SERVICE MANUAL
Contents
1. Hour counters Two digital hour counters are built into the control system Function Keys O ON OFF Press once to turn the unit ON or OFF e PURGE Press the PURGE key to empty water from the pump reservoir During normal operation the pump purges automatically when the reservoir is full Use PURGE before moving the machine to avoid water spillage The pump will automatically stop after forty seconds of continuous operation O 1 Press and key to adjust the humidity set point within the range of 26 and 90 1 1 When adjusting the humidity set point the unit will not operate until the set point is lower than the actual humidity reading and the display will read completed The unit will resume operation after the actual humidity reading is higher than the set point 1 2 When the set point is adjusted to below 26 the unit will run on continuous dehumidify mode The display will read CO for continuous operation 1 3 In the event of a power loss the humidity set point is held in the system memory The unit will restart once power is restored If the unit fails to memorize the previous humidity setting the PCB battery may need to be replaced 2 Band keys are used to adjust the time 3 Band keys when pressed AT THE SAME TIME will switch menu functions e Press the function key The panel will display Humidity setting Timer Clock Language ID USB SD CARD and GSM Press to select any of th
2. and re charge the refrigerant 3 Replace display panel PCB Water pump fault or blockage Flashes every 1 second 1 Water pump is damaged 2 Debris in water pump Replace or clean the water pump Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc TROUBLESHOOTING GUIDE The PCB and or fuse is blown Check the PCB and fuse replace as 1 Dehumidifier does not necessary start Both Poor plug contact at outlet Re insert plug into outlet or replace outlet compressor and fan Wire disconnected or loose Look for loose wire and reconnect Refer to motor do not circuit diagram for terminal identification operate Repair or replace any loose terminal Capacitor failure Test capacitor Replace if not within 10 Discharge capacitor before of manufacturer s rating Replace if shorted testing open or damaged Check the wire connections if loose repair or replace the terminal If the wires are disconnected refer to wiring diagram for Wiring problem identification and replace the wires Check the wire connections if not according to the wiring diagram correct the connections 2 Fan motor runs but Capacitor Check the capacitor Replace if not within compressor does not Discharge capacitor before 10 of manufacturer s rating Replace if run servicing shorted open or damaged Check the compressor for open circuit or Compressor ground If open or grounded rep
3. 4 Re install all items above 11 4 Replacing the temperature and humidity sensors The Temp Humidity Sensor may be removed without removal of the PCB or rear cover if you are careful when you disconnect and reconnect the leads from the PCB STEP 1 Take off the front housing and control panel STEP 2 Remove two 2 screws securing the sensor to the front of the evaporator coils STEP 3 Disconnect wire for the temperature and humidity sensors from the PCB STEP 4 Replace the temperature and humidity sensor STEP 5 Re install control panel housing etc 11 5 Replacing the fuse of PCB WARNING When replacing the fuse be sure to use only a fuse of the same rating ampere rating is 6 3A STEP 1 Take off the front housing to access fuse and PCB STEP 2 Remove two 2 screws to take apart main PCB cover STEP 3 Take apart fuse cover and replace fuse STEP 4 Replace the fuse of main PCB STEP 5 Reassemble 19 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 11 6 Re charging the refrigerant NOTE If refrigerant gas is lost from the machine it may be necessary to use a Qualified Refrigeration Technician to correct the problem Contact Ideal Air Support for more information STEP 1 Take off the front housing STEP 2 Find the source of the leak and repair using specific refrigerant grade solder STEP 3 Locate the pinch off tubes see picture below and solder
