Sun SPARC Enterprise M4000/M5000 Servers Product Notes for
Contents
1. on page 9 5 Ensure that the server can slide in and out of the equipment rack without dislodging the power cables FIGURE 3 and FIGURE 4 shows how the CMA extends and retracts Sun SPARC Enterprise M4000 M5000 Servers Product Notes 7 FIGURE 3 CMA Extended and Retracted on the Sun SPARC Enterprise M4000 Server FIGURE 4 CMA Extended and Retracted on the Sun SPARC Enterprise M5000 Server 6 Slide the server into the equipment rack 7 Tighten the four 4 captive screws at the front of the server to secure the server in the equipment rack 8 Replace the rack stabilizer to its original position 8 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Installing the Extra Brackets Optional The following information belongs in the Sun SPARC Enterprise Equipment Rack Mounting Guide If additional attachment points are required to route the cables you can install the extra brackets that are in the bracket kit The bracket kit contains the following m Two 2 brackets m Four 4 m5 screws a Four 4 cage nuts m 14 velcro strips These brackets can be used with or without the CMA for the Sun SPARC Enterprise M4000 M5000 servers Extend the rack stabilizer Slide the server out of the rack several inches for access to the rear of the Sun Rack Position the cage nuts behind the threaded ears of the Sun Rack and insert the two 2 screws through the brack
2. updated If both banks indicate XCP revision 1060 proceed to the next step XSCF gt flashupdate c update m xcp s 1060 Specify the XCP version to be updated In this example it is 1060 9 Confirm completion of the update XSCF gt showlogs event Confirm no abnormality happens while updating the XSCF 10 Confirm that both the current and reserve banks of the XSCFU display the updated XCP versions XSCF gt version c xcp XSCF 0 Active XCPO Reserve 1060 XCP1 Current 1060 XSCF gt If the Current and Reserve banks on the XSCF do not indicate XCP revision 1060 contact your authorized service representative 26 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 11 Confirm the newly introduced servicetag facility is enabled When a system is upgraded from XCP 104x to XCP 1050 or later the newly introduced servicetag facility is not automatically enabled a Check the servicetag facility status by using the showservicetag CLI XSCF gt showservicetag Disabled b If it is currently disabled you must enable it XSCF gt setservicetag c enable Settings will take effect the next time the XSCF is rebooted c An XSCF reboot is required for the servicetag facility to be enabled XSCF gt rebootxscf The XSCF will be reset Continue y n y Note Service tags are used by Sun Se
3. 4Gb Dual Port Fibre Channel PCI E HBA card SG XPCIE2FC QF4 at the same time that an SAP process is attempting to access storage devices attached to this card The chance of a system hang is increased if the following cards are used for heavy network traffic e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6592302 Unsuccessful DR operation leaves memory It might be possible to recover by adding the partially configured board back to the domain with an addboard d command 6608404 Hot plug of the X4447A Z PCI e Quad port To avoid the defect do not install this card in Gigabit Ethernet Adapter UTP card in slot 1 slot 1 might cause other network devices to fail 6619344 The Sun Crypto Accelerator SCA 6000 card To avoid the defect do not hot plug this card might not work if hot plug configured into in slot 1 slot 1 24 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Preparing to Upgrade to XCP 1050 or Later The following step must be completed prior to upgrading Delete any accounts named admin Use the showuser lu command to list all XSCF accounts Any accounts named admin must be deleted prior to upgrading to XCP 1050 This account name is reserved in XCP 1050 and higher Use the deleteuser command to delete the account Note For more information on admin accounts see TABLE 9 Software Doc
4. jar c To install the patch follow the special installation instructions in the file var sadm spool 118833 xx README 118833 xx 6 After installing patch 118833 xx restart the system m To restart the system use either the init command or the shutdown command init 6 shutdown i6 Note The reboot command does not complete installations of patches that require a restart 7 Display a list of patches to be installed by typing the command smpatch analyse 8 Download and install the patches by typing the command smpatch update 9 If any of the patches requires a system restart see Step 6 The patch installation is now complete Preface xi Additional Information For additional information read the release notes which come with your Solaris documentation as well as the latest Solaris 10 Sun Hardware Platform Guide Also check the documentation web page for any additional supplements to this book The most up to date information is posted at http www sun com documentation Accessing Documentation Instructions for installing administering and using your servers are provided in the Sun SPARC Enterprise M4000 M5000 servers documentation set The entire documentation set is available for download from the following web site http www sun com documentation Note Information in these product notes supersedes the information in the S
5. of other patch requirements 123839 xx minimum revision 07 120068 xx minimum revision 03 125424 xx minimum revision 01 OS OF FF Q 118918 xx minimum revision 24 2 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 7 120222 xx minimum revision 21 8 125127 xx minimum revision 01 Reboot your domain before proceeding 9 125670 xx minimum revision 02 10 125166 xx minimum revision 05 Known Issues This section describes known hardware and software issues in this release General Functionality Issues and Limitations Caution For dynamic reconfiguration DR and hot plug issues see TABLE 8 Solaris Issues and Workarounds on page 18 m For 1027A Z X1027A Z PCIe Dual 10 Gigabit Ethernet Fiber XFP cards these limits apply a Do not use more than two cards per domain Do not use these cards in an External I O Expansion Unit m For 4447A Z X4447A Z PCIe Quad port Gigabit Ethernet Adapter UTP cards these maximum limits apply a No more than two cards in an External I O Expansion Unit a No more than four cards in a Sun SPARC Enterprise M4000 server No more than eight cards in a Sun SPARC Enterprise M5000 server To complete updating the OpenBoot PROM firmware in the target domain be sure to power off on the domain m When the Solaris OS is in single user mode do not switch from the domain console to the XSCF Shell as the Solaris O
6. with Two 30A 3 phase MPS Server M5000 PSU_3 M5000 PSU_2 M5000 PSU_1 M5000 PSU_O M5000_2 MPS_1 B2 MPS_1 A2 MPS_0 B2 MPS_0 A2 M5000_1 MPS_1 B1 MPS_1 A1 MPS_0 B1 MPS_0 A1 M5000_0 MPS_1 B0 MPS_1 A0 MPS_0 BO MPS_0 A0 Sun SPARC Enterprise M4000 M5000 Servers Product Notes 13 a DES hi PSU_3 PSU_2 PSU_1 PSU 0 t l a Server 2 Server 1 H pi Server 0 Il 9 fe MPS_1 MPS_0O MPS _0 B MPS_0O A FIGURE7 Sun Rack 1000 With Three Sun SPARC Enterprise M5000 Servers and Two MPS 14 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Electrical Specifications The following changes belong in the Sun SPARC Enterprise M4000 M5000 Servers Site Planning Guide and the Sun SPARC Enterprise M4000 M5000 Servers Service Manual FIGURE 8 Midrange Servers Electrical Specifications SPARC Enterprise M4000 SPARC Enterprise M5000 Volt Ampere 2 058 VA 3 815 VA 24 0A at 100 127 VAC 12A cord 12 0A at 200 240 VAC 12A cord Maximum current 6 879 BTUs hr 7 258 kJ hr Heat dissipation 48A at 100 127 VAC 12A cord 24A at 200 240 VAC 12A cord 12 754 BTUs hr 13 457 kJ hr Input voltage 100 127 VAC 100 127 VAC 200 240 VAC 200 240 VAC Plug type IEC 60320 C20 IEC 60320 C20 IEC 60309 16A 250V All other IEC 60309 16A 250V All other locations except Japan Korea and locations except Japan Korea Taiwan Taiwan NEMA L5 15 125V 15A Americas and NEMA L5 15 125V 15A Am
