option required Single processor systems can be expanded with a second CPU of the identical model speed
46. nvestment protection amp SUN microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 5 Key Messages The Netra X4200 M2 server delivers dramatic performance and flexibility along with space and power efficiency to meet the increasing demands of the network infrastructure Powered by up to two dual core Next Generation AMD Opteron embedded class processors the Netra X4200 server achieves extreme performance while it s high compute density and low power consumption address constraints related to space power and cooling The Netra X4200 server allows Sun to continue to offer customers choice and flexibility simplicity durability and compatibility CHOICE and FLEXIBILITY Supporting the Solaris Operating System OS Linux and Windows operating systems the Netra X4200 M2 server enables customers to run existing 32 bit x86 OS and applications on the same hardware as they migrate to a wide selection of Next Generation 64 bit operating systems and their choice of applications Customers can standardize on one hardware platform for all major operating systems in their network The Netra X4200 M2 is the first Netra 2U rack server to offer the choice of four internal hard drives with no DVD or two internal hard drives with DVD giving customers the maximum flexibility for storage capacity SIMPLICITY Ease of serviceability and Administration The Netra X4200 M2 was desi
47. ompared to competing operating systems It offers many innovative technologies that fundamentally change the equation for organizations needing to reduce costs reduce complexity and minimize risk The new features in the Solaris 10 OS bring mainframe quality software to even the smallest single processor servers and provide a stepping stone into tomorrow s data center For CIOs and Line of Business Managers who are dissatisfied with high infrastructure costs and security vulnerabilities in their workgroup server environments the Solaris 10 OS on x64 brings a proven enterprise class OS at 1 11 the cost of Microsoft and 20 60 off the cost of Red Hat over three years The Solaris 10 OS is designed to help organizations optimize system utilization levels deliver extreme performance and provide virtually unparalleled security all with relentless around the clock availability Optimal Utilization of computing systems is a priority for IT managers where server consolidation is a common approach and is improved in the Solaris environment by Solaris Containers enable as much a 4x increase in system utilization by helping to efficiently and securely support thousands of applications per system Highly configurable Solaris Containers can dynamically adjust system resources to business goals within and across Containers with the added benefit of isolating applications from each other and from system faults so a problem in one applicati
48. on For example X7800A is the field installable option while part number 7800A with the X removed is used only when the part will be installed at the factory ie Assemble to Order SG XARY030A AMD Opteron 2000 HE Series Next Generation AMD Opteron Model 2214 HE 2 2 GHz Dual Core 68 W August 2007 Memory X 4225A Z 2 GB Registered DDR2 667 kit 2 x 1GB X 4226A Z 4 GB Registered DDR2 667 kit 2 x 2GB X 4227A Z 8 GB Registered DDR2 667 kit 2 x 4GB Internal Storage Devices XRA SS2ND 146G10KZ 146 10000 rpm 2 5 inch SAS disk drive RA SS2ND 146G10KZ 146 GB 10000 rpm 2 5 inch SAS disk drive for factory integration only CRS 4354A Z Disk bay filler panel for Netra X4200 M2 x64 August 2007 server XATO and FACTORY INTEGRATION ROHS 5 Internal Media Devices X 4356A Z Slimline DVD RW 4355A Z DVD Bay Filler Panel Netra X4200 M2 x64 August 2007 server XATO and FACTORY INTEGRATION ROHS 5 Racks SR900 38 Sun Rack 900 38 alloy SR900 36N Sun Rack 900 36N alloy SR1000 38 Sun Rack 1000 38 alloy SR1000 42 Sun Rack 1000 42 alloy Sun StorEdge 72 inch expansion cabinet Sun Fire cabinet Rack Kits X7901A 4 X7902A 4 X7904A 4 X 8099A 4 19 inch 2 post rackmount kit 23 inch 2 post rackmount kit 600mmx600mm rackmount kit 19 inch 4 post slide mount kit Miscellaneous options X949A 4 X4234A Z Wago DC plug connectors 10 pack Air Filter 10 pack for 2 HDD v