4. Next step is to check the start capacitor 4 If all of these checks do not identify faulty components the compressor will need to be replaced Contact Ideal Air Support for next steps 11 8 Replacing the capillary tube When one or both of the capillary expansion tubes is blocked you will see that only half of the evaporator coils is freezing Upon closer inspection you may notice that icing present on one of the capillaries tubes Failure of the capillary tube can be confirmed by the following procedure NOTE an experienced refrigeration technician is required 1 Take off the capillary tubes and drain out any refrigerant present 2 Introduce pressurized air into the tube to clean out the capillary tube further If air does not pass through the capillary tubes one or both are blocked and need to be replaced 3 Contact Ideal Air Support for next steps 21 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 12 SERVICE PARTS LIST ME ji e n e 22 13 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc LIMITED WARRANTY PARTS ONLY INCLUSIONS ITEMS COVERED BY WARRANTY The following items are covered by the warranty 1 The period ofthe warranty on this product is one year which begins from the day of purchase To qualify the owner of the product must provide a copy of the sales receipt showing the date of purchase In the absence
5. of a sales receipt Ideal Air will use the date of manufacture which is found on the unit as the start date of the warranty This warranty is for PARTS ONLY Ideal Air will help provide technical support to the end user over the phone to help with diagnosis of problems Ideal Air will provide any needed replacement parts for a period of one year from the date of purchase This warranty covers defect of materials and components only EXCLUSIONS ITEMS NOT COVERED BY WARRANTY The following items are not covered by the warranty 1 2 End user dissatisfaction will not be a cause for return under this warranty Failure to adhere to and or comply with user s manual instructions will void all associated warranty obligations Damage that occurs during transportation Any damage or improper repairs including misuse negligence and insufficient maintenance Damage caused by force majeure Damage to wheels which are easily broken by improper usage Ideal Air will not be responsible for the following for any warranty claim a Pickup or delivery of the equipment for repair by Ideal Air or other authorized facility b Rental of replacement equipment during any repair period c Products which have been declared a total loss and then refurbished and resold d 3 party Technician charges including travel time or mileage labor and materials e This Limited Warranty is for Parts Only Labor cost is not covered in our warranty Notices of Users
6. on service valves STEP 4 Connect a vacuum pump and evacuate refrigerant system for 20 to 30 minutes until 15Pa 30Pa of vacuum are obtained STEP 5 Charge the system with the refrigerant charge listed on the rating label found on the side of the unit Step 6 Reassemble Gas delivery ports A EVAPORATOR ASSEMBLY LOW PRESSURE SIDE COMPOUND GAUGE EXTERNAL VACUUM PUMP Yi MANIFOLD LO C GAUGE AY B NI NT CHARGING CYLINDER 20 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc Gas circuit diagram REFRIGERANT CIRCUIT DIAGRAM FOR AIDER CONDENSER a O lt L a O a L gt iu CAPILLARY GAS DIRECTION IN COOLING GAS DIRECTION IN DEFROSTING 11 7 Replacing the compressor The compressor used in the dehumidifier is durable and should last for many years without failure or need for service In the unlikely event of compressor failure the compressor can be replaced by competent refrigeration technician Failure of the compressor can be confirmed by the following procedure 1 If the compressor does not run check that power is reaching the compressor with a volt meter 2 If power is reaching the compressor check that the thermal overload switch is functioning properly Reset as necessary and check for normal operation 3
7. that the power cord to the machine has been disconnected before disassembly 9 1 Disassemble front housing 1 Remove six 6 outside hexagonal screws to take the front housing off of the unit Tool Outside hexagonal screw sleeve 9 2 Disassemble back housing and control panel see pictures below STEP 1 Remove the nuts from the axel on each wheel hub Remove wheels from unit STEP 2 Place a support under the unit after removing each wheel to avoid tilting the unit STEP 3 Remove the four 4 screws holding the screen and panel in place Remove label STEP 4 Remove two 2 screws attaching to PCB to panel Pull out lead wire from the PCB STEP 1 STEPS 3 amp 4 STEP 5 see below Remove seven 7 screws to remove the back housing from the unit x H Fresa ji li n View after removing the back housing Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 10 ROUTINE MAINTENANCE WARNING Ensure that the power cord is unplugged from the power outlet before performing routine maintenance IMPORTANT To ensure continued efficient operation of the dehumidifier the maintenance procedures below should be performed regularly 10 1 Frequency of maintenance The working performance of the dehumidifier will be greatly reduced if the filters become clogged Please clean