7. 25670 04 6572827 On Sun SPARC Enterprise M4000 M5000 There is no workaround platforms one of the columns in the IO Devices section of the output from prtdiag v is Type This reports PCIe PCIx PCI or UNKN for each device The algorithm used to compute this value is incorrect It reports PCI for PCI X leaf devices and UNKN for legacy PCI devices 6575970 DR and XSCF failover are not compatible Do not start an XSCF failover while a DR operation is running Wait for a DR operation to finish before starting the failover If you start the failover first wait for the failover to finish before starting the DR operation 6583035 After using the addfru or replacefru When performing the addfru and command to hotplug a CMU further DR operations might fail with a misleading message regarding the board being unavailable for DR replacefru commands it is mandatory to run diagnostic tests If you forget to run the diagnostic tests during addfru replacefru then either run testsb to test the CMU or remove the CMU IOU with the deletefru command and then use the addfru command with the diagnostic tests Sun SPARC Enterprise M4000 M5000 Servers Product Notes 23 TABLE8 Solaris Issues and Workarounds Continued CR ID Description Workaround 6589833 The DR addboard command might cause a There is no workaround Check for the system hang if you are adding a Sun availability of a patch for this defect StorageTek Enterprise Class
8. 6488846 During boot the domain console might Check for the availability of the latest controller display a checksum error for the card firmware SG X PCI2SCSIU320 Z SCSI controller I O card 6498780 On the Sun SPARC Enterprise The PCI or PCI X plug in adapter card might not be M4000 M5000 servers the OpenBoot PROM OBP might not detect the on board disk HDD boot device Performing a boot disk results in a console message Can t locate boot device seated correctly Reseat the card in slot 0 of the IOU U320 PCIe SCSI Card U320 PCIe SCSI card part numbers 375 3357 01 02 is not supported in PCI cassettes for Sun SPARC Enterprise M4000 M5000 servers Customers must use 375 3357 03 or later 4 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 DIMM Replacement DIMMs are cold FRU replacement components The entire server must be powered off and the power cords disconnected to replace the DIMMs You can mount up to 4 memory boards on the Sun SPARC Enterprise M4000 server and up to 8 memory boards on the Sun SPARC Enterprise M5000 server The DIMMs on the memory board are grouped into group A and group B DIMM mounting rules Four 4 DIMMs per group can be mounted m Capacity of the DIMMs in group A must be equal to or larger than the capacity of the DIMMs in group B m The capacity of the DIMMs in group B must be equal to or less than the capacity of the DIMMs in group A D
9. 817 5504 6mkv4nh63 a view If you do not upgrade the wanboot executable the Sun SPARC Enterprise M4000 M5000 server will panic with messages similar to the following krtld load_exec fail to expand cpu S CPU krtld error during initial load link phase panic boot exitto64 returned from client program See http docs sun com app docs doc 817 5504 6mkv4nh5i a view for more information on WAN boot Abbreviated Man Page for getflashimage In XCP 105x the command get flashimage is available which can be used to download firmware images in place of the XSCF Web Sun SPARC Enterprise M4000 M5000 Servers Product Notes 29 Software Documentation Updates This section contains late breaking information on the software documentation that became known after the documentation set was published TABLE9 Software Documentation Updates Document Page Number All Sun SPARC Enterprise M4000 M5000 M8000 M9000 servers documentation Sun SPARC Enterprise Page 9 5 M4000 M5000 M8000 M9000 Servers XSCF User s Guide Sun SPARC Enterprise Page 2 2 M4000 M5000 M8000 M9000 Servers XSCF User s Guide Change All DVD references are now referred to as CD RW DVD RW The list of web browsers supported by the XSCF Web include e Microsoft Internet Explorer 6 0 or later Firefox 2 0 or later e Mozilla 1 7 or later e Netscape Navigator 7 1 or later Setup Summary by the XSCF Shell section Add the following Note Note In addi
10. CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON Contents Preface vii Technical Support vii Software Resources vii Obtaining the Latest Solaris Patches viii Using the Update Manager GUI to Obtain Patches ix Using the smpatch CLI to Obtain Patches x Additional Information xii Accessing Documentation xii Sun Welcomes Your Comments xii Sun SPARC Enterprise M4000 M5000 Servers Product Notes 1 Supported Firmware and Software Versions 1 Solaris Patch Information 2 Installing the Solaris Patches 2 Known Issues 3 General Functionality Issues and Limitations 3 Hardware Installation and Service Issues 4 Specific Issues and Workarounds 4 U320 PCIe SCSI Card 4 DIMM Replacement 5 Installing the PCI Cassette 5 Attaching End Caps to the Rails 6 Installing the Extra Brackets Optional 9 Power Wiring Configurations 11 Electrical Specifications 15 Hardware Documentation Updates 15 Software and Firmware Issues 17 XCP Issues and Workarounds 17 Solaris Issues and Workarounds 18 Preparing to Upgrade to XCP 1050 or Later 25 Upgrading From XCP 104x to XCP 1050 or Later 25 Identifying Permanent Memory in a Target Board 28 Booting From a WAN Boot Server 29 Abbreviated Man Page for getflashimage 29 Software Docume
11. IATES MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND EXPRESS OR IMPLIED REGARDING SUCH PRODUCT OR TECHNOLOGY OR THIS DOCUMENT WHICH ARE ALL PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Unless otherwise expressly set forth in such agreement to the extent allowed by applicable law in no event shall Fujitsu Limited Sun Microsystems Inc or any of their affiliates have any liability to any third party under any legal theory for any loss of revenues or profits loss of use or data or business interruptions or for any indirect special incidental or consequential damages even if advised of the possibility of such damages DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Sd mon Ca Adobe PostScript Copyright 2007 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A et FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japon Tous droits r serv s Entr e et revue tecni