49. on cannot affect the system or other applications Solaris ZFS File System zetabyte file system integrates devices storage and file systems structures into a single structure simplifying file system management and providing a reliable and flexible solution that can help reduce cost complexity and risk Extreme Performance is delivered with optimization for the latest UItraSPARC R AMD Opteron and Intel Xeon processors as well as Dynamic Tracing DTrace designed for use live use in production situations is a powerful tool for analyzing and diagnosing elusive problems and increasing system performance It is non invasive and has no system overhead when not in use but with its pervasive coverage root cause for intermittent system problems can be found quickly and performance gains in real world applications have been optimized to run as much as 30 times faster A Unified TCP IP Stack where the TCP and IP layers are partially merged delivers a 30 to 50 percent improvement in network throughput with a 10 to 15 percent lower CPU load than previous Solaris OS versions Unparalleled Security continues to be a focus as Solaris 10 OS adds significant features that can help defend against attacks by preventing unauthorized access to data and applications with Process Rights Management replaces the traditional UNIX R platform s all or nothing root mechanism with a fine grained set of privileges for control over the res
50. only e g AMD Opteron 1x2214 HE embedded class processor based system can only use another AMD Opteron 2214 HE embedded class processor A minimum of one memory option per CPU required Memory must be installed in pairs Pairs of different densities may be mixed e g 2X1GB and 2x2GB on CPU 1 memory slots Symmetry is best for memory performance on 2 CPU systems e g 4 GB should have 2x1GB on CPU 1 memory slots and 2x1GB CPU 2 memory slots While 5 GB would run 2x1GB on CPU 1 2x2GB on CPU2 it will experience slower memory performance A fully configured 32 GB system requires two CPUs Only 16 GB memory is possible in a single CPU system Example A single CPU system can utilize up to 2 memory options 4 DIMMs total for a maximum of 16 GB The unpopulated second CPU socket prevents the use of the second memory bank 4 DIMM slots A disk filler panel is required for any HDD slot not filled DVD filler panel is required when selecting the N87 AD Z or the N87 AA Z chassis amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 39 Upgrades Upgrade Paths Netra X4200 M2 servers are eligible for the Sun Upgrade Advantage Program UAP Through this program customers can trade up their current Sun or non Sun severs for a new Netra X4200 M2 server and receive a trade in allowance that is applied as a percentage off of the list price on the new Netra X4200 M2 server Cu
51. orted Up to two hot pluggable hard drives with DVD or up to four hot pluggable hard drives with no DVD Hardware RAID 0 1 striping and mirroring Two redundant hot swappable AC or DC power supplies Built in quad Gigabit Ethernet ports provide redundancy Environmental monitoring Easy access for most component replacements Dry Contact Alarms enable Telco operators to use a relay to signal fault conditions to a rack or control room panel as well as an alarm monitoring system amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 24 Operating Systems Netra X4200 M2 Server Operating Systems A world class performance platform the 64 bit Netra X4200 M2 server allow customers to run the operating system that best fits their needs With a multitude of operating systems fully supported and or certified the Netra X4200 M2 server provides customers with more choices within the same hardware architecture than competing servers in its class Supported Operating Systems The Netra X4200 M2 Server supports Solaris 10 beginning with Solaris 11 06 In addition to Solaris the Netra X4200 M2 server support Linux and Windows starting May 2007 Linux and Windows Operating systems support is leveraged from the Sun Fire X4200 M2 server more information on the latest Linux and Windows OS support for the Netra X4200 M2 Server can be found on the following website link http www s