8. Responsibilities Regarding the Ideal Air Warranty 1 It is the users responsibility to maintain the equipment in accordance with the instructions provided in the User s Manual We recommend that you keep records pictures amp descriptions and receipts you may be asked to prove that the maintenance instructions have been followed It is the user s responsibility to operate the equipment in a safe manner and for the use in which it was intended If a defect in materials or workmanship occurs it is your responsibility to cease operating the equipment until repairs can be made Damage which occurs from continued operation may not be covered by this warranty 23
9. SERVICE MANUAL IDEALair COMMERCIAL GRADE CG2 Commercial Grade Dehumidifier SLS Part Number 700899 IMA YWI TAL a YAN NATY Ky Di o a 10 11 12 13 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc Contents Precautions 1 1 General Precautions 1 2 Warnings 1 3 Installation Precautions 1 4 Operational Precautions Functions 2 1 Control 2 2 Defrost function Performance curves Specifications Parts Drawings 5 1 Outside component drawing 5 2 Internal component drawing Circuit Diagram Error Codes Troubleshooting Guide Disassembly Instructions 9 1 Disassembly of front housing 9 2 Disassembly of rear housing and wheels Routine Maintenance 10 1 Cleaning the Air Filter 10 2 Replacing the Battery 10 3 Checking wiring connections 10 4 Cleaning evaporator surface 10 5 Checking the refrigerant charge Repair Instructions 11 1 Replacing the water pump 11 2 Replacing the motor 11 3 Replacing the PCB 11 4 Replacing the temperature and humidity sensor 11 5 Replacing the fuse of main PCB 11 6 Re charging the refrigerant 11 7 Replacing the compressor 11 8 Replacing the Capillary tube Service parts list Warranty Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 1 PRECAUTIONS 1 1 General Precautions To prevent injury to the user other people and or property damage the instructions shoul
10. d be followed Incorrect operation may cause harm or damage to people and or property Before servicing this unit you must read this service manual 1 2 Warnings Always check for gas refrigerant leakage after installation and or repair of product Low refrigerant levels may cause significant product failure Tip look for oil drips or oil stains on or near the unit This indicates a leak in the refrigerant system Securely install the drain hose to ensure that water is properly drained away from the unit To avoid injury use two or more people to lift and transport the product Operate dehumidifier in an upright position only When transporting the dehumidifier on its side allow the dehumidifier to stand upright for 30 minutes before switching ON This is necessary to allow the refrigerant system to stabilize and avoid system damage After removing the dehumidifier from its shipping container visually check for signs of damage If there is evidence of damage do not operate Call the store you purchased the unit from to discuss next steps Do not discard packing manuals or any contents Original packaging and materials are required for any product return Do not disassemble or repair the product while plugged in 1 3 Installation Precautions Please follow these warnings during installation to prevent risk of fire or electrical shock Do not use a defective or underrated electrical circuit For electrical work consider contact
11. ese sub menus Repress Okey the appliance will return to main menu oress the ENTER key to confirm menu selection Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc Note The following are OPTIONAL and non supported functions Language ID USB SD CARD and GSM Your system may not have these options available If your system does have these options it may not function Please understand these options are not supported by Ideal Air Technical Support and any error message can simply be ignored More detailed operational instructions please see the OWNER S MANUAL 2 2 Defrost Function The Ideal Air CG2 Dehumidifier is fitted with a temperature sensitive defrost control The defrost control device is designed to prevent ice buildup at lower operating temperatures In some conditions the defrost device may not be able to remove all ice from the evaporator coil In these cases the fan may stop running to shut down air movement to enhance the performance of the defrost mode In situations where year round humidity control is desired the dehumidifier unit will have to operate across a wider range of temperatures The unit is programmed to restrict defrost operation to the times when ambient temperature falls below 75 degrees F The defrost control sequence is as follows NOTE Te Ambient Temperature 1 When Te is less than 32 F and greater than 105 F the compressor and fan motor stop will sto