12. IMMs in group B are optional m For both groups DIMMs must be of the same capacity and rank within a group DIMMs of different capacity cannot be mixed in a group Installing the PCI Cassette The following changes belong in the Sun SPARC Enterprise M4000 M5000 Servers Service Manual Caution Do not force the PCI cassette into a slot Doing so can cause damage to the cassette and server Align the PCI cassette on the gray plastic guide and install it into the slot Lock the lever into place to seat the cassette Note As the lever is moved pressure builds up then just prior to locking into place the pressure suddenly releases If the lever locks in place without the pressure release the card might not be seated correctly If this happens remove and reinstall the card Note When you insert the PCI cassette using hot swap the cassette is automatically powered on and configured Check that the power LED on the cassette is lit to be certain the cassette is correctly seated Connect all cables to the PCI cassette and reconnect the cable management arm if necessary Sun SPARC Enterprise M4000 M5000 Servers Product Notes 5 Attaching End Caps to the Rails The following information belongs in the Sun SPARC Enterprise Equipment Rack Mounting Guide After securing the cable management arm CMA to the Sun SPARC Enterprise M4000 M5000 server attach the provided end caps to the rails 1 Secure t
13. Microsystems Inc and their applicable licensors if any The furnishing of this document to you does not give you any rights or licenses express or implied with respect to the product or technology to which it pertains and this document does not contain or represent any commitment of any kind on the part of Fujitsu Limited or Sun Microsystems Inc or any affiliate of either of them This document and the product and technology described in this document may incorporate third party intellectual property copyrighted by and or licensed from suppliers to Fujitsu Limited and or Sun Microsystems Inc including software and font technology Per the terms of the GPL or LGPL a copy of the source code governed by the GPL or LGPL as applicable is available upon request by the End User Please contact Fujitsu Limited or Sun Microsystems Inc This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot and Sun Fire are trademarks or registered trademarks of Sun Microsystems Inc in the U S and other countries Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used un
14. S Ry SUN microsystems Sun SPARC Enterprise M4000 M5000 Servers Product Notes For XCP Version 1060 Sun Microsystems Inc www sun com Part No 820 3612 10 November 2007 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2007 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A and FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japan All rights reserved Sun Microsystems Inc and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document and such products technology and this document are protected by copyright laws patents and other intellectual property laws and international treaties The intellectual property rights of Sun Microsystems Inc and Fujitsu Limited in such products technology and this document include without limitation one or more of the United States patents listed at http www sun com patents and one or more additional patents or patent applications in the United States or other countries This document and the product and technology to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of such product or technology or of this document may be reproduced in any form by any means without prior written authorization of Fujitsu Limited and Sun
15. S might switch to multi user mode m The XSCF web browser interface also known as the browser interface BUI does not support the External I O Expansion Unit Manager feature m The XSCF web browser interface also known as the browser user interface BUI supports new features concerning the COD configuration a You cannot use the following user account names as they are reserved by the XSCF firmware for system use root bin daemon adm operator nobody sshd rpc rpcuser ldap apache ntp admin and default Sun SPARC Enterprise M4000 M5000 Servers Product Notes 3 Do not use the Service Processor SP as the Network Time Protocol NTP server Using an independent NTP server provides optimal reliability in maintaining consistent time on the SP and the domains For more information about NTP see the Sun Blueprint document Using NTP to Control and Synchronize System Clocks http www sun com blueprints 0701 NTP pdf Hardware Installation and Service Issues This section describes hardware specific issues and workarounds Specific Issues and Workarounds TABLE 1 lists known issues for which a defect change request ID has been assigned The table also lists possible workarounds TABLE1 Hardware Issues and Workarounds CR ID Description Workaround 6433420 The domain console might display a Issue a reset all command from the OBP OK Mailbox timeout or IOCB interrupt timeout prompt and reboot error during boot
16. an be downloaded from http sunsolve sun com if needed These patches are not required for servers running Solaris 10 8 07 OS The Sun Connection Update Manager can be used to reinstall the patches if necessary or to update the system with the latest set of mandatory patches For more Information about the Sun Connection Update Manager refer to the Sun Update Connection System 1 0 8 Administration Guide http docs sun com app docs doc 819 4687 Or visit http wikis sun com display SunConnection Update Manager There are two options available to register your system and use the Sun Connection Update Manager to obtain the latest Solaris OS patches Installation information and README files are included in the patch download m Using the Update Manager GUI to Obtain Patches on page ix m Using the smpatch CLI to Obtain Patches on page x Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Using the Update Manager GUI to Obtain Patches Launch the Update Manager a From JDS Launch menu Launch gt Applications gt System Tools gt Update Manager m From a terminal window with the CLI type in usr bin updatemanager a If you have already registered proceed to Step 2 b If you have not yet registered Update Manager will take you through the registration process Follow the on screen instructions In the Available tab in the Update Manager open the Update Collection d
17. cal fournies par Fujitsu Limited sur des parties de ce mat riel Sun Microsystems Inc et Fujitsu Limited d tiennent et contrdlent toutes deux des droits de propri t intellectuelle relatifs aux produits et technologies d crits dans ce document De m me ces produits technologies et ce document sont prot g s par des lois sur le copyright des brevets d autres lois sur la propri t intellectuelle et des trait s internationaux Les droits de propri t intellectuelle de Sun Microsystems Inc et Fujitsu Limited concernant ces produits ces technologies et ce document comprennent sans que cette liste soit exhaustive un ou plusieurs des brevets d pos s aux Etats Unis et indiqu s l adresse http www sun com patents de m me qu un ou plusieurs brevets ou applications brevet es suppl mentaires aux Etats Unis et dans d autres pays Ce document le produit et les technologies aff rents sont exclusivement distribu s avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit de ces technologies ou de ce document ne peut tre reproduite sous quelque forme que ce soit par quelque moyen que ce soit sans l autorisation crite pr alable de Fujitsu Limited et de Sun Microsystems Inc et de leurs ventuels bailleurs de licence Ce document bien qu il vous ait t fourni ne vous conf re aucun droit et aucune licence expresses ou tacites concernant le produi