52. ources and objects that processes can manipulate Solaris Cryptographic Framework library secures data flows by providing a set of programming interfaces for application level and kernel level cryptographic operations allowing developers to utilize highly optimized cryptographic algorithms and providing transparent access to the same hardware encryption acceleration devices used by the operating system kernel Relentless Availability Expected in a Solaris OS environment predictive self healing technologies provide new levels of application availability with AS amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 26 Solaris Fault Manager proactively handles system problems by removing components before failure CPU memory and I O problems are diagnosed and corrected before they can cause downtime Solaris Service Manager manages application software running on the system monitoring applications and restarting entire application trees if necessary Compatibility Same OS Low End to High End Systems The Solaris OS is built from a single source base and optimized to run on multiple platforms providing customers with the same best of breed OS on SPARC Opteron AMD64 64 bit and x86 32 bit processor platforms Solaris Application Guarantee Program This program guarantees binary compatibility between versions of Solaris OS on each platform and has been exte
53. provide customers freedom to choose solutions that best meet their business needs Sun supports the Microsoft Windows operating environment on select new Sun x64 systems The ability to run Solaris Microsoft Windows or Linux software on Sun x64 servers and workstations allows customers to use a single vendor to meet a wide range of requirements Sun s support for multiple operating systems enables customers to deploy their choice of operating system without having to change hardware platforms when their requirements change This helps reduce the cost and complexity required to support and manage multiple vendors in turn helping to increase return on investment while reducing risk amp Sun microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 28 System Management Sun Integrated Lights Out Manager ILOM Sun Integrated Lights out Manager is driven by an integrated system service processor that follows x86 standards and is different from SPARC R technology based system remote management solutions It provides for full remote KVMS Keyboard Video Mouse Storage support together with remote media functionality Lights out management LOM is achieved using an on board independently powered service processor with its own robust security hardened OS ILOM provides remote administration via an intuitive browser based GUI DTMF CLI remote console SNMP v1 v2c v3 or IPMI v2 0 protoco
54. rade to 3 year Sun Windows Gold Support for Netra X4200 M2 Server W9D N87W 3P Upgrade to 3 year Sun Windows Platinum Support for Netra X4200 M2 Server AS amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only 44 Warranty Upgrade to Sun HW Only Service for Netra X4200 M2 W9D N87 SD 1H Upgrade to 1 year Sun HW Only SBD for Netra X4200 M2 Server W9D N87 SD 2H Upgrade to 2 year Sun HW Only SBD for Netra X4200 M2 Server W9D N87 SD 3H Upgrade to 3 year Sun HW Only SBD for Netra X4200 M2 Server W9D N87 24 1H Upgrade to 1 year Sun HW Only 7 24 with 4 hour response for Netra X4200 M2 Server W9D N87 24 2H Upgrade to 2 year Sun HW Only 7 24 with 4 hour response for Netra X4200 M2 Server W9D N87 24 3H Upgrade to 3 year Sun HW Only 7 24 with 4 hour response for Netra X4200 M2 Server W9D N87 22 1H Upgrade to 1 year Sun HW Only 7 24 with 2 hour response for Netra X4200 M2 Server W9D N87 22 2H Upgrade to 2 year Sun HW Only 7 24 with 2 hour response for Netra X4200 M2 Server W9D N87 22 3H Upgrade to 3 year Sun HW Only 7 24 with 2 hour response for Netra X4200 M2 Server AS amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use Only 45 Chipkill ECC PCI E PCI X SAS Ethernet 10 100 1000Base T IKE I O IPSec IPMI L2 cache MTBF SNMP Just the Facts August 2007 Glossary A technology
55. rastructures The Netra X4200 M2 reaffirms Sun s commitment to customers who invested in the Netra product line by offering a product that delivers enhanced performance throughput consistent form fit and function Key Product Features Functions and Benefits Next Generation AMD Opteron Processors Native dual core design Delivers both 32 and 64 bit enterprise class computing Common socket design for Next Generation and Quad Core AMD Opteron processors AMD Direct Connect Architecture AMD Virtualization Technology Nearly doubles computing resources without power and cooling increases Increases performance while providing investment protection for existing 32 bit application Reduces data center churn