12. ing a qualified electrician or mechanical technician Always use an electrical plug that is grounded Always install on a dedicated circuit Use the correctly rated breaker fuse or other over current protection appropriate to the unit as specified by local electrical code Do not modify or extend the power cable Be careful when unpacking and installing the product Sharp edges could cause injury Be especially careful of the enclosure edges and the fins on the refrigerant coils Do not install the product in a manner that could allow it to fall over f this unit falls over it increases risk of injury or damage Take care in placing locating the unit to prevent power cord from being forcefully pulled out or damaged during operation Do not place anything on the power cable Do not use if the power cable becomes damaged Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 1 4 Operational Precautions Please follow these warnings when operating the dehumidifier to ensure safe and effective operation Do not plug in or unplug the power supply while the unit is operating Do not place a heater or other appliance near the power cable Do not store or use flammable or combustible products near the product If a flammable gas leak occurs ensure gas is off and open a window for ventilation before turning the product on Do not turn switches on or off There is risk of explosion or fire If strange sounds
13. lace the compressor Check the compressor O L P if externally Overload protector O L P mounted Replace if open If the compressor temperature is high remove O L P cool and retest Check room humidity with hygrometer Room air is dry Increase room temperature Room temperature is too low This unit is designed to be operated at temperatures above 41 F Make sure there are no curtains blinds or 3 Dehumidifier does not Airflow is restricted furniture blocking the front or back of the dry the air as it dehumidifier should Doors and windows may Check all doors windows and other not be closed tightly openings to ensure they are securely closed to prevent moisture from re entering room Fan motor is not operating Check fan motor repair or replace it Check if the air filter is Clean the air filter clogged with dust 13 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc Check if the unit is securely Set and use the dehumidifier at a sturdy positioned flat and level place If cracked out of balance or partially 4 Loud noises during missing replace it operation Internal compressor noise Replace compressor Loose screws somewhere in Find loose screws and tighten them the unit Worn bearings in fan motor If knocking sounds continue when assembly running or if shaft is loose replace the motor If noise continues or if noise appears to be outside the moto
14. leaning the surface of the evaporator With the filter removed inspect the evaporator coils for build up debris dust lint etc If debris is visible cleaning is needed as follows STEP 1 With the Filter removed remove four 4 screws from the filter cover and set cover aside Now the evaporator coil will be accessible STEP 2 Using a soft brush and a vacuum cleaner gently clean away the accumulated debris from the evaporator coil STEP 3 Re install the Filter Cover and the Filter WARNING DO NOT STEAM CLEAN REFRIGERATION COILS OR USE HARSH CHEMICALS 10 6 Check for indication of low refrigerant charge STEP 1 Disassemble the front housing refer to section 9 1 STEP 2 Run the unit for 15 minutes and briefly remove the cover STEP 3 Inspect the evaporator coil Look for frost evenly coating the evaporator surface this indicates a normal charge At temperatures above 68 F the coil may be covered with droplets of water rather than frost If partial frosting of condenser and frosting of the thin capillary tubes is present this indicates low refrigerant charge Contact Ideal Air Support for help adding refrigerant gas to the unit IN THE EVENT OF LOW REFRIGERANT CHARGE STOP USING THE UNIT TO PREVENT PERMANENT DAMAGE 17 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 11 REPAIR INSTRUCTIONS WARNINGS In the event of failure of an electrical component contact Ideal Air Sup