18. der license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Sun Microsystems Inc and Fujitsu Limited and the applicable provisions of the FAR and its supplements Disclaimer The only warranties granted by Fujitsu Limited Sun Microsystems Inc or any affiliate of either of them in connection with this document or any product or technology described herein are those expressly set forth in the license agreement pursuant to which the product or technology is provided EXCEPT AS EXPRESSLY SET FORTH IN SUCH AGREEMENT FUJITSU LIMITED SUN MICROSYSTEMS INC AND THEIR AFFIL
19. ds from bottom to top and right to left TABLE2 Wiring Connections for Six Sun SPARC Enterprise M4000 Servers with One 60A 3 phase MPS Server M4000_5 M4000_4 M4000_3 M4000_2 M4000_1 M4000_0 M4000 PSU_1 MPS_0 A5 MPS_0 A4 MPS_0 A3 MPS_0 A2 MPS_0 A1 MPS_0 A0 M4000 PSU_O MPS_0 B5 MPS_0 B4 MPS_0 B3 MPS_0 B2 MPS_0 B1 MPS_0 BO TABLE3 Wiring Connections for Six Sun SPARC Enterprise M4000 Servers with Two 30A 3 phase MPS Server M4000 PSU_1 M4000 PSU_0 M4000_5 MPS_1 B5 MPS_1 A5 M4000_4 MPS_0 B4 MPS_0 A4 M4000_3 MPS_1 B3 MPS_1 A3 M4000_2 MPS_0 B2 MPS_0 A2 M4000_1 MPS_1 B1 MPS_1 A1 M4000_0 MPS_0 BO MPS_0 A0 Sun SPARC Enterprise M4000 M5000 Servers Product Notes 11 Server 5 Server 4 Server 3 Server 2 Server 1 Server 0 MPS_0 MPS_0 B MPS_O A FIGURE6 Sun Rack 1000 With Six Sun SPARC Enterprise M4000 Servers and One MPS 12 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Note The numbering in a Sun Rack reads from bottom to top and right to left TABLE4 Wiring Connections for Three Sun SPARC Enterprise M5000 Servers with One 60A 3 phase MPS Server M5000 PSU_3 M5000 PSU_2 M5000 PSU_1 M5000 PSU_O M5000_2 MPS_0 B5 MPS_0 A5 MPS_0 B4 MPS_0 A4 M5000_1 MPS_0 B3 MPS_0 A3 MPS_0 B2 MPS_0 A2 M5000_0 MPS_0 B1 MPS_0 A1 MPS_0 BO MPS_0 A0 TABLE5 Wiring Connections for Three Sun SPARC Enterprise M5000 Servers
20. ed using PCI hotplug the PCI card information is displayed correctly Sun SPARC Enterprise M4000 M5000 Servers Product Notes 19 TABLE8 Solaris Issues and Workarounds Continued CR ID Description Workaround 6530178 DR addboard command can hang Once the There is no workaround Check for the problem is observed further DR operations availability of a patch for this defect are blocked Recovery requires reboot of the domain This bug has been fixed in Solaris 10 8 07 6531036 The error message network There is no workaround initialization failed can appear repeatedly after boot net installation 6533686 An error condition can occur when a physical If the board is shared between domains do not board is shared between 2 domains use DR at the same time on this shared board 6534471 Systems might panic trap during normal Make sure you have the correct etc system operation parameter and reboot the system set heaplp_use_stlb 0 This bug has been fixed in Solaris 10 8 07 6539084 There is a low probability of a domain panic There is no workaround Check for the during reboot when the Sun Quad GbE UTP availability of a patch for this defect x8 PCIe X4447A Z card is present in a domain Check http sunsolve sun com for patch 125670 01 This defect only applies to Solaris 10 11 06 6539909 Do not use the following I O cards for When running Solaris 10 11 06 use an network access when you are using the boot alternate type of networ
21. ericas Taiwan and Taiwan NEMA L6 20 250V 20A Americas NEMA L6 20 250V 20A Americas Japan Korea and Taiwan Japan Korea and Taiwan Hardware Documentation Updates This section contains late breaking hardware information that became known after the documentation set was published TABLE 6 lists known documentation updates TABLE6 Hardware Documentation Updates Title Page Number Update All SPARC Enterprise All DVD references are now referred to as CD RW DVD RW M4000 M5000 servers documentation Sun SPARC Enterprise M4000 M5000 Servers Product Notes 15 TABLE6 Hardware Documentation Updates Title Page Number Update Sun SPARC Enterprise M4000 M5000 Servers Site Planning Guide Sun SPARC Enterprise M4000 M5000 Servers Service Manual Sun SPARC Enterprise M4000 M5000 Servers Installation Manual Sun SPARC Enterprise M8000 M9000 Servers Overview Guide 2 4 11 7 C 7 Page 1 8 Updated glossary terms External I O Expansion Unit A rackmountable device to add on PCI slots It is connected to the system s I O unit through the PCIe connection and contains one or two I O boats I O boat An I O unit in the External I O Expansion Unit The I O boat connects to a PCI Express PCIe slot through a PCle switch or a PCI X bridge on the I O boat and offers either six PCI X slots or six PCle slots TABLE 1 3 Midrange Servers Physical Specifications Correct numerical value of Depth i
22. et and rack ear FIGURE 5 Brackets should be positioned near the top level of the server or slightly below it Note Brackets can be installed one per side one only right or left side or two on one side as desired for convenience in cable management Sun SPARC Enterprise M4000 M5000 Servers Product Notes 9 4 Twist the cage nuts onto the screws from behind the rack ears The flat edges of the cage nuts should be aligned with the rack post to prevent the server from scraping against it FIGURES Installing the Extra Brackets in a Sun Rack 1000 5 Insert velcro strips in the desired slots of the bracket to hold back cables Built in cutouts along the sides of the Sun Rack can also be used to insert velcro strips to hold back cables as desired 6 Slide the server into the equipment rack 7 Replace the rack stabilizer to its original position 10 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Power Wiring Configurations The following information belongs in the Sun SPARC Enterprise Equipment Rack Mounting Guide To ensure redundant power sourcing use the provided wiring configurations for the Sun SPARC Enterprise M4000 M5000 servers in a Sun Rack 1000 38 42 The Sun Rack 1000 38 42 can fit up to two modular power supplies MPS Each MPS is two rack units tall The MPS must be installed into the bottom of the rack Note The numbering in a Sun Rack rea
23. gularly the Latest communication field in showarchiving output 6577801 An incorrect domain state is reported After There is no workaround This is a side effect of the command sendbreak is issued to a the sendbreak operation domain showdomainstatus shows the state as Running when the domain is at the ok prompt 6588650 On occasion the system is unable to DR after There is no workaround Check for the an XSCF failure and reboot availability of a patch for this defect 6589870 A user account name which consists of 32 Use up to 31 characters to set the XSCF user characters will display Permission denied account name 6590920 The CLI showldap c which displays current Use the same user account for all LDAP LDAP certificates will show proper data only display or configuration operations for both when used with the same user account that CLI and XSCF Web had originally provided certificate information using setldap c Any other user account will generate Permission denied error Similarly the XSCF Web s LDAP Configuration pop up screen will display no data when a different user account is used 6598444 The XSCF firmware monitors itself and if it There is no workaround Allow the XSCF Unit detects any inconsistencies it forces an XSCF to finish rebooting It returns to normal reboot operation within approximately five minutes 6626183 When Internet Explorer 7 browser is used the Use other browsers Lice