as upgrade for increased performance Integrated Memory Controller improves performance by more effectively handling the memory AMD s Direct Connect Architecture helps guests run at near native speed HyperTransport Technology and Integrated 128 bit wide DDR2 Memory Controller Provides a high speed connection between processor and core logic Integrated controller pools memory resources onto a single coherent space Eliminates performance bottlenecks found in traditional x86 Front Side Bus FSB architectures Reduces power requirements of server chip by eliminating the need for a separate memory controller chip Reduces memory bandwidth latency AMD Opteron Processors Consistent processor the
56. rmal power window requirements across all generations Integrated Memory Controller PowerNow Technology dynamic processor voltage and frequency throttling technology which works with server BIOS and operating system Networks using Next Generation AMD Opteron based servers should experience less churn during performance upgrades as processor power requirements are planned not to increase AMD Opteron processors do not require an additional memory controller chip When running OS s supported by this product for PowerNow technology power consumption is minimized DDR2 Memory Proven cost effective technology DDR2 memory has been in the marketplace for years and requires less power than FBDIMM memory Just the Facts August 2007 AS amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only 7 DDR2 667 memory with ECC ECC helps to ensure data integrity with automatic error correction in case a single bit is affected by such events as alpha particle hitting a memory cell Increases memory reliability helping to reduce the chances of system downtime caused by memory failures Hardware RAID support provided by the onboard disk controller Supports either two disk RAID 1 Integrated Mirror volumes or two three or four disk RAID 0 Integrated Stripe volumes Provides data redundancy and increased performance at no additional cost NEBS Lev
57. rrent 6 5A at 100 to 120 VAC 3 2 A at 200 to 240 VAC 12 7A at 48VDC 10 2A at 60VDC Maximum heat dissipation 2150 BTU hr 2085 BTU hr Just the Facts August 2007 amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only 32 Description AC Specification DC Specification Nominal Power Estimated 475 W Estimated 475 W Acoustic Noise Emissions These are the acoustic noise emissions of a Netra X4200 M2 server Declared noise emissions are in accordance with ISO 9296 standards Description Mode Specification LwAd 1 B 10 dB Operating acoustic noise 7 0B Idling acoustic noise 7 0B Agency Compliance Specifications The Netra X4200 M2 server complies with the following specifications Category Relevant Standards Safety UL CSA 60950 1 EN60950 1 IEC60950 1 CB Scheme with all country deviations TEC825 1 2 CFR21 part 1040 CNS14336 GB4943 Ergonomics EK1 ITB 2000 RFI EMC EN55022 Class A KSC 5858 Class A 47 CFR 15B Class A GB9254 Class A ICES 003 Class A EN61000 3 2 VCCI Class A GB17625 1 AS NZ 3548 Class A EN61000 3 3 CNS 13438 Class A Immunity EN55024 TEC 61000 4 5 IEC 61000 4 2 61000 4 6 IEC 61000 4 3 IEC 61000 4 8 TEC 61000 4 4 61000 4 11 Telecommunications EN 300 386 Telecordia SR 3580 NEBS Level 3 Regulatory Markings CE FCC ICES 003 C tick VCCI GO
58. s Max memory 32 GB 32 GB Max internal disk drives Up to two 146 GB w DVD or four 146 GB w o DVD 2 5 SAS HDDs hot swappable with support for Striping Mirroring HW RAID 0 1 Up to two 73 146 GB w DVD or four 73 GB w o DVD 2 5 SAS HDDs hot swappable with support for Striping Mirroring HW RAID 0 1 Graphics Controller ATI Rage XL ATI Rage XL VO Tray Load DVD RW int Two USB 1 1 ports Tray Load DVD CD RW or DVD RW int Just the Facts August 2007 amp SUN microsystems Sun Confidential Internal and Sun Channel Partners Use Only Feature Netra X4200 M2 Server Sun Fire X4200 M2 Server Four USB 1 1 ports Processor PCI Three PCI X slots full height 2x full Four PCI E slots MD2low profile length 1x half height One PCI X slot MD2 low profile One PCI E slot MD2 low profile Ethernet Four on board Gigabit ports Four on board Gigabit ports Power supplies Two 550W hot swap AC DC 1 1 Two 550W hot swap AC DC N 1 redundant redundant Form factor 2 RU x 20 2 RU x 24 8 Integrated Service Yes IPMI 2 0 Yes IPMI 2 0 In band management IPMI v2 0 via KCS driver SNMP OS resident agent IPMI v2 0 via KCS driver SNMP OS resident agent Out of band management IPMI v2 0 DMTF CLI SNMP v1 v2 v3 Web GUI IPMI v2 0 DMTF CLI SNMP v1 v2 v3 Web GUI Remote management featuresRemote