15. p working 2 When Te is between 32 F and 75 F 2 1 Continuous Operation run time is equals to Te x 2 The minimum run time is 30minutes 2 2 If temperature of indoor coil is less than or equal to 26 F with detection continuously for 30 seconds or more after continuous operation run time is reached the unit will automatically enter defrost mode 2 3 Defrost mode begins with energizing the four way valve 30 seconds later the compressor will begin operation The fan motor will not operate during defrost The compressor will run for 2min After this time the four way valve will close 30s later the compressor and fan motor will return to normal operation 2 4 If temperature of indoor coil is greater than or equal to 26 F after continuous operation run time is reached the unit will not enter defrost mode 2 5 IfTe gt 75 F the unit will NOT enter defrost mode Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc ADDITIONAL WARNINGS RELATING TO REFRIGERATION COMPONENTS Due to the high pressures within the refrigeration circuit under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove ice buildup No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and the presence of refrigerant gases If power supply is lost to the unit it must be allowed to stand by for at least three minutes before restarting Failure to do so may cau
16. port to obtain the correct replacement part Ensure that the power cord to the machine has been disconnected before repairing 11 1 Replacing the water pump 1 If the water pump does not work please take off the front housing 2 See the picture below and remove two 2 screws 3 Remove drain tubes connected to the water pump 4 Remove the pump cover disconnect the pump and water level sensor and mark the sensor wires to help with proper re attachment 5 Replace the new water pump and re install all wires and tubes water pump ME I ki Ion XL J L J 11 2 Replacing the fan motor STEP 1 If the motor is not running first determine the cause Replace only if required STEP 2 Please take off the front and back housings STEP 3 As below picture shows remove four 4 screws to take apart the fan motor from the unit STEP 4 Remove one 1 screw to take apart the fan STEP 5 Remove six 6 screws to take apart the motor STEP 6 Replace the motor and re install all items listed above Step 4 Step 5 18 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 11 3 Replacing the PCB STEP 1 If the PCB stops working begin replacement by taking off the front housing and control panel STEP 2 See picture below Remove six 6 screws to take apart main PCB cover Pull out lead wire of the PCB STEP 3 Replace the main PCB or display PCB STEP
17. r when running replace motor assembly Connection may be loose Check all water connections and repair as 5 Water drips out of needed unit Water pump fault or Check water pump and float switch blockage The unit is not installed The pump basin must be properly properly positioned by keeping unit upright External water pipe or inside Tighten any loose water connections water pipe are loose Poor air circulation Move dehumidifier for free and unobstructed air flow Evaporator coils clogged Clean dust or dirt on the evaporator coils 6 Compressor cycles with dust or dirt on off with overload Fan Motor If fan is not determine the cause protection Replace if required Short circuit or ground in Check electrical circuit Repair as needed electrical circuit Unit pressures not equalized Allow 2 or 3 minutes rest for pressure to equalize before starting compressor Wiring Check the terminals If loose repair or replace Refrigeration system Check the system for a restriction Overload protector O L P Check O L P if externally mounted Replace if open If the compressor temperature is high remove the O L P cool and retest 7 Ineffective Check for gas leakage at Repair gas leak dehumidifying connecting tube 8 No time display PCB Battery low Replace Battery 14 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 9 DISASSEMBLY INSTRUCTIONS WARNING Ensure