24. he CMA to the server Refer to the Sun SPARC Enterprise Equipment Rack Mounting Guide for information on installing the CMA to the server 2 Attach the end caps onto the slide rails m For the Sun SPARC Enterprise M4000 server an end cap is attached to both the right and left rear rails FIGURE 1 m For the Sun SPARC Enterprise M5000 server both end caps are attached to the rails on the same side to which the CMA is not attached FIGURE 2 Note If the CMA is not used attach all end caps to the rails of the server The SPARC Enterprise M4000 server uses two end caps The SPARC Enterprise M5000 server uses four end caps FIGURE1 End Caps on the Sun SPARC Enterprise M4000 Slide Rails 6 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 FIGURE 2 End Caps on the Left Rear of the Sun SPARC Enterprise M5000 Slide Rails 3 Connect the power cables to the rear of the server and secure them with the cable retention clamps Caution Do not connect the power cables to a power source at this time 4 Run the power cables beneath the CMA and secure them in place with tie wraps The power cables and infiniband cables should hang loosely in a service loop behind the server or the CMA might not be able to fully retract Note If additional attachment points are required to route the cables install the optional bracket kit See Installing the Extra Brackets Optional
25. he console with the following cards e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter For Solaris 10 8 07 check http sunsolve sun com for patch 127741 01 Sun SPARC Enterprise M4000 M5000 Servers Product Notes 21 TABLE 8 CR ID Solaris Issues and Workarounds Continued Description Workaround 6563785 6564332 6564934 6568417 Hot plug operation with the following cards might fail during back to back disconnect and connect operations e SG XPCIE2SCSIU320Z Sun StorageTek PCI E Dual Port Ultra320 SCSI HBA e SGXPCI2SCSILM320 Z Sun StorageTek PCI Dual Port Ultra320 SCSI HBA Hot plug operations on Sun Crypto Accelerator SCA 6000 cards can cause Sun SPARC Enterprise M4000 M5000 servers to panic or hang Performing a DR deleteboard operation on a board which includes Permanent Memory when using the following network cards results in broken connections X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter After a successful CPU DR deleteboard operation the system panics when the following network interfaces are in use X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter After disconnecting a card wait for a few seconds before re connecting Check
26. he problem on the next boot 6520990 When a domain reboots SCF might not be Increase the DR timeout period by setting the able to service other domains that share the following statement in etc system and reboot same physical board DR operation can your system exceed the default timeout period and panic AROCEUT set drmach fmem_timeout 30 This workaround is not needed if no physical board is shared among multiple domains This bug has been fixed in Solaris 10 8 07 6522017 DR and ZFS might not be used in the same Set the maximum size of the ZFS ARC lower domain For detailed assistance contact Sun Service 6522433 The incorrect motherboard may be identified None at this time Check for the availability of by fmdump for cpu faults after reboot a patch for this defect 6522017 Domains using the ZFS file system cannot use Set the maximum size of the ZFS ARC lower DR For detailed assistance contact Sun Service 6527781 The cfgadm command fails while moving the There is no workaround To reconfigure DVD DAT drive between two domains DVD Tape drive execute reboot r from the domain exhibiting the problem This bug has been fixed in Solaris 10 8 07 6527811 The showhardconf 8 command on the There is no workaround When each PCI card XSCF cannot display PCI card information that is installed in the External I O Expansion Unit if the External I O Expansion Unit is configured using PCI hot plug in the External I O Expansion Unit is configur
27. http sunsolve sun com for patch 127750 01 Hot plug does not work for the SCA6000 when running version 1 0 of the SCA6000 driver and should not be attempted Version 1 1 of the SCA6000 driver and firmware supports hot plug operations after the required bootstrap firmware upgrade has been performed Note See CR ID 6619344 for issues with hot plug of Sun Crypto Accelerator SCA 6000 cards in slot 1 Re configure the affected network interfaces after the completion of the DR operation For basic network configuration procedures refer to the ifconfig man page for more information Check http sunsolve sun com for patch 127741 01 Add the following line to etc system and reboot the system set ip ip_soft_rings_cnt 0 Check http sunsolve sun com for patch 127111 02 22 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 TABLE8 Solaris Issues and Workarounds Continued CR ID Description Workaround 6571370 Use of the following cards have been Add the following line in etc system and observed to cause data corruption in stress reboot the system test under laboratory conditions set nxge nxge_rx_threshold_hi 0 e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP For Solaris 10 8 07 check X1027A Z1 PCI e Dual 10 Gigabit Ethernet http sunsolve sun com for patch Fiber XFP Low profile Adapter 127741 01 For Solaris 10 11 06 check http sunsolve sun com for patch 1
28. ick the Install button Update Manager will download and install the patches Note If any restart required patches were installed UM will offer to restart the system Alternatively shutdown or init as used in Step 6 can be used For restart required patches the restart is required before the patches are effectively installed 11 If any of the patches requires a system restart see Step 6 The patch installation is now complete Using the smpatch CLI to Obtain Patches 1 Copy the file usr lib breg data RegistrationProfile properties to your tmp directory 2 Edit the file tmp RegistrationProfile properties to add your user name password network proxy if necessary and port if required Note The user name and password is a Sun Online Account To create an account go to http sunsolve sun com 3 Register your system by typing the command sconadm register a r tmp RegistrationProfile properties 4 Obtain the correct patches for your system by typing the command smpatch set patchpro patchset sem4k5k8k9k x Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 5 Install patch 118833 xx as follows This patch can be downloaded through the Sun Connection Update Manager a Download the patch to your var sadm spool directory by typing smpatch update i 118833 xx b To unzip the patch type cd var sadm spool unzip 118833 xx
29. it ou toute technologie d crit e dans les pr sentes correspondent aux garanties express ment stipul es dans le contrat de licence r gissant le produit ou la technologie fourni e SAUF MENTION CONTRAIRE EXPRESSEMENT STIPULEE DANS CE CONTRAT FUJITSU LIMITED SUN MICROSYSTEMS INC ET LES SOCIETES AFFILIEES REJETTENT TOUTE REPRESENTATION OU TOUTE GARANTIE QUELLE QU EN SOIT LA NATURE EXPRESSE OU IMPLICITE CONCERNANT CE PRODUIT CETTE TECHNOLOGIE OU CE DOCUMENT LESQUELS SONT FOURNIS EN L TAT EN OUTRE TOUTES LES CONDITIONS REPRESENTATIONS ET GARANTIES EXPRESSES OU TACITES Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALIT MARCHANDE L APTITUDE UNE UTILISATION PARTICULI RE OU L ABSENCE DE CONTREFA ON SONT EXCLUES DANS LA MESURE AUTORIS E PAR LA LOI APPLICABLE Sauf mention contraire express ment stipul e dans ce contrat dans la mesure autoris e par la loi applicable en aucun cas Fujitsu Limited Sun Microsystems Inc ou l une de leurs filiales ne sauraient tre tenues responsables envers une quelconque partie tierce sous quelque th orie juridique que ce soit de tout manque gagner ou de perte de profit de probl mes d utilisation ou de perte de donn es ou d interruptions d activit s ou de tout dommage indirect sp cial secondaire ou cons cutif m me si ces entit s ont t pr alablement inform es d une telle ventualit LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES
30. k card or onboard net install command to install the Solaris network device to install the Solaris OS via the OS network e X4447A Z X4447A Z PCIe Quad port Gigabit Ethernet Adapter UTP This defect does not exist in Solaris 10 8 07 e X1027A Z X1027A Z PCIe Dual 10 Gigabit Ethernet Fiber XFP 6545143 When kcage daemon is expanding the kcage There is no workaround Check for the area if the user stack exists in the expanded availability of a patch for this defect area its area is demapped and might cause a ptl_1 panic during the flushw handler execution 6545685 If the system has detected Correctible Increase the memory patrol timeout values Memory Errors CE at power on self test POST the domains might incorrectly degrade 4 or 8 DIMMs used via the following setting in etc system and reboot the system set mc opl mc_max_rewrite_loop 20000 20 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 TABLE8 Solaris Issues and Workarounds Continued CR ID Description Workaround 6546188 The system panics when running hot plug For Solaris 10 8 07 check cfgadn and DR operations addboard and http sunsolve sun com for patch deleteboard on 127741 01 e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP For Solaris 10 11 06 check e X1027A Z1 PCI e Dual 10 Gigabit Ethernet http sunsolve sun com for patch Fiber XFP Low profile Adapter 125670 04 Note See CR ID 6608404 rega
31. nse key deletion cannot be executed on the BUI COD page Microsoft Internet Explorer 6 0 Firefox 2 0 or later e Mozilla 1 7 or later Netscape Navigator 7 1 or later Sun SPARC Enterprise M4000 M5000 Servers Product Notes 17 Solaris Issues and Workarounds TABLE 8 lists Solaris issues and possible workarounds TABLE8 Solaris Issues and Workarounds CR ID Description Workaround 6348554 Using the cfgadm c disconnect Do not perform cfgadm c disconnect command on the following cards might hang operation on the affected cards the command e SG XPCIE2FC QF4 Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Check http sunsolve sun com for Channel PCI E HBA patch 126670 01 e SG XPCIE1FC QF4 Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCI E HBA e SG XPCI2FC QF4 Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCI X HBA e SG XPCI1FC QF4 Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCI X HBA 6459540 The DAT72 internal tape drive might time out Add the following definition to during tape operations kernel drv st conf The device might also be identified by the system as a QIC drive tape config list SEAGATE DAT DAT72 000 SEAGATE DAT DAT72 000 SEAGATE _ DAT DAT72 000 SEAGATE DAT DAT 72 000 1 0x34 0 0x9639 4 0x00 0x8c 0x8c 0x8c 3 There are four spaces between SEAGATE DAT and DAT72 000 6472153 If you create a Solaris Flash archive on a non J
32. ntation Updates 30 vi Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Preface These Product Notes contain important and late breaking information about the Sun SPARC Enterprise M4000 M5000 servers hardware software and documentation that became known after the documentation set was published Technical Support If you have technical questions or issues that are not addressed in the Sun SPARC Enterprise M4000 M5000 servers documentation contact your local Sun Service representative For customers in the U S or Canada call 1 800 USA 4SUN 1 800 872 4786 For customers in the rest of the world find the World Wide Solution Center nearest you by visiting the following web site http www sun com service contacting solution htm1 Software Resources The Solaris Operating System and Sun Java Enterprise System software are preinstalled on your Sun SPARC Enterprise M4000 M5000 servers vii viii Obtaining the Latest Solaris Patches The mandatory Solaris patches for the SPARC Enterprise M8000 M9000 servers should be preinstalled on your system See Solaris Patch Information on page 2 for the list of patches required on your version of the Solaris OS Caution For Sun SPARC Enterprise M4000 M5000 servers running Solaris 10 11 06 OS patches 123003 03 and 124171 06 must be installed on your system prior to using Sun Connection Update Manager These patches c
33. owdevices d domain_id The following example shows a display of the showdevices d command where 0 is the domain_id XSCF gt showdevices d 0 Memory board perm base domain target deleted remaining DID XSB mem MB mem MB address mem MB XSB mem MB mem MB 00 00 0 8192 O 0x0000000000000000 24576 00 00 2 8192 1674 0x000003c000000000 24576 00 00 3 8192 O 0x0000034000000000 24576 28 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 The entry for column 4 perm mem MB indicates the presence of permanent memory if the value is non zero The example shows permanent memory on 00 2 with 1674 MB If the board includes permanent memory and executes the deleteboard command or moveboard command the following notification is displayed System may be temporarily suspended proceed y n Booting From a WAN Boot Server To support booting the Sun SPARC Enterprise M4000 M5000 server from a WAN boot server Install the Solaris 10 11 06 OS on the WAN boot server Copy the wanboot executable from that release to the appropriate location on the install server If you need further instructions refer to the Solaris 10 Installation Guide Network Based Installations or refer to http docs sun com app docs doc 817 5504 6mkv4nh65 a view Create a WAN boot miniroot from the Solaris 10 11 06 OS If you need further instructions refer to http docs sun com app docs doc
34. rchived log files The SP Security SUNWspec Package gives administrators and service providers a means to view those files To display the XSCF audit log files archived to your server use the viewauditapp 8 and mergeaudit 8 off platform audit file viewers Sun SPARC Enterprise M4000 M5000 Servers Product Notes 31 TABLE9 Software Documentation Updates Document Page Number Continued Change Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF Reference Manual Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF Reference Manual setpowerupde lay 8 manpage setupplatfor m 8 manpage The following description is added in EXTENDED DESCRIPTION When the power is turned on from the operator panel the wait time and warm up time that you set are ignored If you have set these times and wish for the system to use them at startup perform the poweron 8 command The p user option requires useradm privileges The p network option requires either platadm or fieldeng privileges The p altitude option requires platadm privileges The p timezone option requires platadm privileges 32 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007