59. stomers can trade in their old systems in on a 1 for 1 server basis or consolidate many servers Sun Upgrade Allowance Program Sun UAP Since August 29 2000 Sun has offered customers a simple flexible and easy to understand way of ordering server storage or Desktop upgrades The Sun UAP program works on a percentage based upgrades model This new model simplifies the upgrades process by providing a trade in value as a percentage allowance This percentage allowance can then be applied to the list price of a regular Sun system configuration Under the Sun UAP program allowance codes or part numbers have been created and the percentage allowance is built into this part number see below Allowance codes can be found in the Sun Pricebook starting with the September 2000 version Note that allowance codes apply to configured systems Allowance Code Numbering Scheme Below is an example allowance code along with a breakdown of the components Allowance code ALW 10 S L N87 ALW Upgrade identifier All allowance codes start with ALW 10 Allowance percentage Percentage is applied to the list price of a standard marketing part number 10 means 10 off of list price 08 means 8 off of list price and so on Note Any other discounts such as volume discounts should also be taken off the list price and not the net of the above T Desktop upgrades S for server upgrades and D for storage upgrades L In
60. t support Solaris Support for PowerNow Solaris Engineering is currently aggressively working to add PowerNow support Solaris is targeting a patch to add support at the end of this calendar year PowerNow support is targeted for the Solaris 10 Update 4 release planned to be released in Jan Feb 2007 For more information on AMD PowerNow see http enterprise amd com us en Technology PowerManagement AMD Virtualization Technology ia ae 22 _ CNW E f E Application hf Application gt m 8 sid ossa N f ze DN Guest OS E v xe a 2 f k Virtual Virtual q E i Guest OS Machine Machine F lt Hypervisor Host OS j uw Virtualization Instructions Virtualization enables data centers to achieve higher levels of efficiency utilization and flexibility by dividing a computer into several virtual machines or consolidating many systems onto one virtual machine Hardware enabled AMD Virtualization offers Reduces complexity of virtualization software by adding instructions to the hardware Reduces overhead by selectively intercepting information destined for guest OS s Enables simpler implementation and support by allowing guest OS s to run unmodified Improves security of virtual machines by increasing isolation of host and guest OS s Improves efficie
61. tion is disabled the ILOM WDT will be set by initial BIOS code execution to a configurable timeout threshold If this time limit expires before the OS can boot start critical services and the application begins to reset the timer the ILOM can be configured to reset or power off the host server generating an alert for remote management Standardized IPMI management interfaces will be provided to the user application to configure and reset the ILOM watchdog function final implementation plan is TBD amp Sun microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 30 Specifications Processor Options Processor One or two Next Generation AMD Opteron Processor 2000 HE Series embedded class Dual Core 2214 HE 2 2 GHz Cache 1 MB Level 2 Main Memory 4 DIMM slots per CPU socket Registered DDR2 667 ECC DIMMs 128 bit plus ECC databus total 8 DIMM slots System configurations from 2 GB up to 32 GB maximum of 16GB for single processor systems Standard Integrated Interfaces Network Four 10 100 1000Base T Ethernet ports Network management One 10 100Base T Ethernet port Serial management One TIA EIA 232 F asynchronous RJ45 Port Video One vide port HD 15 SAS Four channel SAS interface internal access only USB Two USB 2 0 ports Rear Expansion bus Three full height internal 64 bit 133MHz PCI X slots 2x full