18. se the over current protection fuse to blow due to locked rotor on the compressor Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc PERFORMANCE CURVES 110 120V 60Hz Performance curves 220 200 180 CAPACITY 160 Pints Day 140 120 100 80 60 90 F 86 F 80 F 80 F 90 RH 80 RH 80 RH 60 RH AMBIENT TEMPERATURE amp HUMIDITY 1600 1500 1400 POWER avi Watts 1200 1100 1000 900 800 90 F 86 F 80 F 80 F 90 RH 80 RH 80 RH 60 RH AMBIENT TEMPERATURE amp HUMIDITY Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 4 SPECIFICATIONS Ideal CG2 Dehumidifier 110V 120V 60Hz Dehumidifying Capacity 170 pints day 86 F and 80 RH 80L day Dehumidifying Capacity 80 F and 60 RH AHAM Conditions Rating Power Input Current 1300W 11 5A 86 F 80 RH Rating Power Input Current 1045W 9 5A 80 F 60 RH Fan motor 100 pints day 48L day Speed RPM 1350 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 5 PARTS DRAWINGS 5 1 Outside parts drawing r a Part Name Part Spec Air intake metal grill T 1 5 SPCC ee ikr Produet internal component OOOO moor 1 n E L is 1 17 Water pipe l C8 L 8M T s 20 Water pipe come SSS 10 5 2 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc Internal componen
19. smells or smoke comes from product immediately disconnect the power supply Stop operation and close any nearby windows during electrical storms If the unit becomes soaked with water flooded or submerged contact Ideal Air Support before using Disconnect power when cleaning or maintaining the product If not using for an extended period of time disconnect the power supply plug and or turn off the breaker to the unit Do not block the flow of air at the inlet or the outlet It may cause product failure and or unnecessary reduction of useful life To prevent injury be careful when maintaining or moving the unit as metal edges can be sharp Do not insert hands or other object through air outlet while the product is operating There are sharp moving parts inside that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Do not move or tilt the unit while it is operating To avoid water spillage o Do not move the dehumidifier for at least three minutes after turning the power OFF o Do not exceed 45 degree angle in transit Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 2 FUNCTION 2 1 Control panel e Read owners manual before operation e Caution Check machine and filter daily This unit needs a grounded power supply e Do not block air intake or outlet e Do not move or incline the machine when it is running
20. t drawing Water pump support frame Galvanized sheet T 1 0MM evaporator Left support frame Galvanized sheet T 1 5MM 4 1 4 2 4 3 4 4 4 5 4 6 Upper support frame Galvanized sheet T 1 0MM a7 compressor capaet is 4 16 Semi pneumatic Rubber wheel 4 22 Water pipe Z38 L 85mm 11 6 CIRCUIT DIAGRAM a D 5 7 O zi a D A O 2 YELLOW CM COMPRESSOR FMO FAN MOTOR GN GREEN RT THERMISTOR 1 ERROR CODES Error message Display reading Reason Sunlight Supply Inc CIRCUIT DIAGRAM AV ldSid Coil sensor error Flashes every 1 second The coil sensor s terminals are not securely plugged in 1 Check to ensure the coil sensor s terminal is securely plugged in 2 Replace the coil sensor 3 Replace display panel PCB FUSE F6 3A 250V Service Manual Ideal Air CG2 Commercial Grade Dehumidifier POWER SOURCE OVER LOAD PROTECTOR R Humidity sensor error Flashes every 1 second The humidity sensor s terminals are not securely plugged in 1 Check to ensure the humidity sensor s terminal is securely plugged in 2 Replace the humidity sensor 3 Replace display panel PCB 12 Low or no refrigerant Flashes every 1 second 1 The coil sensor has fallen off 2 Refrigerant leak 1 Reinstall coil sensor to the correct position 2 Identify leakage if any
21. the air filter every two months at minimum More frequent cleaning may be needed Use visual inspection weekly to determine if debris build up has clogged the filter Air Filter 10 2 Cleaning the air filter ioni stamens STEP 1 Remove the filter as shown in the diagram below kk ai GEENEN STEP 2 Vacuum any debris from the filter STEP 3 Use lukewarm water and a mild detergent to wash the filt STEP 4 drying STEP 5 Re install the filter into the dehumidifier 10 3 Replacing the battery see images below NOTE Replace the battery every two years or while time fails to show during operation STEP 1 Remove the 4pcs screws in the four corners of the control panel STEP 2 Once the screws are removed carefully remove the control panel to access the PCB STEP 3 On the PCB is a CR2032 battery Remove the battery and replace with new STEP 4 Refit the control panel onto the PCB STEP 5 Refit the four screws CR2032 battery 16 Service Manual Ideal Air CG2 Commercial Grade Dehumidifier Sunlight Supply Inc 10 4 Inspecting wiring connections STEP 1 Refer to instructions for disassembly of the FRONT housing in section 9 1 STEP 2 Remove two 2 screws to take apart main PCB cover Check wire connections inside this access panel 10 5 C