35. rding issues with hot plug of these cards in slot 1 6551356 The system panics when running hot plug DO NOT use cfgadm c unconfigure to cfgadm to configure a previously disconnect the I O card Perform cfgadm c unconfigured card The message WARNING disconnect to completely remove the card PCI Expansion ROM is not accessible will be After waiting at least 10 seconds the card seen on the console shortly before the system might be configured back into the domain panic The following cards are affected by using the cfgadm c configure command this defect e X4447A Z PCI e Quad port Gigabit For Solaris 10 8 07 check Ethernet Adapter UTP http sunsolve sun com for patch X1027A Z1 PCI e Dual 10 Gigabit Ethernet 127741 01 Fiber XFP Low profile Adapter 6556742 The system panics when DiskSuite cannot Panic can be avoided when a duplicated copy read the metadb during DR This bug affects of the metadb is accessible via another Host the following cards Bus Adaptor Or you can apply patch e SG XPCIE2FC QF4 4Gb PCI e Dual Port 125166 06 Fibre Channel HBA e SG XPCIEIFC QF4 4Gb PCI e Single Port Fibre Channel HBA Check http sunsolve sun com for SG XPCI2FC OF4 4Gb PCI X Dual Port patch 125166 06 Fibre Channel HBA e SG XPCTIFC QF4 4Gb PCI X Single Port Fibre Channel HBA 6559504 Messages of the form nxge NOTICE These messages can be safely ignored nxge_ipp_eccue valid check rd_ptr nnn wr_ptr nnn will be observed on t
36. ris 10 8 07 For systems running Solaris 10 11 06 you can upgrade to Solaris 10 8 07 or apply patch 120011 08 This CR is listed in the section Solaris Issues and Workarounds on page 18 Note All Sun SPARC Enterprise M4000 M5000 servers must be upgraded to XCP 1050 or later in order to support adding future Capacity On Demand COD Right To Use RTU licenses Contact your local Service Representative for assistance If you plan to boot your Sun SPARC Enterprise M4000 M5000 server from a Solaris WAN boot server on the network you must upgrade the wanboot executable See Booting From a WAN Boot Server on page 29 for details Note For the latest information on supported firmware and software versions see Software Resources on page vii Solaris Patch Information The following patches are mandatory for Sun SPARC Enterprise M4000 M5000 servers running Solaris 10 11 06 OS These patches are not required for servers running Solaris 10 8 07 OS Note The patches include a revision level shown as a two digit suffix Check_ SunSolve Sun COM for the latest patch revision See Software Resources on page vii for information on how to find the latest patches Installing the Solaris Patches Install the following patches in numerical order 1 118833 xx minimum revision 36 Reboot your domain before proceeding 2 125100 xx minimum revision 10 See the patch README file for a list
37. ropdown menu and select Sun SPARC R Enterprise M4000 M5000 M8000 M9000 Servers Update Manager will analyze your system for any patches that are needed If patch 118833 xx is recommended select it by clicking the box to the left of the patch ID then click the Install button The patch will be downloaded to var sadm spool Note 118833 xx is a kernel patch that requires special instructions for installation see the patch README for specifics and therefore is a download only interactive patch requiring manual installation It is important to install patch 118833 xx first in order for any remaining patches in the patchset to be installed Continue by typing cd var sadm spool unzip 118833 xx jar Follow the installation instructions in the file var sadm spool 118833 xx README 118833 xx After installing 118833 xx restart the system Use the init or shutdown commands init 6 shutdown i6 Preface ix Note The reboot command does not complete installations of patches that require a restart Use either the Update Manager the init command or the shutdown command 7 Launch the Update Manager again and select the Enterprise Server collection 8 If the Update Manager does not automatically start a new analysis click the Check for Updates button 9 Select any patches that are listed by checking the boxes to the left of the patch IDs 10 Cl
38. rvice Fujitsu customers cannot enable service tags d Wait until XSCF firmware reaches the ready state This can be confirmed when the READY LED of the XSCF remains lit or the message XSCF Initialize complete appears on the serial console 12 Turn off all of the server s power switches for 30 seconds 13 After 30 seconds turn the power switches back on 14 Wait until the XSCF firmware reaches the ready state This can be confirmed when the READY LED of the XSCF remains lit 15 Log in on to the XSCFU using a serial connection or LAN connection 16 Confirm no abnormality occurred by using showlogs error v and showstatus commands XSCF gt showlogs error v XSCF gt showstatus If you encounter any hardware abnormality of the XSCF contact your authorized service representative Sun SPARC Enterprise M4000 M5000 Servers Product Notes 27 17 Power on all domains XSCF gt poweron a 18 Log in to the XSCFU and confirm all domains start up properly XSCF gt showlogs power 19 Check that there are no new errors XSCF gt showlogs error a Incase an abnormality is encountered contact your authorized service representative m If no abnormality is found proceed to Step 20 20 Move position of the key switch on the operator panel from Service to Lock Identifying Permanent Memory in a Target Board 1 Log in to XSCF 2 Type the following command XSCF gt sh
39. s 810mm 31 9 in for the Sun SPARC Enterprise M4000 M5000 servers TABLE 2 2 Midrange Servers Electrical Specifications See Electrical Specifications on page 15 in these Product Notes for the changes 8 1 3 Installing the PCI Cassette See Installing the PCI Cassette on page 5 in these Product Notes for the changes 11 2 DIMM Replacement See DIMM Replacement on page 5 in these Product Notes for the changes TABLE C 5 Power Supply Feature See Electrical Specifications on page 15 in these Product Notes for the changes 3 3 Connecting the Administration Console The RJ 11 connector at the top of Figure 3 1 was not labelled The RJ 11 connector is not for connection to TNV circuits Do not use this connector In Table 1 1 Main Unit Specification The following information will be added Architecture SPARCV9 architecture Platform groups sun4u Platform names SunW SPARC Enterprise 16 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 Software and Firmware Issues This section describes specific software and firmware issues and workarounds XCP Issues and Workarounds TABLE 7 lists known XCP issues and possible workarounds TABLE7 XCP Issues and Workarounds CR ID Description Workaround 6565422 The Latest communication field in Disabling and re enabling archiving refreshes showarchiving is not updated re
40. s licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc SPARC64 est une marques d pos e de SPARC International Inc utilis e sous le permis par Fujitsu Microelectronics Inc et Fujitsu Limited L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun Droits du gouvernement am ricain logiciel commercial Les utilisateurs du gouvernement am ricain sont soumis aux contrats de licence standard de Sun Microsystems Inc et de Fujitsu Limited ainsi qu aux clauses applicables stipul es dans le FAR et ses suppl ments Avis de non responsabilit les seules garanties octroy es par Fujitsu Limited Sun Microsystems Inc ou toute soci t affili e de l une ou l autre entit en rapport avec ce document ou tout produ