62. tures of the Single and Dual Core AMD Opteron formerly known as Rev E processors including 64 bit operating systems to provide full transparent and simultaneous 32 bit and 64 bit platform application multitasking Direct Connect Architecture Addresses and helps reduce the real challenges and bottlenecks of system architecture Memory is directly connected to the CPU optimizing memory performance T O is directly connected to the CPU for more balanced throughput and I O CPUS are connected directly to CPUS allowing for more linear symmetrical multiprocessing ntegrated DDR2 Memory Controller A 128 bit wide on chip DDR2 memory controller that supports ECC and ChipKill technologies and provides low latency memory bandwidth which scales as processors are added AMD HyperTransport Technology Provides a scalable bandwidth interconnect between processors I O subsystems and other chipsets Dedicated 1MB L2 Cache for each core 24 GB s 10 7 GB s 1000MHz DDR2 667 id DDR2 Integrated HyperTransport HyperTransport Memory Controlle Technology Crossbar System Request Interface AMD64 Core 1 AMD64 Core 2 PowerNow PowerNow AMD Virtualization AMD Virtualization 1MB 1MB L2 Cache L2 Cache Figure 1 Next Generation AMD Opteron Processor Design for Socket F 1207 AS amp SUN microsystems Just the Facts August 2007 Confidential Internal and Sun Channel Partners Use On
63. un com servers netra x4200 os jsp Firmware and Drivers For more information on the latest firmware and drivers for the Netra X4200 M2 Server can be found on the following website link weblink coming soon Supported I O Cards Please refer to the Options section of this document for a complete list of I O cards that have been NEBS tested for the Netra X4200 M2 sever For specific Linux and Windows support for these cards please refer to the following website as this is being leveraged from the Sun Fire X4200 M2 Server http www sun com servers entry x4200 optioncards jsp Supported Storage and Associated HBAs Since the external storage systems support is leveraged from the Sun Fire X4200 M2 server more information for the Netra X4200 M2 Server can be found on the following website link For the latest supported storage and assocated HBAs http www sun com servers entry x4200 storage jsp Please note that not all HBAs listed on the above website has been NEBS tested Please refer the Options section of this document for a complete list of HBAs that have been NEBS tested amp SUN microsystems Just the Facts August 2007 Sun Confidential Internal and Sun Channel Partners Use Only 25 Solaris 10 OS The most advanced operating system on the planet Key Messaging In a class by itself the Solaris Operating System is a significant leap forward form the Solaris 9 OS establishing it in a class by itself when c
64. ximizing Java technology performance benefits and stretching customers application investments by creating a common application engine Linux and Java platform integration Alliances with Red Hat and SUSE Linux to distribute Sun s latest Java Virtual Machine JVM TM machine included as part of the OS distributions The JVM software technology allows the Java 2 Software to host applications on any computer or operating system without rewrite or recompile Pricing Support Subscriptions are available with or without media CDs manuals levels of support provide access to either Red Hat Network or SUSE s Linux Portal During the support period if any new versions of SLES or RHEL for AMD64 are made available users with current support entitlements have access to those new versions from the maintenance sites of Red Hat and SUSE Please see the Services section for more details Windows OS The Netra X4200 M2 Servers will support the Microsoft Windows Server 2003 Enterprise and Standard Edition operating systems in May 2007 Sun System Service Plans will be available from Sun Microsystems at an additional charge Please see the Services section for more details Please bookmark and refer to the following Windows on Sun sites for frequently updated information External http www sun com software windows Internal https onestop central sun com windows Key Messaging Flexibility for Sun s Heterogeneous Customers To

Download Pdf Manuals

image

Related Search

Related Contents

Client Information Pack Western Australia  Philips CP9948  V-Twin Mfg. Daniel Boone Forward Control Kit W/Master Cylinder  APCUPSD User Manual  WordStat 6 - Provalis Research  Edge Performance Chips Installation Instruction  Desa TSTPEA-A Indoor Fireplace User Manual  Benutzerhandbuch - Barudan America  Yamaha 2010 V Star Custom Owner's Manual  Wiley Mac mini Hacks & Mods For Dummies  

Copyright © All rights reserved.
Failed to retrieve file