41. st but panic Correction 1 First execute the reset 8 command with the panic option from the XSCF Shell Solaris OS Software section The following Note has been added Note The XSCF firmware requires that all domains have the SUNWsckmr and SUNWsckmu u packages Since the Core System Reduced Network and Minimal System versions of the Solaris OS do not automatically install these packages you must do so on any domains that do not already have them Logging in to the System section Add the following Note Note In addition to the standard default login Sun SPARC Enterprise M4000 M5000 M8000 M9000 servers are delivered with a temporary login called admin to enable remote initial login through a serial port Its privileges are fixed to useradmin and cannot be changed You cannot log in as temporary admin using the standard UNIX user name and password authentication or SSH public key authentication It has no password and one cannot be added for it The temporary admin account is disabled after someone logs in as the default user or after someone logged in as temporary admin has successfully added the first user with valid password and privileges If before the default login is used you cannot log in as temporary admin you can determine if someone else has done so by executing the following command showuser 1 Audit Configuration add Note at the end of Audit File Tools Note This chapter describes how to set up a
42. t ou la technologie auxquels il se rapporte Par ailleurs il ne contient ni ne repr sente aucun engagement de quelque type que ce soit de la part de Fujitsu Limited ou de Sun Microsystems Inc ou des soci t s affili es Ce document et le produit et les technologies qu il d crit peuvent inclure des droits de propri t intellectuelle de parties tierces prot g s par copyright et ou c d s sous licence par des fournisseurs Fujitsu Limited et ou Sun Microsystems Inc y compris des logiciels et des technologies relatives aux polices de caract res Par limites du GPL ou du LGPL une copie du code source r gi par le GPL ou LGPL comme applicable est sur demande vers la fin utilsateur disponible veuillez contacter Fujitsu Limted ou Sun Microsystems Inc Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot et Sun Fire sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Fujitsu et le logo Fujitsu sont des marques d pos es de Fujitsu Limited Toutes les marques SPARC sont utilis es sou
43. tion to the standard default login Sun SPARC Enterprise M4000 M5000 M8000 M9000 servers are delivered with a temporary login called admin to enable remote initial login through a serial port Its privileges are fixed to useradmin and cannot be changed You cannot log in as temporary admin using the standard UNIX user name and password authentication or SSH public key authentication It has no password and one cannot be added for it The temporary admin account is disabled after someone logs in as the default user or after someone logged in as temporary admin has successfully added the first user with valid password and privileges If before the default login is used you cannot log in as temporary admin you can determine if someone else has done so by executing the following command showuser 1 30 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 TABLE9 Software Documentation Updates Continued Document Page Number Change Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF User s Guide Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers Administration Guide Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers Administration Guide Sun SPARC Enterprise M4000 M5000 M8000 M9000 Servers Administration Guide Page D 5 Page 2 Page 8 Page 66 Frequently Asked Questions FAQ in Troubleshooting XSCF and FAQ The option for OS dump is not reque
44. umentation Updates on page 30 Upgrading From XCP 104x to XCP 1050 or Later Note LAN connections are disconnected when the XSCF resets Use the XSCF serial connection to simplify the XCP upgrade procedure 1 Log in to the XSCF on an account with platform administrative privileges 2 Verify that there are no faulted or deconfigured components by using the showstatus command XSCF gt showstatus The showstatus prompt will return if there are no failures found in the System Initialization If anything is listed contact your authorized service representative before proceeding 3 Power off all domains XSCF gt poweroff a 4 Confirm that all domains are stopped XSCF gt showlogs power 5 Move the key position on the operator panel from Locked to Service Sun SPARC Enterprise M4000 M5000 Servers Product Notes 25 6 Collect an XSCF snapshot to archive the system status for future reference XSCF gt snapshot t user host directory 7 Upload the XCP 1060 upgrade image by using the command line getflashimage XSCF gt getflashimage http server domain com XCP1060 images FFXCP1060 tar gz The BUI on the XSCFU can also be used to upload the XCP 1060 upgrade image 8 Update the firmware by using the flashupdate 8 command Caution Flashupdate will update one bank reset the XSCF and commence update of the second bank Verify that the current and reserve banks are both
45. un SPARC Enterprise M4000 M5000 servers documentation set Solaris Operating System Solaris OS documentation is located at http www sun com documentation Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 part number 820 3612 10 xii Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 sun SPARC Enterprise M4000 M5000 Servers Product Notes This document includes these sections m Supported Firmware and Software Versions m Known Issues m Known Issues m Hardware Installation and Service Issues a Hardware Documentation Updates m Software and Firmware Issues m Software Documentation Updates Supported Firmware and Software Versions The following firmware and software versions are supported in this release a XSCF Control Package XCP 1060 or later m These servers support Solaris 10 8 07 OS or later m The first version of the Solaris OS to support these servers is the Solaris 10 11 06 OS plus patches See Solaris Patch Information on page 2 Caution CR ID 6534471 The system might panic or trap during a normal operation This bug has been fixed in Sola
46. ust after installing Solaris OS from a Solaris Sun SPARC Enterprise M4000 M5000 sun4u server and install it on a Sun SPARC Enterprise M4000 M5000 sun4u server the console s TTY flags will not be set correctly This can cause the console to lose characters during stress Flash archive telnet into the Sun SPARC Enterprise M4000 M5000 server to reset the console s TTY flags as follows sttydefs r console sttydefs a console i 9600 hupcl opost onlcr crtscts f 9600 This procedure is required only once 18 Sun SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1060 November 2007 TABLE8 Solaris Issues and Workarounds Continued CR ID Description Workaround 6508432 A large number of spurious PCIe correctable To mask these errors add the following entry errors can be recorded in the FMA error log to etc system and reboot the system set pcie pcie_aer_ce_mask 0x2001 This bug has been fixed in Solaris 10 8 07 6510861 When using the PCIe Dual Port Ultra320 SCSI Add the following entry to etc system to controller card SG X PCIE2SCSIU320Z a prevent the problem PCle correctable error causes a Solaris panic set pcie pcie aer ce mask 0x31c1 This bug has been fixed in Solaris 10 8 07 6511374 Memory translation warning messages might After the system is rebooted the fmadm appear during boot if memory banks were repair command may be used to prevent a disabled due to excessive errors recurrence of t